Attached to
GPO 5th Floor SID Smartcard Room Design/Build Construction Federal contract opportunity
Solicitation number
040ADV-25-R-0001-06
Issued by
Government Publishing Office

About this file

This is a technical floor plan layout drawing showing the design for a Smartcard room on the 5th floor of what appears to be a Government Publishing Office facility. The drawing details a secured production area with specialized equipment including card inspection machines, laser engraving systems, a robotic card inspection machine, and a 3D printer. Key security features shown include a man trap with two options, IT server rack, security system closet, UPS room, and controlled access points with features like 6' slide doors and egress with push bars.

The layout indicates separate areas for raw material and finished goods cages, a mechanical room with concrete protective finishing, various elevators (labeled EL.1, EL.2, etc.), and new carpeting in designated areas. The drawing includes precise measurements and technical specifications for equipment placement and room configurations. The space appears to be designed for secure ID card production with careful attention to access control and workflow organization.

View the file

Other files for this federal contract opportunity

Other files attached to GPO 5th Floor SID Smartcard Room Design/Build Construction, newest first.
File Type Posted
040ADV-25-R-0001-006 SF-30 (Signed).pdf PDF
SWGR Elec. Dwg.pdf PDF
Additional Questions_040ADV-25-R-0001.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F

E

D

C

ST.3

EL.10

EL.11

EL

W

ST.1

M

LIGHT COURT

A512

EL.1

VA

CA

NT

EL.2A503

MECHANICAL ROOM

EL

A501A

A502

T151

T152 A507

T152A

TRNG

CONF

A531A A531B A531D

A500

IT-5C-A

A529

A529A

A530 A530A

A531C

E-GRESS WITH

PUSH BAR

IT-SERVER RACK

SECURITY SYSTEM

CLOSET

UPS ROOM

6' SLIDE DOOR

6' S

LID

E

DO

O

R

DO

UB

LE

D

O O

R

RAW MATERIAL CAGE

FI

NI

SH

ED

G O

O D

CA

GE

FE

FE

FE

FE

FE

A512

SHAFT

C525

BRAIR

ST

VI

SI

TO

RS

E

NT

RA

NC

E

CARD INSPECTIO

N M

ACHINE

O

PTIO

N #1

LASER ENGRAVING ROBOTIC

CARD INSPECTION MACHINE

OPTION #2

3D PRINTERMAN TRAP

AutoCAD SHX Text

CARD

AutoCAD SHX Text

COUNTER

AutoCAD SHX Text 12'-11 7/8"

AutoCAD SHX Text 15'-1 1/8"

AutoCAD SHX Text 10'-6"

AutoCAD SHX Text 15'-1 1/8"

AutoCAD SHX Text 10'-6"

AutoCAD SHX Text 15'-1 1/8"

AutoCAD SHX Text 6'-9"

AutoCAD SHX Text 8'-7 1/2"

AutoCAD SHX Text

NEW CARD ISSUANCE SYSTEM #1

AutoCAD SHX Text

NEW CARD ISSUANCE SYSTEM #2

AutoCAD SHX Text 16'-0"

AutoCAD SHX Text 11'-0"

AutoCAD SHX Text 31'-0"

AutoCAD SHX Text 28'-0"

AutoCAD SHX Text 11'-0"

AutoCAD SHX Text 16'-0"

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text POWER REQUIREMENTS 230 VAC (2 WIRE + PE) 25A Max, 50-60 Hz Fuse: 30A, 250V, 10 KA.I.R

AutoCAD SHX Text POWER REQUIREMENTS 240 VAC, 24A, 50-60 Hz

AutoCAD SHX Text POWER REQUIREMENTS 230 VAC (2 WIRE + PE) 25A Max, 50-60 Hz Fuse: 30A, 250V, 10 KA.I.R

AutoCAD SHX Text POWER REQUIREMENTS 240 VAC, 24A, 50-60 Hz

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

CARD

AutoCAD SHX Text

COUNTER

AutoCAD SHX Text POWER REQUIREMENTS 230 VAC, 12A, 50-60 Hz

AutoCAD SHX Text POWER REQUIREMENTS 230 VAC, 12A, 50-60 Hz

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

RACK

AutoCAD SHX Text

PIN

AutoCAD SHX Text

PRINTER

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

RACK

AutoCAD SHX Text

REMOVE THIS WALL & DOORDOOR

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text 5'-4 9/16"

AutoCAD SHX Text 8'-5"

AutoCAD SHX Text

NEW CARD ISSUANCE SYSTEM #2

AutoCAD SHX Text 28'-0"

AutoCAD SHX Text 11'-0"

AutoCAD SHX Text 16'-0"

AutoCAD SHX Text POWER REQUIREMENTS 230 VAC (2 WIRE + PE) 25A Max, 50-60 Hz Fuse: 30A, 250V, 10 KA.I.R

AutoCAD SHX Text POWER REQUIREMENTS 240 VAC, 24A, 50-60 Hz

AutoCAD SHX Text POWER REQUIREMENTS 12A, 230 VAC, 50-60 Hz

AutoCAD SHX Text 6'-5"

AutoCAD SHX Text 20'-0"

AutoCAD SHX Text 10'-0"

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text

NEW CARD ISSUANCE SYSTEM #3

AutoCAD SHX Text 15'-0"

AutoCAD SHX Text 14'-0"

AutoCAD SHX Text POWER REQUIREMENTS 230 VAC (2 WIRE + PE) 25A Max, 50-60 Hz Fuse: 30A, 250V, 10 KA.I.R

AutoCAD SHX Text POWER REQUIREMENTS 240 VAC, 24A, 50-60 Hz

AutoCAD SHX Text POWER REQUIREMENTS 12A, 230 VAC, 50-60 Hz

AutoCAD SHX Text 15'-0"

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 6'-8 3/8"

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text 10'-0"

AutoCAD SHX Text 6'-0"

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text 10'-0"

AutoCAD SHX Text 16'-0"

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text 15'-0"

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text

2' X 6' RACKS

AutoCAD SHX Text

2' X 6' RACKS

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text 10'-0"

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 3'-11 1/8"

AutoCAD SHX Text POWER REQUIREMENTS 230 VAC (2 WIRE + PE) 25A Max, 50-60 Hz Fuse: 30A, 250V, 10 KA.I.R

AutoCAD SHX Text POWER REQUIREMENTS 230 VAC (2 WIRE + PE) 25A Max, 50-60 Hz Fuse: 30A, 250V, 10 KA.I.R

AutoCAD SHX Text POWER REQUIREMENTS 115...240V; 50-60 Hz; 2P/PE 20A Max; 870VA/830W; Line Fuse: 20A, COMPRESSED A.I.R

AutoCAD SHX Text POWER REQUIREMENTS 13KWATT; 110V/220V, 50-60 Hz

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text 8'-7 1/2"

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text

BIO

AutoCAD SHX Text

CARD

lgallegos Polygon lgallegos Rectangle lgallegos Polygon lgallegos Callout Concrete with Protective Finish lgallegos Callout New Carpet lgallegos Callout New Carpet

Sheets and Views
D1-8 NEW SMART CARD OPERATION ON 5TH FLOOR-Model

File details come from the government source that posted it. Updated .