Jupiter Plantation Ditch Topographic Survey.pdf
PDF 2 MB Posted
- Attached to
- Jupiter Plantation Ditch Pipe Replacement
- Solicitation number
- IFB 360 2022604 2
- Issued by
- Palm Beach County, Florida
About this file
This is a Topographic/Specific Purpose Survey document prepared by Ritzel-Mason Inc. for Palm Beach County, Florida's Department of Roadway Production Engineering and Public Works related to the Jupiter Plantation Ditch Pipe Replacement project (Project No. 2022604). The survey was conducted to establish the location of right-of-way lines and document topographic features within the contract limits along a 500-foot baseline extending from station 10+00 to station 15+00. The field survey was completed on November 8, 2024, and the document provides detailed measurements, elevations, and site conditions for the proposed pipe replacement work. The survey includes horizontal and vertical control data, with elevations referenced to the North American Vertical Datum of 1988 (NAVD88) and coordinates based on the Florida East Zone 0901 State Plane coordinate system using NAD83/90 horizontal datum.
The survey delineates existing infrastructure including drainage easements ranging from 6 to 35 feet in width, underground utilities (electrical, fiber optic, and cable television), and existing pipe conditions such as 48-inch reinforced concrete pipes (RCP) with inverts at various elevations. Topographic data was collected using total station methods and hydrodrone equipment for underwater canal data, achieving horizontal accuracy of 1:230,000 and vertical accuracy of 0.025 feet through conventional differential leveling. The survey encompasses Crown Quay Lane, portions of the Loxahatchee River, and Jupiter Plantation First Addition properties, documenting water elevations, wall heights, and existing surface features critical to the pipe replacement design. The certification was completed by Dennis A. Ritzel, Florida-registered professional surveyor and mapper (Registration No. LS6953), confirming compliance with Florida Board of Professional Surveyors and Mappers standards and 2019 Palm Beach County Design Procedures.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2022604 RFI Form.pdf | ||
| 2022604 Spec Book (2).pdf | ||
| 2022604 Pre-Bid Sign in Sheet.pdf | ||
| Final Pipe Replacement Plans 01-6-2026.pdf | ||
| OSBD Schedules and Instructions.pdf | ||
| Qualifications and Experience Package Form.pdf | ||
| 2022604.5 Pay Item Worksheet_06_04_2026.xlsx | XLSX spreadsheet | |
| Jupiter Plantation Ditch Pipe Replacement Structures_Plans_SS.pdf | ||
| Alternate Format Availability.pdf | ||
| 2022604 RFI Form.docx | DOCX document | |
| Qualifications and Experience Package Form.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OF: SV3
24-090
PROJECT NO.
SHEET: SV1
NTS
DR
DD
DR
11/8/24DATE:
CHK'D:
DRAWN:
APP'D:
SCALE:
P A
L M
BE
ACH
Y T
N U
OC
F
LORID
A
ROADWAY PRODUCTION
ENGINEERING AND PUBLIC WORKS
PALM BEACH COUNTY
P.O. BOX 21229, WEST PALM BEACH, FLORIDA
By DateRevisionsNo.
Seal:
PROJECT NO. 2022604
PALM BEACH COUNTY
PALM BEACH COUNTY, FLORIDA
REPLACEMENT
JUPITER PLANTATION DITCH PIPE
TOPOGRAPHIC/SPECIFIC PURPOSE SURVEY
LB8265
Delray Beach, Florida 33484 · 561.634.6701
5119 Beechwood Rd, A SURVEYING AND MAPPING FIRM
RITZEL-MASON INC.
STATE OF
A
DIROL
F
LEZTIR SINNED
E T
ACIFIT
R
E
C r e p p a M dna royevru
S de r et si g e
R
No. 6953
PA
L
M
BE
ACH
Y T
N U
OC
FLORIDA
COUNTY OF PALM BEACH
BOARD OF COUNTY COMMISSIONERS
SARA BAXTER
DISTRICT 6
DISTRICT 4
DISTRICT 2
DISTRICT 1
MICHAEL A. BARNETT
DISTRICT 3
DISTRICT 5
MACK BERNARD
DISTRICT 7
GREGG K. WEISS
MARCI WOODWARD
STATE OF FLORIDA
MARIA G. MARINO
MARIA SACHS
PROJECT NO. 2022604
PIPE REPLACEMENT
JUPITER PLANTATION DITCH
NOTES:ABBREVIATIONS:
SURVEYOR'S CERTIFICATION:
TWP. 40S., & RGE. 42E.
