The file's text, extracted by GovTribe without its formatting.
illinois.gov/iema ready.illinois.gov
The Illinois Emergency Management Agency (IEMA) intends to enter into a one-year contract (July 1, 2018 – June 30, 2019) with a vendor to provide liquid nitrogen, Ultra High Purity P-10 gas, Ultra High Purity Nitrogen gas, and other gases along with tank rental and removal for the following facilities:
IEMA Bureau of Radiation Safety Radiochemistry Laboratory 1301 Knotts St.
Springfield, IL 62703-5326
Braidwood Generating Station 35100 S. Route 53 Braceville, IL 60407-9512 Byron Power Plant 4450 N. German Church Rd.
Byron, IL 61010-9794
Clinton Power Plant 8401 Power Road Clinton, IL 61727-9182 Dresden Power Plant 6500 N Dresden Road Morris, IL 60450-9736 LaSalle Power Plant 2601 N. 21st Road Marseilles, IL 61341-9757
Quad Cities Power Plant 22710 – 206th Avenue North Cordova, IL 61242-9470
· Vendor will deliver one (1) Dewar of liquid to each of the six (6) Power Plants listed above on a weekly delivery schedule, unless informed by the Agency otherwise. This schedule should be in conjunction with the Exelon delivery and will include removal of one tank upon delivery of a tank.
· Vendor will provide delivery within 48 hours of notice for the IEMA sections located at Knotts St. in Springfield, IL.
· Dry Nitrogen will be delivered on as as-needed basis and will be treated as a “Special Order.”
· “Special Orders” will be made to the Vendor via telephone and delivery will be coordinated between IEMA and the Vendor. All “Special Orders” for power plants will be made within 48 hours of request unless other delivery arrangements have been mutually agreed upon.
· Vendor will comply with all Exelon site access policies.
· Upon execution of the contract, Vendor shall conduct an inventory of all tanks for each of the Power Plants, which should be sent to Celeste Hawkins at celeste.hawkins@illinois.gov
Storage and Pick-Up Summary for Each Location:
· Braidwood – Vendor delivers the tanks outside of the Gaseous Effluent Monitoring System (GEMS) building to the left of the North-East doorway. The empties are placed in the same location for pickup.
· Byron – Vendor deliveries will be inside the Protected Area (PA), inside the GEMS building.
· Clinton – All tanks for Clinton are dropped off at the Plant’s receiving building outside of the protected area, also known as “Stores.” Once the tank leaves the vendor’s hands, it goes directly to the Plant’s staff at “Stores” and the Plant is the responsible for getting any IEMA tanks to and from our building inside the protected area from the “Stores.” All empty tanks are left in our building and placed in the same location for pickup. Exelon swaps the old for new and returns the empty tanks back to the “Stores” for vendor to pick up.
· Dresden – Vendor delivers the tanks outside of the GEMS building to the left of the North-West doorway. The empties are placed in the same location for pickup.
· LaSalle – Vendor deliveries will be inside the PA to the GEMS building.
· Quad Cities – Vendor deliveries are made directly to the warehouse outside the PA. Full bottles are then brought into the PA by the Plant personnel and empties are removed from the GEMS building when the full bottle is delivered. Again, this is by Plant personnel; vendor only visits the outside warehouse. The empties are placed in the same location for pickup.
· Radiochemistry Lab, Knotts Street, Springfield – Vendor deliveries and pickups will be inside the building in locations communicated to vendor.
Please complete the pricing tables and contact information and submit to andrew.wampler1@illinois.gov or fax to (217) 785-9962.
