John Yeates MS - Bid.pdf
PDF 9 MB Posted
- Attached to
- John Yeates Middle School Ceiling and Lighting
- Solicitation number
- 49261
- Issued by
- Suffolk City, Virginia
About this file
This document is the bid package for the John Yeates Middle School Ceiling and Lighting project solicited by Suffolk Public Schools in Suffolk, Virginia. The project involves the demolition and replacement of the ceilings and lighting fixtures throughout the various areas of the middle school building. The bid package includes detailed demolition and new work plans for each area of the school, as well as an electrical legend, abbreviations, and general notes. Bidders are required to provide pricing for the specified light fixtures, ceiling grid, and auxiliary system installations. The bid due date is July 19, 2023, and the project is expected to be awarded shortly thereafter. The contract term and any renewal options are not specified in the provided documents.
The bid package does not include any information about pricing terms, set-asides, incumbent contractors, funding sources, or other financial details. It focuses solely on the technical requirements and scope of work for the ceiling and lighting replacement project at John Yeates Middle School in Suffolk, Virginia.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 000100 - IFB 1821 JYMS.pdf | ||
| JYMS Add 3.pdf | ||
| JYMS Ceiling and Lighting - Bidding - Project Manual.pdf | ||
| JYMS Addendum No. 1.pdf | ||
| JYMS Pre-bid sign in.pdf | ||
| JYMS Addendum2.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JOHN YEATES MIDDLE SCHOOL
SUFFOLK PUBLIC SCHOOLS
RRMM ARCHITECTS, PC
ARCHITECTURE / PLANNING / INTERIORS
VICINITY MAP CONSULTANTS OWNER LOCATION MAP
THOMPSON CONSULTING ENGINEERING
MEP ENGINEERING
22 Enterprise Parkway, Suite 200
Hampton, VA 23666 P: (757) 599-4415
F: (757) 599-4113
SUFFOLK CITY PUBLIC SCHOOLS
1507 Freeney Street
Suffolk, VA 23434
P: (757) 934-6206 F: (757) 274-0679
SITE
SITE
1317 Executive Boulevard, Suite 200 Chesapeake, VA 23320
(757) 622-2828
28 Church Avenue SW Roanoke, VA 24011
(540) 344-1212
1 Research Court, Suite 450 Rockville, MD 20850
(240) 403-4101
2900 South Quincy Street, Suite 710 Arlington, VA 22206
(703) 998-0101
115 South 15th Street, Suite 202 Richmond, VA 23219
(804) 277-8987
CEILING AND LIGHTING REPLACEMENT
SHEET INDEX
Lic. No. 10748
JEFFREY A HARRIS
T
T E C
IH
C
R
A
C
T
O M M O
N W E
A L FO
H
A N I
G I
R
I V
RRMM
ARCHITECTS, PC
1317 Executive Blvd, Suite 200
D A
T E
D R
A W
N
P R
O J E
C T
D E
S
IG
N E
D
C H
E C
K E
D
Chesapeake, Virginia 23320 (757)622-2828
M A
R K
R E
V
IS
IO
N
S
D A
T E
B Y
D E
S C
R
IP
T
IO
N
0' 16' 32' 48'
1/32" = 1'-0"
0' 8' 16' 24'
1/16" = 1'-0"
4' 0' 4' 8' 16'
3/32 = 1'-0"
0' 4' 8' 12'
1/8" = 1'-0"
0' 2' 4' 6'
1/4" = 1'-0"
0' 1' 2' 4'
3/8" = 1'-0"
3' 0' 1' 2' 3'
1/2" = 1'-0"
6" 0' 1' 2'
3/4" = 1'-0"
6" 0' 6" 1' 1.5'
1" = 1'-0"
3" 9" 0' 3" 6" 1'
1 1/2" = 1'-0"
9" 0' 2" 4" 6"
3" = 1'-0"
5"3"1" 0' 1" 2" 3"
6" = 1'-0"
0' 1" 1.5"
12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
P R
O J E
C T
D R
A W
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
06-07-2023
/1
/2
:3
:1
P
M A u to d e s k D o c s /2
-1
S
P S
L a k e la n d H
S P h a s e
/2
-1 v
L a k e la n d
H S
I n te ri o r
R e n o
P h a s e
A R
C H
.r v t
T001
-0
-2
-1
J A
H
M F
W
J A
H
T
IT
L E
S H
E E
T
S U
F F
O L
K P
U B
L
IC
S C
H O
O L S
J O
H N
Y E
A T
E S
M
ID
D L
E S
C H
O O
L
B
E N
N E
T T
S P
A S
T U
R E
R O
A D
S U
F F
O L K
V
IR
G
IN
IA
Sheet Number Sheet Title
PROJECT TITLE SHEET
T001 TITLE SHEET
ELECTRICAL
E001 ELECTRICAL LEGEND, ABBREVIATIONS, AND NOTES
E002 ELECTRICAL AND MECHANICAL DETAILS
CPD101 FLOOR PLAN - AREA A - REFLECTED CEILING - DEMOLITION
CPD102 FLOOR PLAN - AREA B - REFLECTED CEILING - DEMOLITION
CPD103 FLOOR PLAN - AREA C - REFLECTED CEILING - DEMOLITION
CPD104 FLOOR PLAN - AREA D - REFLECTED CEILING - DEMOLITION
ED101 FLOOR PLAN - AREA A - LIGHTING - DEMOLITION
Sheet Number Sheet Title
ED102 FLOOR PLAN - AREA B - LIGHTING - DEMOLITION
ED103 FLOOR PLAN - AREA C - LIGHTING - DEMOLITION
ED104 FLOOR PLAN - AREA D - LIGHTING - DEMOLITION
CP101 FLOOR PLAN - AREA A - REFLECTED CEILING - NEW WORK
CP102 FLOOR PLAN - AREA B - REFLECTED CEILING - NEW WORK
CP103 FLOOR PLAN - AREA C - REFLECTED CEILING - NEW WORK
CP104 FLOOR PLAN - AREA D - REFLECTED CEILING - NEW WORK
E101 FLOOR PLAN - AREA A - LIGHTING - NEW WORK
E102 FLOOR PLAN - AREA B - LIGHTING - NEW WORK
E103 FLOOR PLAN - AREA C - LIGHTING - NEW WORK
E104 FLOOR PLAN - AREA D - LIGHTING - NEW WORK
RRMM
ARCHITECTS, PC
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
E001
EL
EC
TR
IC
AL
L
EG
EN
D , A
BB
R
EV
IA
TI
O
N S
AN
D
N O
TE
S
ELECTRICAL LEGEND:
TELECOMMUNICATION SYSTEM:
FIRE ALARM SYSTEM:
INTERCOM SYSTEM:
INTRUSION DETECTION SYSTEM:
CCTV SYSTEM:
EXISTING CEILING MOUNTED NETWORK WIRELESS
ACCESS POINT.
EXISTING CEILING MOUNTED MOTION DETECTOR.
EXISTING CEILING MOUNTED SPEAKER.
EXISTING SMOKE DETECTOR.
EXISTING INTERIOR CEILING MOUNTED CCTV CAMERA.
S
S
MD
WA
EXISTING MECHANICAL DIFFUSER
EXISTING HEATING, VENTILATION,
AIR CONDITIONING UNIT, CEILING MOUNTED.
EXISTING EXHAUST FAN.
EXISTING LITTLE FAN.
EXISTING BIGGER FAN.
MECHANICAL LEGEND
1. WHERE EXISTING INDIVIDUAL 120V HOMERUN CIRCUITS ARE SHOWN ON THE
DRAWINGS THEY MAY BE COMBINED AS FOLLOWS:
NO MORE THAN THREE (3) PHASE CONDUCTOR PLUS THREE NEUTRALS AND
ONE (1) GROUND PER CONDUIT, EXCEPT WHERE SPECIFICALLY NOTED
OTHERWISE.
NO TWO OF THE SAME PHASE CONDUCTOR PER CONDUIT.
PROVIDE 120V CIRCUIT WITH INDIVIDUAL NEUTRALS PER CIRCUIT. NEUTRALS
MAY NOT BE SHARED BETWEEN PHASES.
2. PAINT ALL EXPOSED CONDUIT AND SURFACE METAL RACEWAY TO MATCH THE
SURFACE TO WHICH ATTACHED IF THE SURFACE IS PAINTED.
3. PROTECT BRANCH CIRCUIT WIRING FROM PAINT OVERSPRAY DURING
CONSTRUCTION TO PRESERVE COLOR-CODING. CONDUCTORS PAINTED SHALL BE
COMPLETELY CLEANED OF PAINT BEFORE FINAL CONNECTIONS ARE MADE.
4. VERIFY OUTLET BOX, DEVICE AND WIRING REQUIREMENTS FOR INTERCOM STATIONS,
SPEAKERS AND FIRE ALARM DEVICES WITH THE EXISTING SYSTEM MANUFACTURER'S
AND PROVIDE ALL MATERIAL AND LABOR REQUIRED TO EXTEND THE EXISTING
SYSTEMS (FOR ADDITION/RENOVATION PROJECTS ONLY).
