LS_No_7_Bid_Set_-_Drawings.pdf
PDF 22 MB Posted
- Attached to
- 2558ITB - Lift Station 7 Repairs and Upgrades
- Solicitation number
- 2558
- Issued by
- Volusia County, Florida
About this file
These construction drawings detail the Lift Station No. 7 Repairs and Upgrades project for the City of Daytona Beach Utilities Department, located in Volusia County, Florida. The project involves comprehensive repairs and replacements at Lift Station 7, including removing existing infrastructure, installing a new 8-foot diameter wet well approximately 26 feet deep, constructing a new concrete driveway, installing new pumps, electrical panels, generator, fencing, water services, and associated piping and force main connections. The drawings, prepared by Barnes, Ferland and Associates, Inc. in May 2025, provide detailed civil, electrical, and structural plans for a complete lift station renovation, with a bid number yet to be finalized and a project number of 7015.
The project includes multiple technical components such as a new Flygt NP 3127 submersible pump system, a generator pad, electrical rack, water services, and comprehensive site improvements. The design incorporates specific technical requirements including a 6" discharge piping, force main connections, and detailed erosion control measures. The construction will require careful utility coordination, dewatering plans, and adherence to City of Daytona Beach Utilities Department standards. The project also includes provisions for temporary bypass pumping to maintain continuous wastewater service during construction, with a recommended sequence of work that ensures minimal disruption to existing infrastructure.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2558ITB_-_Lift_Station_7_Repairs_and_Upgrades.pdf | ||
| Project_References_LS_7.docx | DOCX document | |
| LS_No_7_Bid_Set_-_Technical_Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTENTION IS DIRECTED TO THE FACT THAT THESE
PLANS MAY HAVE BEEN REDUCED IN SIZE BY
REPRODUCTION. THIS MUST BE CONSIDERED WHEN
OBTAINING SCALED DATA. DIMENSION INFORMATION
SHOULD NOT BE OBTAINED BY SCALING THE PLANS.
CALL 48 HOURS
BEFORE YOU DIG
IT'S THE LAW!
DIAL 811
SUNSHINE STATE ONE CALL OF FLORIDA, INC.
Know what's below.
Call before you dig.
Monday, February 17, 2025 9:51:51 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 G-100.dwg
VICINITY MAP
NTS
PREPARED BY:
CITY OF DAYTONA BEACH
LIFT STATION NO. 7 REPAIRS AND UPGRADES
CONSTRUCTION DRAWINGS FOR
PROJECT # 7015
BID # XXXX
ZONE 6
MAY 2025
ENGINEER OF RECORD
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
MAY 2025 - BID SET
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100, ORLANDO, FL 32803
PH: (407) 896-8608 ENGINEERING REGISTRY NO. 6899
CITY OF DAYTONA BEACH UTILITIES DEPARTMENT
125 BASIN STREET, SUITE 131
DAYTONA BEACH, FLORIDA 32114
UTILITIES DIRECTOR: SHANNON PONITZ
CITY MANAGER: DERIC C. FEACHER
ZONE 6: COMMISSIONER PAULA R. REED
ZONE 5: COMMISSIONER DANNETTE HENRY
ZONE 4: COMMISSIONER STACY CANTU
ZONE 3: COMMISSIONER QUANITA MAY
ZONE 2: COMMISSIONER KEN STRICKLAND
ZONE 1: COMMISSIONER MONICA PARIS
COMMISSIONERS
DERRICK L. HENRY
CITY MAYOR
VOLUSIA COUNTY
CITY OF DAYTONA BEACH
PROJECT LOCATION
INDEX OF DRAWINGS
SHT No DWG No DESCRIPTION
1 G-100 COVER SHEET
2 G-101 LEGEND, ABBREVIATIONS, UTILITY CONTACTS AND SCHEDULE OF VALUES
3 G-102 GENERAL NOTES
4 G-103 GENERAL NOTES
5 C-100 LIFT STATION 7 EXISTING SITE PLAN
6 C-101 LIFT STATION 7 DEMOLITION PLAN
7 C-102 LIFT STATION 7 PROPOSED SITE PLAN
8 C-103 LIFT STATION 7 PROPOSED OFFSITE PLAN
9 C-104 TEMPORARY ACCESS DRIVEWAY AND BYPASS PLAN
10 PS-100 LIFT STATION 7 PLAN, SECTION AND NOTES
11 D-100 CONSTRUCTION DETAILS
12 D-101 CONSTRUCTION DETAILS
13 D-102 CONSTRUCTION DETAILS
14 D-103 CONSTRUCTION DETAILS
15 D-104 CONSTRUCTION DETAILS
16 E-001 ELECTRICAL ABBREVIATIONS, LEGENDS AND NOTES
17 E-101 LIFT STATION PLAN VIEW
18 E-501 DETAILS
19 E-502 DETAILS
REMOVE EXISTING CONCRETE
SURFACE, GRAVEL DRIVEWAY,
CONCRETE DRIVEWAY
EXISTING PIPE TO BE REMOVED
EXISTING PIPE TO BE ABANDONED
TAPPING SLEEVE AND VALVE
LINE STOP ASSEMBLY
VALVE (TYP)
SLEEVE
CAP
LEGEND
LOT LINE
EASEMENT LINE
EXISTING FENCE
EXISTING BURIED ELECTRIC
EXISTING GAS
EXISTING OVER HEAD UTILITY
EXISTING RECLAIMED WATER MAIN
EXISTING BURRIED TELEPHONE
EXISTING SANITARY SEWER
EXISTING WATER MAIN
EXISTING CABLE TV
EXISTING FIBER OPTIC CABLE
RIGHT OF WAY LINE
EXISTING FORCE MAIN
EXISTING IRRIGATION
TEST HOLE (TH-1)IN PLACE (GROUT FILLED)
REMOVE AND REPLACE SIGNS
EXISTING STORM WATER PIPE
REMOVE AND REPLACE
CURB AND GUTTER
ABBREVIATIONS
TREE REPLACEMENT (TYP)
CI/ASCE 3802 SUBSURFACE UTILITY QUALITY LEVEL INDEX
1. QUALITY LEVEL A (QLA): UTILITY INFORMATION WHICH HAS BEEN VISUALLY VERIFIED, SURVEY LOCATED (BOTH HORIZONTALLY AND VERTICALLY) AND ACCURATELY REDUCED ONTO THE DRAWINGS. THIS IS TYPICALLY SHOWN AS A HV
VERIFICATION EXCAVATION HOLE.
2. QUALITY LEVEL B (QLB): UTILITY INFORMATION DERIVED BY MARKING THE APPROXIMATE SURFACE HORIZONTAL LOCATION OF UTILITY USING ELECTRONIC METHODS BY THE UTILITY OWNER. MARKINGS BY UTILITY OWNERS ARE ASSUMED TO BE LOCATED BY ELECTRONIC METHODS AND SEPARATE LOCATES WILL NOT BE PERFORMED BY THE ENGINEER. MARKING IS
SUBSEQUENTLY FIELD SURVEY LOCATED AND ACCURATELY REDUCED ONTO THE DRAWINGS.
3. QUALITY LEVEL C (QLC): UTILITY INFORMATION OBTAINED AS BELOW FOR QUALITY LEVEL D, PLOTTED TO CORRELATE WITH SURFACE UTILITY FEATURES WHICH HAVE BEEN FIELD VERIFIED, SURVEY LOCATED AND ACCURATELY REDUCED ONTO THE DRAWINGS. INCLUDED IN THIS CATEGORY ARE AERIAL UTILITY INFORMATION AND UTILITY DEPICTIONS, WHICH IN THE PROFESSIONAL OPINION OF THE SUBSURFACE UTILITY ENGINEER, REPRESENT THE MOST PROBABLE
APPROXIMATE HORIZONTAL LOCATION, TYPE AND / OR EXISTENCE OF A UTILITY.
4. QUALITY LEVEL D (QLD): UTILITY INFORMATION PLOTTED ON THE DRAWING BASED SOLELY ON RECORD INFORMATION, INDIVIDUAL RECOLLECTIONS OR THE EXISTENCE OF UTILITY SERVICE. IT SHALL BE NOTED THAT ALL INFORMATION SHOWN (OTHER THAN AT TEST HOLE LOCATIONS, SEE QLA ABOVE) WITH REFERENCE TO A UTILITIES SIZE, CAPACITY, MATERIAL COMPOSITION, CONDITION OR SERVICE STATUS SHALL BE CONSIDERED QLD EVEN THOUGH THE UTILITY MAY BE
PLOTTED AND LABELED QLC OR QLB.
NOTE: THIS DRAWING WAS PREPARED IN CONFORMANCE WITH ASCE STANDARD CE/ASCE 38-02 "AMERICAN SOCIETY OF CIVIL ENGINEERS STANDARD GUIDELINE FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY
DATA"
TYPICAL EXISTING UTILITY DESIGNATION
ALL EXISTING UTILITIES DEPICTED ON THESE DRAWINGS ARE QUALITY LEVEL B UNLESS NOTED OTHERWISE ON THE
EXISTING UTILITY LINE.
