This document contains mechanical engineering drawings and specifications for HVAC system replacements at Building 80 for the 156th Wing at Luis Muñoz Marín International Airport in Carolina, Puerto Rico. The drawings include details for ductwork, diffusers, registers, exhaust fans, air handling units, fan coil units, and related HVAC components. Specifications cover insulation, equipment performance criteria, controls, testing and balancing procedures. The associated federal contract opportunity is solicitation number W50S9323B0002 for the HVAC replacement project at the specified National Guard facility.

View the file

Other files

File Type Posted
Solicitation - W50S9323B0002-0002.pdf PDF
Questions Bldg.80 HVAC Replacement as of 9-13-23 Final.pdf PDF
Solicitation - W50S9323B0002-0001.pdf PDF
M-4.pdf PDF
M-8.pdf PDF
Questions Bldg.80 HVAC Replacement-W50S9323B0002.pdf PDF
ATTENDANCE ROSTER Site Visit-Bldg.80 HVAC Replacement.pdf PDF
2. QASP TUMR232120.pdf PDF
M-9.pdf PDF
MECH BLDG80.pdf PDF
TUMR 232120 Repair Bldg 80 HVAC SOW.pdf PDF
M-7.pdf PDF
HVAC System Schematics-Diagrams.pdf PDF
M-5.pdf PDF
Solicitation - W50S9323B0002.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

IN. THICK COAT OF NOKORODE SEAL KOTE, FIRE RETARDANT VAPOR

AutoCAD SHX Text

OVERLAP INSULATION APPROXIMATELY 4 INCHES ON CENTER, (FOR

AutoCAD SHX Text

FOIL FACED KRAFT, AS MANUFACTURED BY OWENS-CORNING FIBERGLASS

AutoCAD SHX Text %%uSHEET METAL AIR CASING AND PLENUMS

AutoCAD SHX Text

WITH 2 INCH NOMINAL THICKNESS, 1 1/2 LB. DENSITY, FIBERGLASS

AutoCAD SHX Text

ALL DUCT WORK SHALL BE FABRICATED WITH PRIME QUALITY ZINC

AutoCAD SHX Text

COATED SHEET IN STRICT ACCORDANCE WITH THE LOW PRESSURE DUCT

AutoCAD SHX Text

CONSTRUCTION STANDARDS OF THE SHEET METAL AND AIR CONDITIONING

AutoCAD SHX Text

CONTRACTOR NATIONAL ASSOCIATION (SMACNA, INC.) LASTEST EDITION.

AutoCAD SHX Text %%uINDOOR CONCEALED AND EXPOSED AIR DUCTS

AutoCAD SHX Text

FLEXIBLE DUCT INSULATION FACED WITH FLAME RESISTANT REINFORCED

AutoCAD SHX Text

DUCTS OVER 35 INCHES WIDTH, ADDITIONALLY SECURE INSULATION ON

AutoCAD SHX Text

BOTTOM WITH SUFFICIENT MECHANICAL FASTENERS TO PREVENT SAG).

AutoCAD SHX Text

STAPLED. SEAL ALL JOINTS, BREAKS AND PENETRATIONS WITH A 1/8

AutoCAD SHX Text

BARRIER MASTIC, COMPLETELY EMBEDDING GLASS FABRIC.