5. COORDINATE WIRING DEVICE OUTLET LOCATIONS WITH ARCHITECTURAL PLANS,
ELECTRICAL PLANS, ENLARGED FLOOR PLANS, EQUIPMENT AND FURNITURE
LAYOUTS, SECTIONS, ELEVATIONS, DETAILS AND JOB SITE DIFFERENCES PRIOR TO
ROUGHING-IN CONDUITS. MAKE REQUIRED ADJUSTMENTS WITH ARCHITECTS AND
ENGINEERS APPROVAL).
6. INSTALL DEVICES SHOWN ON DRAWINGS IN ACCORDANCE WITH MOUNTING HEIGHTS
SHOWN IN THE ELECTRICAL LEGEND AND/OR THE PROJECT SPECIFICATIONS. ALL
MOUNTING HEIGHT DIMENSIONS ARE TO THE BOTTOM OF THE OUTLET BOX, UNLESS
OTHERWISE NOTED.
7. WHERE THE TERM "BRANCH CIRCUITRY" IS USED ON THESE DRAWINGS, IT IS TO BE
CONSTRUED TO MEAN CONDUIT AND CONDUCTORS.
8. TYPE “MC” CABLE IS NOT ALLOWED TO BE INSTALLED ON THIS PROJECT.
9. THE CONTRACTOR SHALL PROVIDE TOTAL NUMBER OF ALL LIGHT FIXTURES THAT IS
TO BE REMOVED AND TURN OVER TO OWNER, UNLESS OTHER WISED INSTRUCTED
BY OWNER.
12. WHERE THE EXISTING CEILINGS ARE BEING REMOVED UNDER DEMOLITION AND
REPLACED WITH NEW CEILING, CONTRACTOR SHALL MAKE THEMSELVES AWARE OF
ALL EXISTING CEILING ELEVATION HEIGHTS AND MAINTAIN THIS ELEVATION HEIGHT
FOR THE NEW CEILING.
13. PROVIDE A TYPED CIRCUIT INDEX CARD FOR EACH PANELBOARD UPON COMPLETION
OF INSTALLATION WORK. INDICATE LOAD SERVED AND ROOM NUMBER(S). USE
FINAL ROOM NUMBERS OBTAINED FROM THE ARCHITECT OR OWNER, NOT
CONSTRUCTION ROOM NUMBERS AS SHOWN ON THE DRAWINGS.
14. WHERE THE EXISTING CEILINGS ARE BEING REMOVED UNDER DEMOLITION AND
REPLACED WITH NEW CEILING, CONTRACTOR SHALL MAKE THEMSELVES AWARE OF
ALL EXISTING CEILING ELEVATION HEIGHTS AND MAINTAIN THIS ELEVATION HEIGHT
FOR THE NEW CEILING.
15. RECESSED LIGHT FIXTURES SHALL BE SUPPORTED WITH INDIVIDUAL ANNEALED,
LIGHT ZINC-COATED FINISH, 12-GAUGE WIRE FROM ALL FOUR CORNERS TIED TO
BUILDING STRUCTURAL MEMBERS. SECURE SAFETY WIRES TO BRIDGING IS NOT
ACCEPTABLE. THE SUPPORTING WIRES SHALL BE DISTINGUISHABLE BY COLOR OR
TAGGING. PROVIDE ROD HANGERS CAPABLE OF SUPPORTING TWICE THE WEIGHT
OF THE LIGHT FIXTURE SUPPORTED BY THE ROD HANGER FOR ALL SURFACE
MOUNTED LIGHT FIXTURES. ROD HANGERS SHALL BE A MINIMUM 1/4” DIAMETER.
GENERAL NOTES:
1. PERFORM ALL REQUIRED DEMOLITION TO COMPLY WITH THE SCOPE AND INTENT OF THE PROJECT. RETAIN MUCH OF THE
WIRING ASSOCIATED WITH THE REQUIRED DEMOLITION FOR REUSE.
2. VERIFY ALL CIRCUITS SAVED DURING DEMOLITION FOR REUSE AS TO WIRE SIZE AND POINT OF ORIGIN.
3. EXERCISE CARE IN REMOVING MATERIAL AND EQUIPMENT DURING DEMOLITION. REPAIR ALL DAMAGE TO EXISTING SURFACES OR EXISTING EQUIPMENT TO REMAIN TO THE SATISFACTION OF THE ARCHITECT AND OWNER AT NO ADDITIONAL
COST TO THE OWNER.
4. PROVIDE THE OWNER WITH FIRST RIGHT OF REFUSAL FOR ALL ELECTRICAL EQUIPMENT BEING REMOVED AS A PART OF THIS CONTRACT AND NOT SCHEDULED FOR REINSTALLATION. ALL ELECTRICAL EQUIPMENT NOT TURNED OVER TO THE OWNER SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE REMOVED FROM THE SITE.
5. FLUORESCENT BALLASTS IN EXISTING LIGHT FIXTURES SCHEDULED TO BE REMOVED MAY CONTAIN PCB'S. REMOVE THE BALLASTS FROM THE LIGHT FIXTURES, PROPERLY CONTAIN AND DISPOSE OF SAME IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS GOVERNING SAME.
6. FLUORESCENT LAMPS IN EXISTING LIGHT FIXTURES SCHEDULED TO BE REMOVED MAY CONTAIN MERCURY. REMOVE THE LAMPS FROM THE LIGHT FIXTURES, PROPERLY CONTAIN AND DISPOSE OF SAME IN ACCORDANCE WITH ALL FEDERAL, STATE
AND LOCAL REGULATIONS GOVERNING SAME.
7. BEFORE BEGINNING ANY WORK, FIELD VERIFY THE WORKING CONDITION OF ALL AUXILIARY SYSTEM DEVICES SCHEDULED FOR REMOVAL AND REINSTALLATION. NOTIFY THE OWNER OF ALL DEFECTIVE EQUIPMENT. AFTER THE REINSTALLATION OF ALL EQUIPMENT, RE-VERIFY THE WORKING CONDITION. REPLACE ALL EQUIPMENT FOUND DEFECTIVE AFTER REINSTALLATION, WHICH WERE WORKING PRIOR TO REMOVAL WITH EQUIPMENT TO MATCH EXISTING AT NO ADDITIONAL
COST TO THE OWNER.
8. DURING THE REMOVAL OF EXISTING CEILINGS, SUPPORT ALL EXISTING AUXILIARY SYSTEMS CABLES (DATA, INTERCOM, TELEPHONE, TELEVISION, CCTV, ETC.) FROM STRUCTURE ABOVE EXISTING CEILING. ADJUST ROUTING OF THESE CABLES TO ACCOMMODATE THE INSTALLATION OF EXISTING HVAC SYSTEM EQUIPMENT. RE-VERIFY THE WORKING CONDITION OF THESE CABLES AND REPLACE ALL CABLES FOUND DEFECTIVE AFTER REINSTALLATION, WHICH WERE WORKING PRIOR TO REMOVAL
WITH CABLES TO MATCH EXISTING AT NO ADDITIONAL COST TO THE OWNER.
9. IN AREAS WHERE NO OTHER TRADES ARE INVOLVED, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL OF EXISTING CEILING TILES AS REQUIRED TO INSTALL NEW BRANCH CIRCUITRY. CONTRACTOR SHALL INSTALL NEW CEILING TILES AFTER COMPLETION OF WORK. REPLACE ANY CEILING TILES DAMAGED DURING THIS PROJECT WITH NEW TILES TO THE
SATISFACTION OF THE ARCHITECT AND OWNER.
10. PROVIDE ALL ELECTRICAL DEMOLITION WORK NECESSARY TO INSTALL NEW WORK. REROUTE AND RECONNECT ALL CIRCUIT
THAT IS REQUIRED TO REMAIN IN USE BUT INTERFERES WITH NEW CONSTRUCTION.
11. CONDUITS MAY BE ABANDONED IN WALLS AND BELOW FIRST FLOOR SLABS ONLY. REMOVE ALL WIRING FROM ABANDONED CONDUITS. DISCONNECT CONDUCTORS FROM ALL POWER SOURCES AND PROVIDE BLANK COVERPLATES ON ALL
ABANDONED OUTLET BOXES.
12. WHERE THE TERM "BRANCH CIRCUITRY" IS USED ON THESE DRAWINGS, IT IS TO BE CONSTRUED TO MEAN CONDUIT AND
CONDUCTORS.
13. PROVIDE NEW TYPED PANEL INDEX CARDS IN EXISTING PANELBOARDS WHERE CIRCUITS HAVE BEEN MODIFIED BY THIS PROJECT. PROVIDE COPIES OF MODIFIED PANEL INDEX CARDS ON AS BUILT DRAWINGS AND INCLUDED IN OPERATION AND MAINTENANCE MANUALS. PROVIDE CIRCUIT BREAKER FILLER PLATES FOR ALL CIRCUIT BREAKERS REMOVED FROM EXISTING
PANELBOARDS DURING DEMOLITION WORK.