NO. 57 STONE
AC ASBESTOS CEMENT, AIR
CONDITIONER
ADPT ADAPTER
ALUM ALUMINUM
APPROX APPROXIMATELY
ARV AIR RELEASE VALVE ASSEM
ASPH ASPHALT
ASSEM ASSEMBLY
AUX AUXILIARY
BFO BURIED FIBER OPTIC
BFP BACKFLOW PREVENTER
BFV BUTTERFLY VALVE
BL BASE LINE
BLDG BUILDING
BM BENCHMARK
BO BLOW OFF
BOT BOTTOM
BV BALL VALVE
CB CATCH BASIN
C\C CENTER LINE TO CENTER
LINE
C&G CURB AND GUTTER
CIP CAST IRON PIPE
CL CENTER LINE
CLF CHAIN LINK FENCE
CM CONCRETE MONUMENT
CMP CORRUGATED METAL PIPE
CO CLEAN OUT
CONC CONCRETE
CONN CONNECT
CONST CONSTRUCT
CONT CONTINUATION
CORP CORPORATION
CV CHECK VALVE
CY CUBIC YARD
DBL DOUBLE
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DIP DUCTILE IRON PIPE
DWG DRAWING
DWY DRIVEWAY
ELEC ELECTRIC
EA EACH
ELEV ELEVATION
EOP EDGE OF PAVEMENT
ESMT EASEMENT
EXIST EXISTING
EXP JT EXPANSION JOINT
FDEP FLA DEPT OF ENVIRON
PROTECT
FDOT FLA DEPT OF TRANS
FA FLANGED ADAPTER
FF FINISH FLOOR
FCA FLANGED COUPLING
ADAPTER
FHA FIRE HYDRANT ASSEMBLY
FIG FIGURE
FLG FLANGE
FL FLOW LINE
FM FORCE MAIN
FT FEET
GA GAUGE
GAL GALLON
GALV GALVANIZED
GEN GENERATOR
GSP GALVANIZED STEEL PIPE
GM GAS MAIN
GPM GALLONS PER MINUTE
GV GATE VALVE
HDWL HEADWALL
HFCA HARNESSED FLANGE
COUPLING ADAPTER
HT HEIGHT
HP HORSE POWER
HORIZ HORIZONTAL
HWL HIGH WATER LEVEL
ID INSIDE DIAMETER
IN INCHES
INV INVERT
IP IRON PIPE
IR IRON ROD
JUNC JUNCTION
LAT LATERAL
LF LINEAR FEET
LS LIFT STATION
LT LEFT
LWL LOW WATER LEVEL
MAX MAXIMUM
MATL MATERIAL
MEG MATCH EXISTING GRADE
MES MITERED END SECTION
MFR MANUFACTURER
MGD MILLION GALLONS PER DAY
MH MANHOLE
MIN MINIMUM
MJ MECHANICAL JOINT
MOD MODIFIED
MOT MAINTENANCE OF TRAFFIC
NG NATURAL GROUND
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPT NATIONAL PIPE THREAD
NPW NON-POTABLE WATER
NTS NOT TO SCALE
OD OUTSIDE DIAMETER
OHU OVERHEAD UTILITY
O\O OUTSIDE TO OUTSIDE
OPER OPERATOR
OPNG OPENING
PAVT PAVEMENT
PB PULL BOX
PC POINT OF CURVATURE
PE PLAIN END
PG PAGE
PI POINT OF INTERSECTION
PH PHASE
PL PROPERTY LINE
POLY POLYETHYLENE
PP POWER POLE
PROP PROPOSED
PS PUMP STATION
PSI POUNDS PER SQUARE INCH
PT POINT OF TANGENCY
PV PLUG VALVE
PVC POLYVINYL CHLORIDE PIPE
QTY QUANTITY
RAD PT RADIUS POINT
R RADIUS
RJ RESTRAINED JOINT
R\R RAIL ROAD
RCP REINFORCED CONC PIPE
RED REDUCER
REINF REINFORCED
REQ REQUIRED
RESTR RESTRAINED
RPZ REDUCED PRESS ZONE
RT RIGHT
RW RECLAIMED WATER
R\W RIGHT OF WAY
SAN SANITARY SEWER
SB SOIL BORING
SCH SCHEDULE
SD STORM DRAIN
SECT SECTION
SF SQUARE FEET
SHT SHEET
SLV SLEEVE
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STA STATION
STD STANDARD
STL STEEL
SY SQUARE YARDS
SYS SYSTEM
TCE TEMP CONST EASE
TEL TELEPHONE
TEMP TEMPORARY
TH TEST HOLE
THK THICK
TOB TOP OF BANK
TS&V TAPPING SLEEVE AND
VALVE
TYP TYPICAL
UG UNDERGROUND
VCP VITRIFIED CLAY PIPE
VERT VERTICAL
VVH VERIFIED VERT & HORIZ
w/ WITH w/o WITH OUT
WL WATER LEVEL
WM WATER MAIN
W\M WATER METER
WP WALL PIPE
WRF WATER RECLAIM FACILITY
WS WATER SERVICE
WWF WELDED WIRE FABRIC
SCHEDULE OF VALUES
STRUCTURES AND EQUIPMENT
CONCRETE SIDEWALK
TEE
DESIGN ELEVATION
LIMITS OF CONSTRUCTION
60.00
UTILITY PIPE DESIGNATION
NOTE: TRACY SHIRAH WILL BE THE UTILITY DEPARTMENT'S MAIN POINT OF CONTACT FOR ANY DEWATERING OR WELL
POINT WORK. HER CONTACT NUMBER IS 386-671-8884 AND EMAIL SHIRAHTRACY@CODB.US.
TEMPORARY ACCESS DRIVEWAY
2 19
2021-34-02
MAY 2025
NDH
JAB
EJG
MAY 2025 - BID SET
LEGEND, ABBREVIATIONS, UTILITY
CONTACTS AND SCHEDULE OF VALUES
G-101
LINE IS 1 INCH
AT FULL SIZE = 34x22
(IF NOT SCALE ACCORDINGLY)
No. REVISIONS BY DATE
PROJECT DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DRAWING FILE:
PROJECT No.:
SCALE:
DRAWING No.
SHEET
___ OF ___AS NOTED SEE MARGIN
Monday, February 17, 2025 9:51:12 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 G-101.dwg
DESIGN ENGINEER
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100
ORLANDO, FL 32803
PH: (407) 896-8608
ENGINEERING REGISTRY NO. 6899
LIFT STATION NO. 7 REPAIRS AND UPGRADES
THE CITY OF DAYTONA BEACH
UTILITIES DEPARTMENT
S-1 Sanitary Sewer Notes P1.dwg
Jan-08
MAL
JMP
NTS
Jan-2024
S-1
S-2 Sanitary Sewer Notes P-2.dwg
Jan-08
MAL
JMP
NTS
Jan-2024
S-2
S-3 Sanitary Sewer Notes P-3.dwg
Jan-08
MAL
JMP
NTS
Jan-2024
S-3
S-4 Sanitary Sewer Notes P-4.dwg
Jan-08
MAL
JMP
NTS
Jan-2024
S-4
Revision Date:
Scale:
Drawn By:
Checked By:
Drawing Date:
Page No.:
Detail No.:
Revision Date:
Scale:
Drawn By:
Checked By:
Drawing Date:
Page No.:
Detail No.:
FY-2022
Revision Date:
Scale:
Drawn By:
Checked By:
Drawing Date:
Page No.:
Detail No.:
Revision Date:
Scale:
Drawn By:
Checked By:
Drawing Date:
Page No.:
Detail No.:
1. THE CITY'S UTILITIES DEPARTMENT SHALL BE GIVEN A MINIMUM OF 3 BUSINESS DAYS ADVANCE NOTICE (NOT
INCLUDING HOLIDAYS) PRIOR TO BEGINNING ANY SANITARY SEWER CONSTRUCTION.
2. A PERMIT SHALL BE REQUIRED PRIOR TO ENGAGING IN ANY DEWATERING ACTIVITIES, OR IN ACTIVITIES, OR IN ANY CONSTRUCTION ACTIVITY THAT CHANGES THE IMPERVIOUS AREA OF LAND. DEWATERING ACTIVITIES INCLUDE THE REMOVAL OF GROUND WATER FROM A CONSTRUCTION SITE, ENCLOSED VAULT, COFFERDAM, OR TRENCHERS, ALLOWING CONSTRUCTION OR MAINTENANCE TO BE ONE IN THE DRY, OR ANY ACTIVITY WHICH CHANGES THE IMPERVIOUS AREA OF LAND. SITE SPECIFIC DEWATERING PERMITS SHALL REQUIRE PAYMENT OF A PER ACRE FEE BASED ON THE SIZE OF THE DEVELOPMENT. GENERAL PURPOSE PERMITS SHALL REQUIRE AN ANNUAL FEE BASED ON A BI-ANNUAL SCHEDULE OF DEWATERING ACTIVITIES DISCHARGING DIRECTLY INTO THE CITY'S MS4 CONVEYANCE SYSTEM. DEWATERING PERMIT APPLICATIONS CAN BE FOUND AT https://www.codb.us/ FEES ARE SUBJECT TO ARTICLE 7, SECTION 7.2 OF THE LAND DEVELOPMENT CODE AND MUST BE SUBMITTED WITH THE PERMIT APPLICATION TO CITY OF DAYTONA BEACH STORM WATER COORDINATOR AT 125 BASIN STREET, SUITE 100, DAYTONA BEACH, FLORIDA 32114 PRIOR TO ANY USE OF MS4. FAILURE TO COMPLY WILL RESULT IN THE IMMEDIATE
TERMINATION OF ACCESS TO THE CITY'S MS4 SYSTEM.
3. MAINLINE TOLERANCES FOR SANITARY SEWER VERTICAL DEFLECTION SHALL BE NO MORE THAN 0.5" IN DEPTH AND
NOT EXCEEDING THREE (3) FEET IN LENGTH.
4. UPON COMPLETION, THE CONTRACTOR SHALL PROVIDE THE CITY UTILITIES DEPARTMENT WITH A CCTV INSPECTION LOG ON DVD AND A PRINTED REPORT FOR ALL GRAVITY MAINS AND LATERALS CONSTRUCTED. ALL WORK, WITH THE EXCEPTION OF FINAL GRADE ADJUSTMENT TO MANHOLES. BENCHES AND FLOW CHANNELS SHALL BE COMPLETED PRIOR TO COMMENCING THE CCTV INSPECTION. THE CONTRACTOR SHALL COORDINATE THE CCTV INSPECTION TIME WITH THE CITY UTILITY INSPECTOR PRIOR TO INITIATING THE WORK. FINAL PAVING SHALL NOT COMMENCE UNTIL APPROVAL IS RECEIVED FROM THE CITY UTILITY INSPECTOR. CCTV SEWER VIDEOS AND AS-BUILT DOCUMENTS MUST BE REVIEWED AND APPROVED BY THE EOR STATING COMPLIANCE WITH CITY STANDARDS PRIOR TO REVIEW BY THE CITY. CCTV MUST BE PERFORMED WITH CITY INSPECTOR AND/OR ENGINEER OF RECORD PRESENT.
5. SEWER LATERAL LOCATIONS SHALL BE MARKED ALONG THE OUTSIDE OF THE CURB WITH A SAW CUT "V" OR BY A
METAL TAB SET INTO THE PAVEMENT.
6. THE CONTRACTOR SHALL BE REQUIRED TO PIG ALL FORCE MAINS EQUAL TO OR GREATER THAN 6" IN DIAMETER AND PRIMARY TRANSMISSION MAINS LOCATED ON COLLECTOR AND ARTERIAL ROADWAYS. LAUNCHING AND EXTRACTION
POINTS SHALL BE DETERMINED BY THE CITY.
7. WITH RESPECT TO TIE-IN CONNECTIONS AND CORING OPERATIONS, THE CITY RESERVES THE RIGHT TO REQUIRE CONNECTIONS TO BE PERFORMED DURING PERIODS OF LOW FLOW (MIDNIGHT TO 6:00 A.M.) (IN ORDER TO MINIMIZE
SERVICE DISRUPTION TO EXISTING CUSTOMERS.
