Lewis_County_Rainier_North_Building_TI_-_Bid_Set.pdf

PDF 10 MB Posted

Attached to
IT building Tenant improvement
Solicitation number
31-2106b
Issued by
Kittitas County, Washington

About this file

Summary: Bid Set for Lewis County Rainier North Building Tenant Improvement

This is a comprehensive architectural and engineering bid set for the Lewis County Facilities Department's tenant improvement project at the Rainier North Building, located at 185 NW Chehalis Avenue, Chehalis, Washington 98532. The project involves the interior renovation of approximately 4,740 square feet to establish the County's Information Technology Department offices, including new construction of offices, meeting rooms, help desk and reception areas, break room, storage, restrooms, server room, and electrical room. The design is coordinated among KMB Architects (prime architect), Hargis (electrical), Hultz BHU (mechanical), and WSP (structural). The bid set includes detailed architectural drawings covering floor plans, reflected ceiling plans, interior elevations, wall sections, door and window details, casework details, and finish schedules; structural drawings with floor and roof plans and details; mechanical drawings with HVAC floor plan, equipment schedules, and VRF system schematic; and electrical drawings with lighting plans, power plans, and control systems. The project is designed to comply with the 2021 International Building Code, 2021 International Mechanical Code, 2023 National Electrical Code, Washington State Energy Code, and local City of Chehalis amendments. Key design parameters include wind speed of 110 mph (Vult), seismic design category D, 25 psf snow load, and construction type III-B for business occupancy.

The bid set specifies major scope items including interior metal stud framing with 5/8-inch Type X gypsum board, hollow metal doors and frames with hardware, acoustic ceiling tiles and gypsum board ceilings at 9-foot height, resilient flooring and carpet finishes with rubber base, ceramic tile in restrooms, solid surface countertops with casework, and paint finishes. Mechanical work includes installation of a Variable Refrigerant Flow (VRF) system with outdoor unit HP-CU-200 (192 MBH cooling, 215 MBH heating), multiple ceiling cassette indoor units ranging from 8 to 24 MBH, a Dedicated Outside Air System (DOAS) unit rated at 750 CFM, two rooftop cooling units for the server room, electric duct heater, ductwork with appropriate insulation, grilles, and controls. Electrical work encompasses new lighting with recessed troffers and pendant fixtures, occupancy and photosensor controls, power distribution, data and communications rough-in, fire alarm rough-in, and emergency lighting. All equipment weights, electrical requirements, and performance specifications are detailed in the mechanical and electrical schedules. The file contains no explicit pricing information, set-aside designations, incumbent contractor data, or funding source details; these elements would be found in separate bid documents or the formal solicitation notice.

View the file

Other files

File Type Posted
IT_building_Tenant_improvement.pdf PDF
Insurance_(2).docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A-251

DOOR NUMBER DESIGNATION -

SEE DOOR SCHEDULE

ROOM NAME & NUMBER

BUILDING SECTION DESIGNATION

SHEET NUMBER WHERE SECTION APPEARS

WALL SECTION DESIGNATION

SHEET NUMBER WHERE SECTION APPEARS

SHEET NUMBER WHERE DETAIL APPEARS

DETAIL NUMBER

TYPE DESIGNATION:

W = WINDOW,

L = LOUVER

R = RELITE

CEILING HEIGHT

CEILING DESIGNATION

INTERIOR ELEVATION NUMBER(S) DESIGNATION

DIRECTION IN ROOM (FILLED ARROW)

SHEET NUMBER WHERE ELEVATION(S) APPEARS

4 2

EXTERIOR ELEVATION DESIGNATION

SHEET NUMBER WHERE ELEVATION APPEARS

Room name

1 REVISION DESIGNATION

XX

202A

LEWIS COUNTY FACILITIES DEPARTMENT

PROJECT LOCATION

AUTHORITY HAVING JURISDICTION

351 NW NORTH STREET

CHEHALIS, WA 98532

DOUG CAREY

CONTACT EMAIL: DOUG.CAREY@LEWISCOUNTY

WA.GOV

PHONE #: (360) 740-1337

COUNTY SITE PARKING

CHEHALIS, WA 98532

DOUG CAREY

CONTACT EMAIL: DOUG.CAREY@LEWISCOUNTY

WA.GOV

PHONE #: (360) 740-1337

CITY OF CHEHALIS BUILDING & PLANNING

DEPARTMENT

1321 S MARKET BLVD

CHEHALIS, WA 98532

CONTACT PERSON: CHELBI BROWNE

CONTACT EMAIL: CBROWNE@CI.CHEHALIS.WA.US

PHONE# (360) 748-0271

ARCHITECT

KMB ARCHITECTS

906 COLUMBIA STREET SW, SUITE 400

OLYMPIA, WASHINGTON 98501

JAMES HILL, RA- PRINCIPAL

360.352.8883

ELECTRICAL

HARGIS

1201 THIRD AVENUE, STE 600

SEATTLE, WA 98101

CONTACT: ERIK STEARNS

EMAIL: ERIK.STEARNS@HARGIS.BIZ

PHONE #: (206) 448-3376

MECHANICAL

HULTZ BHU

1111 FAWCETT AVENUE, SUITE 100

TACOMA, WA 98402

CONTACT: RICHARD HULTZ

EMAIL: RICKH@HULTZBHU.COM

PHONE #: (253) 383-3257

STRUCTURAL

WSP

1001 4TH AVENUE, SUITE 3100

SEATTLE, WA 98154

CONTACT: JASON TORNQUIST

EMAIL: JASON.TORNQUIST@WSP.COM

PHONE #: (206) 409-6534

LOCATION OF PROJECT

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN

ACCORDANCE WITH ALL SAFETY CODES AND REQUIREMENTS.

2. KEEP ALL AREAS UNDER CONSTRUCTION CLEAN OF DEBRIS CAUSED BY THIS

SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN

DESIGNATED AREAS.

3. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING THE SITE CONDITIONS AND

THE PLANS AND TO NOTIFY THE OWNER'S REP / ARCHITECT OF ANY ERRORS OR

OMISSIONS PRIOR TO THE START OF CONSTRUCTION.

4. DO NOT SCALE DRAWINGS. NOTIFY ARCHITECT FOR CLARIFICATION WHERE

NECESSARY.

5. CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED BY LOCAL AND STATE

GOVERNING AUTHORITIES.

6. ALL WORK SHALL MEET THE STANDARDS AND SPECIFICATIONS OF THE LOCAL AND

STATE GOVERNING AUTHORITIES. REFERENCE CODES, STANDARDS AND

AMENDMENTS SHALL BE THE EDITION MOST RECENTLY ADOPTED OR IN USE IN THE

JURISDICTION.

7. CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN FIELD AND SHALL COORDINATE

INSTALLATION OF ALL MATERIAL AND/OR EQUIPMENT WHOSE DIMENSIONS ARE

FIXED.

8. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES REQUIRED TO

PERFORM THE WORK. WHERE INSTALLATION AND/OR CONNECTION OF EQUIPMENT

IS NOT SPECIFIED AND WHERE SUCH CONNECTION AND/OR INSTALLATION IS

REQUIRED FOR A COMPLETE AND OPERABLE FACILITY, THE CONTRACTOR SHALL

BE HELD RESPONSIBLE FOR SUCH INSTALLATION AND/OR CONNECTION.

9. CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF

UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH

THE EXECUTION OF THIS WORK.

10. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION

SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN APPROVED BY THE

ARCHITECT. ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH

APPROVED SHOP DRAWINGS AND SAMPLE.

11. ALL SUBCONTRACTORS ARE RESPONSIBLE FOR REVIEWING ENTIRE SET OF

DRAWINGS AND BRINGING ANY DISCREPANCIES TO CONTRACTOR'S AND

ARCHITECT'S NOTICE DURING BIDDING.

GENERAL SEALANT NOTES

1. SEALANT OR CAULK SHALL BE USED AT JOINTS BETWEEN DIFFERENT WALL

MATERIALS (CMU TO GYPSUM BOARD, WOOD OR CASEWORK TO MASONRY,

GWB TO P-LAM, ETC).

2. SEALANT SHALL BE USED AS FILETS AT WALL INTERSECTIONS BETWEEN

WALLS, COUNTERTOPS AND BACK SPLASHES. PAINT EXPOSED ENDS OF

WOOD/PARTICLE BOARD COUNTER TOPS AND TRIM AND FULLY BED

EXPOSED EDGES AND ENDS OF COUNTERTOPS AND BACKSPLASHES

WHERE THEY MEET WALLS.

3. USE SEALANT AROUND WALL, FLOOR AND HARD CEILING PIPE

PENETRATIONS. WHERE ESCUTCHEONS ARE SPECIFIED OR PROVIDED, SET

THE ESCUTCHEON IN A BEAD OF SEALANT.

4. USE CAULK OR SEALANT AT WALL MATERIAL GAPS OF 1/16TH INCH OR

MORE UNLESS THE GAP IS SHOWN AS AN ARCHITECTURAL REVEAL.

THIS PROJECT FOR THE LEWIS COUNTY COMMUNITY DEVELOPMENT

CENTER RENOVATION PROJECT AND DOWNTOWN COUNTY CORE

IMPROVEMENTS INVOLVES THE TENANT IMPROVEMENT OF THE RAINIER

NORTH BUILDING.

THE WORK INVOLVES THE INTERIOR RENOVATION OF APPROXIMATELY

4,740 SF TO SERVE AS THE COUNTY'S IT DEPARTMENT OFFICES.

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

/3

/2

:4

8:

P M

7-31-2026

BID SET

GI001

COVER SHEET

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

LEWIS COUNTY RAINIER NORTH BUILDING TI

LEWIS COUNTY FACILITIES DEPARTMENT

351 NW NORTH STREET, CHEHALIS, WA 98532

J2037C

SCALE: N. T. S.