14. EXISTING CONDITIONS ILLUSTRATED HAVE BEEN DETERMINED FROM ORIGINAL CONSTRUCTION DOCUMENTS AND LIMITED NON-INVASIVE FIELD INVESTIGATION. CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR TO COMMENCEMENT OF
WORK, COORDINATE AND MAKE ADJUSTMENTS AS NECESSARY.
GENERAL DEMOLITION NOTES
HL
EXISTING 2 'X 4' LIGHT FIXTURE
EXISTING 1' X 1' LIGHT FIXTURE.
EXISTING 1' X 4' LIGHT FIXTURE.
EXISTING 6" DOWNLIGHT.
EXISTING EMERGENCY LIGHT FIXTURE WITH SELF-CONTAINED BATTERY PACK.
NEW 2' X 4' LED LIGHT FIXTURE . NUMBER SUBSCRIPT INDICATES LIGHT
FIXTURE TYPE.
NEW 2' X 4' LED LIGHT FIXTURE WITH SELF CONTAINED EMERGENCY BATTERY
PACK. NUMBER SUBSCRIPT INDICATES LIGHT FIXTURE TYPE. SUBSCRIPT "NL"
WHEN USED INDICATE A NIGH LIGHT (ALWAYS ON) LIGHT FIXTURE.
NEW 2' X 2' LED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES LIGHT
FIXTURE TYPE.
NEW 2' X 2' LED LIGHT FIXTURE WITH SELF CONTAINED EMERGENCY BATTERY
PACK. NUMBER SUBSCRIPT INDICATES LIGHT FIXTURE TYPE. SUBSCRIPT "NL"
WHEN USED INDICATE A NIGH LIGHT (ALWAYS ON) LIGHT FIXTURE.
NEW 1' X 4' LED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES LIGHT
FIXTURE TYPE.
NEW 1' X 4' LED LIGHT FIXTURE WITH SELF CONTAINED EMERGENCY BATTERY
PACK. NUMBER SUBSCRIPT INDICATES LIGHT FIXTURE TYPE.
NEW CEILING MOUNTED EXIT LIGHT WITH DIRECTIONAL ARROWS AS
INDICATED. SHADED AREA INDICATES FACE-LIT. NUMBER SUBSCRIPT
INDICATES LIGHT FIXTURE TYPE.
NEW SURFACE MOUNTED LIGHT FIXTURE WITH SELF-CONTAINED BATTERY
PACK, CONNECT AHEAD OF ANY LOCAL SWITCHING. NUMBER SUBSCRIPT
INDICATES LIGHT FIXTURE TYPE.
NEW SURFACE MOUNTED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES
LIGHT FIXTURE TYPE.
NEW HIGH BAY LED LIGHT FIXTURE. NUMBER SUBSCRIPT INDICATES LIGHT
FIXTURE TYPE.
NEW HIGH BAY LED LIGHT FIXTURE WITH SELF CONTAINED EMERGENCY
BATTERY PACK.
NEW SINGLE POLE SWITCH, 20A, 120/277V, AC. INSTALL +46" A.F.F., U.O.N.
SUBSCRIPT "W", WHEN USED, INDICATES DEVICE IN WIREMOLD SURFACE
NON-METALLIC OUTLET BOX.
EXISTING SINGLE POLE SWITCH, 20A, 120/277V, AC.
EXISTING THREE-WAY SWITCH, 20A, 120/277V, AC.
NEW SINGLE POLE SWITCH WITH OCCUPANCY SENSOR; SENSOR SWITCH
CATALOG # WSD-PDT. INSTALL IN EXISTING OUTLET BOX SAVED DURING
DEMOLITION.
NEW SINGLE POLE DIMMER SWITCH WITH OCCUPANCY SENSOR; SENSOR
SWITCH CATALOG # WSD-D. INSTALL IN EXISTING OUTLET BOX SAVED DURING
DEMOLITION.
NEW LOW VOLTAGE HIGH BAY OCCUPANCY SENSOR; SENSOR SWITCH
CATALOG # CM-6, OR APPROVED EQUAL. INSTALL ON CEILING WHERE
INDICATED ON PLANS. SEE "LOW VOLTAGE OCCUPANCY SENSOR DIAGRAM"
ON DRAWING E-002.
NEW CEILING MOUNTED LINE VOLTAGE OCCUPANCY SENSOR - PROVIDE
SENSOR SWITCH CATALOG # CMR-PDT-10 OR APPROVED EQUAL.
NEW 2 POLE OCCUPANCY SENSOR POWER PACK; SENSOR SWITCH CATALOG #
2-PP-20 SERIES, OR APPROVED EQUAL. INSTALL IN JUNCTION BOX ABOVE
CEILING, U.O.N.
DEMOLITION NOTE INDICATOR.
NEW WORK NOTE INDICATOR.
SW
SOSD
OS
OS
PP
ARCHITECTURAL LEGEND
BULKHEAD
CEILING
ELEVATION
BLKHD
CLG
ELEV
ABBREVIATIONS
AC ALTERNATING CURRENT
ACP ACOUSTICAL CEILING PANEL
ADA AMERICANS WITH DISABILITIES ACT
A.F.F. ABOVE FINISHED FLOOR
A.F.G. ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING CAPACITY
ATS AUTOMATIC TRANSFER SWITCH
C CONDUIT
C.B. CIRCUIT BREAKER
CIRC/CKT CIRCUIT
E EXISTING
EF EXHAUST FAN
EM EMERGENCY
LED LIGHT EMITTING DIODE
NEMA NATIONAL ELECTRICAL MANUFACTURE ASSOCIATION
N.E.C. NATIONAL ELECTRICAL CODE
NO. NUMBER
N.T.S. NOT TO SCALE
PNL PANEL
TYP TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
V VOLT
DAY-BRITE CFI
TGS CONTOUR TROFFER UNV
LIGHT FIXTURE SCHEDULE
TYPE MANUFACTURER'S CATALOG No. VOLT MOUNTING REMARKS
1 RECESSED
DAY-BRITE CFI
LIGHT FIXTURE SCHEDULE NOTES
1. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS. SHADING INDICATES NUMBER OF FACES LIT.
2. HOUSING COLOR TO BE SELECTED BY ARCHITECT.
3. PROVIDE WITH EMERGENCY BATTERY BACKUP OPTION.
4. PROVIDE PENDANT LENGTH AS REQUIRED TO INSTALL THE LIGHT FIXTURE AT THE SAME HEIGHT AS ORIGINAL TO THE BOTTOM OF FIXTURE. PROVIDE UNISTRUT CHANNEL TO SPAN UNDERSIDE OF TOP CHORD OF JOIST
TO SUSPEND LIGHT FIXTURE. PROVIDE LIGHT FIXTURE WITH A WIRE GUARD.
LEDALITE-TRUGROVE SURFACE
RECESSED
RECESSED
LAMPS
NOT USED
LEDALITE-TRUGROVE5 SURFACE
NOT USED
TGS THINTEK G2 RECESSED
DAY-BRITE CFI
TGS THINTEK G29 RECESSED
PEERLESS
MERCURY LIGHTING SURFACE
PENDANT
SURFACE
13 MERCURY LIGHTING
DAY-BRITE CFI PENDANT
SURFACE
LED
UNV
UNV
UNV
UNV
UNV
UNV
UNV
UNV
UNV
UNV
UNV
CT-24-WS35-C3500K-U
2SBP3550L8CS-4-UNV-DIM
2SBP3550L8CS-4-UNV-DIM-GTD
29-1-1-L-935-30-QN-08-D-E-1-N-G-SF
29-1-1-L-935-30-QN-08-D-E-1-N-SF
88-24-40-35-T-F-80-RM
88-24-40-35-T-F-80-RM-GTD
AMH-WA-4-40-35K-WM
RBX-20L-835-UNV-WT-ARR165-GTD-WGA22
LW45-4-4500-35K-HTA-1%-UNI
LW45-4-4500-35K-HTA-1%-UNI-GTD-WGA22
RBX-20L-835-UNV-WT-ARR165-WGA22
NOT USED
TGS CONTOUR TROFFER UNV15 RECESSED
NOT USED
TGS THINTEK G2 RECESSED
PEERLESS-PEERLUX
TGS THINTEK G219 RECESSED
PEERLESS-PEERLUX SURFACE
SURFACE
UNV
UNV
UNV
UNV
CT-24-WS35-C3500K-U-GTD
88-22-40-35-T-F-RM-GTD
AHM-WA-4-30-35K-WM
88-22-40-35-T-F-RM
AHM-WA-4-30-35K-WM-GTD
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
LED
CHLORIDE SURFACEUNVVERWEM LED
LUMENS WATTAGE
4400 48
4570 38.3
4570 38.3
3192 32.9
3192 32.9
4486 40.4
4486 40.4
3028 22.8
20366 157.9
4440 48
4440 48
20366 157.9
4400 48
4400 40
4400 40
3080 22.8
3080 22.8
270 3
SEE NOTES 2,3
SEE NOTE 1
SEE NOTE 2
DAY-BRITE CFI SURFACEUNVV2-W-A-70L-835-8-UNV-TBK LED6985 65.3
DAY-BRITE CFI SURFACEUNVV2-W-A-70L-835-8-UNV-TBK-GTD LED6985 65.3
SE
SOS
S3
SEE NOTE 3
SEE NOTE 3
SEE NOTES 3,4
SEE NOTES 3,4
SEE NOTE 3
SEE NOTE 3
SEE NOTE 3
SEE NOTE 3
NL
NL
-1
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
E002
EL
EC
TR
IC
AL
A
N D
M
EC
H
AN
IC
AL
D
ET
AI
LS
OS OS
TYPICAL LINE VOLTAGE OCCUPANCY SENSOR WIRING DIAGRAM
LIGHT SWITCH(ES)
RED
BLUE
BLACK
NOT TO SCALE
NOTES:
LED DRIVER
PROVIDE LINE VOLTAGE OCCUPANCY SENSOR. INSTALL ON CEILING WHERE INDICATED ON PLANS.
