M-001_York Reference Submittal Data.pdf

PDF 288 KB Posted

Attached to
ENVIRONMENTAL CONTROL UNIT Federal contract opportunity
Solicitation number
W25G1V21Q0005
Issued by
Department of the Army Materiel Command Army Contracting Command Aberdeen Proving Ground

View the file

Other files for this federal contract opportunity

Other files attached to ENVIRONMENTAL CONTROL UNIT, newest first.
File Type Posted
W25G1V20Q0005 AMENDMENT 2.pdf PDF
W25G1V20Q0005 AMENDMENT 1.pdf PDF
E-002_Reference Ancilllary Electric Submittal.pdf PDF
M-003_Frame Fabrications Reference Shop Drawing.pdf PDF
W25G1V21Q0005.pdf PDF
E-001_Reference Pin and sleeve HOCC.PDF PDF
M-002_Mobile ECU Concept Sketch.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBMITTAL DATA

For: Approval

Order #: Date: 02/01/2017 Project: Tobyhanna Army Depot (Troy) Project #:

Location:

Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/01/2017 anthony.shebelock Typewritten Text PROVIDE FIELD INSTALLED ACCESSORIES AS NOTED ON PAGE 4. AS SEPARATE SUBMITTAL PROVIDE SHOP DRAWING OF PROPOSED MOBILE ECU WITH FRAME AND ALL ADDITIONAL ACCESSORIES AS SPECIFIED IN THE SOW

Date 02/01/2017 Project Name Tobyhanna Army Depot (Troy) Project Number Client / Purchaser

Submittal Summary Page

Qty Tag # Model # Description 1 ZE036E10D4A1AAA1A1 3 Ton, Single Stage Cooling, York Small Sunline Single Packaged R-

410A Air Conditioner, 12.0 EER / 14.0 SEER, 10 kW Single Stage Factory Installed Electric Heat, 460-3-60

• 1.5 HP High Static Belt Drive Blower

• 1" Throwaway Filters

• Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors

• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil

• Galvanized Steel Drain Pan

• Standard Access Doors

Equipment start-up and commissioning by a factory trained technician is recommended.

Contact your supplying distributor or sales representative for additional information & guidance.

Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/01/2017

Cooling Performance Total gross capacity 37.2 MBH Sensible gross capacity 27.3 MBH Total net capacity 34.6 MBH Sensible net capacity 24.7 MBH Seasonal Efficiency (at ARI) 14.00 SEER Efficiency (at ARI) 12.00 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 61.9 °F Leaving WB temp. 58.7 °F Power input (w/o blower) 2.55 kW Sound power 81 dB(A)

Refrigerant Refrigerant type R-410A

Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 34.5 MBH Nominal electric heat 10 kW Applied electric heat 10.1 kW Installed Factory Supply air 1400 CFM Leaving DB temp. 82.8 °F Air temp. rise 22.8 °F Stages 1

Supply Air Blower Performance Supply air 1400 CFM Ext. static pressure 1.1 IWG Addl. Unit Losses (Options/Accessories) -0.06 IWG Blower speed 1112 RPM Duct location Bottom Motor rating 1.50 HP Actual required BHP 0.81 HP Power input 0.75 kW Elevation 0 ft.

Drive type BELT

Electrical Data Power supply 460-3-60 Unit min circuit ampacity 17.8 Amps Unit max over-current protection 20 Amps

Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in.

Weight with factory installed options 501 lbs.

Clearances Right 24 in. Front 24 in. Back 12 in.

Top 72 in. Bottom 0 in. Left 24 in.

Note: Please refer to the tech guide for listed maximum static pressures

3 Ton

• York Units are Manufactured at an ISO 9001 Registered Facility and Each

Rooftop is Completely Computer-Run Tested Prior to Shipment.

Unit Features

• Single Stage Cooling

• Single Stage Cooling

• 10 kW Single Stage Factory Installed Electric Heat

• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours

Salt Spray Test (ASTM B-117 Standards)

• Full Perimeter Base Rails with Built in Rigging Capabilities

• Either Supply and/or Return can be Field Converted from Vertical to

Horizontal Configuration without Cutting Panels.

• Scroll Compressor

• 1.5 HP High Static Belt Drive Blower

• Unit Ships with 1" Throwaway Filters

• Solid Core Liquid Line Filter Driers

• Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2").

Unit accepts 1" or 2" wide filters.

• Through-the-Curb and Through-The-Base Utility Connections

• Short Circuit Current: 5kA RMS Symmetrical

• Single Point Power Connection

• Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin

Evaporator Coil

• Galvanized Steel Drain Pan

• Standard Access Doors Standard Unit Controller: Simplicity Control Board

• An Integrated Low-Ambient Control, Anti-Short Cycle Protection, Lead-Lag, Fan On and Fan off Delays, Low Voltage Protection, On-Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention.

