LBUD Los Cerritos Channel At Bixby Hill Retaining Wall Repair Project WD-11-26.pdf
PDF 9 MB Posted
- Solicitation number
- UD-26-359
- Issued by
- Los Angeles County, California
About this file
Los Cerrittos Channel at Bixby Hill Retaining Wall Repair
This is a construction project plan document prepared by DRP Engineering, Inc. for the Long Beach Public Utilities Department in Long Beach, California. The project involves the repair of a retaining wall at the Los Cerrittos Channel at Bixby Hill. The construction drawings, dated August 2026 and designated WD-11-26, were approved by Thomas Bekele, Senior Director of Engineering, on August 27, 2026, and submitted by project manager Saik-Choon Poh, R.C.E. No. 69223. The project encompasses demolition of existing structures, removal of trees and vegetation, and construction of a new retaining wall system supported by concrete grade beams with cast-in-drilled hole (CIDH) piles. The work also includes installation of a free-standing CMU wall on the retaining side, waterproofing systems with hot mopped asphalt coating, and a drainage system with perforated pipe and filter fabric. Special inspection requirements are mandated for concrete construction, soil materials, deep foundation elements, and masonry work in accordance with California Building Code provisions.
The structural design utilizes concrete with a minimum compressive strength of 4,000 psi for foundations and other structural elements, with reinforcing steel meeting ASTM A615 Grade 60 specifications. The project is designated as Seismic Design Category D with Risk Category II classification. Concrete cover requirements, reinforcement development lengths, and lap splice specifications are detailed in accordance with ACI 318-19 standards. A drainage blanket of granular soil shall be installed behind the wall with a perforated 4-inch diameter pipe at the base, and weep holes are required at maximum 16-foot intervals. Construction must comply with California Cal-OSHA excavation requirements, maintain dust control measures, protect all existing underground utilities, and implement best management practices for erosion control and construction activity pollution prevention as outlined in the City of Long Beach Information Bulletins IB-038 and IB-039.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING / FILE NUMBER:
MC-5264
FAMIS PROJECT:
WASXX
XXXXXXXXX
FAMIS PROJECT:
MUNIS PROJECT: MUNIS PROJECT:
WASXX
XXXXXXXXX
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
SEE SHEETSCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE 05/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGAN
GENERAL MANAGER
LONG BEACH PUBLIC UTILITIES
DEPARTMENT
MA
SCP 05/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
LOS CERRITOS CHANNEL AT BIXBY HILL
RETAINING WALL REPAIR
LONG BEACH PUBLIC UTILITIES DEPARTMENT
LONG BEACH, CALIFORNIA
PLANS FOR THE CONSTRUCTION OF
GENERAL MANAGER
B. ANATOLE FALAGAN
THOMAS BEKELE - SENIOR DIRECTOR OF ENGINEERING DATE
LONG BEACH PUBLIC UTILITIES DEPARTMENT
APPROVED BY:
LOS CERRITOS CHANNEL AT BIXBY
HILL RETAINING WALL REPAIR
G-001
GENERAL
TITLE SHEET
WD-11-26
AUGUST 2026
SUBMITTED BY:
DRP Engineering, INC.
S A
I K
- C H O O N P O
HS
A
I K
- C H O O N P O
H
PROJECT MANAGER:
SAIK-CHOON POH R.C.E. 69223 DATE
08/25/2026 wadepew Image wadepew Image wadepew Text Box 8-26-26 wadepew Text Box 8-26-26 wadepew Image wadepew Text Box 8-27-26
LONG
BEACH
ROAD CENTERLINE AND STREET NAME
RIGHT-OF-WAY
LOT
CURB
EXISTING STORM DRAIN LINE, SDMH, AND SD CATCH BASIN
DETAIL NUMBER
DETAIL SHEET
SHEET BOUNDARY
PROPOSED RETAINING WALL
EXISTING RETAINING WALL
FLOW LINE
EQUIPMENT ACCESS ROUTE
VICINITY MAP
SHEET INDEX
SHEET NO.
1 G-001 TITLE SHEET
2 G-002 SHEET INDEX, VICINITY MAP, GENERAL NOTES
ABBREVIATIONS, LEGENDS & SYMBOLS AND
PUBLIC AGENCIES
3 D-001 DEMO PLAN
4 D-002 SECTIONS AND DETAILS
5 S-001 STRUCTURAL GENERAL NOTES
6 S-002 STRUCTURAL GENERAL NOTES
7 S-003 STRUCTURAL GENERAL NOTES
8 S-101 TYPICAL REBAR & S.O.G
9 S-102 TYPICAL DETAILS
10 S-201 SITE PLAN
DESCRIPTION
G-002
NTS
GENERAL NOTES
1. CONTRACTOR AGREES THAT IN ACCORDANCE WITH
GENERALLY ACCEPTED CONSTRUCTION PRACTICES,
CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF THE CONSTRUCTION OF THE
PROJECT, INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING
HOURS AND CONTRACTOR FURTHER AGREES TO DEFEND,
INDEMNIFY AND HOLD HARMLESS THE CITY, ITS EMPLOYEES,
AGENTS AND DRP ENGINEERING FROM ANY AND ALL
LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE
PERFORMANCE OF WORK ON THIS PROJECT.
2. ALL WORK SHALL BE IN ACCORDANCE WITH THE LATEST
EDITION OF THE STANDARD SPECIFICATION FOR PUBLIC
WORKS CONSTRUCTION, AND IN ACCORDANCE WITH THE
CITY OF LONG BEACH AMENDMENTS TO STANDARD
SPECIFICATION FOR PUBLIC WORKS CONSTRUCTION (LATEST
EDITION), THE CITY OF LONG BEACH PUBLIC UTILITIES DEPARTMENT
WATER AND SEWER STANDARDS, ALL APPLICABLE AMERICAN
WATER WORKS ASSOCIATION (AWWA) STANDARDS, DEPARTMENT
OF DRINKING WATER REQUIREMENTS, PERMIT REQUIREMENTS,
AND IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS,
ALL TO THE SATISFACTION OF THE LONG BEACH PUBLIC UTILITIES
3. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPORT
DISCREPANCIES IN PLANS AND/OR FIELD CONDITIONS
IMMEDIATELY TO THE DESIGN ENGINEER FOR RESOLUTION
PRIOR TO CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR
DISCREPANCIES NOT SO REPORTED AND RESOLVED.
4. THE CONTRACTOR SHALL PERFORM A UTILITY SEARCH FOR
THE PROJECT AREAS. THE CONTRACTOR IS REQUIRED TO
TAKE ALL PRECAUTIONARY MEASURES TO PROTECT THE
UTILITIES SHOWN, AND ANY OTHER LINES OR STRUCTURES
NOT SHOWN ON THESE PLANS, AND IS RESPONSIBLE FOR
ANY DAMAGE TO THESE LINES OR STRUCTURES. IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY EACH
RESPECTIVE UTILITY AND UNDERGROUND SERVICE ALERT
OF SOUTHERN CALIFORNIA, 811 TO DETERMINE THE EXACT
FIELD LOCATION OF UTILITIES WHICH MAY CONFLICT WITH
THE WORK.
5. THE CONSTRUCTION DRAWINGS SHOW THE GENERAL
LOCATION AND DEPTH OF UNDERGROUND UTILITIES BASED
ON THE BEST INFORMATION AVAILABLE TO LBUD. LBUD
DOES NOT GUARANTEE THE LOCATION OR DEPTH OF
UNDERGROUND UTILITIES AND IT SHALL BE THE
CONTRACTOR'S RESPONSIBILITY TO FIND THE EXACT
LOCATION AND DEPTH OF UNDERGROUND UTILITIES IN
AREAS REQUIRING EXCAVATION.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO
EXISTING UTILITIES, PAVEMENT, CURBS, TRAFFIC STRIPING,
MARKER AND MARKINGS, TRAFFIC SIGNAL DETECTOR LOOPS,
STREET LIGHT CONDUITS, STRUCTURES, TREES, AND
IRRIGATION SYSTEMS AS A RESULT OF HIS OPERATION AND
WILL BE REQUIRED TO REPAIR OR REPLACE SAME TO THE
SATISFACTION OF AND AS DIRECTED BY, LONG BEACH PUBLIC
UTILITY DEPARTMENT, THE ENGINEER, UTILITY COMPANY OR
PROPERTY OWNER.
7. THE CONTRACTOR SHALL HAVE COPIES OF THE PLANS
THE PROJECT ON THE PROJECT SITE AT ALL TIMES, AND
HE SHALL BE FAMILIAR WITH ALL APPLICABLE STANDARDS
8. SANITARY FACILITIES SHALL BE MAINTAINED ON THE SITE.
9. THE CONTRACTOR SHALL COOPERATE WITH CONTRACTORS
PERFORMING OTHER CONSTRUCTION WORK IN AREAS
ADJACENT TO THE PROJECT SITE.
10. THE CONTRACTOR SHALL MAINTAIN DUST CONTROL AT ALL
TIMES.