AutoCAD SHX Text

FIBERGLASS BOARD, 6 PCF MINIMUM DENSITY WITH FOIL-SCRIM-KRAFT

AutoCAD SHX Text

OR 0.006" EMBOSSED ALUMINUM VAPOR SEAL SECURED WITH WELDED

AutoCAD SHX Text

PINS OR CLIPS SET IN ADHESIVE 18" ON CENTER EACH WAY WITH 2

AutoCAD SHX Text

ROWS/PANEL MINIMUM. COVER JOINTS AND CLIPS WITH TAPE TO

AutoCAD SHX Text

TYPE NET EMBEDDED BETWEEN TWO 1/16" COATS OF VINYL-ACRILYC

AutoCAD SHX Text

OR BREATHING MASTIC. USE WEATHERIZED WHITE PROTECTIVE PAINT

AutoCAD SHX Text

AND B. FOSTER BF-3500 MASKING BOND AND NAILS. PROVIDE

AutoCAD SHX Text

WATER LEAKAGE, AND SHALL INSULATE, AS REQUIRED, ANY DUCTWORK

AutoCAD SHX Text

EXPOSED IN THE CONDITIONED SPACE IN ORDER TO PREVENT

AutoCAD SHX Text

ALL AIR CASING AND PLENUM SHALL BE CONSTRUCTED OF NO. 16 GAUGE

AutoCAD SHX Text

GALVANIZED IRON BRACED AND STIFFENED ON OUTSIDE BY MEANS OF

AutoCAD SHX Text

2" X 2" X 1/4" GALVANIZED STEEL ANGLES, OR WITH 16 GAUGE STANDING

AutoCAD SHX Text

SEAM PANELS NOT TO EXCEED 26" IN WIDTH. STANDING SEAMS ARE TO

AutoCAD SHX Text

HAVE ADDITIONAL RIGHT ANGLE BEND AND SHALL BE CAPPED WITH NO.18

AutoCAD SHX Text

GAUGE GALVANIZED "U" CAP OVER ENTIRE LENGTH OF SEAM. ALL JOINTS

AutoCAD SHX Text

SHALL BE CAULKED TO MAKE THEM AIR TIGHT. THE BOTTOM OF ALL AIR

AutoCAD SHX Text

CHAMBERS AT THE FLOOR SHALL BE GASKETED TO PREVENT AIR LEAKAGE.

AutoCAD SHX Text

PENETRATIONS THRU WALLS AND ROOF TO PREVENT MOISTURE OR

AutoCAD SHX Text

1- INSULATE ALL INDOOR CONCEALED SUPPLY AND RETURN AIR DUCT

AutoCAD SHX Text

2- FASTEN 4 IN. WIDE GLASS FABRIC TO ALL JOINTS WITH FLARE TYPE

AutoCAD SHX Text

3- WEATHER EXPOSED DUCTWORK SHALL BE INSULATED WITH A 2" RIGID

AutoCAD SHX Text

4- WEATHERPROOF OUTDOOR DUCTS WITH A LAYER OF GLASS FABRIC-FAF

AutoCAD SHX Text

5- CONTRACTORS SHALL INSTALL AN ADEQUATE FLASHING AT ALL DUCTS

AutoCAD SHX Text

THOSE OF THE CODES AND REGULATIONS, THE DRAWINGS AND SPECIFICATIONS

AutoCAD SHX Text

HEATING, REFRIGERATING AND AIR CONDITIONING ENGINEERS, AIR CONDITIONING

AutoCAD SHX Text

4. THE CONTRACTOR SHALL, TAKE EVERY PRECAUTION IN ORDER TO

AutoCAD SHX Text

MANUFACTURER FOR PROPER OPERATION.

AutoCAD SHX Text

8. CODES AND REGULATIONS REFERED TO ARE THE MINIMUM STANDARDS.

AutoCAD SHX Text

INDICATED NOR SPECIFIED BUT REQUIRED AND/OR RECOMMENDED BY THE

AutoCAD SHX Text

9. ALL EQUIPMENT SHALL BE INSTALLED AND CONNECTED AS SPECIFIED

AutoCAD SHX Text

SEALS, VALVES, ELECTRICAL CONNECTIONS, AND SIMILAR ITEMS, NOT

AutoCAD SHX Text

WHERE THE REQUIREMENTS OF THE SPECIFICATIONS OR DRAWINGS EXCEED

AutoCAD SHX Text

AND RECOMMENDATIONS. FURNISH AND INSTALL AUXILIARY PIPING, WATER

AutoCAD SHX Text

AND INDICATED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS

AutoCAD SHX Text

SHALL GOVERN.