BRN
BLACK
RED
BRN
BLACK
RED
LIGHT FIXTURE WITH LED DRIVER.
OS
PP
GYM LOW VOLTAGE OCCUPANCY SENSOR
WIRING DIAGRAM
RED
BLUE
BLACK
PHASE
NEUTRAL
GROUND
Ø
Ø
NEUTRAL
Ø
NOT TO SCALE
NOTES:
PROVIDE 2 POLE POWER PACK; SENSOR SWITCH CATALOG NUMBER 2PP-20 SERIES, OR EQUAL.
PROVIDE LOW VOLTAGE HIGH BAY OCCUPANCY SENSOR; SENSOR SWITCH CATALOG NUMBER CM-6 OR
EQUAL. INSTALL WHERE INDICATED ON PLANS.
BRN
BLACK
RED
HL HLOS
LED DRIVER LED DRIVER
HANGER WIRE TO STRUCTURE
RECTANGULAR TO ROUND
EXPANDED SIDE TAKE-OFF WITH
DAMPER IN BRANCH EXTERNAL
INSULATION ON SHEET METAL
STRAIGHT DUCT OR PROVIDE
EQUALIZING GRID AT DIFFUSER
DIA.
DUCT HANGER, SIZED PER DUCT
PREINSULATED FLEXIBLE DUCT
FLEXIBLE DUCT SECURED WITH
MECHANICAL BAND CLAMPS,
USE FOIL BACKED TAPE TO
TRANSITION TO FLEXIBLE DUCT
INSULATION
(TYPICAL ALL FLEXIBLE DUCTS)
INSULATION OVERLAPPING
DIFFUSER COLLAR
FINISHED CEILING SUPPORT
SUPPLY AIR DIFFUSER FACE OR
OTHER
CEILING DIFFUSER INSTALLATION DETAIL
NOT TO SCALE
NOTES:
THE RE-INSTALLATION OF THE NEW DIFFUSERS SHALL BE PLACED IN KIND IN
LOCATION OF THOSE EXISTING. WHERE DIFFUSERS ARE LOCATED IN ANOTHER
SPACE, THE MECHANICAL CONTRACTOR SHALL EXTEND THE FLEXIBLE CONNECTION
TO NEW LOCATION.
1 1
2 2
2 2
FOOTCANDLE SCHEDULE
ROOM DESCRIPTION MINIMUM MAINTAINED
FOOTCANDLES
CLASSROOM 50-60
CORRIDOR 20-30
TOILET
CAFETERIA
LIBRARY 20-100
OFFICE 30-50
20-30
50-60
AUDITORIUM 60-70
KITCHEN 50-100
PHASE
NEUTRAL
GROUND
EXISTING GYM PANEL
EMERGENCY BATTERY BACKUP
11 14
EMERGENCY BATTERY
BACKUP, TYPICAL
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
CPD101
FL
O
O R
P
LA
N
AR
EA
A
R
EF
LE
C
TE
D
C
EI
LI
N
G
D
EM
O
LI
TI
O
N
FLOOR PLAN - AREA A - REFLECTED CEILING - DEMOLITION
SCALE: 1/8" = 1'-0"
WA
WA
WA
WA
WA
M
AT
C H
LI
N
E A
M
AT
C H
LI
N
E B
MATC
HLIN
E A
MATC
HLIN
E C
S
S
S
S
S
S
S
S
S
S S
S S
S
S
S
S
S
S
E
ROOM 23
ROOM 21
ROOM 48
ROOM 29
ROOM 39
ROOM
ROOM 38 ROOM 47
ROOM 36 ROOM 45
ROOM 34 ROOM 43
ROOM 32 ROOM 41
ROOM 46
ROOM 44
ROOM 42
ROOM
ROOM
CLINIC
GIRLS ROOM
BOYS ROOM
STORAGE
STORAGE
ROOM 20
STORAGE
ROOM
STORAGE
FOR
RM 30 & 40
WA
WA
WA WA
WA WA
WA
WA
WAWA
ROOM 27
ROOM 26
ROOM 25
ROOM 24
GIRLS
ROOM
BOYS
ROOM
S
CUSTODIAN
ROOM
XFMR
ROOM
STOR
ROOM
ROOM 33
ROOM 35
ROOM 37
S S S S
S
S
S
S
S
S
S
S
S
WA
S
S
WA
S
2 'X 4' LIGHT FIXTURE
2 'X 4' LIGHT FIXTURE [WITH SELF CONTAINED EMERGENCY
BATTERY PACK
2' X 2' LIGHT FIXTURE
2' X 2' LIGHT FIXTURE [WITH SELF CONTAINED EMERGENCY
BATTERY PACK
1' X 1' LIGHT FIXTURE
1' X 4' LIGHT FIXTURE
1' X 4' LIGHT FIXTURE [WITH SELF CONTAINED EMERGENCY
BATTERY PACK
RECESSED DOWNLIGHT
RECESSED DOWNLIGHT WITH SELF CONTAINED EMERGENCY
BATTERY PACK
EMERGENCY LIGHT FIXTURE WITH SELF-CONTAINED BATTERY
PACK
CEILING MOUNTED EXIT LIGHT
MECHANICAL DIFFUSER
HEATING, VENTILATION, AIR CONDITIONING UNIT, CEILING
MOUNTED
EXHAUST FAN
CEILING MOUNTED LITTLE FAN
CEILING MOUNTED BIGGER FAN
INTERIOR CEILING MOUNTED CCTV CAMERA
SMOKE DETECTOR
CEILING MOUNTED SPEAKER
CEILING MOUNTED MOTION DETECTOR
CEILING MOUNTED WIRELESS ACCESS DATA OUTLET
NEW BULKHEAD, SEE DRAWINGS FOR FURTHER INFORMATION
EXISTING CORRIDOR GATE
EXISTING GYPSUM BOARD CEILING
NEW CEILING GRID 24" X 24"
EXISTING CEILING GRID 48" X 24"
EXISTING SPACES WITH NO CEILING, STRUCTURE IS EXPOSED.
REFLECTED CEILING PLAN LEGEND:
EF
S
S
MD
WA
GENERAL DEMOLITION AND NEW WORK NOTES:
THE CONTRACTOR SHALL FIELD VERIFY ALL REFLECTED CEILING GRID ELEVATIONS, ORIENTATIONS, AND POSITIONS. REFLECTED CEILING GRID MAY VARY FROM THAT SHOWN ON THIS DRAWING.
CONTRACTOR SHALL REMOVE AND TURN OVER ALL CEILING TILES IDENTIFIED BY THE OWNER TO BE
SALVAGED. THE REMAINDER SHALL BE DISPOSED OF BY THE CONTRACTOR.
CONTRACTOR SHALL REMOVE ALL EXISTING ACOUSTICAL CEILING PANEL (ACT) AND ASSOCIATED
GRID SYSTEM COMPLETE.
PROVIDE NEW 24" X 24" ACOUSTICAL CEILING PANEL (ACT) GRID SYSTEMS AND TILES THROUGHOUT, CEILING GRID PLACEMENT IS APPROXIMATE. FIELD VERIFY EXACT PLACEMENT.
CONTRACTOR SHALL COORDINATE EXACT QUANTITY AND LOCATION OF THE NEW CEILING TILES
AND GRID SYSTEM WITH LIGHTING AND AUXILIARY SYSTEMS DRAWINGS.
ALL EXISTING GYPSUM BOARD CEILINGS TO REMAIN.
ALL NEW BULK HEADS SHALL COMPLY WITH "TYPICAL NEW BULKHEAD DETAIL" ON DRAWING CP101.