11. THE WALLS AND FACE OF ALL EXCAVATION FIVE (5) FEET OR
GREATER IN DEPTH SHALL BE EFFECTIVELY GUARDED BY A
SHORING SYSTEM, SLOPING OF THE GROUND, OR OTHER
EQUIVALENT MEANS. TRENCHES OR EXCAVATION LESS THAN
FIVE (5) FEET IN DEPTH SHALL BE GUARDED WHEN
EXAMINATION BY A REGISTERED CIVIL ENGINEER IN THE
STATE OF CALIFORNIA HAS INDICATED THAT HAZARDOUS
GROUND MOVEMENT MAY BE EXPECTED. THE CONTRACTOR
SHALL OBTAIN A PERMIT TO PERFORM EXCAVATION OR
TRENCH WORK AS DESCRIBED FROM CAL-OSHA.
DEPARTMENT.
DRAWING / FILE NUMBER:
MC-5264
FAMIS PROJECT:
WASXX
XXXXXXXXX
FAMIS PROJECT:
MUNIS PROJECT: MUNIS PROJECT:
WASXX
XXXXXXXXX
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
SEE SHEETSCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE 05/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGAN
GENERAL MANAGER
LONG BEACH PUBLIC UTILITIES
DEPARTMENT
MA
SCP 05/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
LOS CERRITOS CHANNEL AT BIXBY HILL
RETAINING WALL REPAIR
LOCATION MAP
SYMBOLS
SURVEY NOTE
NOTE TO CONTRACTOR
PUBLIC AGENCIES & UTILITIES
CITY OF LAKEWOOD
333 W. OCEAN BLVD., 9TH FLOOR
PUBLIC WORKS - TRAFFIC/ TRANSPORTATION
LONG BEACH, CA 90802
(562) 570-6331
(714) 796-9932
SANTA ANA, CA 92705
ERIKA BALLESTEROS
1444 E. MCFADDEN AVE.
LAKEWOOD, CA 90713
5812 ARBOR RD.
(714) -889-0272
SC EDISON
JASON WEN
KIM GURULE
RAY ROUNDTREE
ZACHARY HOEPFNER
(562) 570-2525
LONG BEACH, CA 90808
COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS
CHUCK QUERIDO
3205 LAKEWOOD BLVD.
CITY OF LONG BEACH - FIRE DEPARTMENT
HUNTINGTON BEACH, CA 92467
7352 SLATER AVE.
(714) 375-6760
1601 SAN FRANCISCO AVE.
CITY OF LONG BEACH - TRAFFIC SIGNALS / LIGHTS
FRONTIER COMMUNICATIONS
(720) 305-0400
P.O. BOX 4998
(562) 908-4288 X1205
WHITTIER, CA 90601
(562) 570-2300
LONG BEACH, CA 90806
LONG BEACH UTILITIES DEPARTMENT
LONG BEACH, CA 90807
1800 E WARDLOW ROAD
2400 E SPRING ST.
(562) 570-2766
LONG BEACH, CA 90813
MARC WRIGHT
LONG BEACH GAS & OIL (562) 570-2036
333 W. OCEAN BLVD.
PUBLIC WORKS-ENGINEERING
LONG BEACH, CA 90802
(562) 570-5055
(626) 458-5100
ALHAMBRA, CA 91803
CITY LIGHT & POWER INC.
LONG BEACH, CA 90806
2961 REDONDO AVE.
900 S. FREMONT AVE.
7337 CENTRAL AVENUE
CHARTER COMMUNICATIONS
RIVERSIDE, CA 92504
(951) 406-1601
SANITATION DISTRICTS OF LOS ANGELES COUNTY
1963 E. ANAHEIM ST.
LONG BEACH TRANSIT
LONG BEACH, CA 90813
(562) 599-8570
FACILITIES MAPPING
GIS SPECIALIST
ENGINEERING COORDINATOR
MANAGER OF ENGINEERING
5900 CHERRY AVE., 2ND FLOOR
PLAINS ALL AMERICAN PIPELINE
LONG BEACH, CA 90802
MIKE EIDMAN
(562) 221-6777
LAND ANALYST
1005 D STREET
QUESTAR/ DOMINION ENERGY
ROCK SPRINGS, WY 82901
COLE WRIGHT
(307) 352-7115
OPERATIONS ENGINEER
1919 STATE COLLEGE BLVD.
SOCAL GAS
ANAHEIM, CA 92806
ERNIE GONZALES
(714) 634-3121
PLANNING ASSOCIATE
9400 OAKDALE AVE.
SOCAL GAS TRANSMISSION
CHATSWORTH, CA 91311
(818) 701-4546
6 CENTERPOINTE DR., STE 500
TESORO
LA PALMA, CA 90623
CYNTHIA SMITH
(714) 880-1687
RIGHT OF WAY DEPARTMENT
6 CENTERPOINTE DR., STE 500
BOEING
LA PALMA, CA 90623
JOHN E WILLIAMS
(562) 797-2847
6 CENTERPOINTE DR., STE 500
ZAYO FNA ABOVE NET
LA PALMA, CA 90623
THOMAS BRUINIERS
(213) 283-3601
WESTERN REGION OSP PROJECT MANAGER
(949) 864-0296
IRVINE, CA 92614
CALEB KING
2698 WHITE RD.
MPOWER
100 W. ALONDRA BLVD., RM. A202
AT&T
(714) 666-9219
TULSA, OK 74103
CENTURYLINK, INC
LITTLETON, CO 80120
700 W. MINERAL AVE.
100 S. CINCINNATI AVE., STE 1200
(310) 515-4029
GARDENA, CA 90248
CARL RANDOLPH
LEVEL 3 COMMUNICATIONS (918) 547-0007
BUSINESS ANALYST
GEORGE MCELVAIN
ENGINEERING ADMINISTRATOR
MARK DENNING SR.
OSP ENGINEER
MANAGER OF PUBLIC SERVICE
12. JETTING SHALL NOT BE ALLOWED UNDER ANY CIRCUMSTANCES.
ALL ELEVATIONS, DIMENSIONS, AND COORDINATES WITHIN THIS PLAN SET ARE BASED ON AS-BUILTS, FIELD MEASUREMENTS, AND OTHER AVAILABLE INFORMATION TO THE BEST OF THE ENGINEER'S KNOWLEDGE. NO FORMAL TOPOGRAPHIC OR BOUNDARY SURVEY WAS PERFORMED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY AS NECESSARY TO PROVIDE SURVEY TO CONFIRM DIMENSIONS, ELEVATIONS, AND LOCATIONS TO TIE ALL IMPROVEMENTS TO LOCAL BENCHMARKS. DISCREPANCIES
SHALL BE BROUGHT TO THE ATTENTION OF LBUD.
THE EXISTENCE AND LOCATIONS OF ALL UNDERGROUND UTILITIES (UTILITIES, PIPES, STRUCTURES, ETC.)
SHOWN ON THE PLANS (MAIN LINES ONLY - NO SERVICE LATERALS) ARE APPROXIMATE AND WERE ASCERTAINED BY A REVIEW OF RECORDS PROVIDED BY UTILITY COMPANIES. NEITHER THE OWNER NOR THE ENGINEER ASSUMES ANY RESPONSIBILITY FOR UTILITIES NOT SHOWN OR NOT IN THE LOCATION SHOWN. THE CONTRACTOR SHALL DETERMINE THE DEPTH AND LOCATION OF UNDERGROUND FACILITIES PRIOR TO THE START OF CONSTRUCTION AND SHALL BE REQUIRED TO TAKE ANY PRECAUTIONARY MEASURES TO PROTECT ALL UTILITIES SHOWN AND/OR ANY OTHER UNDERGROUND UTILITY NOT OF
RECORD OR NOT SHOWN ON THE PLANS.
SHEET INDEX, VICINITY MAP
& GENERAL NOTES
DEMOLITION NOTES
NOTES
DEFERRED SUBMITTAL LIST:
wadepew Image wadepew Image wadepew Text Box 8-26-26 wadepew Text Box 8-26-26
AutoCAD SHX Text
BAY
AutoCAD SHX Text
MONICA
AutoCAD SHX Text
MARINA
AutoCAD SHX Text
DEL REY
AutoCAD SHX Text
FWY.
AutoCAD SHX Text
BLVD.
AutoCAD SHX Text
DA
AutoCAD SHX Text
IEN
AutoCAD SHX Text
HAC
AutoCAD SHX Text
SAN
AutoCAD SHX Text
GABRIEL
AutoCAD SHX Text
ROSEMEAD
AutoCAD SHX Text
BLVD.
AutoCAD SHX Text
LAKEWOOD
AutoCAD SHX Text
FWY.
AutoCAD SHX Text
DIEGO
AutoCAD SHX Text
SAN
AutoCAD SHX Text
BEACH
AutoCAD SHX Text
LONG
AutoCAD SHX Text
HARBOR
AutoCAD SHX Text
TERMINAL
AutoCAD SHX Text
ISLAND FWY.
AutoCAD SHX Text
BIXBY
AutoCAD SHX Text
SLOUGH
AutoCAD SHX Text
ROLLING
AutoCAD SHX Text
HILLS
AutoCAD SHX Text
HY.
AutoCAD SHX Text
COAST
AutoCAD SHX Text
PACIFIC
AutoCAD SHX Text
FWY.
AutoCAD SHX Text
ARTESIA
AutoCAD SHX Text
BLVD.
AutoCAD SHX Text
ARTESIA
AutoCAD SHX Text
BLVD.