8. ALL WORK ON SANITARY SEWER FACILITIES OWNED OR PROPOSED TO BE OWNED BY THE CITY SHALL BE PERFORMED BY AN UNDERGROUND UTILITY CONTRACTOR OR GENERAL CONTRACTOR LICENSED IN THE STATE OF
FLORIDA AND REGISTERED WITH THE CITY.
9. UPON CONSTRUCTION COMPLETION AND ACCEPTANCE OF THE SYSTEM, IT IS THE DESIGN ENGINEER'S RESPONSIBILITY TO ENSURE THAT THE SYSTEM IS PROPERLY CERTIFIED AND ACCEPTED BY THE FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION AND AS-BUILTS ARE PROVIDED TO THE CITY'S UTILITIES
DEPARTMENT PRIOR TO ANY USE OF THE SYSTEM.
10. PLANS SHALL DIMENSION THE LOCATION OF ALL FORCE MAINS, VALVES, MANHOLES & LATERALS FROM THE
BASELINE OF CONSTRUCTION AND FROM THE RIGHT-OF-WAY LINE.
11. LANDSCAPE PLANS SHALL CLEARLY DEPICT THE LOCATION OF PLANTINGS RELATIVE TO THE LOCATION OF PUBLIC
UTILITIES AND STORM WATER INFRASTRUCTURE.
12. THE CITY'S AS-BUILT DRAWING REQUIREMENTS ARE ATTACHED TO THE BACK OF THE UTILITIES DEPARTMENT'S
STANDARD DETAILS.
13. ALL GRAVITY SANITARY SEWER MAINS SHALL BE A MINIMUM OF 8" DIAMETER.
14. COMMERCIAL SERVICE LATERALS SHALL BE GREEN AND A MINIMUM OF 6" IN DIAMETER. OR LARGER. ALL SINGLE FAMILY RESIDENTIAL SERVICE LATERALS SHALL BE 6" SINGLE SERVICES WITH CLEAN OUTS INSTALLED AT
PROPERTY LINES.
15. ALL GRAVITY SANITARY SEWER MAINS SHALL BE GREEN PVC SDR-26, ASTM D-3034, OR C-900 DR-18. IN PLACES WHERE A MINIMUM COVER OF 4 FEET CANNOT BE MAINTAINED OR IN DEPTHS OF 10 FEET OR GREATER (CUT TO INVERT) MAINS
SHALL BE C-900 DR-18.
16. FOR SINGLE FAMILY HOMES, SINGLE SIX INCH SEWER SERVICE LATERALS SHALL BE CONSTRUCTED AT EACH LOT OR UNIT AND LOCATED ON THE DOWNSTREAM SIDE OF THE LOT CENTER LINE. AT THE END OF SERVICES LATERALS INSTALL A LOCATIONS MARKER WITHA 3M ELECTRONICE MARKER SYSTEM (EMS) FULL RANGE MARKERS, WITH A 2"X4"X4' PRESSURE TREATED STAKE PAINTED GREEN VISIBLE FROM THE ROAD. RUBBER SEAL FITTINGS SHALL BE USED
ON ALL LINES. NO GLUED JOINTS ARE PERMITTED ON LATERALS.
17. FOR MULTI-FAMILY AND COMMERCIAL SITES, SIX INCH MINIMUM SEWER SERVICES AND CLEANOUTS SHALL BE
PROVIDED AS APPROVED BY THE CITY.
18. FORCE MAINS LESS THAN 18" MAY USE PVC C900 OR C905 DR-18. FORCE MAINS 18" AND LARGER SHALL BE DUCTILE IRON PIPE (D.I.P.), CLASS 350, EPOXY LINED. ALL NON DUCTILE IRON PIPE AND HORIZONTAL DIRECTIONAL DRILL FORCE MAINS SHALL HAVE A MINIMUM WORKING PRESSURE OF 160 PSI. THE CITY MAY REQUIRE A HIGHER PRESSURE RATING DEPENDING ON SITE CONDITIONS. INSIDE DIAMETER OF NON D.I.P. HORIZONTAL DIRECTIONAL DRILL PIPE SHALL MATCH THE INSIDE DIAMETER OF CONNECTING PIPES. DIRECTIONAL DRILLS SHALL HAVE FUSED MJ
ADAPTERS.
19. FORCE MAIN MINIMUM DEPTH OF COVER SHALL BE 48". ALL FORCE MAINS SHALL BE DISTINCTLY MARKED BY GREEN
STRIPES OR COLORED GREEN.
20. ALL FITTINGS, VALVES, ETC. SHALL BE DUCTILE IRON (MJ OR FLANGED) AND RESTRAINED. ALL FORCE MAINS SHALL USE THRUST RESTRAINT AS CALCULATED BY A PROGRAM AVAILABLE AT (EBAA.COM). THE RESTRAINED JOINT
LENGTHS SHALL BE SHOWN ON THE PLANS PROVIDED BY THE ENGINEER OF RECORD.
21. ALL RESTRAINED PIPE BELL JOINTS SHALL USE BELL RESTRAINTS. GRIPPER TYPE GASKETS CAN BE USED FOR
DUCTILE IRON PIPE JOINTS. CONCRETE THRUST BLOCKS ARE NOT PERMITTED.
22. AS A GENERAL RULE, THE NUMBER OF JOINTS SHALL BE LIMITED WHENEVER POSSIBLE. IN SPECIAL CASES WHERE A POINT REPAIR TO AN 8" TO 12" PVC SEWER MAIN IS REQUIRED, THE PROPER RIGID WRAP AROUND SLEEVE MAY BE
ALLOWED BY CITY SPECIAL APPROVAL.
23. ALL IN-LINE SANITARY SEWER FORCE MAIN VALVES SHALL BE FULL PORT PLUG VALVES UNLESS OTHERWISE NOTED.
VALVES SHALL BE INSTALLED AT EACH END OF THE FORCE MAIN AND ON STUB OUTS.
24. ALL C-900 PVC DR-18 PIPE REQUIREMENTS REFERENCE THE C-900 STANDARDS.
25. MINIMUM GRAVITY SANITARY SEWER SLOPES ARE AS FOLLOWS: 8" PIPE 0.40%, 10" PIPE 0.28%, 12" PIPE 0.22%, 15" PIPE 0.15%, OR OTHERWISE NOTED BY UTILITIES DEPT. MANHOLES SHALL HAVE AT LEAST 1 TENTH FALL FROM
INCOMING INVERT OR INVERTS TO THE OUT GOING INVERT IN THE MANHOLE.
26. GRAVITY SANITARY SEWER LINE CONSTRUCTION SHALL BE ACCOMPLISHED BY THE USE OF A LASER
INSTRUMENT UNLESS ANOTHER METHOD IS APPROVED BY THE CITY.
27. DURING PIPE INSTALLATION DEWATER THE GROUND SUFFICIENTLY TO KEEP THE GROUNDWATER ELEVATION
A MINIMUM OF 6" BELOW THE PIPE BEING INSTALLED WITHIN THE AREA OF THE TRENCH.
28. ALL PIPES SHALL BE INSTALLED ON A FIRM FOUNDATION. SOFT OR SPONGY BEDDING FOR PIPES IS NOT ACCEPTABLE.
ANY UNSUITABLE MATERIAL SHALL BE REMOVED AND REPLACED WITH A DRY, COMPACTED, GRANULAR MATERIAL
SATISFACTORY TO THE CITY.
29. ON ALL EXCAVATION AND BACKFILLING THE CONTRACTOR SHALL PROVIDE ADEQUATE SHEETING AND BRACING
IN ORDER TO PROVIDE A SAFE WORKING ENVIRONMENT.
30. ALL TRENCHES SHALL BE BACKFILLED WITH ACCEPTABLE MATERIAL AND COMPACTED TO THE SPECIFIED MINIMUM COMPACTION (95% IN UNPAVED AREAS AND 98% IN PAVED AREAS) AND THE OPTIMUM DENSITY BASED ON THE AASHTO
T-180 MODIFIED PROCTOR TEST.
31. ALL GASKETS SHALL BE LUBRICATED BEFORE INSTALLATION.
32. THE CONTRACTOR SHALL INSTALL A #12-GAUGE MINIMUM COPPER TRACER WIRE TAPED TO THE TOP OF THE PIPE AT INTERVALS NO GREATER 4 FEET. COPPER WIRE SHALL HAVE A MIN. TENSILE STRENGTH/BREAK LOAD OF 452 LBS. AND REQUIRES APPROVAL BY THE CITY FOR THE FULL LENGTH OF ALL SEWER FORCE MAINS. THE PIPE LOCATOR TAPE SHALL BE INSTALLED BETWEEN 15" AND 24" BELOW FINISHED GRADE OR AS DIRECTED BY THE MANUFACTURER. THE TAPE SHALL BE COLOR CODED GREEN FOR FORCE MAINS. LOCATER WIRE SHALL TERMINATE AT A LOCATION AND IN
MANNER CONVENIENT FOR THE CITY LOCATER STAFF.
33. TRACER WIRE SHALL BE TESTED FOR CONTINUITY UNDER SUPERVISION OF A CITY REPRESENTATIVE AFTER
INSTALLATION.
34. ALL SEWER LINES CONSTRUCTED OUTSIDE OF PUBLIC RIGHT-OF-WAYS WITHIN SIDE YARDS, BACKYARDS, AND OTHER POORLY ACCESSIBLE AREAS SHALL BE CONSTRUCTED OF GREEN C-900 PVC. ABSOLUTELY NO USE OF PLASTIC
STYRENE FITTINGS SHALL BE ALLOWED.
35. ALL LOCAL COLLECTION SANITARY SEWER MANHOLES SHALL BE PRECAST WITH A MINIMUM INSIDE DIAMETER OF 4 FEET. MANHOLES OVER 6 FEET DEEP SHALL HAVE A MINIMUM 4 FT TALL PRE-CAST BOTTOM SECTION.
36. STANDARD MANHOLES SHALL BE LOCATED AT INTERVALS NOT EXCEEDING 400 FEET.
37. MANHOLE RIMS SHALL BE FLUSH WITH THE FINISH GRADE ELEVATION IN PAVED AREAS AND A MINIMUM OF 0.5 FEET AND MAXIMUM OF 1.0 FOOT ABOVE GRADE IN UNPAVED AREAS. ALL MANHOLES SHALL HAVE A INFLOW DEFENDER INFLOW DISH (RAIN/STORMWATER DISH) INSTALLED UNDER MANHOLE LID PRIOR TO INSPECTION.
