Mandatory Excel Spreadsheet.xlsx
XLSX spreadsheet 12 KB Posted
- Attached to
- HCC MEDICAL EQUIPMENT SERVICE AGREEMENTS
- Solicitation number
- 5400027197
- Issued by
- Charleston County, Charleston City, South Carolina
About this file
The provided document is a mandatory Excel spreadsheet detailing the requirements for a state and local contract opportunity for medical equipment service agreements in South Carolina, specifically in Charleston County and Charleston City. The contract includes service and maintenance for several pieces of specialized flow cytometry and tissue imaging equipment, such as the Beckman Coulter MoFlo Astrios cell sorter, the Cytek NL 3000 V/B/R-Premium, the Helios by Standard BioTools, and the Hyperion Tissue Imager. The contract covers a five-year term and includes requirements for preventative maintenance, technical support, and rapid response for service requests.
The pricing information provided outlines the expected costs for the various instruments and services over the five-year contract period. The contract opportunity is open to all qualified vendors, with no specific set-aside requirements noted. The current incumbent providers are not explicitly identified. Funding for this contract will be provided by the participating state and local jurisdictions, but the specific funding sources and amounts are not detailed in the provided documentation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Request for Proposal.docx | DOCX document | |
| Mandatory Excel Spreadsheet.xlsx | XLSX spreadsheet | |
| No Award.docx | DOCX document | |
| Request for Proposal.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Year One | Year Two | Year Three | Year Four | Year Five | Grand Total | Lot Total (Enter this 5 Year total in SCEIS for the Lot) | |
| Lot 1: Beckman Coulter | |||||||
| (1) MoFlo Astrios 1.1, Flow Cytometer Cell Sorter, Seial Number AZ02001, Inst. ID 21835280, Location 114 Doughty Street, Strom Thurmond Bldg. Charleston, SC, PT Protective Agreement with 2 scheduled PM's per year. | 5 | 5 | |||||
| (1) CytoFLEX LX, analyzing flow cytometer, Serial Number BD45318, |
Location: 173 Ashley Ave, Darby Children’s Research Institute, Charleston, SC Plan must include Instrument, workstation computer, CytExpert and related software, plate loader, WDM beam splitter, 6 lasers, cost of labor, travel and parts, one preventive maintenance and one health check per contract year, unlimited telephone support, reagents and applications provided at no cost, 48-hour response to a request for an emergency on-site service (Monday-Friday and excluding MUSC holidays).
| 5 | 5 | 10 | ||
| Lot 2: Cytex | ||||
| (1) Imagestream MKII, serial #ISX594 including the following installed components: Red Excitation Laser - 642 nm, 150 mW, 12 Imaging Channels & EDF, High Power Blue Excitation Laser Upgrade - 488nm, 400mW (at time of instrument purchase), Data Analysis Workstation w/2 TB RAID, dual 24 Monitors, INSPIRE and IDEAS Software 1 Seat License Pre-Installed, Violet Excitation Laser - 405nm, 120mW, MultiMag - 60X, 40X, and 20X (at time of instrument purchase), Green Excitation Laser - 561 nm, 200 mW, AutoSampler On-site service coverage of parts, labor and travel, One annual preventative maintenance calibration, Trained and authorized service technicians, Technical support services, End user training, Priority scheduling for service requests, Firmware and software updates. | 0 | |||
| (1) Cytek NL 3000 V/B/R-Premium (RUO) Product # N9-90143, Serial Number N0814- Includes 2 preventive maintenance inspections per year; all lasers, non-consumable parts, Spectroflo and related software, travel, and labor for repair visits; 24-hour (maximum) response time for technical support and 48-hour (maximum) response time for non-functional instruments, with escalation to the top of our priority field service job queue; on-site and remote assistance, including assistance with panel design, data analysis, assay optimization and troubleshooting, and general scientific consultation; unlimited telephone technical support. | 0 | 0 |
| Lot 3: Standard BioTools | ||
| (1) Helios Serial # D16-0164 -must include repair parts (including detectors, software, and workstation computer), labor, and travel. Unlimited technical support, with extended hours available to select markets. Targeted onsite service response within two (2) business days. One annual onsite preventive maintenance (PM) visit including one Essentials PLUS consumable parts kit. Free shipping on consumable parts. | 0 | |
| (1) Hyperion Tissue Imager (HTI) Serial #1080010120H preventive maintenance (PM) in addition to repair and support. Includes repair parts, labor, travel, and unlimited technical support. Targeted onsite service response within 3 business days. One annual onsite PM visit. Laser coverage included. | 0 | 0 |