AREA MAP

SCALE: 1" = 400'-0"

VICINITY MAP

SHEET INDEXDESIGN TEAM - SHEET

DRAWING SYMBOLS

PROJECT INFORMATION

LOCATION OF PROJECT

PROJECT DESCRIPTION GENERAL NOTES

GENERAL

GI001 COVER SHEET

GI201 GENERAL CODE INFORMATION

ARCHITECTURAL

A-122 ENLARGED FLOOR PLAN - NORTH BUILDING

A-153 ENLARGED REFLECTIVE CEILING PLAN - NORTH BUILDING

A-251 ENLARGED PLANS & INTERIOR ELEVAITONS

A-311 WALL SECTIONS

A-502 INTERIOR WALL TYPES

A-541 DOOR AND WINDOW DETAILS

A-561 CEILING DETAILS

A-583 CASEWORK DETAILS

A-585 INTERIOR DETAILS

A-601 DOOR SCHEDULE

A-621 FINISH PLAN & SCHEDULE

STRUCTURE

S0.1 STRUCTURAL GENERAL NOTES

S1.0 STRUCTURAL FLOOR PLAN

S1.1 STRUCTURAL ROOF PLAN

S2.0 DETAILS

MECHANICAL

M-001 MECHANICAL LEGEND AND NOTES

M-002 MECHANICAL SCHEDULES

M-003 MECHANICAL SCHEDULES

M-401 FLOOR PLAN BLDG 2 - ZONING

M-402 HVAC DETAILS

M-403 HVAC DETAILS

M-404 HVAC DETAILS

M-405 VRF SYSTEM SCHEMATIC

ELECTRICAL

E0.01 ELECTRICAL LEGEND AND DRAWING INDEX

E0.02 ELECTRICAL NOTES AND ABBREVIATIONS

E0.03 ELECTRICAL SCHEDULES

E2.01 LEVEL 1 LIGHTING PLAN

E2.01A LEVEL 1 LIGHTING ZONE CONTROL PLAN

E3.01 LEVEL 1 POWER PLAN

E4.01 LEVEL 1 MECHANICAL POWER PLAN

E4.02 ROOF MECHANICAL POWER PLAN

E8.01 ELECTRICAL DETAILS

E8.02 ELECTRICAL DETAILS

E9.01 ELECTRICAL ONE-LINE DIAGRAM

E10.01 PANEL SCHEDULES

DRAWING ABBREVIATIONS

& AND

∠ ANGLE

@ AT

Ø DIAMETER

' FOOT (FEET)

" INCH

d PENNY (NAILS)

# POUNDS

⅊ PLATE or PROPERTY LINE

AB ANCHOR BOLT

ABV ABOVE

ACT ACOUSTIC CEILING TILE

AC ARCHITECTURAL CONCRETE

A/C ASPHALTIC CONCRETE

ACM ALUMINUM COMPOSITE METAL (PANELS)

AD AREA DRAIN

ADD ADDENDUM

ADJ ADJUSTABLE

AF ACCESS FLOOR

AFF ABOVE FINISH FLOOR

AFP ACOUSTICAL FIBERGLASS PANEL

AFG ABOVE FINISH GRADE

AGG AGGREGATE

AHU AIR HANDLING UNIT

ALT ALTERNATE

AMT AMOUNT

APPROX APPROXIMATE

ARCH ARCHITECT(URAL)

ASSY ASSEMBLY

AUTO AUTOMATIC

HM HOLLOW METAL

HNDRL HANDRAIL

HORIZ HORIZONTAL

HR HOUR

HSTL HOLLOW STEEL

HT HEIGHT

HTG HEATING

HTR HEATER

HV HOSE VALVE

HVAC HEATING, VENTILATING & AIR CONDITIONING

ID INSIDE DIAMETER / DIMENSION

IN INCH

INCL INCLUDED

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INV INVERT

JB JUNCTION BOX

JST JOIST

JT JOINT

L LENGTH

LAM LAMINATE

LAV LAVATORY

LB POUND OR LAG BOLT

LF LINEAR FOOT OR FEET

LH LEFT HAND

LIN LINOLEUM

LIN LINOLEUM

LL LIVE LOAD

LT LIGHT

SS STAINLESS STEEL

ST STREET

STN STAIN(ED)

STAG STAGGERED

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SURF SURFACE

SUSP SUSPENDED

SWS SEE WALL SECTIONS

SYM SYMMETRICAL

SYS SYSTEM

T TILE

THR THREAD

TEMP TEMPORARY

TEMP GL TEMPERED GLASS

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

THK THICK

THRSH THRESHOLD

THRU THROUGH

T/M TO MATCH

T/M TO MATCH

TO TOP OF

TOC TOP OF CONCRETE OR CURB

TOS TOP OF STEEL

TOT TOTAL

TYP TYPICAL

UNFIN UNFINISHED

BC BOTTOM OF CURB

BD BOARD

BFF BELOW FINISH FLOOR

BLDG BUILDING

BLK BLOCK

BLKG BLOCKING

BM BEAM OR BENCH MARK

BO BOTTOM OF

BOD BOTTOM OF DEK

BOR BOTTOM OF REVEAL

BOT BOTTOM

BRG BEARING

BR BRICK

BV BRICK VANEER

CAB CABINETRY

CB CATCH BASIN

CEM CEMENT

CG CORNER GUARD

CIP CAST IN PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONT CONTINUOUS

CORR CORRIDOR

COV PL COVER PLATE

CPT CARPET

CT CERAMIC TILE

CTR CENTER

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIFF DIFFUSER

DIM DIMENSION

DN DOWN

DR DOOR

DRN DRAIN

DS DOWNSPOUT

DT DOUBLE TREE

DWG DRAWING

E EAST

(E) EXISTING

EB EXPANSION BOLT

EJ EXPANSION JOINT

ELEC ELECTRICAL

ELEV ELEVATION

EMER EMERGENCY

ENCL ENCLOSURE

ENGR ENGINEER

EP EPOXY PAINT

ENAM ENAMEL

EQ EQUAL

EQUIP EQUIPMENT

EXH EXHAUST

EXT EXTERIOR

FA FIRE ALARM

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FIN FINISH

FLR FLOOR

FLUOR FLUORESCENT

FO FACE OF

FOF FACE OF FINISH

FOH FRONT OF HOUSE

FOC FACE OF CONCRETE

FOM FACE OF MASONARY

FOS FACE OF STUDS

FPRF FIREPROOFING

FR FIRE RESITIVE

FT FEET or FOOT

FTG FOOTING

FV FEILD VERIFY

GA GAUGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GL GLASS

GLB GLULAM BEAM

GRD GRADE

GND GROUND

GWB GYPSUM WALL BOARD

HB HOSE BIB

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

LVR LOUVER

LYRS LAYERS

M METRIC/METER

MACH MACHINE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MB MARKER BOARD

MECH MECHANICAL

MEMB MEMBRANE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MI MIRROR

MISC MISCELLANEOUS

MO MASONRY OPENING

MRG MOISTURE RESISTANT GYPSUM BOARD

MTD MOUNTED

MTL METAL

N NORTH

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NS NON-SHRINK

NTS NOT TO SCALE

OA OUTSIDE AIR

OC ON CENTER

OD OUTSIDE DIAMETER / DIMENSION

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFOI OWNER FURNISHED, OWNER INSTALLED

OPNG OPENING

OPP OPPOSITE

OPT OPTIONAL

ORIG ORIGINAL

OVHD OVERHEAD

OV OVERFLOW DRAIN

PAV PAVERS

PC PRECAST CONCRETE

PCF POUNDS PER CUBIC FOOT

PERF PERFORATED

P/L PROPERTY LINE

PL PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLUMB PLUMBING

PLF POUNDS PER LINEAL FOOT

PLYWD PLYWOOD

PNL PANEL

PRELIM PRELIMINARY

PSI POUNDS PER SQUARE INCH

P PAINT

PT PRESSURE TREATED

PTD PAINTED

QT QUARRY TILE

QTR QUARTER

R RISER

R- THERMAL RESISTANCE

RA RETURN AIR

RAD RADIUS

RB RUBBER BASE

RD ROOF DRAIN

REC RECESSED

RE: REFERENCE

REF REFRIGERATOR

REINF REINFORCE(D)(MENT)(ING)

REQD REQUIRED

REV REVISION

RF RESILIENT FLOORING

RFL REFLECTED

RM ROOM

RND ROUND

RO ROUGH OPENING

RQMT REQUIREMENT(S)

RV ROOF VENT

R/W RIGHT OF WAY

RWF RESILIENT WOOD FLOOR

S SOUTH

SC SOLID CORE

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT

SHTHG SHEATHING

SHT SHEET

SIM SIMILAR

SJ SEISMIC JOINT

SLR SEALER

SOG SLAB ON GRADE

SPEC SPECIFICATION

SQ SQUARE

UON UNLESS OTHERWISE NOTED

V VOLTAGE

V VALVE

VB VAPOR BARRIER

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VNR VENEER

VTR VENT TO ROOF

W WEST

W/ WITH

WD WOOD

WDN WINDOW

WLD WELD(ED)

WOM WALK OFF MAT

W/O WITHOUT

WP WATERPROOFING

WSCT WAINSCOT

WT WEIGHT

WTR WATER

XFRMR TRANSFORMER

YD YARD

PROPERTY INFORMATION

PROJECT NAME: LEWIS COUNTY RAINIER NORTH BUILDING TI

PARCEL NUMBER: 003752000000

SITE ADDRESS: 185 NW CHEHALIS AVE

CHEHALIS, WASHINGTON 98532

AUTHORITIES HAVING JURISDICTION

CITY OF CHEHALIS

DEPARTMENT OF BUILDING AND PLANNING

351 NW NORTH STREET

CHEHALIS, WA 98532

CODE ANALYSIS

GOVERNING CODES:

INTERNATIONAL & NATIONAL CODES:

2021 INTERNATIONAL BUILDING CODE (IBC)

2021 INTERNATIONAL MECHANICAL CODE (IMC)

2021 INTERNATIONAL FIRE CODE

2021 UNIFORM PLUMBING CODE (UPC)

2023 NATIONAL ELECTRICAL CODE

2017 ACCESSABLE AND USABLE BUILDINGS (A117.1)

WASHINGTON STATE CODES:

2021 WASHINGTON STATE ENERGY CODE CHAPTER 51-11 WAC

WASHINGTON STATE CODES AMENDMENTS:

WA STATE AMENDMENTS TO THE 2021 IBC CHAPTER 51-50 WAC

WA STATE AMENDMENTS TO THE 2021 IMC CHAPTER 51-52 WAC

WA STATE AMENDMENTS TO THE 2021 IFC CHAPTER 51-54 WAC

WA STATE AMENDMENTS TO THE 2021 UPC CHAPTER 51-56 AND 51-57 WAC

ALL AMENDMENTS, SUPPLEMENTS, MODIFICATIONS, EXCLUSIONS, EXCEPTIONS, AND

ADDITIONS TO THE CODES LISTED ABOVE AS ADOPTED BY THE WASHINGTON STATE

BUILDING CODE COUNCIL RCW 19.27 AND WAC TITLE 51.

