100% Submittal (Revised)
FACILITY SUSTAINMENT, RESTORATION, AND MODERNIZATION (FSRM) PLANNING
CHARRETTE REPORT (CCR)
Repair Stennis Hall B1002 (100% Submittal)
Keesler AFB, Biloxi, MS
MAHG171095
06/18/2021 (Revised 8/23/2021)
Civil Engineering
Point of Contact:
George Reed, AIA 228-377-5823 george.reed.6.ctr@us.af.mil mailto:george.reed.6.ctr@us.af.mil
1.0 Introduction
This document provides the Facility Sustainment, Restoration, and Modernization (FSRM) Planning Charrette Report (CCR) for the Repair Stennis Hall B1002 project at Keesler AFB, Biloxi, MS.
The primary purpose of the CCR is to develop a project scope and costs as well as to provide conceptual design programming documentation in preparation for possible submission for project approval; DD Form 1391. It also provides the designer a basis for understanding the project requirements and establishes a framework for project execution.
The PCR development was accomplished by Allred Stolarski Architects, PA. Key participants included in developing this document included:
Major Vernise Hunter – 333rd TRS Major Rosa Koenig – 333rd TRS Claudette Johnson – 333rd TRS 2nd Lt. Joseph Goddard – 333rd TRS James Neal – 333rd TRS Ted Dyer – KAFB 81st CES Nicky Brown – 81st TRSS Curtis Rucker – 81st TRSS Tony Jo Matheu – 81st CS Michael Harshbarger – KAFB BOS/CGOH
Mark Groves – KAFB BOS/CE Charles Yates – KAFB BOS/CE George Reed – KAFB BOS/CE Doug Walker, PE - KAFB BOS/CE John Stolarski, AIA – Allred Stolarski Architects Chad Moore, PE – Engineering Resource Group Travis James – Engineering Resource Group Greg Wyrosdick – Welcon Electrical Consultants Michael Costelli – Simpkins & Costelli Maddie Pettry – Simpkins & Costelli
The project scope and costs are described below and in the Appendix. The Form 1391 is provided in Appendix A.
The following is a summary of the basic project information:
Project Name: Repair Stennis Hall B1002 Project Number: MAHG171095 Installation: Keesler AFB Requiring Command: AETC Host Command: AETC Fiscal Year (FY) Planned: FY23 Category Code(s): 171-623 Proposed Acquisition Method: DBB Status of Design: Unfunded A&E Design requirement Design Agent: Base Construction Agent: Base
2.0 Project Description
2.1 General Description
Stennis Hall (B1002) is a 113,800 SF two story facility with concrete and steel structure that has been in use for over 35 years. Through its service, the facility has had mission areas and functions adjusted through a series of renovations. The main function of the building is to provide both officer and enlisted cyberspace training and skills development. In addition, the facility users are responsible for overseeing the development and advancement of this technical training for all Air Force operations across the globe. The facility is comprised of numerous training classrooms, with both recess and above slab access computer flooring, offices, conference room, auditoriums/briefing room, data center, communications rooms and mechanical & electrical areas. The building is divided in to secure and non-secure areas with like kind spaces in each area.
It has been reported and documented prior to this contract that the HVAC has had several renovations over the years. It is evident that each renovation did not address or correct issues from previous renovations which has caused some areas to be under served. Additionally, major portions of the system have outlived their service life, specifically the chillers and pumps. A new cooling tower was recently installed. However, a new generator project already planned for the facility will not serve the HVAC which leaves the facility sensitive equipment in danger of overheating, especially in the Data Center. Computer Room A Conditioning (CRAC) units are utilized in all classroom and some current office areas. Some units have been abandoned, and in other locations, some have been removed without replacing their supplemental volume. Multiple HVAC, Electrical and Fire Protection system renovations over the years require as-built assessment to be pieced together several decades of drawings. Additionally, several of the previously mentioned renovations abandoned utilities in place such as fire suppression, electrical conduit and cable, piping and ductwork.
The Users wish to provide the students with an updated, functional facility in line with their technical mission. At present, the non-secure areas contain several classroom and office spaces that appear to be under-utilized and/or for catch-all storage.
The facility is centrally located on the Base, on block to the east of the flight line. See Figure 01, Vicinity Map, for location of the project site. See Figure 02, Project Site Map, which illustrates the project site location and surrounding area. Documentation photographs of the existing facility are included in Appendix C of this document.
2.2 Current Situation
Due to COVID protocols, the facility is currently being lightly used by Airmen with several students, Officers and staff working virtually. The facility houses a new class of airmen every two weeks. When the facility is at full capacity with current class loads, that are up to 500 people in the building at once (250 per floor). However, per current code, the occupant load of the building is over 700 occupants. With the training program estimated to grow to exceed 1,000 students, utilization of all areas of the facility will need to be achieved to house all students and faculty. Scheduling of facilities will need to be reviewed as well to stagger occupancy over the course of the day.
The HVAC system is a four-pipe system with two 315-ton chillers and two recently replaced cooling towers. Heating of the facility is provided by two 725 MBH Boilers which were installed within the last five years. Supplemental cooling in raised access floor classroom and office spaces is provided by CRAC units also connected to the chill water loop. The system does not appear to be balanced with regard to total hvac loading of the building. It is a possibility that the supplemental air provided is keeping the main hvac system from operating at full efficiency. The building is not accessible with regards to accessible routes, drinking fountains or restroom accommodations.
2.3 Impact if Not Provided
If the facility remains in its existing condition, the building will continue to use excess energy due to its inefficient building systems, yet still be an uncomfortable building to occupy.
Additionally, the inability to adequately condition the Data Center if one of the existing chillers malfunctions or if the facility faces a power outage could potentially be detrimental to the mission of the facility and its occupants. Handicapped accessibility to the facility remains a liability if left unaddressed.
2.5 Cost Estimate
The cost estimate herein has been developed using historical bid data of recent projects of similar scope and complexity. In addition, we have utilized current RS Means online estimating/pricing data to cross reference unit costs. To be conservative, the regional modifiers was not utilized or considered in the development of the estimate. Additionally, it is noted that this project will require Davis-Bacon wage rates.
2.6 Concept Sketches
The drawings included in Appendix B document the existing condition floor plans and elevations of Stennis Hall. Additionally, conceptual demolition floor plans and renovation floor plans and elevations are provided. The conceptual design presented shall be in accordance with AFAN 32-1084; more specifically AFRS Cat Group 17 – CC171621 Technical Training Classrooms and the Controlled Facility Guidance DoDM 5105.21-V2 & ICD/ICS 705 Tech Specs. Repairs and renovations to the facility will comply with UFC’s 01-200-01, 01-200-02 and AFI 32-1020.
FIGURE 01: VICINITY MAP
FIGURE 02: PROJECT SITE MAP
STENNIS HALL (B1002)
3.0 Scope Analysis
3.1 Cost and Scope Thresholds
Item Value Remarks Project Program Amount
(PA)
$5,200,000 Report PA per AFI 32-1032
Maintenance EEIC 521xx
$0 No work in this classification
Repair (Sustainment) EEIC 524xx
$5,200,000 Partial replacement & upgrades to existing HVAC, Plumbing, Electrical & Comm Systems, Upgrade flooring & finishes, renovate restrooms to meet accessibility requirements, renovate building entrance areas to meet accessibility requirements.