AutoCAD SHX Text

& REFRIGERATION INSTITUTE AND NFPA 90A/90B LATEST EDITION.

AutoCAD SHX Text

FANS, DUCTWORK AND PIPING INSULATION, PLENUM LINING AND VIBRATION

AutoCAD SHX Text

EQUIPMENT MANUFACTURER, FLEXIBLE DUCTWORK LOUVERS AND SCREENS

AutoCAD SHX Text

INCLUDING CONTROL DIAGRAMS, LAYOUTS DESCRIPTION

AutoCAD SHX Text

FROM THE EQUIPMENT, PIPING SYSTEM TO THE CONDITIONED SPACE.

AutoCAD SHX Text

ISOLATORS, AND OTHER REQUIRED EQUIPMENT.

AutoCAD SHX Text

THE PUERTO RICO ENERGY CONSERVATION CODE, AMERICAN SOCIETY OF

AutoCAD SHX Text

STRICT ACCORDANCE WITH THE STANDARDS AND RECOMMENDATIONS OF

AutoCAD SHX Text

ACCESORIES AND PIPING DIAGRAMS AND LAYOUTS APPROVED BY

AutoCAD SHX Text

OF OPERATION AND CUTS OF INSTRUMENTS REFRIGERANT VALVES,

AutoCAD SHX Text

6. SUBMIT SHOP DRAWING FOR AIR HANDLING DUCT SYSTEM CONTROLS

AutoCAD SHX Text

MUST BE PERFECTLY SEALED AT ALL POINTS WHERE THEY PERFORATE

AutoCAD SHX Text

SEALED. ANY PIPE OR DUCT ENTERING OR PASSING THROUGH THIS AREA

AutoCAD SHX Text

MUST BE EXTENDED ALL THE WAY UP TO THE CEILING AND PERFECTLY

AutoCAD SHX Text

THE PERIMETRAL WALL AND PARTITIONS, WHICH DEFINE THE AREA,

AutoCAD SHX Text

5. IN ALL INDICATED AREAS OPERATING AS INDEPENDENT AIR PLENUMS

AutoCAD SHX Text

MINIMIZE OR ELIMINATE THE TRANSMISSION OF NOISE OR VIBRATION

AutoCAD SHX Text

7. THE ENTIRE AIR CONDITIONING INSTALLATION SHALL BE PERFORMED IN

AutoCAD SHX Text

THE LIMITING PARTITION.

AutoCAD SHX Text

RECOMMENDED BY THE SHEET METAL AND AIR CONDITIONING

AutoCAD SHX Text

WITH THE STANDARDS FOR LOW PRESSURE DUCT CONSTRUCTION

AutoCAD SHX Text

CONTRACTORS NATIONAL ASSOCIATION (SMACNA).

AutoCAD SHX Text

3. ALL DUCTWORK SHALL BE PERFORMED IN STRICT ACCORDANCE

AutoCAD SHX Text

PROPER OPERATION OF THE EQUIPMENT IN ACCORDANCE WITH,

AutoCAD SHX Text

EQUIPMENT IN STRICT ACCORDANCE WITH THE RULES OF THE

AutoCAD SHX Text

AND NECESSARY FOR THE PROPER OPERATION OF THE MECHANICAL

AutoCAD SHX Text

CONNECTION (POWER) NOT INDICATED IN THE ELECTRICAL DRAWINGS

AutoCAD SHX Text

2. THE MECHANICAL CONTRACTOR SHALL PERFORM ALL WIRING AND

AutoCAD SHX Text

MECHANICAL EQUIPMENT'S MANUFACTURES RECOMMENDATIONS AND

AutoCAD SHX Text

INDICATED IN THE ELECTRICAL DRAWINGS AND NECESSARY FOR THE

AutoCAD SHX Text

ELECTRICAL CONTROLS, SAFETY SWITCHES AND ACCESSORIES NOT

AutoCAD SHX Text

1. THE MECHANICAL CONTRACTOR SHALL SUPPLY AND INSTALL ALL

AutoCAD SHX Text

NATIONAL ELECTRIC CODE.

