Kenosha Co. PSB Employee Jail Elevator Bid 2506 - PLAN 1.29.25.pdf

PDF 671 KB Posted

Attached to
Kenosha County Public Safety Building Employee Jail Elevator Repair
Solicitation number
2506
Issued by
Kenosha County, Kellnersville Village, Wisconsin

About this file

This is a set of architectural plans and specifications for the Kenosha County Public Safety Building Employee Jail Elevator project (Bid #2506) located at 1000 55th Street in Kenosha, Wisconsin. The document, dated January 29, 2025, includes floor plans, general notes, and specifications prepared by Kueny Architects of Pleasant Prairie, Wisconsin, with Jon P. Wallenkamp listed as the Architect of Record.

The plans show detailed floor layouts of the Public Safety Building's first floor, with particular focus on the elevator equipment area. The general notes specify 4000 psi concrete requirements, contractor responsibilities, utility verification requirements, and safety protocols. The document includes material indications, drawing legends, and standard architectural symbols for various building materials and components, though specific elevator equipment specifications are not detailed in this portion of the plans.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1807 1806 1805 1804 1803 1802 1801 1800

1702 1701

19051906

1750 1500

1454 1450

1414 1411

1419 1409

1201 1200

1011 1010

1252 1253

1055 1056

11011103

11041102110511501151

11531152

1361 1360 1359 1358 1357 1356

1308 1306

110711091110

13071352

LARGE PROPERTY AND EVIDENCE

CORRIDOR

CAD ROOM

BASE STATION

OFFICE

VESTIBULE

COMMUNICATIONS CENTER

INTERVIEW INTERVIEW HOLDING HOLDING DETECTIVE STORAGE INTERVIEW HOLDING HOLDING

DETECTIVES

SGT DETECTIVES

RECEPTION

JUVENILE DETECTIVES

CONFERENCE

STORAGE

SGT PATROL

CAPTAIN OPERATIONS

LT. PATROL

SMALL PROPERTY AND EVIDENCE

EVIDENCE LOCKERS EVIDENCE OFFICE

ALARM AND TELEPHONE

VESTIBULE

JANITOR

ELEVATOR EQUIPMENT

VEHICLE SALLE PORT

TRASH COMPACTOR

CENTRAL RECEIVING

JAIL RECEIVING

DWI TESTING

DWI TESTING

TOILET

HOLDING

HOLDING

WOMEN

WOMEN'S LOCKER

MENMEN'S LOCKER

MECHANICAL

MECHANICAL

MECHANICAL

FLEET MAINT STORAGE

LOCKERS

TOILET

FLEET MAINT OFFICE

FLEET MAINTENANCE

CAR WASH

IMPOUND BAYS

LUNCHROOM

JANITOR

LIBRARY

IMPOUND BAYS CENTRAL RECORDS

RECORDS SUPERVISOR

ID OFFICE

VESTIBULE ID WORKROOM

DARKROOM

PUBLIC COUNTER

RECORDS VIEWING

VIEWING

POLYGRPAH INTERVIEW

POLYGRAPH TEST POLYGRAPH TEST

POLYGRAPH INTERVIEW

COURT OFFICERS

WAITING TOILET

MEN

JANITOR

LT. PATROL

CONFERENCE

LT PATROL CAPTAIN SERVICES

COMMUNITY RELATIONS TRAINING

WORKROOM

CHIEF DEPUTY

CONFERENCE

SHERIFF

CLOSET

TOILET

STORAGE

WOMEN

CIVIL PROCESS

CIVIL PROCESS

RECEPTION

VESTIBULE

LOBBY

WOMEN

MEN

JANITOR

RECEPTION

CORONER CIVIL DEFENSE DIRECTOR

CLOSET

CLOSET

CONFERENCE

RECEPTION

SECRETARY

BUILDING MANAGER

POLICE CHIEF

CLOSET TOILET

CAPTAIN OPERATIONS

CAPTAIN OPERATIONS

CAPTAIN OPERATIONS

SECRETARY

CONFERENCE

DEPUTY CHIEF PATROLCPT SAFETY TRAINING

CORRIDORCAPT ADMINDEPUTY CHIEF INVESTCAPT INT AFFAIRSLT INT AFFAIRS

DEPUTY CHIEF INVEST

DETECTIVE FRAUD

LT DETECTIVESDETECTIVE NARCOTICS

DETECTIVES

STORAGE STORAGE HOLDING HOLDING INTERVIEW INTERVIEW

RECEPTION

CONFERENCE

LT DETECTIVES