Repair (Restoration & Modernization) EEIC 522xx
$0 No work in this classification
Minor Construction EEIC 529xx
$0 No work in this classification
Plant Replacement Value
(PRV)
$45,885,566 Per 1391
PA / PRV ratio 11.3% Ratio is below 50%
Estimated Replacement Cost (ERC)
$45,250,000
PA / ERC ratio 97% Existing Building Area, Gross
113,800SF
Size of Addition, Gross N/A N/A Addition/Existing Ratio N/A
3.2 User and Facility Requirements
Requirements Remarks
GENERAL
As-Built Drawings As-built drawings of the original building and subsequent renovations have been provided for reference. Accuracy of as-built drawings vary from conditions in the field in some areas with regards to HVAC and Fire Protection. Documents have been helpful in documenting the facility and developing conceptual drawings.
Site Accessibility Concerns
Contractors/Sub-contractors will be required to gain access to Base to complete this Work. Additional time will be required in General Conditions to administer/gain base access for workers.
Construction Security Contractors/Sub-contractors will be required to gain access to Base as well as obtain secure area clearance to complete this Work.
Additional time will be required in General Conditions to administer/gain base access for workers. Site laydown will need to be completely fenced in during construction.
Temporary user space/ Project phasing
There is no additional space on Base for users to utilize during construction that allows their mission to continue. Project will require detailed phasing to allow users to remain running on one floor while the other floor is renovated and vice versa.
Facility Addition N/A
Allied Support Requirements
N/A
SITE, CIVIL, AND
GEOTECHNICAL
Existing Site Conditions Existing site conditions consist of an open grassed landscape perimeter with existing mature trees and shrubs adjacent to building, concrete sidewalks and pavement adjacent to the existing building with users parking to the east of the facility. Mechanical equipment is located at the southeast corner of the building on elevated steel frames.
Facility Siting Site laydown will need to be completely fenced in during construction.
Removals/Demolition Concrete walkways leading to entrances, especially off the east parking shall be removed and replaced to meet ADA guidelines.
Geotechnical Report N/A
Special soil conditions N/A
Roads and Drives N/A
Vehicle Parking Relocate north ADA parking spaces to be grouped on south side of main building entrance and level out asphalt parking in this area.
Site Work Concrete walkways leading to entrances, especially off the east parking shall be removed and replaced to meet ADA guidelines. A new concrete access ramp is to be installed to provide accessible access to the building.
Grading & Storm Water There are no known drainage issues based on reports received by base personnel in the project kickoff meeting.
UTILITIES
Water Distribution No known work to site utilities currently, nor is any anticipated.
Sanitary Sewer No known work to site utilities currently, nor is any anticipated.
Natural Gas No known work to site utilities currently, nor is any anticipated.
Electrical. Lighting, Communications, Fire Alarm, and Generator/UPS
There is (1) existing medium voltage transformers which service the facility at 480/277 volt, and several dry-type transformers throughout the facility that provide power for receptacle and miscellaneous loads at 120/208 volt. The site utility transformer appears to be in satisfactory shape and appropriately sized for renovation scope of work. It is anticipated this transformer will remain for the renovation project, but further investigation will be performed to verify size and conditions.
Exterior Communications N/A
Cathodic Protection N/A
ARCHITECTURAL
REQUIREMENTS
Air Force Corporate Facility Standards (AFCFS)
Exterior upgrades to fenestration and materials shall be in keeping with the vernacular materials in use and as described in the Keesler Air Force Base design standards.
Air Force Standard Designs
Air Force Corporate Facilities Standards and Standard Designs shall be incorporated into the final design wherever possible and/or applicable.
Installation Facilities Standards (IFS)
Keesler Air Force Base Design Standards
Space Requirement Analysis
The conceptual design presented shall be in accordance with AFI 32-1084; more specifically AFRS Cat Group 17 –
CC171621.
Finishes (exterior walls, interior walls, ceilings)
Existing exterior structure finish is precast exposed aggregate concrete panels. Panel joint sealants and backer rod are recommended to be replaced. This scope is not included in the 1391 project scope so therefore should be looked at being addressed in a separate project.
SECURE AREA Existing secure areas in use have been modified and expanded over the facilities history. A review of the construction of the perimeter of these areas and their building systems will be conducted to ensure the spaces meet UFC 4-010-05, AFRS Cat Group 17 – CC171621 Technical Training Classrooms and the Controlled Facility Guidance DoDM 5105.21-V2 & ICD/ICS 705 Tech Specs.
There are no restrooms are within the secure area of the facility. Users within the secure area must exit the secure area to use the restroom. It was proposed to renovate two restrooms on each floor to provide access to restrooms from the secure areas. Janitorial service to these areas would need to be escorted with the same SOP utilized at McClellan Hall.
This scope is not included in the 1391 project scope so therefore should be looked at being addressed in a separate project.
Perimeter walls of the secure areas are to be fully assessed against the above guidance to meet the construction of “Wall A – Standard Acoustic Wall” and renovated where needed to comply. Similarly, any HVAC penetration shall be renovated to meet the requirements of a “Typical Perimeter Air (Z) Duct Penetration”. Penetrations are to be kept to a minimum. Additionally, walls are to be renovated to meet Radio Frequency (RF) Protection.
Sound Attenuation Sound attenuation ducting shall be used in the large halls.
Elevators The existing elevator has hydraulic leak and parts are difficult to obtain.
The elevator shall be refurbished in keeping with current base standards.
Correction of Architectural Barriers Act (ABA) Deficiencies
Several entrance thresholds need to be corrected to provide access into building, be it by adding new thresholds or providing a ramp/landing at exterior entrances. None of the existing restroom facilities fully meet ADA/ABA. Computer Access Flooring on slab should be removed to eliminate 6” step into these spaces to make classrooms accessible to all users.
State Historical Preservation Office Review
Stennis Hall does not appear in a search of the MDAH and National Landmark listings.
STRUCTURAL
Foundation Existing structure is a two story, concrete and steel framed building on shallow foundations. No evidence of settlement was noted at initial inspection.
Roof The existing acrylic fluid applied roof system is to remain.
Structure New accordion partitions will be installed between several classrooms requiring supplemental steel framing above to existing structure for support.
- Modification/increase in loads
No additional roof loads are anticipated at this time.
- Structural Repairs No significant repairs are known to exist at this time; minor structural repairs due to new work will be encountered.
- Seismic Evaluation Required
UFC 3-310-04 was cancelled in 2016 and IBC 2015 was adopted.
Stennis Hall is a Risk Category III for an (assumed) Site Class D and a Seismic Design Category B and is therefore, is exempt from replacement or evaluation.
MECHANICAL &
PLUMBING SYSTEMS
It is recommended that the existing mechanical and plumbing systems be replaced in their entirety (except the two cooling towers, two condensing boilers, and potentially Variable Air Volume (VAV) boxes).
System equipment and components are in poor condition and beyond their service lives.
It is recommended that the new air distribution systems be comprised of high-performance VAV air distribution systems.
It is recommended that both 315 centrifugal chillers be replaced. Size shall be confirmed during the design phase. The chilled water distribution system including pumps and piping is recommended to be replaced.
