This is a product specification document for the LEDway Series LED street light manufactured by Cree Lighting, a company of IDEAL INDUSTRIES. The document provides comprehensive technical specifications for a line of LED street lighting fixtures designed for roadway, parking lot, walkway, and general area applications. The LEDway Series is available in multiple configurations including Type II Medium (2M), Type II Short (2S), Type III Medium (3M), Type IV Medium (4M), and Type V Medium (5M) distributions, with LED counts ranging from 20 to 120 units. The luminaires feature all-aluminum housing construction with Colorfast DeltaGuard finish available in black, bronze, and silver. Standard voltage options include 120-277V or 347-480V, 50/60Hz input with Class 1 drivers and power factors exceeding 0.9 at full load. The fixtures support two drive current options of 525mA and 700mA, with optional 0-10V dimming capabilities and NEMA photocell receptacles.

The document includes detailed electrical data showing system wattage ranging from 35 watts (02 LED count at 525mA, 120-277V) to 274 watts (12 LED count at 700mA, 347-480V), with corresponding current ratings at various voltage levels. Initial delivered lumens range from 2,905 to 24,416 depending on LED count and drive current configuration. The fixtures are cULus listed, suitable for wet locations, and meet CALTrans 611 vibration testing, ANSI C136.31-2001 standards, IEEE/ANSI surge protection standards, and Buy American requirements within ARRA. Photometric testing is performed to IES LM-79-08 standards with published lumen maintenance data calculated per IES TM-21. The product includes a 10-year limited warranty on both the luminaire and Colorfast DeltaGuard finish. Multiple mounting options are available including horizontal tenon mounts, square internal mounts for 4-inch poles, round external mounts for 2.375-inch poles, wall mount brackets, and direct arm pole adapters. Accessories include bird spikes, shorting caps, and external backlight shields for various LED count ranges. The luminaire was assembled in the U.S. of U.S. and imported parts.

View the file

Other files

File Type Posted
request-for-quote-230000000174.docx DOCX document
RFQ 230000000174_Amendment 1 Description.docx DOCX document
Valmont Structrues DS330.pdf PDF
Cree Edge for US23 at Geddes.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US: creelighting.com (800) 236-6800 Canada: creelighting-canada.com (800) 473-1234

Rev. Date: V5 06/24/2020

LEDway® Series LEDway® LED Street Light

Ordering Information Example: STR-LWY-2M-HT-02-E-UL-SV-700

STR-LWY HT E

Product Optic Mounting

LED

Count (x10)

Series Voltage Color Options*

Drive Current Options

STR-LWY 2M

Type II Medium 2S Type II Short 3M Type III Medium 4M Type IV Medium 5M Type V Medium

HT

Horizontal Tenon

E UL

Universal 120-277V

UH

Universal 347-480V

BK

Black

BZ

Bronze

SV

Silver

525mA 700mA

DIM 0-10V Dimming

- Control by others

- Refer to Dimming spec sheet for details

- Can't exceed specified drive current

R NEMA® Photocell Receptacle

- 3-pin receptacle per ANSI C136.10

- Intended for downlight applications with maximum 45˚ tilt

- Requires photocell or shorting cap (by others)

UTL Utility

- Includes exterior wattage label that reflects watts for the drive current selected. The ability to exceed selected drive current will be disabled

40K 4000K Color Temperature

- Minimum 70 CRI

- Color temperature per luminaire

TRL Amber Turtle Friendly LEDs

- Available only with 350mA only

- Available only with 40, 60, 100, 120 LED counts

- Lumen multiplier from 5700K, 525mA : 0.29 (350mA)

- Power multiplier from 525mA: 0.50

- 600nm dominant wavelength

- Additional shielding (by others) may be required for Florida

Fish and Wildlife Conservation Commission compliance

* Light engine portion of extrusion is not painted and will remain natural aluminum regardless of color selection

Product Description Luminaire housing is all aluminum construction. Standard luminaire utilizes terminal block for power input suitable for #2-#14 AWG wire. Luminaire is designed to mount on a 2" (51mm) IP, 2.375" (60mm) O.D. horizontal tenon and/or a 1.25" (32mm) IP, 1.66" (42mm) O.D. horizontal tenon (minimum 8" [203mm] in length) and is adjustable +/- 5° to allow for luminaire leveling (two axis T-level included).