38. THE CONTRACTOR SHALL CONSTRUCT SANITARY SEWER MANHOLES IN SUCH A WAY THAT SEWER LINES DO NOT
INTERSECT SEALED JOINTS BETWEEN SECTIONS OF THE MANHOLE.
39. INDIVIDUAL SANITARY SERVICES SHALL NOT BE CONNECTED DIRECTLY INTO MANHOLES AND MUST BE CONNECTED
TO SEWER MAINS BY USE OF WYE CONNECTIONS UNLESS OTHERWISE APPROVED BY THE CITY.
40. SANITARY SEWER DROP MANHOLES SHALL ONLY BE USED UNDER SPECIAL CONDITIONS AS APPROVED BY THE CITY.
DROPS ARE REQUIRED FOR SEWERS ENTERING MANHOLES AT 2.0' OR ABOVE THE THE BOTTOM INVERT OF THE
MANHOLE.
41. SANITARY SEWER MANHOLES WITH SEWER FORCE MAINS DISCHARGING DIRECTLY INTO THEM SHALL BE FIBERGLASS OR POLY-ETHYLENE LINED. RETRO-FITTING OF MANHOLES WITH LINERS IS REQUIRED WHEN NEW CONNECTIONS ARE MADE. FIBERGLASS SHALL BE A MINIMUM 1/2" THICK UNLESS APPROVED OTHERWISE BY THE CITY. OTHER LINING METHODS AND MATERIALS MAY BE CONSIDERED ON A CASE BY CASE BASIS. UNDER CIRCUMSTANCES WHERE HYDROGEN SULFIDE IS A SIGNIFICANT CONCERN, MANHOLES UPSTREAM AND/OR DOWNSTREAM OF THE FORCE MAIN
TIE-IN MAY BE REQUIRED TO HAVE LININGS INSTALLED.
42. EZ-WRAP PLASTIC, AS MANUFACTURED BY PRESS SEAL GASKET CORPORATION, SHALL BE USED ON THE OUTSIDE OF ALL MANHOLE AND WETWELL JOINTS. APPLY ONE LAYER OF 9" WRAP CENTERED ON EACH JOINT. A CITY INSPECTOR
SHALL INSPECT ALL JOINT SEALS PRIOR TO BACKFILLING OPERATIONS.
43. CONTRACTOR FOR DEVELOPMENTS WITH THE POTENTIAL TO DISCHARGE INDUSTRIAL OR COMMERCIAL WASTE INTO THE SEWER SYSTEM SHALL CONSTRUCT AND MAINTAIN AT THE OWNER'S EXPENSE A SUITABLE CONTROL MANHOLE OR MANHOLES DOWNSTREAM OF ANY TREATMENT, STORAGE, OR OTHER APPROVED WORKS, PRIOR TO THE CITY'S COLLECTION SYSTEM TO FACILITATE OBSERVATION, MEASUREMENT, AND SAMPLING OF ALL WASTE, INCLUDING
ALL DOMESTIC SEWAGE FROM THE ESTABLISHMENT.
44. CONTROL MANHOLE OR MANHOLES SHALL BE CONSTRUCTED AT LOCATIONS EASILY ACCESSIBLE AT ALL TIMES TO
CITY PERSONNEL FOR SAMPLING.
45. SANITARY SEWER LIFT STATIONS AND FORCE MAINS SHALL BE APPROVED BY THE CITY. LIFT STATIONS SHALL BE
CONSTRUCTED WITH A MINIMUM WET WELL AS SHOWN IN THE LIFT STATION DETAIL.
46. IT SHALL BE THE RESPONSIBILITY OF THE DESIGN ENGINEER TO PREPARE AND SUBMIT FLOTATION CALCULATIONS TO
SIZE THE BASE OF THE WET WELL, AND ANY MANHOLES AS DEEMED NECESSARY BY THE CITY.
47. ALL FITTINGS SHALL MEET THE MINIMUM RESTRAINT REQUIREMENTS PER ANSI/AWWA/DIPRA, AND ALL PRESSURE PIPES
UNDER ROADWAYS SHALL BE RESTRAINED.
48. LOW PRESSURE SANITARY SEWER SYSTEMS ARE NOT PERMITTED IN RESIDENTIAL OR COMMERCIAL SUBDIVISIONS.
49. SANITARY SEWER SYSTEMS SHALL BE RE-TELEVISED IN THEIR ENTIRETY, CITY REVIEWED AND APPROVED 30 DAYS
PRIOR TO THE MAINTENANCE BOND BEING RELEASED.
L = SD P
WHERE:
L = ALLOWABLE LEAKAGE, IN GALLONS PER HOUR
S = LENGTH OF PIPE TESTED, IN FEET
D = NOMINAL DIAMETER OF PIPE, IN INCHES
P = AVERAGE TEST PRESSURE DURING THE LEAKAGE TEST,
IN POUNDS PER SQUARE INCH (GAUGE)
AVERAGE
TEST
PRESSURE
0.25 0.23
0.37
0.32
0.28 0.30
0.34 0.36
0.45
0.39 0.42
0.48
0.30 0.34
0.50
0.40 0.37
0.43
0.47 0.45
0.60 0.56 0.52
0.64
0.45 0.50
0.75
0.59 0.55
0.64
0.71 0.68
0.90 0.84 0.78
0.95 6 8
0.67 0.60
1.00
0.85 0.80 0.74
0.95 0.90
1.20 1.12 1.04
1.27
0.75 0.84
1.24
0.92 0.99 1.06
1.19 1.13
1.50
1.30 1.40
1.59
0.90 1.01 1.10 1.19 1.28 1.35 1.42 1.49 1.56 1.69 1.80 1.91
1.05 1.18
1.74
1.29 1.39 1.48 1.58 1.66
2.10
1.82 1.97
2.23
(PSI) 16
1.20 1.34
1.99
1.47 1.59 1.70 1.80 1.90
2.08 2.25 2.40 2.55
1.35 1.51 1.66 1.79 1.91 2.03 2.14 2.24 2.34 2.53 2.70 2.87
3.18
1.50 1.68
2.49
1.84 1.98 2.12 2.25 2.37
3.00
2.60 2.81
2.01 1.80
2.99 2.85 2.70 2.55 2.38 2.21
3.37 3.12
3.60 3.82
2.52 2.25
3.73
2.76 2.98 3.19 3.38 3.56
4.50
3.90 4.21
4.78
2.70 3.02
4.48
3.31 3.58 3.82 4.05 4.27
5.41
4.68 5.06
5.73
3.15 3.53
5.23
3.86 4.17 4.46 4.73 4.99
5.46 5.90 6.31 6.69
4.03
5.98
4.41 4.77 5.09 5.41 5.70
7.21
6.24 6.74
7.64
3.60
4.05 4.53 4.97 5.36 5.73 6.03 6.41 6.72
8.11 8.60
7.58 7.02
4.50 5.04
7.47
5.52 5.96 6.37 6.76 7.12
7.80 8.43
9.56 9.01
4.80 5.37
7.97
5.88 6.36 6.80 7.21 7.60
9.61
8.32 8.99
10.19
(PSI)
PRESSURE
AVERAGE
TEST
ALLOWABLE LEAKAGE PER 1000 FT. OF PIPELINE * -GPH
NOMINAL PIPE DIAMETER - INCHES
133,200
1. THE CONTRACTOR SHALL EMPLOY AN INDEPENDENT TESTING LABORATORY AT HIS OWN EXPENSE TO INSURE COMPACTION OF ALL FILL MATERIAL IS COMPLETED PROPERLY. TESTS SHALL BE DONE ONE FOOT ABOVE THE PIPE AND AT ONE FOOT VERTICAL INTERVALS UNTIL FINAL GRADE IS REACHED.
TESTS SHALL BE COMPLETED A MINIMUM FREQUENCY OF ONE SET OF TESTS EACH 300 FOOT LENGTH OF PIPING AND ONE ADDITIONAL SET OF TESTS AT EVERY MANHOLE. IDENTIFICATION OF TEST
LOCATIONS SHALL BE CLEARLY INDICATED ON TEST REPORTS. TEST RESULTS SHALL BE
FORWARDED PROMPTLY TO THE CITY'S DESIGNATED SITE INSPECTOR.
2. ALL TESTING REQUIRED BY THE CITY SHALL BE PAID FOR BY THE CONTRACTOR/DEVELOPER.
3. THE CITY OF DAYTONA BEACH RESERVES THE RIGHT TO REQUIRE THE DEVELOPER TO PERFORM
VACUUM TESTING OF ALL SANITARY MANHOLES AND TO AIR TEST SEWER MAINS.
4. ALL PROPOSED SEWER FORCE MAINS SHALL BE FLUSHED, PRESSURE TESTED AND CLEARED FOR
SERVICE IN ACCORDANCE WITH THE FLORIDA DEPARTMENT OF ENVIROMENTAL PROTECTION
PROTECTION REQUIREMENTS. THE CONTRACTOR SHALL NOTIFY THE CITY'S DESIGNATED SITE
INSPECTOR AT LEAST 3 BUSINESS DAYS PRIOR TO BEGINNING A FULL-DIAMETER FLUSH OF THE MAINS
FOR PRESSURE TESTING.
5. SANITARY SEWER FORCE MAINS SHALL BE PRESSURE TESTED TO 100 PSI FOR 2 HOURS WITH
ALLOWABLE LEAKAGE BASED ON THE TABLE BELOW.
* IF THE PIPELINE UNDER TEST CONTAINS SECTIONS OF VARIOUS DIAMETERS, THE ALLOWABLE LEAKAGE WILL BE THE
SUM OF THE COMPUTED LEAKAGE FOR EACH SIZE.
FY-2024-2025 FY-2024-2025 FY-2024-2025 FY-2024-2025
GENERAL NOTES
3 19
2021-34-02
MAY 2025
NDH
JAB
EJG
MAY 2025 - BID SET
G-102
LINE IS 1 INCH
AT FULL SIZE = 34x22
(IF NOT SCALE ACCORDINGLY)
No. REVISIONS BY DATE
PROJECT DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DRAWING FILE:
PROJECT No.:
SCALE:
DRAWING No.
SHEET
___ OF ___AS NOTED SEE MARGIN
Monday, February 17, 2025 9:51:12 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 G-102.dwg
DESIGN ENGINEER
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100
ORLANDO, FL 32803
PH: (407) 896-8608
ENGINEERING REGISTRY NO. 6899
LIFT STATION NO. 7 REPAIRS AND UPGRADES
*ALL WORK AND REQUIREMENTS FROM THE NOTES IN THIS PAGE SHALL BE A REQUIREMENT OF THE CONTRACT AND EXECUTED BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE CITY OF DAYTONA BEACH.