SEC. 36
NOT TO SCALE
LOCATION MAP
LEGEND:
TREE UNKNOWN
TREE PINE
TREE PALM
TREE OAK
SINGLE SUPPORT SIGN
SECTION CORNER
POWER POLE
LIGHT POLE
IRRIGATION VALVE
GUY ANCHOR
=UNKNOWNUNK
=TOWNSHIPTWP.
=TOP OF WALLT.W.
=TRAVERSETRAV
=STATIONSTA.
=SECTIONSEC.
=SET NAIL AND DISCSN/D
=RIGHT OF WAYR/W
=RANGERNG.
=RITZEL-MASON INC.RM
=QUANTITY QTY.
=QUALITY LEVEL B (QLB)(B)
=POINTPT
=POINT OF INTERSECTIONP.I.
=PARCEL CONTROL NUMBERPCN
=NUMBERNO.
=INVERTINV.
=IRON ROD & CAPIRC
=GUARDRAILGR
=FLORIDA DEPARTMENT OF TRANSPORTATIONFPL
=FINISHED FLOOR ELEVATIONFFE
=ELEVATIONEL.
=EDGE OF PAVEMENTE/P
=CONCRETECONC.
=CENTERLINE
+BURIED CABLE TELEVISION BTV(B)
BFOC(B) =BURIED FIBER OPTIC
=BURIED ELECTRICBE(B)
=BEGININGBEG
=BASELINE
=ASPHALTAP
LAST DATE OF FIELD SURVEY: 11/08/2024
FLORIDA REGISTRATION NO. LS6953
PROFESSIONAL SURVEYOR AND MAPPER
DENNIS A. RITZEL
RESPONSIBLE DIRECTION AND SUPERVISION.
STATUTES, THE 2019 PALM BEACH COUNTY DESIGN PROCEDURES AND IS A TRUE AND CORRECT REPRESENTATION OF THE LAND SURVEYED UNDER MY PROFESSIONAL SURVEYORS AND MAPPERS IN RULE 5J-17.050-.052, OF THE FLORIDA ADMINISTRATIVE CODE PURSUANT TO CHAPTER 472.027, FLORIDA I HEREBY CERTIFY THAT THIS SPECIFIC PURPOSE/TOPOGRAPHIC SURVEY MEETS THE STANDARDS OF PRACTICE SET FORTH BY THE FLORIDA BOARD OF
COMPUTED DIMENSIONS ARE SUPPORTED BY FIELD MEASUREMENTS. 12.
REFERENCE FIELD BOOK 22, PAGE 49 AND FIELD BOOK 25, PAGE 21 11.
COLLECTED BY HYDRODRONE EQUIPMENT COMBINED WITH TOTAL STATION EQUIPMENT.
10. TOPOGRAPHIC DATA COLLECTED BY TOTAL STATION METHODS. UNDERWATER CANAL DATA WAS
FORM A CONSISTENT PATTERN REFLECTING AN OVERALL AGREEMENT WITH RECORD DOCUMENTS.
RECORDED IN THE PUBLIC RECORD OF PALM BEACH COUNTY. THE RECOVERED MONUMENTS WERE FOUND TO OFFICIAL RECORD BOOK 1049, PAGE 398, AND OFFICIAL RECORD BOOK 34, PAGE 162). ALL DOCUMENT AS
LANE (PLAT BOOK 60, PAGE 164) AND EASEMENT DEEDS AS RECORDED IN OFFICIAL RECORD BOOK 1040, PAGE 396, EASEMENT AND THE 15-FOOT DRAINAGE EASEMENT WERE PRIMARILY BASED UPON THE PLAT OF CROWN QUAY THE RIGHTS-OF-WAY FOR CROWN QUAY LANE, THE 35-FOOT DRAINAGE EASEMENT, THE 20-FOOT DRAINAGE 9.
BASELINE OF SURVEY AND SHOW THE TOPOGRAPHIC FEATURES WITHIN THE CONTRACT LIMITS.