Applications: Roadway, parking lots, walkways and general area spaces

Accessories

Field-Installed

Bird Spikes for Light Engine

XA-BRDSPK30

- 20-30 LED

XA-BRDSPK60

- 40-60 LED

XA-BRDSPK90

- 70-90 LED

XA-BRDSPK120

- 100-120 LED

Bird Spikes for Housing

XA-BRDSPKHSG

Shorting Cap

XA-XSLSHRT

External Backlight Shield

XA-XSLBLS30

- 20-30 LED

XA-XSLBLS60

- 40-60 LED

XA-XSLBLS90

- 70-90 LED

XA-XSLBLS120

- 100-120 LED

Patented NanoOptic® Product Technology

Assembled in the U.S.A. of U.S. and imported parts

CRI: Minimum 70 CRI

CCT: 4000K (+/- 300K), 5700K (+/- 500K) standard

Limited Warranty†: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish

Performance Summary

LED Count (x10) Dim. "A" Weight

02 17.5" (443mm) 13.0 lbs. (5.9kg)

03 17.5" (443mm) 13.5 lbs. (6.1kg)

04 22.0" (559mm) 16.5 lbs. (7.5kg)

05 22.0" (559mm) 17.0 lbs. (7.7kg)

06 22.0" (559mm) 17.5 lbs. (7.9kg)

07 26.8" (681mm) 22.0 lbs. (10.0kg)

08 26.8" (681mm) 22.5 lbs. (10.2kg)

09 26.8" (681mm) 22.5 lbs. (10.2kg)

10 33.1" (842mm) 27.5 lbs. (12.5kg)

11 33.1" (842mm) 28.0 lbs. (12.7kg)

12 33.1" (842mm) 28.0 lbs. (12.7kg)

10.6" (269mm)

4.7" (121mm )

Light Engine

Cover Latches

(tool-less entry)

Housing By Others

“A”

† See http://creelighting.com/warranty for warranty terms https://www.creelighting.com/ https://www.creelighting-canada.com/ https://www.creelink.com/exLink.asp?36618400OW67Z45I51708400 https://www.creelink.com/exLink.asp?36618400OW67Z45I51708400 https://www.creelighting.com/warranty

Product Specifications

CONSTRUCTION & MATERIALS

• Housing is all aluminum construction

• Terminal block for power input suitable for #2-#14 AWG wire

• HT Mount is designed to mount on a 2" (51mm) IP, 2.375" (60mm) O.D.

horizontal tenon and/or a 1.25" (32mm) IP, 1.66" (42mm) O.D. horizontal tenon (minimum 8" [203mm] in length) and is adjustable +/- 5˚ to allow for luminaire leveling (two axis T-level included)

• Exclusive Colorfast DeltaGuard® finish features an E-Coat epoxy primer with an ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Black, bronze, and silver are available

• Weight: See Dimensions and Weight chart on page 1

ELECTRICAL SYSTEM

• Input Voltage: 120-277V or 347-480V, 50/60Hz, Class 1 drivers

• Power Factor: > 0.9 at full load

• Total Harmonic Distortion: < 20% at full load

• Quick disconnect harness suitable for mate and break under load provided on power feed to driver for ease of maintenance

• Integral 10kV surge suppression protection standard

• To address inrush current, slow blow fuse or type C/D breaker should be used

• 10V Source Current: 20-60 LED: 0.15mA; 80-120 LED: 0.30mA

REGULATORY & VOLUNTARY QUALIFICATIONS

• cULus Listed

• Suitable for wet locations

• Meets CALTrans 611 Vibration testing and GR-63-CORE Section 4.4.1/5.4.2 Earthquake Zone 4

• Certified to ANSI C136.31-2001, 3G bridge and overpass vibration standards

• ANSI C136.2 10kV surge protection, tested in accordance with IEEE/ANSI C62.41.2

• Luminaire and finish are endurance tested to withstand 5,000 hours of elevated ambient salt fog as defined in ASTM Standard B 117

• Meets Buy American requirements within ARRA

• Meets FCC Part 15, Subpart B, Class A limits for conducted and radiated emissions

• CA RESIDENTS WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov

Electrical Data*

LED

Count (x10)