LOCAL AMENDMENTS TO THE ABOVE LISTED CODES AND LOCAL ORDINANCE AS ADOPTED BY

THE AUTHORITY HAVING JURISDICTION: CITY OF CHEHALIS

CITY OF CHEHALIS DESIGN REQUIREMENTS

1. DESIGN WIND SPEED: 5 mph basic (Vasd) + 110 mph (Vult).

2. WIND EXPOSURE: B”

3. SEISMIC DESIGN CATEGORY: 1

4. GROUND AND ROOF SNOW LOAD: 25 psf

BUILDING CONSTRUCTION DATA:

USE AND OCCUPANCY CLASSIFICATION: BUSINESS GROUP B

CONSTRUCTION TYPE: TYPE III-B

BUILDING AREA:

NUMBER OF STORIES ALLOWED (CHAPTER 5 & TABLE 504.4):

FOR B OCCUPANCY IN CONSSTRUCTION Type III-B = 3 ; ACTUAL = 1 (EXISTING)

BUILDING HEIGHT (CHAPTER 5, TABLE 504.3):

FOR B OCCUPANCY IN CONSTRUCTIONTYPE III-B = 55 FT; ACTUAL = 19 FT (EXISTING)

ACTUAL AREA: 4,742 SF (NOT INCLUDING EXTERIOR WALL THICKNESS)

5,029 SF (INCLUDING EXTERIOR WALL THICKNESS)

ALLOWABLE AREA: FOR B OCCUPANCY IN CONSTRUCTION TYPE III-B : 19,000 SF

TOTAL GROSS BUILDING AREA = 5,029 SF

HELP DESK

719 SF

MEETING

ROOM

DIRECTOR

OFFICE

OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE

BREAK

ROOM

267 SF

91 SF 86 SF 86 SF 100 SF 84 SF 90 SF 84 SF 127 SF

159 SF

116 SF

297 SF

150 1150 1150 1150 1150 1150 1150 1150 1

150 1

150 2

150 5

15 11

15 18

14 13

13 OCCUPANTS

WIDTH REQUIRED = 1.95"

WIDTH PROVIDED = 32"

14 OCCUPANTS

WIDTH REQUIRED = 2.1"

WIDTH PROVIDED = 64"

19 OCCUPANTS

WIDTH REQUIRED = 2.85"

WIDTH PROVIDED = 32"

MTD: 108'-3"

FEC

FEC

OFFICE

150 SF

150 1

DENOTES MAXIMUM TRAVEL DISTANCE

EXIT

XX

XX XX

SQUARE FOOTAGE

OCCUPANT FACTOR / OCCUPANT LOAD

1 - HOUR FIRE WALL (EXISTING)

UL U906 (2-hr Rated)

MTD: 108'-3"

1 - HOUR FIRE RATED STEEL COLUMN

(EXISTING) UL 263, NFPA 251, ASTM E-119-106

(1-hr Rated)- APPLY INTUMESCENT PAINT PER

MANUF. RECOMMENDATIONS

ILLUMINATED EXIT SIGNAGE

FEC

FIRE EXTINGUISHER INSIDE

SURFACE MOUNT WALL CABINET

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

GI201

GENERAL CODE

INFORMATION

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

3/32" = 1'-0"1

LEVEL ONE- CODE & EXITING PLAN

CODE FLOOR PLAN LEGEND

1 2 4 5 6

A

C

B

LD

G

25'-7 3/4" VIF 18'-7 1/4" VIF 18'-7 1/4" VIF 18'-7 1/4" VIF 18'-11 1/2" VIF

A1c

A1c

A1cA1c

A1c

A1cA3cA1c

A3d

A1b

A1b

A1d

A1b

A1b

A1d

A3d

A1b

A1b A3d

A1

A1d

A1

A1d

4A

5A

6A

7A

8A

8A

0A

9A

2A

111A

2B

4A

5A

6A

7A

123A

102A

1A

HELP DESK

STORAGE

ELECTRIC

RESTROOM

CUSTODIAN

RESTROOM

SERVER

OFFICE

OFFICE

OFFICE

OFFICE

HALLWAY

OFFICE

OFFICE

OFFICE

OFFICE

HALLWAY

HALLWAY

BREAK

ROOM

OFFICE

DIRECTOR

MEETING

ROOM

A3

A1d

'-0

'-6

A

LI

G N

'-0

4'

-4

A

LI

G N

2'-0"

2' -6

'-1

A

LI

G N

4'-8 1/2" 3" 7'-6 1/2" 3'-3" 2'-3"

7B

5' -7

2'

-9

7' -3

6'-0" 9"

A-585

A-251

A-251

W2

W2

A1

A1d

A3a

2' -0

2'

-0

2' -0

3'

-0

A3a 1

A-585

A-585

A9

A9

FEC

FEC

MONITOR BY OTHERS,

OFOI REFER TO ELEC. FOR

POWER/DATA LOCATIONS.

PROVIDE BACKING IN

WALL. 5'-0" HIGH TO

CENTERLINE OF MONITOR

MONITOR BY OTHERS, OFOI REFER TO

ELEC. FOR POWER/DATA LOCATIONS.

PROVIDE BACKING IN WALL. 4'-0" HIGH

TO CENTERLINE OF MONITOR

5' -3

A-585

A-585

A3

A1c

A1b

A1

CENTER WALL ON

EXISTING COLUMN

CENTER WALL ON

EXISTING COLUMN

CENTER WALL ON

EXISTING COLUMN

A-311

A1b

'-0

MONITOR BY OTHERS,

OFOI REFER TO ELEC. FOR

POWER/DATA LOCATIONS.

PROVIDE BACKING IN

WALL. 5'-0" HIGH TO

CENTERLINE OF MONITOR

EQ EQ

HALLWAY

OFFICE

103A

124A

A1b A1b

2' -0

2'

-0

2' -0

2'

-0

W2

W2

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-122

ENLARGED FLOOR PLAN -

NORTH BUILDING

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

3/16" = 1'-0"1

ENLARGED FLOOR PLAN BLDG 2

1. ALL DIMENSIONS TO FACE OF CMU, FACE OF STUD OR GRIDLINES, U.N.O.

2. DOOR FRAMES TO BE 3" OFF ADJACENT PERPENDICULAR WALL, U.N.O.

FLOOR PLAN GENERAL NOTES

C

B

LD

G

8' - 0"

8' - 0"

8' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

9' - 0"

MEETING

ROOM

DIRECTOR

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

SERVER

ELECTRIC

STORAGE

RESTROOM

CUSTODIAN

115 RESTROOM

BREAK

ROOM

HELP DESK

HALLWAY

HALLWAY

HALLWAY

OTS

OTS

OTS

OTS

25'-7 3/4" 18'-7 1/4" 18'-7 1/4" 18'-7 1/4" 18'-11 1/2"

'-1

P M

VG

P M

VG

P M

VG

P M

VG

P M

VG

P M

VG

P M

VG

M

M

M P P

P

VG

VG

M

MP

P

M

M P

M

P

P

P P

VG

VG

HP-CU-200

HP-BC-200

HP-SBC-201

HP-112-1

HP-112-2

DH-200

DOAS-200

VG

P M

A-561

A-561

1' -0

1' -0

A-561

OTS

OTS

P

VG

VG

A-311

OFFICE

HALLWAY

9' - 0"

9' - 0"

9' - 0"

VG

VG

M

P

P

M

P

M

P

MECHANICAL SUPPLY AIR GRILLE - REFER TO

MECH. FOR SIZE AND TYPE

MECHANICAL RETURN AIR GRILLE - REFER TO

MECH. FOR SIZE AND TYPE

EXHAUST GRILLE - REFER TO MECH. FOR SIZE

AND TYPE

RECESSED CEILING TROFFER -

REFER TO ELECT.

RECESSED CEILING TROFFER -

REFER TO ELECT.

RECESSED CEILING TROFFER

W/ BATTERY BACK-UP POWER -

REFER TO ELECT.

PENDANT LIGHTING -

REFER TO ELECT.

RECESSED CAN LIGHT -

REFER TO ELECT.

CEILING ACCESS PANEL

CEILING MOUNTED ILLUMINATED

EXIT SIGN

VRF HEAT PUMP

VG

VENTILATION GRILLE

PENDANT LIGHTING

W/ BATTERY BACK-UP POWER -

REFER TO ELECT.

TRANSFER GRILLE

PHOTOSENSORP

OCCUPANCY SENSORM

CEILING TYPES: XX TYPE

X' - X" HEIGHT

ACT-1 -2x4 SUSPENDED ACOUSTICAL CEILING PANEL AND

CONCEALED GRID SYSTEM

GWB OVER STEEL STUD FRAMING

MOLD/ MOISTURE RESISTANT GYPSUM BOARD OVER STEEL

STUD FRAMING

(2) LAYERS GWB INSTALLED OVER CURRENT CEILING W/ (ACT-1)

2x4 SUSPENDED ACOUSTICAL CEILING PANEL AND CONCEALED

GRID SYSTEM

OPEN TO STRUCTURE

FULL HEIGHT WALL UP TO BOTTOM OF METAL DECKING AT ROOF ABOVE.

LOCATION OF EXTERIOR WALL ABOVE, BETWEEN LOWER AND UPPER ROOFS.

1. THESE GENERAL NOTES APPLY TO ALL REFLECTED CEILING PLANS.

2. CEILING HEIGHTS ARE FROM FINISH FLOOR UNO.

3. TYPICAL CEILING HEIGHT TO BE 9' - 0", UNO.

4. ALIGN SOFFITS WITH FACE OF ADJACENT WALL, UNO

5. NOT ALL LIGHTING, INCLUDING PENDANT AND WALL MOUNTED LIGHT FIXTURES,

SHOWN. SEE ELECTRICAL.

6. OTS = OPEN TO STRUCTURE. PAINT ALL EXPOSED CEILING/ROOF STRUCTURE, UNO.

7. U.N.O. - PAINT ALL GWB CEILINGS & SOFFITS PT-1 ( SEE FINISH SCHEDULE)

8. SEE DETAIL FOR TYP SUSPENDED GRID DETAIL..

9. INTERIOR WALLS ARE TYPICALLY 6" ABOVE CEILING HEIGHT SHOWN UNLESS NOTED

OTHERWISE ON ARCHITECTURAL OR STRUCTURAL DRAWINGS (i.e. SHEAR WALLS, SMOKE BARRIER WALLS, SOUND BARRIER WALLS, MECHANICAL ZONE WALLS).

10. COORDINATE LOCATION OF CEILING ACCESS DOORS WITH MECHANICAL &

ELECTRICAL CONTRACTORS.

11. PROVIDE ADDITIONAL EDGE BLOCKING, CROSS BRACING & SUSPENDED SUPPORT

WIRES OR ADDITIONAL FURRING FOR CEILING MOUNTED ITEMS (LIGHTING, ACCESS

PANELS, GRILLES, CAMERAS, ETC.)

