This technical specification document details the requirements for a Cobalt-60 gamma irradiator for the Oak Ridge National Laboratory's Nuclear Energy and Fuel Cycle Division. The specifications include a minimum of 8000 Ci Cobalt-60 with a variable dose rate of at least 5 x 10^5 R/hr, a chamber minimum of 10" wide x 10" high x 40" long, and a total footprint not exceeding 48" wide x 168" x 96" long. The device must weigh no more than 15,000 pounds and operate on 115 Volts, 60 Hz at 5 amps.
Critical safety features include electro-mechanical interlocks to prevent accidental exposure, automatic source return to a fully shielded position during power failures or pneumatic pressure loss, and external radiation levels not exceeding 5 mR/hr at 12" from the surface. Additional requirements include motorized door openers, access ports for instrument wires/fluid piping, pneumatically driven irradiation control, and the possibility of on-site reloading. The document is dated May 16, 2025, prepared under DOE Contract Number DE-AC05-00OR22725 between the US Department of Energy and UT-Battelle LLC.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP PR398739 - For Posting.pdf | ||
| 2025.06.09 - WDP - Lab 125 Irradiator Statement of Work- Signed (002).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL SPECIFICATIONS:
COBALT-60 IRRADIATOR
May 16, 2025
Prepared by Randy Ngelale
Principal investigator: Randy Ngelale
Nuclear Energy and Fuel Cycle Division
Oak Ridge National Laboratory
Oak Ridge, Tennessee 37831
Prepared under DOE Contract Number DE-AC05-00OR22725 between the US Department of Energy and UT-Battelle LLC
Fusion and Fission Energy and Science Directorate
Nuclear Energy and Fuel Cycle Division
TECHNICAL SPECIFICATION
Document Number: FCCT-SPEC-01 Revision: 0
Document Title: NEFCD Gamma Irradiator
Effective Date: May 16, 2025
Approval
Title Name Signature Date
Originator Randy Ngelale, R&D Staff , FCCT
Approver Richard Mayes, Group Lead, FCCT
This report was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof.
Fusion and Fission Energy and Science Directorate
Technical Specifications: Gamma Irradiator
Rev. 0
05/16/2025
1. REVISION HISTORY
Revision No.
Effective Date Description of Change(s)
0 05/16/2025 Initial issue
Technical Specifications: Gamma Irradiator
Rev. 0
TABLE OF CONTENTS
1. REVISION HISTORY
2. SCOPE
3. TECHNICAL SPECIFICATIONS
3.1 Activity & Dose
3.2 Chamber Dimensions
3.3 Instrumentation and Access Tubes
3.4 Footprint
3.5 Weight
3.6 Power
3.7 Air Supply
3.8 Sealed Source and Device approvals
3.9 Reloading
3.10 Motorized Door Openers
3.11 External Radiation Levels
3.12 Safety
Technical Specifications: Gamma Irradiator
Rev. 0
2. SCOPE
This technical specification document applies to the mechanical design of a Cobalt-60 irradiator.
3. TECHNICAL SPECIFICATIONS
3.1 Activity & Dose
Minimum 8000 Ci Cobalt 60. Variable dose based on position with a minimum of 5 x 105 R/hr
3.2 Chamber Dimensions
Minimum 10” wide x 10” high x 40” long. Movable platform is desirable.
3.3 Instrumentation and Access Tubes
Must have access ports available for instrument wires and/or fluid piping.
3.4 Footprint
Not to exceed 48’’ wide x 168” x 96” long.
3.5 Weight
Not to exceed 15,000 pounds.
3.6 Power
115 Volts, 60 Hz, rated at 5 amps.
3.7 Air Supply
Pneumatically driven irradiation control. Possibility for connection of an industrial air supply.
3.8 Sealed Source and Device approvals
Sealed Source and Device Sheets required.
3.9 Reloading
On-site reloading capability is desirable.
3.10 Motorized Door Openers
Must be supplied with motorized door openers and appropriate interlocks.
Technical Specifications: Gamma Irradiator
Rev. 0
3.11 External Radiation Levels
Typical external radiation levels must at or below 5 mR/hr maximum at 12” from surface.
3.12 Safety
• Electro-mechanical interlocks to prohibit accidental irradiation or exposure.
• In the event of power failure, the sources must automatically return to the fully shielded position by pneumatic pressure, or lack thereof.
• In the event of failure of pneumatic pressure, the sources must return to the fully shielded position.
• The access tubes (Item #2.3) must be configured or interlocked to prevent accidental exposure.
| 2025-06-26T14:54:13-0400 | |
| Richard Mayes |
| Date2_af_date: 6/26/25 | |
| 2025-06-11T09:57:43-0400 | |
| RANDY NGELALE (Affiliate) |
Date4_af_date: 6/11/25