Lock Specs.pdf

PDF 66 KB Posted

Attached to
Southern Steel Locks
Solicitation number
B2728038
Issued by
Pennsylvania

About this file

This is a specifications document for institutional mortise electric locks provided by Southern Steel Company, applicable to a micro purchase contract opportunity with the City of Pennsylvania. The document details the 10600 series institutional mortise lock designed for minimum and medium security areas where remote electric or local manual control is required. The specifications cover multiple lock functions (models 10601 through 10609) with variations in lever operation, key access points, and locking mechanisms. Each model is available in two primary configurations: a fail-secure version (E suffix) where the lever unlocks when power is applied, and a fail-safe version (EP suffix) where the lever locks when power is applied. All locks feature deadlock actuators and are mounted for swinging doors, with a 204E power transfer hinge required for operation.

The contract is structured as a firm limit purchase to be awarded as a whole or by line item, whichever serves the City's best interest, to the lowest responsive and responsible bidder. Sellers must quote all items to be eligible for award. The document emphasizes that delivery or service provision should not commence until official notification from the department. Contact information for additional details is provided as 210-533-1231 in San Antonio, Texas. The specifications note that these locks are not intended for cell applications and recommend the use of door position switches and door closure mechanisms alongside the electric locking system.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOR MORE INFORMATION, PLEASE CALL 210-533-1231Revised 3/09

APPLICATION:

Designed for minimum and medium security areas where remote electric or local manual control of lever is desired. Door position switch and door closure are recommended. 204E power transfer hinge is required.

FUNCTION:

10600E FAIL SECURE – Lever unlocks when power is applied.

10600EP FAIL SAFE – Lever locks when power is applied.

A variety of functions are available to meet job requirements. See function chart.

THIS LOCK IS NOT INTENDED

FOR CELL APPLICATION.

10600

INSTITUTIONAL

MORTISE LOCK

E L E C T R I C L O C K S

DOOR MOUNTED FOR

SWINGING DOORS

Minimum and medium security.

B17

UL

P.O. BOX 2021 • SAN ANTONIO, TX • 78297 • 210-533-1231 • FAX: 210-533-2211Revised 3/09

10600 INSTITUTIONAL

MORTISE LOCK

E L E C T R I C L O C K S

FUNCTIONS

S O U T H E R N

S T E E L

C O M P A N Y

S O

U

T H

E R

N

S T E E L

C

O

M

P A N

Y

10602 Lockset

• Latchbolt operated by lever either side, except when both are locked out.

• Key inside operates latchbolt when both levers are locked out.

• Deadlock actuator.

• 10602E: Both levers are locked, except when power is applied.

• 10602EP: Both levers are unlocked, except when power is applied.

S O U T H E R N

S T E E L

C O M P A N Y

10601 Lockset

• Latchbolt operated by lever either side, except when both are locked out.

• Key outside operates latchbolt when both levers are locked out.

• Deadlock actuator.

• 10601E: Both levers are locked, except when power is applied.

• 10601EP: Both levers are unlocked, except when power is applied.

S O

U

T H

E R

N

S T E E L

C

O

M

P A N

Y

10604 Lockset

• Latchbolt operated by lever either side, except when inside lever is locked out.

• Key inside operates latchbolt when inside lever is locked out.

• Lever outside always active.

• Deadlock actuator.

• 10604E: Inside lever is locked, except when power is applied.

• 10604EP: Inside lever is unlocked, except when power is applied.

10603 Lockset

• Latchbolt operated by lever both sides, except when outside lever is locked out.

• Key outside operates latchbolt when outside lever is locked out.

• Lever inside always active.

• Deadlock actuator.

• 10603E: Outside lever is locked, except when power is applied.

• 10603EP: Outside lever is unlocked, except when power is applied.

S O U T H E R N

S T E E L

C O M P A N Y

S O

U

T H

E R

N

S T E E L

C

O

M

P A N

Y

10605 Lockset

• Latchbolt operated by lever both sides, except when locked out.

• Key both sides operates latchbolt when both levers are locked out.

• Deadlock actuator.

• 10605E: Both levers are locked, except when power is applied.

• 10605EP: Both levers are unlocked, except when power is applied.

S O U T H E R N

S T E E L

C O M P A N Y

10606 Lockset

• Latchbolt operated by lever inside, except when locked out.

• Key outside operates latchbolt.

• Lever outside always rigid.

• Dead lock actuator.

• 10606E: Inside lever is locked, except when power is applied.

• 10606EP: Inside lever is unlocked, except when power is applied.

B18

FOR MORE INFORMATION, PLEASE CALL 210-533-1231Revised 3/09

10600 INSTITUTIONAL

MORTISE LOCK

E L E C T R I C L O C K S

FUNCTIONS

S O U T H E R N

S T E E L

C O M P A N Y

S O

U

T H

E R

N

S T E E L

C

O

M

P A N

Y

10608 Lockset

• Latchbolt operated by lever outside, except when locked out.

• Key both sides operates latchbolt.

• Lever inside always rigid.

• Deadlock actuator.

• 10608E: Outside lever is locked, except when power is applied.

• 10608EP: Outside lever is unlocked, except when power is applied.

S O

U

T H

E R

N

S T E E L

C

O

M

P A N

Y

10609 Lockset

• Latchbolt operated by lever outside, except when locked out.

• Key inside operates latchbolt.

• Lever inside always rigid.

• Deadlock actuator.

• 10609E: Outside lever is locked, except when power is applied.

• 10609EP: Outside lever is unlocked, except when power is applied.

S O U T H E R N

S T E E L

C O M P A N Y

S O

U

T H

E R

N

S T E E L

C

O

M

P A N

Y

10607 Lockset

• Latchbolt operated by inside lever, except when locked out.

• Key both sides operates latchbolt.

• Lever outside always rigid.

• Deadlock actuator.

• 10607E: Inside lever is locked, except when power is applied.

• 10607EP: Inside lever is unlocked, except when power is applied.

B19