9. LOCATIONS, ELEVATIONS AND DIMENSIONS OF EXISTING UTILITIES AND STRUCTURES ARE APPROXIMATE. WHILE CONSIDERABLE EFFORT HAS BEEN MADE BY THE OWNER, THE SURVEYOR, THE VARIOUS UTILITY COMPANIES AND THE ENGINEER TO ACCURATELY LOCATE EXISTING LINES AND APPURTENANCES, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL UTILITY AND STRUCTURE LOCATIONS, ELEVATIONS AND DIMENSIONS BY UTILIZING EXPLORATORY EXCAVATION, WHICH SHALL BE MADE 7 DAYS OR 1000 FEET IN ADVANCE OF THE WORK, WHICHEVER IS GREATER. IF THERE IS A POTENTIAL CONFLICT, THE CONTRACTOR IS TO NOTIFY THE ENGINEER IMMEDIATELY. NO CLAIMS FOR DELAYS WILL BE PAID UNLESS THIS PROCEDURE HAS BEEN FULLY FOLLOWED. ANY DAMAGE TO UTILITIES, STRUCTURES AND/OR SERVICES SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE, IN A MANNER APPROVED BY AND COORDINATED WITH THE UTILITY OWNER. CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING THE UTILITY OWNER OF ANY UNINTENDED INTERRUPTION TO SERVICE OR DAMAGE TO EXISTING STRUCTURES OR UTILITIES.
10. IMMEDIATELY AT ONSET OF CONSTRUCTION, CONTRACTOR SHALL FIELD VERIFY HORIZONTAL AND VERTICAL LOCATIONS OF ALL EXISTING UTILITIES CRITICAL TO COMPLETING THE PROJECT (INCLUDING WATER, SEWER, RECLAIMED WATER, POWER, TELEPHONE, GAS, FIBER OPTIC AND CABLE TV) AND SHALL EVALUATE POTENTIAL CONFLICTS IN A WRITTEN REPORT. ANY CONFLICTS SHALL BE REPORTED TO
ENGINEER/OWNER IMMEDIATELY UPON DISCOVERY AND DETAILED IN THE REPORT.
11. CONTRACTOR SHALL COORDINATE WITH ALL OTHER UTILITY OWNERS FOR RESOLUTION OF CONFLICTS. CONTRACTOR SHALL HAVE 48 HOURS TO DETERMINE THE RESOLUTION OF ANY UNKNOWN OR UNFORESEEN CONFLICTS. COSTS INCURRED SHALL BE BORNE BY THE UTILITY OWNER AND/OR CONTRACTOR AND NO CLAIMS MAY BE MADE AGAINST ORANGE COUNTY OR THE ENGINEER FOR THESE CONFLICTS. NO ADDITIONAL COMPENSATION SHALL BE MADE FOR THE PERIOD OF TIME TO RESOLVE ANY CONFLICTS.
12. SUPPORT AND PROTECT ALL EXISTING UTILITIES. CONTRACTOR SHALL CONTACT UTILITY OWNERS FOR LOCATION OF ALL EXISTING FACILITIES. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH UTILITY OWNERS AND FOR PROVIDING TEMPORARY SUPPORT FOR THE UTILITY POLES, ANCHOR GUYS, AND ALL OTHER UTILITIES DURING CONSTRUCTION.
13. WHEN WORKING IN THE VICINITY OF FIBER OPTICS AND/OR GAS MAINS, THE CONTRACTOR SHALL NOTIFY THE UTILITY OWNER SEVEN (7) DAYS PRIOR TO ANY CONSTRUCTION. EXTREME CAUTION SHALL BE
EXERCISED IN AREAS OF FIBER OPTICS AND GAS MAINS.
14. EXISTING DRAINAGE PIPING AND/OR STRUCTURES TO BE SUPPORTED OR REMOVED AND REPLACED AS REQUIRED TO ACCOMMODATE GRAVITY SEWER MAIN INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR CONTROLLING WATER LEVELS IN THE STORM WATER SYSTEM IF NECESSARY, FOR CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER.
15. THE CONTRACTOR SHALL FIND AND MAINTAIN HIS OWN EQUIPMENT AND MATERIAL STORAGE YARD AT NO COST TO THE CITY.
16. EXISTING CURB, SIDEWALK AND/OR CONCRETE DRIVES SHALL BE REMOVED AND REPLACED AS REQUIRED TO ACCOMMODATE GRAVITY SEWER MAIN INSTALLATION. ALL CONCRETE TO BE REMOVED SHALL BE SAW CUT AT THE NEAREST GOOD JOINT. CURB/GUTTER SHALL BE SAW CUT BETWEEN ASPHALT AND CONCRETE PRIOR TO REMOVAL. ALL SAW CUTTING SHALL BE WET CUT TO CONTROL DUST. ALL CURB, SIDEWALK AND/OR CONCRETE DRIVES DAMAGED OUTSIDE NORMAL TRENCH WIDTH CONSTRUCTION SHALL BE REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
17. PROTECT EXISTING IMPROVEMENTS TO THE MAXIMUM EXTENT POSSIBLE. RESTORE ALL EXISTING IMPROVEMENTS AND DISTURBED AREAS TO ORIGINAL CONDITION. PAVEMENT TO BE RESTORED IN ACCORDANCE WITH THE PAVEMENT RESTORATION DETAILS SHOWN ON THE CONSTRUCTION DETAIL SHEETS. ALL DAMAGED MAILBOXES, IRRIGATION SYSTEMS, SOD, LANDSCAPING, FENCING, SIDEWALK, ROADWAY PAVEMENT AND OTHER IMPROVEMENTS SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION. PROJECT INCLUDES BRICK, BLOCK, AND DECORATIVE MAIL BOXES, ORNAMENTAL LANDSCAPING STRUCTURES SUCH AS BLOCK AND BRICK RETAINING WALLS, PLANTER STRUCTURES, BRICK PAVERS, AND OTHER FEATURES THAT SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION IF DAMAGED
DURING CONSTRUCTION.
18. NO VALVE BOXES, METERS, PORTIONS OF MANHOLES, OR OTHER APPURTENANCES OF ANY KIND RELATING TO ANY UNDERGROUND UTILITIES SHALL BE LOCATED IN ANY PORTION OF A CURB-AND-GUTTER SECTION. CONTRACTOR SHALL ADVISE ENGINEER IMMEDIATELY UPON DISCOVERY OF A POTENTIAL CONFLICT.
19. THE DISPOSAL OF ANY EXCESS EARTH WORK MATERIAL SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
20. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER SALVAGE AND/OR DISPOSAL OF ALL MATERIALS AND EQUIPMENT IN ACCORDANCE WITH THE SPECIFICATIONS AND AS DIRECTED BY THE CODB.
21. EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE PLACED PRIOR TO, OR AS THE FIRST STEP IN CONSTRUCTION AND ARE THE MINIMUM REQUIRED. CONTRACTOR SHALL FURNISH ADDITIONAL CONTROLS AS NEEDED AT NO ADDITIONAL COST. MATERIALS FROM WORK ON THIS PROJECT SHALL BE CONTAINED AND NOT ALLOWED TO COLLECT ON ANY OFF PERIMETER AREAS OR IN WATERWAYS. SILK SCREENS, HAY BALES, AND TURBIDITY BARRIERS MUST REMAIN IN PLACE AND IN GOOD CONDITION AT ALL LOCATIONS IN PLANS OR AS REQUIRED UNTIL THE CONTRACT IS COMPLETED AND SOILS ARE STABILIZED AND VEGETATION IS ESTABLISHED. MEASURES SHOWN ON THE PLANS ARE MINIMUM REQUIRED, AND THE CONTRACTOR SHALL ENSURE THAT THERE IS NO DIRECT OR INDIRECT DISCHARGE OF
CONSTRUCTION MATERIALS IN TURBID WATERS TO OFF SITE AREAS OR WATERWAYS.
22. CONTRACTOR'S USE OF THE PREMISES SHALL BE CONFINED TO THE LIMITS OF THE EXISTING RIGHT OF WAY AND/OR EASEMENTS. ALL PUBLIC AND PRIVATE PROPERTY AFFECTED BY THE CONSTRUCTION SHALL BE PROTECTED WHERE POSSIBLE. ALL AREAS DISTURBED AS PART OF THIS WORK SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION AT NO ADDITIONAL COST TO THE OWNER. ALL EXISTING SODDED AREAS DISTURBED DURING THE CONSTRUCTION SHALL BE REPLACED WITH THE SAME TYPE OF SOD IN CONFORMANCE WITH THE STANDARD SPECIFICATIONS. FIELD ENGINEER SHALL APPROVE THE REMOVAL AND REPLACEMENT OF EXISTING IRRIGATION SYSTEMS, AS REQUIRED, AT NO ADDITIONAL COST TO THE COUNTY OR PROPERTY OWNER. PROPER TEMPORARY ADJUSTMENTS SHALL BE DONE AT SUCH TIME TO MAINTAIN IRRIGATION SYSTEMS FROM BEING INTERRUPTED FOR EXTENDED PERIODS DURING CONSTRUCTION. CONTRACTOR SHALL REPAIR OR REPLACE, AT NO ADDITIONAL COST TO THE OWNER, ALL TREES, LANDSCAPING AND SHRUBS. ALL ITEMS THAT ARE REPLACED SHALL BE OF LIKE SIZE AND SPECIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTENANCE OF ALL NEWLY PLANTED
GRASS OR VEGETATION UNTIL WELL ESTABLISHED AND ACCEPTED BY THE CITY.
EXCAVATION AND SHORING
23. ALL EXCAVATIONS SHALL CONFORM TO THE REQUIREMENTS OF THE OSHA TRENCH SAFETY ACT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER STORAGE AND/OR DISPOSAL OF ALL EXCESS OR
UNSUITABLE EXCAVATED MATERIAL.
24. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY TEMPORARY CONTROLS AND/OR STRUCTURES REQUIRED TO MAINTAIN SUITABLE AND SAFE WORKING CONDITIONS AT ALL TIMES. SUCH ITEMS SHALL BE
REMOVED ONCE THAT PORTION OF WORK HAS BEEN COMPLETED.
25. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE STABILITY OF EMBANKMENTS AND SHALL REPLACE ANY PORTION WHICH, IN THE OPINION OF THE CODB, HAS BECOME DISPLACED DUE TO EROSION OR DUE
TO CARELESSNESS OR NEGLIGENCE ON THE PART OF THE CONTRACTOR.
