John Yeates MS - Bid.pdf

PDF 9 MB Posted

Attached to
John Yeates Middle School Ceiling and Lighting
Solicitation number
49261
Issued by
Suffolk City, Virginia

About this file

This document is the bid package for the John Yeates Middle School Ceiling and Lighting project solicited by Suffolk Public Schools in Suffolk, Virginia. The project involves the demolition and replacement of the ceilings and lighting fixtures throughout the various areas of the middle school building. The bid package includes detailed demolition and new work plans for each area of the school, as well as an electrical legend, abbreviations, and general notes. Bidders are required to provide pricing for the specified light fixtures, ceiling grid, and auxiliary system installations. The bid due date is July 19, 2023, and the project is expected to be awarded shortly thereafter. The contract term and any renewal options are not specified in the provided documents.

The bid package does not include any information about pricing terms, set-asides, incumbent contractors, funding sources, or other financial details. It focuses solely on the technical requirements and scope of work for the ceiling and lighting replacement project at John Yeates Middle School in Suffolk, Virginia.

View the file

Other files

File Type Posted
000100 - IFB 1821 JYMS.pdf PDF
JYMS Add 3.pdf PDF
JYMS Ceiling and Lighting - Bidding - Project Manual.pdf PDF
JYMS Addendum No. 1.pdf PDF
JYMS Pre-bid sign in.pdf PDF
JYMS Addendum2.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JOHN YEATES MIDDLE SCHOOL

SUFFOLK PUBLIC SCHOOLS

RRMM ARCHITECTS, PC

ARCHITECTURE / PLANNING / INTERIORS

VICINITY MAP CONSULTANTS OWNER LOCATION MAP

THOMPSON CONSULTING ENGINEERING

MEP ENGINEERING

22 Enterprise Parkway, Suite 200

Hampton, VA 23666 P: (757) 599-4415

F: (757) 599-4113

SUFFOLK CITY PUBLIC SCHOOLS

1507 Freeney Street

Suffolk, VA 23434

P: (757) 934-6206 F: (757) 274-0679

SITE

SITE

1317 Executive Boulevard, Suite 200 Chesapeake, VA 23320

(757) 622-2828

28 Church Avenue SW Roanoke, VA 24011

(540) 344-1212

1 Research Court, Suite 450 Rockville, MD 20850

(240) 403-4101

2900 South Quincy Street, Suite 710 Arlington, VA 22206

(703) 998-0101

115 South 15th Street, Suite 202 Richmond, VA 23219

(804) 277-8987

CEILING AND LIGHTING REPLACEMENT

SHEET INDEX

Lic. No. 10748

JEFFREY A HARRIS

T

T E C

IH

C

R

A

C

T

O M M O

N W E

A L FO

H

A N I

G I

R

I V

RRMM

ARCHITECTS, PC

1317 Executive Blvd, Suite 200

D A

T E

D R

A W

N

P R

O J E

C T

D E

S

IG

N E

D

C H

E C

K E

D

Chesapeake, Virginia 23320 (757)622-2828

M A

R K

R E

V

IS

IO

N

S

D A

T E

B Y

D E

S C

R

IP

T

IO

N

0' 16' 32' 48'

1/32" = 1'-0"

0' 8' 16' 24'

1/16" = 1'-0"

4' 0' 4' 8' 16'

3/32 = 1'-0"

0' 4' 8' 12'

1/8" = 1'-0"

0' 2' 4' 6'

1/4" = 1'-0"

0' 1' 2' 4'

3/8" = 1'-0"

3' 0' 1' 2' 3'

1/2" = 1'-0"

6" 0' 1' 2'

3/4" = 1'-0"

6" 0' 6" 1' 1.5'

1" = 1'-0"

3" 9" 0' 3" 6" 1'

1 1/2" = 1'-0"

9" 0' 2" 4" 6"

3" = 1'-0"

5"3"1" 0' 1" 2" 3"

6" = 1'-0"

0' 1" 1.5"

12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

P R

O J E

C T

D R

A W

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

06-07-2023

/1

/2

:3

:1

P

M A u to d e s k D o c s /2

-1

S

P S

L a k e la n d H

S P h a s e

/2

-1 v

L a k e la n d

H S

I n te ri o r

R e n o

P h a s e

A R

C H

.r v t

T001

-0

-2

-1

J A

H

M F

W

J A

H

T

IT

L E

S H

E E

T

S U

F F

O L

K P

U B

L

IC

S C

H O

O L S

J O

H N

Y E

A T

E S

M

ID

D L

E S

C H

O O

L

B

E N

N E

T T

S P

A S

T U

R E

R O

A D

S U

F F

O L K

V

IR

G

IN

IA

Sheet Number Sheet Title

PROJECT TITLE SHEET

T001 TITLE SHEET

ELECTRICAL

E001 ELECTRICAL LEGEND, ABBREVIATIONS, AND NOTES

E002 ELECTRICAL AND MECHANICAL DETAILS

CPD101 FLOOR PLAN - AREA A - REFLECTED CEILING - DEMOLITION

CPD102 FLOOR PLAN - AREA B - REFLECTED CEILING - DEMOLITION

CPD103 FLOOR PLAN - AREA C - REFLECTED CEILING - DEMOLITION

CPD104 FLOOR PLAN - AREA D - REFLECTED CEILING - DEMOLITION

ED101 FLOOR PLAN - AREA A - LIGHTING - DEMOLITION

Sheet Number Sheet Title

ED102 FLOOR PLAN - AREA B - LIGHTING - DEMOLITION

ED103 FLOOR PLAN - AREA C - LIGHTING - DEMOLITION

ED104 FLOOR PLAN - AREA D - LIGHTING - DEMOLITION

CP101 FLOOR PLAN - AREA A - REFLECTED CEILING - NEW WORK

CP102 FLOOR PLAN - AREA B - REFLECTED CEILING - NEW WORK

CP103 FLOOR PLAN - AREA C - REFLECTED CEILING - NEW WORK

CP104 FLOOR PLAN - AREA D - REFLECTED CEILING - NEW WORK

E101 FLOOR PLAN - AREA A - LIGHTING - NEW WORK

E102 FLOOR PLAN - AREA B - LIGHTING - NEW WORK

E103 FLOOR PLAN - AREA C - LIGHTING - NEW WORK

E104 FLOOR PLAN - AREA D - LIGHTING - NEW WORK

RRMM

ARCHITECTS, PC

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

E001

EL

EC

TR

IC

AL

L

EG

EN

D , A

BB

R

EV

IA

TI

O

N S

AN

D

N O

TE

S

ELECTRICAL LEGEND:

TELECOMMUNICATION SYSTEM:

FIRE ALARM SYSTEM:

INTERCOM SYSTEM:

INTRUSION DETECTION SYSTEM:

CCTV SYSTEM:

EXISTING CEILING MOUNTED NETWORK WIRELESS

ACCESS POINT.

EXISTING CEILING MOUNTED MOTION DETECTOR.

EXISTING CEILING MOUNTED SPEAKER.

EXISTING SMOKE DETECTOR.

EXISTING INTERIOR CEILING MOUNTED CCTV CAMERA.

S

S

MD

WA

EXISTING MECHANICAL DIFFUSER

EXISTING HEATING, VENTILATION,

AIR CONDITIONING UNIT, CEILING MOUNTED.

EXISTING EXHAUST FAN.

EXISTING LITTLE FAN.

EXISTING BIGGER FAN.

MECHANICAL LEGEND

1. WHERE EXISTING INDIVIDUAL 120V HOMERUN CIRCUITS ARE SHOWN ON THE

DRAWINGS THEY MAY BE COMBINED AS FOLLOWS:

NO MORE THAN THREE (3) PHASE CONDUCTOR PLUS THREE NEUTRALS AND

ONE (1) GROUND PER CONDUIT, EXCEPT WHERE SPECIFICALLY NOTED

OTHERWISE.

NO TWO OF THE SAME PHASE CONDUCTOR PER CONDUIT.

PROVIDE 120V CIRCUIT WITH INDIVIDUAL NEUTRALS PER CIRCUIT. NEUTRALS

MAY NOT BE SHARED BETWEEN PHASES.

2. PAINT ALL EXPOSED CONDUIT AND SURFACE METAL RACEWAY TO MATCH THE

SURFACE TO WHICH ATTACHED IF THE SURFACE IS PAINTED.

3. PROTECT BRANCH CIRCUIT WIRING FROM PAINT OVERSPRAY DURING

CONSTRUCTION TO PRESERVE COLOR-CODING. CONDUCTORS PAINTED SHALL BE

COMPLETELY CLEANED OF PAINT BEFORE FINAL CONNECTIONS ARE MADE.

4. VERIFY OUTLET BOX, DEVICE AND WIRING REQUIREMENTS FOR INTERCOM STATIONS,

SPEAKERS AND FIRE ALARM DEVICES WITH THE EXISTING SYSTEM MANUFACTURER'S

AND PROVIDE ALL MATERIAL AND LABOR REQUIRED TO EXTEND THE EXISTING

SYSTEMS (FOR ADDITION/RENOVATION PROJECTS ONLY).

