LBP Bldg. 1441 (soffit & fascia).pdf

PDF 124 KB Posted

Attached to
B1441 Roof Replacement
Solicitation number
W911SG25BA029
Issued by

About this file

This LBP Testing Data Sheet documents lead-based paint (LBP) testing for Building 1441, which is part of a roof replacement project. The assessment was conducted on 4/9/2025 using a Viken/Pb200e XRF instrument (Serial Number 2759) by inspectors Frank Lujan and Paul Rodriguez. The testing revealed six sample points (LBP-01 through LBP-06) on wood soffits and metal gutters, all classified as "POSITIVE" with lead readings ranging from 1.1 to 13.3 mg/cm², and all components were rated in "POOR" condition. The testing conforms to the Texas Department of State Health Services lead measurement standard of 1.0 mg/cm² by X-ray fluorescence, indicating significant lead-based paint presence that will require remediation during the roof replacement project.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LBP TESTING DATA SHEET

Facility Information: Roof replacement

Facility Name: Building Number: 1441

XRF Model and M/N:

Viken/Pb200e Date of Assessment: 4/9/2025

XRF Instrument S/N: 2759 Inspector Name(s): Frank Lujan/Paul Rodriguez

Data Sheet

SA

M

P

LE

I D

SU

B

ST

R

A

TE

C O

M P

N

EN

T

C O

LO

R

O F

C O

M P

O N

EN

T

TE

ST

L O

C A

TI

N

D

ES

C R

IP

TI

X R

F R

EA

D

IN

G

(m g/ cm

²)

LA

SS

IF

IC

A

TI

N D

IT

IO

N/A N/A N/A Green Calibration (< 0.00) .1 ACCEPTABLE N/A

N/A N/A N/A Green Calibration (0.8 to 1.2) .7 ACCEPTABLE N/A

LBP-01 Wood Soffit Beige East end 13.3 POSITIVE POOR

LBP-02 Metal Gutter Beige East end 1.9 POSITIVE POOR

LBP-03 Metal Gutter Beige South end 1.1 POSITIVE POOR

LBP-04 Wood Soffit Beige South end 11.0 POSITIVE POOR

LBP-05 Wood Soffit Beige North end 13.0 POSITIVE POOR

LBP-06 Metal Gutter Beige North end 2.2 POSITIVE POOR

NOTES:

DPW-ED conforms to Texas Department of State Health Services lead measurement standard, 1.0mg/cm2 by X-ray fluorescence.

File details come from the government source that posted it. Updated .