26. WHERE REQUIRED, AT NO ADDITIONAL COST TO THE CITY, THE CONTRACTOR SHALL USE TEMPORARY SHEETING OR TRENCH BOXES TO MINIMIZE THE SIZE OF EXCAVATIONS AND PROTECT EXISTING ROADWAYS, UTILITIES AND OTHER FACILITIES OR AS NEEDED TO REMAIN WITHIN THE LIMITS OF CONSTRUCTION.
27. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND IMPLEMENTING THE NPDES STORMWATER PERMIT THROUGH FDEP. THIS PERMIT SHOULD BE APPLIED FOR AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. THE CONTRACTOR MUST SEND THE UTILITY DEPARTMENT PROOF THAT THIS PERMIT HAS BEEN APPLIED FOR AND ACCEPTED BY FDEP PRIOR TO ANY WORK ACTIVITIES.
28. THE CONTRACTOR TO REQUEST CITY APPROVAL WITH ALL EROSION CONTROL IN PLACE PRIOR TO ANY CONSTRUCTION ACTIVITIES STARTING ON THE SITE.
29. THE CONTRACTOR TO SUBMIT A DEWATERING PLAN FOR THIS PROJECT PRIOR TO ANY CONSTRUCTION ACTIVITIES STARTING ON THE SITE.
PROJECT GENERAL NOTES
1. ALL UTILITIES FACILITIES CONSTRUCTION CONNECTING TO THE CITY OF DAYTONA BEACH PUBLIC UTILITIES SYSTEM SHALL CONFORM TO THE CITY OF DAYTONA BEACH UTILITIES STANDARDS AND
CONSTRUCTION SPECIFICATIONS MANUAL, AND BE ONE OF THE APPROVED PRODUCTS.
2. BENCHMARK LOCATIONS AND ELEVATIONS ARE SHOWN IN THE PLANS AS REPRESENTED BY THE SURVEYOR AT THE TIME OF SURVEY. CONTRACTOR SHALL VERIFY ITS CORRECTNESS AT THE TIME OF CONSTRUCTION AND INSTALL HIS OWN TEMPORARY BENCHMARKS. ANY DISCREPANCIES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CODB UTILITIES.
3. ALL NORTHING AND EASTING COORDINATES ARE BASED ON THE STATE PLANE COORDINATE SYSTEM. STATIONING IS FOR REFERENCE ONLY.
4. COORDINATION AND COMMUNICATIONS WITH THE CODB STAFF SHALL BE MADE THROUGH THE CITY'S UTILITY DEPARTMENT.
5. PRIOR TO THE START OF ANY WORK, THE CONTRACTOR SHALL PLAN AND SCHEDULE THE SEQUENCE OF WORK IN ORDER TO PREVENT
UNNECESSARY DELAYS OR COSTS ASSOCIATED WITH CRITICAL PATH ITEMS OF THE WORK.
6. THE CONTRACTOR SHALL NOTIFY ALL UTILITY OWNERS NO LESS THAN FORTY-EIGHT 48 HOURS PRIOR TO THE START OF ANY CONSTRUCTION.
7. THE CONTRACTOR SHALL BRING ANY DESIGN DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE ENGINEER, IN WRITING, PRIOR TO CONSTRUCTION OR AS SOON AS DISCOVERED.
8. THE OWNER SHALL FURNISH THE FDEP WASTEWATER PERMIT(S). THE CONTRACTOR SHALL OBTAIN ALL OTHER PERMITS REQUIRED FOR THE PROJECT. THE CONTRACTOR SHALL BECOME FAMILIAR WITH AND ABIDE BY ALL PERMIT CONDITIONS, INSPECTION SCHEDULES, AND OTHER RELEVANT REGULATORY AGENCY RULES AND SPECIAL CONDITIONS.
GENERAL NOTES
4 19
2021-34-02
MAY 2025
NDH
JAB
EJG
MAY 2025 - BID SET
G-103
LINE IS 1 INCH
AT FULL SIZE = 34x22
(IF NOT SCALE ACCORDINGLY)
No. REVISIONS BY DATE
PROJECT DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DRAWING FILE:
PROJECT No.:
SCALE:
DRAWING No.
SHEET
___ OF ___AS NOTED SEE MARGIN
Monday, February 17, 2025 9:51:12 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 G-102.dwg
DESIGN ENGINEER
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100
ORLANDO, FL 32803
PH: (407) 896-8608
ENGINEERING REGISTRY NO. 6899
LIFT STATION NO. 7 REPAIRS AND UPGRADES
te
SV
APPARENT EASEMENT
APPARENT EASEMENT
AP
PA
RE
NT
E
AS
EM
EN
T
AP
PA
RE
NT
E
AS
EM
EN
T
AP
PA
RE
NT
E
AS
EM
EN
T
AP
PA
RE
NT
E
AS
EM
EN
T
AP
PA
RE
NT
E
AS
EM
EN
T
AP
PA
RE
NT
E
AS
EM
EN
T
AP
PA
RE
NT
V
AC
AT
ED
R /W
AP
PA
RE
NT
R /W
APPARENT R/W
APPARENT R/W
AP
PA
RE
NT
E
AS
EM
EN
T UNKNOWN BOX CULVERT
UNKNOWN BOX CULVERT
UNKNOWN BOX CULVERT
TV
H Y D
EH
TS
THH
C O
ARV
RCW
RW
R
FO
G
COM
TRF
PX
te
FOH
CTV
E
T
5 19
2021-34-02
MAY 2025
NDH
JAB
EJG
MAY 2025 - BID SET
LIFT STATION 7
EXISTING SITE PLAN
C-100
SCALE: 1" = 10'
LINE IS 1 INCH
AT FULL SIZE = 34x22
(IF NOT SCALE ACCORDINGLY)
No. REVISIONS BY DATE
PROJECT DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DRAWING FILE:
PROJECT No.:
SCALE:
DRAWING No.
SHEET
___ OF ___AS NOTED SEE MARGIN
Monday, February 17, 2025 9:51:12 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 C-100.dwg
DESIGN ENGINEER
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100
ORLANDO, FL 32803
PH: (407) 896-8608
ENGINEERING REGISTRY NO. 6899
LIFT STATION NO. 7 REPAIRS AND UPGRADES
SV
10" SAN SEWER
TO REMAIN
REMOVE BFP AND
WATER METER
REMOVE CONCRETE
AND REPLACE WITH SOD
REMOVE 6"
FM BEGIN
REMOVE 6" FM
END
REMOVE TOP AND CONTENTS
FROM WET PIT. CUT PIT TO
ELEVATION 3.25'. FILL
REMAINING WITH SAND AND/OR
EXCAVATABLE FLOWABLE FILL.
6" FM
TO REMAIN
REMOVE 10" SAN SEWER
REMOVE ELEC
RACK AND PANELS
TO BE REMOVED
BY OTHERS
REMOVE 1"
WATER SEVICE
REMOVE PUMPS, VALVES, FITTINGS,
ACCESSORIES AND DISCHARGE PIPING
FROM DRY PIT. CUT AND REMOVE TOP
OF PIT TO ELEVATION 3.25'. FILL
REMAINING WITH SAND AND/OR
EXCAVATABLE FLOWABLE FILL.
REMOVE AS REQ FOR
INSTALLATION OF
PROPOSED UTILITIES
(CUT AND CAP)
REMOVE AS REQ FOR
INSTALLATION OF
PROPOSED UTILITIES
(CUT AND CAP) WATER SERVICE
TO REMAIN
6" FM
TO REMAIN
CONTRACTOR SHALL USE LOOMIS
AVENUE (RESIDENTIAL STREET) TO
ACCESS CONSTRUCTION SITE.
6 19
2021-34-02
MAY 2025
NDH
JAB
EJG
MAY 2025 - BID SET
LIFT STATION 7
DEMOLITION PLAN
C-101
SCALE: 1" = 10'
LINE IS 1 INCH
AT FULL SIZE = 34x22
(IF NOT SCALE ACCORDINGLY)
No. REVISIONS BY DATE
PROJECT DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DRAWING FILE:
PROJECT No.:
SCALE:
DRAWING No.
SHEET
___ OF ___AS NOTED SEE MARGIN
Monday, February 17, 2025 9:51:12 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 C-101.dwg
DESIGN ENGINEER
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100
ORLANDO, FL 32803
PH: (407) 896-8608
ENGINEERING REGISTRY NO. 6899
LIFT STATION NO. 7 REPAIRS AND UPGRADES
NOTES:
1. CONTRACTOR TO FIELD VERIFY ALL EXISTING UTILITIES PRIOR TO ANY CONSTRUCTION
ACTIVITIES. IF ANY EXISTING UTILITIES ARE FOUND ON SITE THAT DO NOT MATCH WHAT IS
SHOWN ON THE PLANS THE ENGINEER OF RECORD AND THE CITY OF DAYTONA BEACH
SHALL BE CONTACTED IMMEDIATELY AND NO CONSTRUCTION MAY COMMENCE UNTIL
CONFLICT(S) HAVE BEEN IDENTIFIED, ACCEPTED BY ALL PARTIES INVOLVED AND
RESOLVED.
2. CONTRACTOR TO PROVIDE A DEWATERING PLAN TO THE CITY OF DAYTONA BEACH
UTILITIES DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ANY DEWATERING
ACTIVITIES ON SITE.
22' WIDE DBL
SWING GATE
ELEV. 8.41
ELEV. 8.10
ELEV. 8.34
ELEV. 9.50
MATCH EXIST GRADE
INSTALL 117 LF OF 10" C-900
PVC SAN SEWER @ 0.28%
CONST 3500 PSI 6" THICK CONC SLAB
w/ #4 REBAR @ 12"
CONST CONC DRIVEWAY
14' MIN WIDTH
INSTALL LS WATER SERVICE
(SEE LS WATER SERVICE DETAIL)
EXIST 6" PVC FM
TO REMAIN
INSTALL 1" POLY WATER SERVICE
INSTALL 67' x 35'
CHAIN LINK FENCE
INSTALL NO. 57 STONE (6" THICK)
OVER FILTER FABRIC SHALL
EXTEND 1' OUTSIDE FENCELINE
ELEV. 8.27
ELEV. 7.93
EXIST 6" PVC FM
TO REMAIN
INV. -8.87
GRAVITY WALL SECTION
NTS
2'-0"
MIN
8"
C.I.P. GRAVITY WALL
(PER FDOT INDEX 400-011
SCHEME 2)FLOW LINE SWALE
ELEV. 8.05
ELEV. 8.14
10.00
MATCH EXIST GRADE
BACK OF WALL MATCH
EXIST GRADE
MATCH EXIST GRADE
MATCH EXIST GRADE
CONNECT TO EXIST 6" PVC FM
INSTALL:
2-6" PLUG VALVE
1-6" WYE
1-6" 45° BEND ELEV. 4.13
ELEV. 9.50
MATCH EXIST GRADE
MATCH EXIST GRADE
ELEV. 8.00 ELEV. 9.00
TOP OF WALL
ELEV. 10.00
TOP OF WALL
ELEV. 10.00INSTALL ELEC PANEL RACK
PAD ELEV 10.00
(SEE ELEC DWGS)
INSTALL GENERATOR
PAD ELEV 10.00
(SEE ELEC DWGS)
INSTALL GRAVITY WALL PER INDEX
400-011, SCHEME 2.