System Watts 120-277V

System Watts 347-480V

Total Current (A)

120V 208V 240V 277V 347V 480V

525mA

02 35 39 0.30 0.18 0.16 0.15 0.12 0.10

03 53 55 0.45 0.26 0.23 0.21 0.16 0.13

04 66 71 0.56 0.33 0.29 0.26 0.21 0.16

05 86 87 0.72 0.42 0.37 0.33 0.25 0.19

06 100 103 0.84 0.49 0.43 0.38 0.30 0.22

07 120 124 1.01 0.60 0.54 0.49 0.37 0.28

08 139 140 1.17 0.69 0.62 0.56 0.41 0.31

09 149 156 1.26 0.74 0.66 0.59 0.46 0.34

10 167 172 1.41 0.83 0.73 0.65 0.50 0.38

11 182 188 1.54 0.89 0.79 0.70 0.55 0.41

12 197 204 1.67 0.96 0.85 0.75 0.59 0.44

700mA

02 47 51 0.39 0.23 0.21 0.19 0.15 0.12

03 70 73 0.59 0.34 0.30 0.27 0.21 0.16

04 91 93 0.77 0.45 0.39 0.35 0.27 0.20

05 113 115 0.96 0.55 0.48 0.43 0.33 0.25

06 134 135 1.13 0.65 0.57 0.50 0.39 0.29

07 163 165 1.37 0.80 0.71 0.63 0.48 0.36

08 182 186 1.54 0.90 0.79 0.70 0.54 0.40

09 203 207 1.72 0.99 0.87 0.78 0.60 0.45

10 227 229 1.92 1.11 0.97 0.86 0.67 0.49

11 248 250 2.10 1.21 1.05 0.93 0.73 0.53

12 267 274 2.26 1.30 1.13 1.00 0.80 0.58

* Electrical data at 25˚C (77˚F). Actual wattage may differ by +/- 10% when operating between 120-277V or 347-480V +/- 10%

LEDway® LED Street Light

LEDway® Ambient Adjusted Lumen Maintenance1

Ambient CCT Initial

LMF

25K hr Reported2

LMF

50K hr Reported2

LMF

75K hr Estimated3

LMF

100K hr Estimated3

LMF

5˚C (41˚F) 30K/40K/50K/57K 1.04 1.01 0.99 0.98 0.96

TRL 1.06 1.06 1.06 1.06 1.06

10˚C (50˚F) 30K/40K/50K/57K 1.03 1.00 0.98 0.97 0.95

TRL 1.04 1.04 1.04 1.04 1.04

15˚C (59˚F) 30K/40K/50K/57K 1.02 0.99 0.97 0.96 0.94

TRL 1.03 1.03 1.03 1.03 1.03

20˚C (68˚F) 30K/40K/50K/57K 1.01 0.98 0.96 0.95 0.93

TRL 1.01 1.01 1.01 1.01 1.01

25˚C (77˚F) 30K/40K/50K/57K 1.00 0.97 0.95 0.94 0.92

TRL 1.00 1.00 1.00 1.00 1.00

1 Lumen maintenance values at 25˚C (77˚F) are calculated per IES TM-21 based on IES LM-80 report data for the LED package and in-situ luminaire testing. Luminaire ambient temperature factors (LATF) have been applied to all lumen maintenance factors. Please refer to the Temperature Zone Reference Document for outdoor average nighttime ambient conditions.

2 In accordance with IES TM-21, Reported values represent interpolated values based on time durations that are up to 6x the tested duration in the IES LM-80 report for the LED.

3 Estimated values are calculated and represent time durations that exceed the 6x test duration of the LED.

https://www.creelighting.com/ https://www.creelighting-canada.com/ https://www.p65warnings.ca.gov https://www.creelink.com/exLink.asp?28941892OJ75F58I45607275

Photometry All published luminaire photometric testing performed to IES LM-79-08 standards. To obtain an IES file specific to your project consult: http://creelighting.com/products/ outdoor/street-and-roadway/ledway-series

LEDway® LED Street Light

* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:

https://www.ies.org/wp-content/uploads/2017/03/TM-15-11BUGRatingsAddendum.pdf.