FLAG NOTES TO REFLECTED CEILING PLAN:

OTS

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-153

ENLARGED REFLECTIVE

CEILING PLAN - NORTH

BUILDING

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

3/16" = 1'-0"1

LEVEL 1 - ENLARGED REFLECTIVE CEILING PLAN - BLDG 2

REFLECTED CEILING PLAN LEGEND

REFLECTED CEILING PLAN NOTES

INTERIOR ELEVATION NOTES

- SEE A-501 FOR INTERIOR WALL TYPES

- SEE A-601 FOR DOOR TYPES

ABBREV DESCRIPTION

DW-1 UNDER COUNTER DISHWASHER

(34"H X 24"W X 27"D - OFCI

FEC-1 FIRE EXTINGUISHER IN CABINET

GB-1 GRAB BAR (SIDE WALL)

GB-2 GRAB BAR (BACK WALL)

GB-3 GRAB BAR (SIDE WALL, VERTICAL)

MR-2 MIRROR

MV-1 MICROWAVE

PR-1 POWER

PTD-1 PAPER TOWEL DISPENSER

PTD/GD-1 PAPER TOWEL DISPENSER & GARBAGE DISPOSAL

R-1 REFRIGERATOR (64"H X 28"W X 34"DEEP) - OFOI

RB-1 4" HIGH RUBBER BASE

S-1 SINK

S-4 2-COMPARTMENT SINK

SD-1 SOAP DISPENSER

SND-1 SANITARY NAPKIN DISPOSAL

SSF1 SOLID SURFACE COUNTERTOP

T-1 WALL MOUNTED TOILET

TSCD-1 TOILET SEAT COVER DISPENSER

TTD-1 TOILET TISSUE DISPENSER, NAPKIN DISPOSAL

ACCESSORIES ABBREVIATION LEGEND

**REFER TO A-701 ACCESSORIES & EQUIPMENT LEGEND FOR PRODUCT INFORMATION

2' -8

1'

-6

2' -1

0"

10'-3"

1"2'-6"2'-1"3'-0"2'-6"1"

2'-6" 3'-0"

SSF1

PLAM2

PLAM2

MV-1

DW-1

RB1

PT1

SD-1

PTD-1

A-583

A-583

A-583

A-583

A-251

DW-1 MV-1

R-1

S-4

A1b

A1b

RESTROOM

CUSTODIAN

RESTROOM

A-2512 4

A-251

A-251

10A3d

A1b A1b

A1d

A3d

A1b

TB1

TL2

PT1

4' -6

SD-1

S-1

TB1

TL2

PT1

SD-1

S-1

MR-2

T-1

4' -6

TB1

TL2

PT1

T-1

PTD/GD-1

SND-1

TTD-1

TSCD-1

4' -6

TB1

TL2

PT1

4' -6

TB1

TL2

PT1

SD-1

S-1

4' -6

TB1

TL2

PT1

SD-1

S-1

MR-2

T-1

GB-3

GB-2

TB1

TL2

PT1

T-1

PTD/GD-1

SND-1

TTD-1

TSCD-1

4' -6

GB-3

GB-1

TB1

TL2

PT1

4' -6

MOP SINK

RB1

PT1

2' -4

SIDE FRONT

ACCESSIBLE WATER CLOSET

FRONT

FREESTANDING LAVATORY

PTD

FEC

T.O. RIM

BOT. BAR

BARRIER-FREE DOORS AND HARDWARE

CL

M A

X

C O

N T

R O

LS

M A

X

1'

2'

3'

1'

2' - 6"

2'

3' - 4"

4' - 6"

2' -9

1' - 6" 1' - 6"

1' - 6" 2' - 1"

MAX 42"

M A

X

4' -0

1' -6

8"

4' -2

6' -8

3' -0

3' -7

" 5' -0

FIRE PULL

ELECTRICAL

OUTLET

ROOM SIGNAGE

5' -0

HEAT SHEILD TYP

(PRE-FORMED)

SOAP

DISPENSER

MIRROR

GRAB BAR

TOILET PAPER

DISPENSER

SANITARY NAPKIN

DISPOSAL @ WOMEN

MOUNT FLUSH VAVLE

TO OPEN SIDE

WHERE OCCURS

TOILET SEAT

COVER DISPENSER

FIRE ALARM

R E

F

LE

C T

IV

E

M A

X

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-251

ENLARGED PLANS &

INTERIOR ELEVAITONS

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

1/4" = 1'-0"12

BREAK ROOM 113 - EAST ELEVATION

1/4" = 1'-0"11

ENLARGED FLOOR PLAN -

BREAK ROOM 113

1/4" = 1'-0"1

ENLARGED FLOOR PLAN - RESTROOM 114,

CUSTODIAN 115, RESTROOM 116

1/4" = 1'-0"2

RESTROOM 114 - NORTH

1/4" = 1'-0"3

RESTROOM 114 - EAST

1/4" = 1'-0"4

RESTROOM 114 - SOUTH

1/4" = 1'-0"5

RESTROOM 114 - WEST

1/4" = 1'-0"6

RESTROOM 116 - NORTH

1/4" = 1'-0"7

RESTROOM 116 - EAST

1/4" = 1'-0"8

RESTROOM 116 - SOUTH

1/4" = 1'-0"9

RESTROOM 116 - WEST

1/4" = 1'-0"10

CUSTODIAN 115 - EAST

TYPICAL MOUNTING HEIGHTS

BLDG 2 ROOF

20' - 10"

B.O. CANOPY 2

12' - 2"

LEV. 1 - BLDG 2

2' - 0 19/32"

EXISTING CONCRETE

SIDEWALK

EXISTING MASONRY WALL

EXISTING ROOF

HARD-LID CEILING

EXISTING PARAPET

OFFICE

HELP DESK

OPEN TO

HALLWAY 122

BEYOND

EXISTING WINDOW

EXISTING CANOPY

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-311

WALL SECTIONS

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

1/2" = 1'-0"1

WALL SECTION AT EAST WALL

A1

TYPICAL WALL (3 1/2" STEEL STUD)

NON-FIRE RATED

3 1/2" STEEL STUDS

@ 16" O.C.

(1) LAYER 5/8" TYPE

'X' GWB

(1) LAYER 5/8"

TYPE 'X' GWB

R-13 SOUND BATT

INSULATION, NO

INSULATION AT HALF

WALL CONDITIONS

A2 TYPICAL WALL (8" STEEL STUD) & A2a (10"

STEEL STUD)

NON-FIRE RATED

8" STEEL STUDS @

16" O.C.

(1) LAYER 5/8" TYPE

'X' GWB

(1) LAYER 5/8"

TYPE 'X' GWB

R-21 SOUND BATT

INSULATION, NO

INSULATION AT HALF

WALL CONDITIONS

A3

TYPICAL WALL (6" STEEL STUD)

NON-FIRE RATED

6" STEEL STUDS @

16" O.C.

(1) LAYER 5/8" TYPE

'X' GWB

(1) LAYER 5/8"

TYPE 'X' GWB

R-21 SOUND BATT

INSULATION, NO

INSULATION AT HALF

WALL CONDITIONS

A4

TYPICAL CHASE WALL (3 1/2" STEEL STUD)

NON-FIRE RATED

3 1/2" STEEL STUDS

@ 16" O.C.

(1) LAYER 5/8" TYPE

'X' GWB

R-13 SOUND BATT

INSULATION, NO

INSULATION AT HALF

WALL CONDITIONS

A9

TYPICAL FURRING WALL (1 5/8" STEEL STUD)

NON-FIRE RATED

1 5/8" STEEL STUDS

@ 16" O.C.

(1) LAYER 5/8" TYPE

'X' GWB

AT RESTROOMS,

ADD TBB WHERE

TILE IS TO OCCUR

AT RESTROOMS,

ADD TBB WHERE

TILE IS TO OCCUR

AT RESTROOMS,

ADD TBB WHERE

TILE IS TO OCCUR

AT RESTROOMS,

ADD TBB WHERE

TILE IS TO OCCUR

1. A 1-HR DESIGNATION INDICATED GWB MUST BE 5/8" TYPE 'X' AND MEET

1-HR WALL REQUIREMENTS PER IBC, GA, UL OR SIMILAR.

2. REFER TO FINISH SCHEDULE FOR WALL FINISH.

3. NO BATT INSULATION AT HALF WALL CONDITIONS

4. PROVIDE BACKING IN WALLS FOR CASEWORK, MESSAGE BOARDS, TOILET

ACCESSORIES, OFOI FURNISHINGS AND ALL OTHER WALL SUPPORTED

ITEMS. REFER TO INTERIOR ELEVATIONS AND PLANS FOR LOCATIONS.

5. PROVIDE BACKING AT ELECTRICAL AND COMMUNICATIONS ROOMS AS

REQUIRED PER THE ELECTRICAL REQUIREMENTS.

6. TOP AND BOTTOM PLATES: ALIGN AND ANCHOR TO BUILDING

STRUCTURAL MEMBERS AT EACH END AND AT 24" O.C.

7. WHERE METAL STUD DEFLECTION TRACKS ARE USED, PROVIDE AT TOP

OF FULL WALL HEIGHT PARTITIONS TO ALLOW STRUCTURE TO DEFLECT

WITHOUT IMPOSING LOADS ON WALL.

8. AT CEILING AND SOFFIT FRAMING:

A. INSTILL FRAMING AT 16" O.C. AND CONNECT ENDS OF STUD TO

HORIZONTAL JOIST AND SECURELY ATTACH TO BUILDING STRUCTURE

OR WALL FRAMING.

B. PARTITION CORNERS: MINIMUM OF (3) STUDS.

9. AT AIR BARRIER WALLS PROVIDE:

A. SEALANT BETWEEN PLATES AND SUBSTRATE.

B. SEALANT BETWEEN WALL AND ADJACENT VERTICAL SURFACES.

C. SEAL AIR BARRIER MEMBRANE TO ADJACENT SURFACE, FULL

PERIMETER OF WALL.

D. SEALANT AROUND ALL OPENINGS AT ELECTRICAL DEVICES, DUCTS

AND PIPING, AND STRUCTURE PENETRATING WALL SURFACES.

11. AT STC RATED WALLS, PROVIDE:

A. SEALANT BETWEEN PLATES AND SUBSTRATE.

B. SEALANT BETWEEN STUDS AND ADJACENT VERTICAL SURFACES.

C. SEALANT AROUND ALL OPENINGS AT ELECTRICAL DEVICES, DUCTS

AND PIPING, AND STRUCTURE PENETRATING SURFACES.

TOP OF WALL CONDITION

NOTE: ALL WALLS AND GWB EXTEND TO STRUCTURE, UNLESS NOTED OTHERWISE.