5. COORDINATE WIRING DEVICE OUTLET LOCATIONS WITH ARCHITECTURAL PLANS,

ELECTRICAL PLANS, ENLARGED FLOOR PLANS, EQUIPMENT AND FURNITURE

LAYOUTS, SECTIONS, ELEVATIONS, DETAILS AND JOB SITE DIFFERENCES PRIOR TO

ROUGHING-IN CONDUITS. MAKE REQUIRED ADJUSTMENTS WITH ARCHITECTS AND

ENGINEERS APPROVAL).

6. INSTALL DEVICES SHOWN ON DRAWINGS IN ACCORDANCE WITH MOUNTING HEIGHTS

SHOWN IN THE ELECTRICAL LEGEND AND/OR THE PROJECT SPECIFICATIONS. ALL

MOUNTING HEIGHT DIMENSIONS ARE TO THE BOTTOM OF THE OUTLET BOX, UNLESS

OTHERWISE NOTED.

7. WHERE THE TERM "BRANCH CIRCUITRY" IS USED ON THESE DRAWINGS, IT IS TO BE

CONSTRUED TO MEAN CONDUIT AND CONDUCTORS.

8. TYPE “MC” CABLE IS NOT ALLOWED TO BE INSTALLED ON THIS PROJECT.

9. THE CONTRACTOR SHALL PROVIDE TOTAL NUMBER OF ALL LIGHT FIXTURES THAT IS

TO BE REMOVED AND TURN OVER TO OWNER, UNLESS OTHER WISED INSTRUCTED

BY OWNER.

12. WHERE THE EXISTING CEILINGS ARE BEING REMOVED UNDER DEMOLITION AND

REPLACED WITH NEW CEILING, CONTRACTOR SHALL MAKE THEMSELVES AWARE OF

ALL EXISTING CEILING ELEVATION HEIGHTS AND MAINTAIN THIS ELEVATION HEIGHT

FOR THE NEW CEILING.

13. PROVIDE A TYPED CIRCUIT INDEX CARD FOR EACH PANELBOARD UPON COMPLETION

OF INSTALLATION WORK. INDICATE LOAD SERVED AND ROOM NUMBER(S). USE

FINAL ROOM NUMBERS OBTAINED FROM THE ARCHITECT OR OWNER, NOT

CONSTRUCTION ROOM NUMBERS AS SHOWN ON THE DRAWINGS.

14. WHERE THE EXISTING CEILINGS ARE BEING REMOVED UNDER DEMOLITION AND

REPLACED WITH NEW CEILING, CONTRACTOR SHALL MAKE THEMSELVES AWARE OF

ALL EXISTING CEILING ELEVATION HEIGHTS AND MAINTAIN THIS ELEVATION HEIGHT

FOR THE NEW CEILING.

15. RECESSED LIGHT FIXTURES SHALL BE SUPPORTED WITH INDIVIDUAL ANNEALED,

LIGHT ZINC-COATED FINISH, 12-GAUGE WIRE FROM ALL FOUR CORNERS TIED TO

BUILDING STRUCTURAL MEMBERS. SECURE SAFETY WIRES TO BRIDGING IS NOT

ACCEPTABLE. THE SUPPORTING WIRES SHALL BE DISTINGUISHABLE BY COLOR OR

TAGGING. PROVIDE ROD HANGERS CAPABLE OF SUPPORTING TWICE THE WEIGHT

OF THE LIGHT FIXTURE SUPPORTED BY THE ROD HANGER FOR ALL SURFACE

MOUNTED LIGHT FIXTURES. ROD HANGERS SHALL BE A MINIMUM 1/4” DIAMETER.

GENERAL NOTES:

1. PERFORM ALL REQUIRED DEMOLITION TO COMPLY WITH THE SCOPE AND INTENT OF THE PROJECT. RETAIN MUCH OF THE

WIRING ASSOCIATED WITH THE REQUIRED DEMOLITION FOR REUSE.

2. VERIFY ALL CIRCUITS SAVED DURING DEMOLITION FOR REUSE AS TO WIRE SIZE AND POINT OF ORIGIN.

3. EXERCISE CARE IN REMOVING MATERIAL AND EQUIPMENT DURING DEMOLITION. REPAIR ALL DAMAGE TO EXISTING SURFACES OR EXISTING EQUIPMENT TO REMAIN TO THE SATISFACTION OF THE ARCHITECT AND OWNER AT NO ADDITIONAL

COST TO THE OWNER.

4. PROVIDE THE OWNER WITH FIRST RIGHT OF REFUSAL FOR ALL ELECTRICAL EQUIPMENT BEING REMOVED AS A PART OF THIS CONTRACT AND NOT SCHEDULED FOR REINSTALLATION. ALL ELECTRICAL EQUIPMENT NOT TURNED OVER TO THE OWNER SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE REMOVED FROM THE SITE.

5. FLUORESCENT BALLASTS IN EXISTING LIGHT FIXTURES SCHEDULED TO BE REMOVED MAY CONTAIN PCB'S. REMOVE THE BALLASTS FROM THE LIGHT FIXTURES, PROPERLY CONTAIN AND DISPOSE OF SAME IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS GOVERNING SAME.

6. FLUORESCENT LAMPS IN EXISTING LIGHT FIXTURES SCHEDULED TO BE REMOVED MAY CONTAIN MERCURY. REMOVE THE LAMPS FROM THE LIGHT FIXTURES, PROPERLY CONTAIN AND DISPOSE OF SAME IN ACCORDANCE WITH ALL FEDERAL, STATE

AND LOCAL REGULATIONS GOVERNING SAME.

7. BEFORE BEGINNING ANY WORK, FIELD VERIFY THE WORKING CONDITION OF ALL AUXILIARY SYSTEM DEVICES SCHEDULED FOR REMOVAL AND REINSTALLATION. NOTIFY THE OWNER OF ALL DEFECTIVE EQUIPMENT. AFTER THE REINSTALLATION OF ALL EQUIPMENT, RE-VERIFY THE WORKING CONDITION. REPLACE ALL EQUIPMENT FOUND DEFECTIVE AFTER REINSTALLATION, WHICH WERE WORKING PRIOR TO REMOVAL WITH EQUIPMENT TO MATCH EXISTING AT NO ADDITIONAL

COST TO THE OWNER.

8. DURING THE REMOVAL OF EXISTING CEILINGS, SUPPORT ALL EXISTING AUXILIARY SYSTEMS CABLES (DATA, INTERCOM, TELEPHONE, TELEVISION, CCTV, ETC.) FROM STRUCTURE ABOVE EXISTING CEILING. ADJUST ROUTING OF THESE CABLES TO ACCOMMODATE THE INSTALLATION OF EXISTING HVAC SYSTEM EQUIPMENT. RE-VERIFY THE WORKING CONDITION OF THESE CABLES AND REPLACE ALL CABLES FOUND DEFECTIVE AFTER REINSTALLATION, WHICH WERE WORKING PRIOR TO REMOVAL

WITH CABLES TO MATCH EXISTING AT NO ADDITIONAL COST TO THE OWNER.

9. IN AREAS WHERE NO OTHER TRADES ARE INVOLVED, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL OF EXISTING CEILING TILES AS REQUIRED TO INSTALL NEW BRANCH CIRCUITRY. CONTRACTOR SHALL INSTALL NEW CEILING TILES AFTER COMPLETION OF WORK. REPLACE ANY CEILING TILES DAMAGED DURING THIS PROJECT WITH NEW TILES TO THE

SATISFACTION OF THE ARCHITECT AND OWNER.

10. PROVIDE ALL ELECTRICAL DEMOLITION WORK NECESSARY TO INSTALL NEW WORK. REROUTE AND RECONNECT ALL CIRCUIT

THAT IS REQUIRED TO REMAIN IN USE BUT INTERFERES WITH NEW CONSTRUCTION.

11. CONDUITS MAY BE ABANDONED IN WALLS AND BELOW FIRST FLOOR SLABS ONLY. REMOVE ALL WIRING FROM ABANDONED CONDUITS. DISCONNECT CONDUCTORS FROM ALL POWER SOURCES AND PROVIDE BLANK COVERPLATES ON ALL

ABANDONED OUTLET BOXES.

12. WHERE THE TERM "BRANCH CIRCUITRY" IS USED ON THESE DRAWINGS, IT IS TO BE CONSTRUED TO MEAN CONDUIT AND

CONDUCTORS.

13. PROVIDE NEW TYPED PANEL INDEX CARDS IN EXISTING PANELBOARDS WHERE CIRCUITS HAVE BEEN MODIFIED BY THIS PROJECT. PROVIDE COPIES OF MODIFIED PANEL INDEX CARDS ON AS BUILT DRAWINGS AND INCLUDED IN OPERATION AND MAINTENANCE MANUALS. PROVIDE CIRCUIT BREAKER FILLER PLATES FOR ALL CIRCUIT BREAKERS REMOVED FROM EXISTING

PANELBOARDS DURING DEMOLITION WORK.