PAINT ALL BULKHEADS AND EXISTING GYPSUM BOARD CEILINGS WHITE TO MATCH ADJACENT WALL
COLOR.
(REFLECTED CEILING DRAWINGS)
1.
2.
3.
4.
5.
6.
7.
8.
9.
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
M
AT
C H
LI
N
E A
M
AT
C H
LI
N
E B
MATC
HLIN
E A
MATC
HLIN
E C
MATCHLINE B
MATCHLINE D
MD
S S
SS
S S
S
S
S S
S
S
S
S
S
S
S
S
WA
LIBRARY
MAIN OFFICE
ROOM 1ROOM 2ROOM 3
ROOM 5
ROOM 7
ROOM 8
GIRLS ROOM
ROOM 4
ROOM 6
COURTYARD
OASIS
ROOM
ROOM 14
COURTYARD
GUIDANCE
CONFERENCE
ROOM
ROOM 18ROOM 16
ROOM
JANITOR
S
WA
WA
WA
WA
WA
WA
TEACHER'S
LOUNGE
WA
AC
AC
S S
S S
S
WA
H V
A C
S S
S S S S
AC
WA
CPD102
FL
O
O R
P
LA
N
AR
EA
A
R
EF
LE
C
TE
D
C
EI
LI
N
G
D
EM
O
LI
TI
O
N
FLOOR PLAN - AREA A - REFLECTED CEILING - DEMOLITION
SCALE: 1/8" = 1'-0"
DEMOLITION NOTES:
1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.
B
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
MATC
HLIN
E A
MATC
HLIN
E C
M
AT
C H
LI
N
E C
M
AT
C H
LI
N
E D
S
S
CAFETERIA
KITCHEN
ROOM 11
ROOM 12 ROOM 13
POD 1
POD 2
SHOP ROOM 17
ROOM 15
MENS
HANDICAP
ROOM 19B
ORCHESTRA
ROOM 19
STORAGE
R
WA
PANTRY
SHOP ROOM 15
HIGH
VOLTAGE
XFMRS
S
SS
S S
S
KITCHEN
HOOD
FLOOR PLAN - AREA C - REFLECTED CEILING - DEMOLITION
SCALE: 1/8" = 1'-0"
CPD103
FL
O
O R
P
LA
N
AR
EA
C
R
EF
LE
C
TE
D
C
EI
LI
N
G
D
EM
O
LI
TI
O
N
DEMOLITION NOTES:
1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
MATCHLINE B
MATCHLINE D
M
AT
C H
LI
N
E C
M
AT
C H
LI
N
E D
S S S S
S
S
S S
SSSSS
S
S S
S
WA
WA
RO
ROOM
AUDITORIUM
GYMNASIUM
ROOM 10 ROOM 9
BOYS
LOCKER
GIRLS
LOCKER
STAGE
GIRLS ROOM BOYS ROOM
RESOURCE
OFFICE
WAWA
8TH
GRADE
WA
GYM PANEL
S S
S S
SS
S
EF EF
MD
FLOOR PLAN - AREA D - REFLECTED CEILING - DEMOLITION
SCALE: 1/8" = 1'-0"
CPD104
FL
O
O R
P
LA
N
AR
EA
D
R
EF
LE
C
TE
D
P
LA
N
D
EM
O
LI
TI
O
N
DEMOLITION NOTES:
1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.
FL
O
O R
P
LA
N
AR
EA
A
R
EF
LE
C
TE
D
C
EI
LI
N
G
D
EM
O
LI
TI
O
N D
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
WA
WA
WA
WA
WA
M
AT
C H
LI
N
E A
M
AT
C H
LI
N
E B
MATC
HLIN
E A
MATC
HLIN
E C
S
S
S
S
S
S
S
S
S
S S
S S
S
S
S
S
S
S
ROOM 23
ROOM 21
ROOM 48
ROOM 29
ROOM 39
ROOM
ROOM 38 ROOM 47
ROOM 36 ROOM 45
ROOM 34 ROOM 43
ROOM 32 ROOM 41
ROOM 46
ROOM 44
ROOM 42
ROOM
ROOM
CLINIC
GIRLS ROOM
BOYS ROOM
STORAGE
STORAGE
ROOM 20
STORAGE
ROOM
STORAGE
FOR
RM 30 & 40
5 5 5 5
13 77
55555
1 1
1 1
1 1
6 6
S E 3
S E S E 3
S E 3
S E
S E
S E
SE
SE
WA
WA
WA WA
WA WA
WA
WA
WA
S E
SE
SE
WA
SE
SE
S E
S E
S E
SESE
SESE
3 3
SE
S E 3
S E
S E 3
S E
S E
SE
SE
S E
S E
S E S E
SE
S E
SE
SE 14
SE
SE
SE
S E S E
3 3
S E
SE
S E
ROOM 27
ROOM 26
ROOM 25
ROOM 24
SE
S E S E
S E S E
S E
S E
SESE
SE
S E
SE SE
S E
S E S E
S E
GIRLS
ROOM
BOYS
ROOM
SE SESE
SESESESE
SESE SESE
SESE SESE
S E
SE
SE SE
S E S E
S E
SE
7 S E
SE
S E
S E S E
S E S E
S
CUSTODIAN
ROOM
XFMR
ROOM
STOR
ROOM
SE
SE 3
SE 3
S E
ROOM 33
ROOM 35
ROOM 37
S S S
S
S
S
S
S
S
S
S
S
WA
S
S
6WA
S
7 SE
7 SE
ED101
FL
O
O R
P
LA
N
AR
EA
A
LI
G
H
TI
N G
D
EM
O
LI
TI
O N
FLOOR PLAN - AREA A - LIGHTING - DEMOLITION
SCALE: 1/8" = 1'-0"
DEMOLITION NOTES:
1 DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES SHOWN IN THIS SPACE. REMOVE ALL
BRANCH CIRCUITRY BETWEEN LIGHT FIXTURES. SAVE HOMERUN BRANCH CIRCUITRY INTO THIS SPACE FOR
REUSE.
REMOVE SURFACE MOUNTED LIGHT FIXTURE. SAVE BRANCH CIRCUITRY FOR REUSE.
LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY TO REMAIN. CONTRACTOR SHALL MAINTAIN
EXISTING LIGHTING CONTROL SEQUENCE IN THIS SPACE.
DISCONNECT AND REMOVE ALL CEILING MOUNTED SPEAKERS, SECURITY CAMERAS, WIRELESS ACCESS DEVICES, AND MOTION DETECTORS SHOWN ON THIS DRAWING, U.O.N., AND SAVE FOR REUSE. SAVE ALL CABLES FOR REUSE. THE CONTRACTOR SHALL LABEL EACH EQUIPMENT/DEVICE WITH REGARDS TO ROOM NUMBER AND LOCATION TO ENSURE EACH EQUIPMENT/DEVICE IS REINSTALLED IN THE NEW CEILINGS IN THE SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE REMOVED. THE CONTRACTOR SHALL PROVIDE
THE FOLLOWING FOR EACH SECURITY CAMERA:
a. LABEL AND DOCUMENT EACH EQUIPMENT LOCATION AND ORIENTATION.
b. T-GRID HANGER BRACKET AND BOX WITH SCREW SHALL BE KEPT AND REUSED AT TIME OF
REINSTALLATION.
c. CAMERAS AND ALL OTHER DEVICES SHALL BE INSTALLED IN SAME AREA AND IN THE SAME
ORIENTATION AS ORIGINAL.
d. CAMERA REINSTALLATION SHALL TAKE INTO ACCOUNT ANY NEW OBSTRUCTIONS THAT IMPACT THE
LOCATION AND/OR THE VIEWABLE AREA OF THE CAMERA SUCH AS LIGHTS AND EXIT SIGNS.
e. IF CAMERA LENS NEEDS TO BE ADJUSTED, THE CONTRACTOR SHALL WORK WITH SUFFOLK COUNTY
SCHOOL TECHNOLOGY STAFF TO REALIGN.
TEMPORARY SUPPORT ALL CEILING MOUNTED SMOKE DETECTOR DEVICES SHOWN ON THIS DRAWING FROM EXISTING ROOF STRUCTURE TO ACCOMMODATE THE REMOVAL OF EXISTING CEILING AND THE INSTALLATION OF NEW CEILING. REINSTALL ALL EXISTING CEILING MOUNTED SMOKE DETECTORS ON THE NEW CEILINGS, IN
THE SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE REMOVED.
REMOVE CEILING MOUNTED DIFFUSER. EXISTING MECHANICAL EQUIPMENT AND MATERIAL TO REMAIN. SEE " EXISTING CEILING DIFFUSER INSTALLATION DETAIL " ON DRAWING E002 FOR ADDITIONAL INFORMATION.
CEILING MOUNTED HVAC CONCENTRIC AIRFLOW UNIT TO REMAIN IN PLACE.
