JA3 - FTQW 17-1015 Final Const Drawings 22x34 25 AUG 22.pdf
PDF 41 MB Posted
- Solicitation number
- FA500422B0013
About this file
This federal contract opportunity solicitation seeks proposals for the renovation of the Combat Alert Cell at Building 1300 at a Department of the Air Force Pacific Air Forces base. The solicitation number is FA500422B0013 and proposals are due by the date specified in the attached solicitation and five attachments. Renovation work includes updating the Combat Alert Cell facility to current standards. The award is expected to be a firm-fixed price contract issued before the end of 2022.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 View Name 1/8" = 1'-0"A101
Room name
GENERAL SYMBOLS
NAME
NUMBER
SHEET LOCATION
SCALE
TRUE NORTH
GRID LINE
ROOM NAME
ROOM NUMBER
PLAN NORTH
REVISION
SEE DISCIPLINES FOR SPECIFIC SYMBOLS
PROJECT TEAM
OWNER
354TH CIVIL ENGINEER SQUADRON
2310 CENTRAL AVENUE, BUILDING 2258
EIELSON AIR FORCE BASE, AK 99702
DESIGNER
DESIGN ALASKA
601 COLLEGE ROAD
FAIRBANKS, AK 99701
VICINITY MAP
PROJECT
LOCATION
BUILDING
R
ICH
ARD
SO
N
H
IG
H W
AY
MAIN ENTRY GATE
ALASKA MAP
PACIFIC OCEAN
ARCTIC OCEAN
BERING
SEA
KODIAK
ARCTIC CIRCLE
SEWARD
SITKA
JUNEAU
HAINES
WHITEHORSE YT
DAWSON YT
HAINES
JCT
HOMER
ANCHORAGE
EAGLE
CORDOVA
VALDEZ
GLENNALLEN
EIELSON
AFB
NENANA
TANANA CIRCLE
NOME
KOTZEBUE
UTQIAGVIK
(BARROW)
PRUDHOE BAY
U N
IT
ED
S
TA
TE
S
R U
SS
IA
U N
ITED
STATES
C
AN
AD
A
PROJECT
LOCATION
D ate
Project N o.
Architects Engineers
Surveyors 601 C ollege R oad Fairbanks AK 99701
907.452.1241 designalaska.com
AEC
C
Sht.
O f
354th C ivil Engineer Squadron
Eielson AFB, Alaska
Project Engineer
C hief Engineer
D raw n By
D esigned By
R eference
N o.
R ev
D escription
By D ate
22 A U G
FTQ
W
17-1015
R
EN
O
VATE C
O M
BAT ALER
T C
ELL (B1300)
COMM NUMBER: 022103 8/22/2022 3:40:18 PM
AJS
GENERAL INFORMATION
G
AJS
RENOVATE COMBAT ALERT CELL (B1300)
EIELSON AFB, ALASKA
354TH CIVIL ENGINEER SQUADRON
ARCHITECTURAL
A301 EXTERIOR ELEVATION - EAST AND SOUTH
A400 SECTION - BUILDING
A410 SECTION - WALL
A470 VERTICAL CIRCULATION - SECTIONS
A471 VERTICAL CIRCULATION - SECTIONS
A480 VERTICAL CIRCULATION - DETAILS
A500 EXTERIOR DETAILS - ASSEMBLY TYPE
A510 EXTERIOR DETAILS - TYPICAL
A551 EXTERIOR DETAILS - OPEN - DOOR
A552 EXTERIOR DETAILS - OPEN - WINDOW
A553 EXTERIOR DETAILS - OPEN - LOUVER
A554 EXTERIOR DETAILS - OPEN - SNOW HOOD
A555 EXTERIOR DETAILS - OPEN - O/H DOOR
A560 EXTERIOR DTL - WALL-ROOF TRANSITION
A580 EXTERIOR DETAIL - ROOF
A600 INTERIOR PLAN - ENLARGED
A610 INTERIOR PLAN - ACOUSTIC - CORE AREA
A622 INTERIOR PLAN - CEILING - CORE AREA
A631 INTERIOR PLAN - FINISH - STORAGE BAY
A632 INTERIOR PLAN - FINISH - SIGNAGE - CORE
A700 INTERIOR ELEVATION - ACCESSORY TYPE
A710 INTERIOR ELEVATION
A711 INTERIOR ELEVATION
A800 INTERIOR DETAILS - ASSEMBLY TYPE
A810 INTERIOR DETAILS
A811 INTERIOR DETAILS
A812 INTERIOR DETAILS
A813 INTERIOR DETAILS
A900 SCHEDULE AND TYPE - ROOM
A910 SCHEDULE AND TYPE - MATERIAL
A920 SCHEDULE AND TYPE - DOOR - WINDOW
A940 SCHEDULE AND TYPE - SIGNAGE
ARCHITECTURAL
A001 ARCHITECTURAL INFORMATION
A100 EXISTING PLAN - OVERALL
A111 DEMOLITION PLAN - STORAGE BAY
A112 DEMOLITION PLAN - CORE AREA
A121 DEMOLITION ROOF PLAN - APPARATUS
A122 DEMOLITION ROOF PLAN - CORE/ BAY
A211 RENOVATION PLAN - APPARATUS BAY
A212 RENOVATION PLAN - CORE AREA
A221 RENOVATION ROOF PLAN - APPARATUS
A222 RENOVATION ROOF PLAN - CORE/ BAY
A300 EXTERIOR ELEVATION - WEST AND NORTH
GENERAL
G001 GENERAL INFORMATION
G100 CODE INFORMATION
G101 CODE INFORMATION - OCCUPANCY
G110 CODE PLAN - OVERALL
G111 CODE PLAN - CORE - OCCUPANCY
G112 CODE PLAN - CORE - TRAVEL DISTANCE
G300 ELECTRICAL AREA CLASSIFICATION PLAN
STRUCTURAL
S001 STRUCTURAL GENERAL NOTES
S002 SPECIAL INSPECTIONS
S003 SPECIAL INSPECTIONS
S100 DEMOLITION PLAN - CORE AREA
S200 RENOVATION PLAN - CORE AREA
S210 RENOVATION PLAN - STORAGE BAYS
S211 RENOVATION PLAN - BAY 2
S400 HRV PLATFORM PLAN & DETAILS
S401 HRV PLATFORM DETAILS
S410 EXTERIOR STAIR STRUCTURAL PLAN
S411 EXTERIOR STAIR DETAILS
S500 OVERHEAD DOOR FRAMING
S501 CROSS BRACE REPAIRS
S510 WOOD, CFS, AND CONCRETE DETAILS
S511 WOOD, CFS, AND CONCRETE DETAILS
MECHANICAL
M303 REFRIGERANT PIPING PLANS
M310 HYDRONIC DIAGRAMS AND DETAILS
M401 PLUMBING PLANS
M402 1ST FLOOR PARTIAL PLUMBING PLAN
M404 UNDERFLOOR PLUMBING PLANS
M410 PLUMBING RISER DIAGRAMS AND DETAILS
MECHANICAL
M001 ABBREVIATIONS & LEGENDS
M002 MECHANICAL EQUIPMENT SCHEDULE
M003 MECHANICAL SCHEDULES
M101 VENTILATION DEMOLITION PLANS
M102 VENTILATION DEMOLITION ELEVATIONS
M103 HYDRONIC DEMOLITION PLANS
M104 PLUMBING DEMOLITION PLANS
M105 HEATING PLANT DEMOLITION DIAGRAM
M201 VENTILATION PLANS
M202 APPARATUS BAYS VENTILATION PLAN
M220 VENTILATION ELEVATIONS
M230 VENTILATION ELEVATIONS & DETAILS
M231 MECHANICAL DETAILS
M301 HYDRONIC PLANS
M302 ENLARGED BAY 3&4 HYDRONIC PLAN
ELECTRICAL
E001 LEGENDS SCHEDULES AND DETAILS
E002 POWER RISERS AND CALCULATIONS
E003 ADDITIONAL DETAILS
E101 LIGHTING DEMO PLANS
E102 POWER/SIGNAL DEMO PLANS
E200 LIGHTING PLANS
E300 POWER/SIGNAL PLANS
E500 PANEL SCHEDULES
E501 PANEL SCHEDULES
E502 PANEL SCHEDULES
E600 FIREFIGHTER ALERT SYSTEM PLANS
HAZARDOUS MATERIALS
H100 LOCATION MAPS, NOTES, LEGENDS, & ACRONYM KEY
H101 1ST FLOOR ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS
H102 2ND FLOOR ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS
H103 3RD FLOOR ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS
H104 BAY 3 & 4 ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS
H105 MECHANICAL ROOMS ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS
H106 LABORATORY REPORTS
H107 LABORATORY REPORTS
H108 LABORATORY REPORTS
H109 LABORATORY REPORTS
FIRE PROTECTION
F001 CODE COMPLIANCE SITE PLAN
F100 FIRE ALARM NOTES, LEGENDS, SYMBOLS
F101 FIRE ALARM DEMO OVERALL PLAN
F102 FIRE ALARM DEMO ENLARGED PLANS
F103 FIRE ALARM RENO OVERALL PLAN
F104 FIRE ALARM RENO ENLARGED PLANS
F200 FIRE SUPP. NOTES, LEGENDS, SYMBOLS
F201 FIRE SUPP. DEMO OVERALL PLAN
F202 FIRE SUPP. DEMO ENLARGED PLANS
F203 FIRE SUPP. RENO OVERALL PLAN
F204 FIRE SUPP. RENO ENLARGED PLANS
FTQW 17-1015
CIVIL
C200 SITE PLAN
C700 CIVIL DETAILS
CODE INFORMATION
SUPPORT / NOTES / CALCULATIONSAPPLICATION / REQUIREMENT
R-2 Residential S-2 Storage (Parking) S-1 Aircraft Hangar B Business
Use IBC Chapter 5
Building Height Limitations Section 504 Table 504.3 & 504.4 Section 508.4.3
Building Area Modifications IBC Section 506.2
PROJECT NAME:
AUTHORITY HAVING
JURISDICTION (AHJ):
GOVERNING CODES:
Fire-Resistance Rating for Exterior Walls Based on Fire Separation Distance IBC Table 602
Fire separation distance
Type VB - Separated Mixed Use - Fully Sprinklered
OCC ALLOWABLE ACTUAL
R-2
OCC ALLOWABLE
21,000 SF 26,250
Secondary means of escape per § 26.2.1.2 in accordance with § 24.2.2.. Per § 24.2.2.1.2(2) secondary means of escape is not required when fully sprinklered.
Building Area Limitations Section 506 Table 506.2
23,954 SF
Primary structural frame Interior bearing walls Exterior bearing walls Nonbearing walls and partitions *unless required by NFPA 101, see fire and smoke protection features below* Floor construction and secondary members
Roof construction and secondary members
Type VBBUILDING ELEMENT
TypeOccupancy Required rating
S-1, S-2, R-2, B X > 30 VB 0
See Occupancy Tabulation on Code Information - Occupancy Plan
IBC: Actual Floor Area by Occupancy First Floor
Second Floor
Third Floor
Total:
60'-0", 3 Stories
1,271 SF Group R-2 Occupancy
1,057 SF Group R-2 Occupancy
Group S-1 Occupancy
10,596 SF
Group R-2 Occupancy 1,213 SF
Building shall be fully sprinklered
Lodging or Rooming - Not required.
Industrial Special Purpose - Not required.
Storage (Ordinary Hazard) - Not required.
S-2 40,500 SF
60'-0", 2 StoriesS-1
50,625
Group
ALLOWABLE WITH
INCREASES
SUPPORT / NOTES / CALCULATIONSAPPLICATION / REQUIREMENT
Occ. Load UFC 3-600-01 Table 10-1 / NFPA 101
Minimum Egress Width
NFPA 101 § 7.3.4
Use UFC 3-600-01, 9-7
Dead End Corridor NFPA 101 - Chps. 26, 40, 42, and UFC 4-211-01
Max Travel Distance NFPA 101 - Chps. 26, 40, 42, and UFC 4-211-01
CHAPTER
UFC 1-200-01 2-3
Use and Occupancy Classification
UFC 1-200-01 2-4
Special Detailed Requirements Based on Use and Occupancy
UFC 1-200-01 2-5
General Building Heights and Areas
UFC 1-200-01 2-6
Types of Construction
Use IBC Chapter 3 and NFPA 101 via UFC 3-600-01
Use IBC Chapter 6 and UFC 3-600-01
Fire-Resistance Rating for Building Elements IBC Table 601
CHAPTER
UFC 1-200-01 2-8
Interior Finishes
Use UFC 3-600-01 and UFC 3-120-10
NFPA 101 Chp. 26, 40, 42 and Table A.10.2.2
UFC 1-200-01 2-9
Fire Protection Systems
Fire Extinguishers UFC
3-600-01, 9-17, NFPA
101, NFPA 10
Number of Exits
NFPA 101 § 7.4.1.1
UFC 1-200-01 2-10
Means of Egress
Use UFC 3-600-01
REFERENCE
REFERENCE
UFC 4-211-01 applies for Hangar Bays 1 & 2 per § 4-4.1 UFC 4-730-10 not addressed in UFC 3-600-01 however per SOW UFC applies to the greatest extent possible
Separated Mixed Use Building.
*Per NFPA 101 § 6.1.14.1.3 New Business is incidental to Lodging and Rooming House and areas shall be permitted to be considered part of the predominant (Lodging and Rooming House) occupancy and subject to the provisions that apply to the predominant occupancy.
Allowable Area Increase due to Frontage per 506.3
RENOVATE COMBAT ALERT CELL (B1300)
PACIFIC AIR FORCES (PACAF)
UFC 1-200-01 General Building Requirements (Change 1, 8 October 2019) UFC 3-600-01 Fire Protection Engineering for Facilities (Change 6, 6 May 2021) UFC 4-211-01 Aircraft Maintenance Hangars (Change 3, April 20, 2021) UFC 4-730-10 Fire Stations (Change 1, June 11, 2021) 2018 International Building Code (IBC), (as amended by UFC 1-200-01) 2021 NFPA 101- Life Safety Code 2019 Installation for Sprinkler Systems (NFPA) 13
CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE
PORTIONS OF THE GOVERNING CODES INCLUDING
REFERENCED CODES AND STANDARDS.
NOTE: PREVIOUS/ORIGINAL CODE ANALYSIS WAS
NOT PROVIDED FOR THIS RENOVATION. EXISTING
BUILDING INFORMATION FOR THIS ANALYSIS IS
DETERMINED FROM SITE OBSERVATION AND OWNER
PROVIDED INFORMATION / DRAWINGS.
NOTE: 'SECTION' IS REPLACED WITH
THE CHARACTER '§' THIS SHEET.
Fire Separation Distance Degree of Protection Allowable Area
30' or greater Unprotected, Sprinklered
Maximum Area of Exterior Wall Openings IBC Table 705.8 No Limit / Not Required No limit
UFC 1-200-01 2-7
Fire and Smoke Protection Features
IBC NFPA
Lodging or Rooming Houses Storage Ordinary Hazard Industrial Special Purpose New Business*
Lodging or Rooming Chp. 26, 10.2 Floor Class
Storage Chp. 42 Floor Class
Exits Exit Access Corridors Walls and Ceilings
Other Spaces
A, B, or C Minimum critical radiant flux of at least 0.1 W/cm2
A, B, or C A, B, or C Minimum critical radiant flux of at least
0.1 W/cm2
A or B I or II
A, B, or C I or II
A, B, or C
NA
Lodging § 26.2
Storage § 42.2.6
Not Required
400 ft.
Lodging § 26.2
Storage § 42.2.5
Not Required
100 ft.
Common Path of Travel NFPA 101 - Chps. 26, 40, 42, and UFC 4-211-01
Lodging § 26.2
Storage § 42.2.5
Not Required
100 ft.
Fire Alarm per UFC 3-600-01 and NFPA 101 / Mass Notification per UFC 4-010-01
Fire alarm required
Per § 9-7.2.1.2 Core area wet pipe system to be replaced. Remainder of building suppression system to remain as existing.
Group I and II Aircraft Hangar Roofs shall be FM Class 1 Roof Assembly per NFPA 409 § 7.6.2 and UFGS 07 54 19 § 1.3.1 a.
all PVC Roofing.
A, B, or C
Interior Walls / Ceilings
A, B, or C
Emergency Lighting NFPA 101 Chp. 7.8
Lodging Rooms per Chp. 7.8 Chp. 42 - Occupied Spaces only.
Provided at exit access and exits.
60'-0", 3 StoriesS-2
S-1 27,000 SF 33,750
Group S-2 Occupancy
9,169 SF
Industrial Special Purpose Chp. 40 Floor Class
A or B
I or II
A, B, or C
I or II
A, B, or C
NA
A, B, or C
Not required, but being provided in kitchen and laundry rooms per EAFB FD.
Industrial Special Purpose § 40.2.6.1
400 ft.
Hangars 150 ft. per
UFC 4-211-01
Bays 1 and 2 exiting per UFC 4-211-01 not evaluated as part of this project per the government
Industrial Special Purpose § 40.2.5.1
50 ft.
Industrial Special Purpose § 40.2.5.1
100 ft.
Occupancy Separations Per UFC 3-600-01 Use IBC Chapter 5
Interior Non- Load Bearing Partitions (Excluding Occupancy Separations) Per UFC 3-600-01 Use NFPA 101
36" or existing approved hallways which shall be permitted to continue to be used
Industrial Special Purpose = 22"
R-2
1-hr. Fire barrier between R-2 / S-2 *2-hr Fire Barrier between R / S-1 1-hr Fire Barrier between B / R-2 1-hr Fire Barrier between B / S-2
*Per UFC 4-211-01 § 3-3.1.3 Aircraft Hangars (S-1) are required to be separated from areas not directly supporting the hangar with 2-hr Fire Barriers
Fire Dampers are not required at Fire Barriers with a rating of 1-hour or less in buildings equipped with an automatic sprinkler system per IBC Section 717.5.2 Exception 2.
Per § 9-18.1.
Voice Evacuation required by 4-730-10. Mass Notification required by 4-211-01 § 3-6.19.1. Entire building system to be replaced with combination Fire Alarm / Mass Notification per EAFB FD.
32'-0", 1 Story 32'-0", 1 Story 32'-0", 3 Stories
Per UFC 4-211-01 § 3-3.1.1 Aircraft Hangars are limited to non-combustible construction ie. Type I or Type II. The core area is wood framed construction, hence the classification of Type V- B. Per the government, the facility is to remain classified as Fire Station and Aircraft Hangar for this project.
Vertical Openings Per UFC 3-600-01 Use NFPA 101
Special Hazard Protection Per UFC 3-600-01 Use NFPA 101 Section 8.7
Sleeping rooms shall be separated from escape route corridors by smoke partitions
Per § 26.3.5.1 smoke partitions in accordance with § 8.4. Penetrations of smoke partitions shall prohibit the transfer smoke per § 8.4.4.1.
Laundry Rooms shall be separated by smoke partitions
Per UFC 4-730-10 Table 4-28
Interior stairwell shall be unprotected but separated from all spaces on floors 1 & 2 with construction having a minimum 1/2 hour fire resistance rating
Doors into stairwell on floors 1 & 2 to be 20 minute fire doors
Per § 26.2.2.5 Stairways shall be permitted to be unenclosed in accordance with 26.3.1.1.2
Per Table 8.3.3.2.2
Equation 5-3 S-1: Aa = [At + (NS x If)] = 27,000 + (9,000 x 0.75) = 33,750 sf S-2: Aa = [At + (NS x If)] = 40,500 + (13,500 x 0.75) = 50,625 sf R-2: Aa = [At + (NS x If)] = 21,000 + (7,000 x 0.75) = 26,250 sf B: Aa = [At + (NS x If)] = 27,000 + (9,000 x 0.75) = 33,750 sf
506.3.2 Min. Frontage Distance Equation 5-4:
30' Clear Perimeter = 105+303+105+303 = 742 W = [(69x30) +(303x30) +(69x30) +(303x30)] / 742 = 30 ft
506.3.3 Amount of increase Equation 5-5:
[742/742 - 0.25] x 30 / 30 = 0.75
First Floor
S-1 9169/33750=.27 S-2 10596/50625=.21 R-2 1271/26250=.05 B 63/26250=.00
Ratio Sum = .53 < 1 OK
Second Floor
R-2 1049/26250=.04
Ratio Sum = .04 < 1 OK
Third Floor
R-2 1213/26250=.05 B 610/33750=.02
Ratio Sum = .07 < 1 OK
Allowable Area per Story per 508.4.2
Lodging or Rooming - Secondary means of escape is not required when fully sprinklered.
Storage (Ordinary Hazard) - 2 exits required due to common path of travel maximums exceeded - see code plan
Bays 1 and 2 exiting per UFC 4-211-01 not evaluated as part of this project per the government
Handrails
NFPA 101 § 7.2.2.4.1
Within dwelling units handrails shall extend to above the bottom and top risers
Per § 7.2.2.4.5.11
60'-0", 3 StoriesB 32'-0", 3 Stories
B 27,000 SF 33,750
63 SF Group B Occupancy
610 SF Group B Occupancy
Per UFC 3-600-01 § 34-1.2.8 Floor plan reconfigurations that exceed 50% of the floor area require that the entire floor be brought up to the requirements for new construction in UFC 3-600-01 and NFPA 101.
Primary means of escape complying with Chapter 24 Per § 26.2.1.1.1, Per § 24.2.6.1
Per § 40.2.5.3.1
D ate
Project N o.
Architects Engineers
Surveyors 601 C ollege R oad Fairbanks AK 99701
907.452.1241 designalaska.com
AEC
C
Sht.
O f
354th C ivil Engineer Squadron
Eielson AFB, Alaska
Project Engineer
C hief Engineer
D raw n By
D esigned By
R eference
N o.
R ev
D escription
By D ate
22 A U G
FTQ
W
17-1015
R
EN
O
VATE C
O M
BAT ALER
T C
ELL (B1300)
COMM NUMBER: 022103 8/19/2022 3:26:51 PM
AJS
CODE INFORMATION
G
AJS
AKAF AL
TS
TA E O
49 TH
S
ADAM J. SHILLING
No. 140520
REG ISTERED PROFESSIONAL ARCHITE
CT22-08-2022
OCCUPANCY TABULATION NOTES
1.
2.
OCCUPANT LOAD FOR PLUMBING FIXTURES PER
NUMBER OF SLEEPING ROOMS FOR INDIVIDUAL
FIREPERSONS
OCCUPANT LOAD FOR MEANS OF EGRESS PROVIDED
PER NFPA 101 IF NOT OVERRIDDEN BY UFC 3-600-01
SUPPORT / NOTES / CALCULATIONSAPPLICATION / REQUIREMENTCHAPTER REFERENCE
Use ABA Oct. 31, 2008 per UFC 1-200-01 § 2-11UFC 1-200-01, 2-11 Accessibility Building will not comply with ABA.
Use IBC Chp. 12 per
UFC 1-200-01 § 2-12,
UFC 4-730-10 Chp. 3 and Chp. 4.
Rooms containing showers shall be mechanically ventilated in accordance with the International Mechanical Code.
Building will only be occupied by able bodied personnel.
SEE PREVIOUS PAGE FOR PROJECT NAME, AUTHORITY HAVING JURISDICTION, REFERENCED CODES AND STANDARDS
UFC 1-200-01,
2-12 Interior Environment
Use IBC Chp. 29 as modified by UFC 3-420-01 § 4-5.3 and IPC 403.1
UFC 1-200-01 2-29
STC Ratings:
Offices = 39 Day room/Kitchen = 45 Dorm rooms = 55
Occupancy WC - Male WC - Female LAV - M + F Drinking Fountain Service Sink
R
S/Industrial Special Purpose
Provided 4 Unisex 4 Unisex 1 1
Occupancy: 6 M-80% 5 W-20% 1
1:10 = 1 1:10 = 1 1:10 = 2 1:100 = 1 1
Not Normally Occupied
4 Unisex
Showers
1:8 = 2
2 Unisex
Not Normally Occupied
Not Normally Occupied
Not Applicable
Not Normally Occupied
Not Applicable
D ate
Project N o.
Architects Engineers
Surveyors 601 C ollege R oad Fairbanks AK 99701
907.452.1241 designalaska.com
AEC
C
Sht.
O f
354th C ivil Engineer Squadron
Eielson AFB, Alaska
Project Engineer
C hief Engineer
D raw n By
D esigned By
R eference
N o.
R ev
D escription
By D ate
22 A U G
FTQ
W
17-1015
R
EN
O
VATE C
O M
BAT ALER
T C
ELL (B1300)
COMM NUMBER: 022103 8/19/2022 3:26:54 PM
AJS
CODE INFORMATION - OCCUPANCY
G
AJS
OCCUPANCY TABULATION (Per UFC 3-600-01, TABLE10-1 AND NFPA 101) FIRST FLOOR
ROOM AREA (SF)
OCCUPANCY
TYPE
SF PER
PERSON
NUMBER OF
PERSONS
No. NAME
REDUCTION
FACTOR TOTAL
UFC
10-1 NFPA
UFC
10-1 NFPA
100 DAY ROOM 0 666 R-2 0 200 4
101 KITCHEN 0 224 R-2 0 200 2
102 TOILET 0 49 R-2 0 200 1
103 TOILET 0 33 R-2 0 200 1
104 JAN 0 28 R-2 0 200 1
105 OFFICE 0 63 B 0 150 1
106 VESTIBULE 0 50 R-2 0 0
107 PANTRY 0 65 R-2 0 200 1
108 HALL 0 136 R-2 0 0
H103 APPARATUS BAY 3 0 3,185 S-2 200 0 16
H104 APPARATUS BAY 4 0 4,570 S-2 200 0 23
S1 STAIR 0 35 R-2 0 0
U101 FIRE PUMP 0 862 S-2 500 0 2
U102 BOILER TUBE SPACE 0 464 S-2 500 0 1
U103 BOILER 0 700 S-2 500 0 2
U104 GENERATOR 0 611 S-2 500 0 2
11,741 46 11
OCCUPANCY TABULATION (Per UFC 3-600-01, TABLE10-1 AND NFPA 101) SECOND FLOOR
ROOM AREA (SF)
OCCUPANCY
TYPE
SF PER
PERSON
NUMBER OF
PERSONS
No. NAME
REDUCTION
FACTOR TOTAL
UFC
10-1 NFPA
UFC
10-1 NFPA
201 BUNK 0 148 R-2 50 0 3
202 BUNK 0 147 R-2 50 0 3
203 BUNK 0 150 R-2 50 0 3
204 COMMONS 0 281 R-2 0 200 2
205 LAUNDRY 0 23 R-2 0 200 1
206 JAN 0 20 R-2 0 200 1
207 LINEN 0 39 R-2 0 200 1
208 UNISEX BATHROOM 0 94 R-2 0 200 1
S2 STAIR 0 155 R-2 0 0
1,057 9 6
OCCUPANCY TABULATION (Per UFC 3-600-01, TABLE10-1 AND NFPA 101) THIRD FLOOR
ROOM AREA (SF)
OCCUPANCY
TYPE
SF PER
PERSON
NUMBER OF
PERSONS
No. NAME
REDUCTION
FACTOR TOTAL
UFC
10-1 NFPA
UFC
10-1 NFPA
301 BUNK 0 149 R-2 50 0 3
302 BUNK 0 148 R-2 50 0 3
303 BUNK 0 148 R-2 50 0 3
304 COMMONS 0 347 R-2 0 200 2
305 LAUNDRY 0 20 R-2 0 200 1
306 JAN 0 17 R-2 0 200 1
308 UNISEX BATHROOM 0 94 R-2 0 200 1
309 LINEN 0 41 R-2 0 200 1
310 CLOSET 0 28 R-2 0 200 1
311 SERVER 0 110 R-2 300 0 1
312 OFFICE 0 211 B 0 150 2
313 MULTIPURPOSE ROOM 0 399 B 0 200 2
S3 STAIR 0 111 R-2 0 0
1,823 10 11
AKAF AL
TS
TA E O
49 TH
S
ADAM J. SHILLING
No. 140520
REG ISTERED PROFESSIONAL ARCHITE
CT22-08-2022
UP
USE GROUP LEGEND
B
R-2
S-1
S-2
APPARATUS
BAY 4
H104
APPARATUS
BAY 3
H103
HANGAR
BAY 2
H102
HANGAR
BAY 1
H101
FIRE PUMP
U101
BOILER
TUBE SPACE
U102
GENERATOR
U104
A
B
C
D
1 2
3 4
5 6
G111
HANGAR BAY EXITING PER UFC
4-211-01 NOT REQUIRED PER THE
GOVERNMENT AS PART OF THIS
PROJECT
HANGAR BAY EXITING PER UFC
4-211-01 NOT REQUIRED PER THE
GOVERNMENT AS PART OF THIS
PROJECT
BOILER
U103
DAY ROOM
CODE PLAN LEGEND
TRAVEL DISTANCE TO EXIT
FE FIRE EXTINGUISHER; 2A / BC
NON RATED WALLS
SEE G100 FOR CODE INFORMATION
1-HR FIRE BARRIER
SMOKE PARTITION
2-HR FIRE BARRIER
1/2 HR FIRE BARRIER
EXIT
A
B
C
D
1 2 3 4 5 6
COMMON
PATH OF
TRAVEL =
86'-5"
APPARATUS
BAY 4
H104
APPARATUS
BAY 3
H103
HANGAR
BAY 2
H102
HANGAR
BAY 1
H101
FIRE PUMP
U101
BOILER
TUBE SPACE
U102
GENERATOR
U104
PANTRY
OFFICE
DAY ROOM
KITCHEN
G112
MAX. TRAVEL
DISTANCE =
100'-7"
HANGAR BAY EXITING PER UFC
4-211-01 NOT REQUIRED PER THE
GOVERNMENT AS PART OF THIS
PROJECT
HANGAR BAY EXITING PER UFC
4-211-01 NOT REQUIRED PER THE
GOVERNMENT AS PART OF THIS
PROJECT
NOT AN EXIT
NOT AN EXIT
NOT AN EXIT
D ate
Project N o.
Architects Engineers
Surveyors 601 C ollege R oad Fairbanks AK 99701
907.452.1241 designalaska.com
AEC
C
Sht.
O f
354th C ivil Engineer Squadron
Eielson AFB, Alaska
Project Engineer
C hief Engineer
D raw n By
D esigned By
R eference
N o.
R ev
D escription
By D ate
22 A U G
FTQ
W
17-1015
R
EN
O
VATE C
O M
BAT ALER
T C
ELL (B1300)
COMM NUMBER: 022103 8/19/2022 3:26:59 PM
AJS
CODE PLAN - OVERALL
G
AJS
1/16" = 1'-0"G110
1 CODE PLAN - OVERALL - 1ST FLOOR - OCCUPANCY
KEYPLAN
A B
LS LIMITED
SCOPE (LS)
1/16" = 1'-0"G110
2 CODE PLAN - OVERALL - 1ST FLOOR - TRAVEL DISTANCE
AKAF AL
TS
TA E O
49 TH
S
ADAM J. SHILLING
No. 140520
REG ISTERED PROFESSIONAL ARCHITE
CT22-08-2022
USE GROUP LEGEND
B
R-2
S-1
S-2
APPARATUS
BAY 3
H103
HANGAR
BAY 2
H102
FIRE PUMP
U101
BOILER
TUBE SPACE
U102
BOILER
U103
GENERATOR
U104
PANTRY
OFFICE
DAY ROOM
KITCHEN
A
B
C
D
3 4
TOILET
TOILET
103 JAN
STAIR
S1
UP
'-2
A
B
C
D
3 4
UPDN
BUNK
BUNK
BUNK
COMMONS
LINEN
STAIR
S2
UNISEX
BATHROOM
OPEN TO
BELOW
LAUNDRY
JAN
A
B
C
D
3 4
BUNK
BUNK
BUNK
COMMONS
MULTIPURPOSE
ROOM
SERVER
UNISEX
BATHROOM
LAUNDRY
JAN
LINEN
STAIR
S3
DN
CLOSET
OFFICE
NEW ROOF
ACCESS STAIR
NOT AN EXIT
CODE PLAN LEGEND
NON RATED WALLS
SEE G100 FOR CODE INFORMATION
1-HR FIRE BARRIER
SMOKE PARTITION
2-HR FIRE BARRIER
1/2 HR FIRE BARRIER
D ate
Project N o.
Architects Engineers
Surveyors 601 C ollege R oad Fairbanks AK 99701
907.452.1241 designalaska.com
AEC
C
Sht.
O f
354th C ivil Engineer Squadron
Eielson AFB, Alaska
Project Engineer
C hief Engineer
D raw n By
D esigned By
R eference
N o.
R ev
D escription
By D ate
22 A U G
FTQ
W
17-1015
R
EN
O
VATE C
O M
BAT ALER
T C
ELL (B1300)
COMM NUMBER: 022103 8/19/2022 3:27:04 PM
AJS
CODE PLAN - CORE - OCCUPANCY
G
AJS
1/8" = 1'-0"G111
1 CODE PLAN - CORE AREA - 1ST FLOOR - OCCUPANCY
1/8" = 1'-0"G111
2 CODE PLAN - CORE AREA - 2ND FLOOR - OCCUPANCY
1/8" = 1'-0"G111
3 CODE PLAN - CORE AREA - 3RD FLOOR - OCCUPANCY KEYPLAN
A B
LS LIMITED
SCOPE (LS)
KEYPLAN
A B
LS LIMITED
SCOPE (LS)
KEYPLAN
A B
LS LIMITED
SCOPE (LS)
AKAF AL
TS
TA E O
49 TH
S
ADAM J. SHILLING
No. 140520
REG ISTERED PROFESSIONAL ARCHITE
CT22-08-2022
A
B
C
D
3 4
APPARATUS
BAY 3
H103
HANGAR
BAY 2
H102
FIRE PUMP
U101
BOILER
TUBE SPACE
U102
BOILER
U103
GENERATOR
U104
PANTRY
OFFICE
DAY ROOM
KITCHEN
TOILET
TOILET
JAN
STAIR
S1
UP
FE
76'-0"
17'-5"
5ABC
76'-0"
SECOND FLOOR MAX COMMON
PATH OF TRAVEL = 128'
THIRD FLOOR MAX COMMON
PATH OF TRAVEL = 141'
A
B
C
D
3 4
UPDN
FE
BUNK
BUNK
BUNK
COMMONS
LINEN
STAIR
S2
UNISEX
BATHROOM
JAN
LAUNDRY
OPEN TO
BELOW
2A
A
B
C
D
BUNK
BUNK
BUNK
COMMONS
MULTIPURPOSE
ROOM
SERVER
UNISEX
BATHROOM
LAUNDRY
JAN
LINEN
DN
FE 2A
CLOSET
NOT AN EXIT
OFFICE
CODE PLAN LEGEND
SEE G100 FOR CODE INFORMATION
TRAVEL DISTANCE TO EXIT
COMMON PATH OF TRAVEL
FE FIRE EXTINGUISHER
EXIT
D ate
Project N o.
Architects Engineers
Surveyors 601 C ollege R oad Fairbanks AK 99701
907.452.1241 designalaska.com
AEC
C
Sht.
O f
354th C ivil Engineer Squadron
Eielson AFB, Alaska
Project Engineer
C hief Engineer
D raw n By
D esigned By
R eference
N o.
R ev
D escription
By D ate
22 A U G
FTQ
W
17-1015
R
EN
O
VATE C
O M
BAT ALER
T C
ELL (B1300)
COMM NUMBER: 022103 8/19/2022 3:27:08 PM
AJS
CODE PLAN - CORE - TRAVEL DISTANCE
G
AJS
KEYPLAN
A B
LS LIMITED
SCOPE (LS)
KEYPLAN
A B
LS LIMITED
SCOPE (LS)
KEYPLAN
A B
LS LIMITED
SCOPE (LS)
1/8" = 1'-0"G112
1 CODE PLAN - CORE AREA - 1ST FLOOR - TRAVEL DISTANCE
1/8" = 1'-0"G112
2 CODE PLAN - CORE AREA - 2ND FLOOR - TRAVEL DISTANCE
1/8" = 1'-0"G112
3 CODE PLAN - CORE AREA - 3RD FLOOR - TRAVEL DISTANCE
AKAF AL
TS
TA E O
49 TH
S
ADAM J. SHILLING
No. 140520
REG ISTERED PROFESSIONAL ARCHITE
CT22-08-2022
HAZARDOUS MATERIAL NOTES
1. THESE HAZARDOUS MATERIAL NOTES APPLY TO ALL HAZARDOUS MATERIAL SHEETS.
2. A HAZARDOUS MATERIALS ASSESSMENT FOR THE PROPOSED CONSTRUCTION HAS BEEN COMPLETED AS PART OF THIS DESIGN. POTENTIALLY HAZARDOUS MATERIALS IN THE WORK AREA ARE IDENTIFIED ON THESE DRAWINGS. ALL SAMPLE LOCATIONS AND RESULTS COLLECTED AND UTILIZED AS PART OF THIS ASSESSMENT ARE IDENTIFIED ON THE PROJECT DRAWINGS. THE PROJECT DRAWINGS AND SPECIFICATIONS REPRESENT THE ENTIRETY OF THE HAZARDOUS MATERIALS ASSESSMENT FOR THIS PROJECT. A STANDALONE HAZARDOUS MATERIALS ASSESSMENT REPORT IS
NOT AVAILABLE.
3. THE DEMOLITION SCOPE OF WORK FOR EACH DISCIPLINE IS SHOWN IN THE DEMOLITION DRAWINGS FOR EACH DISCIPLINE. ABATEMENT OF HAZARDOUS MATERIALS IS ONLY NECESSARY TO THE EXTENT REQUIRED BY THE SELECTIVE DEMOLITION SCOPE OF WORK.
4. LOCATIONS OF SAMPLES AND MATERIALS SHOWN IN THESE DRAWINGS ARE SCHEMATIC AND APPROXIMATE. ADDITIONAL HAZARDOUS MATERIALS NOT IDENTIFIED IN THESE DRAWINGS MAY BE PRESENT AS HIDDEN HAZARDS. CONTRACTOR MUST IMMEDIATELY NOTIFY OWNER'S REPRESENTATIVE
OF ANY SUSPECTED HIDDEN HAZARD.
5. SAMPLE RESULTS DO NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO PERFORM HIS OWN ASSESSMENT PRIOR TO DEMOLITION TO VERIFY AND QUANTIFY THE PRESENCE OF HAZARDOUS MATERIALS AND POTENTIAL WORKER EXPOSURES.
6. REMOVE AND PROPERLY DISPOSE OF ALL HAZARDOUS MATERIALS RESULTING FROM DEMOLITION OPERATIONS WITHIN THE PROJECT AREA. ALL HAZARDOUS MATERIALS SHALL BE MANIFESTED AND DISPOSED OF IN A LEGAL MANNER, COMPLYING WITH ALL LOCAL, STATE, AND FEDERAL LAWS
AND REGULATIONS.
7. THE CONTRACTOR SHALL PROVIDE RECEIPTS TO THE OWNER'S REPRESENTATIVE INDICATING THE FINAL DISPOSITION OF ALL HAZARDOUS MATERIALS. RECEIPTS FOR ALL HAZARDOUS MATERIALS TRANSPORTED OFF SITE TO A PERMITTED FACILITY FOR DISPOSAL, REMEDIATION, OR TESTING WILL BE TRANSMITTED BY THE CONTRACTOR TO THE OWNER'S REPRESENTATIVE WITHIN 24 HOURS OF DELIVERY TO THE PERMITTED FACILITY. ALL MATERIALS REQUIRING A CHAIN OF CUSTODY WILL REMAIN IN THE CUSTODY OF THE CONTRACTOR UNTIL FINAL DISPOSITION. THE OWNER'S REPRESENTATIVE WILL NOT BE SIGNATORY TO A MANIFEST, CERTIFICATE OF FINAL DISPOSITION OR TRANSFER, OR CHAIN OF CUSTODY
FOR HAZARDOUS MATERIALS SCHEDULED FOR DEMOLITION OR REMOVAL.
PROJECT
LOCATION
LEAD BASED PAINT SAMPLE
(<1mg/cm sq)(HUD)
LEAD BASED PAINT SAMPLE
(>1mg/cm sq)(HUD)
SEE LEAD BASED PAINT TABULATION
RESULTS FOR CONCENTRATION FOR
LEAD SAMPLE NUMBER
ASBESTOS SAMPLE LOCATIONS
NEGATIVE (<1% ASBESTOS)
ASBESTOS SAMPLE LOCATIONS
POSITIVE (>1% ASBESTOS)
SEE ASBESTOS TABULATED RESULTS
FOR ACM SAMPLE NUMBER
LEGEND
ACRONYM KEY
ACM - ASBESTOS CONTAINING MATERIAL
LBP - LEAD BASED PAINT
LF - LINEAR FOOT
ND - NON-DETECT
PC - POINT COUNT
PCB - POLYCHLORINATED BIPHENYL
RACM - REGULATED ASBESTOS CONTAINING MATERIAL
RCRA - RESOURCE CONSERVATION AND RECOVERY ACT
TCLP - TOXICITY CHARACTERISTIC LEACHING PROCEDURE
TSI - THERMAL SYSTEMS INSULATION
STR/CM^2 - STRUCTURES PER SQUARE CENTIMETER
PROJECT
LOCATION
RENOVATE COM
BAT ALERT CELL (B1300)
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
LOCATION M
APS, NOTES, LEGEND, & ACRONYM
KEY
01234
01234
PCB PAINT SAMPLE LOCATIONS
NEGATIVE (NO PCBs DETECTED)
PCB PAINT SAMPLE LOCATIONS
POSITIVE (PCBs DETECTED)
SEE TABULATED RESULTS FOR
SAMPLE NUMBER & RESULTS
H
Peter Beardsley
CE 10934REG IS T ER ED P R O F E S S IO NA L ENGINEER
08/22/2022
NOTE: LIMIT ABATEMENT OF HAZARDOUS MATERIALS TO THE EXTENT NECESSARY TO COMPLETE THE
WORK SPECIFIED ELSEWHERE IN PROJECT DOCUMENTS.
HAZARDOUS MATERIALS QUANTITIES
DESCRIPTION
QUANTITY
1st FLOOR 2nd FLOOR 3rd FLOOR BAYS 3&4
METAL HALIDE BULBS - - - 22
4' MERCURY CONTAINING FLUORESCENT TUBES 36 26 64 -
U-SHAPED BENT MERCURY CONTAINING FLUORESCENT TUBES - 14 - -
MERCURY CONTAINING FLUORESCENT BULBS 1 - 5 -
ASSUMED PCB BALLAST - - - 22
EXIT SIGNS/EMERGENCY LIGHTS WITH LEAD ACID BATTERIES 4 3 5 1
REFRIDGERATOR 2 - 2 -
SMOKE DETECTOR 1 8 - -
ASBESTOS CONTAINING MATERIAL QUANTITIES
ACM CATEGORY DESCRIPTION QUANTITY
FRIABLE NONE IDENTIFIED -
NON-FRIABLE CATEGORY I NONE IDENTIFIED -
NON-FRIABLE CATEGORY II
TRANSITE WALL PANELS GENERATOR ROOM & BOILER ROOM
BLACK ADHESIVE 12 LINEAR FEET
ACM BLACK ADHESIVE
BOILER
TUBE PULL
SPACE
BOILER
ROOM
DE-BRIEF OFFICE
OFFICE
OFFICE
BREAK
COMMONS
MEN WOMEN
C O
R R
ID
O
R
VEST
JANITOR
22212216
A25
A24
A26
A29
A27
A28
STORAGE BAY 2
STORAGE BAY 3
PCB5
PCB6
PCB7
C2-2 C1-2
1/8" = 1'-0"H101
1 EXISTING PLAN - 1ST FLOOR
1st Floor Lead Sample Results
Number Color Surface Substrate Result (mg/cm²) 2205 white door frame metal 0.00 2206 cream door frame fiberglass 0.00 2207 white wall wallpaper 0.00 2208 white ceiling gwb 0.00 2209 cream door frame metal 0.00 2210 cream wall wallpaper 0.00 2211 white wall gwb 0.00 2212 cream wall wallpaper 0.00 2213 cream ceiling gwb 0.00 2214 red floor tile 0.00 2215 beige floor tile 0.01 2216 brown stall metal 0.00 2217 cream corner guard plastic 0.00 2218 brown cove rubber 0.00 2219 cream register cover metal 0.00 2220 cream door frame metal 0.00 2221 black wall wallpaper 0.00 2222 black stair tread rubber 0.00 2223 cream handrail metal 0.01 2224 cream ceiling gwb 0.00
RENOVATE COM
BAT ALERT CELL (B1300)
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
1ST FLOOR ASBESTOS & LEAD SAM
PLE LOCATIONS & RESULTS
LEAD BASED PAINT SAMPLE
(<1mg/cm sq)(HUD)
LEAD BASED PAINT SAMPLE
(>1mg/cm sq)(HUD)
SEE LEAD BASED PAINT TABULATION
RESULTS FOR CONCENTRATION FOR
LEAD SAMPLE NUMBER
ASBESTOS SAMPLE LOCATIONS
NEGATIVE (<1% ASBESTOS)
ASBESTOS SAMPLE LOCATIONS
POSITIVE (>1% ASBESTOS)
SEE ASBESTOS TABULATED RESULTS
FOR ACM SAMPLE NUMBER
LEGEND
01234
01234
PCB PAINT SAMPLE LOCATIONS
NEGATIVE (NO PCBs DETECTED)
PCB PAINT SAMPLE LOCATIONS
POSITIVE (PCBs DETECTED)
SEE TABULATED RESULTS FOR
SAMPLE NUMBER & RESULTS
1st Floor Asbestos Sample Results (Method EPA 600/R-93/116)
Sample ID Description Result A24 gray floor tile ND A24 tan grout ND A24 gray thinset ND A25 white joint compound ND A25 brown/gray gwb ND A26 brown cove ND A26 yellow mastic ND A27 brown/white wall core ND A28 pink floor tile ND A28 white thinset ND A29 white ceiling texture ND C1-2 white joint compound ND C2-2 white caulk ND C3-2 white vinyl tile ND
H
1st Floor PCB by 3546/8082A (mg/kg)
Analyte Sample ID PCB5 PCB6 PCB7
Description tan ceiling paint gray window caulk white wall sealant Aroclor-1016 ND ND ND Aroclor-1221 ND ND ND Aroclor-1232 ND ND ND Aroclor-1242 ND ND ND Aroclor-1248 ND ND ND Aroclor-1254 ND ND ND Aroclor-1260 ND ND ND Aroclor-1262 ND ND ND Aroclor-1268 ND ND ND
Peter Beardsley
CE 10934REG IST ER ED PR O F E S S IO NA L ENGINEER
08/22/2022
BATH
BUNK
JAN
BUNK CONF
BUNK
BUNK
HALL
STAIR
CONTROL
STORAGE BAY 2
STORAGE BAY 3
OPEN TO MECHANICAL
A5
A6
A2
A1 A4
A3
A8
A7
ROOM BELOW
PCB10
C4-2
1/8" = 1'-0"H102
1 EXISTING PLAN - 2ND FLOOR
2nd Floor Lead Sample Results
Number Color Surface Substrate Result (mg/cm²) 2225 off-white door frame metal 0.00 2226 off-white wall wallpaper 0.00 2227 brown stall metal 0.00 2228 cream wall wallpaper 0.00 2229 cream door metal 0.00 2230 white shelf wood 0.00 2231 cream window sill wood 0.00 2232 white ledge joint compound 0.00 2233 white window sill wood 0.00 2234 white wall gwb 0.00 2235 cream wall wallpaper 0.00 2236 cream door metal 0.00 2237 cream door frame metal 0.00 2238 cream handrail metal 0.00 RENOVATE COM
BAT ALERT CELL (B1300)
SU
STAIN
ABLE EN
VIR
O
N M
EN
T
Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
2ND FLOOR ASBESTOS & LEAD SAM
PLE LOCATIONS & RESULTS0123
LEAD BASED PAINT SAMPLE
(<1mg/cm sq)(HUD)
LEAD BASED PAINT SAMPLE
(>1mg/cm sq)(HUD)
SEE LEAD BASED PAINT TABULATION
RESULTS FOR CONCENTRATION FOR
LEAD SAMPLE NUMBER
ASBESTOS SAMPLE LOCATIONS
NEGATIVE (<1% ASBESTOS)
ASBESTOS SAMPLE LOCATIONS
POSITIVE (>1% ASBESTOS)
SEE ASBESTOS TABULATED RESULTS
FOR ACM SAMPLE NUMBER
LEGEND
01234
01234
PCB PAINT SAMPLE LOCATIONS
NEGATIVE (NO PCBs DETECTED)
PCB PAINT SAMPLE LOCATIONS
POSITIVE (PCBs DETECTED)
SEE TABULATED RESULTS FOR
SAMPLE NUMBER & RESULTS
2nd Floor Asbestos Sample Results (Method EPA 600/R-93/116) Sample ID Description Result
A1 white wallpaper ND A2 white joint compound ND A2 brown/white gwb ND A3 carpet ND A3 yellow mastic ND A3 beige adhesive ND A4 carpet ND A4 yellow mastic ND A5 gray/white ceiling tile #1 ND A6 white/yellow ceiling tile #2 ND A7 white joint compound ND A8 yellow mastic ND
C4-2 black mastic ND
H
2nd Floor PCB by 3546/8082A (mg/kg)
Analyte Sample ID PCB10
Description tan wall paint Aroclor-1016 ND Aroclor-1221 ND Aroclor-1232 ND Aroclor-1242 ND Aroclor-1248 ND Aroclor-1254 ND Aroclor-1260 ND Aroclor-1262 ND Aroclor-1268 ND
Peter Beardsley
CE 10934REG IS T ER ED P R O F E S S IO NA L ENG INEER
08/22/2022
KITCHEN
LIVING
PANTRY
CLOS
BATH
STAIR
SERVER
COMMON
LINEN
BUNK BUNK
OPEN TO MECHANICAL
ROOM BELOW
2241 2240
A20
A22
A12
A11
A13
A14
A21
A23
A19
A18
A17
A10
A9
A16
A15
STORAGE BAY 2
STORAGE BAY 3
PCB11
1/8" = 1'-0"H103
1 EXISTING PLAN - 3RD FLOOR
3rd Floor Lead Sample Results
Number Color Surface Substrate Result (mg/cm²) 2239 cream wall wallpaper 0.00 2240 white wall wallpaper 0.00 2241 light gray door frame metal 0.00 2242 cream window frame wood 0.00 2243 off-white wall plywood 0.00 2244 off-white wall gwb 0.00 2245 off-white door metal 0.00 2246 white wall gwb 0.00 2247 white pipe metal 0.00 2248 white door frame metal 0.00 2249 cream exterior siding metal 0.00 2250 cream fire extinguisher cabinet metal 0.00 2251 cream island framing plywood 0.02
RENOVATE COM
BAT ALERT CELL (B1300)
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
3RD FLOOR ASBESTOS & LEAD SAM
PLE LOCATIONS & RESULTS0123
LEAD BASED PAINT SAMPLE
(<1mg/cm sq)(HUD)
LEAD BASED PAINT SAMPLE
(>1mg/cm sq)(HUD)
SEE LEAD BASED PAINT TABULATION
RESULTS FOR CONCENTRATION FOR
LEAD SAMPLE NUMBER
ASBESTOS SAMPLE LOCATIONS
NEGATIVE (<1% ASBESTOS)
ASBESTOS SAMPLE LOCATIONS
POSITIVE (>1% ASBESTOS)
SEE ASBESTOS TABULATED RESULTS
FOR ACM SAMPLE NUMBER
LEGEND
01234
01234
PCB PAINT SAMPLE LOCATIONS
NEGATIVE (NO PCBs DETECTED)
PCB PAINT SAMPLE LOCATIONS
POSITIVE (PCBs DETECTED)
SEE TABULATED RESULTS FOR
SAMPLE NUMBER & RESULTS
3rd Floor Asbestos Sample Results (Method EPA 600/R-93/116)
Sample ID Description Result A9 yellow corner trim mastic ND
A10 beige wallpaper ND A10 white/yellow adhesive ND A11 brown floor tile ND A11 black mastic <0.25% Chrysotile A12 beige cove ND A12 yellow mastic ND A12 white joint compound ND A13 yellow mastic ND A14 carpet ND A14 yellow mastic 0.73% Chrysotile A15 white joint compound ND A16 brown/white wall core ND A17 pink wallpaper ND A17 white/yellow adhesive ND A18 brown cove ND A18 yellow mastic ND A19 brown floor tile ND A19 black adhesive ND A20 white/yellow ceiling tile #2 ND A21 black sink coating ND A22 black stair tread ND A22 red mastic ND A23 brown sheet vinyl ND A23 yellow adhesive ND
H
3rd Floor PCB by 3546/8082A (mg/kg)
Analyte Sample ID PCB11
Description white caulk Aroclor-1016 ND Aroclor-1221 ND Aroclor-1232 ND Aroclor-1242 ND Aroclor-1248 ND Aroclor-1254 ND Aroclor-1260 ND Aroclor-1262 ND Aroclor-1268 ND
Peter Beardsley
CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER
08/22/2022
STORAGE
BAY 3
STORAGE
BAY 4
BOILER
TUBE PULL
SPACE
BOILER
ROOM
DE-BRIEF
COMMONS
MEN WOMEN
VEST
JANITOR
FIRE PUMP
ROOM
22782279
227222712275 2274
A30
A31
A34
A33
A32
B7
B2
B3
B4
B1B5B6
A35
PCB2
PCB1
PCB12
PCB4 ADI
B8
PCB3
1/8" = 1'-0"H104
1 EXISTING PLAN - BAYS 3 & 4
Bays 3 & 4 Asbestos Sample Results (Method EPA 600/R-93/116) Sample ID Description Result
B1 fireproofing ND B2 fireproofing ND B3 fireproofing ND B4 fireproofing ND B5 pink sealant ND B6 black adhesive 7.9% Chrysotile B7 black panel backing ND B8 black apron sealant ND
Bay 3 & 4 Asbestos Sample Results (Method EPA 600/R-93/116) Sample ID Description Result
A30 black cove ND A30 yellow mastic ND A31 brown/white wall ND A32 brown/white gwb ND A32 white joint compound ND A33 tan floor sealant ND A34 duct covering ND A35 tan floor sealant ND A35 gray coating ND
Bay 3 & 4 Lead Sample Results
Number Color Surface Substrate Result (mg/cm²) 2252 red wall metal 0.17 2253 white wall transite 0.00 2254 gray floor epoxy 0.00 2255 yellow ramp concrete 0.00 2256 red cross-brace metal 0.00 2257 tan door metal 0.00 2258 white wall metal 0.00 2260 yellow floor epoxy 0.00 2261 red/brown column metal 6.0 2262 brown column metal 0.08 2263 red back of wall metal 0.11 2264 red front of wall metal 0.16 2265 brown doorway framing metal 2.3 2266 yellow floor epoxy 0.00 2267 yellow floor concrete 0.00 2268 red/brown column metal 7.2 2269 white wall transite 0.00 2270 red door step metal 7.5 2271 brown floor bumper metal 4.4 2272 gray door metal 0.00 2274 dark brown I-beam metal 0.02 2275 yellow original floor striping concrete 2.3 2276 yellow new floor striping epoxy 0.13 2277 white wall fireproofing 0.09 2278 black column metal 4.6 2279 gray column metal 7.8 2280 orange equipment support metal 9.4
LEAD BASED PAINT SAMPLE
(<1mg/cm sq)(HUD)
LEAD BASED PAINT SAMPLE
(>1mg/cm sq)(HUD)
SEE LEAD BASED PAINT TABULATION
RESULTS FOR CONCENTRATION FOR
LEAD SAMPLE NUMBER
ASBESTOS SAMPLE LOCATIONS
NEGATIVE (<1% ASBESTOS)
ASBESTOS SAMPLE LOCATIONS
POSITIVE (>1% ASBESTOS)
SEE ASBESTOS TABULATED RESULTS
FOR ACM SAMPLE NUMBER
LEGEND
RENOVATE COM
BAT ALERT CELL (B1300)
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
BAY 3 & 4 ASBESTOS & LEAD SAM
PLE LOCATIONS & RESULTS
01234
01234
PCB PAINT SAMPLE LOCATIONS
NEGATIVE (NO PCBs DETECTED)
PCB PAINT SAMPLE LOCATIONS
POSITIVE (PCBs DETECTED)
SEE TABULATED RESULTS FOR
SAMPLE NUMBER & RESULTS
Bay 3 & 4 Asbestos Wipe Sample Results (Method
Sample ID Description Result (str/cm²) ADI top of electrical panel <52,000
H
Bays 3 & 4 PCB by 3546/8082A (mg/kg)
Analyte
Sample ID PCB1 PCB2 PCB3 PCB4 PCB12
Description gray floor tar floor sealant red structural steel paint tan exterior paint original yellow floor striping Aroclor-1016 ND ND ND ND ND Aroclor-1221 ND ND ND ND ND Aroclor-1232 ND ND ND ND ND Aroclor-1242 ND ND ND ND ND Aroclor-1248 ND ND ND ND ND Aroclor-1254 ND ND ND ND ND Aroclor-1260 ND ND 0.50 ND ND Aroclor-1262 ND ND ND ND ND Aroclor-1268 ND ND ND ND ND
Peter Beardsley
CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER
08/22/2022
ACM BLACK ADHESIVE
BOILER
TUBE PULL
SPACE
GENERATOR
ROOM
BOILER
ROOM
MEN WOMEN
JANITOR
FIRE PUMP
ROOM
C5
C4
C6 C1
C2
C3
PCB8
PCB9
1/8" = 1'-0"H105
1 EXISTING PLAN - MECHANICAL ROOMS
Mechanical Rooms Asbestos Sample Results (Method EPA 600/R-93/116) Sample ID Description Result
C1 brown/white gwb ND C2 gray Transite 30% Chrysotile C3 white fiberglass sealant ND C4 white fiberglass wrap ND C5 red sealant ND C6 white/silver pipe wrap ND
RENOVATE COM
BAT ALERT CELL (B1300)
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
MECHANICAL ROOMS ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS0123
LEAD BASED PAINT SAMPLE
(<1mg/cm sq)(HUD)
LEAD BASED PAINT SAMPLE
(>1mg/cm sq)(HUD)
SEE LEAD BASED PAINT TABULATION
RESULTS FOR CONCENTRATION FOR
LEAD SAMPLE NUMBER
ASBESTOS SAMPLE LOCATIONS
NEGATIVE (<1% ASBESTOS)
ASBESTOS SAMPLE LOCATIONS
POSITIVE (>1% ASBESTOS)
SEE ASBESTOS TABULATED RESULTS
FOR ACM SAMPLE NUMBER
LEGEND
01234
01234
PCB PAINT SAMPLE LOCATIONS
NEGATIVE (NO PCBs DETECTED)
PCB PAINT SAMPLE LOCATIONS
POSITIVE (PCBs DETECTED)
SEE TABULATED RESULTS FOR
SAMPLE NUMBER & RESULTS
Mechanical Rooms Lead Sample Results
Number Color Surface Substrate Result (mg/cm²) 2281 gray wall transite 0.03 2282 white wall gwb 0.00 2284 red door wood 1.2 2285 gray door wood 2.4 2286 dark green floor cement 2.0 2287 salmon floor cement 2.0 2288 brown wall transite 0.05 2289 black column metal 10.1 3111 tan wall gwb 15.3 3112 white wall gwb 13.9 3113 tan floor cement 15.5
H
Mechanical Rooms PCB by 3546/8082A (mg/kg)
Analyte Sample ID 8 9
Description tan & green floor paint dark yellow floor sealant Aroclor-1016 ND ND Aroclor-1221 ND ND Aroclor-1232 ND ND Aroclor-1242 ND ND Aroclor-1248 ND ND Aroclor-1254 ND ND Aroclor-1260 2.6 ND Aroclor-1262 ND ND Aroclor-1268 ND ND
Peter Beardsley
CE 10934REG IS T ER ED P R O F E S S IO NA L ENG INEER
08/22/2022
NOTE: TRANSITE PANELS IDENTIFIED IN GENERATOR ROOM AND BOILER ROOM. KNOWN
TRANSITE WALLS ARE LABELED WITH WARNING ADHESIVE "DANGER-ASBESTOS" STICKERS.
RENOVATE COM
BAT ALERT CELL (B1300)
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
LABORATORY REPORTS
H
Peter Beardsley
CE 10934REGIS T ER E D P R O FE S S IO NA L ENGINEER
08/22/2022
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
LABORATORY REPORTS
H
Peter Beardsley
CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER
08/22/2022
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
LABORATORY REPORTS
H
Peter Beardsley
CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER
08/22/2022
SU
STAIN
ABLE EN
VIR
O N
M
EN
T Juneau: 5438 Shaune D rive
907.452.5688 Anchorage: 3105 Lakeshore D
rive
EN
ER
G Y, H
EALTH
& SAFETY
Fairbanks: 2400 C ollege R oad
C orporate N o.: AEC C
LABORATORY REPORTS
H
Peter Beardsley
CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER
08/22/2022
SUMP
EXISTING BOLLARD, TYP.