14. EXISTING CONDITIONS ILLUSTRATED HAVE BEEN DETERMINED FROM ORIGINAL CONSTRUCTION DOCUMENTS AND LIMITED NON-INVASIVE FIELD INVESTIGATION. CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR TO COMMENCEMENT OF

WORK, COORDINATE AND MAKE ADJUSTMENTS AS NECESSARY.

GENERAL DEMOLITION NOTES

HL

EXISTING 2 'X 4' LIGHT FIXTURE

EXISTING 1' X 1' LIGHT FIXTURE.

EXISTING 1' X 4' LIGHT FIXTURE.

EXISTING 6" DOWNLIGHT.

EXISTING EMERGENCY LIGHT FIXTURE WITH SELF-CONTAINED BATTERY PACK.

NEW 2' X 4' LED LIGHT FIXTURE . NUMBER SUBSCRIPT INDICATES LIGHT

FIXTURE TYPE.

NEW 2' X 4' LED LIGHT FIXTURE WITH SELF CONTAINED EMERGENCY BATTERY

PACK. NUMBER SUBSCRIPT INDICATES LIGHT FIXTURE TYPE. SUBSCRIPT "NL"

WHEN USED INDICATE A NIGH LIGHT (ALWAYS ON) LIGHT FIXTURE.

NEW 2' X 2' LED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES LIGHT

FIXTURE TYPE.

NEW 2' X 2' LED LIGHT FIXTURE WITH SELF CONTAINED EMERGENCY BATTERY

PACK. NUMBER SUBSCRIPT INDICATES LIGHT FIXTURE TYPE. SUBSCRIPT "NL"

WHEN USED INDICATE A NIGH LIGHT (ALWAYS ON) LIGHT FIXTURE.

NEW 1' X 4' LED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES LIGHT

FIXTURE TYPE.

NEW 1' X 4' LED LIGHT FIXTURE WITH SELF CONTAINED EMERGENCY BATTERY

PACK. NUMBER SUBSCRIPT INDICATES LIGHT FIXTURE TYPE.

NEW CEILING MOUNTED EXIT LIGHT WITH DIRECTIONAL ARROWS AS

INDICATED. SHADED AREA INDICATES FACE-LIT. NUMBER SUBSCRIPT

INDICATES LIGHT FIXTURE TYPE.

NEW SURFACE MOUNTED LIGHT FIXTURE WITH SELF-CONTAINED BATTERY

PACK, CONNECT AHEAD OF ANY LOCAL SWITCHING. NUMBER SUBSCRIPT

INDICATES LIGHT FIXTURE TYPE.

NEW SURFACE MOUNTED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES

LIGHT FIXTURE TYPE.

NEW HIGH BAY LED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES LIGHT

FIXTURE TYPE.

NEW HIGH BAY LED LIGHT FIXTURE WITH SELF CONTAINED EMERGENCY

BATTERY PACK.

NEW SINGLE POLE SWITCH, 20A, 120/277V, AC. INSTALL +46" A.F.F., U.O.N.

SUBSCRIPT "W", WHEN USED, INDICATES DEVICE IN WIREMOLD SURFACE

NON-METALLIC OUTLET BOX.

EXISTING SINGLE POLE SWITCH, 20A, 120/277V, AC.

EXISTING THREE-WAY SWITCH, 20A, 120/277V, AC.

NEW SINGLE POLE SWITCH WITH OCCUPANCY SENSOR; SENSOR SWITCH

CATALOG # WSD-PDT. INSTALL IN EXISTING OUTLET BOX SAVED DURING

DEMOLITION.

NEW SINGLE POLE DIMMER SWITCH WITH OCCUPANCY SENSOR; SENSOR

SWITCH CATALOG # WSD-D. INSTALL IN EXISTING OUTLET BOX SAVED DURING

DEMOLITION.

NEW LOW VOLTAGE HIGH BAY OCCUPANCY SENSOR; SENSOR SWITCH

CATALOG # CM-6, OR APPROVED EQUAL. INSTALL ON CEILING WHERE

INDICATED ON PLANS. SEE "LOW VOLTAGE OCCUPANCY SENSOR DIAGRAM"

ON DRAWING E-002.

NEW CEILING MOUNTED LINE VOLTAGE OCCUPANCY SENSOR - PROVIDE

SENSOR SWITCH CATALOG # CMR-PDT-10 OR APPROVED EQUAL.

NEW 2 POLE OCCUPANCY SENSOR POWER PACK; SENSOR SWITCH CATALOG #

2-PP-20 SERIES, OR APPROVED EQUAL. INSTALL IN JUNCTION BOX ABOVE

CEILING, U.O.N.

DEMOLITION NOTE INDICATOR.

NEW WORK NOTE INDICATOR.

SW

SOSD

OS

OS

PP

ARCHITECTURAL LEGEND

BULKHEAD

CEILING

ELEVATION

BLKHD

CLG

ELEV

ABBREVIATIONS

AC ALTERNATING CURRENT

ACP ACOUSTICAL CEILING PANEL

ADA AMERICANS WITH DISABILITIES ACT

A.F.F. ABOVE FINISHED FLOOR

A.F.G. ABOVE FINISHED GRADE

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

ATS AUTOMATIC TRANSFER SWITCH

C CONDUIT

C.B. CIRCUIT BREAKER

CIRC/CKT CIRCUIT

E EXISTING

EF EXHAUST FAN

EM EMERGENCY

LED LIGHT EMITTING DIODE

NEMA NATIONAL ELECTRICAL MANUFACTURE ASSOCIATION

N.E.C. NATIONAL ELECTRICAL CODE

NO. NUMBER

N.T.S. NOT TO SCALE

PNL PANEL

TYP TYPICAL

U.O.N. UNLESS OTHERWISE NOTED

V VOLT

DAY-BRITE CFI

TGS CONTOUR TROFFER UNV

LIGHT FIXTURE SCHEDULE

TYPE MANUFACTURER'S CATALOG No. VOLT MOUNTING REMARKS

1 RECESSED

DAY-BRITE CFI

LIGHT FIXTURE SCHEDULE NOTES

1. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS. SHADING INDICATES NUMBER OF FACES LIT.

2. HOUSING COLOR TO BE SELECTED BY ARCHITECT.

3. PROVIDE WITH EMERGENCY BATTERY BACKUP OPTION.

4. PROVIDE PENDANT LENGTH AS REQUIRED TO INSTALL THE LIGHT FIXTURE AT THE SAME HEIGHT AS ORIGINAL TO THE BOTTOM OF FIXTURE. PROVIDE UNISTRUT CHANNEL TO SPAN UNDERSIDE OF TOP CHORD OF JOIST

TO SUSPEND LIGHT FIXTURE. PROVIDE LIGHT FIXTURE WITH A WIRE GUARD.

LEDALITE-TRUGROVE SURFACE

RECESSED

RECESSED

LAMPS

NOT USED

LEDALITE-TRUGROVE5 SURFACE

NOT USED

TGS THINTEK G2 RECESSED

DAY-BRITE CFI

TGS THINTEK G29 RECESSED

PEERLESS

MERCURY LIGHTING SURFACE

PENDANT

SURFACE

13 MERCURY LIGHTING

DAY-BRITE CFI PENDANT

SURFACE

LED

UNV

UNV

UNV

UNV

UNV

UNV

UNV

UNV

UNV

UNV

UNV

CT-24-WS35-C3500K-U

2SBP3550L8CS-4-UNV-DIM

2SBP3550L8CS-4-UNV-DIM-GTD

29-1-1-L-935-30-QN-08-D-E-1-N-G-SF

29-1-1-L-935-30-QN-08-D-E-1-N-SF

88-24-40-35-T-F-80-RM

88-24-40-35-T-F-80-RM-GTD

AMH-WA-4-40-35K-WM

RBX-20L-835-UNV-WT-ARR165-GTD-WGA22

LW45-4-4500-35K-HTA-1%-UNI

LW45-4-4500-35K-HTA-1%-UNI-GTD-WGA22

RBX-20L-835-UNV-WT-ARR165-WGA22

NOT USED

TGS CONTOUR TROFFER UNV15 RECESSED

NOT USED

TGS THINTEK G2 RECESSED

PEERLESS-PEERLUX

TGS THINTEK G219 RECESSED

PEERLESS-PEERLUX SURFACE

SURFACE

UNV

UNV

UNV

UNV

CT-24-WS35-C3500K-U-GTD

88-22-40-35-T-F-RM-GTD

AHM-WA-4-30-35K-WM

88-22-40-35-T-F-RM

AHM-WA-4-30-35K-WM-GTD

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

LED

CHLORIDE SURFACEUNVVERWEM LED

LUMENS WATTAGE

4400 48

4570 38.3

4570 38.3

3192 32.9

3192 32.9

4486 40.4

4486 40.4

3028 22.8

20366 157.9

4440 48

4440 48

20366 157.9

4400 48

4400 40

4400 40

3080 22.8

3080 22.8

270 3

SEE NOTES 2,3

SEE NOTE 1

SEE NOTE 2

DAY-BRITE CFI SURFACEUNVV2-W-A-70L-835-8-UNV-TBK LED6985 65.3

DAY-BRITE CFI SURFACEUNVV2-W-A-70L-835-8-UNV-TBK-GTD LED6985 65.3

SE

SOS

S3

SEE NOTE 3

SEE NOTE 3

SEE NOTES 3,4

SEE NOTES 3,4

SEE NOTE 3

SEE NOTE 3

SEE NOTE 3

SEE NOTE 3

NL

NL

-1

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

E002

EL

EC

TR

IC

AL

A

N D

M

EC

H

AN

IC

AL

D

ET

AI

LS

OS OS

TYPICAL LINE VOLTAGE OCCUPANCY SENSOR WIRING DIAGRAM

LIGHT SWITCH(ES)

RED

BLUE

BLACK

NOT TO SCALE

NOTES:

LED DRIVER

PROVIDE LINE VOLTAGE OCCUPANCY SENSOR. INSTALL ON CEILING WHERE INDICATED ON PLANS.