(SEE GRAVITY WALL SECTION THIS SHEET)
MATCH EXIST GRADE
5'-0"
MAX
10.00
ELEV. 3.87
ELEV. 4.27
ELEV. 4.26
ELEV. 4.00
ELEV. 6.94
ELEV. 6.19
ELEV. 10.00
SLOPE TO MATCH EXIST GRADE(TYP)
6" PVC FM
(BELOW GRADE)
16' WIDE DBL
SWING GATE
16' WIDE DBL
SWING GATE
ELEV. 9.50
ELEV. 9.36
CONNECT TO EXIST 6" PVC FM
INSTALL:
1-6" WYE
1-6" PLUG VALVE
6" PVC FM
(BELOW GRADE)
INV. 4.00INSTALL 6" DISCHARGE PIPING.
REFER TO PS-100
(ABOVE GRADE)
INSTALL LINED 8'
DIA WET WELL
(APPROX. 26' DEEP)
LINE IS 1 INCH
AT FULL SIZE = 34x22
(IF NOT SCALE ACCORDINGLY)
No. REVISIONS BY DATE
PROJECT DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DRAWING FILE:
PROJECT No.:
SCALE:
DRAWING No.
SHEET
___ OF ___AS NOTED SEE MARGIN
Monday, February 17, 2025 9:51:12 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 C-102.dwg
DESIGN ENGINEER
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100
ORLANDO, FL 32803
PH: (407) 896-8608
ENGINEERING REGISTRY NO. 6899
LIFT STATION NO. 7 REPAIRS AND UPGRADES
THE CITY OF DAYTONA BEACH
UTILITIES DEPARTMENT
7 19
2021-34-02
MAY 2025
NDH
JAB
EJG
MAY 2025 - BID SET
LIFT STATION 7
PROPOSED SITE PLAN
C-102
SCALE: 1" = 5'
M
AT
C H
L
IN
E
ST
A
+4
1. CONTRACTOR TO FIELD VERIFY ALL EXISTING UTILITIES PRIOR TO ANY CONSTRUCTIONACTIVITIES. IF ANY EXISTING UTILITIES ARE FOUND ON SITE THAT DO NOT MATCH WHAT ISSHOWN ON THE PLANS THE ENGINEER OF RECORD AND THE CITY OF DAYTONA BEACHSHALL BE CONTACTED IMMEDIATELY AND NO CONSTRUCTION MAY COMMENCE UNTIL
CONFLICT(S) HAVE BEEN IDENTIFIED, ACCEPTED BY ALL PARTIES INVOLVED AND
RESOLVED.
2. CONTRACTOR TO PROVIDE A DEWATERING PLAN TO THE CITY OF DAYTONA BEACH
UTILITIES DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO ANY DEWATERING
ACTIVITIES ON SITE.
CONNECT PROP SEWER
TO EXISTING MH W INVERT -8.54
REBENCH MH.
INSTALL 1" POLY WATER SERVICE
INSTALL 117 LF OF 10" C-900
PVC SAN SEWER @ 0.28%
CONNECT TO EXIST WATER SERVICE
EXIST 6" PVC FM
TO REMAIN
EXIST 6" PVC FM
TO REMAIN
CUT, CAP AND PLUG S INVERT.
EXIST 10" UNK SAN SEWER
TO REMAIN
REMOVE AND REPLACE EXIST MH FRAME AND COVER.
INSTALL FIBERGLASS INSERT LINE AND COAT THE BENCH
WITH RAVEN 405. CERTIFIED RAVEN 405 INSTALLER
SHALL INSTALL THE RAVEN 405 LINER PER RAVEN'S
MANUFACTURER'S SPECIFICATIONS AND THE CITY OF
DAYTONA BEACH UTILITY STANDARDS.
LINE IS 1 INCH
AT FULL SIZE = 34x22
(IF NOT SCALE ACCORDINGLY)
No. REVISIONS BY DATE
PROJECT DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DRAWING FILE:
PROJECT No.:
SCALE:
DRAWING No.
SHEET
___ OF ___AS NOTED SEE MARGIN
Monday, February 17, 2025 9:51:12 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 C-103.dwg
DESIGN ENGINEER
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100
ORLANDO, FL 32803
PH: (407) 896-8608
ENGINEERING REGISTRY NO. 6899
LIFT STATION NO. 7 REPAIRS AND UPGRADES
THE CITY OF DAYTONA BEACH
UTILITIES DEPARTMENT
8 19
2021-34-02
MAY 2025
NDH
JAB
EJG
MAY 2025 - BID SET
LIFT STATION 7 PROPOSED
OFFSITE PLAN
C-103
SCALE: 1" = 5'
M
AT
C
H L
IN
E
ST
A
+4
1. CONTRACTOR MUST ACCOUNT FOR CONSTRUCTING A TEMPORARY ACCESS DRIVEWAY
FROM LOOMIS AVENUE TO ACCOMMODATE HEAVY EQUIPMENT AND VEHICLES TO AND
FROM CONSTRUCTION SITE.
2. INSTALL SOIL TRACKING PREVENTION DEVICES WHERE CONSTRUCTION VEHICLES WILL BE
ENTERING AND LEAVING THE CONSTRUCTION SITE.
LOOMIS AVENUE
LO
C
KH
AR
T
ST
R
EE
T
UTILIZE EXISTING MANHOLE
FOR BYPASS PURPOSES
TEMPORARY ACCESS DRIVEWAY
(APPROXIMATE LIMITS)
KOTTLE CIRCLE
6" UNK WM
BY-PASS NOTES
1. CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING ADEQUATE BY-PASS PUMPING TO MAINTAIN
WASTEWATER SERVICE TO ALL CUSTOMERS.
2. CONTRACTOR SHALL ADHERE TO ALL REQUIREMENTS AND PROVISIONS AS SPECIFIED IN SECTION 33 31
00 OF THE CONTRACT DOCUMENTS.
3. FLOW CONTROL SHALL INCLUDE ACCOMMODATION OF FLOW FROM ANY SIDE SEWER AFFECTED BY
THE WORK.
4. OPERATION OF CITY OF DAYTONA BEACH UTILITIES DEPARTMENT PUMP STATIONS THE CONTRACTOR SHALL COORDINATE ALL PUMP STATION OPERATIONS AND SHUT DOWN CONTROL WITH THE CITY OF
DAYTONA BEACH UTILITIES INSPECTOR.
5. THE CONTRACTOR SHALL PROVIDE TEMPORARY BY-PASS PUMPING AS NEEDED FOR THE PUMP
STATION AND MANHOLE TO BE REHABILITATED AND/OR REPLACED PRIOR TO THE START OF ANY WORK. BOTH THE PRIMARY AND THE BACKUP BY-PASS PUMPING SYSTEMS SHALL BE OF ADEQUATE CAPACITIES AND SIZES TO HANDLE THE FLOW AND SHALL MAINTAIN A CONTINUOUS SERVICE DURING
THE ENTIRE CONSTRUCTION PROCESS UNTIL THE NEW OR REHABILITATED PUMP STATION OR
MANHOLE HAS BEEN ACCEPTED BY THE CITY. THE BY-PASS PUMPING SYSTEMS SHALL BE APPROVED
AND ACCEPTED BY THE CITY PRIOR TO INSTALLATION.
6. THE CONTRACTOR SHALL PREPARE AND SUBMIT FOR APPROVAL BY THE CITY A COMPREHENSIVE WRITTEN PROCEDURE THAT DESCRIBES THE INTENDED CONSTRUCTION SEQUENCE FOR MAINTAINING
AND TRANSFERRING SERVICE FROM THE EXISTING PUMP STATION TO THE NEW PUMP STATION.
RECOMMENDED SEQUENCE OF WORK:
6.1. CONSTRUCT AND INSTALL NEW WET WELL AND PROPOSED 10" C-900 PVC SAN SEWER
6.2. INSTALL ABOVE GRADE TEMPORARY BYPASS HDPE PIPING ALONG THE SCHOOL FENCE LINE
(STA 12+00 TO STA 14+65)
6.3. INSTALL HDPE SUCTION PIPING AND ABOVE GRADE BYPASS PUMPS NEAR EXISTING MANHOLE
(STA 14+65)
6.4. CONNECT ABOVE GRADE PIPING AND PUMPS
6.5. PLUG THE SW 10-INCH INVERT OF EXISTING MANHOLE (STA 14+65)
6.6. TIE-IN TO EXISTING 6" FM (STA 12+00)
6.7. CONNECT EXISTING MASTER MANHOLE (STA 12+00) TO PROPOSED 10" C-900 PVC SAN SEWER
6.8. PLACE NEW WET WELL IN SERVICE
6.9. DISMANTLE EQUIPMENT AND REMOVE OLD WET WELL AS REQ'D
10" UNK SAN SEWER
10" UNK SAN SEWER
10" UNK SAN SEWER
LINE IS 1 INCH
AT FULL SIZE = 34x22
(IF NOT SCALE ACCORDINGLY)
No. REVISIONS BY DATE
PROJECT DATE:
DESIGNED BY:
DRAWN BY:
CHECKED BY:
DRAWING FILE:
PROJECT No.:
SCALE:
DRAWING No.
SHEET
___ OF ___AS NOTED SEE MARGIN
Monday, February 17, 2025 9:51:12 AM F:\CIVIL\PROJECTS\2021\2021-34 Daytona Bch Utilities Cont Prof Engineering\2021-34.02 LS 7 Replacement\5.0 Drawings\2021-34-02 LS 7 C-104.dwg
DESIGN ENGINEER
FLORIDA REGISTRATION No.
66465
ERIN J. GIBLIN, P.E.
BARNES, FERLAND AND ASSOCIATES, INC.