2M

CESTL Test Report #: 2015-0025

STR-LWY-2M-**-06-E-UL-700-40K

Initial Delivered Lumens: 10,706

STR-LWY-2M-**-03-E-UL-700-40K

Mounting Height: 25' (7.6m) A.F.G.

Initial Delivered Lumens: 5,688 Initial FC at grade

Type II Medium Distribution

LED Count (x10)

4000K 5700K

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

525mA

02 3,064 B1 U0 G1 3,182 B1 U0 G1

03 4,550 B1 U0 G1 4,725 B1 U0 G1

04 6,079 B2 U0 G2 6,313 B2 U0 G2

05 7,549 B2 U0 G2 7,839 B2 U0 G2

06 9,000 B2 U0 G2 9,346 B2 U0 G2

07 10,532 B2 U0 G2 10,937 B2 U0 G2

08 11,982 B3 U0 G3 12,443 B3 U0 G3

09 13,419 B3 U0 G3 13,935 B3 U0 G3

10 14,994 B3 U0 G3 15,571 B3 U0 G3

11 16,440 B3 U0 G3 17,072 B3 U0 G3

12 17,880 B3 U0 G3 18,568 B3 U0 G3

700mA

02 3,830 B1 U0 G1 3,977 B1 U0 G1

03 5,688 B2 U0 G2 5,907 B2 U0 G2

04 7,598 B2 U0 G2 7,891 B2 U0 G2

05 9,436 B2 U0 G2 9,799 B2 U0 G2

06 11,250 B3 U0 G3 11,683 B3 U0 G3

07 13,165 B3 U0 G3 13,671 B3 U0 G3

08 14,978 B3 U0 G3 15,554 B3 U0 G3

09 16,774 B3 U0 G3 17,419 B3 U0 G3

10 18,742 B3 U0 G3 19,463 B3 U0 G3

11 20,550 B3 U0 G3 21,340 B3 U0 G3

12 22,351 B3 U0 G3 23,210 B3 U0 G3

120˚120˚

90˚ 90˚

60˚60˚

30˚ 30º

150˚ 150˚

Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower.

CURB LINE

80'

20'

20'

40'

6.1

0m

6.1

12.2

40'60' 20' 0' 20' 40' 60'

12.218.3 6.1 0m 6.1 12.2 18.3

80'

24.4 24.4

0'

40' 12.2

30.5 30.5

100' 100'

18.3

18.360'

60'

Position of vertical plane of maximum candlepower.

.5 .2 .1

75˚ https://www.creelighting.com/ https://www.creelighting-canada.com/ https://www.creelighting.com/products/outdoor/street-and-roadway/ledway-series

120˚120˚

90˚ 90˚

60˚60˚

30˚ 30º

150˚ 150˚

Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower.

CURB LINE

0m6.1 18.312.2

18.3

18.3

0m0'

6.120'

6.120'

60'

12.240'

12.240'

60'

40'

18.3

60' 20'

12.2

40'

6.1

20'0' 60'

24.4

80'

24.4

80'

1 .5 .2 .1

Position of vertical plane of maximum candlepower.

35˚

Type II Short Distribution

LED Count (x10)

4000K 5700K

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

525mA

02 3,263 B1 U0 G1 3,388 B1 U0 G1

03 4,846 B2 U0 G2 5,032 B2 U0 G2

04 6,473 B2 U0 G2 6,722 B2 U0 G2

05 8,039 B2 U0 G2 8,348 B2 U0 G2

06 9,585 B3 U0 G3 9,953 B3 U0 G3

07 11,216 B3 U0 G3 11,647 B3 U0 G3

08 12,760 B3 U0 G3 13,251 B3 U0 G3

09 14,290 B3 U0 G3 14,840 B3 U0 G3

10 15,967 B3 U0 G3 16,582 B3 U0 G3

11 17,508 B3 U0 G3 18,181 B3 U0 G3

12 19,042 B3 U0 G3 19,774 B3 U0 G3

700mA

02 4,079 B1 U0 G1 4,235 B1 U0 G1

03 6,057 B2 U0 G2 6,290 B2 U0 G2

04 8,092 B2 U0 G2 8,403 B2 U0 G2

05 10,048 B3 U0 G3 10,435 B3 U0 G3

06 11,981 B3 U0 G3 12,442 B3 U0 G3

07 14,020 B3 U0 G3 14,559 B3 U0 G3

08 15,950 B3 U0 G3 16,564 B3 U0 G3

09 17,863 B3 U0 G3 18,550 B3 U0 G3

10 19,959 B3 U0 G3 20,727 B3 U0 G3

11 21,884 B3 U0 G3 22,726 B3 U0 G3

12 23,802 B3 U0 G3 24,717 B4 U0 G4

LEDway® LED Street Light

Photometry All published luminaire photometric testing performed to IES LM-79-08 standards. To obtain an IES file specific to your project consult: http://creelighting.com/products/ outdoor/street-and-roadway/ledway-series

* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:

https://www.ies.org/wp-content/uploads/2017/03/TM-15-11BUGRatingsAddendum.pdf.

2S

STR-LWY-2S-**-03-E-UL-700

Mounting Height: 25' (7.6m) A.F.G.

Initial Delivered Lumens: 6,290 Initial FC at grade

CESTL Test Report #: 2013-0072

STR-LWY-2S-**-06-E-UL-700-40K

Initial Delivered Lumens: 12,087 https://www.creelighting.com/ https://www.creelighting-canada.com/

Photometry All published luminaire photometric testing performed to IES LM-79-08 standards. To obtain an IES file specific to your project consult: http://creelighting.com/products/ outdoor/street-and-roadway/ledway-series

LEDway® LED Street Light

* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:

https://www.ies.org/wp-content/uploads/2017/03/TM-15-11BUGRatingsAddendum.pdf.

3M

STR-LWY-3M-**-03-E-UL-700

Mounting Height: 25' (7.6m) A.F.G.

Initial Delivered Lumens: 5,600 Initial FC at grade

CESTL Test Report #: 2013-0068

STR-LWY-3M-**-06-E-UL-700-40K

Initial Delivered Lumens: 10,430

Type III Medium Distribution

LED Count (x10)

4000K 5700K

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

525mA

02 2,905 B1 U0 G1 3,016 B1 U0 G1

03 4,314 B1 U0 G1 4,480 B1 U0 G1

04 5,763 B2 U0 G2 5,985 B2 U0 G2

05 7,156 B2 U0 G2 7,432 B2 U0 G2

06 8,533 B2 U0 G2 8,861 B2 U0 G2

07 9,985 B3 U0 G3 10,369 B3 U0 G3

08 11,360 B3 U0 G3 11,797 B3 U0 G3

09 12,722 B3 U0 G3 13,211 B3 U0 G3

10 14,215 B3 U0 G3 14,762 B3 U0 G3

11 15,586 B3 U0 G3 16,185 B3 U0 G3

12 16,952 B3 U0 G3 17,604 B3 U0 G3

700mA

02 3,631 B1 U0 G1 3,771 B1 U0 G1

03 5,392 B2 U0 G2 5,600 B2 U0 G2

04 7,204 B2 U0 G2 7,481 B2 U0 G2

05 8,945 B2 U0 G2 9,290 B3 U0 G3

06 10,666 B3 U0 G3 11,076 B3 U0 G3

07 12,481 B3 U0 G3 12,961 B3 U0 G3

08 14,200 B3 U0 G3 14,746 B3 U0 G3

09 15,902 B3 U0 G3 16,514 B3 U0 G3

10 17,769 B3 U0 G3 18,452 B3 U0 G3

11 19,483 B3 U0 G3 20,232 B3 U0 G3

12 21,190 B3 U0 G3 22,004 B3 U0 G3

120˚120˚

90˚ 90˚

60˚60˚

30˚ 30º

150˚ 150˚

Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower.

0m6.1 18.312.2

18.3

18.3

0m0'

6.120'

6.120'

60'

24.480'

24.480'

12.240'

12.240'

60'

40'

18.3

60' 20'

12.2

40'

6.1

20'0' 60'

24.4

80'

24.4

80'

.5 .2 .1

Position of vertical plane of maximum candlepower.

0˚ https://www.creelighting.com/ https://www.creelighting-canada.com/

120˚120˚

90˚ 90˚

60˚60˚

30˚

150˚ 150˚

Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower.