AutoCAD SHX Text

THE NATIONAL ELECTRIC CODE.

AutoCAD SHX Text %%uGENERAL NOTES:

AutoCAD SHX Text

OF SAID STRUCTURE. THIS SHALL BE DONE AS DESCRIBED IN UL CLAS

AutoCAD SHX Text

SIFIED THROUGH PENETRATION FIRESTOP SYSTEMS. USE FIRE BARRIER

AutoCAD SHX Text

19. SUBMISSION OF A BID WILL BE CONSTRUED AS EVIDENCE THAT SUCH

AutoCAD SHX Text

COULD HAVE BEEN FORESEEN HAD SUCH EXAMINATION BEEN MADE, WILL NOT

AutoCAD SHX Text

OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED, WHICH

AutoCAD SHX Text

EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT

AutoCAD SHX Text

TIONS AND DIFFICULTIES THAT WILL AFFECT THE EXECUTION OF THE

AutoCAD SHX Text

THIS WORK SO AS TO FAMILIARIZE THEMSELVES WITH EXISTING CONDI-

AutoCAD SHX Text

AND CAREFULLY EXAMINE THOSE PORTIONS OF THE SITE AFFECTED BY

AutoCAD SHX Text

18. CONTRACTOR, BEFORE SUBMITTING BIDS, SHALL VISIT THE SITE

AutoCAD SHX Text

LARGER, OVERSIZED PENETRATIONS, USE A COMBINATION OF INTUMESCENT

AutoCAD SHX Text

PUTTY AND A SUITABLE FILLER SUCH AS THERMAFIBER BY USG INTERIORS,

AutoCAD SHX Text

17. MATERIALS INSIDE A RETURN AIR PLENUMS SHALL COMPLY WITH NFPA

AutoCAD SHX Text

OR FIREDAM INTUMESCENT PUTTY BY 3M, OR EQUAL AS APPROVED. FOR

AutoCAD SHX Text

PERFECTLY SEALED SO AS TO MAINTAIN INTEGRITY AND FIRE RATING

AutoCAD SHX Text

16. ALL PENETRATIONS THROUGH FIRE RATED STRUCTURES SHALL BE

AutoCAD SHX Text

15. THE CONTRACTOR SHALL VERIFY AVAILABLE ELECTRICAL POWER

AutoCAD SHX Text

(BC-L302) ON THE SUPPLY AIR DUCTWORK, INTERLOCKED TO THE

AutoCAD SHX Text

14. OPPOSED BLADE DAMPER SHALL BE RUSKIN CD-50 OF THE SIZE

AutoCAD SHX Text

13. THE CONTRACTOR SHALL INSTALL A IONIZATION SMOKE DETECTOR

AutoCAD SHX Text

BE RECOGNIZED.

AutoCAD SHX Text

WORK.

AutoCAD SHX Text

INDICATED IN THE DRAWINGS.

AutoCAD SHX Text

BLOWER MAGNETIC STARTER.

AutoCAD SHX Text

(V, PH) BEFORE PURCHASING EQUIPMENT.

AutoCAD SHX Text

OR EQUAL AS APPROVED.

AutoCAD SHX Text

90A SECTION 2-3.10.

AutoCAD SHX Text

MATCH INSULATED FINISH.

AutoCAD SHX Text

ALUMINUM JACKET, AS SPECIFIED.

AutoCAD SHX Text

CONDENSATION OR SWEATING OF THE DUCT.

AutoCAD SHX Text

THE ADDITION OF DAMPERS, CORRECT BALANCE AS RECOMMENDED BY BA-

AutoCAD SHX Text

MANUFACTURERS EQUIPMENT NOR THE EXACT SIZE AND LOCATION OF THE

AutoCAD SHX Text

SHOW THE GENERAL LAYOUT AND DO NOT SHOW ALL THE DETAILS OF

AutoCAD SHX Text

DETAILS OF THE BUILDING OR INSTALLATION IN EVERY RESPECT. THEY

AutoCAD SHX Text

12. THE DRAWINGS ARE NOT INTENDED TO SHOW COMPLETE NOR ACCURATE

AutoCAD SHX Text

IN ACCORDACE WITH AABC RECOMMENDATIONS. SUBMIT 4 COPIES OF THE

AutoCAD SHX Text

LANCING CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.