BRN

BLACK

RED

BRN

BLACK

RED

LIGHT FIXTURE WITH LED DRIVER.

OS

PP

GYM LOW VOLTAGE OCCUPANCY SENSOR

WIRING DIAGRAM

RED

BLUE

BLACK

PHASE

NEUTRAL

GROUND

Ø

Ø

NEUTRAL

Ø

NOT TO SCALE

NOTES:

PROVIDE 2 POLE POWER PACK; SENSOR SWITCH CATALOG NUMBER 2PP-20 SERIES, OR EQUAL.

PROVIDE LOW VOLTAGE HIGH BAY OCCUPANCY SENSOR; SENSOR SWITCH CATALOG NUMBER CM-6 OR

EQUAL. INSTALL WHERE INDICATED ON PLANS.

BRN

BLACK

RED

HL HLOS

LED DRIVER LED DRIVER

HANGER WIRE TO STRUCTURE

RECTANGULAR TO ROUND

EXPANDED SIDE TAKE-OFF WITH

DAMPER IN BRANCH EXTERNAL

INSULATION ON SHEET METAL

STRAIGHT DUCT OR PROVIDE

EQUALIZING GRID AT DIFFUSER

DIA.

DUCT HANGER, SIZED PER DUCT

PREINSULATED FLEXIBLE DUCT

FLEXIBLE DUCT SECURED WITH

MECHANICAL BAND CLAMPS,

USE FOIL BACKED TAPE TO

TRANSITION TO FLEXIBLE DUCT

INSULATION

(TYPICAL ALL FLEXIBLE DUCTS)

INSULATION OVERLAPPING

DIFFUSER COLLAR

FINISHED CEILING SUPPORT

SUPPLY AIR DIFFUSER FACE OR

OTHER

CEILING DIFFUSER INSTALLATION DETAIL

NOT TO SCALE

NOTES:

THE RE-INSTALLATION OF THE NEW DIFFUSERS SHALL BE PLACED IN KIND IN

LOCATION OF THOSE EXISTING. WHERE DIFFUSERS ARE LOCATED IN ANOTHER

SPACE, THE MECHANICAL CONTRACTOR SHALL EXTEND THE FLEXIBLE CONNECTION

TO NEW LOCATION.

1 1

2 2

2 2

FOOTCANDLE SCHEDULE

ROOM DESCRIPTION MINIMUM MAINTAINED

FOOTCANDLES

CLASSROOM 50-60

CORRIDOR 20-30

TOILET

CAFETERIA

LIBRARY 20-100

OFFICE 30-50

20-30

50-60

AUDITORIUM 60-70

KITCHEN 50-100

PHASE

NEUTRAL

GROUND

EXISTING GYM PANEL

EMERGENCY BATTERY BACKUP

11 14

EMERGENCY BATTERY

BACKUP, TYPICAL

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

CPD101

FL

O

O R

P

LA

N

AR

EA

A

R

EF

LE

C

TE

D

C

EI

LI

N

G

D

EM

O

LI

TI

O

N

FLOOR PLAN - AREA A - REFLECTED CEILING - DEMOLITION

SCALE: 1/8" = 1'-0"

WA

WA

WA

WA

WA

M

AT

C H

LI

N

E A

M

AT

C H

LI

N

E B

MATC

HLIN

E A

MATC

HLIN

E C

S

S

S

S

S

S

S

S

S

S S

S S

S

S

S

S

S

S

E

ROOM 23

ROOM 21

ROOM 48

ROOM 29

ROOM 39

ROOM

ROOM 38 ROOM 47

ROOM 36 ROOM 45

ROOM 34 ROOM 43

ROOM 32 ROOM 41

ROOM 46

ROOM 44

ROOM 42

ROOM

ROOM

CLINIC

GIRLS ROOM

BOYS ROOM

STORAGE

STORAGE

ROOM 20

STORAGE

ROOM

STORAGE

FOR

RM 30 & 40

WA

WA

WA WA

WA WA

WA

WA

WAWA

ROOM 27

ROOM 26

ROOM 25

ROOM 24

GIRLS

ROOM

BOYS

ROOM

S

CUSTODIAN

ROOM

XFMR

ROOM

STOR

ROOM

ROOM 33

ROOM 35

ROOM 37

S S S S

S

S

S

S

S

S

S

S

S

WA

S

S

WA

S

2 'X 4' LIGHT FIXTURE

2 'X 4' LIGHT FIXTURE [WITH SELF CONTAINED EMERGENCY

BATTERY PACK

2' X 2' LIGHT FIXTURE

2' X 2' LIGHT FIXTURE [WITH SELF CONTAINED EMERGENCY

BATTERY PACK

1' X 1' LIGHT FIXTURE

1' X 4' LIGHT FIXTURE

1' X 4' LIGHT FIXTURE [WITH SELF CONTAINED EMERGENCY

BATTERY PACK

RECESSED DOWNLIGHT

RECESSED DOWNLIGHT WITH SELF CONTAINED EMERGENCY

BATTERY PACK

EMERGENCY LIGHT FIXTURE WITH SELF-CONTAINED BATTERY

PACK

CEILING MOUNTED EXIT LIGHT

MECHANICAL DIFFUSER

HEATING, VENTILATION, AIR CONDITIONING UNIT, CEILING

MOUNTED

EXHAUST FAN

CEILING MOUNTED LITTLE FAN

CEILING MOUNTED BIGGER FAN

INTERIOR CEILING MOUNTED CCTV CAMERA

SMOKE DETECTOR

CEILING MOUNTED SPEAKER

CEILING MOUNTED MOTION DETECTOR

CEILING MOUNTED WIRELESS ACCESS DATA OUTLET

NEW BULKHEAD, SEE DRAWINGS FOR FURTHER INFORMATION

EXISTING CORRIDOR GATE

EXISTING GYPSUM BOARD CEILING

NEW CEILING GRID 24" X 24"

EXISTING CEILING GRID 48" X 24"

EXISTING SPACES WITH NO CEILING, STRUCTURE IS EXPOSED.

REFLECTED CEILING PLAN LEGEND:

EF

S

S

MD

WA

GENERAL DEMOLITION AND NEW WORK NOTES:

THE CONTRACTOR SHALL FIELD VERIFY ALL REFLECTED CEILING GRID ELEVATIONS, ORIENTATIONS, AND POSITIONS. REFLECTED CEILING GRID MAY VARY FROM THAT SHOWN ON THIS DRAWING.

CONTRACTOR SHALL REMOVE AND TURN OVER ALL CEILING TILES IDENTIFIED BY THE OWNER TO BE

SALVAGED. THE REMAINDER SHALL BE DISPOSED OF BY THE CONTRACTOR.

CONTRACTOR SHALL REMOVE ALL EXISTING ACOUSTICAL CEILING PANEL (ACT) AND ASSOCIATED

GRID SYSTEM COMPLETE.

PROVIDE NEW 24" X 24" ACOUSTICAL CEILING PANEL (ACT) GRID SYSTEMS AND TILES THROUGHOUT, CEILING GRID PLACEMENT IS APPROXIMATE. FIELD VERIFY EXACT PLACEMENT.

CONTRACTOR SHALL COORDINATE EXACT QUANTITY AND LOCATION OF THE NEW CEILING TILES

AND GRID SYSTEM WITH LIGHTING AND AUXILIARY SYSTEMS DRAWINGS.

ALL EXISTING GYPSUM BOARD CEILINGS TO REMAIN.

ALL NEW BULK HEADS SHALL COMPLY WITH "TYPICAL NEW BULKHEAD DETAIL" ON DRAWING CP101.

PAINT ALL BULKHEADS AND EXISTING GYPSUM BOARD CEILINGS WHITE TO MATCH ADJACENT WALL

COLOR.

(REFLECTED CEILING DRAWINGS)

1.

2.

3.

4.

5.

6.

7.

8.

9.