REMOVE CEILING MOUNTED FANS ALONG WITH ITS ASSOCIATED BRANCH CIRCUITRY BACK TO ITS SOURCE
OF CONTROL. REMOVE CONTROL SWITCH AND PROVIDE BLANK COVERPLATE ON OUTLET BOX.
REMOVE EXHAUST FAN GRILL. FAN TO REMAIN FOR REUSE.
REMOVE CEILING MOUNTED BATTERY PACKS WITH LAMP HEADS. REMOVE BRANCH CIRCUITRY BACK TO
POINT OF ORIGIN.
DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES IN CORRIDORS. SAVE ALL BRANCH
CIRCUITRY FOR REUSE.
SAVE FOR REUSE ALL LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY CONTROLLING CORRIDORS LIGHT FIXTURES. CONTRACTOR SHALL MAINTAIN EXISTING LIGHTING CONTROL SEQUENCE IN ALL
CORRIDORS.
REMOVE ALL EXIT LIGHT FIXTURES SHOWN ON THIS DRAWING. SAVE BRANCH CIRCUITRY FOR REUSE.
DISCONNECT AND REMOVE ALL PENDANT MOUNTED LIGHT FIXTURES SHOWN IN THIS SPACE. REMOVE ALL BRANCH CIRCUITRY BETWEEN LIGHT FIXTURES. SAVE HOMERUN BRANCH CIRCUITRY INTO THIS SPACE FOR
REUSE.
REMOVE LIGHT SWITCH AND SWITCH LEG CONDUCTORS. SAVE OUTLET BOX AND CONDUIT FOR REUSE.
(THIS DRAWING ONLY)
10 11 12
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
M
AT
C H
LI
N
E A
M
AT
C H
LI
N
E B
MATCHLINE B
MATCHLINE D
S S
SS
S S
S
S
S S
S
S
S
S
S
S
S
S
WA
LIBRARY
MAIN OFFICE
ROOM 1ROOM 2ROOM 3
ROOM 5
ROOM 7
ROOM 8
GIRLS ROOM
ROOM 4
ROOM 6
COURTYARD
OASIS
ROOM
ROOM 14
COURTYARD
GUIDANCE
CONFERENCE
ROOM
ROOM 18ROOM 16
ROOM
JANITOR 2
555555555
5 5 5
5 5 5 5
5 1
1212121212
1 1
1 1 1
8 8 88
S
1 1
WA
WA
WA
S E
SE
S E
S E
SESE
SE
SESE
SE
S E
3 SE
SE
SE
SE 3
SESESE
SE
SE
S E
S E
SE 3
SE
3SE3
S E
SE
SESE SE3
S E
SE
S E S E
S E S E
S E
S E
S E
SE SE
S E S E
S E S E
S E
SE
S E S E
SE
S E S E
SE
7 7
S E S E S E
7 7 7 7
SESE
SESE
SESE
S E S E
S E
WA
WA
WA
S E S E
S E
TEACHER'S
LOUNGE
SE
S E
S E
S ES E
S E S E
SE
SE
SE
S E
SE
SE
SESESE
S E
SE
WA
SESESE
S E
S E
S E 7
SE
SESESESE SESE
6 6 6
S E7
SESE
AC
AC
S S
S S
S
WA
H V
A C
5555 6
S E
SE
S S
S S S S
AC
WA 2
SE 3
SE
3 3
SE
S E
FLOOR PLAN - AREA B - LIGHTING AND AUXILIARY SYSTEMS - DEMOLITION
SCALE: 1/8" = 1'-0"
ED102
FL
O
O R
P
LA
N
AR
EA
B
LI
G
H
TI
N G
D
EM
O
LI
TI
O N
DEMOLITION NOTES:
1 DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES
SHOWN IN THIS SPACE. REMOVE ALL BRANCH CIRCUITRY BETWEEN
LIGHT FIXTURES. SAVE HOMERUN BRANCH CIRCUITRY INTO THIS
SPACE FOR REUSE.
REMOVE SURFACE/PENDANT MOUNTED LIGHT FIXTURE. SAVE
BRANCH CIRCUITRY FOR REUSE.
LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY TO REMAIN.
CONTRACTOR SHALL MAINTAIN EXISTING LIGHTING CONTROL
SEQUENCE IN THIS SPACE.
DISCONNECT AND REMOVE ALL CEILING MOUNTED SPEAKERS,
SECURITY CAMERAS, WIRELESS ACCESS DEVICES, AND MOTION
DETECTORS SHOWN ON THIS DRAWING, U.O.N., AND SAVE FOR REUSE.
SAVE ALL CABLES FOR REUSE. THE CONTRACTOR SHALL LABEL EACH
EQUIPMENT/DEVICE WITH REGARDS TO ROOM NUMBER AND LOCATION
TO ENSURE EACH EQUIPMENT IS REINSTALLED IN THE NEW CEILINGS
IN THE SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE
REMOVED. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING FOR
EACH SECURITY CAMERA:
a. LABEL AND DOCUMENT EACH EQUIPMENT LOCATION AND
ORIENTATION.
b. T-GRID HANGER BRACKET AND BOX WITH SCREW SHALL BE
KEPT AND REUSED AT TIME OF REINSTALLATION.
c. CAMERAS AND ALL OTHER DEVICES SHALL BE INSTALLED IN
SAME AREA AND IN THE SAME ORIENTATION AS ORIGINAL.
d. CAMERA REINSTALLATION SHALL TAKE INTO ACCOUNT ANY
NEW OBSTRUCTIONS THAT IMPACT THE LOCATION AND/OR
THE VIEWABLE AREA OF THE CAMERA SUCH AS LIGHTS AND
EXIT SIGNS.
e. IF CAMERA LENS NEEDS TO BE ADJUSTED, THE CONTRACTOR
SHALL WORK WITH SUFFOLK COUNTY SCHOOL TECHNOLOGY
STAFF TO REALIGN.
TEMPORARY SUPPORT ALL CEILING MOUNTED SMOKE DETECTOR
DEVICES SHOWN ON THIS DRAWING FROM EXISTING ROOF
STRUCTURE TO ACCOMMODATE THE REMOVAL OF EXISTING CEILING
AND THE INSTALLATION OF NEW CEILING. REINSTALL ALL EXISTING
CEILING MOUNTED SMOKE DETECTORS ON THE NEW CEILINGS, IN THE
SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE
REMOVED.
REMOVE CEILING MOUNTED DIFFUSER. EXISTING MECHANICAL
EQUIPMENT AND MATERIAL TO REMAIN. SEE " EXISTING CEILING
DIFFUSER INSTALLATION DETAIL " ON DRAWING E002 FOR ADDITIONAL
INFORMATION.
CEILING MOUNTED HVAC CONCENTRIC AIRFLOW UNIT TO REMAIN IN
PLACE.
REMOVE CEILING MOUNTED FANS ALONG WITH ITS ASSOCIATED
BRANCH CIRCUITRY BACK TO ITS SOURCE OF CONTROL. REMOVE
CONTROL SWITCH AND PROVIDE BLANK COVERPLATE ON OUTLET BOX.
REMOVE LIGHT SWITCH AND SWITCH LEG CONDUCTORS. SAVE
OUTLET BOX AND CONDUIT FOR REUSE.
DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES
IN CORRIDORS. SAVE ALL BRANCH CIRCUITRY FOR REUSE.
SAVE FOR REUSE ALL LIGHT SWITCH(ES) AND SWITCH LEG BRANCH
CIRCUITRY CONTROLLING CORRIDORS LIGHT FIXTURES.
CONTRACTOR SHALL MAINTAIN EXISTING LIGHTING CONTROL
SEQUENCE IN ALL CORRIDORS.
REMOVE ALL EXIT LIGHT FIXTURE SHOWN ON THIS DRAWING. SAVE
BRANCH CIRCUITRY FOR REUSE.
DISCONNECT AND REMOVE ALL PENDANT MOUNTED LIGHT FIXTURES
SHOWN IN THIS SPACE. REMOVE ALL BRANCH CIRCUITRY BETWEEN
LIGHT FIXTURES. SAVE HOMERUN BRANCH CIRCUITRY INTO THIS
SPACE FOR REUSE.
(THIS DRAWING ONLY)
4 9 10 11
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
MATC
HLIN
E A
MATC
HLIN
E C
M
AT
C H
LI
N
E C
S
S
CAFETERIA
KITCHEN
ROOM 11
ROOM 12 ROOM 13
POD 1
POD 2
SHOP ROOM 17
ROOM 15
MENS
HANDICAP
ROOM 19B
ORCHESTRA
ROOM 19
STORAGE
1 1
8 8 8
8 8
SE
SE SE SE
SE
SE
S E
SE
S E S E
S E S E
S E
SE
S E
WA
S E3
SE SE
SE SE SE SE
SE
S E
SE
SE
3 S E S E 7
SESE
SE
SE
S E8
SESESESESE
SESE
S E
PANTRY
SESESE
S E
SE
SE
SHOP ROOM 15 11
SESESESESESE
S E
S E S E
S E
SESESES SESE
3 3 3 3
SE
8 8
HIGH
VOLTAGE
XFMRS
SE
11 2 11 11
SE
11111111
S E
S
SS
S S
S
S E 3
FLOOR PLAN - AREA C - LIGHTING AND AUXILIARY SYSTEMS - DEMOLITION
SCALE: 1/8" = 1'-0"
ED103
FL
O
O R
P
LA
N
AR
EA
C
LI
G
H
TI
N G
D
EM
O
LI
TI
O N
DEMOLITION NOTES: (THIS DRAWING ONLY)
1 DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES SHOWN IN THIS
SPACE. REMOVE ALL BRANCH CIRCUITRY BETWEEN LIGHT FIXTURES. SAVE HOMERUN
BRANCH CIRCUITRY INTO THIS SPACE FOR REUSE.