AutoCAD SHX Text

11. ALL BALANCES, TESTS, PROCEDURES, AND REPORTS SHALL BE MADE

AutoCAD SHX Text

TOR SHALL MAKE ANY CHANGES IN THE PULLEYS, BELTS AND DAMPERS OR

AutoCAD SHX Text

FOR TESTS AND ADJUSTMENTS. AS PART OF THIS CONTRACT THE CONTRAC-

AutoCAD SHX Text

MEETING SPECIFIED CONDITIONS.FURNISH ALL LABOR AND INSTRUMENTS

AutoCAD SHX Text

TO PROVIDE UNIFORM COOLING THROUGHOUT. APPARATUS SHALL PERFORM

AutoCAD SHX Text

MAKE ALL NECESSARY TESTS, ADJUSTMENTS, AND BALANCE THE SYSTEM

AutoCAD SHX Text

10. AFTER COMPLETION OF THE INSTALLATION THE CONTRACTOR SHALL

AutoCAD SHX Text

SATISFACTORILY AND TEST NECESSARY TO SHOW IT IS CAPABLE OF

AutoCAD SHX Text

PIPING, DUCTWORK AND MACHINERY.

AutoCAD SHX Text

COMPLETE BALANCE REPORT TO THE ENGINEERS.

AutoCAD SHX Text %%uAIR HANDLING DUCT SYSTEM:

AutoCAD SHX Text %%uINSULATION SPECIFICATIONS

AutoCAD SHX Text

AN OPEN DRAIN CONNECTION SHALL BE CAST IRON

AutoCAD SHX Text

WITH JOINT AND FITTINGS MINIMUM SLOPE 1/4" FT.

AutoCAD SHX Text

PROVIDE CLEAN OUTS AND SUPPORTS ALONG LINE.

AutoCAD SHX Text

WITH THE SAME INSULATION USED FOR THE REFRIGERANT SUCTION LINES.

AutoCAD SHX Text

2- INSULATE DRAIN LINES, AT POINTS WHERE CONDENSATION MAY OCCUR

AutoCAD SHX Text

1- THE AIR CONDITIONING DRAIN LINES FROM EQUIPMENT TO

AutoCAD SHX Text %%uDRAIN LINES

AutoCAD SHX Text

PERFORMANCE OF EXHAUST FANS

AutoCAD SHX Text

MODEL MFR.

AutoCAD SHX Text

OPENING

AutoCAD SHX Text

ROOF

AutoCAD SHX Text

V-PH-HZ

AutoCAD SHX Text F.P.M.

AutoCAD SHX Text

TIP SPEED

AutoCAD SHX Text H.P.

AutoCAD SHX Text R.P.M.

AutoCAD SHX Text

SP IWG.

AutoCAD SHX Text C.F.M.

AutoCAD SHX Text

QTY.

AutoCAD SHX Text

REF.

AutoCAD SHX Text

EF-1

AutoCAD SHX Text

EF-2

AutoCAD SHX Text

RHD

AutoCAD SHX Text

RHD

AutoCAD SHX Text

RHD

AutoCAD SHX Text

SERIES 5000

AutoCAD SHX Text

SERIES 5000

AutoCAD SHX Text

SERIES 5000

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

*INDICATES MAXIMUM ALLOWABLE C.F.M

AutoCAD SHX Text

PERFORMANCE OF DIFFUSERS AND REGISTER AHU-1

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NO.

AutoCAD SHX Text 14"X14"

AutoCAD SHX Text 24"X24"

AutoCAD SHX Text 24"X24"

AutoCAD SHX Text 24"X24"

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text *C.F.M.