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

M

AT

C H

LI

N

E A

M

AT

C H

LI

N

E B

MATC

HLIN

E A

MATC

HLIN

E C

MATCHLINE B

MATCHLINE D

MD

S S

SS

S S

S

S

S S

S

S

S

S

S

S

S

S

WA

LIBRARY

MAIN OFFICE

ROOM 1ROOM 2ROOM 3

ROOM 5

ROOM 7

ROOM 8

GIRLS ROOM

ROOM 4

ROOM 6

COURTYARD

OASIS

ROOM

ROOM 14

COURTYARD

GUIDANCE

CONFERENCE

ROOM

ROOM 18ROOM 16

ROOM

JANITOR

S

WA

WA

WA

WA

WA

WA

TEACHER'S

LOUNGE

WA

AC

AC

S S

S S

S

WA

H V

A C

S S

S S S S

AC

WA

CPD102

FL

O

O R

P

LA

N

AR

EA

A

R

EF

LE

C

TE

D

C

EI

LI

N

G

D

EM

O

LI

TI

O

N

FLOOR PLAN - AREA A - REFLECTED CEILING - DEMOLITION

SCALE: 1/8" = 1'-0"

DEMOLITION NOTES:

1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.

B

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

MATC

HLIN

E A

MATC

HLIN

E C

M

AT

C H

LI

N

E C

M

AT

C H

LI

N

E D

S

S

CAFETERIA

KITCHEN

ROOM 11

ROOM 12 ROOM 13

POD 1

POD 2

SHOP ROOM 17

ROOM 15

MENS

HANDICAP

ROOM 19B

ORCHESTRA

ROOM 19

STORAGE

R

WA

PANTRY

SHOP ROOM 15

HIGH

VOLTAGE

XFMRS

S

SS

S S

S

KITCHEN

HOOD

FLOOR PLAN - AREA C - REFLECTED CEILING - DEMOLITION

SCALE: 1/8" = 1'-0"

CPD103

FL

O

O R

P

LA

N

AR

EA

C

R

EF

LE

C

TE

D

C

EI

LI

N

G

D

EM

O

LI

TI

O

N

DEMOLITION NOTES:

1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

MATCHLINE B

MATCHLINE D

M

AT

C H

LI

N

E C

M

AT

C H

LI

N

E D

S S S S

S

S

S S

SSSSS

S

S S

S

WA

WA

RO

ROOM

AUDITORIUM

GYMNASIUM

ROOM 10 ROOM 9

BOYS

LOCKER

GIRLS

LOCKER

STAGE

GIRLS ROOM BOYS ROOM

RESOURCE

OFFICE

WAWA

8TH

GRADE

WA

GYM PANEL

S S

S S

SS

S

EF EF

MD

FLOOR PLAN - AREA D - REFLECTED CEILING - DEMOLITION

SCALE: 1/8" = 1'-0"

CPD104

FL

O

O R

P

LA

N

AR

EA

D

R

EF

LE

C

TE

D

P

LA

N

D

EM

O

LI

TI

O

N

DEMOLITION NOTES:

1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.

FL

O

O R

P

LA

N

AR

EA

A

R

EF

LE

C

TE

D

C

EI

LI

N

G

D

EM

O

LI

TI

O

N D

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

WA

WA

WA

WA

WA

M

AT

C H

LI

N

E A

M

AT

C H

LI

N

E B

MATC

HLIN

E A

MATC

HLIN

E C

S

S

S

S

S

S

S

S

S

S S

S S

S

S

S

S

S

S

ROOM 23

ROOM 21

ROOM 48

ROOM 29

ROOM 39

ROOM

ROOM 38 ROOM 47

ROOM 36 ROOM 45

ROOM 34 ROOM 43

ROOM 32 ROOM 41

ROOM 46

ROOM 44

ROOM 42

ROOM

ROOM

CLINIC

GIRLS ROOM

BOYS ROOM

STORAGE

STORAGE

ROOM 20

STORAGE

ROOM

STORAGE

FOR

RM 30 & 40

5 5 5 5

13 77

55555

1 1

1 1

1 1

6 6

S E 3

S E S E 3

S E 3

S E

S E

S E

SE

SE

WA

WA

WA WA

WA WA

WA

WA

WA

S E

SE

SE

WA

SE

SE

S E

S E

S E

SESE

SESE

3 3

SE

S E 3

S E

S E 3

S E

S E

SE

SE

S E

S E

S E S E

SE

S E

SE

SE 14

SE

SE

SE

S E S E

3 3

S E

SE

S E

ROOM 27

ROOM 26

ROOM 25

ROOM 24

SE

S E S E

S E S E

S E

S E

SESE

SE

S E

SE SE

S E

S E S E

S E

GIRLS

ROOM

BOYS

ROOM

SE SESE

SESESESE

SESE SESE

SESE SESE

S E

SE

SE SE

S E S E

S E

SE

7 S E

SE

S E

S E S E

S E S E

S

CUSTODIAN

ROOM

XFMR

ROOM

STOR

ROOM

SE

SE 3

SE 3

S E

ROOM 33

ROOM 35

ROOM 37

S S S

S

S

S

S

S

S

S

S

S

WA

S

S

6WA

S

7 SE

7 SE

ED101

FL

O

O R

P

LA

N

AR

EA

A

LI

G

H

TI

N G

D

EM

O

LI

TI

O N

FLOOR PLAN - AREA A - LIGHTING - DEMOLITION

SCALE: 1/8" = 1'-0"

DEMOLITION NOTES:

1 DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES SHOWN IN THIS SPACE. REMOVE ALL

BRANCH CIRCUITRY BETWEEN LIGHT FIXTURES. SAVE HOMERUN BRANCH CIRCUITRY INTO THIS SPACE FOR

REUSE.

REMOVE SURFACE MOUNTED LIGHT FIXTURE. SAVE BRANCH CIRCUITRY FOR REUSE.

LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY TO REMAIN. CONTRACTOR SHALL MAINTAIN

EXISTING LIGHTING CONTROL SEQUENCE IN THIS SPACE.

DISCONNECT AND REMOVE ALL CEILING MOUNTED SPEAKERS, SECURITY CAMERAS, WIRELESS ACCESS DEVICES, AND MOTION DETECTORS SHOWN ON THIS DRAWING, U.O.N., AND SAVE FOR REUSE. SAVE ALL CABLES FOR REUSE. THE CONTRACTOR SHALL LABEL EACH EQUIPMENT/DEVICE WITH REGARDS TO ROOM NUMBER AND LOCATION TO ENSURE EACH EQUIPMENT/DEVICE IS REINSTALLED IN THE NEW CEILINGS IN THE SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE REMOVED. THE CONTRACTOR SHALL PROVIDE

THE FOLLOWING FOR EACH SECURITY CAMERA:

a. LABEL AND DOCUMENT EACH EQUIPMENT LOCATION AND ORIENTATION.

b. T-GRID HANGER BRACKET AND BOX WITH SCREW SHALL BE KEPT AND REUSED AT TIME OF

REINSTALLATION.

c. CAMERAS AND ALL OTHER DEVICES SHALL BE INSTALLED IN SAME AREA AND IN THE SAME

ORIENTATION AS ORIGINAL.

d. CAMERA REINSTALLATION SHALL TAKE INTO ACCOUNT ANY NEW OBSTRUCTIONS THAT IMPACT THE

LOCATION AND/OR THE VIEWABLE AREA OF THE CAMERA SUCH AS LIGHTS AND EXIT SIGNS.

e. IF CAMERA LENS NEEDS TO BE ADJUSTED, THE CONTRACTOR SHALL WORK WITH SUFFOLK COUNTY

SCHOOL TECHNOLOGY STAFF TO REALIGN.

TEMPORARY SUPPORT ALL CEILING MOUNTED SMOKE DETECTOR DEVICES SHOWN ON THIS DRAWING FROM EXISTING ROOF STRUCTURE TO ACCOMMODATE THE REMOVAL OF EXISTING CEILING AND THE INSTALLATION OF NEW CEILING. REINSTALL ALL EXISTING CEILING MOUNTED SMOKE DETECTORS ON THE NEW CEILINGS, IN

THE SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE REMOVED.

REMOVE CEILING MOUNTED DIFFUSER. EXISTING MECHANICAL EQUIPMENT AND MATERIAL TO REMAIN. SEE " EXISTING CEILING DIFFUSER INSTALLATION DETAIL " ON DRAWING E002 FOR ADDITIONAL INFORMATION.

CEILING MOUNTED HVAC CONCENTRIC AIRFLOW UNIT TO REMAIN IN PLACE.

REMOVE CEILING MOUNTED FANS ALONG WITH ITS ASSOCIATED BRANCH CIRCUITRY BACK TO ITS SOURCE

OF CONTROL. REMOVE CONTROL SWITCH AND PROVIDE BLANK COVERPLATE ON OUTLET BOX.

REMOVE EXHAUST FAN GRILL. FAN TO REMAIN FOR REUSE.

REMOVE CEILING MOUNTED BATTERY PACKS WITH LAMP HEADS. REMOVE BRANCH CIRCUITRY BACK TO

POINT OF ORIGIN.

DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES IN CORRIDORS. SAVE ALL BRANCH

CIRCUITRY FOR REUSE.