THE SPECIFIC PURPOSE OF THIS SURVEY IS TO ESTABLISH THE LOCATION OF THE RIGHT-OF-WAY LINES, 8.
PROPERTIES WHICH ARE UNKNOWN TO THE SIGNING SURVEYOR AND ARE NOT SHOWN ON THIS SURVEY.
UNRECORDED DEEDS, EASEMENTS, RESTRICTIONS OR OTHER INSTRUMENTS WHICH COULD AFFECT THE SUBJECT MISSING SEGMENTS IN THE RIGHT-OF-WAY CORRIDOR IT IS POSSIBLE THAT THERE ARE DEEDS OF RECORDS, REVIEWED BY THIS OFFICE AND INCORPORATED HEREIN. THIS OFFICE HAS FOUND NO GAPS, GORES, OVERLAPS, OR
THE RIGHT-OF-WAY INFORMATION PROVIDED BY PALM BEACH COUNTY ON AUGUST 19, 2024, HAS BEEN 7.
6. PARCEL CONTROL NUMBERS WERE OBTAINED FROM THE PALM BEACH COUNTY PROPERTY APPRAISER.
PLAT BOOK 60, PAGE 164 AND FIELD MONUMENTATION.
GRID BEARING OF NORTH 01°00’22” EAST AS CALCULATED FROM THE PLAT OF CROWN QUAY LANE AS RECORDED IN
BEARINGS SHOWN HEREON ARE BASED ON THE WEST RIGHT-OF-WAY LINE OF CROWN QUAY LANE, HAVING A 5.
POINT: N=949988 E=946899. COORDINATES ARE GRID. ALL DISTANCES ARE GROUND.
PROJECT SCALE FACTOR = 1.000038084 (GROUND DISTANCE X SCALE FACTOR = GRID DISTANCE). SCALE FACTOR
UNITS = US SURVEY FEET. COORDINATE SYSTEM = 1983 STATE PLANE TRANSVERSE MERCATOR PROJECTION.
HORIZONTAL DATUM = NAD 1983, 1990 ADJUSTMENT (NAD83/90). ZONE = FLORIDA EAST ZONE 0901. LINEAR 4.
REDUNDANT MEASUREMENTS.
1.09 MILES. THE HORIZONTAL ACCURACY OF THE FIELD MEASURED CONTROL IS 1:230,000 BASED UPON
THE VERTICAL ACCURACY OF THE CONVENTIONAL DIFFERENTIAL CLOSED LEVEL LOOP OBTAINED IS 0.025' IN 3.
AN ELEVATION OF 3.226 FEET.
AND REFERENCE THE FOLLOWING BENCHMARK: PALM BEACH COUNTY BRASS DISC IN CONCRETE CENNOCK HAVING
ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) 2.
SIGNATURE OF A FLORIDA LICENSED SURVEYOR AND MAPPER.
THIS DRAWING IS NOT VALID WITHOUT THE ORIGINAL SIGNATURE AND SEAL OR AUTHENTICATED DIGITAL 1.
TWP. 40S., RGE. 42E.
SECTION 36
CENTER STREET
LINE TYPES
R/W LINE
FENCE
OVERHEAD ELECTRICAL
TWP. 40S., RGE. 42E.
SECTION 35
STA. 15+00
END PROJECT
STA. 10+00
BEGIN PROJECT
GOVERNMENT SECTION LINE
BURIED CABLE TELEVISION MARKED BY RITZEL-MASON
BURIED ELECTRIC MARKED BY RITZEL-MASON
BURIED FIBER OPTIC MARKED BY RITZEL-MASON
BURIED UNKNOWN LINE MARKED BY RITZEL-MASON
C R
O W
N
Q
U A
Y
L A
N E
NAVD '88 ELEV + 1.503' = NGVD '29 ELEVATION
NORTH AMERICAN DATUM OF 1988 (NAVD88)
ELEVATIONS SHOWN HEREON ARE BASED ON THE
VERTICAL DATUM
OL
D
DI
XI
E H
IG
H W
AY
W INDIANTOWN RD
N
P
E N
N O
C K
L
N
10'U.E. (P)
(O.R.B.1040, PG.396)
35'D.E.