AutoCAD SHX Text

YES

AutoCAD SHX Text

YES

AutoCAD SHX Text

YES

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text

NECK SIZE

AutoCAD SHX Text

YES

AutoCAD SHX Text

YES

AutoCAD SHX Text

YES

AutoCAD SHX Text O.B.D.

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text

4 WAY DIFFUSER

AutoCAD SHX Text

4 WAY DIFFUSER

AutoCAD SHX Text

4 WAY DIFFUSER

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

APD. IWG

AutoCAD SHX Text

MAX. COIL

AutoCAD SHX Text

PERFORMANCE OF AIR HANDLING UNITS

AutoCAD SHX Text

COIL TOTAL

AutoCAD SHX Text

LOAD MBH

AutoCAD SHX Text

1- MAGNETIC STARTER IS REQUIRED, BY ELECTRICAL CONTRACTOR.

AutoCAD SHX Text

COIL SENSIBLE

AutoCAD SHX Text

AIR

AutoCAD SHX Text

AREA

AutoCAD SHX Text

UNIT

AutoCAD SHX Text

DESIGNATION

AutoCAD SHX Text

SERVED

AutoCAD SHX Text C.F.M.

AutoCAD SHX Text

AIR

AutoCAD SHX Text

LOAD MBH

AutoCAD SHX Text C.F.M.

AutoCAD SHX Text

DEHUMIDIFIED

AutoCAD SHX Text

OUTSIDE

AutoCAD SHX Text

VELOCITY

AutoCAD SHX Text

FACE AREA

AutoCAD SHX Text

NO.ROWS

AutoCAD SHX Text

FINS/IN.

AutoCAD SHX Text

W.P.D. (FT.)

AutoCAD SHX Text

MAX.COIL

AutoCAD SHX Text D.B.

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text W.B.

AutoCAD SHX Text D.B.

AutoCAD SHX Text F

AutoCAD SHX Text W.B.

AutoCAD SHX Text F

AutoCAD SHX Text G.P.M.

AutoCAD SHX Text

LWT

AutoCAD SHX Text

EWT

AutoCAD SHX Text

MAX.

AutoCAD SHX Text

MIN.

AutoCAD SHX Text

SQ.FT.MIN.

AutoCAD SHX Text

PRESSURE

AutoCAD SHX Text

IN. H O

AutoCAD SHX Text

F.P.M. MAX.

AutoCAD SHX Text

AutoCAD SHX Text

CHILLED WATER COIL

AutoCAD SHX Text

LVG. CONDITIONS

AutoCAD SHX Text

ENT. CONDITIONS

AutoCAD SHX Text

MIN.

AutoCAD SHX Text

EXT. STATIC

AutoCAD SHX Text

FACE

AutoCAD SHX Text

VALVE

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

RPM

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text

TOTAL STATIC

AutoCAD SHX Text

CHARACTERISTICS

AutoCAD SHX Text

PRESS. IN. H O

AutoCAD SHX Text

AutoCAD SHX Text H.P.

