LBP Bldg. 122 (soffit & fascia).pdf

PDF 126 KB Posted

Attached to
Repair Roof at B122
Solicitation number
W911SG25BA017
Issued by

About this file

This document is a Lead-Based Paint (LBP) Testing Data Sheet for a roof replacement project at Building 122, the Office of the Staff Judge Advocate facility. The testing was conducted on 4/9/2025 using a Viken/Pb200e XRF instrument with serial number 2759, performed by inspectors Frank Lujan and Paul Rodriguez. The data sheet reveals multiple wood fascia and soffit testing locations, with three soffit areas (east, north, and west ends) testing positive for lead-based paint, showing XRF readings between 5.9 and 6.4 mg/cm². The testing conforms to the Texas Department of State Health Services lead measurement standard of 1.0 mg/cm², and the components were assessed in conditions ranging from fair to intact. This testing data will likely be crucial for the upcoming roof replacement solicitation (W911SG25BA017) to ensure proper lead-based paint handling and removal protocols during the construction process.

View the file

Other files

File Type Posted
Abstract of Offerors OF_1419 Page 3.pdf PDF
Abstract of Offerors OF_1419 Page 1.pdf PDF
Abstract of Offerors OF_1419 Page 2.pdf PDF
Abstract of Offerors OF_1419 Page 4.pdf PDF
RFI Answers.pdf PDF
Site Visit Sign in Sheet.pdf PDF
Wage Determination.txt TXT text file
Asbestos Bldg. 122.pdf PDF
Drawings Repair Roof at B122.pdf PDF
Solicitation - W911SG25BA017.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LBP TESTING DATA SHEET

Facility Information: Roof Replacement-Soffit & Fascia LBP testing

Facility Name: Office of the Staff Judge Advocate

Building Number: 122

XRF Model and M/N:

Viken/Pb200e Date of Assessment: 4/9/2025

XRF Instrument S/N: 2759 Inspector Name(s): Frank Lujan/Paul Rodriguez

Data Sheet

SA

M

P

LE

I D

SU

B

ST

R

A

TE

C O

M P

N

EN

T

C O

LO

R

O F

C O

M P

O N

EN

T

TE

ST

L O

C A

TI

N

D

ES

C R

IP

TI

X R

F R

EA

D

IN

G

(m g/ cm

²)

LA

SS

IF

IC

A

TI

N D

IT

IO

N/A N/A N/A Green Calibration (< 0.00) .1 ACCEPTABLE N/A

N/A N/A N/A Green Calibration (0.8 to 1.2) 1.0 ACCEPTABLE N/A

LBP-01 Wood Fascia Green East end 0 NEGATIVE FAIR

LBP-02 Wood Soffit Green East end 6.0 POSITIVE INTACT

LBP-03 Wood Fascia Green North end 0 NEGATIVE INTACT

LBP-04 Wood Soffit Green North end 6.4 POSITIVE FAIR

LBP-05 Wood Fascia Green West end 0 NEGATIVE FAIR

LBP-06 Wood Soffit Green West end 5.9 POSITIVE FAIR

NOTES:

DPW-ED conforms to Texas Department of State Health Services lead measurement standard, 1.0mg/cm2 by X-ray fluorescence.