REFER TO PARTITION HEIGHTS BELOW FOR WALLS THAT DO NOT EXTEND TO

STRUCTURE. REFER ALSO TO STRUCTURAL SHEETS FOR LOCATIONS OF SHEAR

WALL AND REQUIRED SHEATHING.

a. PARTIAL HEIGHT PARTITION

b. PARTITION - EXTEND GWB TO 6" ABOVE UPPERMOST CEILING ON BOTH SIDES

OF WALL AND BRACE STUDS TO STRUCTURE ABOVE AS REQUIRED

c. PARTITION - EXTEND TO 12" ABOVE UPPERMOST CEILING

d. PARTITION - EXTEND STUDS TO UNDERSIDE OF STRUCTURE ABOVE. EXTEND

GWB TO 6" ABOVE CEILING ON ONE SIDE AND TO STRUCTURE ON THE OTHER

BOT. OF STRUCTURE

FINISH FLOOR

CEILING

a b cTYP, UNO

1' -0

6" d

6"

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-502

INTERIOR WALL TYPES

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

1 1/2" = 1'-0"1

INTERIOR WALL TYPES

WALL TYPE GENERAL NOTES

DOOR PER

SCHEDULE

/2

P E

R W

A L

L T

Y P

E S

/2

HOLLOW METAL FRAME

DOOR PER SCHEDULE

PER WALL TYPE

1/2"1/2"

MINERAL WOOL

BLANKET INSULATION

HOLLOW METAL FRAME

GLAZING

AND THROAT SIZE

COORD. W/ WALL TYPES

1/2" 1/2"

GWB, BOTH

SIDES TYP.

SILICONE

SEALANT

MINERAL WOOL

BLANKET

INSULATION

HOLLOW METAL

FRAME

PER WALL TYPE

HOLLOW METAL FRAME

1/2"1/2"

P E

R W

A L

L T

Y P

E S

/2

/2

HOLLOW METAL FRAME

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-541

DOOR AND WINDOW

DETAILS

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

3" = 1'-0"2

DOOR JAMB

3" = 1'-0"1

DOOR HEAD

3" = 1'-0"3

RELITE HEAD (JAMB SIM.)

3" = 1'-0"4

CASED OPENING HEAD

3" = 1'-0"5

CASED OPENING JAMB

HORIZONTAL STEEL TRACK PER

STEEL STUD MANUF.

ACOUSTICAL SEALANT AT BOTH

SIDES - PROVIDE FIRE CAULKING

AT FIRE RATED WALLS

ACOUSTICAL SEALANT AROUND

ALL WALL PENETRATIONS AT

BOTH SIDES - PROVIDE FIRE

CAULKING AT FIRE RATED WALLS

REFER TO MECHANICAL,

ELECTRICAL AND PLUMBING

DRAWINGS FOR PIPE AND

DUCTWORK LOCATIONS

5/8" TYPE "X" GWB - REFER TO

INTERIOR ELEVATIONS FOR FINISH

- REFER TO WALL TYPES FOR

ALTERNATE SUBSTRATE TYPES

PER WALL TYPE

STEEL STUDS @ 16" O.C.

W/ BATT INSULATION PER

WALL TYPE

LINE OF STRUCTURE ABOVE (CLT ROOFING /

FLOOR JOISTS / BOTTOM CORD OF ROOF TRUSS)

REFER TO WALL TYPES FOR

ALTERNATE SUBSTRATE TYPES

PER WALL TYPE

STEEL STUDS @ 16" O.C.

W/ BATT INSULATION PER

WALL TYPE

5/8" TYPE "X" GWB - REFER TO

INTERIOR ELEVATIONS FOR FINISH

- REFER TO WALL TYPES FOR

ALTERNATE SUBSTRATE TYPES

LINE OF STRUCTURE ABOVE

(CLT ROOFING / FLOOR JOISTS / WOOD TRUSS BOTTON CORD)

STEEL BRACE FRAMING AT EACH

SIDE OF WALL @ 4'-0" O.C.

ALTERNATING

HORIZONTAL STEEL TRACK

PER STEEL STUD MANUF.

ACOUSTICAL CEILING PER

REFLECTED CEILING PLAN

REFER TO WALL TYPES FOR

ALTERNATE SUBSTRATE TYPES

PER WALL TYPE

STEEL STUDS @ 16" O.C. W/ BATT

INSULATION PER WALL TYPE

LINE OF STRUCTURE ABOVE

(CLT ROOFING / FLOOR JOISTS / WOOD TRUSS BOTTON CORD)

CEILING PER REFLECTED

CEILING PLAN

DOUBLE TOP PLATE

ACOUSTICAL CEILING PER

REFLECTED CEILING PLAN

5/8" TYPE "X" GWB - REFER TO

INTERIOR ELEVATIONS FOR FINISH

STEEL BRACE FRAMING AT

EACH SIDE OF WALL @ 4'-0"

O.C. ALTERNATING

8" MAX

3" M

A X

8" MAX

3" M

A X

45°

45°

ATTACHED GRID UNATTACHED GRID

NOTES:

1. INSTALL SYSTEM IN ACCORDANCE W/ THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE.

2. SUPPLY COMPRESSION STRUTS AT GRID INTERSECTION ADJACENT TO LATERAL BRACING POINTS.

3. SUPPLY ADDITIONAL 12GA WIRES FOR LIGHT FIXTURES AND MECHANICAL SERVICE INDEPENDENT OF GRID SUSPENSION SYSTEM.

4. ACCOUSTICAL MATERIALS SHALL COMPLY W/ INTERIOR FINISH REQUIREMENTS OF THE LATEST EDITIONS OF THE INTERNATIONAL

BUILDING CODE.

12 GA. VERT. HANGER WIRE

(MIN) @ 4'-0" O.C. BOTH WAYS

COMPRESSION STRUT 12'-0" O.C.

POSITIVELY ATTACHED TO GRID

AND STRUCTURE

LATERAL FORCE BRACING 4 EA 12

GA. WIRE SECURED TO MAIN RUNNER

WITHIN 2" OF CROSS TEE

INTERSECTION & SPLAYED 90° FROM

EA OTHER @ 12'-0" O,C, IN BOTH

DIRECTIONS W/ FIRST POINT WITHIN

6'-0" OF PERIMETER WALLS

MAIN RUNNERCROSS TEE

12GA (MIN) VERT PERIMETER

HANGING WIRE (TYP)

3 TURNS MIN (TYP)

MAIN RUNNER OR

CROSS TEE

ACOU. TILE

ATTACH GRID MEMBERS TO PERIMETER

WALL AT ANGLE & TWO ADJ WALLS ONLY

2" x 1" WALL ANGLE

3/4" AT UNATTACHED

GRID ENDS

PER WALL TYPE

STEEL STUDS @ 16" O.C.

W/ BATT INSULATION PER

WALL TYPE

5/8" TYPE "X" GWB

- REFER TO INTERIOR

ELEVATIONS FOR FINISH

ACOUSTICAL CEILING PER

REFLECTED CEILING PLAN

ACOUSTICAL CEILING PER

REFLECTED CEILING PLAN

HEIGHT PER RCP

EXISTING STRUCTURE

STEEL STUDS @ 16" O.C.

5/8" TYPE "X" GWB

- REFER TO FINISH SCHEDULE

ACOUSTICAL CEILING PER

REFLECTED CEILING PLAN

ALIGN

6"

ALIGN

HEIGHT PER RCP

EXISTING STRUCTURE

1'-0"

STEEL STUDS @ 16" O.C.

5/8" TYPE "X" GWB

- REFER TO FINISH SCHEDULE

ALIGN

HEIGHT PER RCP

EXISTING STRUCTURE

1'-0"

ACOUSTICAL CEILING PER

REFLECTED CEILING PLAN

ALIGN

6"

2X WOOD STUDS @ 16" O.C.

5/8" TYPE "X" GWB

- REFER TO FINISH SCHEDULE

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-561

CEILING DETAILS

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

3" = 1'-0"1

WALL TYPE DETAIL @ FULL HEIGHT TO STRUCTURE

3" = 1'-0"2

WALL TYPE DEATIL @ BRACED WALL & ACT BOTH SIDES

3" = 1'-0"3

WALLTYPE DEATIL @ BRACED WALL @ GWB/ACT CEILING

1 1/2" = 1'-0"4

SUSPENDED CEILING SYSTEM - TYP.

3" = 1'-0"5

CEILING DETAIL @ ACOUSTICAL CEILING BOTH SIDES

1 1/2" = 1'-0"6

CEILING DETAIL @ SOFFIT

1 1/2" = 1'-0"7

CEILING DETAIL @ WINDOW

1 1/2" = 1'-0"8

CEILING DETAIL - GWB TO ACT TRANSITION @ PERIMETER

1/4" BACK

SECURE TO

WALL FRAMING

AND BACKING

CABINET (BOX) CONSTRUCTED FROM

3/4" SUBSTRATE, WHITE MELAMINE

FACED @ INTERIOR - TYPICAL

FRENCH

CLEAT

96MM WIRE PULL TYP, UNO

P-LAM FINISH PER INTERIOR

ELEVATIONS ON ALL EXPOSED

SIDES OF DOOR

3/4" WHITE MELAMINE ADJ.

SHELF, TYP.

BLUM 120° CONCEALED

HINGES, TYP.

SOLID 2x

BLOCKING

ADJ. SHELF

ADJ. SHELF

S E

E

IN

TE

R

IO

R

E

LE

V A

TI

O

N S

3"

2"

1'-3"

APPLY BASE PER

FINISH SCHEDULE

SCRIBE TO WALL SURFACE

SOILID SURFACE COUNTERTOP

AS SPECIFIED OVER PLYWOOD

BACKSPLASH WHERE OCCURS -

SEE INTERIOR ELEVATIONS

MARINE GRADE PLYWOOD

TOE BOX, TYPICAL

3"

96MM WIRE

PULL, TYP

3/4" WHITE MELAMINE

ADJ. SHELF, TYP.

ADJ. SHELF

4"

4"

REFER TO INTERIOR ELEVATION

R E

F E

R T

O

IN

T E

R

IO

R E

LE

V

A T

IO

N

4"

1/ 8"

6" 1/ 4"

1/

2"

3/4" IPB SCREW RAIL

(SECURED TO WALL VIA

THROUGH CABINET

MECH. FASTENERS)

SOLID 2x BLOCKING

NOTES:

• FULLY WELD BRACE ASSEMBLY,

GRIND WELDS SMOOTH

• PROVIDE BRACE SO NO COUNTER

SPAN IS GREATER THAN 3'-6"

TUBE STEEL BRACE, PAINT

TO MATCH WALL COLOR

HOLES FOR FASTENERS

@ SURFACE MOUNT

CONDITIONS, TYP.

BEVEL BOTTOM

EDGE

ANGLE FRONT EDGE

HOLES FOR FASTENERS @

CONCEALED CONDITIONS, TYP.