AutoCAD SHX Text
SEPULVEDA
AutoCAD SHX Text
BAY
AutoCAD SHX Text
PEDRO
AutoCAD SHX Text
SAN
AutoCAD SHX Text
BLVD.
AutoCAD SHX Text
LINCOLN
AutoCAD SHX Text
SAN
AutoCAD SHX Text
EL
AutoCAD SHX Text
SEGUNDO
AutoCAD SHX Text
ARTESIA
AutoCAD SHX Text
INGLEWOOD
AutoCAD SHX Text
HAWTHORNE
AutoCAD SHX Text
LAWNDALE
AutoCAD SHX Text
GARDENA
AutoCAD SHX Text
CARSON
AutoCAD SHX Text
HERMOSA BEACH
AutoCAD SHX Text
REDONDO
AutoCAD SHX Text
BEACH
AutoCAD SHX Text
TORRANCE
AutoCAD SHX Text
LOMITA
AutoCAD SHX Text
PALOS VERDES
AutoCAD SHX Text
ESTATES
AutoCAD SHX Text
ROLLING
AutoCAD SHX Text
HILLS ESTATES
AutoCAD SHX Text
SIGNAL
AutoCAD SHX Text
HILL
AutoCAD SHX Text
BELL
AutoCAD SHX Text
HUNTINGTON PARK
AutoCAD SHX Text
CUDAHY
AutoCAD SHX Text
BELL
AutoCAD SHX Text
GARDENS
AutoCAD SHX Text
BLVD.
AutoCAD SHX Text
FIRESTONE
AutoCAD SHX Text
MANCHESTER BLVD.
AutoCAD SHX Text
DOWNEY
AutoCAD SHX Text
PARAMOUNT
AutoCAD SHX Text
NORWALK
AutoCAD SHX Text
BELLFLOWER
AutoCAD SHX Text
LAKEWOOD
AutoCAD SHX Text
SOUTH GATE
AutoCAD SHX Text
LYNWOOD
AutoCAD SHX Text
LA MIRADA
AutoCAD SHX Text
SANTA FE
AutoCAD SHX Text
SPRINGS
AutoCAD SHX Text
PICO RIVERA
AutoCAD SHX Text
WHITTIER
AutoCAD SHX Text
CERRITOS
AutoCAD SHX Text
HAWAIIAN
AutoCAD SHX Text
GARDENS
AutoCAD SHX Text
COMPTON
AutoCAD SHX Text
ORANGE
AutoCAD SHX Text
MANHATTAN BEACH
AutoCAD SHX Text
SDMH
AutoCAD SHX Text
SURREY DRIVE
AutoCAD SHX Text
CB
AutoCAD SHX Text
12" SD
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
SHEET OF SHEETS
AutoCAD SHX Text
APP'D.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text
RANCHO
AutoCAD SHX Text
E SURREY DR
AutoCAD SHX Text
E SADDLE DR
AutoCAD SHX Text
PROJECT LOCATION 6490 E SURREY DR
AutoCAD SHX Text N
AutoCAD SHX Text
DR
AutoCAD SHX Text
BIXBY TERRACE DR
AutoCAD SHX Text
E 7TH ST
AutoCAD SHX Text
LOS CERRITOS CHANNEL
AutoCAD SHX Text
LOS CERRITOS CHANNEL
AutoCAD SHX Text
CHARLES F KETTERING ELEMENTARY
AutoCAD SHX Text
550 SLIVERA AVE
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text PREPARE TEMPORARY SHORING PLANS, SIGNED AND SEALED BY A STRUCTURAL ENGINEER, AND INSTALL TEMPORARY SHORING IN ACCORDANCE WITH THE APPROVED PLANS. REFER TO THE TEMPORARY SHORING NOTES FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX Text SAW CUT EXISTING WALLS AT DIMENSIONS SHOWN. REMOVE AND DISPOSE OF EXISTING WALL SECTIONS SHOWN ON THE PLANS AND DETAIL C ON SHEET D-002.
AutoCAD SHX Text REMOVE AND DISPOSE OF TREE. VERIFY WITH LBUD THAT A BIRD SURVEY HAS BEEN COMPLETED AND THAT THE TREE IS APPROVED FOR REMOVAL.
AutoCAD SHX Text REMOVE AND DISPOSE OF THE INTERFERING PORTION OF THE EXISTING FOUNDATION AT DIMENSIONS SHOWN ON DETAIL C ON SHEET D-002.
AutoCAD SHX Text
1. ALL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS ALL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE REVIEWED BY THE PROJECT ENGINEER OF RECORD WITH A STATEMENT INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO THE DESIGN OF THE PROJECT.
AutoCAD SHX Text
1. TEMPORARY SHORING PLANS (SEE NOTE 1)TEMPORARY SHORING PLANS (SEE NOTE 1)
G-002
MC-5264
FAMIS PROJECT:
WASXX
XXXXXXXXX
FAMIS PROJECT:
MUNIS PROJECT: MUNIS PROJECT:
WASXX
XXXXXXXXX
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
SCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE 05/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGAN
GENERAL MANAGER
LONG BEACH PUBLIC UTILITIES
DEPARTMENT
MA
SCP 05/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
LOS CERRITOS CHANNEL AT BIXBY HILL
RETAINING WALL REPAIR
2 A
Community Development Department Building and Safety Bureau
411 W. Ocean Boulevard, 2nd Floor, Long Beach, CA 90802 562.570.PMIT (7648) | longbeach.gov/lbcd
INFORMATION BULLETIN
IB-039
Eff: 01-07-2013 Rev: 02-03-2025
Erosion Control Best Management Practices
Long Beach has two drainage systems – the sewers and the storm drains. The storm drain system was designed to prevent flooding by carrying excess rainwater away from city streets out to the ocean. Because the system contains no filters, it now serves the unintended function of carrying urban pollution straight to the ocean. This Information Bulletin will describe how to prevent ocean pollution from “stormwater” or “urban runoff.”
Best management practices, such as handling, storing and disposing of materials, properly prevents construction site pollutants from entering the storm drains.
GENERAL BUSINESS PRACTICES
ESCl SCHEDULING Purpose: To reduce the discharge of pollutants from construction sites by sequencing the construction project to reduce the amount and duration of soil exposure.
Schedule major grading operations during dry months.
Practice erosion and sediment control year-round.
Schedule project to disturb only small portions of the site at any one time.
Close and stabilize open trenches as soon as possible.
ESC21 DUST CONTROL
Purpose: To reduce the discharge of pollutants from construction sites by using dust control measures to stabilize soil from wind erosion, and reduce dust generated by construction activities.
Stabilize exposed soils by using vegetation, watering/sprinkling, and stone gravel layering.
Identify and stabilize primary access to site.
Direct traffic to stabilized areas within the project.
Street sweeping of adjacent public right-of-way.
ESC24 STABILIZED CONSTRUCTION ENTRANCE
Purpose: To reduce the discharge of pollutants from construction sites by reducing the amount of sediment, dust, and mud tracked off-site from construction traffic.
Stabilize construction entrance with aggregate underlain with filter cloth.
Construct on level ground where possible.
Provide ample turning radius as part of entrance.
Length should be 50-foot minimum, and width 30-foot minimum.
ESC5O SILT FENCE
Purpose: To reduce the discharge of pollutants from construction sites utilizing a silt fence that detains sediment-laden water, promoting sedimentation behind the fence.
City of Long Beach Erosion Control Best Management Practices Information Bulletin IB-039
Use in areas where sheet flow occurs.
Turn ends of fence uphill.
Select filter fabric that retains 85% of soil.
Silt fence, which is made of filter fabric, should be entrenched and attached to supporting poles.
ESC52 SANDBAG BARRIER
Purpose: To reduce the discharge of pollutants from construction sites by stacking sandbags along a level contour creating a barrier that detains sediment-laden water promoting sedimentation. Use along the perimeter of the site and around catch basin inlets to storm drains to create a temporary sediment trap.
Use sandbags large enough to withstand flooding.
Inspect sandbags after each rain.
Remove sediment behind sandbags.
Reshape or replace damaged sandbags.
ESC56 SEDIMENT BASIN
Purpose: To discharge the pollutants from construction sites by retaining runoff sufficiently to allow excessive sediment to settle.
Should be located where failure of embankment would not cause life/property damage.
Inspect weekly and after each rain.
Remove sediments by using filters if necessary, when basin is half-full.
Line basin if ground water is within 10 feet of bottom.
To request this information in an alternative format or to request a reasonable accommodation, please contact the Community Development Department at longbeach.gov/lbcd and 562.570.3807. A minimum of three business days is requested to ensure availability; attempts will be made to accommodate requests with shorter notice.
Community Development Department Building and Safety Bureau
411 W. Ocean Boulevard, 2nd Floor, Long Beach, CA 90802 562.570.PMIT (7648) | longbeach.gov/lbcd
INFORMATION BULLETIN
IB-038
Eff: 01-07-2013 Rev: 02-03-2025
Construction Activity Best Management Practices
Long Beach has two drainage systems – the sewers and the storm drains. The storm drain system was designed to prevent flooding by carrying excess rainwater away from city streets out to the ocean. Because the system contains no filters, it now serves the unintended function of carrying urban pollution straight to the ocean. This Information Bulletin will describe how to prevent ocean pollution from “stormwater” or “urban runoff” for residential projects.
Best management practices, such as handling, storing and disposing of materials properly prevents construction site pollutants from entering the storm drains.
GENERAL BUSINESS PRACTICES
CD4(2) WATER CONSERVATION PRACTICE
Purpose: To reduce the discharge of pollutants from construction sites by using construction water that does not cause erosion or wash materials off-site.
Standards:
Discourage washing of equipment on site.
Avoid using water to clean construction areas. Sweep paved areas where practical.
Direct construction water run-off to areas where it can soak into the ground.
Apply water for dust control moderately so run-off does not occur.
CA1O MATERIAL DELIVERY AND STORAGE
Purpose: To reduce the discharge of pollutants during the delivery and storage process by minimizing the contact of materials with run-off.
Standards:
Designate storage areas at the project site.
Prevent spills or leakage of liquid materials from contaminating soil or soaking into the ground by placing storage areas on impervious surfaces. Do not store hazardous chemicals, drums, or bagged materials directly on the ground.
Provide curbs or dikes around the perimeter of material storage areas.
Store materials indoors when available.
Minimize hazardous material storage on-site.
Keep hazardous materials in their original containers and keep them well labeled.
Keep ample supply of appropriate spill clean-up material near storage areas.
Contain and clean up any spill immediately.
CA11 MATERIAL USE
Purpose: To reduce the discharge of pollutants by properly storing and utilizing materials.
Standards:
City of Long Beach Construction Activity Best Management Practices Information Bulletin IB-038
Use materials only where and when needed to complete the construction activity.
Follow manufacturers instructions regarding the preparation, use, and disposal of materials.
Avoid exposing applied materials to rainfall and run-off unless sufficient time has allowed for them to dry.
CA12 SPILL PREVENTION AND CONTROL
Purpose: To reduce the discharge of pollutants from spills by preventing, containing and clean-up spills.
Standards:
Hold regular meetings to discuss and reinforce appropriate disposal procedures.
Use absorbent materials on small spills rather then hosing down or burying the spill.
For significant or hazardous spills that cannot be controlled by personnel in the immediate vicinity, notify local emergency response by calling 911.
CA2O SOLID WASTE MANAGEMENT
Purpose: To reduce the discharge of pollutants as a result of the creation, stockpiling and removal of litter and other construction waste.
Standards:
Collect site trash regularly, daily during rainy and windy conditions.
Keep solid materials shielded by using either a covered dumpster or other enclosed trash container that limits contact with rain, run-off, and/or scattering due to winds.
Make sure that toxic wastes and chemicals are not disposed of in dumpsters designed for construction debris.
CA21 HAZARDOUS WASTE MANAGEMENT
Purpose: To reduce the discharge of pollutants by the proper storage and disposal of waste.
Standards:
Sites with existing structures may contain waste which must be disposed of in accordance with federal, state, and local regulations which include sandblasting grit mixed with lead, cadmium, or chromium based paints and asbestos.
Major contamination, large spills, and other serious hazardous waste incidents require immediate response from specialists.
Keep liquid or semi-liquid hazardous waste in appropriate containers and under cover.
Clearly mark on all hazardous waste containers which materials are acceptable for the container.
Place hazardous waste containers in secondary containment.
Make sure that toxic wastes and chemicals are not disposed of in dumpsters designed for construction debris.
CA23 CONCRETE WASTE MANAGEMENT
Purpose: To reduce the discharge of Portland cement, concrete slurries and asphalt by implementing appropriate wash-out procedures, slurry containment, housekeeping and disposal practices.
Standards:
Do not allow slurry residue from wet coring or saw-cutting to enter storm drains.
Shovel or vacuum slurry residue and dispose in a temporary pit.
Designate areas to be used for washout of vehicles transporting concrete.
City of Long Beach Construction Activity Best Management Practices Information Bulletin IB-038
Washout areas shall have a temporary pit or berm area of sufficient volume to completely contain all liquid and waste concrete.
Once the concrete wastes are washed into the designated areas and allowed to harden, the concrete can be properly disposed.
CA3O VEHICLE AND EQUIPMENT CLEANING
Purpose: To reduce the discharge of pollutants by cleaning equipment and related activities offsite when practical.
Standards:
Clean all vehicles and equipment that regularly enter and leave the construction site.
Design wash area with a sump to allow collection and disposal of wash water.
Do not use solvents or steam to clean vehicles or equipment on site.
CA31 VEHICLE AND EQUIPMENT FUELING
Purpose: To reduce the discharge of pollutants as a result of vehicle and equipment fueling by preventing leaks and spillage.
Standards:
Locate fueling areas on a paved surface where practical.
Protect fueling areas with berms and/or dikes to prevent run-on, run-off, and to contain spills.
Absorbent materials shall be used on small spills instead of hosing down or burying.
Keep an ample supply of spill cleanup material on the site.
CA32 VEHICLE AND EQUIPMENT MAINTENANCE
Purpose: To reduce the discharge of pollutants as a result of vehicle and equipment maintenance by conducting these activities off-site or in a designated area.
Standards:
Locate on paved surfaces where practical.
Use berms to protect maintenance areas from run-on.
Do not dump fuels and lubricants onto the ground.
Do not place used oil in a dumpster or pour into a storm drain.
n with filter cloth.
BEST MANAGEMENT PRACTICE
NOTES
wadepew Image wadepew Image wadepew Text Box 8-26-26 wadepew
8-26-26
MC-5264
FAMIS PROJECT:
WASXX
XXXXXXXXX
FAMIS PROJECT:
MUNIS PROJECT: MUNIS PROJECT:
WASXX
XXXXXXXXX
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
SEE SHEETSCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE 05/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGAN
GENERAL MANAGER
LONG BEACH PUBLIC UTILITIES
DEPARTMENT
MA
SCP 05/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
LOS CERRITOS CHANNEL AT BIXBY HILL
RETAINING WALL REPAIR
DEMOLITION PLAN
DEMOLITION NOTES
LEGEND:
D-001
PLAN VIEW
D-002 C
D -0
02A wadepew Image wadepew Image wadepew Text Box 8-26-26 wadepew Text Box 8-26-26
AutoCAD SHX Text
EXISTING RETAINING WALL (PROTECT IN PLACE)
AutoCAD SHX Text
SHEET OF SHEETS
AutoCAD SHX Text
APP'D.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1" = 10'
AutoCAD SHX Text
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text
6490 SURREY DR
AutoCAD SHX Text
6489 SURREY DR
AutoCAD SHX Text
LONG BEACH BIKEWAY RTE 10
AutoCAD SHX Text
LOS CERRITOS CHANNEL
AutoCAD SHX Text
EXISTING POOL (PROTECT IN PLACE)
AutoCAD SHX Text
EXISTING POOL EQUIPMENT (TO BE REMOVED)
AutoCAD SHX Text
REMOVE EXISTING TREE
AutoCAD SHX Text
LACFCD ROW
AutoCAD SHX Text
EXISTING TREE (PROTECT IN PLACE)
AutoCAD SHX Text
REMOVE EXISTING TREE
AutoCAD SHX Text %%P20'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text %%P58'-5"
AutoCAD SHX Text
REMOVE EXISTING TREES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REMOVE EXISTING TREES
AutoCAD SHX Text
AutoCAD SHX Text
MAXIMUM TEMPORARY SHORING LIMIT DEMOLITION LIMIT RIPRAP
AutoCAD SHX Text 6'-5"
AutoCAD SHX Text 1'-6"
AutoCAD SHX Text
2'MIN
AutoCAD SHX Text
EXISTING POOL (TO BE PROTECTED)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HOUSE OUTLINE (TYPICAL)
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING BIKE PATH (PROTECT IN PLACE)
AutoCAD SHX Text
PROPOSED EQUIPMENT ACCESS
AutoCAD SHX Text PREPARE TEMPORARY SHORING PLANS, SIGNED AND SEALED BY A STRUCTURAL ENGINEER, AND INSTALL TEMPORARY SHORING IN ACCORDANCE WITH THE APPROVED PLANS. REFER TO THE TEMPORARY SHORING NOTES FOR ADDITIONAL REQUIREMENTS.
AutoCAD SHX Text SAW CUT EXISTING WALLS AT DIMENSIONS SHOWN. REMOVE AND DISPOSE OF EXISTING WALL SECTIONS SHOWN ON THE PLANS AND DETAIL C ON SHEET D-002.
AutoCAD SHX Text REMOVE AND DISPOSE OF TREE. VERIFY WITH LBUD THAT A BIRD SURVEY HAS BEEN COMPLETED AND THAT THE TREE IS APPROVED FOR REMOVAL.
AutoCAD SHX Text REMOVE AND DISPOSE OF THE INTERFERING PORTION OF THE EXISTING FOUNDATION AT DIMENSIONS SHOWN ON DETAIL C ON SHEET D-002.
AutoCAD SHX Text
EXISTING TREE (PROTECT IN PLACE)
AutoCAD SHX Text
EXISTING FOUNDATION
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING RETAINING WALL (PROTECT IN PLACE)
AutoCAD SHX Text ±5'
AutoCAD SHX Text ±5'
AutoCAD SHX Text
SCALE: 1"=10'-0"
AutoCAD SHX Text B
AutoCAD SHX Text D-002
AutoCAD SHX Text
6498 SURREY DR
PHOTO 2
WEST SIDE OF THE CHANNEL WALL AT NORTH END
DRAWING / FILE NUMBER:
MC-5264
FAMIS PROJECT:
WASXX
XXXXXXXXX
FAMIS PROJECT:
MUNIS PROJECT: MUNIS PROJECT:
WASXX
XXXXXXXXX
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
SEE SHEETSCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE 05/26
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
B. ANATOLE FALAGAN
GENERAL MANAGER
LONG BEACH PUBLIC UTILITIES
DEPARTMENT
MA
SCP 05/26
N/A
1111 Corporate Center Dr, Suite 303 Monterey Park, CA 91754
LOS CERRITOS CHANNEL AT BIXBY HILL
RETAINING WALL REPAIR
DEMOLITION PHOTOS
EXISTING RETAINING WALL SECTION
TEMPORARY SHORING NOTES:
LEGEND:
DEMOLITION NOTES
D-002
D-002 B
D-002 C
PHOTO 1
OVERALL VIEW OF THE CHANNEL WALL
D-002 A wadepew Image wadepew Image wadepew Text Box 8-26-26 wadepew Text Box 8-26-26 wadepew Image
1. DETAILS OF CONSTRUCTION NOT SHOWN SHALL BE OF SAME NATURE AS
THOSE SHOWN FOR SIMILAR CONDITIONS. REFER TO THE TYPICAL DETAIL
SHEETS FOR TYPICAL DETAILS OF CONSTRUCTION. TYPICAL DETAILS APPLY TO
ALL CONSTRUCTION UNLESS SPECIFICALLY NOTED OR SHOWN OTHERWISE.
WHERE CONDITIONS REQUIRE MODIFICATIONS OF A TYPICAL DETAIL, THE
CONTRACTOR SHALL SUBMIT MODIFIED DETAIL FOR APPROVAL BY THE
ENGINEER OF RECORD PRIOR TO FABRICATION AND INSTALLATION.
2. CONTRACTOR SHALL CONSIDER THE PROJECT SPECIFICATIONS A PART OF THE
CONTRACT DOCUMENTS. WHERE INFORMATION IS CONFLICTING, SPECIFIC
DETAILS SHALL GOVERN OVER TYPICAL DETAILS WHICH SHALL GOVERN OVER
THESE NOTES WHICH SHALL GOVERN OVER SPECIFICATIONS.
3. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST
DEMOLITION DIMENSIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE
OMITTED OR NOT CLEAR, CONTACT THE STRUCTURAL ENGINEER OF RECORD
(SEOR). ALL DIMENSIONS RELATED TO EXISTING CONDITIONS SHALL BE FIELD
VERIFIED BY THE CONTRACTOR.
4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY NOTIFY THE SEOR
OF ANY CONFLICTS BETWEEN THE STRUCTURAL DRAWINGS AND OTHER
DRAWINGS; OR EXISTING CONDITIONS NOT SHOWN OR DIFFERENT FROM
THOSE SHOWN ON DRAWINGS PRIOR TO COMMENCEMENT OF WORK. THE
CONTRACTOR IS NOT TO ORDER MATERIAL OR CONSTRUCT ANY PORTION OF
THE BUILDING THAT IS IN CONFLICT UNTIL THE CONFLICT IS RESOLVED WITH
THE AFFECTED PARTIES.
5. THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. UNLESS
OTHERWISE SHOWN THEY DO NOT INDICATE METHOD OF CONSTRUCTION. THE
CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE
CONSTRUCTION AND ALL ADJACENT PROPERTIES DURING CONSTRUCTION.
SUCH MEASURES SHALL INCLUDE BUT ARE NOT LIMITED TO BRACING, SHORING
OF LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO
THE SITE BY SEOR SHALL NOT INCLUDE OBSERVATION OF THE ABOVE ITEMS.
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT
SECTIONS OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE
OF CALIFORNIA, LATEST EDITION, AND ALL OSHA REQUIREMENTS AS THEY
APPLY TO THIS PROJECT. THE SEOR AND THE OWNER DO NOT ACCEPT ANY
RESPONSIBILITY FOR THE CONTRACTOR'S FAILURE TO COMPLY WITH THESE
REQUIREMENTS.
7. ALL WORK IS NEW (N) UNLESS INDICATED AS EXISTING (E).
8. CONSTRUCTION MATERIALS SHALL BE DISTRIBUTED WHEN PLACED ON THE
STRUCTURE SUCH THAT LOADS DO NOT EXCEED DESIGN LIVE LOADS OR
RESULT IN AN UNBALANCED CONDITION.
9. ALL BLOCK MATERIALS, DESIGN/DETAILING, AND COLOR(S) SHALL MATCH
EXISTING CONDITIONS. CONTRACTOR SHALL PROVIDE MATERIAL SAMPLES FOR
REVIEW AND APPROVAL PRIOR TO INSTALLATION.
GENERAL NOTES:
1. CODES:
ALL WORK SHALL BE IN CONFORMANCE WITH THE CALIFORNIA BUILDING
CODE (CBC) 2025 EDITION, INCLUDING ALL AMENDMENTS. ALL STANDARDS
USED SHALL BE THE LATEST VERSION APPROVED BY THE CODE
ENFORCEMENT AGENCY ON THE DATE OF THE PERMIT ISSUANCE UNLESS
SPECIFICALLY NOTED OTHERWISE.
2. WIND DESIGN INFORMATION
• RISK CATEGORY = II, Iw = 1.0
• BASIC WIND SPEED, V = 95 MPH
• EXPOSURE = C
• Kz = 0.85, Kd = 0.85, Kzt = 1.0
3. FLOOD ZONE = X
4. SEISMIC DESIGN INFORMATION (ASCE 7)
• RISK CATEGORY = II Ie = 1.0
• SITE CLASS = C
• SS = 1.536 , S1 = 0.553 SDS = 1.229 SD1 = 0.534
• SEISMIC DESIGN CATEGORY = D
STRUCTURAL DESIGN CRITERIA:
1. FIELD VERIFY ALL CONDITIONS & DIMENSIONS PRIOR TO SHOP DRAWING
PRODUCTION AND FABRICATION OF STRUCTURAL ELEMENTS.
2. WHERE ALL OTHER EXISTING CONDITIONS VARY SIGNIFICANTLY FROM THOSE
SHOWN ON THESE DRAWINGS, THE STRUCTURAL ENGINEER SHALL BE
NOTIFIED PRIOR TO CONTINUED CONSTRUCTION RELATED TO SUBJECT
CONDITIONS.
3. SHORE ALL EXISTING CONSTRUCTION AS REQUIRED.
4. SPECIAL INSPECTION IS REQUIRED FOR ALL WORK.
EXISTING CONDITIONS NOTES:
1. THE ENGINEERS ARE NOT RESPONSIBLE FOR THE LOCATIONS OF EXISTING
UNDERGROUND UTILITIES WHETHER OR NOT SHOWN ON THE DRAWINGS. THE
LOCATION OF ANY EXISTING UNDERGROUND UTILITIES SHOWN ON THE
DRAWINGS ARE APPROXIMATE. THE CONTRACTOR SHALL IMMEDIATELY
NOTIFY THE OWNER SHOULD ANY SUCH UNIDENTIFIED CONDITIONS BE
DISCOVERED.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES WHICH MAY
RESULT FROM HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ALL EXISTING
UNDERGROUND UTILITIES.
EXISTING UNDERGROUND UTILITY NOTES:
1. SEE SOIL REPORT BY:
REPORT NO.: DATED:
SOILS REPORT SHALL BE CONSIDER A PART OF THESE CONSTRUCTION
DOCUMENTS.
2.
3. THE CONTRACTOR SHALL CONFORM TO ALL RECOMMENDATIONS AND
CONDITIONS INDICATED IN THE SOIL REPORT. THE GEOTECHNICAL ENGINEER
SHALL OBSERVE ALL FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE.
4. SUBSURFACE SOIL PREPARATION:
A. ALL EXISTING UNDOCUMENTED FILL SHALL BE REMOVED AND
RECOMPACTED. ALL TOPSOILS SHALL BE REMOVED AS REQUIRED BY
THE GEOTECHNICAL ENGINEER.
B. GEOTECHNICAL ENGINEER SHALL BE RETAINED DURING THE
OVEREXCAVATION PROCESS. THE ACTUAL DEPTH OF REMOVAL WILL BE
DETERMINED DURING GRADING OPERATIONS.
C. OFFSITE FILL MATERIAL SHALL BE APPROVED BY THE GEOTECHNICAL
ENGINEER PRIOR TO PLACEMENT.
5. FOOTING ELEVATIONS ARE NOTED ON THE PLANS AND DETAILS . IN ANY CASE,
FOOTINGS SHALL BEAR ON FIRM UNDISTURBED SOIL OR ENGINEERED FILL
OR BEDROCK , IN ACCORDANCE WITH THE SOIL REPORT AND DETAILS SHOWN.
6. CONTRACTOR SHALL PROTECT ALL UTILITY LINES, ETC. ENCOUNTERED
DURING EXCAVATION AND BACKFILLING.
7. ALL TRENCHES SHALL COMPLY WITH APPLICABLE OSHA REQUIREMENTS.
8. ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED WITH NON-EXPANSIVE
SOIL BUT NOT BEHIND RETAINING WALLS BEFORE CONCRETE ATTAINS ITS
FULL DESIGN STRENGTH.
9. THE DESIGN OF ALL RETAINING WALLS INDICATED ON THESE DRAWINGS IS
BASED ON DRAINED SOILS.
10. ALL GRADING, FOUNDATION FOOTINGS, AND DRAINAGE PLANS SHALL BE
REVIEWED BY THE GEOTECHNICAL ENGINEER UPON SUBMITTAL. A CERTIFIED
LETTER BY THE GEOTECHNICAL ENGINEER IS REQUESTED STATING THAT THE
RECOMMENDATIONS CONTAINED WITHIN THE SOILS REPORT HAVE BEEN
INCORPORATED INTO THE PROJECT PLANS AND SPECIFICATIONS PRIOR TO
CONSTRUCTION.
11. PRIOR TO THE CONTRACTOR REQUESTING A BUILDING DEPARTMENT
FOUNDATION INSPECTION, THE SOILS ENGINEER SHALL ADVISE THE BUILDING
OFFICIAL IN WRITING THAT:
A. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE SOILS
REPORT.
B. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND
COMPACTED.
C. THE FOUNDATION EXCAVATIONS COMPLY WITH THE INTENT OF THE
SOILS REPORT.
FOUNDATION AND SLAB ON GRADE NOTES:
ALLOWABLE FTG VERTICAL BEARING PRESSURE
DEAD LOAD + LIVE LOAD = ......................................................................2000 PSF DEAD LOAD + LIVE LOAD + LATERAL LOAD = ......................................2600 PSF
ALLOWABLE FTG LATERAL BEARING PRESSURE IS 300 PSF PER FT OF DEPTH
ALLOWABLE FTG COEFFICIENT OF FRICTION FOR SLIDING: 0.30
NYNYO & MOORE
213038001 08/19/2025
1. THE CONTRACTOR SHALL PROVIDE FOR THE DESIGN, APPROVALS, PERMITS,
INSTALLATION AND MONITORING OF ALL TEMPORARY SHORING AND BRACING
AS REQUIRED TO SUPPORT EXISTING CONDITIONS.
2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION
OF THE CALIFORNIA CONSTRUCTION SAFETY ORDERS (CAL-OSHA).
3. TEMPORARY CUTS SHALL NOT EXCEED SLOPES RECOMMENDED IN THE SOIL
REPORT, NOR THOSE SHOWN ON THE SHORING DRAWINGS, IF REQUIRED, FOR
CONSTRUCTION OF FOUNDATIONS.
4. THE INSTALLATION OF SHORING AND EXCAVATIONS SHALL BE PERFORMED
UNDER THE CONTINUOUS INSPECTION AND APPROVAL OF THE GEOTECHNICAL
ENGINEER.
5. THE DESIGN OF THE SHORING SYSTEM SHALL BE BASED UPON
RECOMMENDATIONS CONTAINED IN THE SOIL REPORT. THE SHORING
CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ALL DATA THEREIN AND
SHALL KEEP A COPY OF THE REPORT AT THE JOB SITE AT ALL TIMES.
SHORING AND EXCAVATIONS NOTES:
1. SUBMIT DETAILED PLAN SHOWING DESIGN OF SHORING, BRACING, SLOPING,
OR OTHER PROVISIONS FOR WORKER PROTECTION FROM HAZARD OF CAVING
GROUND DURING EXCAVATION OF ANY TRENCH, PIT, OR EXCAVATION
GREATER THAN OR EQUAL TO 5’ DEEP.
2. TRENCH SHIELDS OR BOXES WILL NOT BE PERMITTED.
3. SHORING SHALL CONFORM TO REQUIREMENTS OF CAL OSHA CONSTRUCTION
SAFETY ORDERS ARTICLE 6 “EXCAVATION”.
4. SHORING PLAN WILL BE REJECTED IF:
A. PLAN IS BASED ON SUBSURFACE CONDITIONS MORE FAVORABLE THAN
THOSE SHOWN IN GEOTECHNICAL INVESTIGATION.
B. PLAN IS NOT PREPARED BY CALIFORNIA–LICENSED CIVIL OR STRUCTURAL
ENGINEER.
C. PLAN DOES NOT ADDRESS ALLOWABLE SURCHARGES LOADS.
D. PLAN MAKES USE OF HORIZONTAL STRUTTING BELOW PIPE BARREL.
E. PLAN MAKES USE OF PIPE AS A SUPPORT.
F. PLAN DOES NOT HAVE LICENSED STRUCTURAL ENGINEERS STAMPS.
5. IF SHORING PLAN VARIES FROM SHORING SYSTEM STANDARD DRAWINGS,
PLAN SHALL BE PREPARED BY CALIFORNIA–REGISTERED STRUCTURAL OR
CIVIL ENGINEER AS REQUIRED BY CAL/OSHA CONSTRUCTION SAFETY ORDERS
AND APPLICABLE LAWS.
6. SHOWING PLAN SHALL BE ENGINEERED TO ACCOMMODATE SURCHARGE ON
SIDE OF TRENCH OF AT LEAST 300PSF TO ALLOW FOR EQUIPMENT WHEEL
LOADS OR STOCKPILING OF MATERIAL. PLAN SHALL SHOW ALLOWABLE
SURCHARGE LOADS FOR NEARBY EMBANKMENTS AND STRUCTURES, FOR
SPOIL BANKS, AND FOR CONSTRUCTION EQUIPMENT AND OTHER
CONSTRUCTION LOADING. FOR ALL TRENCH CONDITIONS, SHORING PLAN
SHALL SHOW MINIMUM HORIZONTAL DISTANCES FROM SIDE OF TRENCH AT ITS
TOP TO NEAR SIDE OF SURCHARGE LOADS.
7. SHORING PLAN SHALL ALLOW FOR LATERAL GROUNDWATER PRESSURES.
8. PLAN SHALL SHOW SEQUENCE AND PROCEDURE FOR INSTALLING AND
REMOVING SHORING SYSTEM COMPONENTS.
9. SHORING PLAN SHALL SHOW AND ACCOMMODATE PROTECTION OF EXISTING
UNDERGROUND UTILITIES.
ADDITIONAL SHORING NOTES:
SCOPE OF WORK:
RETAINING WALL SUPPORTED BY GRADE BEAM
WITH CONCRETE PILES.
FREE-STANDING WALLS AT RETAINING SIDE.
R
EG
IS
T E
RE
D
PRO
FESS IONAL
ENG
I N E E R
No.
Exp. 9/30/26
S4029
Y
OU
N
G - K EUN
N A M
STATE OF CAL I F
OR
N I
A
S
T R U C T U R
A
L
F
IL
E N
A M
E M c .d w g
D
E S
IG
N
B Y
DRAWING / FILE NUMBER:
FAMIS PROJECT:
WASXX
XXXXXXXXX
FAMIS PROJECT:
MUNIS PROJECT: MUNIS PROJECT:
WASXX
XXXXXXXXX
1111 Corporate Center Dr, Suite 303
Monterey Park, CA 91754
MC-5264
SHEET OF SHEETS
DIRECTOR OF WATER/SEWER ENGINEERING
MANAGER OF ENGINEERING
APPROVED
RECOMMENDED
DEPARTMENT DATE
APP'D.BY CK'D.
CITY ENG.
VERIZON
EDISON CO.
LB ENERGY
FIRE
INPUT BY
AS-BUILT BY
POSTED GIS
CONSTRUCTED BY
GIS TILE
SPEC. NO
SECTION MAP
SERVICE ATLAS PAGE
GATE VALVES REC.
SEE SHEETSCALE
N/A
CONTRACT NO.
CHECKED BY
DESIGNED BY
DATE
DATE
CORRECTED BY
DATE
DATE
DATE
DATE
DATE
08/25
VARIOUS
DESCRIPTIONDATEREV.
DATE
DATE
GENERAL MANAGER
MA
_CDR_______ 08/25-
N/A
LOS CERRITOS CHANNEL AT BIXBY KNOWLS
RETAINING WALL REPAIR
B. ANATOLE FALAGAN
LONG BEACH UTILITIES DEPARTMENT
E N G I N E E R S I N CV C A
2401 E. Katella Ave #430
Anaheim, CA 92806
Tel. 949.679.0870
Fax. 949.679.9370
Project No.: L1083
C I V I LQuality
Service
Commitment
S T R U C T U R A L DBEMBE SBE
S-001
STRUCTURAL GENERAL NOTES
wadepew Image wadepew Image wadepew Text Box 8-26-26 wadepew
TYPICAL ABBREVIATIONS
A.B. ANCHOR BOLT
INT INTERIOR
ABV ABOVE
ADDT'L ADDITIONAL
KLF KIPS PER LINEAR FOOT
ADJ ADJACENT
KSL KIPS PER SQUARE FOOT
A.F.F. ABOVE FINISH FLOOR
KSI KIPS PER SQUARE INCH
ALT ALTERNATE
L ANGLE
ARCH ARCHITECT(URAL)
LFRS
LATERAL FORCE
BLDG BUILDING
RESISTING SYSTEM
BLK'G BLOCKING
LLH LONG LEG HORIZONTAL
BLW BELOW
LLV LONG LEG VERTICAL
BM BEAM LP LOW POINT
BN BOUNDARY NAILING LWC LIGHTWEIGHT CONCRETE
B.O. BOTTOM OF MAX MAXIMUM
BOT BOTTOM M.B. MACHINE BOLT
BRG BEARING MECH MECHANICAL
B.S.