(O.R.B.1962, PG.1181)
6'U.E.
10 11 12 13 14 15
.0
OF: SV3
24-090
PROJECT NO.
SHEET: SV2
NTS
DR
DD
DR
11/8/24DATE:
CHK'D:
DRAWN:
APP'D:
SCALE:
P A
L M
BE
ACH
Y T
N U
OC
F
LORID
A
ROADWAY PRODUCTION
ENGINEERING AND PUBLIC WORKS
PALM BEACH COUNTY
P.O. BOX 21229, WEST PALM BEACH, FLORIDA
By DateRevisionsNo.
Seal:
PROJECT NO. 2022604
PALM BEACH COUNTY
PALM BEACH COUNTY, FLORIDA
REPLACEMENT
JUPITER PLANTATION DITCH PIPE
TOPOGRAPHIC/SPECIFIC PURPOSE SURVEY
LB8265
Delray Beach, Florida 33484 · 561.634.6701
5119 Beechwood Rd, A SURVEYING AND MAPPING FIRM
RITZEL-MASON INC.
STATE OF
A
DIROL
F
LEZTIR SINNED
E T
ACIFIT
R
E
C r e p p a M dna royevru
S de r et si g e
R
No. 6953
0' 40'
SCALE 1'=40"
20' 80'
SET 5/8" IR&C - RM TRAV PT
ELEV=4.68'
E=946860.775
N=949885.573
O/S=36.40 LT
STA=11+47.11
M100R
SET 5/8" IR&C - RM TRAV PT
ELEV=3.24'
E=946878.526
N=950009.506
O/S=20.83 LT
STA=12+71.34
M101R
SET 5/8" IR&C - RM TRAV PT
ELEV=3.13'
E=946885.531
N=950155.933
O/S=16.39 LT
STA=14+17.87
M102R
(UNABLE TO SET)
E=946894.583
N=949737.845
STA=10+00.00
BEGIN £ OF SURVEY
E=946903.363
N=950237.767
STA=15+00.00
END BASELINE OF SURVEY
N1°00'22"E 500.00'
LANE AS RECORDED IN PLAT BOOK 60, PAGE 164 AND FIELD MONUMENTATION.
HAVING A GRID BEARING OF NORTH 01°00’22” EAST AS CALCULATED FROM THE PLAT OF CROWN QUAY
BEARINGS SHOWN HEREON ARE BASED ON THE WEST RIGHT-OF-WAY LINE OF CROWN QUAY LANE, 3)
DISTANCES ARE GROUND.
= GRID DISTANCE). SCALE FACTOR POINT: N=949988 E=946899. COORDINATES ARE GRID. ALL MERCATOR PROJECTION. PROJECT SCALE FACTOR = 1.000038084 (GROUND DISTANCE X SCALE FACTOR 0901. LINEAR UNITS = US SURVEY FEET. COORDINATE SYSTEM = 1983 STATE PLANE TRANSVERSE
HORIZONTAL DATUM = NAD 1983, 1990 ADJUSTMENT (NAD83/90). ZONE = FLORIDA EAST ZONE 2)
CONCRETE CENNOCK HAVING AN ELEVATION OF 3.226 FEET.
(NAVD88) AND REFERENCE THE FOLLOWING BENCHMARK: PALM BEACH COUNTY BRASS DISC IN
ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 1)
NOTES:
.26'(G
RID)
9.17
'(GROUND)
S56° 54'10
"E
1461.86'(GRID) 1461.80'(GROUND)
S27°09'27"E
E.=946236.112
N.=948937.067
CCR POSITION:
STAMPED "35/36/2/1 PALM BEACH COUNTY GEODETIC SURVEY"
FOUND BRASS DISC IN CONCRETE
36/40/42
S.W. CORNER SECTION
E.=948888.197
N.=948944.001
CCR POSITION:
36/40/42 NOT FOUND
S. QUARTER CORNER SECTION
TWP. 40S., & RGE. 42E.