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

PRE FILTER

AutoCAD SHX Text

% EFF

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

IPD/FDP

AutoCAD SHX Text

% EFF

AutoCAD SHX Text

FILTER

AutoCAD SHX Text

IPD/FDP

AutoCAD SHX Text

CV

AutoCAD SHX Text

MFR

AutoCAD SHX Text

FAN

AutoCAD SHX Text

FILTER SECTION

AutoCAD SHX Text

PRE COOL

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

REHEAT

AutoCAD SHX Text T

AutoCAD SHX Text

BTUH

AutoCAD SHX Text T

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

BTUH

AutoCAD SHX Text

MFR

AutoCAD SHX Text

HEAT PIPE

AutoCAD SHX Text

AHU-1

AutoCAD SHX Text 40.5

AutoCAD SHX Text 60.3

AutoCAD SHX Text

AutoCAD SHX Text 57.2

AutoCAD SHX Text 78.2

AutoCAD SHX Text 67.7

AutoCAD SHX Text 57.5

AutoCAD SHX Text 11.9

AutoCAD SHX Text 42/52

AutoCAD SHX Text 0.3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 5.5

AutoCAD SHX Text

AutoCAD SHX Text 3/4

AutoCAD SHX Text 0.44

AutoCAD SHX Text 1.3

AutoCAD SHX Text 1800/1

AutoCAD SHX Text 208/3/60

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 3.8

AutoCAD SHX Text 92B

AutoCAD SHX Text

BC

AutoCAD SHX Text

AP-60

AutoCAD SHX Text

YORK

AutoCAD SHX Text

2WAY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PLEATED

AutoCAD SHX Text 30%

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text .25

AutoCAD SHX Text .5

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1/6

AutoCAD SHX Text 1/4

AutoCAD SHX Text 115-1-60

AutoCAD SHX Text

80C 3B L. COOK

AutoCAD SHX Text 115-1-60

AutoCAD SHX Text

DB-8 L. COOK

AutoCAD SHX Text 13 1/2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

NECK SIZE

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text

PERFORMANCE OF DIFFUSERS AND REGISTER FC-1

AutoCAD SHX Text

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

SERIES 5000

AutoCAD SHX Text

AutoCAD SHX Text 24"X24"

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text

NO.

AutoCAD SHX Text

MODEL

AutoCAD SHX Text *C.F.M.

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

4 WAY SUPPLY

AutoCAD SHX Text

YES

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text O.B.D.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DRAWN BY: A.M.T.

AutoCAD SHX Text

FILE NAME: 046-M6

AutoCAD SHX Text

COMPUTER SCALE: 1/8"=1'-0"

AutoCAD SHX Text

DATE PLOTED: 10-28-99

AutoCAD SHX Text

CHECK BY: O.M.

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text

*INDICATES MAXIMUM ALLOWABLE C.F.M

AutoCAD SHX Text A

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

RHD

AutoCAD SHX Text

AutoCAD SHX Text 14"X14"

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text

YES

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text 14"X14"

AutoCAD SHX Text 14"X14"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text

AutoCAD SHX Text

PERFORMANCE - FAN COIL UNIT

AutoCAD SHX Text

59.0 / 58.8

AutoCAD SHX Text

THROWAWAY

AutoCAD SHX Text

23.7 / 16.6

AutoCAD SHX Text

79.4 / 69.5

AutoCAD SHX Text

YORK

AutoCAD SHX Text

HCP10

AutoCAD SHX Text 115/1/60

AutoCAD SHX Text

SPEED

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

V-PH-CY

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

SELECTION

AutoCAD SHX Text

FILTERS

AutoCAD SHX Text

MFR

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

QTY.

AutoCAD SHX Text

LDB / LWB

AutoCAD SHX Text

EDB/EWB

AutoCAD SHX Text

TMBH/SMBH

AutoCAD SHX Text

AMP/HP

AutoCAD SHX Text

FAN

AutoCAD SHX Text

COIL

AutoCAD SHX Text E.S.P

AutoCAD SHX Text

ROWS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HIGH

AutoCAD SHX Text

AutoCAD SHX Text 0.10

AutoCAD SHX Text

AutoCAD SHX Text

ABOVE CEILING

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

LOCATION

AutoCAD SHX Text

SERVES

AutoCAD SHX Text

SA CFM

AutoCAD SHX Text

REF.

AutoCAD SHX Text

AutoCAD SHX Text

FC-1

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text

PERFORMANCE OF REGISTER EF-2

AutoCAD SHX Text

NECK SIZE

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text B

AutoCAD SHX Text

NO.

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

RHD

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

AutoCAD SHX Text *C.F.M.

AutoCAD SHX Text 14"X14"

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

YES

AutoCAD SHX Text O.B.D.