• Safety Monitoring - Monitors the High and Low-Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips.

BAS Controller

• Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air

Temperature Sensors Warranty

• One (1) Year Limited Warranty on the Complete Unit

• Five (5) Year Warranty - Compressors and Electric Heater Elements

Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/01/2017

Small Sunline (3-6 Ton Package) N543

Single Package R-410A Air Conditioner

Page: 3

Project Name: Tobyhanna Army Depot (Troy) Unit Model #: ZE036E10D4A1AAA1A1 Quantity: 1 System: ZE036E10D4A1AAA1A1

Factory Installed Options

ZE036E10D4A1AAA1A1

Product Category: ZE

York Small Sunline Single Packaged R-410A Air Conditioner

12.0 EER / 14.0 SEER

Nominal Cooling Capacity: 036 3 Ton

Single Stage Cooling

Heat Type and Nominal Heat Capacity: E10 10 kW Single Stage Factory Installed Electric Heat Airflow Options: D 1.5 HP High Static Belt Drive Blower Voltage: 4 460-3-60

Controls: A Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors

Refrigeration: A Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil

Additional Options: 1 1" Throwaway Filters

Cabinet Options: A Galvanized Steel Drain Pan Standard Access Doors

Product Generation: 1

Field Installed Accessories

Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/01/2017

Small Sunline (3-6 Ton Package) N543

Single Package R-410A Air Conditioner

Page: 4

Project Name: Tobyhanna Army Depot (Troy) Unit Model #: ZE036E10D4A1AAA1A1 Quantity: 1 System: ZE036E10D4A1AAA1A1

SCR for control of electric heat by return temperature sensor RAWAL valve for capacity control of the cooling system Galvanized panels for interior lining of indoor airflow compartments anthony.shebelock Polygon anthony.shebelock Typewritten Text Cambridge coil guards anthony.shebelock anthony.shebelock

C on so lid at ed

D ra w in g

4.

[1

,1

8.

[2

,2

4.

[1

,6

.0

[2

,0

.0

[8

,2

6.

[1

,7

7.

[1

,0

.2

[4

,7

.5

[2

,1

.5

[4

,5

]5.

[1

,6

5.

[1

,0

.2

[3

,3

.6

[8

,3

6.

[1

,5

6.

[1

,2

.8

[8

,0

.8

[1

9, 8]

.5

[8

,7

.1

[2

7, 6] 2.

[6

4, 7]

4.

[1

,3

.5

[2

,1

3.

[7 6, 2]

.5

[2

,1

.0

[4

,6

7.

[1

,6

.5

[4

,5

.6

[8

,2

6.

[1

,1

.5

[4

,5

.6

[4

,7

3.

[9 6, 0] 4.

[1

,3

XY

.5

[6

,6

1.

[4

5, 8]

1.

K .O

[5

0, 0]

0.

K .O

[2

2, 2]

.3

[6

,7

.5

[4

,9

NO

TE

S:

1.

F

OR

O

UT

DO

OR

U

SE

O

NL

Y.

2.

W

EI

GH

TS

S

HO

WN

A

RE

OR

CO

OL

IN

G

ON

LY

U

NI

TS

3.

M

IN

CL

EA

RA

NC

ES

T O

BE

RI

GH

T

SI

DE

9, 6]

LE

FT

S

ID

E:

9, 6]

LE

SS

E

CO

NO

MI

ZE

R)

4, 4]

WI

TH

E

CO

NO

MI

FR

ON

T:

9, 6]

CO

OL

IN

G/

EL

EC

TR

IC

H

EA

T)

2, 8]

GA

S

HE

AT

RE

AR

4, 8]

LE

SS

E

CO

NO

MI

4, 4]

WI

TH

E

CO

NO

MI

ZE

R

OR

F

IX

ED

A

IR

/M

OT

OR

IZ

ED

D

AM

PE

TO

P:

,8

BO

TT

OM

0]

4.

OR

S

MA

LL

ER

S

ER

VI

CE

A

ND

O

PE

RA

TI

ON

AL

C

LE

AR

AN

CE

S

ON

TA

CT

Y

OU

R

AP

PL

IC

AT

IO

N

EN

GI

NE

ER

IN

G

DE

PA

RT

ME

NT

5.

D

OW

NF

LO

W

DU

CT

S

DE

SI

GN

ED

T O

BE

A

TT

AC

HE

D

TO

A

CC

ES

SO

RY

R

OO

F

CU

RB

O

NL

Y.

I F

UN

IT

I S

MO

UN

TE

D

SI

DE

S

UP

PL

Y, I T

I

RE

CO

MM

EN

DE

D

TH

AT

T

HE

D

UC

TS

A

RE

S

UP

PO

RT

ED

B Y

RO

SS

B

RA

CE

S, A

S

DO

NE

O

N

AC

CE

SS

OR

Y

RO

OF

C

UR

BS

6.

ID

E

DU

CT

F

LA

NG

ES

A

RE

.8

[2

2, 2]

H

IG

H.

B

OT

TO

M

DU

CT

S

DO

N

OT

H

AV

E

FL

AN

GE

S.

7.

M

IN

IM

UM

C

ON

DE

NS

AT

IO

N

TR

AP

H

EI

GH

T

SH

AL

L

BE

.5

T

IM

ES

HE

L

OW

ES

T

NE

GA

TI

VE

S

TA

TI

C.

8.

IM

EN

SI

ON

S

IN

AR

E

IN

M

IL

LI

ME

TE

RS

O R

KI

LO

GR

AM

S.

9.

O

PT

IO

NA

L

CO

IL

G

UA

RD

GA

S

HE

AT

EC

ON

OM

IZ

ER

H

OO

D, IS

CO

NN

EC

T

SW

IT

CH

CO

NV

EN

IE

NC

E

OU

TL

ET

AN

O

UT

LE

T/

IN

LE

T

HO

OD

S

HO

WN

DI

RE

CT

IO

N

OF

A

IR

FL

OW

CE

NT

ER

O

F

GR

AV

IT

Y

E

XC

EP

(H

EA

T

PU

MP

UN

IT

S.

X

N X

P

TO

NN

AG

E

U N I T

OP

ER

AT

IN

G

WE

IG

HT

LB

S) (B

AS

E

UN

IT

CE

NT

ER

O

F

GR

AV

IT

Y L

OC

AT

IO

N

(B

AS

E

UN

IT

PO

IN

T

CO

RN

ER

L

OA

DS

LB

S)

BA

SE

U

NI

T)

X Y

A B

C D

[2

.5

6, 3]

.2

[4

,6

[5

0]

[5

3]

[7

3]

[2

4, 4]

.5

[4

,9

[6

3]

[4

9]

[7

0]

[9

0]

[2

.5

2, 5]

.2

2, 3]

[6

3]

[5

3]

[7

8]

[9

3]

[2

8, 2]

.2

[4

,6

[5

2]

[5

0]

[7

6]

[2

.5

[8

,1

.5

[4

,9

[6

3]

[5

5]

[8

9]

[2

9, 8]

1]

[4 8]

[7 7]

[9 4]

[2

9, 8]

1]

[5

4]

[8

7]

[1

[2

8]

[6

0]

[5

7]

[7

0]

[7

4]

[2

8]

[6 1]

[5 8]

[7 2]

[7 6]

[2

8]

[6

1]

[5

8]

[7

2]

[7

6]

[2

.3

2, 8]

.7

[4

,3

[6 2]

[5 4]

[7 5]

[8 6]

[2

.2

0, 3]

.4

7, 4]

[6 1]

[5 3]

[7 7]

[8 8]

[2

.6

0, 4]

7, 2]

[6

0]

[5

3]

[7

9]

[8

9]

[2

0, 6]

8]

[6 1]

[5 5]

[6 9]

[7 6]

[2

0, 6]

8]

[6

2]

[5

6]

[7

0]

[7

8]

[2

0, 6]

8]

[6 3]

[5 7]

[7 0]

[7 8]

XPXPXPXNXNZRZFZFZFZFZE ZE ZE ZR ZR XN

VE

NT

A

IR

O

UT

LE

T

HO

OD

CO

MB

US

TI

ON

A

IR

I

NL

ET

H

OO

D

GA

S

SU

PP

LY

E

NT

RY

1.

,4

CO

NV

EN

IE

NC

E

OU

TL

ET

CO

VE

R

(O

PT

IO

NA

L)

DI

SC

ON

NE

CT

S

WI

TC

H

CO

VE

R

(O

PT

IO

NA

L)

FR

ON

T

VI

EW

BL

OW

ER

AC

CE

SS

CT

L

BO

X

AC

CE

SS

CO

MP

AC

CE

SS

GA

S

HE

AT

AC

CE

SS

CO

IL

G

UA

RD

(O

PT

IO

NA

L)

RI

GH

T

VI

EW

PO

WE

R

WI

RI

NG

B

OT

TO

M

EN

TR

2.

,8

CO

NT

RO

L

WI

RI

NG

B

OT

TO

M

EN

TR

0.

,2

R E T U R N

S U P P L Y

GA

S

SU

PP

LY

B

OT

TO

M

EN

TR

Y

1.

,1

K.

O.

(0 .5

[1

2, 7]

N

PT

A T

GA

S

VA

LV

E

A B C

D

RI

GH

T

RE

AR

RE

AR

PA

RT

IA

L

VI

EW

(R

AI

N

HO

OD

N

OT

S

HO

WN

I N

TH

IS

V

IE

W)

SU

PP

LY

EC

ON

O

O/ A

RE

TU

RN

O/ A

0.

,1

PV

C

FP

T

CO

ND

DR

AI

N

EC

ON

OM

IZ

ER

H

OO

D

(O

PT

IO

NA

L)

LE

FT

V

IE

W

FI

LT

ER

AC

CE

SS

BL

OW

ER

AC

CE

SS

U ni ta ry

S al es T oo l v

1.

5.

9.

In fo rm at io n is s ub je ct to c ha ng e w ith ou t n ot ic e.

C he ck lo ca l c od es

P rin te d

/0

1/

Sm al l S un lin e

(3 -6

T on

P ac ka ge

) N

Si ng le

P ac ka ge

R -4

A

A ir

C on di tio ne r

P ag e:

P ro je ct

N am e:

T ob yh an na

A rm y D ep ot

(T ro

y) U ni t M od el

Z E0

E1

0D 4A

1A A

A 1A

Q ua nt ity ys te m

Z

E0

E1 0D

4A 1A

A A

1A

Date 02/01/2017 Project Name Tobyhanna Army Depot (Troy) Project Number Client / Purchaser

Guide Specification Summary Page

Product Series Models and Unit Tags Small Sunline (3-6 Ton Package) N543 ZE036E10D4A1AAA1A1

Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/01/2017

GENERAL

Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. York Sunline units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory-mounted options and field-installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only.

For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit.

All non-Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5-year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty.

DESCRIPTION

Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat are designed for outdoor mounted installation.

The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have

11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0

EER. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with

DOE and AHRI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards.

UNIT CABINET

Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2” thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be “large” size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards. Condensate connection shall be a minimum of 3/4” I.D. female and be a ridged mount connection.

INDOOR (EVAPORATOR) FAN ASSEMBLY

The indoor fan shall be a factory installed direct-drive or belt-drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation.

Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance.

OUTDOOR (CONDENSER) FAN ASSEMBLY

The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently.

Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/01/2017

Guide Specification for York Sunline

Page: 7

REFRIGERANT COMPONENTS

Compressors:

a. Shall be internally protected with internal high-pressure relief and over temperature protection.

b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting.

Coils:

a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option.

b. Evaporator coils shall be of the direct expansion, draw-thru design.

c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro-Channel aluminum tube, aluminum fins.

d. Condenser coils shall be of the direct expansion, draw-thru design.

Refrigerant Circuit and Refrigerant Safety Components shall include:

a. Independent fixed-orifice or thermally operated expansion devices.

b. Filter drier/strainer to eliminate any moisture or foreign matter.

c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge.

d. The refrigeration system shall provide at least 15°F of sub-cooling at design conditions.

Unit Controls:

a. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side.

b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor.

c. Loss-of-charge/Low-pressure switch.

d. High-pressure switch.

e. Freeze-protection thermostat, evaporator coil.

f. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection.

g. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up.

h. Unit control board shall have on-board diagnostics and fault code display.

i. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0°F.

j. Control board shall monitor each refrigerant safety switch independently.

k. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss.

ELECTRIC HEATING SECTION

An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 30 KW, offering two stages of capacity - 16 KW and above on 208/230 volt heaters and 20 KW and above on 460 and 575 volt heaters. The heating section shall have a primary limit control(s) and automatic reset to prevent the heating element system from operating at an excessive temperature. The heating section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating shall be wired for a single point power supply with branch circuit fusing (where required).

UNIT OPERATING CHARACTERISTICS

Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature.

ELECTRICAL REQUIREMENTS

All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring.

STANDARD LIMITED WARRANTIES

• Compressor 5 Years

• Heat Exchanger 10 Years

• Electric Heat Element 5 Years

• Other Parts 1 Year

ADDITIONAL FACTORY INSTALLED OPTIONS

Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/01/2017

Page: 8

• BAS Controls

• High Static Drive - Includes a belt, blower pulley, motor pulley or a motor change to enhance blower performance.

FIELD INSTALLED OPTIONS

Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/01/2017

Page: 9

File details come from the government source that posted it. Updated .