MEN

WOMEN

WAITING COURT OFFICER-TRAFFIC

JUVENILE DETECTIVES

INTERVIEW

INTERVIEW

HOLDING

HOLDING

COURT OFFICER-JUVENILE

LT OPERATIONS

SGT OPERATIONS

STORAGE

PARKETTESGT SAFETYLT SAFETY

SCHOOL SAFETY

COURT - DETECTIVE

MENWOMEN

JANITOR

MECHANICAL

ELEVATOR EQUIPMENT

PROJECT LOCATION

PROJECT

LOCATION

7'-2"

/2

1.0KUENY ARCHITECTS, LLC

10505 CORPORATE DRIVE - SUITE 100 PLEASANT PRAIRIE, WI 53158 PHONE (262) 857-8101 FAX (262) 857 8103

SITE MAP GENERAL NOTES

1. All concrete to test 4000 psi in 28 days.

2. Verify all dimensions, access, utilities and working conditions in the field.

3. Conform to all applicable codes, ordinances and safety standards.

4. Obtain and pay for all required permits and fees.

5. Notify Architect immediately if work cannot proceed as shown on Drawings or as described in the Specifications.

6. No concrete to be poured without Architect's prior review.

7. All Contractor's to co-operate with all trades, Owner's and Architect's representatives.

8. Leave site clean, neat and free of debris at all times.

9. Each Prime and Sub-contractor is responsible for having read each page of the Specifications, Drawings, Addenda and Change Orders.

10. Guard against interfering with Owner's operations.

11. These Drawings contain no provisions or procedures for on-site safety. Each

Contractor and their employees are responsible to follow all laws and ordinances and provide their own engineering to provide a safe work place.

12. The locations of existing underground utilities, shown on these Drawings, are shown in an approximate way only and have not been independently verified by the Owner or its representatives. The Contractor shall determine the exact location of all existing utilities before commencing work, and agrees to be fully responsible for any and all damages which might be occassioned by the Contractor's failure to exactly locate and preserve any and all underground utilities.

13. Services perform for this project have been conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing in this area under similar budget and time constraints. No warranty, expressed or implied, is made.

MATERIAL INDICATIONS

DRAWING LEGEND

New or Required Point Elevation

Existing Point Elevation

Existing Contours

New or Required Contours

A Grid Lines

3.1 Building Section

Wall Section

Room/Space Number

Door Number

SHEET INDEX

Earth Backfill

Rigid Insulation

Concrete Block

Aluminum

Lumber (Rough)

Steel

Sand Fill

Concrete

Finished Wood

Stone Fill

Plywood

Batt Insulation

4.1

Room 1

101 Interior Elevation

Detail Section

5.1

7.1

CONSULTANTS

5.1

Detail Number

Page Number

Exterior Elevation

2.1

1 Wall Tag

+ 100.0

+ 100.0

+ 100.0

+ 100.0

Employee Jail Elevator Bid #2506

Kenosha County Public Safety Building Employee Jail Elevator Bid #2506

Kenosha Co. Public Safety Building 1000 55th Street Kenosha, WI

53140

January 29, 2025

PROJECT

LOCATION

General Floor Plan - First Floor

Enlarged Floor Plan

ARCHITECT Kueny Architects 10505 Corporate Drive, Suite 100

(262) 857-8101 Pleasant Prairie, Wisconsin 53158 Architect of Record - Jon P. Wallenkamp

Sheets
EL-1.0 - Title Sheet

File details come from the government source that posted it. Updated .