REMOVE ALL SURFACE/PENDANT MOUNTED LIGHT FIXTURES. SAVE BRANCH
CIRCUITRY FOR REUSE.
LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY TO REMAIN. CONTRACTOR
SHALL MAINTAIN EXISTING LIGHTING CONTROL SEQUENCE IN THIS SPACE.
DISCONNECT AND REMOVE ALL CEILING MOUNTED SPEAKERS, SECURITY CAMERAS,
WIRELESS ACCESS DEVICES, SMOKE DETECTORS, AND MOTION DETECTORS SHOWN
ON THIS DRAWING, U.O.N., AND SAVE FOR REUSE. SAVE ALL CABLES FOR REUSE. THE
CONTRACTOR SHALL LABEL EACH EQUIPMENT/DEVICE WITH REGARDS TO ROOM
NUMBER AND LOCATION TO ENSURE EACH EQUIPMENT/DEVICE IS REINSTALLED IN THE
NEW CEILINGS IN THE SAME OR APPROXIMATE LOCATION FROM WHICH THEY WERE
REMOVED. THE CONTRACTOR SHALL PROVIDE THE FOLLOWING FOR EACH SECURITY
CAMERA:
a. LABEL AND DOCUMENT EACH EQUIPMENT LOCATION AND ORIENTATION.
b. T-GRID HANGER BRACKET AND BOX WITH SCREW SHALL BE KEPT AND REUSED AT
TIME OF REINSTALLATION.
c. CAMERAS AND ALL OTHER DEVICES SHALL BE INSTALLED IN SAME AREA AND IN
THE SAME ORIENTATION AS ORIGINAL.
d. CAMERA REINSTALLATION SHALL TAKE INTO ACCOUNT ANY NEW OBSTRUCTIONS
THAT IMPACT THE LOCATION AND/OR THE VIEWABLE AREA OF THE CAMERA SUCH AS
LIGHTS AND EXIT SIGNS.
e. IF CAMERA LENS NEEDS TO BE ADJUSTED, THE CONTRACTOR SHALL WORK WITH
SUFFOLK COUNTY SCHOOL TECHNOLOGY STAFF TO REALIGN.
TEMPORARY SUPPORT ALL CEILING MOUNTED SMOKE DETECTOR DEVICES SHOWN ON
THIS DRAWING FROM EXISTING ROOF STRUCTURE TO ACCOMMODATE THE REMOVAL
OF EXISTING CEILING AND THE INSTALLATION OF NEW CEILING. REINSTALL ALL
EXISTING CEILING MOUNTED SMOKE DETECTORS ON THE NEW CEILINGS, IN THE SAME
OR APPROXIMATE LOCATION FROM WHICH THEY WERE REMOVED.
REMOVE CEILING MOUNTED DIFFUSER. EXISTING MECHANICAL EQUIPMENT AND
MATERIAL TO REMAIN, U.O.N SEE " EXISTING CEILING DIFFUSER INSTALLATION DETAIL "
ON DRAWING E002 FOR ADDITIONAL INFORMATION.
DISCONNECT AND REMOVE ALL RECESSED MOUNTED LIGHT FIXTURES IN CORRIDORS.
SAVE ALL BRANCH CIRCUITRY FOR REUSE.
CEILING MOUNTED HVAC CONCENTRIC AIRFLOW UNIT TO REMAIN IN PLACE.
REMOVE CEILING MOUNTED FANS ALONG WITH ITS ASSOCIATED BRANCH CIRCUITRY
BACK TO ITS SOURCE OF CONTROL. REMOVE CONTROL SWITCH AND PROVIDE BLANK
COVERPLATE ON OUTLET BOX.
SAVE FOR REUSE ALL LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY
CONTROLLING CORRIDORS LIGHT FIXTURES. CONTRACTOR SHALL MAINTAIN EXISTING
LIGHTING CONTROL SEQUENCE IN ALL CORRIDORS.
REMOVE ALL EXIT LIGHT FIXTURES SHOWN ON THIS DRAWING. SAVE BRANCH
CIRCUITRY FOR REUSE.
ALL LIGHT FIXTURES SHOWN IN THIS SPACE ARE EXISTING TO REMAIN. REMOVE AND
REPLACE ALL EXISTING INCANDESCENT LAMPS WITH LED OF EQUAL LUMENS OUTPUT.
CONTRACTOR SHALL FIELD VERIFY ALL LAMPS WATTAGE AND LUMENS.
4 6 9 10
M
AT
C H
LI
N
E D
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
MATCHLINE B
MATCHLINE D
M
AT
C H
LI
N
E C
M
AT
C H
LI
N
E D
S S S S
S
S
SSSSS S S
S
WA
WA
AUDITORIUM
GYMNASIUM
ROOM 10 ROOM 9
BOYS LOCKERGIRLS LOCKER
STAGE
GIRLS ROOM BOYS ROOM
RESOURCE
OFFICE
2 2
WAWA
SESE
S E
SE
S E
S E
SE
SE
SESE
SE
SE
S E
S E
SE
S E
S E
16 S E S E
S E
SE
SE
8TH
GRADE
SE
SESESE
SE
S E S E
S E S E
S E
S E
SE
S E
SE
SE
S E S E
S E
SE
SE
S E
SE
SE
SE
SE
S E
SE
S E
GYM PANEL
S E
S E
SE
SE
14 14
S S
S S
SS
S
EF EF
S E
SE
3 3
MD
17 17
555555
FLOOR PLAN - AREA D - LIGHTING AND AUXILIARY SYSTEMS - DEMOLITION
SCALE: 1/8" = 1'-0"
ED104
FL
O
O R
P
LA
N
AR
EA
D
LI
G
H
TI
N G
D
EM
O
LI
TI
O N
DEMOLITION NOTES: (THIS DRAWING ONLY)
1 EXISTING LIGHT FIXTURE TO REMAIN. REMOVE AND
REPLACE ALL EXISTING INCANDESCENT / FLUORESCENT
LAMP WITH LED OF EQUAL LUMENS OUTPUT.
CONTRACTOR SHALL FIELD VERIFY ALL LAMPS
WATTAGE AND LUMENS.
REMOVE SURFACE/PENDANT MOUNTED LIGHT FIXTURE.
SAVE BRANCH CIRCUITRY FOR REUSE.
LIGHT SWITCH(ES) AND SWITCH LEG BRANCH CIRCUITRY
TO REMAIN. CONTRACTOR SHALL MAINTAIN EXISTING
LIGHTING CONTROL SEQUENCE IN THIS SPACE.
DISCONNECT AND REMOVE ALL CEILING MOUNTED
SPEAKERS, SECURITY CAMERAS, WIRELESS ACCESS
DEVICES, AND MOTION DETECTORS SHOWN ON THIS
DRAWING, U.O.N., AND SAVE FOR REUSE. SAVE ALL
CABLES FOR REUSE. THE CONTRACTOR SHALL LABEL
EACH EQUIPMENT/DEVICE WITH REGARDS TO ROOM
NUMBER AND LOCATION TO ENSURE EACH
EQUIPMENT/DEVICE IS REINSTALLED IN THE NEW
CEILINGS IN THE SAME OR APPROXIMATE LOCATION
FROM WHICH THEY WERE REMOVED. THE CONTRACTOR
SHALL PROVIDE THE FOLLOWING FOR EACH SECURITY
CAMERA:
a. LABEL AND DOCUMENT EACH EQUIPMENT
LOCATION AND ORIENTATION.
b. T-GRID HANGER BRACKET AND BOX WITH SCREW
SHALL BE KEPT AND REUSED AT TIME OF
REINSTALLATION.
c. CAMERAS AND ALL OTHER DEVICES SHALL BE
INSTALLED IN SAME AREA AND IN THE SAME
ORIENTATION AS ORIGINAL.
d. CAMERA REINSTALLATION SHALL TAKE INTO
ACCOUNT ANY NEW OBSTRUCTIONS THAT IMPACT
THE LOCATION AND/OR THE VIEWABLE AREA OF
THE CAMERA SUCH AS LIGHTS AND EXIT SIGNS.
e. IF CAMERA LENS NEEDS TO BE ADJUSTED, THE
CONTRACTOR SHALL WORK WITH SUFFOLK
COUNTY SCHOOL TECHNOLOGY STAFF TO
REALIGN.