1' -9

5/

4" L

ESS THAN W

IDTH OF COUNTER

SCRIBE TO

WALL SURFACE

SOLID SURFACE COUNTERTOP

AS SPECIFIED

BACKSPLASH WHERE OCCURS -

SEE INTERIOR ELEVATIONS

MARINE GRADE PLYWOOD

TOE BOX, TYPICAL

S E

E

IN

TE

R

IO

R

E

LE

V A

TI

O

N S

1/

2"

DOOR LOCK, TYP

96MM WIRE PULL, TYP

FIN. FLOOR: INSTALL

BEFORE CASEWORK, TYP

4"

WHITE MELAMINE

INTERIOR, TYP.

6"

FIXED PANEL

ACTUAL SINK

ATTACHMENT TO

COUNTERTOP PER

MANUF/FABRICATOR

SEAMLESS, INTEGRAL SOLID

SURFACE SINK PER MECHANICAL

4"

MAINTAIN CLEAR TOE

KICK

REFER TO INTERIOR ELEVATION

1 1/2" x 1/8" SQ. TUBE STEEL

BRACE, PAINT. INSTALL BRACE

WHERE INDICATED AND @ 42"B

MAX. AT ALL UNSUPPORTED

COUNTERTOPS

ANGLE AND CAP AT TOP

AND BOTTOM AS SHOWN

3/8" DIA FASTENERS, TYP

1x WALL CLEAT

SOLID STEEL

STUD BLOCKING

FIN. FLOOR: INSTALL

BEFORE CASEWORK, TYP

BASE PER FINISH

SCHEDULE

4"

SCRIBE TO WALL SURFACE

SOILID SURFACE COUNTERTOP

AS SPECIFIED OVER PLYWOOD

BACKSPLASH WHERE OCCURS -

SEE INTERIOR ELEVATIONS

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-583

CASEWORK DETAILS

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

1 1/2" = 1'-0"3

UPPER CABINET

1" = 1'-0"1

BASE CABINET W/ DOOR AND DRAWER

1 1/2" = 1'-0"5

TYPICAL COUNTERTOP BRACE

1" = 1'-0"2

BASE CABINET W/ SINK

1" = 1'-0"4

CASEWORK DETAIL @ COUNTERTOP

BACKING

WAINSCOT

BELOW

SEALANT

22 GA. BREAK METAL

OVER 3/8" MDF, MT2.

GRAB BAR

ASSEMBLY

GRAB BAR

ASSEMBLY

22 GA. BREAK METAL

OVER 3/8" MDF

NOTE: SPACER TO MATCH

THICKNESS OF WAINSCOT

BELOW

PLAN VIEW

ELEV.

CL

(3) STEEL STUD SUPPORT

BACKING AT GRAB BAR

CONNECTIONS

W A

LL

P

E R

P

LA

N

1/2"

RADIUS

REFER TO ROOM SIGN

X/A-XX FOR DETAIL

PROVIDE BRUSHED ALUMINUM (HORIZONTAL) PLATE ON

OPPOSITE SIDE OF GLAZING. 10" W X 8 3/4" H TO MATCH

SIGN FACE.

SECTION ELEVATION FRONT ELEVATION

NOTE: PICTOGRAM IN WHITE BACKGROUND

IN BLUE PER IBC 2015 (WAC 2015) 1101.2.6

(ICC A117.1 SECTION 703.6.3.1)

SIGN FACE.

HOLLOW METAL DOOR FRAME

SIDELITE GLAZING

MAXIMUM OCCUPANCY

XX PERSONS

1/

2"

1'-5"

O F

T E

X T

1" T

O T

O P

FONT SIZE: 1 INCH

FONT STYLE: ARIAL

REFER TO 1/G1201- CODE &

EXITING PLAN FOR

OCCUPANY LOADS

ROOM NAME

GRADE II BRAILLE

FONT SIZE: 3/4 INCH

FONT STYLE: ARIAL

10"

3"

O F

T E

X T

1" T

O T

O P

8"

9"

FONT SIZE: 3/4 INCH

FONT STYLE: ARIAL

GRADE II BRAILLE

SOLID COLOR ACRYLIC PLACARD

IN INTERNATIONAL BLUE, TYP.

EQ

PICTOGRAM O.C.

HORIZONTALLY EQ

NOTE: PICTOGRAM IN WHITE BACKGROUND

IN BLUE PER IBC 2015 (WAC 2015) 1101.2.6

(ICC A117.1 SECTION 703.6.3.1)

RESTROOM

1" 4"

1/ 4"

1" 3/

4" 2"

SIGN TO BE LOCATED AT ALL

RESTROOMS

7"

ACCESS FLOOR PER

MANUFACTURER

1/

2"

3/4"

RUBBER BASE

PARTIAL WALL,

REFER TO FLOOR PLAN FOR TYPE

1X2 WOOD TRIM

SOLID SURFACE ON 3/4" PLYWOOD

PER MANUFACTURER

(2) 3/4 T&G PLYWOOD

2X TREATED BLOCKING

@ 16" O.C.

EXISTING CONCRETE

FINISH AS INDICATED

IN FINISH PLAN

STAINLESS STL TRANSITION STRIP

SCHLUTER RENO RAMP 100B65 OR SIM.

(E) CONCRETE FLOOR SLAB

TILECONCRETE

TRANSITION STRIP ROPPE 67 OR SIM.

(E) CONCRETE FLOOR SLAB

CARPET /

LINOLEUMCONCRETE

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-585

INTERIOR DETAILS

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

3" = 1'-0"8

GRAB BAR DETAIL

3" = 1'-0"6

ROOM SIGN @ SIDELITE

3" = 1'-0"5

MAXIMUM OCCUPANCY SIGNAGE

3" = 1'-0"4

ROOM SIGN

3" = 1'-0"7

UNISEX RESTROOM SIGN

1 1/2" = 1'-0"3

ACCESS FLOOR DETAIL

1" = 1'-0"1

HALF WALL SECTION

1 1/2" = 1'-0"2

FLOOR INFILL

3" = 1'-0"9

FLOOR TRANSITIONS

DOOR NOTES

ABBREVIATIONS

ALUM ALUMINUM

CC CLEAR COAT

FF FACTORY FINISH

FIN FINISH

H HEIGHT

HM HOLLOW METAL

MATL MATERIAL

MFG MANUFACTURER

N/A NOT APPLICAPLE

• PRE-FINISH = FINISHED BY MANUFACTURER TO MATCH KAWNEER BURGUNDY

• REFER TO INTERIOR FINISH SCHEDULE FOR PAINT SPECIFICS.

DOOR AND FRAME GENERAL NOTES

1. DOOR & FRAME SCHEDULE NOTES APPLY TO ALL DOOR & FRAME SCHEDULES.

2. DIMENSIONSOF ALL OPENINGS TO BE FIELD VERIFIED PRIOR TO FABRICATION.

3. PROVIDE 1/2" MAX SHIM SPACE AT HEAD, JAMB AND SILL AT OPENINGS.

4. FRAME MANUFACTURER SHALL COORDINATE LOCATIONS OF CONCEALED

CONDUIT & J-BOXES FOR SYSTEM HARDWARE PRIOR TO MANUFACTURING OF

FRAMES & COORDINATE WITH ASSOCIATED HARDWARE & DEVICES.

5. SEE SPECIFICATIONS SECTION 08 71 00 DOOR HARDWARE FOR DOOR HARWARE

SET NOTED IN DOOR SPECIFICATIONS OPENING SCHEDULE.

6. GLASS TYPES FOR DOORS AND FRAMEARE INDICATED. REFER TO STOREFRONT

TYPES & FRAME TYPES & DOOR SCHEDULE. SEE SPECIFICATIONS DIVISION 08

SECTIONS FOR GLASS TYPE DESCRIPTIONS AND GLASS NOTES FOR

ABBREVIATIONS.

7. ALL HOLLOW METAL DOORS AND FRAMES ARE TO BE PAINTED.

P PAINT

R RELITE

PR PAIR

SIM SIMILAR

STL STEEL

TEMP TEMPERED

THCK THICKNESS

W WIDTH

WD WOOD

F.F.

FLUSH - INSULATED

HOLLOW METAL DOOR

H E

IG

H

T

WIDTH

A NARROW LITE -

INSULATED HOLLOW

METAL DOOR

B

H E

IG

H

T P

E R

S C

H E

D U

L E

WIDTH

4" 8"

3' -4

3'

-0

8"

H E

IG

H

T P

E R

S C

H E

D U

L E

PER SCHED.

WIDTH

FULL LITE - INSULATED

HOLLOW METAL DOOR

C

6" 2'-0" 6"

5' -6

8"

H E

IG

H

T P

E R

S C

H E

D U

L E

PER SCHED.

WIDTH

F

1/2" CLEAR

TEMPERED

GLAZING

3' -6

8"

HALF LITE

6" 6"

F.F.

2' - 0"

W1

A-541

D O

O R

H E

IG

H

T

2" DOOR WIDTH 2"

F.F.

HOLLOW METALF1

A-541

A-541

D O

O R

H E

IG

H

T

2" DOOR WIDTH 2"

CASED OPENINGF5

A-541

A-541

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-601

DOOR SCHEDULE

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

GENERAL DOOR NOTES

1. ALL DOOR HARDWARE TO CONFORM WITH A.D.A. STANDARDS.

2. ALL DOOR HARDWARE HEIGHTS TO CONFORM WITH A.D.A. STANDARDS.

3. PRIOR TO CONSTRUCTION, SUBMIT DOOR HARDWARE TO ARCHITECT FOR APPROVAL.

4. CONFIRM DOOR FRAME DIMENSIONS AND COMPATIBILITY WITH DOOR HARDWARE PRIOR TO

IMPLEMENTATION.

5. SHOP PRIME ALL HOLLOW METAL FRAMES.

6. REFER TO FINISH LEGEND FOR ALL DOOR AND FRAME FINISH REFERENCES.

7. PROVIDE ACOUSTICAL INSULATION AND SEALANTS AT DOOR AND RELITE FRAMES INSTALLED IN

STC-RATED WALL ASSEMBLIES.

8. DOORS THAT ARE NOT AUTOMATIC SHALL HAVE ACCESSIBLE FEATURES AND HARDWARE PER

CURRENT IBC AND ANSI 117

9. EXITING DOORS SHALL HAVE APPROVED PANIC HARDWARE PER CURRENT IBC

10. TACTILE SIGNS SHALL BE INSTALLED AS PER CURRENT IBC AND ANSI 117

DOOR SCHEDULE - BUILDING 2

DOOR

NO.