1230 HILLCREST ST., STE 100
ORLANDO, FL 32803
PH: (407) 896-8608
ENGINEERING REGISTRY NO. 6899
LIFT STATION NO. 7 REPAIRS AND UPGRADES
THE CITY OF DAYTONA BEACH
UTILITIES DEPARTMENT
9 19
2021-34-02
MAY 2025
NDH
JAB
EJG
MAY 2025 - BID SET
TEMPORARY ACCESS DRIVEWAY AND
BYPASS PLAN
C-104
SCALE: 1" = 20'
LIFT STATION DATA
DIMENSIONS DESIGN AS-BUILT
DIM. A
DIM. B
DIM. C
DIM. D
DIM. E
DIM. F
DIM. G
DIM. H
DIM. J
DIM. K
DIM. L
DIM. M
ELEVATION DESIGN AS-BUILT
#1 ELEV.
#2 ELEV.
#3 ELEV.
#4 ELEV.
#5 ELEV.
#6 ELEV.
#7 ELEV.
#8 ELEV.
ALL ITEMS MUST BE FILLED IN.
DIM. N
#9 ELEV.
#10 ELEV.
#11 ELEV.
#12 ELEV.
DESCRIPTION
HIGH WATER ALARM ON
LAG PUMP ON
LEAD PUMP ON
PUMPS OFF AT 1' OFF BOTTOM OF WET WELL
INFLUENT PIPE INVERT
DRIVEWAY
TOP OF SLAB (WET WELL)
TOP OF SLAB (VALVE VAULT)
TOP OF FLOOR SLAB
BOTTOM OF FLOOR SLAB
BOTTOM OF WET WELL
BOTTOM OF TREMIE PLUG
FLYGT PUMP DATA
MANUFACTURER: MODEL:
IMPELLER NO.: NOMINAL SIZE:
SPEED: DISCHARGE SIZE:
VOLTAGE: PHASE: 3
HORSEPOWER: MIN. SOLID SIZE:
IN.
IN.
IN.
RPM
Hz.
hp.
v.
OPERATING CONDITIONS SHALL BE _____ GPM, _____ FT. TDH,
MIN. SHUT OFF HEAD _____ FT.
WET WELL NOTES
DIM. O
DIM. P
DIM. Q
DIM P = DISCHARGE PIPE DIA IN WET WELL FROM PUMP
DIM O = INFLUENT PIPE DIA GOING INTO WET WELL
DIM Q = DISCHARGE PIPE DIA OUT OF VALVE VAULT
ONE OF THE PUMPS ARE REQUIRED TO HAVE THE FLYGT MIX - FLUSH
SYSTEM MODEL 4901 FLUSH VALVE INSTALLED.
STANDARD PRE-CAST SECTION
NTS
N/A
8"
N/A 1'-5" 2'-9" 4'-3" 2'-7" N/A N/A 6" N/A 8'-0"
10" 6" N/A
FLYGT NP 3127
174 6
1750 6
7.5 3 515 28
-8.87' -9.54' -10.54' -13.87' -8.87' 9.50' 10.00' N/A -14.87' -15.03' -16.03'
N/A
N/A
NTS
PUMP BASE ANCHOR PLATE
PUMP BASE
2" MIN.
4" MIN.
2" MIN.
4" MIN.
PUMP SIDE
4' -0
" M
IN
NTS
LS WATER SERVICE
1" CURB STOP
1" GALV. PIPE
IN A VALVE BOX
2" GALV. PLUG
2" GALV. TEE 2"x1" REDUCER
1" GAL. ELBOW
3/4" SPIGOT
2" X 1" REDUCER
1"X 3/4" REDUCER
PLAN
NTS
#0 ELEV. HIGH HIGH WATER ALARM ON -8.04'
BURIED 3" x 3"
CONC POST
(2' MIN DEPTH)
PVC
TOP OF FLOOR SLAB#9 ELEV.
#1 ELEV.
#11 ELEV.
#10 ELEV.
#2 ELEV. LAG PUMP ON
HIGH WATER ALARM "ON" AT INFLUENT INVERT
#4 ELEV. PUMPS OFF AT TOP OF PUMP
#3 ELEV. LEAD PUMP ON
8" MIN.
18'' (TYP.)
12''
#5 AT 6'' EACH WAY TOP & BOTTOM
DIM O
MINIMUM 2' No. 57 STONE
4" DIAMETER SLAB PENETRATION WITH 6" S.S.
RECESSED DRAIN PLATE OR ODOR SCRUBBER (AS
REQUIRED). TOP SLAB SHALL BE 1 FOOT ABOVE
THE 100 YEAR FLOOD ELEVATION INSTALL
GOOSENECK VENT PIPE.
* SUPPORT PER
MANUFACTURER
RECOMMENDATION
EW-1 AQUAPOXY EXTERIOR 10 MIL. DRY
DFT 2-COATS AT 5 MIL. EACH (RED, BLACK)
DIM M#0 ELEV. HIGH-HIGH
N
SUBMERSIBLE,
REMOVABLE PUMP
(TYP)
& CABLE RACK
316 SS FLOAT
BOTH SIDE OF
OPENING
G F
D D
E E
NTS
ADJUSTABLE VALVE SUPPORT DETAIL NTS
ARV CONNECTION SECTION
TO ASTM C-478 & WET WELL SPECIFICATIONS
PRECAST CONCRETE MANHOLE CONFORMING
ACCESS HATCH COVER W/GASKET
HEAVY DUTY H-20 RATED ALUM.
36" x 60" MIN. (SEE NOTE 6)
CONDUITS TO PANEL
3 - 2" ELECTRICAL
FOR PUMP LEADS,
BACKUP FLOATS, &
BUBBLER TUBE.
2" PVC CONDUIT
FOR FLOWS FOR
BYPASS PUMP ONLY.
STAINLESS STEEL
DO25 ARV BODY
DBL LINK SEAL
8" MIN.
PVC
GUIDE RAILS
18" X 22" (MIN.)
1" THICK STEEL PLATE
3/4" DIA. S.S. BOLTS TO BE
WELDED TO BOTTOM SIDE OF
STEEL PLATE. FOR
DIMENSIONS SEE
MANUFACTURER'S
SPECIFICATIONS
8" X 3/4" S.S. ANCHOR BOLTS
EPOXIED IN OR J BOLTS CAST
IN PLACE
ACCESS HATCH COVER W/ GASKET
36" x 60" MIN. (SEE NOTE #6)
6" of No. 57 STONE
OVER FILTER FABRIC
#6 ELEVATION
DRIVEWAY
WET WELL INTERIOR AGRU
SURE GRIP LINING SYSTEM
RAM NEK AS SPECIFIED (TYP.) PREFORMED
JOINT GASKET AND THE INSIDE WALL OF
AGRU LINER WILL BE WELDED
NON-SHRINK GROUT OPENING
AROUND INFLUENT PIPE (TYP.)
ANCHOR PER SPECS AND MANUFACTURER'S
RECOMMENDATIONS -8"x 3/4" 316 S.S. J-BOLTS CAST IN
PLACE, SEE PUMP BASE ANCHOR PLATE DETAIL
SUBMERSIBLE PUMP
(SEE SPECIFICATIONS)
#5 ELEV.
INFLUENT
INV. EL. -8.87
CONCRETE DRIVEWAY SLOPE
GRADE AWAY FROM STRUCTURE
#5 DOWELS AT 12'' BOTTOM SLAB ELEVATION
3/8" S.S. 316 CHAINS w/
S.S. CLEVIS
POWER
CABLE
2" ELECTRICAL
CONDUIT (TYP.)
DIM P 316 S.S. DISCHARGE PIPING (SCH 40)
#7 ELEVATION TOP OF WET WELL
12" LONG (MIN) FLANGE
SPOOL PIECE (DIP)
FLANGED CHECK VALVE (LEVER & WEIGHT)
6" MAX.
#5 @ 12" EACH WAY
TOP & BOTTOM
SST
PVC
8" MIN. 30"
MIN.
90° BEND
6" C-900 PVC FM
PLUMB ARV DRAIN AND SLOPE
BACK TO WET WELL (SEE NOTE 21)
(K)
MJ CONNECTION
SEAT END ON CHECK VALVE SIDE
FLANGED PLUG VALVE
AIR RELEASE VALVE
(SEE DETAIL ABOVE)
CROSS (FLANGED)
FLANGED CONNECTION
DIP FLANGED PIPE
6" THICK CONCRETE (DRIVEWAY - SEE CIVIL FOR ELEVATIONS)
"M
AX
"M
IN
" M
IN
C O
VE
R
SEE VALVE SUPPORT DETAIL
(THIS SHEET)
316 S.S. FLOAT &
CABLE RACK
BOTH SIDE OF
OPENING
VEGA RADAR UNIT
1. COVER FOR REINFORCING BARS SHALL BE 2".
2. ALL BENDS, UNLESS OTHERWISE SHOWN, SHALL BE A 90 DEGREE STANDARD HOOK AS DEFINED IN THE LATEST EDITION OF ACI 318.
3. NON-SHRINK GROUT FOR ALL OPENINGS.
4. ALL INTERNAL STAINLESS STEEL SCH. 40 IS FLANGED (RAMNEK OR APPROVED EQUAL).
5. WET WELL AGRU SURE GRIP LINER TO COVER ALL VERTICAL SURFACES, BOTTOM OF TOP SLAB AGRU OPTION 1 ONLY (ALL JOINT SHALL
BE SEALED BY MEANS OF THERMAL WELDING PERFORMED BY AGRU CERTIFIED WELDERS).
6. HATCH COVERS MUST ALLOW FOR UNRESTRICTED VERTICAL REMOVAL OF THE PUMPS AND HAVE FLUSH ALUMINUM DROP HANDLE AND
AN AUTOMATIC HOLD OPEN ARM WITH RELEASE HANDLE. (SEE DWG SHEET D-103).
7. FURNISH AND INSTALL 2 TOTALLY SUBMERSIBLE PUMPS PER PUMP DATA TABLE, FLYGT ONLY.
8. ALL VALVES ARE TO BE DEZURIK AND ALL CHECK VALVES ARE TO BE KENNEDY OR EQUAL.
9. WET WELL AND VALVE VAULT CONCRETE SHALL BE TYPE II REINFORCED CONCRETE (4,000 PSI).
10. PROVIDE SS INSECT SCREEN WITH 1/4" OPENINGS ON VENT PIPE.
11. PROVIDE HIGH LEVEL FLOAT.
12. VEGA RADAR PULS C-21 WILL BE INSTALLED IN ALL LIFT STATION. REPLACING THE TRANSDUCER IN THE WET WELL.
13. ENGINEER SHALL DESIGN SITE…