Pricing Table A – Nitrogen and Other Gases Product (Column A) Size (Column B) Unit (Column C) Pricing for FY19 7/1/18 – 6/30/19 (Column D)
| NITROGEN IND LIQ |
| 160LT 22PSI |
| Per Cylinder |
| NITROGEN IND LIQ |
| 160LT 230PSI |
| Per Cylinder |
| NITROGEN IND LIQ |
| 160LT 230PSI C/O |
| Per Cylinder |
| NITROGEN IND LIQ |
| 230LT cylinder with wheels 22PSI delivery |
| Per Cylinder |
| NITROGEN IND LIQ |
| 180 LT 22PSI |
| Per Cylinder |
| NITROGEN IND LIQ |
| 240 LT 22PSI |
| Per Cylinder |
| NITROGEN IND LIQ |
| 240LT 22PSI C/O |
| Per Cylinder |
| NITROGEN IND LIQ |
| 240LT 230PSI |
| Per Cylinder |
| NITROGEN INDUSTRIAL |
| 300 CGA 580 |
| Per Cylinder |
| NITROGEN INDUSTRIAL |
| 200 CGA 580 |
| Per Cylinder |
| Ultra High Purity P-10 (10% Methane Balance Argon) |
| ~300 SCF (T-Tank) |
| Per Cylinder |
| Ultra High Purity Nitrogen Gas |
| ~250 SCF (K-Tank) |
| Per Cylinder |
| Oxygen, R, 20 CF |
| 20 CF |
| Per Cylinder |
| Oxygen, K, 249 CF |
| 249 CF |
| Per Cylinder |
| A-1025 Helium, T, 278 CF |
| 278 CF |
| Per Cylinder |
| Argon, T, 336 CF |
| 336 CF |
| Per Cylinder |
| 25% CO2, 75% AR.T, 381 CF |
| 381 CF |
| Per Cylinder |
| Acetylene, MC, 10 CF |
| 10 CF |
| Per Cylinder |
| Acetylene, WS, 130 CF |
| 130 CF |
| Per Cylinder |
| N2, LIQ, GP-45, 3640 CF |
| 3640 CF |
| Per Cylinder |
| Nitrogen, Liquid, DC, 5024 CF |
| 5024 CF |
| Per Cylinder |
| P-10, T, 10% Meth. In ARG, 300 CF |
| 300 CF |
| Per Cylinder |
| Oxygen, UHP, SZ: 049 (337 CF) |
| 337 CF |
| Per Cylinder |
Pricing Table B – Tank Rental Rental (Column A) Size (Column B) Unit (Column C) Pricing for FY19 7/1/18 – 6/30/19 (Column D)
| NITROGEN IND LIQ |
| 160LT 22PSI |
| Per Day |
| NITROGEN IND LIQ |
| 160LT 230PSI |
| Per Day |
| NITROGEN IND LIQ |
| 160LT 230PSI C/O |
| Per Day |
| NITROGEN IND LIQ |
| 230LT 22PSI |
| Per Day |
| NITROGEN IND LIQ |
| 180 LT 22PSI |
| Per Day |
| NITROGEN IND LIQ |
| 240 LT 22PSI |
| Per Day |
| NITROGEN IND LIQ |
| 240LT 22PSI C/O |
| Per Day |
| NITROGEN IND LIQ |
| 240LT 230PSI |
| Per Day |
| NITROGEN INDUSTRIAL |
| 300 CGA 580 |
| Per Day |
| NITROGEN INDUSTRIAL |
| 200 CGA 580 |
| Per Day |
| Ultra High Purity P-10 (10% Methane Balance Argon) |
| ~300 SCF (T-Tank) |
| Per Day |
| Ultra High Purity Nitrogen Gas |
| ~250 SCF (K-Tank) |
| Per Day |
| Oxygen, R, 20 CF |
| 20 CF |
| Per Day |
| Oxygen, K, 249 CF |
| 249 CF |
| Per Day |
| A-1025 Helium, T, 278 CF |
| 278 CF |
| Per Day |
| Argon, T, 336 CF |
| 336 CF |
| Per Day |
| 25% CO2, 75% AR.T, 381 CF |
| 381 CF |
| Per Day |
| Acetylene, MC, 10 CF |
| 10 CF |
| Per Day |
| Acetylene, WS, 130 CF |
| 130 CF |
| Per Day |
| N2, LIQ, GP-45, 3640 CF |
| 3640 CF |
| Per Day |
| Nitrogen, Liquid, DC, 5024 CF |
| 5024 CF |
| Per Day |
| P-10, T, 10% Meth. In ARG, 300 CF |
| 300 CF |
| Per Day |
| Oxygen, UHP, SZ: 049 (337 CF) |
| 337 CF |
| Per Day |
Pricing Table C – Fees Fee (Column A) Unit (Column B) Pricing for FY19 7/1/18 – 6/30/19 (Column C)
| Delivery Fee (Springfield) |
| Per Delivery |
| Delivery Fee (Braidwood) |
| Per Delivery |
| Delivery Fee (Byron) |
| Per Delivery |
| Delivery Fee (Clinton) |
| Per Delivery |
| Delivery Fee (Dresden) |
| Per Delivery |
| Delivery Fee (LaSalle) |
| Per Delivery |
| Delivery Fee (Quad Cities) |
| Per Delivery |
| Hazardous Material Fee |
| Per Delivery |
CONTACT INFORMATION
Company Name
Company Address
City / State / Zip
Company Contact
Phone
Email Address
Date:
Notes to Vendor:
· All quoted prices must be valid for 90 days from date of submission. All prices must include shipping and handling charges. No price increases will be accepted. In the event of a price decrease, the agency is guaranteed to receive the lowest price.
· The State reserves the right to reject all offers; to reject individual offers for failure to meet any requirement; to award by item, part or portion of an item, group of items, or total; and to waive minor defects.
· Vendor must agree to partial ship equipment in case of a delay on total order. Vendor may attach a separate page describing his/her proposal for equipment or services.
· All products will be new and carry a minimum one-year warranty and/or support from date of delivery.
· Award will be based on the sum total for all products.
· If this form is not filled out in its entirety, the quote/offer may be disqualified.
· Vendor shall not bill for any taxes unless accompanied by proof the State is subject to the tax. If necessary, Vendor may request the applicable agency’s Illinois tax exemption number and federal tax exemption information.
19-588IEMA-RADSA-R-10866
image1.jpeg