80' 80'

20'

20'

40'

40'

6.1

0m

6.1

12.2

12.2

40'60' 20' 0' 20' 40' 60'

12.218.3 6.1 0m 6.1 12.2 18.3

80'

24.4 24.4

0' .2 .1

18.3

18.3

24.4

60'

60'

Position of vertical plane of maximum candlepower.

.5

45˚

CURB LINE

LEDway® LED Street Light

Photometry All published luminaire photometric testing performed to IES LM-79-08 standards. To obtain an IES file specific to your project consult: http://creelighting.com/products/ outdoor/street-and-roadway/ledway-series

* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:

https://www.ies.org/wp-content/uploads/2017/03/TM-15-11BUGRatingsAddendum.pdf.

4M

STR-LWY-4M-**-03-E-UL-700

Mounting Height: 25' (7.6m) A.F.G.

Initial Delivered Lumens: 5,907 Initial FC at grade

CESTL Test Report #: 2013-0028

STR-LWY-4M-**-06-E-UL-700-40K

Initial Delivered Lumens: 11,036

Type IV Medium Distribution

LED Count (x10)

4000K 5700K

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

525mA

02 3,064 B1 U0 G1 3,182 B1 U0 G1

03 4,550 B2 U0 G1 4,725 B2 U0 G1

04 6,079 B2 U0 G1 6,313 B2 U0 G1

05 7,549 B2 U0 G2 7,839 B2 U0 G2

06 9,000 B2 U0 G2 9,346 B2 U0 G2

07 10,532 B2 U0 G2 10,937 B2 U0 G2

08 11,982 B3 U0 G2 12,443 B3 U0 G2

09 13,419 B3 U0 G3 13,935 B3 U0 G3

10 14,994 B3 U0 G3 15,571 B3 U0 G3

11 16,440 B3 U0 G3 17,072 B3 U0 G3

12 17,880 B3 U0 G3 18,568 B3 U0 G3

700mA

02 3,830 B1 U0 G1 3,977 B1 U0 G1

03 5,688 B2 U0 G1 5,907 B2 U0 G1

04 7,598 B2 U0 G2 7,891 B2 U0 G2

05 9,436 B2 U0 G2 9,799 B2 U0 G2

06 11,250 B2 U0 G2 11,683 B3 U0 G2

07 13,165 B3 U0 G3 13,671 B3 U0 G3

08 14,978 B3 U0 G3 15,554 B3 U0 G3

09 16,774 B3 U0 G3 17,419 B3 U0 G3

10 18,742 B3 U0 G3 19,463 B3 U0 G3

11 20,550 B3 U0 G3 21,340 B3 U0 G3

12 22,351 B3 U0 G3 23,210 B4 U0 G3 https://www.creelighting.com/ https://www.creelighting-canada.com/

Photometry All published luminaire photometric testing performed to IES LM-79-08 standards. To obtain an IES file specific to your project consult: http://creelighting.com/products/ outdoor/street-and-roadway/ledway-series

LEDway® LED Street Light

* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit:

https://www.ies.org/wp-content/uploads/2017/03/TM-15-11BUGRatingsAddendum.pdf.

5M

STR-LWY-5M-**-03-E-UL-700

Mounting Height: 25' (7.6m) A.F.G.

Initial Delivered Lumens: 6,214 Initial FC at grade

CESTL Test Report #: 2013-0019

STR-LWY-5M-**-06-E-UL-700-40K

Initial Delivered Lumens: 11,633

120˚120˚

90˚ 90˚

60˚60˚

30˚ 30º

150˚ 150˚

Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower.

CURB LINE

0m6.1 18.312.2

18.3

18.3

0m0'

6.120'

6.120'

60'

24.480'

24.480'

12.240'

12.240'

60'

40'

18.3

60' 20'

12.2

40'

6.1

20'0' 60'

24.4

80'

24.4

80'

.5 .2 .1

Position of vertical plane of maximum candlepower.