TEMPORARY SUPPORT ALL CEILING MOUNTED SMOKE
DETECTOR U.O.N., DEVICES SHOWN ON THIS DRAWING
FROM EXISTING ROOF STRUCTURE TO ACCOMMODATE
THE REMOVAL OF EXISTING CEILING AND THE
INSTALLATION OF NEW CEILING. REINSTALL ALL
EXISTING CEILING MOUNTED SMOKE DETECTORS ON
THE NEW CEILINGS, IN THE SAME OR APPROXIMATE
LOCATION FROM WHICH THEY WERE REMOVED.
REMOVE CEILING MOUNTED DIFFUSER. EXISTING
MECHANICAL EQUIPMENT AND MATERIAL TO REMAIN,
U.O.N SEE "EXISTING CEILING DIFFUSER INSTALLATION
DETAIL" ON DRAWING E002 FOR ADDITIONAL
INFORMATION.
DISCONNECT AND REMOVE ALL RECESSED MOUNTED
LIGHT FIXTURES IN CORRIDORS. SAVE ALL BRANCH
CIRCUITRY FOR REUSE.
CEILING MOUNTED HVAC CONCENTRIC AIRFLOW UNIT TO
REMAIN IN PLACE.
REMOVE CEILING MOUNTED FANS ALONG WITH ITS
ASSOCIATED BRANCH CIRCUITRY BACK TO ITS SOURCE
OF CONTROL. REMOVE CONTROL SWITCH AND PROVIDE
BLANK COVERPLATE ON OUTLET BOX.
SAVE FOR REUSE ALL LIGHT SWITCH(ES) AND SWITCH
LEG BRANCH CIRCUITRY CONTROLLING CORRIDORS
LIGHT FIXTURES. CONTRACTOR SHALL MAINTAIN
EXISTING LIGHTING CONTROL SEQUENCE IN ALL
CORRIDORS.
REMOVE ALL EXIT LIGHT FIXTURES SHOWN ON THIS
DRAWING. SAVE BRANCH CIRCUITRY FOR REUSE.
REMOVE ALL PENDANT MOUNTED LIGHT FIXTURES IN THE
GYMNASIUM. SAVE ALL BRANCH CIRCUITRY FOR REUSE.
EXISTING PANELS SERVING GYMNASIUM LIGHT
FIXTURES TO REMAIN.
REMOVE ALL LIGHT FIXTURES IN THE AUDITORIUM
LAY-IN TILE CEILING AND SAVE FOR REUSE. SAVE
BRANCH CIRCUITRY FOR REUSE.
EXISTING CEILING MOUNTED LIGHT FIXTURE AND
BRANCH CIRCUITRY TO REMAIN.
EXISTING LIGHT FIXTURE IN THIS SPACE TO REMAIN.
REMOVE AND REPLACE ALL EXISTING INCANDESCENT
LAMP WITH LED OF EQUAL LUMENS OUTPUT.
REMOVE LIGHT SWITCH AND SWITCH LEG CONDUCTORS.
PROVIDE BLANK COVERPLATE ON OUTLET BOX.
REMOVE EXHAUST FAN GRILL. FAN TO REMAIN FOR
REUSE.
EXISTING SMOKE DETECTOR TO REMAIN.
4 6 9 10
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
CP101
FL
O
O R
P
LA
N
AR
EA
A
R
EF
LE
C
TE
D
C
EI
LI
N
G
N
EW
W O
R K
FLOOR PLAN - AREA A - REFLECTED CEILING - NEW WORK
SCALE: 1/8" = 1'-0"
NEW WORK NOTES:
1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.
M
AT
C H
LI
N
E A
M
AT
C H
LI
N
E B
MATC
HLIN
E A
MATC
HLIN
E C
WA
WA
WA
WA
WA
ACAC
ACAC
AC
WA
OS
OS OS
WA
WA
WA
WA
WA
WA
WA
WAWA
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
ROOM 23
ROOM 21
ROOM 48
ROOM 29
ROOM 39
ROOM 49
ROOM 38
ROOM 47
ROOM 36 ROOM 45
ROOM 34
ROOM 43
ROOM 32
ROOM 41
ROOM 46
ROOM 44
ROOM 42
ROOM 40
ROOM 30
GIRLS ROOM
BOYS ROOM
STORAGE
STORAGE
ROOM 20
STORAGE ROOM
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
ACAC
ACAC
AC
AC
AC
AC
AC
S
S
S
S
S
S
S
S
S S
S S
S
S
S
S
S
S
CLINIC
WA
OS
S E
S E
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
ROOM 27
ROOM 26
ROOM 25
ROOM 24
S E S E
S E
OS
OS
OS
S
OS
OS
OS
NEW BULKHEAD
NEW
BULKHEAD
NEW BULKHEAD NEW BULKHEAD
MTL STUD CROSS
BRACING @ 4'-0" OC
MAX
1/2" GYP BD OR
FIELD VERIFIED
3 5/8" MTL STUDS @
16" O.C. FASTEN
STRUCT ABOVE
4' 5/8"
4'- 0"
4'- 0"
SAPC - REF
FIN SCHED
TYPICAL NEW BULKHEAD DETAIL
NOT TO SCALE
THE EXISTING CEILING HEIGHT IS SHOWN.
CONTRACTOR SHALL ADJUST AS
NECESSARY WHERE VERIFIED FIELD
CONDITIONS VARY DUE TO CHANGE IN
ELEVATIONS FROM ONE SIDE TO
ANOTHER
(THIS DRAWING ONLY)
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
M
AT
C H
LI
N
E A
M
AT
C H
LI
N
E B
MATCHLINE B
MATCHLINE D
WA
OS OS
OS
OS
OS
OS
OS
OS
OS OSOS
LIBRARY
MAIN OFFICE
ROOM 1ROOM 2
ROOM 3
ROOM 5
ROOM 7
ROOM 8
GIRLS ROOM
ROOM 4
ROOM 6
COURTYARD
OASIS
ROOM
ROOM 14
COURTYARD
GUIDANCE
CONFERENCE
ROOM
ROOM 18ROOM 16
ROOM 14A
AC
AC
AC
AC
AC
AC
S S
SS
S
S
S
SS S
S
S
S
S
S
S
S
S
MD
WA
OS
OS
OSSD
OS
OS
OS
OS
S
TEACHER'S
LOUNGE
SE
OS
S S
S S
S
WA
OS
OS
NEW BULKHEADNEW BULKHEAD
NEW
BULKHEAD
NEW BULKHEAD
NEW BULKHEAD
NEW BULKHEAD
WA
FLOOR PLAN - AREA B - REFLECTED CEILING - NEW WORK
SCALE: 1/8" = 1'-0"
CP102
FL
O
O R
P
LA
N
AR
EA
B
R
EF
LE
C
TE
D
C
EI
LI
N
G
N
EW
W O
R K
NEW WORK NOTES:
1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.
(THIS DRAWING ONLY)
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
/0
4/
9:
:0
BI
M
8-
C
C
PS
N ew
M id dl e
Sc ho ol /1
-0 v2
C C
PS
N ew M
S
- A
R C
H .rv t
J
U N
E
XX
XX
X-
XX
PA M
W
H
KC
JO
H
N Y
EA
TE
S M
ID
D
LE
S
C H
O O
L
SU
FF
O
LK
P
U
BL
IC
S
C H
O O
LS
SU
FF
O
LK
, V
IR
G
IN
IA
B
EN
N
ET
TS
P
AS
TU
R E
R O
AD
KEY PLAN
NOT TO SCALE
AB
C
D
THOMPSON
Consulting Engineers
4411 COX ROAD
2809 S. LYNNHAVEN ROAD VA BEACH, VA 23452
GLEN ALLEN, VA 23060
TELEPHONE: (757) 599-4415 PROJECT NUMBER: 22-109
22 ENTERPRISE PARKWAY HAMPTON, VA 23666
MATC
HLIN
E C
M
AT
C H
LI
N
E C
M
AT
C H
LI
N
E D
WA
AC
AC
S
S
OS
S
OS OSOS
OS OS OS
OS
OS
OS
FLOOR PLAN - AREA C - REFLECTED CEILING - NEW WORK
SCALE: 1/8" = 1'-0"
CP103
FL
O
O R
P
LA
N
AR
EA
C
R
EF
LE
C
TE
D
C
EI
LI
N
G
N
EW
W O
R K
CAFETERIA
KITCHEN
ROOM 11 ROOM 12 ROOM 13
POD 1
POD 2
SHOP ROOM 17
ROOM 15
MENS
HANDICAP
ROOM 19B
ROOM 19A
STORAGE
NEW WORK NOTES: (THIS DRAWING ONLY)
1 REFER TO GENERAL DEMOLITION AND NEW WORK NOTES ON DRAWING CPD101.
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .