Maps Drawings.pdf

PDF 8 MB Posted

Attached to
Horse Creek Fences Federal contract opportunity
Solicitation number
L15PS00372
Issued by
Department of the Interior Bureau of Land Management Montana-Dakotas

About this file

Maps and Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Horse Creek Fences, newest first.
File Type Posted
Sol_L15PS00372_Amd_000001.pdf PDF
Q A_Document.docx DOCX document
TOC.docx DOCX document
SOI.doc DOC document
HCFn1_(2).xls XLS spreadsheet
Spec.doc DOC document
Sol_L15PS00372.pdf PDF
P3-SubContractorInfoRequest.pdf PDF
MT80.txt TXT text file
Past_Performance_Questionnaire.doc DOC document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PART VII

PLANS & DRAWINGS

HORSE CREEK FENCES 2015

MILES CITY DISTRICT OFFICE

MILES CITY, MONTANA

INDEX

Page No. Drawing No. Title

1 of11 N/A Area Reference Map 2 & 3 of 11 N/A Area Map 4 of 11 to 11 of 11 N/A Work Location Map 02834(1) Four Wire Fence 02834(5) Fig. Four & Rock Jack

02834(6) Wire Gates 02834(9) Corner Panels

HORSE CREEK FENCES 2015

,Spike

I II

,6'-6" loIin. brace", I . \ ~1-I-~-."..S~~:..-I01_:_.s_e_D~_ta+iI+v---,::.".,./,~_/ /-+-+ t 6'-6" t.lin.~ 6'-0" loIin. -----l!f-- ~ ,'-," .," -L ,'-," '"" J

END PANEL-TYPE I END PANEL-TYPE II

L -------l0l-LI'

(wood or6'-6" loIin. Add additional wire of the some moterlal as bottom wire steel) of fence and a rock deadman (min. weight 50 Ibs.) when spoce between bottom wire and ground exceed 20 inch...

STRESS PANEL PANEL AT MINOR DEPRESSION

I' L -----0*1-·--L--+-f------+-1·- L -

==:=~::====--~--*---====:r=9=-:G=a-.-s~m-oo-t-h~~~V-.:w=ir=e=tj:= li ~~~~~~~~~(~~~~~~,~~vt

V M~

--+-+~---+_I------+Io~=

~~V fr~~2loI~in'~"-'~-'-~~~~~~l''rr ~

Twisted wood stayw~r

LINE PANELS

NOTE: -+- I 1"--Ti!=

1. See .pacification. for the fonowing: _," .......--t

a. Ratio of steel to wood line posts.

b. Post spocing, length and depth in ground.

c. Type of end ponel to be used.

d. Type of wire to be used.

e. Spacing between wire•. V· Spike spiking

f. Number of stays per spon (L). ~or toe nailing l+ os specified)

I--Steel line post uNITED STATES CE?ARTM[NT OF THE iNTERIOR

8U?'£l..U OF L.r.~;D I.(AN;'CEI.IENT

DIVISIO~~ OF TECHNICAL SERVICES SERVICE CETliER rfPICAL

BARBED WIRE FENCE

(4-WIRE)

MORTISE DETAIL

CESICNED

RSVIE\\ED

by elhers

~.~. /tb L -

APPROvED Aa. ./.2L ~J~ (/

DRA\'o~, J I SCALE NONE AL 'JAYS THINK SAF E T Y J-D-A-TE--F-E-8-RU-AR-Y-2-5-.-1-9-9-1-II~SH-.E-E--T---O-F~-----i

DRAWING NO. 0,8)4-1

--I J- 3" (IoCII.)

y otl I ...

5 -6 Post

FIGURE FOUR-SIDE

Barbed Wire Fence

Broce Post

FlCURE FOUR - PlAN VIEW

ROCK JACK- PLAN

ROCK JACK-FRONT

FIGURE FOLIR & ROCK JACK

DESICNED --""-:-:;r..:......-r----::n-~"-----

REVIEWED

APPROvED

DRAWN:

_I ROCK JACK-SIDE: (JIqdw II! plou)

A1.. .......,$ THlNC SAFETY

Panel 16'-6" c.c.

Smooth wire loop (see specifICations for gauge)

4-3" , wood stays evenly spaced Smooth wire loop or .t.el strop (see speclfieotions for gouge)

Mechanical gate clo ..r i

WOVEN WIRE GATE

I Panel poet spacing 16'-6" c.e. I 3" Min. hanical gate clo.er , 1

M ~--i ~

.L, l 6" Min.

~ Smooth wire loop (... specifications for gauge) 4-3" " wood stays evenly spaced

WIRE GATE

TYPE A

rt.tec r::::

p-tr

I\r- smoot h wire loop (.ee or steel strop speciflCOtions for gouge)

TYPE B

i

Panel 16'-6" C.c.

3" Min•

.L

Smooth wire loop (... speciflCCltions for gouge) 4-3" " wood slays evenly spaced

WIRE GATE

Smooth wire loop or steel sI:n:Ip (s.. apeclf1eations for gauge)

UNHEQ STATES O[PARTI.lENT Of' THE INTERIOR

BUREAu Of' ~O MANAC£~ENT

DIVISION OF TECHNICAL SERVICES SERVICE CENTER

NOTES:

TYPICAL

1. The opening end of gate shal be provided with smooth wire loop at bottom of end stay as is cammon practice for fastening wire gap gates or as WIRE GATES modifMld for gat.. with mechanical gate clOle

2. Construct an end or stres. panel an each side of type required In the .peclflCCltians.

AL'w'AYS THINK SAFETY

SCAL£ NON~

SHEET. OF

3-POST

CORNER PANEL

5-POST

CORNER PANEL

(TYPE I)

5-POST

CORNER PANEL

(TYPE II)

UNITED svm:s OEP'!'RTUENT or THE INfERIOR

SVR!:Au or lANO I.lANAGE),jENT

OiVlSICN or rECHNIC>1. SERvICES SERvICE CENrE~

NOTES:

CORNER PANELS1. Refer to the specifications for type of comer panel' to use.

2. Number of wim, type of wire, and wire spacing some as for fance. Posta sholl be 88t II inch.. deeper than Rna pasts. Oe:SIGNEO

3. Use spikes at juncturslI and mortise ,. deep at juncturell of pasts and braces.

f'le:vt£\'fEO4. Maximum ,pacing between pasta shall be 8'-3" C.c.

APPROVEO

ORAWN

ALWAYS THINK SAFETY t-;;-;;;:~=~,.-::;;;--::~I-::-=:----:-::-~----i

DwgsMapsTOC
ARfMp
AMp
AMp2
WkMp1
WkMp2
WkMp3
WkMp4
WkMp5
WkMp6
WkMp7
WkMp8
Barbed Wire Fence
Rock Jacks
Wire Gates
Corner Panels