0˚ Type V Medium Distribution

LED Count (x10)

4000K 5700K

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

Initial Delivered Lumens*

BUG

Ratings** Per TM-15-11

525mA

02 3,223 B2 U0 G1 3,347 B2 U0 G1

03 4,787 B3 U0 G1 4,971 B3 U0 G1

04 6,395 B3 U0 G2 6,640 B3 U0 G2

05 7,941 B3 U0 G2 8,246 B3 U0 G2

06 9,468 B3 U0 G2 9,832 B3 U0 G2

07 11,079 B4 U0 G2 11,505 B4 U0 G2

08 12,605 B4 U0 G2 13,089 B4 U0 G2

09 14,116 B4 U0 G3 14,659 B4 U0 G3

10 15,773 B4 U0 G3 16,379 B4 U0 G3

11 17,294 B4 U0 G3 17,959 B4 U0 G3

12 18,809 B4 U0 G3 19,533 B4 U0 G3

700mA

02 4,029 B2 U0 G1 4,184 B2 U0 G1

03 5,983 B3 U0 G2 6,214 B3 U0 G2

04 7,993 B3 U0 G2 8,301 B3 U0 G2

05 9,926 B3 U0 G2 10,308 B3 U0 G2

06 11,835 B4 U0 G2 12,290 B4 U0 G2

07 13,849 B4 U0 G3 14,381 B4 U0 G3

08 15,756 B4 U0 G3 16,362 B4 U0 G3

09 17,645 B4 U0 G3 18,324 B4 U0 G3

10 19,716 B4 U0 G3 20,474 B4 U0 G3

11 21,618 B4 U0 G3 22,449 B5 U0 G3

12 23,512 B5 U0 G3 24,416 B5 U0 G3 https://www.creelighting.com/ https://www.creelighting-canada.com/

© 2020 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content is subject to change. Patent www.creelighting.com/patents. Cree® and the Cree logo are registered trademarks of Cree, Inc. LEDway®, NanoOptic® and Colorfast DeltaGuard® are registered trademarks of Cree Lighting, A company of IDEAL INDUSTRIES. The UL logo is a registered trademark of UL LLC. NEMA® is a registered trademark of the National Electrical Manufacturers Association.

US: creelighting.com (800) 236-6800 Canada: creelighting-canada.com (800) 473-1234

Luminaire EPA

Horizontal Tenon Mount

LED Count (x10) 1 Luminaire Single 2 @ 90˚ 2 @ 180˚ 3 @ 90˚ 3 @ 120˚ 4 @ 90˚

Horizontal Tenon Mount Round External Mount / Square Internal Mount Horizontal Tenons with Luminaires

PT-1H/PD-1H4

PT-2H(90)/

PD-2H4(90)

PT-2H(180)/

PD-2H4(180)

PT-3H(90)/

PD-3H4(90)

PT-3H(120)

PT-4H(90)/

PD-4H4(90)

20-30 0.57 0.79 1.02 1.35 1.53 1.38 1.94

40-60 0.69 0.91 1.19 1.59 1.774 1.59 2.18

70-90 0.71 0.93 1.27 1.75 1.93 0.71 2.34

100-120 0.80 1.04 1.38 1.86 2.04 1.82 2.45

LEDway® LED Street Light

Tenons and Brackets* (must specify color)

Square Internal Mount Horizontal Tenons (Aluminum)

- Mounts to 4" (102mm) square aluminum or steel poles

PD-1H4 – SinglePD-3H4(90) – 90˚ Triple
PD-2H4(90) – 90˚ TwinPD-4H4(90) – 90˚ Quad

PD-2H4(180) – 180˚ Twin

Wall Mount Brackets

- Mounts to wall or roof WM-2L – Standard

Round External Mount Horizontal Tenons (Aluminum)

- Mounts to 2.375" (60mm) O.D. round aluminum or steel poles or tenons

PT-1H – SinglePT-3H(90) – 90˚ Triple
PT-2H(90) – 90˚ TwinPT-4H(90) – 90˚ Quad

PT-2H(180) – 180˚ Twin

Direct Arm Pole Adaptor Bracket

- Mounts to 3-6" (76-152mm) round or square aluminum or steel poles

XA-TMDA8

Tenon EPA

Part Number EPA

PD Series Tenons 0.09

PT Series Tenons 0.10

WM-2L 0.13

XA-TMDA8 0.07

* Refer to the Bracket and Tenons spec sheet for more details https://www.creelighting.com/ https://www.creelighting-canada.com/ https://www.creelink.com/exLink.asp?22244076OT35W98I39157056

LED Count 4:
Voltage 4:
Color Options 4:
Drive Current 4:
Options :
Optic 3:
Notes:

File details come from the government source that posted it. Updated .