This is a technical specification document for a supply contract issued by Jefferson Parish, Louisiana for the Departments of Water, Sewerage, and other parish agencies and municipalities. The contract covers the supply of three types of PVC pipe: C-900 PVC Pressure Pipe (4" through 36"), Heavy Wall PVC Sewer Pipe SDR-26 (4" through 18"), and PVC Pipe SDR 35/PS 115 (15" through 30"). The contract has a one-year term, with actual usage on an as-needed basis rather than fixed quantities. The successful contractor must deliver products to two warehouse locations: the Public Works East Bank Warehouse at 4901 Jefferson Highway, Jefferson, LA 70123, and the Public Works West Bank Warehouse at 1500 River Park Road, Bridge City, LA 70094. Bid prices shall include all freight and delivery costs to these locations. The specification document does not identify specific response dates, bid due dates, site visits, bidders' conferences, or award dates.

All supplied products must comply with applicable ASTM and AWWA standards, including specific cell classifications, joint specifications, gasket materials, pipe dimensions, and wall thickness requirements detailed for each pipe type. Products are warranted for one year after delivery and must be free from defects in workmanship and materials, with any defective items replaced at no cost to the purchaser. The pipe shall be furnished in standard 20-foot laying lengths for C-900 and in 14-foot and 20-foot lengths for SDR-26 and SDR 35/PS 115 pipes, and must bear manufacturer identification markings at specified intervals. The document contains no information regarding pricing terms, set-asides, incumbent contractors, funding sources, or amounts.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C-900 PVC Pressure Pipe, Heavy Wall PVC (SDR-26) Sewer Pipe and PVC (SDR 35/PS 115) Pipe

Contract

Items included in this contract:

1. PVC Pressure Pipe (C-900), (4" through 36").

2. Heavy Wall PVC Sewer Pipe (SDR 26), (4" through 18")

3. PVC Pipe (SDR 35/PS 115), (15" through 30")

Contract Terms:

This is a one (1) year contract for supply of C-900 PVC Pressure Pipe, Heavy Wall PVC Sewer Pipe and PVC Pipe (SDR 35), for the Departments of Water, Sewerage, and other Jefferson Parish agencies and municipalities.

Warranty:

Products shall be warranted that they are manufactured in accordance with the applicable material specifications and are free from defects in workmanship and materials for one year after delivery. Any defective items sold under this contract shall be replaced at no cost to the purchaser.

General Specifications:

This specification designates the general requirements for C-900 PVC Pressure Pipe, Heavy Wall PVC Sewer Pipe and PVC Pipe (SDR 35), (pipe with integral wall bell and spigot joints) for the conveyance of potable water and domestic sewerage.

The quantities shown on the proposal guide are approximate quantities to be acquired by Jefferson Parish over a one (1) year period. Actual usage will be on an “as needed” basis.

Bid price shall include all freight and delivery costs to Jefferson Parish warehouse locations on the East and West Banks of Jefferson Parish.

The successful contractor shall deliver the product to the below addresses:

Public Works EB Warehouse

4901 Jefferson Hwy.

Jefferson, LA. 70123

Public Works WB Warehouse

1500 River Park Rd.

Bridge City, LA. 70094

Technical Specifications (C-900):

I. Pipe:

Polyvinyl chloride (PVC) pressure pipe shall conform to the latest revision AWWA C- 900 polyvinyl chloride pipe shall conform to ASTM 1784 or latest revisions. Polyvinyl chloride (PVC) pressure pipe shall be available in 4-inch through 24-inch sizes, and shall have a maximum dimension ratio (DR) of 18 (min pressure rating of 235 psi and minimum pipe stiffness of 364 psi).

Polyvinyl chloride (PVC) pressure pipe shall conform to the latest revision of AWWA standard C-900. Polyvinyl chloride (PVC) shall be available in sizes of 36 inches, shall have a maximum dimension ratio (DR) of 25 (min pressure rating of 165 psi and minimum pipe stiffness of 129 psi).

The pipe shall be furnished in standard 20-foot laying lengths. Each length of pipe shall be marked with the name of the manufacturer, size and class.

Pipe shall be guaranteed against defects in workmanship and materials for a period of one

(1) year from date of delivery.

II. Cell Classification:

Pipe shall be made of PVC plastic having cell classification 12454 as defined in the ASTM D1784 specification.

III. Joints:

The gasket joint shall meet the requirements of ASTM D3139.

IV. Gaskets:

Material used for elastomeric seal in push-on joint shall meet ASTM F477.

V. Pipe Dimensions and Minimum Wall Thickness

Nominal Size

Average O.D. Min. Wall Thickness

4" (C-900) 4.800" 0.267" 6" (C-900) 6.900" 0.383" 8" (C-900) 9.050" 0.503" 10"(C-900) 11.100" 0.617" 12"(C-900) 13.200" 0.733" 14"(C-900) 15.300 0.850" 16"(C-900) 17.400 0.967" 18"(C-900) 19.500 1.083" 20"(C-900) 21.600 1.200" 24"(C-900) 25.800 1.433" 36"(C-900) 38.300 1.532"

VI. Markings:

Pipe shall bear identification markings that will remain legible during normal handling, storage, and installation. The markings shall be applied in a manner that will not reduce the strength of the pipe.

Technical Specifications (SDR 26):

Pipes 4 inches through 15 inches in diameter shall meet ASTM specification D-3034-08, DR26 with minimum pipe stiffness of 115 PSI. Pipes larger than 15 inches in diameter shall meet ASTM specification F-679-08, with minimum pipe stiffness of 115 PSI.

Pipe sections shall be integral cast bell and elastomeric gasket as recommended by the manufacturer and ASTM specification D-3212 for push-on joints.

Pipes shall be delivered in 14' and 20' lengths and in green color.

II. Basic Materials:

Pipe shall be made of PVC plastic having cell classifications as defined in ASTM D1784 specification.

Pipe sections shall be integral cast bell and elastomeric gasket as recommended by the

Material used for the elastomeric seal in push-on joint shall meet either ASTM F477 or F913.

V. Pipe Dimensions and Minimum Wall Thickness:

Nominal Size 4" 6" 8" 10" 12" 15" 18"

Average

OD

4.215" 6.275" 8.400" 10.500" 12.500" 15.300 18.701

Min. Wall Thickness

0.162" 0.241" 0.323" 0.404" 0.481" 0.588" 0.719"

• Pipe Markings:

Each standard and random length of pipe in compliance with this specification shall be clearly marked with the following information at intervals of 5 ft. (1.5 m) or less.

• Manufacturer's name or trademark and code.

• Nominal pipe size.

• PVC minimum cell classification.

• Pipe stiffness designation of “PS 115 PVC Sewer Pipe”.

• ASTM designation of “ASTM F679”.

Technical Specifications (SDR 35/PS 115):

Pipes 15 inches through 30 inches in diameter shall meet ASTM specification D-3034- 08, DR35/PS 115 with minimum pipe stiffness of 115 PSI. Pipes larger than 15 inches in diameter shall meet ASTM specification F-679-08, with minimum pipe stiffness of 115

PSI.

Pipe sections shall be integral cast bell and elastomeric gasket as recommended by the

Pipes shall be delivered in 14' and 20' lengths and in green color.

II. Basic Materials:

Pipe shall be made of PVC plastic having cell classifications as defined in ASTM D1784 specification.

Pipe sections shall be integral cast bell and elastomeric gasket as recommended by the

Material used for the elastomeric seal in push-on joint shall meet either ASTM F477 or F913.

V. Pipe Dimensions and Minimum Wall Thickness:

Nominal Size Average OD Min. Wall Thickness 15" 15.300" 0.437" 24" 24.803" 0.889" 30" 32.000" 1.148"

• Pipe Markings:

Each standard and random length of pipe in compliance with this specification shall be clearly marked with the following information at intervals of 5 ft. (1.5 m) or less.

• Manufacturer's name or trademark and code.

• Nominal pipe size.

• PVC minimum cell classification.

• Pipe stiffness designation of “PS 115 PVC Pipe”.

• ASTM designation of “ASTM F679”.