LS Drawings Bldg 111 Bldg 144.pdf
PDF 15 MB Posted
- Solicitation number
- 36C25224Q0512
About this file
This document appears to be a set of drawings related to a federal contract opportunity for fire barrier maintenance, inspection, and repair services at the Clement J. Zablocki Medical Center in Milwaukee, WI.
The key details of the federal contract opportunity are: The contractor shall provide all labor, materials, tools, management, travel, and equipment necessary to inspect and repair the rated wall assemblies located within Buildings 111 and 144 of the medical center, with an approximate combined square footage of 922,455. The work is to begin within 90 days of contract award. The solicitation is being issued by the Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 12. This is a solicitation for the required services, with no incumbent contractor identified.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25224Q0512 R COMPLETE.docx | DOCX document | |
| SOC08 111-7 SOC.pdf | ||
| FMD-002.pdf | ||
| SOC05 111-4 SOC.pdf | ||
| SOC07 111-6 SOC.pdf | ||
| SOC11 111-10 SOC.pdf | ||
| SOC02 144-1-SOC.pdf | ||
| SOC10 111-9 SOC.pdf | ||
| SOC12 111-11-SOC.pdf | ||
| SOC14 111-13-SOC.pdf | ||
| SOC09 111-8 SOC.pdf | ||
| SOC01 144-B-SOC RE.pdf | ||
| SOC04 111-3 SOC.pdf | ||
| SOC03 111-2 SOC.pdf | ||
| 00S-214.pdf | ||
| SOC02 144-PENTHOUSE-SOC.pdf | ||
| FMD-058 .pdf | ||
| SOC02 111-1 SOC.pdf | ||
| SOC06 111-5 SOC.pdf | ||
| SOC13 111-12-SOC.pdf | ||
| SOC01 144-B-SOC.pdf | ||
| SOC01 111-B SOC.pdf | ||
| SOC02 144-1-SOC NW.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 2-HOUR WALL ASSEMBLIES. PENETRATIONS ARE TO BE FILLED
ON BOTH SIDES OF THE WALL.
ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DOORS:
PENETRATIONS:
DUCTS:
WALL CONSTRUCTION:
2-HOUR FIRE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND
STAIRWELLS OF 4 OR MORE STORIES.
1-HOUR FIRE BARRIER
THIS APPLIES TO 1-HOUR RATED ENCLOSURES, HAZARDOUS ROOMS AND
STAIRWELLS 3 STORIES OR LESS.
DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1, NFPA 101 8.3.3.2.2)
2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 101 TABLE 8.3.3.2.2)*
3. VISION PANEL - MAXIMUM SIZE TESTED (NFPA 80 4.4.5 & NFPA 101 TABLE
8.3.3.2.2)
4. POSITIVE LATCHING (NFPA 80 4.3.7)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 4.3.7)
6. COORDINATING DEVICES REQUIRED ON DOORS WITH ASTRAGALS THAT
PREVENT LATCHING (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP BETWEEN DOORS (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" NON-LABELED PROTECTIVE PLATE (NFPA 80 6.4.5.3)
10. STAIRWELL DOORS SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101
7.2.1.4.2)
11. SWING IN ANY DIRECTION FOR HAZARDOUS ROOMS (NFPA 101 18/19.3.2.1
& 7.2.1.2)
12. FIRE DOOR ASSEMBLIES SHALL BE INSPECTED AND TESTED ANNUALLY
(NFPA 80 5.2.4.1)
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR WALL ASSEMBLIES. PENETRATIONS ARE TO BE FILLED
ON BOTH SIDES OF THE WALL.
STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS.
* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR LESS.
DOORS:
PENETRATIONS:
DUCTS:
WALL CONSTRUCTION: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS
OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION OF THE 2-HOUR
RATED WALL IS ALSO PART OF THE SMOKE WALL.
DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1; NFPA 101 8.3.3.2.2)
2. LABELED 1 1/2 HOUR DOOR (NFPA 101 TABLE 8.3.3.2.2)
3. VISION PANEL - MAXIMUM SIZE TESTED (NFPA 80 4.4.5 & NFPA 101 TABLE
8.3.3.2.2)
4. POSITIVE LATCHING (NFPA 80 4.3.7)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 4.3.7)
6. COORDINATING DEVICES REQUIRED ON DOORS WITH ASTRAGALS THAT
PREVENT LATCHING (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" NON-LABELED PROTECTIVE PLATE (NFPA 80 6.4.5.3)
10. SWING IN DIRECTION OF TRAVEL EGRESS (NFPA 101 7.2.4.3.8)
11. FIRE DOOR ASSEMBLIES SHALL BE INSPECTED AND TESTED ANNUALLY.
(NFPA 80 5.2.4.1)
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS
FOR PROTECTING 2-HOUR WALL ASSEMBLIES. PENETRATIONS ARE
TO BE FILLED ON BOTH SIDES OF THE WALL.
ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND
SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE ADJACENT
SMOKE COMPARTMENTS ARE PROTECTED BY QUICK RESPONSE SPRINKLERS
THROUGHOUT EACH COMPARTMENT.
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
2-HOUR FIRE/SMOKE BARRIER
DOORS:
PENETRATIONS:
DUCTS:
WALL CONSTRUCTION:
SMOKE ZONE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR
DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS OF
MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND THE
BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE
REQUIRED TO BE OF 1-HOUR FIRE-RESISTANCE RATING. (NFPA 101, 18.3.7.6) SMOKE ZONE
BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED TO BE OF
A 12 HOUR FIRE-RESISTANCE RATING (NFPA 101, 19.3.7.3)
DOORS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (18.3.7.6)
2. 20-MINUTE OR SOLID WOOD CORE, 13
4" THICK (NFPA 101 18.3.7.6)
3. VISION PANEL - MAXIMUM SIZE TESTED (NFPA 80 4.4.5 & NFPA 101 TABLE
8.3.3.2.2)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)
6. MAXIMUM 1/8" GAP BETWEEN DOORS (NFPA 80 6.3.1.7)
7. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
8. UNLIMITED IN HEIGHT PROTECTIVE PLATES PERMITTED (NFPA 101
18/19.3.7.6)
9. SWING IN DIRECTION OPPOSITE OF EACH IF NEW (NFPA 101 18.3.7.6)
10. SWING IN ANY DIRECTION IF EXISTING (NFPA 101 19.3.7.6)
11. SMOKE DOOR ASSEMBLIES SHALL BE INSPECTED AND TESTED
ANNUALLY (NFPA 80 5.2.4.1)
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR WALL ASSEMBLIES. PENETRATIONS ARE TO BE FILLED
ON BOTH SIDES OF THE WALL.
ALL DUCT PENETRATION ARE PROTECTED BY SMOKE DAMPERS. SMOKE
DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS
ARE PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH
COMPARTMENT - UNLESS THE STATE BUILDING CODES REQUIRE DAMPERS.
DOORS:
PENETRATIONS:
DUCTS:
WALL CONSTRUCTION: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
DOORS: DOORS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 19.3.6.3.15)
2. 20-MINUTE OR SOLID WOOD CORE DOOR (NFPA 101 19.3.6.3.1)
3. GLASS DOORS PERMITTED IF SPRINKLERED (NFPA 101
18.3.6.3.1, 19.3.6.3.17, & TABLE 8.3.4.2)
4. POSITIVE LATCHING EXCEPT TOILET ROOMS, SHOWER ROOMS AND SINK
CLOSETS (NFPA 101 18/19.3.6.3.5, 18/19.3.6.3.6
5. SELF-CLOSING NOT REQUIRED (NFPA 101 18/19.3.6.3.11)
6. LIMIT THE TRANSFER OF SMOKE (NFPA 101 18/19.3.6.3.1)
7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 AND 19.3.6.3.4)
8. UNLIMITED IN HEIGHT PROTECTIVE PLATES PERMITTED (NFPA 101
18/19.3.6.3.12)
9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS,
SHOWER AND SINK CLOSETS (NFPA 101 18/19.3.6.4.2)
10. SWING IN ANY DIRECTION (NFPA 101 7.2.1.4.2)
11. DOORSTOPS NOT PERMITTED (NFPA 101 18/19.3.6.3.10)
THIS APPLIES TO EXISTING SMOKE BARRIER WALLS.
ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE
DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE
ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK
RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1 HOUR ASSEMBLIES.
DOORS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 8.5 & 19.3.7.3).