DOOR FRAME

HDW COMMENTSW H TYPE THCK MATL FIN GLASS TYPE MATL FIN GLASS

101A 3' - 0" 7' - 0" C 1 3/4" WD CC TEMP F1 HM P - - 6

102A 3' - 0" 7' - 0" C 1 3/4" WD CC TEMP F1 HM P - - 6

103A 3' - 0" 7' - 0" C 1 3/4" WD CC TEMP F1 HM P - - 8

104A 3' - 0" 7' - 0" F 1 3/4" WD CC TEMP F1 HM P - - 6

105A 3' - 0" 7' - 0" F 1 3/4" WD CC TEMP F1 HM P - - 6

106A 3' - 0" 7' - 0" F 1 3/4" WD CC TEMP F1 HM P - - 6

107A 3' - 0" 7' - 0" F 1 3/4" WD CC TEMP F1 HM P - - 6

108A 3' - 0" 7' - 0" F 1 3/4" WD CC TEMP F1 HM P - - 6

109A 3' - 0" 7' - 0" F 1 3/4" WD CC TEMP F1 HM P - - 6

110A 3' - 0" 7' - 0" F 1 3/4" WD CC TEMP F1 HM P - - 6

111A 3' - 0" 7' - 0" C 1 3/4" WD CC TEMP F1 HM P - - 6

112A 3' - 0" 7' - 0" A 1 3/4" WD CC - - F1 HM P - - 14

112B 3' - 0" 7' - 0" A 1 3/4" WD CC - - F1 HM P - - 14

114A 3' - 0" 7' - 0" A 1 3/4" WD CC - - F1 HM P - - 4

115A 3' - 0" 7' - 0" A 1 3/4" WD CC - - F1 HM P - - 9

116A 3' - 0" 7' - 0" A 1 3/4" WD CC - - F1 HM P - - 4

117A 3' - 0" 7' - 0" A 1 3/4" WD CC - - F1 HM P - - 14

117B 3' - 0" 7' - 0" A 1 3/4" WD CC - - F1 HM P - - 14

118A 3' - 0" 7' - 0" A 1 3/4" WD CC - - F1 HM P - - 14

123A 3' - 0" 7' - 0" C 1 3/4" WD CC TEMP F1 HM P - - 17

124A 3' - 0" 7' - 0" F 1 3/4" WD CC TEMP F1 HM P - - 6

1/4" = 1'-0"3

DOOR TYPES

1/4" = 1'-0"2

RELITE TYPES

1/4" = 1'-0"1

FRAME TYPES

CONC - SEALED CONCRETE

LINO2 - LINOLEUM

CPT2 - CARPET

TL1 - TILE

MATERIAL TRANSITION STRIP

CORNER GAURD

FLOOR FINISHES

CONC - GROUND AND SEALED CONCRETE

LINO2 - LINOLEUM - FORBO, MARMOLEUM, STYLE: REAL, COLOR: MIST GREY

CPT2 - CARPET - MANNINGTON, STYLE: SKETCH, COLOR: BOROUGH

TL1 - TILE - DALTILE, STYLE: PORTFOLIO, 12" X 24", COLOR: ASH GREY

BASE FINISHES

RB1 - RUBBER BASE - ARMSTRONG, STYLE: COVED WALL BASE, COLOR:

FLAGSTONE

RB3 - RUBBER BASE - ARMSTRONG, STYLE: COVED WALL BASE, COLOR: GRAY

MIST

TB1 - BASE TILE - DALTILE, STYLE: PORTFOLIO, COVE BASE, COLOR: ASH

GREY

WALL FINISHES

PT1 - PAINT - SHERWIN WILLIAMS, COLOR: 0054 TWILIGHT GREY

TL2 - WALL TILE - DALTILE, STYLE: PORTFOLIO, 6" X 24", COLOR: ASH GREY

CASEWORK FINISHES

PLAM2 - PLASTIC LAMINATE - WILSONART, COLOR: BRAZILWOOD

SSF1 - SOLID SURFACE - WILSONART, COLOR: CHILLED EARTH

CEILING FINISHES

ACT1 - 2X4 ACOUSTIC CEILING TILE - ARMSTRONG, STYLE: CIRRUS SECOND

LOOK II

R E

F E

R T

O A

-1

R E

F E

R T

O A

-1

HELP DESK

STORAGE

ELECTRIC

RESTROOM

CUSTODIAN

RESTROOM

SERVER

OFFICE

OFFICE

OFFICE

OFFICE

HALLWAY

OFFICE

OFFICE

OFFICE

OFFICE

HALLWAY

HALLWAY

BREAK

ROOM

OFFICE

DIRECTOR

MEETING

ROOM

A-585

A-585

A-585

A-585

OFFICE

HALLWAY

1. ALL INTERIOR SHALL MEET THE CURRENT IBC FOR FLAME SPREAD AND

SMOKE DEVELOPMENT MINIMUM STANDARDS.

2. REFER TO 9/A-585 FOR TYPICAL FLOOR TRANSITIONS

906 Columbia Street SW, Suite 400

Olympia, Washington 98501

360.352.8883 architects

KMB Project #

SHEET NO.

REVISIONS:

DATE:

ORIGINAL SHEET SIZE = 24 x 36

HALF SIZE REDUCTIONS = 11 x 17

P

LO

T D

A T

E

ARCHITECT

STATE OF WASHINGTON

REGISTERED

JAMES HILL

10347

/3

/2

:4

8:

P M

7-31-2026

BID SET

A-621

FINISH PLAN & SCHEDULE

LE

W

IS

C

O U

N

TY

R A

IN

IE

R N

O R

TH

B

U

IL

D

IN

G T

I

LE

W

IS

C O

U N

TY

F

A C

IL

IT

IE

S

D

EP

A R

TM

EN

T

N W

N O

R

TH

S

TR

EE

T, C H

EH

A

LI

S

, W A

Fa ci lit ie s D ep ar tm en t

J2037C

LEGEND-FINISH PLAN

INTERIOR FINISH SCHEDULE

FINISH SCHEDULE - BUILDING 2

ROOM

NO. ROOM NAME

FLOOR

FINISH

BASE

FINISH

NORTH WALL EAST WALL SOUTH WALL WEST WALL

NOTESMATL FIN MATL FIN MATL FIN MATL FIN

101 OFFICE CPT2 RB1 PT1 PT1 PT1 (EXISTING)

102 DIRECTOR CPT2 RB1 (EXISTING) PT1 PT1 (EXISTING)

103 MEETING ROOM CPT2 RB1 (EXISTING) (EXISTING) PT1 PT1

104 OFFICE CPT2 RB1 PT1 (EXISTING) PT1 PT1

105 OFFICE CPT2 RB1 PT1 (EXISTING) PT1 PT1

106 OFFICE CPT2 RB1 PT1 (EXISTING) PT1 PT1

107 OFFICE CPT2 RB1 PT1 (EXISTING) PT1 PT1

108 OFFICE CPT2 RB1 PT1 (EXISTING) PT1 PT1

109 OFFICE CPT2 RB1 PT1 (EXISTING) PT1 PT1

110 OFFICE CPT2 RB1 PT1 (EXISTING) PT1 PT1

111 OFFICE CPT2 RB1 PT1 (EXISTING) (EXISTING) PT1

112 SERVER CONC RB1 PT1 PT1 (EXISTING) PT1

113 BREAK ROOM LINO2 RB1 PT1 PT1 (EXISTING) (EXISTING)

114 RESTROOM TL1 TB1 TL2 / PT1 TL2 / PT1 TL2 / PT1 TL2 / PT1

115 CUSTODIAN CONC RB1 PT1 PT1 PT1 PT1

116 RESTROOM TL1 TB1 TL2 / PT1 TL2 / PT1 TL2 / PT1 TL2 / PT1

117 STORAGE CONC RB1 PT1 PT1 PT1 PT1

118 ELECTRIC CONC RB1 PT1 PT1 PT1 PT1

119 HELP DESK CONC RB1 - - PT1 PT1 PT1

120 HALLWAY CONC RB1 PT1 PT1 - - (EXISTING)

121 HALLWAY CONC RB1 PT1 PT1 - - PT1

122 HALLWAY CONC RB1 PT1 PT1 PT1 PT1

123 HALLWAY CONC RB1 PT1 (EXISTING) PT1 PT1

124 OFFICE CPT2 RB1 (EXISTING) PT1 PT1 PT1

1/8" = 1'-0"1

ENLARGED FLOOR PLAN BLDG 2 - FINISH PLAN

NOTES - FINISH PLAN

STRUCTURAL ABBREVIATIONS:

H HORIZONTAL

HC HOLLOW CORE (PRECAST PRESTRESSED)

HD HOLD DOWN

HDR HEADER

HF HEM FIR

HGR HANGER

HK HOOK

HP HP SHAPE

HORIZ HORIZONTAL

HS HEADED ANCHOR STUD

HSS HOLLOW STRUCTURAL SECTION

HT HEIGHT

CBC INTERNATIONAL BUILDING CODE

ID INSIDE DIAMETER

IF INSIDE FACE

IN INCH

INFO INFORMATION

INT INTERIOR

JST JOIST

JT JOINT

K KIP (1,000 LBS)

KSI KIPS PER SQUARE INCH

KSF KIPS PER SQUARE FOOT

L ANGLE

LB POUND

LD DEVELOPMENT LENGTH

LDH HOOKED BAR DEVELOPMENT LENGTH

LF LINEAR FOOT

LFRS LATERAL FORCE RESISTING SYSTEM

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LOC LOCATION OR LOCATE

LONG LONGITUDINAL

LSL LAMINATED STRAND LUMBER OR LONG SLOTTED (HOLES)

LT WT LIGHTWEIGHT

LVL LAMINATED VENEER LUMBER OR LEVEL

LWC LIGHT WEIGHT CONCRETE

MATL MATERIAL

MAX MAXIMUM

MB MACHINE BOLT

MC MISCELLANEOUS CHANNEL

MECH MECHANICAL

MEP MECHANICAL, ELECTRICAL, AND PLUMBING

MEZZ MEZZANINE

MF MOMENT FRAME

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MK MARK

MOM MOMENT

MTL METAL

MWFRS MAIN WIND FORCE RESISTING SYSTEM

(N) NEW

N NORTH

N/S NORTH/SOUTH

NIC NOT IN CONTRACT

NLT NAIL LAMINATED TIMBER

NO NUMBER

NOM NOMINAL

NS NEAR SIDE OR NON-SHRINK

NTS NOT TO SCALE

NWC NORMAL WEIGHT CONCRETE

OC ON CENTER

OCBF ORDINARY CONCENTRIC BRACED FRAME

OD OUTSIDE DIAMETER

OF OUTSIDE FACE

OPNG OPENING

OPP OPPOSITE OR OPPOSITE HANDED

OPT OPTION OR OPTIONAL

OVS OVERSIZED (HOLE)