BOTH SIDES MFR MANUFACTURER
BTWN BETWEEN
MIN MINIMUM
C
CAMBER OR
MTL METAL
C.I.P. CAST IN PLACE
(N) NEW
CJ
CONTROL
NS NEAR SIDE OR NON-SHRINK
CONSTRUCTION JOINT
NTS NOT TO SCALE
CL CENTERLINE
NWC NORMAL WEIGHT CONCRETE
CLR CLEAR O.C. ON CENTER
CMU CONCRETE MASONRY UNIT O.F. OUTSIDE FACE
COL COLUMN OH OPPOSITE HAND
CONC CONCRETE
OPM
OSHPD PRE APPROVAL OF
CONN CONNECTION
PDF POWDER DRIVEN FASTENER
CONT CONTINUOUS
PJ PANEL JOIST
CP COMPLETE PENETRATION
PL PLATE
CSK COUNTERSINK
PLC(S) PLACE(S)
CTR(D) CENTER(ED)
PLF POUND PER LINEAR FOOT
DB BAR OR BOLT DIAMETER
PLYWD PLYWOOD
DBL DOUBLE
PREFAB PREFABRICATED
DC DEMAND CRITICAL
PSF POUND PER SQUARE FOOT
DEMO DEMOLITION
PSI POUND PER SQUARE INCH
DET DETAIL
PT
PRESSURE TREATED OR
DIA DIAMETER
POST TENSION
DIAG DIAGONAL
QTY QUNATITY
DIM DIMENSION
RAD, R RADIUS
DO DITTO
REF REFERENCE
DWG DRAWING
REINF REINFORCING
(E) EXISITNG
REQ'D REQUIRED
EA EACH
SB SILL BOLT
E.F. EACH FACE
SC SAW CUT OR SLIP CRITICAL
EJ EXPANSION JOIST
SCHED SCHEDULE
EMBED EMBEDMENT
SEOR
STRUCTURAL ENGINEER
ELEC ELECTRICAL
ON RECORD
ELEV ELEVATION
SHT'G SHEATHING
EN EDGE NAILING
SIM SIMILAR
E.O. EDGE OF
SLRS
SEISMIC LOAD
EOR ENGINEER OF RECORD
RESISTING SYSTEM
EQ EQUAL
SMS SHEET METAL SCREW
EQUIP EQUIPMENT
SN SILL NAIL
E.S. EACH SIDE/ EDGE SCREW
S.O.G. SLAB ON GRADE
E.W. EACH WAY
SQ SQUARE
EXP EXPANSION
SS STAINLESS STEEL
EXT EXTERIOR
STD STANDARD
FIN FINISH
STAGG. STAGGERED
FLR FLOOR
SITFF STIFFENER
FN FIELD NAILING
STL STEEL
FND FOUNDATION
STRUCT STRUCTURAL
F.O. FACE OF
T&B TOP AND BOTTOM
FS
FAR SIDE OR FIELD SCREW
THK THICK
FRM'G FRAMING
T.O. TOP OF
FT FOOT OR FEET
T.O.M. TOP OF MASONRY
FTG FOOTING
T.O.S. TOP OF STEEL
G GIRDER
TYP TYPICAL
GA GAUGE
U.N.O. UNLESS NOTED OTHERWISE
GALV GALVANIZED
VERT VERTICAL
H.A.B. HEADED ANCHOR BOLT
W/ WITH
HD HOLDOWN
W/O WITHOUT
HDR HEADER
WF WIDE FLANGE/WALL FOOTING
HGR HANGER
WLD WELDED
HK HOOK
WO WHERE OCCURS
HORIZ HORIZONTAL
WP WORK POINT
HP HIGH POINT
WT WEIGHT
HS HIGH STRENGTH
WWF WELDED WIRE FABRIC
HSS
HOLLOW STRUCTURAL
SECTION
REFERENCE ELEVATION OR
HT HEIGHT
WORK POINT
IN INCH
PENE PENETRATION
OPN'G OPENING
MANUFACTURER’S
CERTIFICATION
A.T.R. ALL THREADED ROD
LBS POUND
WWM WELDED WIRE MESH
GB GRADE BEAM
LONG. LONGITUDINAL
SF SPREAD FOOTING
TRANS. TRANSVERSE
LLBB LONG LEG BACK TO BACK
JST JOIST
PERF PERFORATED
NOM. NOMINAL
OD OUTSIDE DIAMETER
RJ ROOF JOIST
FJ FLOOR JOIST
C-CHANNEL
DIST DISTANCE
W.S. WELDED STUD
FN HT FINISH HEIGHT
⌀ DIAMETER
FINISH SURFACE
R.O. ROUGH OPENING
S.A.D. SEE ARCHITECUTRAL DRAWINGS
BOUNDARY SCREW
1. REINFORCING GRADES FOR CONCRETE OR MASONRY:
• ALL BARS EXCEPT THOSE TO BE WELDED ASTM A615, GRADE 60
• TIES AND STIRRUPS ASTM A615, GRADE 60
• ALL BARS TO BE WELDED ASTM A706, GRADE 60
2. MAINTAIN MINIMUM CONCRETE COVER FROM FACE OF CONCRETE TO EDGE OF
ALL REINFORCEMENT AS FOLLOWS (U.N.O.) AND PROVIDE THE LARGEST
COVER REQUIRED FOR ALL APPLICABLE CONDITIONS. WHERE #3 STIRRUPS
OR TIES ARE USED, ENSURE THAT THE COVER FOR LONGITUDINAL BARS IS
ADEQUATE.
(SEE PLAN/ SECTION FOR CONCRETE W/ FIRE RATING.)
CONDITION COVER
CONCRETE POURED AGAINST EARTH 3"
CONCRETE POURED IN FORMS AND
EXPOSED TO WEATHER OR EARTH
#6 BARS AND LARGER 2"
#5 BARS AND SMALLER 1 1/2"
INTERIOR COLUMNS AND BEAMS 1 1/2"
INTERIOR WALL FACES AND RAISED SLABS 1"
STRUCTURAL SLABS ON GRADE
FROM BOTTOM OF SLAB 2"
FROM TOP OF SLAB 1 1/2"
OTHER CONCRETE NOT EXPOSED TO 1"
WEATHER OR EARTH FOR #11 BARS
AND SMALLER
3. ALL DOWELS AND OTHER HARDWARE TO BE SET IN CONCRETE SHALL BE TIED
IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO WET SETTING, STABBING,
RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED
DURING PLACEMENT OF CONCRETE.
4. BEND REINFORCING BARS COLD.
5. STEEL SHALL BE KEPT CLEAN AND FREE OF RUST.
6. ALL BARS SHALL BE MARKED SO THEIR IDENTIFICATION CAN BE MADE WHEN
THE FINAL IN PLACE INSPECTION IS MADE.
7. CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC
COATED WHEN RESTING ON EXPOSED SURFACES.
REINFORCING STEEL NOTES:
1. CONCRETE SHALL BE MIXED, PLACED AND CURED IN ACCORDANCE WITH ACI
318, 2019 EDITION, AND PROJECT SPECIFICATIONS.
2. CONCRETE SHALL NOT BE DROPPED THROUGH REINFORCING STEEL (AS IN
WALLS) SO AS TO CAUSE SEGREGATION OF AGGREGATES. IN SUCH CASES,
HOPPERS AND VERTICAL CHUTES OR TRUNKS SHALL BE USED. CHUTES OR
TRUNKS SHALL BE OF VARIABLE LENGTHS SO THAT FREE UNCONFINED FALL
OF CONCRETE SHALL NOT EXCEED SIX FEET. A SUFFICIENT NUMBER OF
CHUTES OR TRUNKS SHALL BE USED TO ENSURE THE CONCRETE IS KEPT
LEVEL AT ALL TIMES.
3. STRUCTURAL CONCRETE SHALL MEET THE FOLLOWING DESIGN CRITERIA:
LOCATION f'c CONC MAX AGGR. MAX W/C MAX CEMENT TYPE SIZE RATIO SLUMPa TYPE
FOUNDATIONS, 4000 psi NWC 1 1/2" 0.45 4" V
ALL OTHER 4000 psi NWC 1" 0.50 6" V
STRUCTUAL
CONC. NOT NOTED
a. SLUMP MEASURED PRIOR TO SUPERPLASTICIZER, WHERE OCCURS.
4. CONCRETE MIX DESIGN AND TESTING SHALL MEET THE REQUIREMENTS OF
THE BUILDING CODE, AND SPECIFICATIONS. ALL CONCRETE MIXES SHALL BE
DESIGNED BY A RECOGNIZED TESTING LAB STAMPED AND SEALED BY A
LICENSED CALIFORNIA CIVIL ENGINEER AND SUBMITTED TO THE SEOR FOR
REVIEW PRIOR TO CONCRETE PLACEMENT. STRUCTURAL CONCRETE MIXES
SHALL CONSIST OF 5 SACK MINIMUM U.N.O.
5. AGGREGATES IN NORMAL WEIGHT CONCRETE SHALL CONFORM TO ASTM C-33
(HARDROCK).
6. COMPRESSIVE STRENGTH TEST REPORTS SHALL BE SUBMITTED TO THE
BUILDING DEPARTMENT AND THE SEOR.
7. PORTLAND CEMENT SHALL BE AS NOTED ABOVE FOR ALL CONCRETE
CONFORMING TO ASTM C150, LOW ALKALI. MILL TESTS WITH CERTIFICATES OF
COMPLIANCE SHALL BE SUBMITTED.
8. FLY ASH OR OTHER POZZOLANS CONFORMING TO ASTM C618 CLASS N OR F
MAY BE USED AS A PARTIAL SUBSTITUTION FOR PORTLAND CEMENT UP TO A
MAXIMUM OF 15% TOTAL CEMENTITIOUS MATERIALS BY WEIGHT IF THE MIX
DESIGN IS PROPORTIONED PER ACI 318, SECTION 26.4.3.
9. CONCRETE MIXING OPERATIONS, ETC. SHALL CONFORM TO ASTM C94.
10. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER
USED IN MIX SHALL BE CLEAN AND POTABLE.
11. PRIOR TO ERECTING ANY ELEMENTS THAT LOAD THE FOUNDATION,
CONCRETE MUST REACH AN UNCONFINED COMPRESSION STRENGTH OF 2000
PSI MINIMUM AS DETERMINED BY TESTING OR PREVIOUSLY DOCUMENTED
DATA FOR THE MIX DESIGN USED UNDER SIMILAR CONDITIONS, AND MUST BE
ALLOWED TO CURE FOR A MINIMUM OF 3 DAYS.
12. MAINTAIN CONCRETE ABOVE 50 DEGREES FAHRENHEIT AND IN A MOIST
CONDITION FOR A MINIMUM OF 7 DAYS AFTER PLACEMENT UNLESS
OTHERWISE ACCEPTED BY SEOR.
13. CORING IS NOT PERMITTED WITHOUT PRIOR APPROVAL BY THE SEOR.
14. EXPOSED CORNERS OF SLABS, BEAMS, WALLS, COLUMNS, ETC. SHALL BE
FORMED WITH 3/4" CHAMFER, U.N.O.
STRUCTURAL CONCRETE NOTES:
1. MASONRY UNITS SHALL DEVELOP THE FOLLOWING MINIMUM 28 DAY PRISM
COMPRESSIVE STRENGTHS IN ACCORDANCE WITH THE BUILDING CODE:
MORTAR GROUT STRENGTH
LOCATION: f'm PER ASTM C270 PER ASTM C476
• SITE WALLS 2000 PSI TYPE M OR S 2000 PSI
2. CONCRETE BLOCK SHALL CONFORM TO ASTM C90 MEDIUM WEIGHT.
CLAY BRICK LOCK SHALL CONFORM TO ASTM C652
3. VERTICAL REINFORCING SHALL BE FULL HEIGHT OF WALL AND SHALL BE
BRACED AT 6' - 8" MAXIMUM TO PREVENT MOVEMENT WHILE GROUTING.
4. HORIZONTAL REINFORCING SHALL BE IN BOND BEAM UNITS AND TIED
SECURELY TO VERTICAL REINFORCING.
5. DOWELS, ANCHORS, AND OTHER EMBEDDED ITEMS SHALL BE TIED SECURELY
IN PLACE TO PREVENT MOVEMENT WHILE GROUTING. WET SETTING OR
STABBING IS NOT ALLOWED.
6. GROUTING NOTES:
A. PROVIDE CLEAN OUTS IN THE BOTTOM COURSE OF MASONRY FOR EACH
GROUT POUR WHEN GROUT POUR EXCEEDS 4 FEET FOR 8-INCH NOMINAL
OR 5 FEET 4 INCHES FOR 10-INCH NOMINAL OR WIDER HOLLOW UNIT
MASONRY AS FOLLOWS:
a. CLEANOUT OPENINGS IN HOLLOW UNIT MASONRY SHALL BE PROVIDED
IN EVERY CELL AT THE BOTTOM OF EACH POUR OF GROUT.
ALTERNATIVELY, IF THE COURSE AT THE BOTTOM OF THE POUR IS
CONSTRUCTED ENTIRELY OF INVERTED DOUBLE OPEN-END BOND
BEAM UNITS, CLEANOUT OPENINGS NEED ONLY BE PROVIDED FOR
ACCESS TO EVERY REINFORCED CELL AT THE BOTTOM OF EACH POUR
OF GROUT.
b. CLEANOUTS IN MULTI-WYTHE MASONRY SHALL BE PROVIDED FOR
EACH POUR BY LEAVING OUT EVERY OTHER UNIT IN THE BOTTOM
WYTHE OF THE SECTION BEING POURED OR BY CLEANOUT OPENINGS
IN THE FOUNDATION.
c. THE FOUNDATION OR OTHER HORIZONTAL CONSTRUCTION JOINTS AT
THE CLEANOUTS SHALL BE CLEANED OF ALL LOOSE MATERIAL AND
MORTAR DROPPINGS BEFORE EACH POUR. THE CLEANOUTS SHALL BE
SEALED AFTER INSPECTION AND BEFORE GROUTING.
B. FOR GROUT POURS NOT GREATER THAN 4 FEET FOR 8-INCH NOMINAL OR 5
FEET 4 INCHES FOR 10-INCH NOMINAL OR WIDER HOLLOW UNIT MASONRY,
THE TOP OF GROUT POUR SHALL BE AT THE TOP OF CONSTRUCTED
MASONRY, OR WITHIN 8 INCHES OF THE TOP OF THE CONSTRUCTED
MASONRY. GROUT POURS NOT TERMINATED AT THE TOP OF
CONSTRUCTED MASONRY SHALL COMPLY WITH TMS 602, ARTICLES 3.5
C.3.A THROUGH 3.5 C.3.E.
C. GROUT POURS IN EXCESS OF 4 FEET FOR 8-INCH NOMINAL OR 5 FEET 4
INCHES FOR 10-INCH NOMINAL OR WIDER HOLLOW UNIT MASONRY SHALL
BE SUBJECT TO THE FOLLOWING:
a. GROUTING SHALL BE DONE IN A CONTINUOUS POUR IN LIFTS NOT
EXCEEDING 4 FEET FOR 8-INCH NOMINAL OR 5 FEET 4 INCHES FOR 10-
INCH NOMINAL OR WIDER HOLLOW UNIT MASONRY (FOR HIGH LIFT
GROUTING SEE DSA IR 21-2).
b. AN APPROVED ADMIXTURE OF A TYPE THAT REDUCES EARLY WATER
LOSS AND PRODUCES AN EXPANSIVE ACTION SHALL BE USED.
c. THE GROUTING OF ANY SECTION OF WALL SHALL BE COMPLETED IN
ONE DAY WITH NO INTERRUPTIONS GREATER THAN ONE HOUR.
d. FOR MULTIPLE GROUT LIFTS WITHIN A GROUT POUR, EACH GROUT
LIFT HEIGHT OF WALL, COLUMN, PIER OR BEAM SHALL BE INSPECTED
BEFORE PLACEMENT OF ADDITIONAL UNITS.
e. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF EACH
POUR OF GROUT.
D. WHERE GROUTING HAS BEEN STOPPED FOR MORE THAN AN HOUR, GROUT
SHALL BE STOPPED 1 ½ INCH BELOW A MORTAR JOINT. WHERE A BOND
BEAMS OCCUR, THE GROUT POUR SHALL BE STOPPED A MINIMUM OF ½
INCH BELOW THE TOP OF THE MASONRY WITH A MINIMUM GROUT COVER
ABOVE THE HORIZONTAL REBAR OF 1 INCH.
E. ALL GROUT SHALL BE THOROUGHLY CONSOLIDATED BY VIBRATING
IMMEDIATELY AFTER PLACING. SHAKING OR RODDING REBAR IS NOT
ALLOWED. CONSOLIDATE POURS BY MECHANICAL VIBRATION, AND
RECONSOLIDATE BY MECHANICAL VIBRATION AFTER INITIAL WATER LOSS
AND SETTLEMENT HAS OCCURRED, BUT BEFORE PLASTICITY IS LOST.
7. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE SAFETY OF LIFT
HEIGHT FOR OPEN ENDED OR FIELD MODIFIED BLOCKS.
8. LAYOUT OF MASONRY BLOCK UNITS SHALL BE RUNNING BOND.
9. PROVIDE VERTICAL CONTROL JOINTS IN CMU WALLS AS SHOWN ON PLAN.
UNLESS NOTED OTHERWISE VERTICAL CONTROL JOINTS SHALL OCCUR AT
25' - 0" O.C.
10. WHEN THE AMBIENT TEMPERATURE FALLS BELOW 40°F, OR EXCEEDS 100°F,
PROVSIONS OF TMS602 / ACI 530 / ASCE6. ARTICLE 1.8C OR ARTICLE 1.8D SHALL
BE IMPLEMENTED.
MAS…
This is the start of the file's text. The full file is on GovTribe.