There are two (2) new existing cooling towers that are in excellent condition and recommended to be remain. The capacity of the existing cooling towers will be evaluated based on the cooling load calculations to confirm they have adequate capacity.
The facility heating has by two (2) existing 725 MBH boilers that have a manufactured date of 2017 Boilers appear to be in good condition and should be considered for reuse. The heating water distribution system including pumps and piping is recommended to be replaced.
An analysis will be conducted to determine if the existing Computer Room Units serving the training classrooms can be removed and served by the new DX stand-alone air distribution system.
It is recommended that the Computer Room Units serving the existing data center be replaced.
The existing Energy Management and Control System (EMCS) was recently upgraded. It is recommended that all EMCS components be remain and any system upgrades/renovations utilize this system to the greatest extent practicable.
All drinking fountains are recommended to be replaced with non-filtered, ADA compliant “hi-low” fountains with bottle fillers.
HVAC system or component modifications
The following HVAC systems are recommended to be replaced.
• Water cooled chillers.
• Chilled water pumps, converted to a primarily-only variable flow system.
• Chilled water piping system.
• Heating water pumps, converted to a primary-only variable flow system.
• Heating water piping system.
• VAV Air Handling Units (AHUs). Replace with new unis and incorporate the ASHRAE Guideline 36-2018 sequences of operation.
• Computer room unit serving the existing data center.
Replace VAV boxes as they are original to the building. Some existing locations may be relocated/repositioned to maximize access for maintenance purposes.
- Unusual ventilation N/A
- Special heating/cooling loads
IT/Comm and Data Center spaces will be provided with dedicated HVAC systems to provide 24/7 operation.
- Temp/humidity control Building temperature and humidity control will be provided by the new VAV systems. VAV air distribution systems inherently provide superb humidity control when controlled in conjunction with the building pressure and space temperature.
The HVAC systems will be designed to maintain the indoor conditions as specified in UFC 3-410-01.
Plumbing system or component modifications
All plumbing fixtures are recommended to be replaced. Low water consumption fixtures will be specified.
FIRE PROTECTION
REQUIREMENTS
The existing fire suppression system is an automatic wet pipe fire sprinkler system in accordance with UFC 3-600-01. A Fire Protection Design Analysis should be conducted to determine the required updates and fire sprinkler system modifications. The analysis will consider the existing sprinkler system and all modifications made to the protected areas. Sprinkler system performance requirements will be determined based on hydraulic analysis of water demand. This scope is not included in the project 1391. Should fire protection renovation be deemed necessary, the PA for this project will need to be revisited.
Category of Work The existing automatic wet pipe fire sprinkler system will be modified in accordance with UFC 3-600-01.
Fire Safety Deficiencies (FSDs)
And Corrective Action Plans (CAPs)
Existing utilities are to be shut-off and/or purged prior to demo.
Contact the base fire department for hot works permits. Obtain signed dig permits prior to work. Notify base fire department of any blocked access areas All contractor workers shall be knowledgeable of Keesler Emergency procedures. Notify base fire department when project construction is complete for site visit and any document signatures.
Contractor shall notify/request Vectrus sprinkler and fire alarm technicians perform final check-outs, including applicable sprinkler hydrostatic testing. All current fire and life safety UFC’s/NFPA’s/AFI’s codes shall be applicable and followed.
Changes to facility egress N/A
Changes to occupant density
Proposed changes will not change intended use of the spaces.
However, due to new codes the occupant loading will increase significantly from 1985 design.
Facility houses Mission- Support or Mission- Essential Equipment
This facility does not contain equipment that would trigger any additional fire protection requirements per ETL 01-18.
Hangar N/A
ELECTRICAL SYSTEMS
Primary Power Services The existing electrical service laterals appear to be the original installation. The main electrical room houses the largest electrical service equipment, and there are electrical rooms located in all quadrants of the building on each floor. There are motor control centers (MCCs) in larger mechanical rooms to provide electrical service for pumps and mechanical equipment. The “quadrant” electrical rooms have 480V panels servicing equipment, each has (1-
2) dry-type transformers, and (1-2) 120/208V panels. In addition, there are numerous 120/208V distribution panels in all quadrants of the building, which provide service feeders for 120/208V branch panels in many of the classrooms. The new design will replace all incoming service laterals for the electrical service entrance into the main electrical room. Branch service distribution will be reviewed and will remain where adequate. Many of the existing panels are an obsolete series and were installed as part of the original building construction. These panels will be replaced. Existing dry-type transformers will be reviewed for size, age, and function.
Transformers will be replaced as deemed necessary or where they have reached their useful life expectancy. 120/208V sub panels will be added where necessary to accommodate additional branch circuits in classrooms.
Interior Electrical Many of the classrooms will receive additional branch circuits to accommodate additional computer stations to allow for 5 cpu’s per station. New receptacles will be added where necessary for additional workstations or convenience power.
Communications systems for the entire facility will be reviewed and coordinated with the end users. There are currently a minimum of (5) networks being used in the classrooms and throughout the facility.
Lighting Existing lighting throughout the facility is generally all new LED and was recently replaced during renovation. All existing areas that did not have lighting previously upgraded, will receive new LED lights.
Lightning Protection The existing facility does not appear to have any lightning protection systems. New design will include proper grounding for the electrical service, lightning protection, communications systems, building steel, water service entrance pipes, etc. as required. Transient Voltage Surge Suppression units will be included throughout all electrical systems to protect sensitive equipment. This scope is not included in the project 1391, the PA for this project will need to be revisited to include this scope.
RPIE Generators The existing facility has a small generator that provides power for life safety and security system only. Adding a new generator is recommended to provide backup power for HVAC units in critical comm areas and network equipment rooms in support of the buildings mission. The new unit should be sized to allow for the systems to run long enough to allow for proper shutdown at a minimum. At a minimum, the power system should be renovated to allow for the connection of a temporary genset trailered to the building exterior with an manual transfer switch. Additionally, an uninterruptable power source (UPS) for all computer networks was discussed to be added to the facility in the future. This scope is not included in the project 1391, the PA for this project will need to be revisited should this scope be deemed necessary to be included in this project.
Special user requirements N/A
ANTITERRORISM /
FORCE PROTECTION
Current number of occupants: 500 (reported) Current occupancy level: Primary Gathering Planned number of occupants: 1,000 (anticipated) Planned occupancy level: Primary Gathering
UFC 4-010-01
Antiterrorism Minimum Standards; project scope requires full mandatory compliance
No ATFP triggers are met with this renovation. Renovation ratio is well below 50% and Occupancy does not change. ATFP upgrades are not required for this project.
- Unique Occupancy Factors
N/A
- Standoff Distances N/A
- Window or Glazed Door Replacement
N/A
- HVAC replacement or upgrade
Emergency shut-off switches for the HVAC system, per UFC 4-010-0;
ATFP Section 3-19, located such that the travel distance to the nearest shutoff switch shall not be in excess of 200 ft. Shutoff switch shall be well labeled and of a different color than the alarm pull station.
The low leakage dampers will have maximum leakage rates of 3 cfm/square foot and will be located at the building envelope as close as possible. Outside air intake shall be a minimum of 10’ above adjacent grade.
- Mass Notification System (MNS)
Fire Alarm systems and mass notification systems have been recently replaced throughout the facility. Existing fire alarm systems will remain.
Antiterrorism or Force Protection Requirements beyond Minimum AT Standards
N/A
SUSTAINABILTY
UFC 1-200-02, HPSB
Requirements
Project shall be designed to meet all applicable UFC directives, as well as IBC 2018 and current energy codes.
Compliance with AF SDD Implementing Guidance Memorandum
This project shall be designed to comply with the AF SDD Implementing Guidance memo.
Third-Party Certification N/A
ENVIRONMENTAL
REQUIREMENTS AND
HAZARDOUS
SUBSTANCES
Environmental Permitting Required
New generator to be installed will require an air permit modification.
Hazardous Materials Remediation
N/A
Environmental Impact Analysis Process (EIAP)
DESIGN AND
ACQUISITION OF
UNFUNDED
Furniture Fixtures and Equipment (FF&E) Acquisition
N/A
Existing FF&E Reuse N/A
Non-RPIE Communications Acquisition
Design to provide conduits and cabling. Base IT to complete terminations and installation of devices, switches, racks…etc.
Non-RPIE Generators/UPS/other backup power storage or capability
N/A
Raised Access Flooring Existing above slab raised access flooring is to be removed and new flooring to be installed on slab. Existing recessed access flooring is to remain.
TEMPEST / HEMP / RF
Shielding
All cabling installed is to be shielded.
Intrusion Detection Systems (IDS)
Existing intrusion detection system is to remain.
Closed Circuit TV N/A
Other User Equipment, Including Special Computer Systems or Support
Existing computer systems are to remain.
3.3 User Equipment
3.4 Hazardous Substances
Hazardous Substances Y / N / Unknown
Remarks (date of last survey)
Asbestos N Lead Based Paint N
PCB N
Radon N IRP Sites N Toxic industrial waste N Radiological N Heavy Metals N Ozone Depleting Substances (refrigerants)
N
Medical gases N
Known Abatement Considerations Y / N /
Unknown Remarks
Asbestos N Lead Based Paint N
PCB N
Radon N Hazardous Waste (RCRA) N Heavy Metals N Aqueous Film-Forming Foam (AFFF) N
3.5 Approvals/Exemptions/Waivers
APPENDICIES
A. DD Form 1391 Draft and 100% Cost Estimate B. Flood Map of Keesler Air Force Base C. Existing Conditions, Demolition and Renovation Floor Plans and Existing Elevations
APPENDIX A:
DD Form 1391 Draft and Cost Estimate
DD FORM 1391, DEC 99 Previous editions are obsolete Page No 1
1. COMPONENT
AETC
FY 2023 PROJECT DATA
2. DATE
3. INSTALLATION AND LOCATION
KEESLER AIR FORCE BASE
KEESLER AFB SITE #1
MISSISSIPPI
4. PROJECT TITLE:
REPAIR STENNIS HALL B.1002
5. PROGRAM ELEMENT
22178
6. CATEGORY CODE
171-623
7. PROJECT NUMBER
MAHG171095
8. PROJECT COST ($000)
$5,200
9. COST ESTIMATE
ITEM UOM QTY UNIT
COST
COST ($000)
PRIMARY FACILITIES
REPAIR
ARCHITECTUAL SF 60,000 $24.80 $1,488
ELECTRICAL SF 60,000 $8.27 $496
MECHANICAL SF 115,000 $22.78 $2,620
DEMOLITION SF 60,000 $5.93 $356
PLUMBING SF 2,173 $23.01 $50
ELEVATOR REPAIR SF 59 $1,525.42 $90
CYBERSECURITY (2.5%) LS $115
Total Primary Facility Repair Cost $5,125
Sub Total REPAIR $5,215
TOTAL REPAIR (Rounded) $5,200
TOTAL PROJECT COST [match block 8] $5,200
Design-Bid-Build Design Costs 6% $312
This project will be executed as a Design Bid Build project. Project is not designed.
This estimate is based on a 0% complete design as of 2020.
Note: This project is planned for execution in FY 2023. Costs as shown represent an escalation factor of 1.08% per year from FY2020 costs.
8/23/2021
DD FORM 1391, DEC 99 Previous editions are obsolete Page No 2
AETC
FY 2023 PROJECT DATA
2. DATE
3. INSTALLATION AND LOCATION
KEESLER AIR FORCE BASE
KEESLER AFB SITE #1
MISSISSIPPI
4. PROJECT TITLE:
REPAIR STENNIS HALL B.1002
5. PROGRAM ELEMENT
22178
6. CATEGORY CODE
171-623
7. PROJECT NUMBER
MAHG171095
8. PROJECT COST ($000)
$5,200
10. DESCRIPTION OF PROPOSED WORK: REPAIR
Repair finishes, HVAC, plumbing fixtures, and electrical demands in the entire facility. Remove and replace existing chill water pump and piping; return and make-up air dampers for air handling units; supply and return ducts, registers, and grilles to match existing interior layout of the building. Install re-heat piping, VAV boxes, and Direct Digital Controls to provide adequate temperature and humidity conditions to standards. Rework all bathroom facilities, replace interior finishes, including carpeting where necessary, acoustical ceilings, lighting fixtures and electrical supply for technical classrooms. Repair elevator and elevator equipment. Facility is a permanent constructed facility and will comply with the DoD Unified Criteria (UFC) 1-200-01, General
Building Requirements. Sustainable principles, to include life cycle cost-effective practices, will be integrated into the design development, and construction of the project in accordance with UFC 1-200-02.
11. REQUIREMENT
A facility that promotes efficient year long educational training. Stennis Hall is a cyber training facility for secure activities. The facility must provide sufficient conditioned space to accomplish training mission.The space must be climatically conducive to learning and must support heat sensitive equipment, including, CPUs, Laptops, printers, monitors and other heat sensitive equipment. Repairs to the facility are not tenant driven and will comply with AFI32-1020. .
CURRENT SITUATION & IMPACT
Stennis Hall has been modified many times in the past few years in order to accomodate the rapidly increasing requirement for
Cyber Training. While attempts have been made to provide appropriate space the original HVAC equipment was not designed for the heat load requirements of today's clssroom.Temperatures are not only not conducive to learning equipment needs and it is becoming increasingly difficult to keep the equipment operating efficiently. Cyber Ops classes in Stennis are delayed when servers and equipment fail due to high temperatures from inadequate HVAC. A chiller failed two times in CY18 which impacted eight classes of 16 students per class HVAC maintenance costs doubles between CY17 and CY18 from $12,600 to $28,013. The average student population is 250 students but the population of students is project to increase to a 1000 students by FY21. Facility system failures will continue to affect the student Airmen education. To replace the entire facility, construction cost is estimated around
$45,885,566. Repairs and renovation to the facility is about 11% of the replacement cost.
PROJECT
This project is to achieve a modern and updated facilty to promote learning and training for student airmen all year long. The students located in this facility must be provided with an area to properly train with secure activities. The improved facility will also be able to handle an increased student population which was significantly different when the facility.
ADDITIONAL
PROJECT COST: $5,200
SOURCE OF FUNDS: O&M
CONSTRUCTION AREA COST FACTOR: 0.96
PRICING DATA SOURCE: RS Means Cost Database 2020
EXECUTION AGENT: 81 CONS
ESTIMATED MILCON REPLACEMENT COST: $64,239,792
REPAIR-TO-REPLACEMENT RATIO: [$5,200/$64,240 =8%]
PLANT REPLACEMENT VALUE (PRV): [$45,885,566]
REPAIR-TO-PRV RATIO: $5,200/$45,886 =11%, used only for the AT compliance metric
REPAIR-TO-REPLACEMENT RATIO:
The total funded cost of $5,200 is 8% of the $64.2M estimated cost of a MILCON project to replace the facility.
In accordance with AF/A4C guidance, this repair project replaces less than 75% of the networked facility
COMPLIANCE STATEMENTS
DD FORM 1391, DEC 99 Previous editions are obsolete Page No 3
AETC
FY 2023 PROJECT DATA
2. DATE
3. INSTALLATION AND LOCATION
KEESLER AIR FORCE BASE
KEESLER AFB SITE #1
MISSISSIPPI
4. PROJECT TITLE:
REPAIR STENNIS HALL B.1002
5. PROGRAM ELEMENT
22178
6. CATEGORY CODE
171-623
7. PROJECT NUMBER
MAHG171095
8. PROJECT COST ($000)
$5,200
SEISMIC RULE:
Compliance with the seismic 30% repair-to-replacement ratio is not required. The scope of this project complies.
Compliance with the seismic 50% repair-to-replacement ratio is not required. The scope of this project complies.
ANTITERRORISM (AT) RULE:
Compliance with the AT 50% repair-to-PRV ratio is not required.
FIRE PROTECTION RULE:
Compliance with the 50% Fire Protection Rule is not required.
ECONOMIC ANALYSIS (EA) RULE:
This project’s programmed amount does not exceed both $2M and 75% of the estimated cost of a military construction project to replace the facility, therefore an economic analysis of alternatives is not needed.
FLOODPLAIN MANAGEMENT RULE:
This project does not fall within or partly within a 100-year flood plain.
STANDARD DESIGN:
This design shall conform to criteria established in the Air Force Corporate Facilities Standards (AFCFS), the Installation
Facilities Standards (IFS), and shall employ the standard facility design
RENTED OR LEASED FACILITY:
The facility in this project is not a rented or leased facility.
CERTIFICATION: I have reviewed this document and certify it is complete and accurate, and is compliant with appropriate statute(s) and instructions. I have validated the project’s primary and supporting costs and work classification. It has been fully coordinated with the user and other appropriate agencies and approved by the Installation Facility Board.
Robert T. Moseley III, GS-14, DAF
Deputy Base Civil Engineer, 81st Civil Engineer Squadron
Base Civil Engineer, Keesler AFB
(228) 377-9019
Repair Stennis Hall Keesler Air Force Base - Biloxi Mississippi 100% Planning Charette Estimate August 23, 2021
QUANTITY UNIT UNIT PRICE TOTAL PRICE
DIVISION 1 - GENERAL REQUIREMENTS
Selective Demolition 113,800 S.F. $1.00 $113,800.00 Contractor General Conditions 18 Months $15,000.00 $270,000.00 Total 1 $383,800.00
DIVISION 2 - SITE WORK
None in this project
DIVISION 3 - CONCRETE
None in this project
DIVISION 4 - MASONRY
None in this project
DIVISION 5 - METALS
Metal Stud Framing 3,250 L.F. $25.00 $81,250.00 Total 5 $81,250.00
DIVISION 6 - WOOD & PLASTICS
Rough Carpentry 1 L.S. $60,000.00 $60,000.00 Finish Carpentry & Millwork 1 L.S. $120,000.00 $120,000.00 Total 6 $180,000.00
DIVISION 7 - THERMAL AND MOISTURE PROTECTION
Ceiling Sound Batts 113,800 S.F. $0.80 $91,040.00 Total 7 $91,040.00
DIVISION 8 - DOORS & WINDOWS
Finish Hardware
Exterior 8 Leaf $750.00 $6,000.00 Interior 5 Leaf $300.00 $1,500.00
Total - 8 $7,500.00
DIVISION 9 - FINISHES
Porcelain Ceramic Tile 4,250 S.F. $13.00 $55,250.00 Gypsum Board At Walls 350 S.F. $2.00 $700.00 Gypsum Board At Ceilings 1,500 S.F. $4.00 $6,000.00 Suspended Acoustical Ceiling Tile 113,800 S.F. $4.00 $455,200.00 Luxury Vinyl Tile 23,250 S.F. $8.00 $186,000.00 Static Dissipative Tile 10,500 S.F. $13.50 $141,750.00 Rubber Wall Base 5,000 L.F. $1.50 $7,500.00 Ceramic Tile Base 500 L.F. $10.00 $5,000.00 Stair Treads 1,200 L.F. $30.00 $36,000.00 Carpet 4,100 S.Y. $36.00 $147,600.00 Paint/Stain - Walls 200,000 S.F. $1.00 $200,000.00
Ceilings 5,000 S.F. $1.00 $5,000.00 Ext. HM Doors/Frame 5 EA. $125.00 $625.00 Int. Doors/Frame 150 EA. $90.00 $13,500.00
Total - 9 $1,260,125.00
DIVISION 10 - SPECIALTIES
Toilet Stalls 40 EA. $1,000.00 $40,000.00 H/C Toilet Stalls 8 EA. $1,000.00 $8,000.00 Fire Extinguishers 40 EA. $85.00 $3,400.00 Fire Extinguisher Cabinets 40 EA. $300.00 $12,000.00 Identifying Devices 1 L.S. $40,000.00 $40,000.00 Toilet Accessories
Mirrors 40 EA. $100.00 $4,000.00 Soap Disp. 70 EA. $90.00 $6,300.00 T.P. Holders 70 EA. $45.00 $3,150.00 P.T. Disp. 20 EA. $80.00 $1,600.00 Waste Recp. 20 EA. $195.00 $3,900.00 San. Nap. Disp. 20 EA. $375.00 $7,500.00 San. Nap. Recp. 20 EA. $175.00 $3,500.00 Coat Hooks 80 EA. $22.00 $1,760.00 Mop Holders 4 EA. $80.00 $320.00
Total -10 $135,430.00
DIVISION 11 - EQUIPMENT
None in this project
DIVISION 12 - FURNISHINGS
None in this project
DIVISION 14 - CONVEYING SYSTEMS
Passenger / Service Elevator (Refurbish Existing) 1 EA. $35,000.00 $35,000.00 Total -14 $35,000.00
DIVISION 15 - MECHANICAL
Plumbing Demolition 113,800 S.F. $0.15 $17,070.00 Plumbing Mobilization 1 L.S. $40,000.00 $40,000.00 Water Closets 30 EA. $1,000.00 $30,000.00 Urinals 20 EA. $1,000.00 $20,000.00 Lavatories 50 EA. $900.00 $45,000.00 Sinks 4 EA. $700.00 $2,800.00 Drinking Fountains (w/ Bottle Fillers) 8 EA. $1,850.00 $14,800.00 Mop Sinks 2 EA. $800.00 $1,600.00 Floor Drains 18 EA. $465.00 $8,370.00 Hose Bibbs 8 EA. $530.00 $4,240.00 Trap Primers 18 EA. $98.00 $1,764.00 Water Heaters 2 EA. $6,000.00 $12,000.00 Mixing Valves 2 EA. $1,225.00 $2,450.00 Piping Specialties 1 L.S. $4,500.00 $4,500.00 Sanitary Waste & Vent Piping 5,000 L.F. $25.00 $125,000.00 Domestic Water Piping 5,000 L.F. $50.00 $250,000.00 Natural Gas Piping 200 L.F. $30.00 $6,000.00 Piping Hook-ups 1 L.S. $2,750.00 $2,750.00 Backflow Preventer 1 EA. $1,250.00 $1,250.00 Gas Meter & Regulator 1 EA. $2,000.00 $2,000.00 Water Meter 1 EA. $2,000.00 $2,000.00 HVAC Demolition 113,800 S.F. $0.25 $28,450.00 HVAC Mobilization 1 L.S. $50,000.00 $50,000.00 Air Handling Units 8 EA. $43,000.00 $344,000.00 Water Cooled Chillers 2 EA. $275,000.00 $550,000.00
Primary CHW Pumps 2 EA. $9,000.00 $18,000.00 Secondary CHW Pumps 2 EA. $9,500.00 $19,000.00 Condenser Water Pumps 2 EA. $9,700.00 $19,400.00 HW Pumps 2 EA. $6,000.00 $12,000.00 VAV Boxes with Reheat 85 EA. $1,450.00 $123,250.00 Fans 5 EA. $3,000.00 $15,000.00 Unit Heaters 11 EA. $1,300.00 $14,300.00 Building Automation System 1 L.S. $300,000.00 $300,000.00 Variable Frequency Drives 8 EA. $4,750.00 $38,000.00 Expansion Tank, Air Separator, Piping Specialties 2 EA. $103,000.00 $206,000.00 Chemical Treatment Systems 2 EA. $18,500.00 $37,000.00 Black Steel CHW/CW/HW Piping 2,000 L.F. $75.00 $150,000.00 Copper CHW/HW Piping 3,000 L.F. $50.00 $150,000.00 Medium Pressure Ductwork 50,000 LBS $7.00 $350,000.00 Low Pressure Ductwork 115,000 LBS $4.00 $460,000.00 Air Distribution Devices 800 EA. $175.00 $140,000.00 Ductwork Insulation 1 L.S. $108,000.00 $108,000.00
TAB 1 L.S. $60,000.00 $60,000.00
Hangers & Supports 1 L.S. $50,000.00 $50,000.00 Ductwork Accessories 1 L.S. $75,000.00 $75,000.00 Modifications to Existing Wet Pipe Sprinkler System 113,800 S.F. $3.50 $398,300.00 Clean Agent Fire Suppression System 2 EA. $90,000.00 $180,000.00 Total -15 $4,489,294.00
DIVISION 16 - ELECTRICAL
Electrical Panel Replacement/Upgrades 16 EA. $5,136.00 $82,176.00 Electrical Dry-type Transformers 8 EA. $3,168.00 $25,344.00 Electrical Main Service Panel Upgrades 1 EA. $33,840.00 $33,840.00 MCC or Elec Panel for new Mech/Chiller 1 EA. $10,536.00 $10,536.00 Electrical Connections - Pumps & Equipment 4 EA. $1,968.00 $7,872.00 Electrical Connections - VAV's 30 EA. $984.00 $29,520.00 Electrical Connections - Elevator 1 EA. $1,584.00 $1,584.00 Feeder Wiring & Conduir 1 LOT $67,680.00 $67,680.00 Branch Circuit Wiring & Conduit 1 LOT $79,680.00 $79,680.00 Wiremold in Classrooms 24 EA. $3,936.00 $94,464.00 Data/Comm wiring for Classrooms 200,000 L.F. $0.90 $180,000.00 Network Racks 8 EA. $9,840.00 $78,720.00 Total -16 $691,416.00
SUBTOTAL DIVISIONS 1 THRU 16 $7,354,855.00
Contingencies (Per DD1391) @ 5.00% $367,742.75
SUBTOTAL $7,722,597.75
Supervision, Inspection & Overhead (per UFC 3-701-01) @ 5.70% $419,226.74
TOTAL ESTIMATED CONSTRUCTION COST BASE BID $8,141,824.49
OTHER PROJECT EXPENSES
A/E Fees (per UFC 3-701-01) @ 6.00% $488,509.47
TOTAL ESTIMATED PROJECT COST BASE BID* $8,630,333.95
* Note: This Planning Charette Estimate represents the Architect's best judgment of pricing based on current construction industry pricing and historical number data. Adjustment for cost escalation over time should be considered based on the timing of this project moving forward. The Architect does not have control over the cost of labor, materials, or equipment, over the Contractor's methods of determining bid prices, or over competitive bidding, market, or negotiating conditions. Architect cannot and does not warrant or represent that bids or negotiated prices to be received will not vary from any opinion of probable construction cost prepared herein.
APPENDIX B:
Flood Map of Keesler Air Force Base (Stennis Hall is located via pin, shown outside any Flood Zone)
APPENDIX C:
Existing Conditions, Demolition and Renovation Floor Plans and Existing Elevations
162 SF
146A
ELECTRICAL
713 SF
MECHANICAL
735 SF
OFFICE (4)
747 SF
CLASSROOM
747 SF
UNDERGRADUATE CYBER
TRAINING
353 SF
STORAGE/BREAK AREA
190 SF
105B
SAFETY SECURITY
OFFICE
153 SF
105A
SAFETY SECURITY OFFICE
319 SF
105C
SAFETY SECURITY
OFFICE
318 SF
NAVY OFFICE
90 SF
104A
STOR.
172 SF
101A
ELECTRICAL
715 SF
MECHANICAL
1,409 SF
102/103
AUDITORIUM
204 SF
VACANT
243 SF
81 TSS (1)
71 SF
STOR.
75 SF
STOR. 247 SF
UCC
161 SF
140A
RESTROOM
223 SF
139A
UCC
129 SF
141A
UCC
130 SF
81 TSS OFFICE (2)
256 SF
140B
RESTROOM
266 SF
CYBER WARFARE OPERATIONS
OFFICE
306 SF
CYBER WAREFARE OPERATIONS IS
OFFICE
433 SF
BREAK/SNACK ROOM
1,303 SF
DATA CENTER
644 SF
INFRASTRUCTURE CLASSROOM
644 SF
INFRASTRUCTURE CLASSROOM
666 SF
STUDENTS NOT IN TRAINING
CLASSROOM
1,350 SF
STUDENTS NOT IN TRAINING
CLASSROOM
665 SF
INFRASTRUCTURE CLASSROOM
236 SF
CCS OFFICE
450 SF
CC OFFICE
277 SF
DO OFFICE
196 SF
153A
STORAGE
527 SF
81 TSS (4)
350 SF
154B
STORAGE
350 SF
LAB
1,240 SF
INSTRUCTOR
649 SF
A54A
STORAGE
243 SF
INSTRUCTOR OFFICE (2)
182 SF
A54C
OFFICE 66 SF
STOR.
720 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
677 SF
UNDERGRADUATE CYBER
TRAINING CAPSTONE CLASSROOM
597 SF
UNDERGRADUATE CYBER
TRAINING CAPSTONE CLASSROOM
752 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
255 SF
155B
RESTROOM
394 SF
SUB OFFICE
332 SF
CSS OFFICE
157 SF
155A
RESTROOM
578 SF
109A
SYSTEMS ADMINISTRATION OFFICE
558 SF
CONFERENCE
755 SF
109B
SERVERS
789 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
636 SF
SERVERS
1,278 SF
111A
INSTRUCTOR STAFF
881 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
1,968 SF
CYBER COURSE TRAINING
NETWORK (4)
67 SF
STOR.
246 SF
CCTN OFFICE (3)
226 SF
CCTN OFFICE (4)
149 SF
CCTN STORAGE
874 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
838 SF
UNDERGRADUATE CYBER
TRAINING
1,375 SF
111B
INSTRUCTOR STAFF
213 SF
BREAK/SNACK ROOM
249 SF
CYBER WARFARE OPERATIONS
CYBER DEV. COURSE
407 SF
CONF.
180 SF
LIBRARY
71 SF
MECH
227 SF
STORAGE
414 SF
MECHANICAL
526 SF
163A
ELECTRICAL
82 SF
163B
STORAGE
1,552 SF
MECHANICAL
646 SF
CYBER WAREFARE OPERATIONS
CLASSROOM
170 SF
120A
ELECTRICAL696 SF
MECHANICAL
642 SF
CLASSROOM
635 SF
CYBER WAREFARE OPERATIONS
CLASSROOM649 SF
CYBER WAREFARE OPERATIONS
CLASSROOM
151 SF
ENTRY
SECURE AREA
SECURE AREA PERIMETER HARDENED PARTITION
116 SF
COMM
40 SF
COMM
3/32" = 1'-0"A101
1 FIRST FLOOR EXISTING CONDITION PLAN
NORTH
C H
EC
KE
D B
Y
D R
AW
N
B Y
R
EV
IS
ED
D
AT
E
JO
B
N U
M
BE
R
SHEET
PROGRESS
DRAWING:
NOT FOR
CONSTRUCTION
C hu rc h
St re et O ce an
S pr in gs
, M S
Ph on e:
8)
-1
Em ai l:
c on ta ct al lre ds to la rs ki
.c om
A101
-5
6/
/2
8/
/2
M V, J
ES
JE
S
FI
R
S T
FL
O
O R
E X
IS
TI
N G
C O
N D
IT
IO
N P
LA
N
RE
PA
IR
S
TE
NN
IS
H
AL
L
B1
-M
AH
G
K
EE
SL
ER
A
IR
F
O R
CE
B
A
SE
B
IL
O
XI
, M
IS
SI
SS
IP
P
I
100%
SECURE AREA
SECURE AREA PERIMETER HARDENED PARTITION
162 SF
146A
ELECTRICAL
713 SF
MECHANICAL
735 SF
OFFICE (4)
747 SF
CLASSROOM
747 SF
UNDERGRADUATE CYBER
TRAINING
353 SF
STORAGE/BREAK AREA
190 SF
105B
SAFETTY SECURITY
OFFICE
153 SF
105A
SAFETY SECURITY OFFICE
319 SF
105C
SAFETY SECURITY
OFFICE
318 SF
NAVY OFFICE
90 SF
104A
STOR.
172 SF
101A
ELECTRICAL
715 SF
MECHANICAL
1,409 SF
102/103
AUDITORIUM
204 SF
VACANT
243 SF
81 TSS (1)
71 SF
STOR.
75 SF
STOR. 247 SF
UCC
5,796 SF
140A
RESTROOM
223 SF
139A
UCC
129 SF
141A
UCC
130 SF
81 TSS OFFICE (2)
5,796 SF
140A
RESTROOM
266 SF
CYBER WARFARE OPERATIONS
OFFICE
306 SF
CYBER WAREFARE OPERATIONS IS
OFFICE
433 SF
BREAK/SNACK ROOM
1,303 SF
DATA CENTER
644 SF
INFRASTRUCTURE CLASSROOM
644 SF
INFRASTRUCTURE CLASSROOM
666 SF
STUDENTS NOT IN TRAINING
CLASSROOM
1,350 SF
STUDENTS NOT IN TRAINING
CLASSROOM
665 SF
INFRASTRUCTURE CLASSROOM
236 SF
CCS OFFICE
450 SF
CC OFFICE
277 SF
DO OFFICE
196 SF
153A
STORAGE
527 SF
81 TSS (4)
350 SF
154B
STORAGE
350 SF
LAB
1,240 SF
INSTRUCTOR
649 SF
A54A
STORAGE
243 SF
INSTRUCTOR OFFICE (2)
182 SF
A54C
OFFICE 66 SF
STOR.
720 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
677 SF
UNDERGRADUATE CYBER
TRAINING CAPSTONE CLASSROOM
597 SF
UNDERGRADUATE CYBER
TRAINING CAPSTONE CLASSROOM
752 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
5,796 SF
140A
RESTROOM
394 SF
SUB OFFICE
332 SF
CSS OFFICE
5,796 SF
140A
RESTROOM
578 SF
109A
SYSTEMS ADMINISTRATION OFFICE
558 SF
CONFERENCE
755 SF
109B
SERVERS
789 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
636 SF
SERVERS
1,278 SF
111A
INSTRUCTOR STAFF
881 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
1,968 SF
CYBER COURSE TRAINING
NETWORK (4)
67 SF
STOR.
246 SF
CCTN OFFICE (3)
226 SF
CCTN OFFICE (4)
149 SF
CCTN STORAGE
874 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
838 SF
UNDERGRADUATE CYBER
TRAINING
1,375 SF
111B
INSTRUCTOR STAFF
213 SF
BREAK/SNACK ROOM
249 SF
CYBER WARFARE OPERATIONS
CYBER DEV. COURSE
407 SF
CONF.
180 SF
LIBRARY
71 SF
MECH
227 SF
STORAGE
414 SF
MECHANICAL
526 SF
163A
ELECTRICAL
82 SF
163B
STORAGE
1,552 SF
MECHANICAL
646 SF
CYBER WAREFARE OPERATIONS
CLASSROOM
170 SF
120A
ELECTRICAL696 SF
MECHANICAL
642 SF
CLASSROOM
635 SF
CYBER WAREFARE OPERATIONS
CLASSROOM649 SF
CYBER WAREFARE OPERATIONS
CLASSROOM
151 SF
ENTRY
116 SF
COMM
40 SF
COMM
DEMOLITION GENERAL NOTES:
1. DEMO ALL ELECTRICAL & MECHANICAL SYSTEMS CALLED TO BE REPLACED; PREP FOR NEW SYSTEMS
2. DEMO EXTERIOR DOORS & PREP OPENINGS TO RECEIVE NEW FRAMES AT MAIN ENTRIES
3. REMOVE ALL ACOUSTIC WALL PANELS THROUGHOUT FACILITY; PATCH & PREP WALL FOR PAINT
4. DEMO ALL RAISED COMPUTER FLOOR SYSTEMS (NOT INCLUSIVE OF RECESSED FLOORS); REROUTE ANY ELECTRICAL/DATA; PREP FOR NEW FLOOR
5. ALL EXISTING PLUMBING FIXTURES TO BE REMOVED DOWN TO SLAB, ANY EXISTING LINES TO REMAIN SHALL BE SCOPED AND JETTED PRIOR TO NEW INSTALLATION
6. ALL EXISTING ABANDONED ELECTRICAL AND MECHANICAL IS TO BE REMOVED
7. ALL EXISTING FLOORING AND CEILINGS ARE TO BE REMOVED
8. CLEAN AND PREP ALL WALLS FOR PAINT
9. ALL WALLS SHOWN DASHED ARE TO BE REMOVED
10. DEMO CONC ENTRY WALKS; PREP FOR NEW CONC WALK
C H
EC
KE
D B
Y
D R
AW
N
B Y
R
EV
IS
ED
D
AT
E
JO
B
N U
M
BE
R
SHEET
PROGRESS
DRAWING:
NOT FOR
CONSTRUCTION
C hu rc h
St re et O ce an
S pr in gs
, M S
Ph on e:
8)
-1
Em ai l:
c on ta ct al lre ds to la rs ki
.c om
A102
-5
6/
/2
8/
/2
JE
S
JE
S
FI
R
S T
FL
O
O R
D E
M O
LI
TI
O N
P
LA
N
RE
PA
IR
S
TE
NN
IS
H
AL
L
B1
-M
AH
G
K
EE
SL
ER
A
IR
F
O R
CE
B
A
SE
B
IL
O
XI
, M
IS
SI
SS
IP
P
I
100%
3/32" = 1'-0"A102
1 FIRST FLOOR DEMOLITION PLAN
NORTH
162 SF
146A
ELECTRICAL
713 SF
MECHANICAL
735 SF
OFFICE (4)
747 SF
CLASSROOM
747 SF
UNDERGRADUATE CYBER
TRAINING
353 SF
STORAGE/BREAK AREA
190 SF
105B
SAFETTY SECURITY
OFFICE
153 SF
105A
SAFETY SECURITY OFFICE
319 SF
105C
SAFETY SECURITY
OFFICE
318 SF
NAVY OFFICE
90 SF
104A
STOR.
172 SF
101A
ELECTRICAL
715 SF
MECHANICAL
1,409 SF
102/103
AUDITORIUM
204 SF
VACANT
243 SF
81 TSS (1)
71 SF
STOR.
75 SF
STOR. 247 SF
UCC 180 SF
140A
WOMEN
223 SF
139A
UCC
129 SF
141A
UCC
130 SF
81 TSS OFFICE (2) 200 SF
140B
MEN
266 SF
CYBER WARFARE OPERATIONS
OFFICE
306 SF
CYBER WAREFARE OPERATIONS IS
OFFICE
433 SF
BREAK/SNACK ROOM
1,303 SF
DATA CENTER
644 SF
INFRASTRUCTURE CLASSROOM
644 SF
INFRASTRUCTURE CLASSROOM
666 SF
STUDENTS NOT IN TRAINING
CLASSROOM
1,350 SF
STUDENTS NOT IN TRAINING
CLASSROOM
665 SF
INFRASTRUCTURE CLASSROOM
236 SF
CCS OFFICE
450 SF
CC OFFICE
277 SF
DO OFFICE
196 SF
153A
STORAGE
527 SF
81 TSS (4)
350 SF
154B
STORAGE
350 SF
LAB
1,240 SF
INSTRUCTOR
649 SF
A54A
STORAGE
243 SF
INSTRUCTOR OFFICE (2)
182 SF
A54C
OFFICE 66 SF
STOR.
720 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
677 SF
UNDERGRADUATE CYBER
TRAINING CAPSTONE CLASSROOM
597 SF
UNDERGRADUATE CYBER
TRAINING CAPSTONE CLASSROOM
752 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
200 SF
155B
MEN
394 SF
SUB OFFICE
332 SF
CSS OFFICE
182 SF
155A
WOMEN
578 SF
109A
SYSTEMS ADMINISTRATION OFFICE
558 SF
CONFERENCE
755 SF
109B
SERVERS
789 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
636 SF
SERVERS
1,278 SF
111A
INSTRUCTOR STAFF
881 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
1,968 SF
CYBER COURSE TRAINING
NETWORK (4)
67 SF
STOR.
246 SF
CCTN OFFICE (3)
226 SF
CCTN OFFICE (4)
149 SF
CCTN STORAGE
874 SF
UNDERGRADUATE CYBER
TRAINING CLASSROOM
838 SF
UNDERGRADUATE CYBER
TRAINING
1,375 SF
111B
INSTRUCTOR STAFF
213 SF
BREAK/SNACK ROOM
249 SF
CYBER WARFARE OPERATIONS
CYBER DEV. COURSE
407 SF
CONF.
180 SF
LIBRARY
71 SF
MECH
227 SF
STORAGE
414 SF
MECHANICAL
526 SF
163A
ELECTRICAL
82 SF
163B
STORAGE
1,552 SF
MECHANICAL
646 SF
CYBER WAREFARE OPERATIONS
CLASSROOM
170 SF
120A
ELECTRICAL696 SF
MECHANICAL
642 SF
CLASSROOM
635 SF
CYBER WAREFARE OPERATIONS
CLASSROOM649 SF
CYBER WAREFARE OPERATIONS
CLASSROOM
151 SF
ENTRY
116 SF
COMM
40 SF
COMM
SECURE AREA
SECURE AREA HARDENED PARTITION
(TYPE "A" STANDARD ACOUSTIC PARTITION)
UNSECURE AREA
EXISTING PARTITION
RENOVATION PLAN LEGEND
NEW SECURE PARTITION
NEW PARTITION
RENOVATION GENERAL NOTES:
1. EXTEND HARDENED PARTITION WHERE REQUIRED TO CREATE SECURE PERIMETER AROUND SECURE AREAS
2. INSTALL NEW ADA COMPLIANT IMPACT RESISTANT ENTRY SYSTEMS
3. PAINT ALL WALLS THROUGHOUT FACILITY
4. INSTALL NEW FLOORING THOUGHOUT FACILITY
5. INSTALL NEW PLUMBING FIXTURES
6. INSTALL NEW ACOUSTIC CEILING SYSTEMS THOUGHOUT FACILITY
7. CONSTRUCT NEW WALLS AS SHOWN ON DRAWINGS
8. INSTALL NEW ADA COMPLIANT ENTRY LANDINGS & WALKS AT MAIN ENTRANCES
9. INSTALL NEW ELECTRICAL & MECHANICAL SYSTEMS AS DIRECTED IN NARRATIVE
C H
EC
KE
D B
Y
D R
AW
N
B Y
R
EV
IS
ED
D
AT
E
JO
B
N U
M
BE
R
SHEET
PROGRESS
DRAWING:
NOT FOR
CONSTRUCTION
C hu rc h
St re et O ce an
S pr in gs
, M S
Ph on e:
8)
-1
Em ai l:
c on ta ct al lre ds to la rs ki
.c om
A103
-5
6/
/2
8/
/2
JE
S
JE
S
FI
R
S T
FL
O
O R
R E
N O
V A
TI
O
N P
LA
N
RE
PA
IR
S
TE
NN
IS
H
AL
L
B1
-M
AH
G
K
EE
SL
ER
A
IR
F
O R
CE
B
A
SE
B
IL
O
XI
, M
IS
SI
SS
IP
P
I
100%
3/32" = 1'-0"A103
1 FIRST FLOOR RENOVATION PLAN
NORTH
NO
RT
H
733 SF
MECHAN…