SEC. 36
NAVD '88 ELEV + 1.503' = NGVD '29 ELEVATION
NORTH AMERICAN DATUM OF 1988 (NAVD88)
ELEVATIONS SHOWN HEREON ARE BASED ON THE
VERTICAL DATUM
CROWN QUAY LANE
(P.B.34, PG.165)
PCN: 30424036130010000
JUPITER PLANTATION FIRST ADDITION
P C
N : 3
S E R V
IC
E A
R E A
R E C
R E A T
IO
N U
T
IL
IT
Y
(P.B. 34, PG.162)
15'D.E.
20' D.E. (O.R.B.1049, PG.398)W. R/W LINE
PROPERTY LINE
N
°5
'0
"E
.0
G
R
ID
.9
G
R O
U N
D
S O
U T
H L
IN
E
O F
S E
C T
IO
N
T
W P
S
R
G E
E
.7
'(G
R O
U N
D
.7
'(G
R
ID
S °2
'4
"E
E=946901.607 N=950137.783
SET 5/8" IR&C "RITZEL-MASON LB 8265"
STA=14+00
E=946898.970 N=949987.807
STA=12+50
SET 5/8" IR&C "RITZEL-MASON LB 8265"
R= (P
R=65' (P)
(NO ID)
FOUND PK-NAIL(NO ID)
FOUND DRILL HOLE IN CURBING
(P
(P
.7
G R
O U
N D
.8
G R
ID
S °1
'1
"E
N01°00'22"E (C)
(PRIVATE) (TRACT "B")
CROWN QUAY LANE
L O
X A
H A T C
H E
E
R
IV
E R
SET 5/8" IR&C - RM TRAV PT
ELEV=3.13'
E=946885.531
N=950155.933
M102R
SET 5/8" IR&C - RM TRAV PT
ELEV=3.24'
E=946878.526
N=950009.506
M101R
SET 5/8" IR&C - RM TRAV PT
ELEV=4.68'
E=946860.775
N=949885.573
M100R
T.W. EL.=2.35'
T.W. EL.=2.10'
T.W. EL.=2.24'
T.W. EL.=2.50'
T.W. EL.=0.00
10'U.E. (P)
E=946898.970
N=949987.807
STA=12+50
SET 5/8" IR&C "RITZEL-MASON LB 8265"
"LB3505"IR&C
FOUND 5/8"
P
P C
N
S E
R V
IC
E A
R E
A
R E
C R
E A T
IO
N U
T
IL
IT
Y
20' D.E. (O.R.B.1049, PG.398)
(P.B. 34, PG.162)
15'D.E.
(O.R.B.1040, PG.396)
35'D.E.
(O.R.B.1962, PG.1181)
6'U.E.
TOP OF TIDAL BAFFLE FLAP EL.=1.61'
INV 48"RCP(S)EL.=-2.39'
SEA WALL OUTFALL
14" WIDE CONCRETE SEA WALL
INV48"RCP(N)EL.=-1.88'
14" WIDE STORM HEADWALL OUTFALL
TOP OF WALL EL.=2.86'
14" WIDE CONCRETE HEADWALL
10 11 12 13 14 15
E L
.0
(9
W A T E
R
E
L E
V A T
IO
N
(UNABLE TO SET)
E=946903.363
N=950237.767
STA=15+00.00
END £ OF SURVEY
N1°00'22"E 500.00'
BASELINE OF SURVEY
.0
TOP OF WALL EL.=2.65'
18" WIDE CONCRETE HEADWALL
SEA WALL
14" WIDE CONCRETE
TOP OF WALL EL.=3.33'
WITH 10" WIDE METAL CAP
SHEETPILE WALL
10" WIDE RIP-RAP HEADWALL
BURIED FOC (4)
BURIED FOC (4)
R (P
R=65' (P)
(P
BURIED CATV (5)
BURIED ELEC (1)
BURIED ELEC (2)
E=946898.970 N=949987.807
STA=12+50
SET 5/8" IR&C "RITZEL-MASON LB 8265"
(NO ID)
FOUND DRILL HOLE
(NO ID)
FOUND PK-NAIL
(UNABLE TO SET)
E=946894.583 N=949737.845
STA=10+00.00
BEGIN £ OF SURVEY
T.W. EL.=-0.10'
T.W. EL.=1.40'
T.W. EL.=2.10'
T.W. EL.=2.45'
(Q L B (2
U T
IL
IT
Y
U N
K N
O W
N
-2 .4 9'
-2 .4 1'-1
.3 0'
3.
-1 .9 4' -2
.4 5'
-3 .5 8'
5.
3.
-2 .7 1'
-0 .6 5'
-6 .6 2'
3.
4.
3.
-1 .8 8'
2.
-2 .7 0'
3.
3.
-1 .0 8'
0.
-2 .0 1'
-1 .9 2'
1.
2.
-0 .6 6'
0.
4.
3.
-0 .2 5'
-2 .5 2'
3.
4.
'4.
3.
4.
T.W. EL.=1.00'
(P.B.34, PG.165)
PCN: 30424036130010000
JUPITER PLANTATION FIRST ADDITION
(O.R.B.5860, PG.1482)
PCN: 00424036170000080
(P.B.60, PG.164)
CROWN QUAY LANE
LOT 8
-1 .8 0'
4.
GRASS
±308' (P)4' C.L. FENCE
FFE= 6.22'
BUILDING
GRASS
SWALE
DITCH
GRASS
24" PA
10" UNK (2)
15" UNK
18" PA
17" UNK
6" PI (2)
10" PA
15" PA
P A
8" PI
5" PIW. R/W LINE
PROPERTY LINE
GARAGE FFE= 6.17'
BUILDING
DRIVEWAY
CONCRETE
18" UNK
16" UNK(2)
21" UNK (2)
ESTABLISHED PROPERTY LINES AND BASELINE.
LIMITS. FIELD MONUMENTATION WAS USED TO
MONUMENTATION FOUND SOUTH OF PROJECT
NOTE: 9 ADDITIONAL PROPERTY AND RIGHT-OF-WAY
12" UNK
26" UNK
OF: SV3
24-090
PROJECT NO.
SHEET: SV3
NTS
DR
DD
DR
11/8/24DATE:
CHK'D:
DRAWN:
APP'D:
SCALE:
PA
L
M
BE
ACH
Y T
N U
OC
F
LORID
A
ROADWAY PRODUCTION
ENGINEERING AND PUBLIC WORKS
PALM BEACH COUNTY
P.O. BOX 21229, WEST PALM BEACH, FLORIDA
By DateRevisionsNo.Seal:
PROJECT NO. 2022604
PALM BEACH COUNTY
PALM BEACH COUNTY, FLORIDA
REPLACEMENT
JUPITER PLANTATION DITCH PIPE
TOPOGRAPHIC/SPECIFIC PURPOSE SURVEY
LB8265
Delray Beach, Florida 33484 · 561.634.6701
5119 Beechwood Rd, A SURVEYING AND MAPPING FIRM
RITZEL-MASON INC.
STATE OF
A
DIROL
F
LEZTIR SINNED
E T
ACIFIT
R
E
C r e p p a M dna royevru
S de r et si g e
R
No. 6953
0' 40'
SCALE 1'=40"
20' 80'
N.=948944.001, E.=948888.197
CCR POSITION:
36/40/42 NOT FOUND
S. QUARTER CORNER SECTION
N
°5
'0
"E
.0
G
R
ID
.9
G
R O
U N
D
S O
U T
H L
IN
E
O F
S E
C T
IO
N
T
W P
S
R
G E
E
.7
G R
O U
N D
.8
G R
ID
S °1
'1
"E
.7
'(G
R O
U N
D
.7
'(G
R
ID
S °2
'4
"E
.26'(G
RID)
9.17
'(GROUND)
S56° 54'10
"E
1461.86'(GRID) 1461.80'(GROUND)
S27°09'27"E
E.=946236.112
N.=948937.067
CCR POSITION:
STAMPED "35/36/2/1 PALM BEACH COUNTY GEODETIC SURVEY"
FOUND BRASS DISC IN CONCRETE
36/40/42
S.W. CORNER SECTION
NAVD '88 ELEV + 1.503' = NGVD '29 ELEVATION
NORTH AMERICAN DATUM OF 1988 (NAVD88)
ELEVATIONS SHOWN HEREON ARE BASED ON THE
VERTICAL DATUM
| SURVRD01_sht1 |
| SURVRD01_sht2 |
| SURVRD01_sht3 |
| 2024-12-16T13:50:20-0500 | |
| Dennis A Ritzel |
File details come from the government source that posted it. Updated .