JA_Brand_Name_OR_Equal_M6261324Q0003_Redacted.pdf
PDF 482 KB Posted
- Solicitation number
- M6261324Q0003
- Issued by
-
United States Marine Corps
About this file
This document appears to be a Justification and Approval (J&A) for a brand name or equal product requirement related to a federal contract opportunity. The J&A provides details on specific boiler water treatment chemicals required for the Marine Corps Air Station (MCAS) Iwakuni in Japan, including sodium hydroxide, sulfuric acid, hydrochloric acid, potassium iodate, and various pH standard solutions. The chemicals are needed for boiler feed water treatment, pH adjustment, and water testing. The related federal contract opportunity is for Boiler Water Chemical Delivery with Incidental Services, Solicitation Number M6261324Q0003, issued by the United States Marine Corps. The contract will provide the required chemicals and support water analysis and boiler inspections at the MCAS Iwakuni location.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| JA Brand Name Only M6740024Q0003_Redacted.pdf | ||
| M6261324Q0003_Solicitation.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CUI//SP-PROCURE//DL ONLY
J&A No. M62613-FY24-SSBN-01
V1.3, 15 March 2023
Controlled by: DON, USMC, I&L HCA Controlled by: Insert the name of the office creating the document (e.g., MCINCR RCO) CUI Category(ies): PROCURE Limited Dissemination Control: DL ONLY
POC: KAORI YAMAOKA / DSN: 253-3044
Email: kaori.yamaoka.ja@usmc.mil
Sodium Hydroxide NAOH 48% 20kg/Can [Manufacturer: Takasugi Pharmaceutical Co., Ltd.]
- Boiler feed water treatment for p.h. adjustment.
- Supporting chemical for CLEANSURF S-753IW2
- Compositions: Sodium Hydroxide 48%, Water 52%
Sulfuric Acid 35% 20kg [Manufacturer: Takasugi Pharmaceutical Co., Ltd.]
- Boiler drain water treatment for p.h. adjustment
- Compositions: Sulfuric Acid 35%, Water 65%
Hydrochloric Acid HCL 6mol/L 500ml (Reagent) Product Code: 02081 [Manufacturer: Yoneyama Yakuhin Kogyo Co., Ltd.]
- SO3 test for boiler water.
- Composition: Hydrogen Chloride 19.9%, Water: 80.1%
Potassium Iodate KIO3 1/60mol/L (N/10) 500ml (Reagent) Product Code: 900-00745 [Manufacturer: Kishida Chemical Co., Ltd.]
- SO3 test for boiler water.
- Composition: KIO3 >0.36%
PH Standard Solution PH4.00 (20ºC) 500ml (Reagent) Product Code: 01799 [Manufacturer: Yoneyama Yakuhin Kogyo Co., Ltd.]
- Adjusting of ph sensor at ph neutralization tank. Boiler drain water for p.h. adjustment
- Composition: Potassium hydrogen phthalate 1%, Water: 99%
PH Standard Solution PH6.88 (20ºC) 500ml (Reagent) Product Code: 01804 [Manufacturer: Yoneyama Yakuhin Kogyo Co., Ltd.]
- Adjusting of ph sensor at ph neutralization tank. Boiler drain water for p.h. adjustment
- Composition: Potassium dihydrogenphosphate 0.34%, Disodium hydrogenphosphate 0.36 Water
99.3%
PH Standard Solution PH9.22 (20ºC) 500ml (Reagent) Product Code: 01809
[Manufacturer: Yoneyama Yakuhin Kogyo Co., Ltd.]
- Adjusting of ph sensor at ph neutralization tank. Boiler drain water for p.h. adjustment
- Composition: Sodium Tetraborate solution 100%
Potassium Chloride Solution KCL 3.3mol/L 500ml (Reagent) Product Code: 02187
[Manufacturer: Yoneyama Yakuhin Kogyo Co., Ltd.]
- Ph test for ph neutralization tank for Boiler drain water.
- Composition: Potassium Chloride Solution 100% the document (e.g., MCINCR RCO) CUI Category(ies): PROCURE Limited Dissemination Control: DL ONLY
Potassium Chloride Solution KCL 3mol/L 500ml (Reagent) Product Code: 02199 [Manufacturer: Yoneyama Yakuhin Kogyo Co., Ltd.]
- Ph test for ph neutralization tank for Boiler drain water.
- Composition: Potassium Chloride Solution 100%
Potassium Sulfate Solution K2S04 0.35mol/L 100ml (Reagent) Product Code: 32897-23
[Manufacturer: Kanto Chemical Co., Inc.]