SAVE FOR REUSE ALL LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY CONTROLLING CORRIDORS LIGHT FIXTURES. CONTRACTOR SHALL MAINTAIN EXISTING LIGHTING CONTROL SEQUENCE IN ALL

CORRIDORS.

REMOVE ALL EXIT LIGHT FIXTURES SHOWN ON THIS DRAWING. SAVE BRANCH CIRCUITRY FOR REUSE.

DISCONNECT AND REMOVE ALL PENDANT MOUNTED LIGHT FIXTURES SHOWN IN THIS SPACE. REMOVE ALL BRANCH CIRCUITRY BETWEEN LIGHT FIXTURES. SAVE HOMERUN BRANCH CIRCUITRY INTO THIS SPACE FOR

REUSE.

REMOVE LIGHT SWITCH AND SWITCH LEG CONDUCTORS. SAVE OUTLET BOX AND CONDUIT FOR REUSE.

(THIS DRAWING ONLY)

10 11 12

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

M

AT

C H

LI

N

E A

M

AT

C H

LI

N

E B

MATCHLINE B

MATCHLINE D

S S

SS

S S

S

S

S S

S

S

S

S

S

S

S

S

WA

LIBRARY

MAIN OFFICE

ROOM 1ROOM 2ROOM 3

ROOM 5

ROOM 7

ROOM 8

GIRLS ROOM

ROOM 4

ROOM 6

COURTYARD

OASIS

ROOM

ROOM 14

COURTYARD

GUIDANCE

CONFERENCE

ROOM

ROOM 18ROOM 16

ROOM

JANITOR 2

555555555

5 5 5

5 5 5 5

5 1

1212121212

1 1

1 1 1

8 8 88

S

1 1

WA

WA

WA

S E

SE

S E

S E

SESE

SE

SESE

SE

S E

3 SE

SE

SE

SE 3

SESESE

SE

SE

S E

S E

SE 3

SE

3SE3

S E

SE

SESE SE3

S E

SE

S E S E

S E S E

S E

S E

S E

SE SE

S E S E

S E S E

S E

SE

S E S E

SE

S E S E

SE

7 7

S E S E S E

7 7 7 7

SESE

SESE

SESE

S E S E

S E

WA

WA

WA

S E S E

S E

TEACHER'S

LOUNGE

SE

S E

S E

S ES E

S E S E

SE

SE

SE

S E

SE

SE

SESESE

S E

SE

WA

SESESE

S E

S E

S E 7

SE

SESESESE SESE

6 6 6

S E7

SESE

AC

AC

S S

S S

S

WA

H V

A C

5555 6

S E

SE

S S

S S S S

AC

WA 2

SE 3

SE

3 3

SE

S E

FLOOR PLAN - AREA B - LIGHTING AND AUXILIARY SYSTEMS - DEMOLITION

SCALE: 1/8" = 1'-0"

ED102

FL

O

O R

P

LA

N

AR

EA

B

LI

G

H

TI

N G

D

EM

O

LI

TI

O N

DEMOLITION NOTES:

1 DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES

SHOWN IN THIS SPACE. REMOVE ALL BRANCH CIRCUITRY BETWEEN

LIGHT FIXTURES. SAVE HOMERUN BRANCH CIRCUITRY INTO THIS

SPACE FOR REUSE.

REMOVE SURFACE/PENDANT MOUNTED LIGHT FIXTURE. SAVE

BRANCH CIRCUITRY FOR REUSE.

LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY TO REMAIN.

CONTRACTOR SHALL MAINTAIN EXISTING LIGHTING CONTROL

SEQUENCE IN THIS SPACE.

DISCONNECT AND REMOVE ALL CEILING MOUNTED SPEAKERS,

SECURITY CAMERAS, WIRELESS ACCESS DEVICES, AND MOTION

DETECTORS SHOWN ON THIS DRAWING, U.O.N., AND SAVE FOR REUSE.

SAVE ALL CABLES FOR REUSE. THE CONTRACTOR SHALL LABEL EACH

EQUIPMENT/DEVICE WITH REGARDS TO ROOM NUMBER AND LOCATION

TO ENSURE EACH EQUIPMENT IS REINSTALLED IN THE NEW CEILINGS

IN THE SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE

REMOVED. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING FOR

EACH SECURITY CAMERA:

a. LABEL AND DOCUMENT EACH EQUIPMENT LOCATION AND

ORIENTATION.

b. T-GRID HANGER BRACKET AND BOX WITH SCREW SHALL BE

KEPT AND REUSED AT TIME OF REINSTALLATION.

c. CAMERAS AND ALL OTHER DEVICES SHALL BE INSTALLED IN

SAME AREA AND IN THE SAME ORIENTATION AS ORIGINAL.

d. CAMERA REINSTALLATION SHALL TAKE INTO ACCOUNT ANY

NEW OBSTRUCTIONS THAT IMPACT THE LOCATION AND/OR

THE VIEWABLE AREA OF THE CAMERA SUCH AS LIGHTS AND

EXIT SIGNS.

e. IF CAMERA LENS NEEDS TO BE ADJUSTED, THE CONTRACTOR

SHALL WORK WITH SUFFOLK COUNTY SCHOOL TECHNOLOGY

STAFF TO REALIGN.

TEMPORARY SUPPORT ALL CEILING MOUNTED SMOKE DETECTOR

DEVICES SHOWN ON THIS DRAWING FROM EXISTING ROOF

STRUCTURE TO ACCOMMODATE THE REMOVAL OF EXISTING CEILING

AND THE INSTALLATION OF NEW CEILING. REINSTALL ALL EXISTING

CEILING MOUNTED SMOKE DETECTORS ON THE NEW CEILINGS, IN THE

SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE

REMOVED.

REMOVE CEILING MOUNTED DIFFUSER. EXISTING MECHANICAL

EQUIPMENT AND MATERIAL TO REMAIN. SEE " EXISTING CEILING

DIFFUSER INSTALLATION DETAIL " ON DRAWING E002 FOR ADDITIONAL

INFORMATION.

CEILING MOUNTED HVAC CONCENTRIC AIRFLOW UNIT TO REMAIN IN

PLACE.

REMOVE CEILING MOUNTED FANS ALONG WITH ITS ASSOCIATED

BRANCH CIRCUITRY BACK TO ITS SOURCE OF CONTROL. REMOVE

CONTROL SWITCH AND PROVIDE BLANK COVERPLATE ON OUTLET BOX.

REMOVE LIGHT SWITCH AND SWITCH LEG CONDUCTORS. SAVE

OUTLET BOX AND CONDUIT FOR REUSE.

DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES

IN CORRIDORS. SAVE ALL BRANCH CIRCUITRY FOR REUSE.

SAVE FOR REUSE ALL LIGHT SWITCH(ES) AND SWITCH LEG BRANCH

CIRCUITRY CONTROLLING CORRIDORS LIGHT FIXTURES.

CONTRACTOR SHALL MAINTAIN EXISTING LIGHTING CONTROL

SEQUENCE IN ALL CORRIDORS.

REMOVE ALL EXIT LIGHT FIXTURE SHOWN ON THIS DRAWING. SAVE

BRANCH CIRCUITRY FOR REUSE.

DISCONNECT AND REMOVE ALL PENDANT MOUNTED LIGHT FIXTURES

SHOWN IN THIS SPACE. REMOVE ALL BRANCH CIRCUITRY BETWEEN

LIGHT FIXTURES. SAVE HOMERUN BRANCH CIRCUITRY INTO THIS

SPACE FOR REUSE.

(THIS DRAWING ONLY)

4 9 10 11

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

MATC

HLIN

E A

MATC

HLIN

E C

M

AT

C H

LI

N

E C

S

S

CAFETERIA

KITCHEN

ROOM 11

ROOM 12 ROOM 13

POD 1

POD 2

SHOP ROOM 17

ROOM 15

MENS

HANDICAP

ROOM 19B

ORCHESTRA

ROOM 19

STORAGE

1 1

8 8 8

8 8

SE

SE SE SE

SE

SE

S E

SE

S E S E

S E S E

S E

SE

S E

WA

S E3

SE SE

SE SE SE SE

SE

S E

SE

SE

3 S E S E 7

SESE

SE

SE

S E8

SESESESESE

SESE

S E

PANTRY

SESESE

S E

SE

SE

SHOP ROOM 15 11

SESESESESESE

S E

S E S E

S E

SESESES SESE

3 3 3 3

SE

8 8

HIGH

VOLTAGE

XFMRS

SE

11 2 11 11

SE

11111111

S E

S

SS

S S

S

S E 3

FLOOR PLAN - AREA C - LIGHTING AND AUXILIARY SYSTEMS - DEMOLITION

SCALE: 1/8" = 1'-0"

ED103

FL

O

O R

P

LA

N

AR

EA

C

LI

G

H

TI

N G

D

EM

O

LI

TI

O N

DEMOLITION NOTES: (THIS DRAWING ONLY)

1 DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES SHOWN IN THIS

SPACE. REMOVE ALL BRANCH CIRCUITRY BETWEEN LIGHT FIXTURES. SAVE HOMERUN

BRANCH CIRCUITRY INTO THIS SPACE FOR REUSE.

REMOVE ALL SURFACE/PENDANT MOUNTED LIGHT FIXTURES. SAVE BRANCH

CIRCUITRY FOR REUSE.

LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY TO REMAIN. CONTRACTOR

SHALL MAINTAIN EXISTING LIGHTING CONTROL SEQUENCE IN THIS SPACE.

DISCONNECT AND REMOVE ALL CEILING MOUNTED SPEAKERS, SECURITY CAMERAS,

WIRELESS ACCESS DEVICES, SMOKE DETECTORS, AND MOTION DETECTORS SHOWN

ON THIS DRAWING, U.O.N., AND SAVE FOR REUSE. SAVE ALL CABLES FOR REUSE. THE

CONTRACTOR SHALL LABEL EACH EQUIPMENT/DEVICE WITH REGARDS TO ROOM

NUMBER AND LOCATION TO ENSURE EACH EQUIPMENT/DEVICE IS REINSTALLED IN THE

NEW CEILINGS IN THE SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE

REMOVED. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING FOR EACH SECURITY

CAMERA:

a. LABEL AND DOCUMENT EACH EQUIPMENT LOCATION AND ORIENTATION.

b. T-GRID HANGER BRACKET AND BOX WITH SCREW SHALL BE KEPT AND REUSED AT

TIME OF REINSTALLATION.

c. CAMERAS AND ALL OTHER DEVICES SHALL BE INSTALLED IN SAME AREA AND IN

THE SAME ORIENTATION AS ORIGINAL.

d. CAMERA REINSTALLATION SHALL TAKE INTO ACCOUNT ANY NEW OBSTRUCTIONS

THAT IMPACT THE LOCATION AND/OR THE VIEWABLE AREA OF THE CAMERA SUCH AS

LIGHTS AND EXIT SIGNS.

e. IF CAMERA LENS NEEDS TO BE ADJUSTED, THE CONTRACTOR SHALL WORK WITH

SUFFOLK COUNTY SCHOOL TECHNOLOGY STAFF TO REALIGN.

TEMPORARY SUPPORT ALL CEILING MOUNTED SMOKE DETECTOR DEVICES SHOWN ON

THIS DRAWING FROM EXISTING ROOF STRUCTURE TO ACCOMMODATE THE REMOVAL

OF EXISTING CEILING AND THE INSTALLATION OF NEW CEILING. REINSTALL ALL

EXISTING CEILING MOUNTED SMOKE DETECTORS ON THE NEW CEILINGS, IN THE SAME

OR APPROXIMATE LOCATION FROM WHICH THEY WERE REMOVED.

REMOVE CEILING MOUNTED DIFFUSER. EXISTING MECHANICAL EQUIPMENT AND

MATERIAL TO REMAIN, U.O.N SEE " EXISTING CEILING DIFFUSER INSTALLATION DETAIL "

ON DRAWING E002 FOR ADDITIONAL INFORMATION.

DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES IN CORRIDORS.

SAVE ALL BRANCH CIRCUITRY FOR REUSE.

CEILING MOUNTED HVAC CONCENTRIC AIRFLOW UNIT TO REMAIN IN PLACE.

REMOVE CEILING MOUNTED FANS ALONG WITH ITS ASSOCIATED BRANCH CIRCUITRY

BACK TO ITS SOURCE OF CONTROL. REMOVE CONTROL SWITCH AND PROVIDE BLANK

COVERPLATE ON OUTLET BOX.

SAVE FOR REUSE ALL LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY

CONTROLLING CORRIDORS LIGHT FIXTURES. CONTRACTOR SHALL MAINTAIN EXISTING

LIGHTING CONTROL SEQUENCE IN ALL CORRIDORS.

REMOVE ALL EXIT LIGHT FIXTURES SHOWN ON THIS DRAWING. SAVE BRANCH

CIRCUITRY FOR REUSE.

ALL LIGHT FIXTURES SHOWN IN THIS SPACE ARE EXISTING TO REMAIN. REMOVE AND

REPLACE ALL EXISTING INCANDESCENT LAMPS WITH LED OF EQUAL LUMENS OUTPUT.

CONTRACTOR SHALL FIELD VERIFY ALL LAMPS WATTAGE AND LUMENS.

4 6 9 10

M

AT

C H

LI

N

E D

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

MATCHLINE B

MATCHLINE D

M

AT

C H

LI

N

E C

M

AT

C H

LI

N

E D

S S S S

S

S

SSSSS S S

S

WA

WA

AUDITORIUM

GYMNASIUM

ROOM 10 ROOM 9

BOYS LOCKERGIRLS LOCKER

STAGE

GIRLS ROOM BOYS ROOM

RESOURCE

OFFICE

2 2

WAWA

SESE

S E

SE

S E

S E

SE

SE

SESE

SE

SE

S E

S E

SE

S E

S E

16 S E S E

S E

SE

SE

8TH

GRADE

SE

SESESE

SE

S E S E

S E S E

S E

S E

SE

S E

SE

SE

S E S E

S E

SE

SE

S E

SE

SE

SE

SE

S E

SE

S E

GYM PANEL

S E

S E

SE

SE

14 14

S S

S S

SS

S

EF EF

S E

SE

3 3

MD

17 17

555555

FLOOR PLAN - AREA D - LIGHTING AND AUXILIARY SYSTEMS - DEMOLITION

SCALE: 1/8" = 1'-0"

ED104

FL

O

O R

P

LA

N

AR

EA

D

LI

G

H

TI

N G

D

EM

O

LI

TI

O N

DEMOLITION NOTES: (THIS DRAWING ONLY)

1 EXISTING LIGHT FIXTURE TO REMAIN. REMOVE AND

REPLACE ALL EXISTING INCANDESCENT / FLUORESCENT

LAMP WITH LED OF EQUAL LUMENS OUTPUT.

CONTRACTOR SHALL FIELD VERIFY ALL LAMPS

WATTAGE AND LUMENS.

REMOVE SURFACE/PENDANT MOUNTED LIGHT FIXTURE.

SAVE BRANCH CIRCUITRY FOR REUSE.

LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY

TO REMAIN. CONTRACTOR SHALL MAINTAIN EXISTING

LIGHTING CONTROL SEQUENCE IN THIS SPACE.

DISCONNECT AND REMOVE ALL CEILING MOUNTED

SPEAKERS, SECURITY CAMERAS, WIRELESS ACCESS

DEVICES, AND MOTION DETECTORS SHOWN ON THIS

DRAWING, U.O.N., AND SAVE FOR REUSE. SAVE ALL

CABLES FOR REUSE. THE CONTRACTOR SHALL LABEL

EACH EQUIPMENT/DEVICE WITH REGARDS TO ROOM

NUMBER AND LOCATION TO ENSURE EACH

EQUIPMENT/DEVICE IS REINSTALLED IN THE NEW

CEILINGS IN THE SAME OR APPROXIMATE LOCATION

FROM WHICH THEY WERE REMOVED. THE CONTRACTOR

SHALL PROVIDE THE FOLLOWING FOR EACH SECURITY

CAMERA:

a. LABEL AND DOCUMENT EACH EQUIPMENT

LOCATION AND ORIENTATION.

b. T-GRID HANGER BRACKET AND BOX WITH SCREW

SHALL BE KEPT AND REUSED AT TIME OF

REINSTALLATION.

c. CAMERAS AND ALL OTHER DEVICES SHALL BE

INSTALLED IN SAME AREA AND IN THE SAME

ORIENTATION AS ORIGINAL.

d. CAMERA REINSTALLATION SHALL TAKE INTO

ACCOUNT ANY NEW OBSTRUCTIONS THAT IMPACT

THE LOCATION AND/OR THE VIEWABLE AREA OF

THE CAMERA SUCH AS LIGHTS AND EXIT SIGNS.

e. IF CAMERA LENS NEEDS TO BE ADJUSTED, THE

CONTRACTOR SHALL WORK WITH SUFFOLK

COUNTY SCHOOL TECHNOLOGY STAFF TO

REALIGN.

TEMPORARY SUPPORT ALL CEILING MOUNTED SMOKE

DETECTOR U.O.N., DEVICES SHOWN ON THIS DRAWING

FROM EXISTING ROOF STRUCTURE TO ACCOMMODATE

THE REMOVAL OF EXISTING CEILING AND THE

INSTALLATION OF NEW CEILING. REINSTALL ALL

EXISTING CEILING MOUNTED SMOKE DETECTORS ON

THE NEW CEILINGS, IN THE SAME OR APPROXIMATE

LOCATION FROM WHICH THEY WERE REMOVED.

REMOVE CEILING MOUNTED DIFFUSER. EXISTING

MECHANICAL EQUIPMENT AND MATERIAL TO REMAIN,

U.O.N SEE "EXISTING CEILING DIFFUSER INSTALLATION

DETAIL" ON DRAWING E002 FOR ADDITIONAL

INFORMATION.

