Justification to Restrict Competition - Under SAT - Open Market - CT Inj (1)_Redacted.pdf

PDF 854 KB Posted

Attached to
CT Injection System-Zuni Comprehensive Community Health Center (ZCCHC)
Solicitation number
75H70726Q00094
Issued by

About this file

This document is a Justification to Restrict Competition (JTC) for a below-SAT simplified acquisition by the U.S. Department of Health and Human Services, Indian Health Service, Albuquerque Area.

The contracting officer documents the decision that only one source—Bayer HealthCare LLC, located at 1 Bayer Drive, Indianola, PA 15051—is reasonably available for the acquisition of a Medrad Stellant Flex Overhead Counterpoise CT Injection System. The justification specifies that the current CT injector system at Zuni Service Unit requires replacement due to end-of-life status and inability to support the 24/7 hospital demand. The replacement system must be compatible with the existing CT scanner, and no alternative injection system type will work with the current equipment setup. Since only one CT scanner operates at the facility 24/7, equipment replacement must ensure continuity of operations and patient care without disruption. The contractor shall provide the Medrad Stellant Flex system with installation, two 150 ml flex syringes with tubing and accessories, shipping and handling, and a one-year original equipment manufacturer warranty. Additional deliverables include coordination with the Zuni Service Unit Radiology Department for installation scheduling, completion of installation and functional testing with the contractor's own tools, liability insurance coverage, and written reports documenting installation and functionality. Technical specifications include injection flow rates of 0.1–10 mL/sec, syringe volumes of 150 or 200 mL, programmable pressure limits, scan reminders and pause functions, electrical requirements of 100–240 VAC at 50/60 Hz, and syringe heat maintenance at 35 degrees C ±5 degrees. The document was prepared by Michelle Sanchez on August 14, 2026, and was to be signed by the Contracting Officer.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation or Award Number: Page 2 of 4

Rev. 09/30/2025

Scan Reminders: 0–300 Seconds (5 minutes) in 1 Second Increments Pause: 1–900 Seconds (15 minutes) in 1 Second Increments Hold: Maximum HOLD Time is 20 Minutes Syringes (Volume capacity): 150 mL or 200 mL Sterile Disposable Syringe Maximum Number of Phases: 6

Miscellaneous Specifications:

Electrical Requirements (VAC/Hz): 100–240 VAC, 50/60 Hz, 300 Volts-Amps Syringe Heat Maintainer: 35 degrees C +/–5 degrees, 95 degrees F +/–9 degrees Head Mounting Options: Overhead Counterpoise System DualFlow: Simultaneous Injection of Contrast and Saline is integrated in the Certegra® Workstation (CWS) and included VirtualCARE® Remote Support: Remote service on the injector and software to ensure faster uptime

Dual Injector Head: Height 14.5" (36.8 cm), Width 12.1" (30.7 cm), Depth 6.0" (15.2 cm), Weight: 16.8 lb (7.6 kg) (without syringe) Base Unit 11.3" (28.6 cm), Width 11.0" (27.9 cm), Depth 9.0" (22.9 cm), Weight 13.6 lb (6.2 kg)

Scope: Under the terms and conditions the contractor shall:

Provide a Medrad Stellant Flex Overhead Counterpoise CT Injection System Installation of Medrad Stellant Flex CT Injection System – Overhead Counterpoise

System Provide 2-150 ml Flex Syringes, 60” Tubing w T connector, 2 Small Spikes/20 per box Shipping and Handling One-Year Original Equipment Manufacturer Warranty on the Medrad Stellant OCS CT

Injection System Schedule with Zuni Service Unit Radiology Department, COR and ALT COR on delivery/installation dates and times to ensure continuity of hospital services.

No certification of immunization is required due to installers who will not interact with patients/customers.

Vendor is required to cover liability insurance for their installation team.

Installation team will be required to supply own tools to complete install, test and start up.

Vendor will provide written reports of installation and functionality to the Radiology Department manager before leaving the Zuni Service Unit.

Solicitation or Award Number: Page 4 of 4