P PIPE

P/C PRECAST CONCRETE

PAF POWDER ACTUATED FASTENER

PAR PARAPET OR PARALLEL

PC PILE CAP OR PIECE

PCF POUNDS PER CUBIC FOOT

PEN PENETRATION

PERP PERPENDICULAR

PJP PARTIAL JOINT PENETRATION

PL PLATE

PLF POUNDS PER LINEAR FOOT

PLYWD PLYWOOD

PNL PANEL

PREFAB PREFABRICATED

PROJ PROJECTION

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PSL PARALLEL STRAND LUMBER (PARALLAM)

PT PRESSURE TREATED OR POST TENSIONED OR POINT

R RADIUS

RBS REDUCED BEAM SECTION

RC REINFORCED CONCRETE

REBAR REINFORCING BAR

REF REFERENCE OR REFER TO

REINF REINFORCE OR REINFORCING (STEEL)

REM REMAIN OR REMAINDER

REQ’D REQUIRED

RET RETAINING

RND ROUND

RO ROUGH OPENING

RTN RETURN

S SOUTH

SAD SEE ARCHITECTURAL DRAWINGS

SC SLIP CRITICAL

SCBF SPECIAL CONCENTRIC BRACED FRAME

SCHED SCHEDULE

SDQ SPECIAL DUCTILE QUALITY

SDS SELF-DRILLING SCREW

SECT SECTION

SEOR STRUCTURAL ENGINEER OF RECORD

SFRS SEISMIC FORCE RESISTING SYSTEM

SHT SHEET

SHTG SHEATHING

SIM SIMILAR

SMF SPECIAL MOMENT FRAME

SOG SLAB ON GRADE

SOMD SLAB ON METAL DECK

SP SPACE OR SPACES

SPEC SPECIFICATION

SQ SQUARE

STRUCTURAL ABBREVIATIONS:

& AND

@ AT

° OR DEG DEGREES

Ø OR DIA DIAMETER

# NUMBER OR POUND

± PLUS OR MINUS

AB ANCHOR BOLT (IN CONCRETE)

ADD’L ADDITIONAL

AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL

AFF ABOVE FINISH FLOOR

AGG AGGREGATE

AHJ AUTHORITY HAVING JURISDICTION

ALT ALTERNATE

ALUM ALUMINUM

ANCH ANCHOR

ARCH’L ARCHITECTURAL

APPROX APPROXIMATE

AVG AVERAGE

B BOTTOM BARS

B/ BOTTOM OF

BF BRACED FRAME

BLDG BUILDING

BLKG BLOCKING

BM BEAM

BOD BOTTOM OF DECK

BOF BOTTOM OF FOOTING

BOS BOTTOM OF STEEL

BOT BOTTOM

BP BASE PLATE

BRB BUCKLING RESTRAINED BRACE

BRBF BUCKLING RESTRAINED BRACED FRAME

BRG BEARING

BSMT BASEMENT

BTWN BETWEEN

BU BUILT UP

C CHANNEL OR CAMBER

C/C CENTER TO CENTER

C&C COMPONENTS AND CLADDING

CANT CANTILEVER

CB CASTELLATED BEAM

CFMF COLD-FORMED METAL FRAMING

CG CENTER OF GRAVITY

CIP CAST IN PLACE

CJ CONSTRUCTION JOINT

CJP COMPLETE JOINT PENETRATION

CL CENTERLINE

CLG CEILING

CLR CLEAR OR CLEARANCE

CLT CROSS LAMINATED TIMBER

CMU CONCRETE MASONRY UNIT

COL COLUMN

COMP COMPRESSION

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUOUS

COORD COORDINATE

CTR CENTER OR CENTERED

CY CUBIC YARD

D PENNY (NAIL)

DB BAR DIAMETER OR DIVIDER BEAM

DBA DEFORMED BAR ANCHOR

DBL DOUBLE

DEG DEGREE OR DEGREES

DEMO DEMOLISH OR DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DEV DEVELOPMENT

DF DOUGLAS FIR

DIA DIAMETER (ALSO SHOWN AS Ф)

DIAG DIAGONAL

DIAPH DIAPHRAGM

DIM DIMENSION

DIST DISTANCE

DL DEAD LOAD

DLT DOWEL LAMINATED TIMBER

DN DOWN

DO DITTO

DP DEEP OR DEPTH

DT DOUBLE TEE (PRESTRESSED PRECAST)

DWG DRAWING

DWL DOWEL

(E) EXISTING

E EAST

E/W EAST/WEST

EA EACH

EF EACH FACE

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR OR ELEVATION

EMBED EMBEDDED

ENGR ENGINEER

EOR ENGINEER OF RECORD

EOS EDGE OF SLAB

EQ EQUAL OR EARTHQUAKE

EQUIP EQUIPMENT

ES EACH SIDE

ETC ET CETERA

EW EACH WAY

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

FB FLAT BAR

FF FINISH FLOOR

FIN FINISH OR FINISHED

FL FLOOR

FLG FLANGE

FN FACE NAIL

FNDN FOUNDATION

FRP FIBER REINFORCED POLYMER

FRT FIRE RETARDANT TREATED

FS FAR SIDE

FT FOOT OR FEET

FTG FOOTING

GA GAUGE

GALV GALVANIZED

GB GRADE BEAM

GC GENERAL CONTRACTOR

GEN GENERAL

GEOTECH GEOTECHNICAL

GLB GLUE LAMINATED BEAM

GR GRADE

GWB GYPSUM WALL BOARD

STRUCTURAL ABBREVIATIONS:

SR STUD RAIL

SS STAINLESS STEEL

SSL SHORT SLOTTED (HOLES)

STD STANDARD

STIFF STIFFENER

STIFF PL STIFFENER PLATE

STIRR STIRRUP

STL STEEL

STR STRAIGHT

STRUCT STRUCTURAL

SUB SUBCONTRACTOR

SUPP SUPPORT

SW SHEAR WALL

SYM SYMMETRICAL

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

TEMP TEMPERATURE OR TEMPORARY

T TOP BARS

T/ TOP OF

THK THICK OR THICKNESS

THKND THICKENED

THRD THREADED

THRU THROUGH

TOB TOP OF BEAM

TOC TOP OF CONCRETE OR TOP OF CURB

TOF TOP OF FOOTING OR TOP OF FRAMING

TOL TOLERANCE

TOS TOP OF STEEL

TOW TOP OF WALL

TRANS TRANSVERSE

TW WEB THICKNESS

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

UT ULTRASONIC TEST

VERT VERTICAL

VIF VERIFY IN FIELD

W WEST

W/ WITH

W/C WATER TO CEMENT

W/O WITHOUT

WD WOOD

WF WIDE FLANGE

WP WORK POINT

WT WEIGHT OR WT SHAPE

WWR WELDED WIRE REINFORCING

S T R U C T U R A L G E N E R A L N O T E S

BUILDING CODE AND STANDARDS:

1. DESIGN AND CONSTRUCTION SHALL CONFORM TO 2018 INTERNATIONAL BUILDING CODE AND ALL

APPLICABLE REFERENCED STANDARDS.

GENERAL NOTES AND REQUIREMENTS:

1. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY: THE STRUCTURAL DRAWINGS ARE TO

BE USED IN CONJUNCTION WITH THE PROJECT SPECIFICATIONS, ARCHITECTURAL

DRAWINGS, AND DRAWINGS PREPARED BY OTHER DISCIPLINES.

2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY AND COORDINATE THE

INFORMATION AND DIMENSIONS SHOWN IN THE CONTRACT DOCUMENTS PRIOR TO

PROCEEDING WITH CONSTRUCTION. WHERE CONFLICTS OR DISCREPANCIES ARE FOUND

WITHIN THE CONTRACT DOCUMENTS, THE MOST STRINGENT REQUIREMENT SHALL BE

ASSUMED TO GOVERN. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES OR

CONFLICTS TO THE ARCHITECT OR ENGINEER.

3. COORDINATION BETWEEN TRADES (INCLUDING DIMENSIONS AND LOCATIONS OF OPENINGS

AND INSERTS) IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.

4. THE CONTRACTOR IS RESPONSIBLE TO VERIFY SITE CONDITIONS, INCLUDING DIMENSIONS, CONDITIONS, AND ELEVATIONS OF GRADE, AND LOCATION, DEPTH, AND EXTENTS OF

UTILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION.

5. THE STRUCTURAL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE ARCHITECTURAL

DRAWINGS. THE STRUCTURAL DRAWINGS INDICATE LOCATIONS OF PRIMARY STRUCTURAL

ELEMENTS ONLY. ADDITIONAL INFORMATION REQUIRED FOR LAYOUT AND DETAILING MAY

REQUIRE DIMENSIONAL INFORMATION SHOWN IN THE ARCHITECTURAL DRAWINGS.

6. THESE DRAWINGS SHOW THE COMPLETED STRUCTURE, NOT THE MEANS AND METHODS

NECESSARY FOR ITS CONSTRUCTION. MEANS AND METHODS ARE THE SOLE RESPONSIBILITY

OF THE CONTRACTOR, AND INCLUDE, BUT ARE NOT LIMITED TO:

A. STABILITY OF THE STRUCTURE DURING CONSTRUCTION, INCLUDING TEMPORARY

SHORING OR BRACING OF THE STRUCTURE TO RESIST LOADS DURING CONSTRUCTION

B. USE OR EVALUATION OF EQUIPMENT OR PROCEDURES DURING CONSTRUCTION

C. SEQUENCING OF CONSTRUCTION

D. FORMWORK AND REQUIRED BRACING

E. JOB SITE SAFETY AND ADHERENCE TO ALL SAFETY STANDARDS

7. TEMPORARY LOADS ON THE STRUCTURE, INCLUDING CONSTRUCTION EQUIPMENT,

PERSONNEL, AND STAGING LOADS, SHALL NOT EXCEED THE DESIGN LIVE LOAD OF THE

AFFECTED AREA. WHERE THESE LOADS WILL EXCEED THE DESIGN LIVE LOAD, THE

CONTRACTOR IS RESPONSIBLE TO PROVIDE SHORING TO SUPPORT THE CONSTRUCTION

LOADS.

8. SITE VISITS AND STRUCTURAL OBSERVATIONS ARE PERFORMED TO CONFORM GENERAL

CONFORMANCE WITH THE CONTRACT DOCUMENTS AND WILL NOT PROVIDE REVIEW OR

APPROVAL OF THE CONTRACTOR’S MEANS AND METHODS.

9. WHERE DETAILS, NOTES, OR SHEETS ARE NOTED AS “TYP” OR “TYPICAL”, THEY ARE TO BE

APPLIED THROUGHOUT THE PROJECT UNLESS NOTED OTHERWISE. TYPICAL DETAILS MAY

NOT BE INDICATED AT ALL LOCATIONS THEY OCCUR, AND MAY NOT BE INDICATED AT ALL.