2. CONSTRUCTION THAT RESISTS FIRE FOR 20 MINUTES (NFPA 101 19.3.7.6)
3. VISION PANEL - MAXIMUM SIZE TESTED (NFPA 101 19.3.7.6.2)
4. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.7.8)
6. POSITIVE LATCHING NOT REQUIRED (NFPA 101 19.3.7.8)
7. MINIMUM CLEARANCE NECESSARY FOR PROPER OPERATION (NFPA 101
8.5.4.1)
8. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4.1)
9. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 19.3.7.6.1)
10. SWING IN ANY DIRECTION OF TRAVEL (NFPA 101 19.3.7.8)
11. SMOKE DOOR ASSEMBLIES SHALL BE INSPECTED ANNUALLY (NFPA 80
5.2.4.1)
NOTE: ALL CODE REFERENCES ARE PER THE 2021 EDITION OF NFPA 101 LIFE SAFETY CODE AND THE OTHER APPLICABLE CODES.
FEDERAL FACILITIES FOLLOW 2021 LIFE SAFETY CODE.
HEALTH CARE OCCUPANCY NON-RATED CORRIDOR
CORRIDOR WALLS SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OR ROOF
DECK ABOVE AND SHALL HAVE A FIRE RESISTANCE RATING OF NOT LESS THAN 1/2 HOUR,
EXCEPT IF SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL BE PERMITTED TO
TERMINATE AT THE CEILING.
30 MINUTE SMOKE BARRIER
WALL CONSTRUCTION:
DUCTS:
PENETRATIONS:
DOORS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1; NFPA 101 8.3.3.2.2)
2. LABELED 1 1/2 HOUR DOOR (NFPA 101 TABLE 8.3.3.2.2)
3. VISION PANEL - MAXIMUM SIZE TESTED (NFPA 80 4.4.5 & NFPA 101 TABLE
8.3.3.2.2)
4. POSITIVE LATCHING (NFPA 80 4.3.7)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 4.3.7)
6. COORDINATING DEVICES REQUIRED ON DOORS WITH ASTRAGALS THAT
PREVENT LATCHING (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP BETWEEN DOORS (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" NON-LABELED PROTECTIVE PLATE (NFPA 80 6.4.5.3)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 7.2.4.3.8)
11. FIRE DOOR ASSEMBLIES SHALL BE INSPECTED AND TESTED ANNUALLY.
(NFPA 80 5.2.4.1)
DOORS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1 & 19.3.6.3.15)
2. CONSTRUCTION THAT RESISTS FIRE FOR 20 MINUTES OR SOLID WOOD
CORE (NFPA 101 18/19.3.6.3.1)
3. VISION PANEL - MAXIMUM SIZE TESTED (NFPA 101 18/19.3.2.1; 8.4)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18/19.3.6.3.5 & CMS)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 10118.3.6.3.11 & 19.3.2.1.3)
6. MAXIMUM 1/8" GAP PER MANUFACTURES RECOMMENDATION ((NEW) NFPA
101 18.3.6.3.1 /(EXISTING) 19.3.2.1.2 &8.4.3.4)
7. MAXIMUM 3/4" UNDERCUT (NFPA 101 18.3.2.1; 19.3.2.1.2)
8. UNLIMITED HEIGHT IN NEW & EXISTING MAXIMUM 48" PROTECTIVE PLATE
IN RATED ROOMS (NFPA 101 19.3.2.1.4)
9. SWING IN ANY DIRECTION (NFPA 101 7.2.1.4.2)
DOORS:
DUCTS:
EXISTING HAZARDOUS ROOMS:
NO REQUIREMENTS FOR PENETRATIONS ABOVE THE CEILING IF
SPRINKLERED. IF THE SPACE IS NON-SPRINKLERED, THEN THE WALL NEEDS
TO GO TO THE DECK ABOVE.
STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS OR SMOKE DAMPERS.
WALLS ONLY NEED TO GO UP TO THE DROP CEILING IF SPRINKLERED OR UP
TO THE DECK ABOVE IF THERE IS NO CEILING IN THE SPRINKLERED ROOM.
HAZARDOUS ROOMS:WALL CONSTRUCTION:
NON-RATED SMOKE PARTITION
WALL CONSTRUCTION:
DUCTS:
PENETRATIONS:
DOORS:
WALL EXTENDS FROM FLOOR TO CEILING OR DECK ABOVE.
NO MINIMUM REQUIREMENTS.
NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A
SUSPENDED CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR
DECK SEALED WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.
NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC
CLOSING.
FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER ZONE.
BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY THE FIRE
DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99 AND PRIVATE MODE AUDIBLE
REQUIREMENTS OF SECTION 18.4.5 OF NFPA 72.
(COLOR #230)
(COLOR #5)
(COLOR #3)(COLOR #4)
(COLOR #1)(COLOR #5)
(COLOR #30)
(COLOR #30)
SUITE DESIGNATION
AREA OPEN TO CORRIDOR - WITH SMOKE DETECTION
EXIT STAIR OR PASSAGEWAY
SMOKE RESISTIVE HAZARDOUS AREA
1 HOUR FIRE BARRIER ENCLOSURE
FIRE ALARM/SPRINKLER ZONES
AREA OPEN TO CORRIDOR WITH 24/7 SUPERVISION
- NO SMOKE DETECTION REQUIRED
(Color #2)
(Color #40)
(Color #230)
(Color #4)
(Color #3)
(Color #2)
SYMBOLS LIST
FIRE EXTINGUISHER
EXIT SIGN
F
FAAP
FACP
SPRINKLER SYSTEM RISER
EMERGENCY LIGHT
FIRE ALARM PULL STATION
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
* 2-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 4 STORIES OR MORE.
DESCRIPTION PAGE
WALL TYPES
CONSULTANTS KC, LLC
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816)931-3377
FP&C
PENETRATIONS
FIRE/SMOKE BARRIER PEN-X
AutoCAD SHX Text
DESCRIPTION PAGE
AutoCAD SHX Text Sht. 1 Of 1
AutoCAD SHX Text Date
AutoCAD SHX Text Revisions
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text AutoCAD File Name
AutoCAD SHX Text Building No.
AutoCAD SHX Text Client Project No.
AutoCAD SHX Text Project Title
AutoCAD SHX Text Drawn By
AutoCAD SHX Text Location
AutoCAD SHX Text Designed By
AutoCAD SHX Text
DJB
AutoCAD SHX Text
BWC
AutoCAD SHX Text Checked By
AutoCAD SHX Text Scale:
AutoCAD SHX Text Date
AutoCAD SHX Text
DJB
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
MILWAUKEE, WISCONSIN
AutoCAD SHX Text
CLEMENT J. ZABLOCKI VAMC
AutoCAD SHX Text
CLEMENT J. ZABLOCKI
AutoCAD SHX Text
VAMC
AutoCAD SHX Text Milwaukee, WI 53295
AutoCAD SHX Text 5000 W. National Ave.
AutoCAD SHX Text 06/12/23
AutoCAD SHX Text
X1 DESCRIPTIONPAGE
AutoCAD SHX Text 23104.00
AutoCAD SHX Text FP&C Project No.
AutoCAD SHX Text Client Review Set
AutoCAD SHX Text 07/15/2023
AutoCAD SHX Text Final Submittal
AutoCAD SHX Text 08/15/2023
1. THE ORIGINAL BUILDING WAS DESIGNED TO THE 1965 EDITION OF NFPA 101, LIFE SAFETY CODE.
2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW THE LATEST
EDITIONS OF NATIONALLY RECOGNIZED FIRE AND LIFE SAFETY CODES. THE VA HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE
SPECIFICALLY ADDRESSED IN THE 2018 EDITION OF NFPA 101, LIFE SAFETY CODE.
3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT’S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR
EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE CODES AND STANDARDS.
4. OTHER NFPA CODES AND STANDARDS:
4.1. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2022 EDITION
4.2. NFPA 13 - SPRINKLER SYSTEMS, 2022 EDITION
4.3. NFPA 14 - STANDPIPE SYSTEMS, 2019 EDITION
4.4. NFPA 20 - FIRE PUMPS, 2022 EDITION
4.5. NFPA 25 - WATER-BASED FIRE PROTECTION SYSTEMS 2023 EDITION
4.6. NFPA 70 - NATIONAL ELECTRIC CODE, 2023 EDITION
4.7. NFPA 72 - NATIONAL FIRE ALARM CODE, 2022 EDITION
4.8. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2020 EDITION
4.9. NFPA 80 - FIRE DOORS, 2022 EDITION
4.10. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2021 EDITION
4.11. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2021 EDITION
4.12. NFPA 99 - HEALTH CARE FACILITIES CODE, 2021 EDITION
4.13. NFPA 105 - SMOKE DOORS, 2022 EDITION
4.14. NFPA 110 - EMERGENCY POWER SYSTEMS, 2022 EDITION
4.15. NFPA 241 - CONSTRUCTION AND DEMOLITION, 2022 EDITION
APPLICABLE CODES AND STANDARDS
1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR AISLES AND TO DEFINE THE END OF PUBLIC EXIT CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE SUITE MAY DIRECT OCCUPANTS INTO A SUITE
TO REACH AN EXIT.