DISCONNECT AND REMOVE ALL RECESSED MOUNTED

LIGHT FIXTURES IN CORRIDORS. SAVE ALL BRANCH

CIRCUITRY FOR REUSE.

CEILING MOUNTED HVAC CONCENTRIC AIRFLOW UNIT TO

REMAIN IN PLACE.

REMOVE CEILING MOUNTED FANS ALONG WITH ITS

ASSOCIATED BRANCH CIRCUITRY BACK TO ITS SOURCE

OF CONTROL. REMOVE CONTROL SWITCH AND PROVIDE

BLANK COVERPLATE ON OUTLET BOX.

SAVE FOR REUSE ALL LIGHT SWITCH(ES) AND SWITCH

LEG BRANCH CIRCUITRY CONTROLLING CORRIDORS

LIGHT FIXTURES. CONTRACTOR SHALL MAINTAIN

EXISTING LIGHTING CONTROL SEQUENCE IN ALL

CORRIDORS.

REMOVE ALL EXIT LIGHT FIXTURES SHOWN ON THIS

DRAWING. SAVE BRANCH CIRCUITRY FOR REUSE.

REMOVE ALL PENDANT MOUNTED LIGHT FIXTURES IN THE

GYMNASIUM. SAVE ALL BRANCH CIRCUITRY FOR REUSE.

EXISTING PANELS SERVING GYMNASIUM LIGHT

FIXTURES TO REMAIN.

REMOVE ALL LIGHT FIXTURES IN THE AUDITORIUM

LAY-IN TILE CEILING AND SAVE FOR REUSE. SAVE

BRANCH CIRCUITRY FOR REUSE.

EXISTING CEILING MOUNTED LIGHT FIXTURE AND

BRANCH CIRCUITRY TO REMAIN.

EXISTING LIGHT FIXTURE IN THIS SPACE TO REMAIN.

REMOVE AND REPLACE ALL EXISTING INCANDESCENT

LAMP WITH LED OF EQUAL LUMENS OUTPUT.

REMOVE LIGHT SWITCH AND SWITCH LEG CONDUCTORS.

PROVIDE BLANK COVERPLATE ON OUTLET BOX.

REMOVE EXHAUST FAN GRILL. FAN TO REMAIN FOR

REUSE.

EXISTING SMOKE DETECTOR TO REMAIN.

4 6 9 10

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

CP101

FL

O

O R

P

LA

N

AR

EA

A

R

EF

LE

C

TE

D

C

EI

LI

N

G

N

EW

W O

R K

FLOOR PLAN - AREA A - REFLECTED CEILING - NEW WORK

SCALE: 1/8" = 1'-0"

NEW WORK NOTES:

1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.

M

AT

C H

LI

N

E A

M

AT

C H

LI

N

E B

MATC

HLIN

E A

MATC

HLIN

E C

WA

WA

WA

WA

WA

ACAC

ACAC

AC

WA

OS

OS OS

WA

WA

WA

WA

WA

WA

WA

WAWA

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

OS

OS

OS

ROOM 23

ROOM 21

ROOM 48

ROOM 29

ROOM 39

ROOM 49

ROOM 38

ROOM 47

ROOM 36 ROOM 45

ROOM 34

ROOM 43

ROOM 32

ROOM 41

ROOM 46

ROOM 44

ROOM 42

ROOM 40

ROOM 30

GIRLS ROOM

BOYS ROOM

STORAGE

STORAGE

ROOM 20

STORAGE ROOM

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

ACAC

ACAC

AC

AC

AC

AC

AC

S

S

S

S

S

S

S

S

S S

S S

S

S

S

S

S

S

CLINIC

WA

OS

S E

S E

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

ROOM 27

ROOM 26

ROOM 25

ROOM 24

S E S E

S E

OS

OS

OS

S

OS

OS

OS

NEW BULKHEAD

NEW

BULKHEAD

NEW BULKHEAD NEW BULKHEAD

MTL STUD CROSS

BRACING @ 4'-0" OC

MAX

1/2" GYP BD OR

FIELD VERIFIED

3 5/8" MTL STUDS @

16" O.C. FASTEN

STRUCT ABOVE

4' 5/8"

4'- 0"

4'- 0"

SAPC - REF

FIN SCHED

TYPICAL NEW BULKHEAD DETAIL

NOT TO SCALE

THE EXISTING CEILING HEIGHT IS SHOWN.

CONTRACTOR SHALL ADJUST AS

NECESSARY WHERE VERIFIED FIELD

CONDITIONS VARY DUE TO CHANGE IN

ELEVATIONS FROM ONE SIDE TO

ANOTHER

(THIS DRAWING ONLY)

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

M

AT

C H

LI

N

E A

M

AT

C H

LI

N

E B

MATCHLINE B

MATCHLINE D

WA

OS OS

OS

OS

OS

OS

OS

OS

OS OSOS

LIBRARY

MAIN OFFICE

ROOM 1ROOM 2

ROOM 3

ROOM 5

ROOM 7

ROOM 8

GIRLS ROOM

ROOM 4

ROOM 6

COURTYARD

OASIS

ROOM

ROOM 14

COURTYARD

GUIDANCE

CONFERENCE

ROOM

ROOM 18ROOM 16

ROOM 14A

AC

AC

AC

AC

AC

AC

S S

SS

S

S

S

SS S

S

S

S

S

S

S

S

S

MD

WA

OS

OS

OSSD

OS

OS

OS

OS

S

TEACHER'S

LOUNGE

SE

OS

S S

S S

S

WA

OS

OS

NEW BULKHEADNEW BULKHEAD

NEW

BULKHEAD

NEW BULKHEAD

NEW BULKHEAD

NEW BULKHEAD

WA

FLOOR PLAN - AREA B - REFLECTED CEILING - NEW WORK

SCALE: 1/8" = 1'-0"

CP102

FL

O

O R

P

LA

N

AR

EA

B

R

EF

LE

C

TE

D

C

EI

LI

N

G

N

EW

W O

R K

NEW WORK NOTES:

1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.

(THIS DRAWING ONLY)

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020 RRMM Architects, PC

/0

4/

9:

:0

BI

M

8-

C

C

PS

N ew

M id dl e

Sc ho ol /1

-0 v2

C C

PS

N ew M

S

- A

R C

H .rv t

J

U N

E

XX

XX

X-

XX

PA M

W

H

KC

JO

H

N Y

EA

TE

S M

ID

D

LE

S

C H

O O

L

SU

FF

O

LK

P

U

BL

IC

S

C H

O O

LS

SU

FF

O

LK

, V

IR

G

IN

IA

B

EN

N

ET

TS

P

AS

TU

R E

R O

AD

KEY PLAN

NOT TO SCALE

AB

C

D

THOMPSON

Consulting Engineers

4411 COX ROAD

2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452

GLEN ALLEN, VA 23060

TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109

22 ENTERPRISE PARKWAY HAMPTON, VA 23666

MATC

HLIN

E C

M

AT

C H

LI

N

E C

M

AT

C H

LI

N

E D

WA

AC

AC

S

S

OS

S

OS OSOS

OS OS OS

OS

OS

OS

FLOOR PLAN - AREA C - REFLECTED CEILING - NEW WORK

SCALE: 1/8" = 1'-0"

CP103

FL

O

O R

P

LA

N

AR

EA

C

R

EF

LE

C

TE

D

C

EI

LI

N

G

N

EW

W O

R K

CAFETERIA

KITCHEN

ROOM 11 ROOM 12 ROOM 13

POD 1

POD 2

SHOP ROOM 17

ROOM 15

MENS

HANDICAP

ROOM 19B

ROOM 19A

STORAGE

NEW WORK NOTES: (THIS DRAWING ONLY)

1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.

D

AT

E

D R

AW

N

PR

O

JE

C

T

D

ES

IG

N

ED

C H

EC

KE

D

(804)277-8987

115 South 15 th Street, Suite 202 Richmond, Virginia 23219

M

AR

K

R

EV

IS

IO

N S

D

AT

E

BY

D

ES

C R

IP

TI

O N

0' 16' 32' 48' 1/32" = 1'-0"

0' 8' 16' 24' 1/16" = 1'-0"

4' 0' 4' 8' 16' 3/32 = 1'-0"

0' 4' 8' 12' 1/8" = 1'-0"

0' 2' 4' 6' 1/4" = 1'-0"

0' 1' 2' 4' 3/8" = 1'-0"

3' 0' 1' 2' 3' 1/2" = 1'-0"

6" 0' 1' 2' 3/4" = 1'-0"

6" 0' 6" 1' 1.5' 1" = 1'-0"

3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"

9" 0' 2" 4" 6" 3" = 1'-0"

5"3"1" 0' 1" 2" 3" 6" = 1'-0"

0' 1" 1.5" 12" = 1'-0"

D

C

B

A

E

D

C

B

A

E

SHEET

PR

O

JE

C

T

D R

AW

IN

G

1 2 3 4 5 6

1 2 3 4 5 6

Copyright © 2020…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .