This technical specification drawing is for a Daktronics LED display system measuring 17.07' x 30.19' (13x23 modules) with a flat border design. The display features RGB LED color capability, all-aluminum construction with front and rear accessibility, and ships in two sections requiring on-site assembly. Key specifications include an active display area of 514.943 square feet, matrix size options of 520 x 920 pixels (10SMD) or 312 x 552 pixels (16MT), total weight of 5,325 pounds split between Section 100 (2,902 lbs) and Section 200 (2,423 lbs), and structural ratings supporting wind pressures up to 72 PSF with specific mount spacing requirements.
Installation requirements specify that the customer is responsible for designing and certifying the support structure, obtaining local certification for steel mounting, and providing appropriate lifting equipment with safety factors, while sections cannot be lifted in wind speeds above crane capacity or OSHA's 20 MPH limit. The display includes rear intake and exhaust ventilation systems requiring 19.333 square feet of open area for natural convection or 5,800 CFM forced ventilation if natural convection cannot be achieved. Power ratings are referenced in a separate drawing (5280640), and multiple mounting options are available including rocker with/without ledger beam mounts, offset rocker beam mounts, T-clip stringer mounts, and lug mounts, with detailed drawings provided for each mounting method.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ+Daktronic25.docx | DOCX document | |
| Biesot+Electrical+and+Signal+DWG.pdf | ||
| Biesiot+Certified+Drawing.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
"B" "A"
17' 3/4" [5200]
ACTIVE
HEIGHT
9' 2-5/16" [2801]
SECTION
SPLICE
30' 2-3/16" [9200]
ACTIVE WIDTH
30' 2-5/16" [9203]
OVERALL WIDTH
11-1/16" [281]
DISPLAY DEPTH
7' 10-1/2" [2400] 14' 5-5/16" [4403]
LIFTEYE SPACING 7' 10-1/2" [2400]
1-1/2" [38]
LIFTEYE DIAMETER
17' 13/16" [5203]
OVERALL
HEIGHT
SI
G
N
AL
E N
TR
AN
C E
7-
/1 6"
D
IS
PL
AY
LE
FT
S
ID
E
0" 0[
PO
W
ER
E
N
TR
AN
C
E 2'
-1
/8
POWER/SIGNAL
ENTRANCE
2' 8-1/2" 826[ ]
DISPLAY BOTTOM
0" 0[ ]
POWER ENTRANCE
11' 10-3/4" 3626[ ]
NOTE# DETAIL DESCRIPTION
1 LED COLOR RGB
2 CABINET CONSTRUCTION DISPLAY IS ALL ALUMINUM CONSTRUCTION
3 ACCESS DISPLAY IS FRONT AND REAR ACCESSIBLE
SPARE PARTS ARE REAR ACCESS ONLY.
4 SHIPPING DISPLAY IS SHIPPED IN 2 SECTIONS. ASSEMBLY OF
SECTIONS IS REQUIRED ON-SITE.
STRUCTURAL RATING SEE DD4145274 FOR APPLICABLE DESIGN CODE.
MOUNT SPACING TABLE:
IF MOUNT SPACINGS FALL OUTSIDE LISTED RANGE, CONTACT DAKTRONICS ENGINEERING.
ASD DESIGN WIND PRESSURE "P" P<= 72 PSF [3,447 KPa]
MOUNT SPACING "A"
C-C
MIN: 9' 1-1/8" [2772]
MAX: 16' [4877]
CANTILEVER SPACING "B"
MIN: 1' [304,8]
EDGE OF MOUNT TO END OF DISPLAY
MAX: 6' [1829] C - END OF DISPLAY
# OF MOUNT COLUMNS 3
MOUNTING DETAIL DRAWING TABLE:
REFER TO DRAWING SELECTED MOUNTING METHOD
ROCKER W/ LEDGER (BEAM MOUNT) 5214650
ROCKER W/O LEDGER (BEAM MOUNT) 5214651
OFFSET ROCKER W/ LEDGER (BEAM MOUNT) 5214654
T-CLIP (STRINGER MOUNT) 5214655
LUG (LUG MOUNT) 5214656
7 POWER RATING REFER TO DRAWING 5280640 FOR POWER RATING OF DISPLAY.
8 INSTALLATION
PROCESS
1. REFER TO INSTALLATION AND MAINTENANCE MANUAL FOR
COMPLETE INSTALLATION INSTRUCTIONS.
2. FOR DISPLAYS TWO LEVELS OR TALLER; MAX OF 2 VERTICAL
SECTIONS MAY BE SPLICED AND LIFTED TO THE STRUCTURE.
ALTERNATIVELY, INDIVIDUAL SECTIONS MAY BE LIFTED
SPLICED ON THE STRUCTURE.
3. SECTIONS SHALL NOT BE LIFTED IN WIND SPEEDS ABOVE
CRANE'S RATED CAPACITY OR OSHA'S 20MPH LIMIT.
4. LIFTEYE MINIMUM LIFT ANGLE OF 55° FROM HORIZONTAL.
9 INSTALLATION
RESPONSIBILITY
1. CUSTOMER IS RESPONSIBLE FOR DESIGNING AND
CERTIFYING THE SUPPORT STRUCTURE.
2. CUSTOMER IS RESPONSIBLE FOR OBTAINING LOCAL
CERTIFICATION FOR THE STEEL MOUNTING STRUCTURE.
3. CUSTOMER IS RESPONSIBLE FOR SUPPLYING EQUIPMENT
WITH APPROPRIATE SAFETY FACTOR TO LIFT DISPLAY.
4. DAKTRONICS AND CUSTOMER ARE RESPONSIBLE FOR
CONFIRMING THE MOUNT QUANTITIES TO MEET THE
STRUCTURAL REQUIREMENTS. DAKTRONICS IS
RESPONSIBLE FOR PROVIDING MOUNTS OF THE CORRECT
QUANTITY.
10 VENTILATION REAR INTAKE & EXHAUST
ENCLOSED STRUCTURE
VENTILATION
REQUIREMENTS
(WHERE APPLICABLE)
1. OPEN AREA REQUIREMENTS FOR NATURAL CONVECTION:
PER DISPLAY = 19.333 FT² [1.796 M²] EACH AT INTAKE AND
EXHAUST.
2. FORCED VENTILATION REQUIREMENT IF #1 CANNOT BE MET:
PER DISPLAY = 5800.000 CFM [164.140 CMM] WITH 19.333 FT²
[1.796 M²] AT THE INTAKE.
3. ACTIVE COOLING REQUIREMENTS IF #2 CANNOT BE MET:
CONTACT DAKTRONICS
4. INTAKES, EXHAUSTS, AND STRUCTURE FANS SHOULD BE
EQUALLY SPACED HORIZONTALLY ALONG THE WIDTH OF
THE DISPLAY.
DETAIL DESCRIPTION
OVERALL DISPLAY
MATRIX SIZE
PIXELS HIGH x PIXELS WIDE - PIXEL SPACING 520 x 920 - 10SMD 312 x 552 - 16MT
ACTIVE AREA 514.943 SQ. FT. [47.840 SQ. METERS]
OVERALL AREA 515.337 SQ. FT [47.876 SQ. METERS]
WEIGHT
SECTION 100 = 2902 LBS [1316 KGS]
SECTION 200 = 2423 LBS [1100 KGS]
TOTAL WEIGHT: 5325 LBS [2416 KGS]
REV: DATE: DESCRIPTION: BY:
01 1 MAY 24 PER CN-178314; UPDATED WEIGHTS FOR FINAL DESIGN SRL
21715
THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS DRAWING
ARE CONFIDENTIAL AND PROPRIETARY. DO NOT REPRODUCE BY
ANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OF
DAKTRONICS, INC. OR ITS WHOLLY OWNED SUBSIDIARIES.
COPYRIGHT 2023 DAKTRONICS, INC. (USA)
THIRD ANGLE PROJECTION
PROJECT: LARGE FORMAT SECTIONAL CHASSIS
TITLE: SHOP/SPECS; 17.07'X30.19'(13X23 MODS)FB, 2PL
DATE: 01-MAY-24 DIM UNITS: FT-IN [MILLIMETERS] SHEET REV
SCALE: 1/60 DO NOT SCALE DRAWING 1 OF 2 01
DESIGN: JCOOK JOB NO. FUNC - TYPE - SIZE 5278977DRAWN: HPSZANK P2389 E - 10 - B
FLAT BORDER
PAINTED ALL
AROUND
FRONT VIEW
SECTION 100
SECTION 200
SIDE VIEW
REAR VIEW
VENTILATION
INTAKE AREA. ALL
SECTIONS TYP.
VENTILATION
EXHAUST AREA.
ALL SECTIONS TYP.
REMOVABLE
REAR ACCESS
DOORS. ALL
SECTIONS TYP.
ONE MOUNT COLUMN. SEE
"NOTE #5 MOUNT
SPACING TABLE" FOR
SPACING AND QAUNTITIES TO
MEET DESIRED WIND
PRESSURE
MOUNT LOCATION. SEE "NOTE
#6 MOUNTING DETAIL
DRAWING TABLE"
SUBMITTAL APPROVAL
COMPANY:
SIGNED:
TITLE:
APPROVED
APPROVED AS NOTED
APPROVED AS NOTED & RESUBMIT
DATE:
File details come from the government source that posted it. Updated .