2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.
3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:
3.1. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2.B)
3.2. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)
3.3. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION, OR WITH QUICK
RESPONSE SPRINKLERS - 7,500 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.B)
3.4. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE
DETECTION - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.C)
4. PATIENT CARE NON - SLEEPING SUITES:
4.1. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101-19.2.5.7.3.1.B)
4.2. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 -19.2.5.7.3.2)
4.3. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION, OR WITH QUICK
RESPONSE SPRINKLERS -12,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.2.A)
4.4. MULTI EXIT SUITE WITH QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION - 15,000 SQ. FT. (NFPA
101 - 19.2.5.7.3.2.B)
5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE REQUIREMENTS AS LISTED
IN TABLE A.7.6 OF NFPA 101.
6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL DISTANCE
REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
SUITES
1. EXITS (STAIRWAYS, HORIZONTAL EXITS AND DIRECT EXTERIOR EXIT DOORS), OTHER THAN EXTERIOR EXIT DOORS THAT ARE OBVIOUSLY AND CLEARLY IDENTIFIABLE AS EXITS. (GLASS DOORS, VISION PANELS OR ADJACENT WINDOWS) SHALL
BE MARKED WITH EXIT SIGNAGE. (NFPA 101 - 7.10.1.2.1)
2. DIRECTIONAL SIGNS REQUIRED WHERE DIRECTION OF TRAVEL IS NOT APPARENT IN AN EXIT ACCESS CORRIDOR. (NFPA 101 - 7.10.2.1)
3. DIRECTIONAL SIGNAGE (EXIT PLACARDS) REQUIRED WITHIN HORIZONTAL COMPONENTS OF EXIT STAIR ENCLOSURES
WHERE EGRESS PATH IS NOT OBVIOUS (NFPA 101 - 7.10.2.2 AND 7.10.1.2.2)
4. MAXIMUM VIEWING DISTANCE TO AN EXIT SIGN IN AN EXIT ACCESS CORRIDOR IS 100 FT. (NFPA 101 - 7.10.1.5.2)
5. EXIT SIGNS SHALL BE INSPECTED MONTHLY. (NFPA 101 - 7.10.9)
6. DIRECTIONAL SIGNAGE (EXIT PLACARDS OR EXIT SIGNS) WITH OR WITHOUT DIRECTIONAL ARROWS SHOULD BE
PROVIDED IN SUITES USED BY THE GENERAL PUBLIC (LESS THAN 50 TOTAL OCCUPANTS) TO DIRECT THE GENERAL
PUBLIC BACK TO THE WAITING AREA. (NFPA 101 - 7.10.2.1)
7. ROOMS OR SUITES OF ROOMS USED FOR 50 OCCUPANTS OR MORE SHALL BE PROVIDED WITH EXIT SIGNAGE. (NFPA 101
- 13.2.10.1 AND 3.3.198.2)
EXIT SIGN REQUIREMENTS
THE VA HAS ELECTIVE ACCREDITATION WITH THE JOINT COMMISSION (TJC) FOR HEALTH CARE FACILITIES. SEE THE MEMORANDUM OF UNDERSTANDING (EFFECTIVE SEPTEMBER 4, 2017) BETWEEN THE VA AND TJC FOR IMPLEMENTATION OF
TJC ENVIRONMENT OF CARE (EC) AND LIFE SAFETY (LS) STANDARDS.
THE VA HAS ELECTIVE ACCREDITATION WITH THE LONG-TERM CARE INSTITUTE, INC. (LTCI) FOR COMMUNITY LIVING CENTERS (CLC). SEE THE CLARIFICATION MEMORANDUM BETWEEN THE VA AND THE LTCI FOR IMPLEMENTATION OF LIFE SAFETY
REQUIREMENTS.
THE FOLLOWING NATIONWIDE VA EQUIVALENCIES HAVE BEEN REVIEWED AND APPROVED BY THE JOINT COMMISSION AND
APPLY TO ALL BUILDINGS:
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON FIRE RATED DOORS
2. BUSINESS OCCUPANCY DEAD END CORRIDORS PERMITTED TO EXCEED 50 FEET
3. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR DOORS IN A DORMITORY OCCUPANCY
EQUIVALENCIES
1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO NFPA 13 AND NFPA 14.
2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS (NFPA 13 - 3.3.4.16).
3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 225 SQ. FT. (NFPA 13 - TABLE
19.2.3.1.1).
4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR SHOPS AND STORAGE ROOMS UNDER 250
SQ. FT. AT A 0.15 GPM/1500 SQ. FT. DENSITY. MAXIMUM PROTECTION AREA OF 150 SQ. FT. (NFPA 13 - TABLE 19.2.3.1.1).
5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ. FT. DENSITY.
6. MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS SHALL NOT EXCEED 7'-6" (NFPA 13 - 10.2.5.2.1). MAXIMUM DISTANCE FROM SPRINKLERS TO WALLS FOR STANDARD SPRAY SPRINKLERS IN SMALL ROOMS (800 SQ. FT.
MAXIMUM) SHALL NOT EXCEED 9' FROM ANY SINGLE WALL (NFPA 13 -10.2.5.2.3).
7. SPRINKLERS SHALL BE INSTALLED UNDER FIXED OBSTRUCTIONS (I.E. DUCTWORK) OVER 4' WIDE (NFPA 13-12.1.10.3.2). THE WIDTH OF DUCT INSULATION NOT A FACTOR FOR SPRINKLERS INSTALLED PRIOR TO THE CURRENT EDITION ON NFPA 13.
SPRINKLERS NOT REQUIRED UNDER NON COMBUSTIBLE OBSTRUCTIONS OVER 4' WIDE WHERE THE BOTTOM OF THE OBSTRUCTION IS A MAXIMUM 24" ABOVE THE FLOOR (NFPA 13 - 9.5.5.3.1).
8. SPRINKLERS SHALL BE INSTALLED A MAXIMUM 12" BELOW A CEILING OR FLOOR/ROOF DECK (NFPA 13 - 10.2.6.1.1.1) OR A MAXIMUM 22" BELOW A FLOOR/ROOF DECK WITH STRUCTURAL MEMBER OBSTRUCTIONS (NFPA 13-10.2.6.1.2).
9. SHELVING ON A WALL OR SHELVING AGAINST A WALL INCLUDING STORAGE THEREON SHALL BE PERMITTED TO EXTEND WITHIN THE 18" SPRINKLERS CLEARANCE BELOW CEILING SPRINKLER DEFLECTORS (NFPA - 13 9.5.5.2).
10. WHERE THE 18" CLEARANCE BETWEEN SPRINKLERS AND SHELVING STORAGE CANNOT BE MAINTAINED, SPRINKLERS SHALL BE INSTALLED IN EVERY AISLE PER NFPA 13 - 9.5.5.2.
11. CEILING MOUNTED OBSTRUCTIONS (I.E. PATIENT LIFT TRACKS) WITHIN THE 8" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.1.2 AND FIGURE 10.2.7.1.2(a).
12. FLOOR MOUNTED OBSTRUCTIONS (I.E. ROOM DIVIDERS OR SHELVING) WITHIN THE 18" SPRINKLER DISCHARGE CLEARANCE ARE PERMITTED PER NFPA 13 - TABLE 10.2.7.2.2 AND FIGURE 10.2.7.2.2.
FIRE SPRINKLER SYSTEM
1. THE FIRE ALARM SYSTEM WAS DESIGNED TO 2019 EDITION OF NFPA 72, NATIONAL FIRE ALARM CODE.
2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA 101-2018 EDITION.
3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN CORRIDORS AND LARGER ROOMS OR SUITES PER SECTION 18.4.4.1 OF NFPA 72 - 2019 EDITION.
4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT REDUCED QUANTITY AND SPACING PER SECTION 18.6 OF THE NFPA 72 - 2019 EDITION.
5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN ACCORDANCE WITH SECTION 18.5.4.3.2(3) OF NFPA 72 - 2019 EDITION.
6. TYPICAL SMOKE DETECTORS HAVE A 21 FT. RADIUS OF COVERAGE AREA (NFPA 72 -17.7.3.2.3.1) SMOKE DETECTORS THAT ARE CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND LOCATED ON BOTH SIDES OF SMOKE/FIRE DOORS MAY BE SPACED AT
MAXIMUM 21' RADIUS FOR DOOR RELEASE SERVICE (NFPA 72 - 17.7.5.6.1)
7. SMOKE DETECTORS NOT CONNECTED TO THE BUILDING FIRE ALARM SYSTEM AND USED EXCLUSIVELY FOR SMOKE/FIRE DOOR RELEASE SHALL BE LOCATED AND SPACED PER NFPA 2- 17.7.5.6.
8. CEILINGS WITH BEAM DEPTHS OF LESS THAN 10% OF CEILING HEIGHT SHALL BE CONSIDERED A SMOOTH CEILING FOR SMOKE DETECTOR COVERAGE. CEILINGS WITH BEAM DEPTHS GREATER THAN 10% OF CEILING HEIGHT SHALL HAVE REDUCED SMOKE
DETECTOR SPACING COVERAGE (NFPA 72 -17.7.3.2.4.2).
9. SMOKE DETECTORS SHALL BE LOCATED ON THE CEILINGS THE BOTTOM OF BEAMS OR MAXIMUM 12" DOWN FROM THE CEILING TO TOP OF THE DETECTOR (NFPA 72-17.7.3.2.1).
10. SMOKE DETECTORS SHALL NOT BE LOCATED DIRECTLY IN THE AIR STREAM OF SUPPLY AIR REGISTERS (NFPA 72- 17.7.6.3.2).
FIRE ALARM SYSTEM
OCCUPANCY TABLE
BUILDING FLOOR HEALTH CARE
AMBULATORY
HEALTH CARE
BUSINESS INDUSTRIAL DORMITORY TOTAL
111 13 4,380 4,380
111 12 9,650 9,650
111 11 8,982 8,982
111 10 50,943 50,943
111 9 51,630 51,630
111 8 53,222 53,222
111 7 53,222 53,222
111 6 57,880 57,880
111 5 61,140 61,140
111 4 61,140 61,140
111 3 61,140 61,140
111 2 105,503 105,503
111 1 141,528 141,528
111 BASEMENT 137,574 137,574
144 PENTHOUSE 7,013 7,013
144 1 26,417 26,417
144 BASEMENT 31,091 31,091
TOTALS 509,163 194,750 188,517 30,025 0 922,455
DESCRIPTION PAGE
CODE SUMMARY
CONSULTANTS KC, LLC
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816)931-3377
FP&C
FIRE/LIFE SAFETY LS-X2
AutoCAD SHX Text
DESCRIPTION PAGE
AutoCAD SHX Text Sht. 1 Of 1
AutoCAD SHX Text Date
AutoCAD SHX Text Revisions
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text AutoCAD File Name
AutoCAD SHX Text Building No.
AutoCAD SHX Text Client Project No.
AutoCAD SHX Text Project Title
AutoCAD SHX Text Drawn By
AutoCAD SHX Text Location
AutoCAD SHX Text Designed By
AutoCAD SHX Text
JMZ
AutoCAD SHX Text
BWC
AutoCAD SHX Text Checked By
AutoCAD SHX Text Scale:
AutoCAD SHX Text Date
AutoCAD SHX Text
DJB
AutoCAD SHX Text Drawing No.
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
MILWAUKEE, WISCONSIN
AutoCAD SHX Text 23104.00
AutoCAD SHX Text
CLEMENT J. ZABLOCKI VAMC
AutoCAD SHX Text
CLEMENT J. ZABLOCKI
AutoCAD SHX Text
VAMC
AutoCAD SHX Text Milwaukee, WI 53295
AutoCAD SHX Text 5000 W. National Ave.
AutoCAD SHX Text 06/12/23
AutoCAD SHX Text
X2 CODE SUMMARY
AutoCAD SHX Text FP&C Project No.
AutoCAD SHX Text Client Review Set
AutoCAD SHX Text 07/15/2023
AutoCAD SHX Text Final Submittal
AutoCAD SHX Text 08/15/2023
File details come from the government source that posted it. Updated .