- Cl test for boiler water
- Composition: Water solution contains 5.7% potassium sulfate
Black-T Indicator 500ml (Regent) Product Code: 910-00445
[Manufacturer: Kishida Chemical Co., Inc.]
- Water test for boiler softener tank.
- Triethanolamine 92-96%, Ethanol 3-8%, Eriochrome black T <1%
Reagent for Chloride Ion Meter Chloride Standard Solution 10ppm, 500 ml Product Code: C00062602 [Manufacturer: Central Kagaku Corp.]
- Calibration of chloride ion meter for boiler water test.
- Composition: Water solution contains 0.0016% sodium chloride (10 mg/L as chlorine)
Reagent for Chloride Ion Meter Chloride Standard Solution 1000ppm, 500 ml Product Code: C00062603 [Manufacturer: Central Kagaku Corp.]
- Calibration of chloride ion meter for boiler water test.
- Composition: Water solution contains 0.16% sodium chloride (1000mg/L as chloride)
Boiler Water Treatment Services bi-weekly Contractor shall provide all qualified personnel, supervision, supplies, materials, tools, equipment, and transportation to perform bi-weekly service visits for laboratory analysis aboard Marine Corps Air Station (MCAS) Iwakuni, in accordance with the Statement of Work (SOW) and Water Testing Location Listing in Attachment II.
Boiler Water Treatment Service annual Contractor shall provide all qualified personnel, supervision, supplies, materials, tools, equipment, and transportation to conduct boiler inspections on an annual basis aboard Marine Corps Air Station (MCAS) Iwakuni, in accordance with the Statement of Work (SOW) and Water Testing Location Listing in Attachment II.
CUI//SP-PROCURE//DL ONLY
V1.3, 15 March 2023
Controlled by: DON, USMC, I&L HCA Controlled by: Insert the name of the office creating the document (e.g., MCINCR RCO) CUI Category(ies): PROCURE Limited Dissemination Control: DL ONLY
POC: KAORI YAMAOKA / DSN: 253-3044
Email: kaori.yamaoka.ja@usmc.mil
6. Description of Efforts Made to Solicit Offers from as Many Offerors as Practicable.
This effort will be synopsized in AsiaNECO/SAM.gov in accordance with the requirements for FAR 5.2. The Contracting Office shall evaluate all responses received to determine if any other product specifications can meet the requirement. Market research in accordance with FAR Part 10 has been conducted and there are several vendors that can provide the required supplies/services.
7. Determination of Fair and Reasonable Cost. The Contracting Officer has determined that the anticipated cost to the Government of the supplies/services covered by this J&A will be fair and reasonable.
The Contracting Officer will determine that the price for this acquisition is fair and reasonable in accordance with FAR 13.106-2 and 13.106-3, and, to the extent deemed necessary by the Contracting Officer, using price analysis technique in FAR 15.404-1 (a) and (b).
8. Actions to Remove Barriers to Future Competition.
For the reasons set forth in Paragraph 5, the activity has no plans at this time to eliminate the use of the provided product listing from future solicitations for the types of supplies covered by this document; however, this will be reassessed during follow-on acquisition planning.
the document (e.g., MCINCR RCO) CUI Category(ies): PROCURE Limited Dissemination Control: DL ONLY
POC: KAORI YAMAOKA / DSN: 253-3044
CERTIFICATIONS AND APPROVAL
TECHNICAL/REQUIREMENTS CERTIFICATION
I certify that the facts and representations under my cognizance which are included in this Justification and its supporting acquisition planning documents, except as noted herein are complete and accurate to the best of my knowledge and belief.
Date
Requirements Cognizance:
LEGAL SUFFICIENCY REVIEW
I have determined that this Justification is legally sufficient. (N/A – MAPP, 1.602-1-100 Legal Review.)
Signature Name (Printed) Phone No. Date
CONTRACTING OFFICER CERTIFICATION
I certify that this Justification is accurate and complete to the best of my knowledge and belief.
August 5, 2024
August 5, 2024
August 6, 2024 the document (e.g., MCINCR RCO) CUI Category(ies): PROCURE Limited Dissemination Control: DL ONLY
Distribution List for DL ONLY Limited Dissemination Control
MCFCS Personnel
LB Personnel
Procurement Team Personnel (to include but not limited to: Legal, Customers/Requirements Owners, Source Selection Personnel, Small Business Representatives)
Any other individual designated by the KO
File details come from the government source that posted it. Updated .