AutoCAD SHX Text 10"X6"

AutoCAD SHX Text A

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

RHD

AutoCAD SHX Text

AutoCAD SHX Text 12"X8"

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text

YES

AutoCAD SHX Text

*INDICATES MAXIMUM ALLOWABLE C.F.M

AutoCAD SHX Text 10"X8"

AutoCAD SHX Text

NECK SIZE

AutoCAD SHX Text 12"X12"

AutoCAD SHX Text

PERFORMANCE OF REGISTER EF-1

AutoCAD SHX Text 10"X6"

AutoCAD SHX Text

*INDICATES MAXIMUM ALLOWABLE C.F.M

AutoCAD SHX Text

MANUFACTURER

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text

NO.

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

METAL AIRE

AutoCAD SHX Text

RHD

AutoCAD SHX Text

MODEL

AutoCAD SHX Text

RHD

AutoCAD SHX Text

RHD

AutoCAD SHX Text

AutoCAD SHX Text *C.F.M.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 12"X10"

AutoCAD SHX Text 12"X8"

AutoCAD SHX Text

SIZE

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text

RETURN REGISTER

AutoCAD SHX Text

YES

AutoCAD SHX Text O.B.D.

AutoCAD SHX Text

YES

AutoCAD SHX Text

YES

AutoCAD SHX Text 12"X8"

AutoCAD SHX Text

MODULATING

AutoCAD SHX Text

WATER

AutoCAD SHX Text

GPM

AutoCAD SHX Text

EWT/LWT

AutoCAD SHX Text

WPD

AutoCAD SHX Text 4.8

AutoCAD SHX Text 42/52

AutoCAD SHX Text

AutoCAD SHX Text

JOSE A. BATLLE AND ASSOCIATES

AutoCAD SHX Text engineers - planners - architects

AutoCAD SHX Text A

AutoCAD SHX Text J

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text p.o. box 78

AutoCAD SHX Text san juan, puerto rico

AutoCAD SHX Text

SCALE :

AutoCAD SHX Text

DWG. BY:

AutoCAD SHX Text

REVISED BY:

AutoCAD SHX Text

LUIS MUNOZ MARIN INTERNATIONAL AIRPORT CAROLINA, P.R.

AutoCAD SHX Text

156 TH AIRLIFT WING PRANG

AutoCAD SHX Text

NO.

AutoCAD SHX Text

DRAWING TITLE:

AutoCAD SHX Text

REVITIONS:

AutoCAD SHX Text 00919

AutoCAD SHX Text

DATE :

AutoCAD SHX Text

ANG NO.

AutoCAD SHX Text

PROJECT NO.:

AutoCAD SHX Text

OF

AutoCAD SHX Text

DWG. NO.

AutoCAD SHX Text O S V A L D O M A R C A N O

AutoCAD SHX Text

OM

AutoCAD SHX Text

OM

AutoCAD SHX Text

OM

AutoCAD SHX Text

OM

AutoCAD SHX Text

OM

AutoCAD SHX Text

OM

AutoCAD SHX Text

OM

AutoCAD SHX Text (787)

AutoCAD SHX Text

(FAX)

AutoCAD SHX Text (787)

AutoCAD SHX Text 273-0390

AutoCAD SHX Text 273-0260

AutoCAD SHX Text 781-9080

AutoCAD SHX Text omarcano@caribe.net

AutoCAD SHX Text

SUMMIT HILLS

AutoCAD SHX Text

GUAYNABO, P.R.

AutoCAD SHX Text

553 HILLSIDE ST.

AutoCAD SHX Text

CONSULTANTS:

AutoCAD SHX Text

MECHANICAL ENGINEERS

AutoCAD SHX Text

NOTES & SCHEDULE

AutoCAD SHX Text M-6

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1/8"=1'-0"

AutoCAD SHX Text 5/5/00

AutoCAD SHX Text

ADDITIONS & ALTERATIONS TO:

AutoCAD SHX Text

SQUADRON

AutoCAD SHX Text

OPERATIONS FACILITY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BLDG. NO. 80

AutoCAD SHX Text

TUMR 989061

Sheets and Views
Model

File details come from the government source that posted it. Updated .