EXISTING FIRE HYDRANT
EXISTING ASPHALT
BUILDING 1300
EXTERNAL STAIRS TO ROOF
PROPOSED BOLLARDS
TYP. OF 10
S511
EXISTING LANDING
TO REMAIN
CONCRETE LANDING
1, 2
C700
CONCRETE LANDING
1, 2
C700
PROPOSED BOLLARDS
S511
PROPOSED BOLLARDS
CENTERED ON EDGE
OF DOORWAY
S511
2'-0"
2'-0"
5' -0
7'-0" 1'-6"
10" EACH SIDE
6"
SITE PLAN1
C200 1" = 10'
Jay A. Baxter
No. CE12976 19-Aug-2022
1' -0
1'
-0
6" BOLLARD, TYP. 3
S511
5' -0
5'-0"
CONCRETE LANDING PLAN VIEW1
C700 NOT TO SCALE
6"
ALIGN RELATIVE TO THE
HINGE SIDE OF THE JAMB
WIDTH PER PLANS
#4 REBAR AT 12" O.C. EACH WAY
EXISTING GRADE
FRONT PROFILE
IN SITU
SOIL
LANDING ELEVATION TO
MATCH INTERIOR FINISH
FLOOR ELEVATION
TOP OF
EXISTING
GRADE
CONNECTION TO DOORWAY
1/2" DEEP SEALANT W/
1/4" RAD AT SURFACE
SLOPE @ 2% (TYP.)
EXISTING WOOD
PLATFORM ON TOP
OF EXISTING APRON
LANDING ABOVE EXISTING GRADE2
C700 NOT TO SCALE
FELT
6" APPROX.
Jay A. Baxter
No. CE12976 19-Aug-2022
IN SITU SOIL
CONCRETE
EARTH
GYPSUM
RIGID INSULATION
MASONRY CONCRETE
PLYWOOD
MATERIAL LEGEND
BATT INSULATION
SPRAY FOAM INSULATION
EXISTING
CONSTRUCTION
NO ARCHITECTURAL WORK
THIS AREA
BATT INSULATION
EXISTING
CONSTRUCTION DETAIL
ARCHITECTURAL SYMBOL LEGEND
150 SF
Room Name
DETAIL NAME
DETAIL NUMBER
SHEET LOCATION
DETAIL SCALE
TRUE NORTH
GRID LINE
ROOM NAME
ROOM NUMBER
PLAN NORTH
DETAIL NUMBER
SHEET LOCATION
SIMILAR
REVISION
SPOT ELEVATION
SEE OTHER DISCIPLINES FOR ADDITIONAL SYMBOLS
KEYED NOTE
DOOR TAG
A100
A100
EXTERIOR ELEVATION
SHEET LOCATION
DETAIL NUMBER
INTERIOR ELEVATION
SHEET LOCATION
DETAIL NUMBER
DETAIL NUMBER 4
A
BUILDING SECTION
DETAIL NUMBER
SHEET LOCATION
SIMILAR
WALL SECTION
WINDOW TYPE
ROOM AREA
1/8" = 1'-0"A101 View Name
1/4" / 1'-0"
.SPOT SLOPE
101ROOM NUMBER
A101
SIM
A101
SIM
101A
1. SEE OTHER DISCIPLINES FOR ADDITIONAL ABBREVIATIONS.
2. SEE GENERAL SHEETS FOR CODE ABBREVIATIONS.
3. SEE ASSEMBLY TYPES FOR HYPHENATED ASSEMBLY TAGS
(I.E. C-A1, W01-3A, AND WX-3A).
4. SEE MATERIAL SCHEDULE FOR HYPHENATED MATERIAL TAGS
(I.E. ACT-1, CPT-1, AND RB-1).
5. SEE ROOM AND DOOR SCHEDULE FOR SPECIFIC RELEVANT
ABBREVIATIONS.
6. SOME ABBREVIATIONS LISTED BELOW MAY NOT BE USED IN
THIS PROJECT.
(E) EXISTING
ADA AMERICAN DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
ELEC ELECTRICAL
FV FIELD VERIFY
GA GYPSUM ASSOCIATION
GYP GYPSUM BOARD
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
ITSP INSULATED TRANSLUCENT SANDWICH PANEL
MAX MAXIMUM
MECH MECHANICAL
MFSD MANUFACTURER'S STANDARD
MIN MINIMUM
NIC NOT IN CONTRACT
OC ON CENTER
OD OVERFLOW DRAIN
OFOI OWNER FURNISHED OWNER INSTALLED
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OSB ORIENTED STRAND BOARD
OTS OPEN TO STRUCTURE
PLY PLYWOOD
RD ROOF DRAIN
SIP STRUCTURAL INSULATED PANEL
SPEC SPECIFICATION
STC SOUND TRANSMISSION CLASS
STRUC STRUCTURAL
TBD TO BE DETERMINED
TYP TYPICAL
UL UNDERWRITERS LABORATORY
VTR VENT THROUGH ROOF
ARCHITECTURAL STANDARD ABBREVIATIONS
ARCHITECTURAL PROJECT SPECIFIC ABBREVIATIONS
NA NOT APPLICABLE
WX-A1
WALL ASSEMBLY CATEGORY - FUNCTION
WALL BUILDING ENVELOPE DESIGNATION
WALL ASSEMBLY MODIFIER
WALL ASSEMBLY CATEGORY - FUNCTION
PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.
WF WALL - FOUNDATION
WP WALL - PARAPET
WR WALL - RETAINING
WX WALL - EXTERIOR
WALL BUILDING ENVELOPE DESIGNATION
A EIFS / FOUNDATION
B RAINSCREEN
C IMP
D OTHER
WALL ASSEMBLY MODIFIER
NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY TYPES.
THE BELOW ARE COMMONLY USED EXAMPLES. SEE
ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.
1 TYPICAL
EXTERIOR ASSEMBLY TAG LEGEND - WALL
R-A1
ROOF ASSEMBLY CATEGORY - FUNCTION
ROOF ASSEMBLY MODIFIER
ROOF ASSEMBLY CATEGORY - FUNCTION
R ROOF
RS ROOF - SOFFIT
ROOF BUILDING ENVELOPE DESIGNATION
A EIFS / EPDM / FOUNDATION
B RAINSCREEN / ATTIC
C IMP
D OTHER
ROOF ASSEMBLY MODIFIER
NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.
SEE ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.
1 TYPICAL
EXTERIOR ASSEMBLY TAG LEGEND - ROOF
ROOF BUILDING ENVELOPE DESIGNATION
W01-3A
WALL ASSEMBLY CATEGORY - FUNCTION
WALL SHEATHING DESIGNATION
WALL FRAMING MEMBER SIZE
WALL ASSEMBLY MODIFIER
WALL ASSEMBLY CATEGORY - FUNCTION
PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.
W WALL - INTERIOR
WALL SHEATHING DESIGNATION
ASSEMBLIES MAY NOT INCLUDE A SHEATHING DESIGNATION.
THE SHEATHING DESIGNATION REFERS TO THE NUMBER OF
SHEATHING LAYERS ON EACH SIDE OF THE FRAMING MEMBER.
00 FIRST SIDE (0 LAYERS) + SECOND SIDE (0 LAYERS)
01 FIRST SIDE (0 LAYERS) + SECOND SIDE (1 LAYERS)
02 FIRST SIDE (0 LAYERS) + SECOND SIDE (2 LAYERS)
03 FIRST SIDE (0 LAYERS) + SECOND SIDE (3 LAYERS)
04 FIRST SIDE (0 LAYERS) + SECOND SIDE (4 LAYERS)
11 FIRST SIDE (1 LAYERS) + SECOND SIDE (1 LAYERS)
12 FIRST SIDE (1 LAYERS) + SECOND SIDE (2 LAYERS)
13 FIRST SIDE (1 LAYERS) + SECOND SIDE (3 LAYERS)
14 FIRST SIDE (1 LAYERS) + SECOND SIDE (4 LAYERS)
22 FIRST SIDE (2 LAYERS) + SECOND SIDE (2 LAYERS)
23 FIRST SIDE (2 LAYERS) + SECOND SIDE (3 LAYERS)
24 FIRST SIDE (2 LAYERS) + SECOND SIDE (4 LAYERS)
33 FIRST SIDE (3 LAYERS) + SECOND SIDE (3 LAYERS)
34 FIRST SIDE (3 LAYERS) + SECOND SIDE (4 LAYERS)
44 FIRST SIDE (4 LAYERS) + SECOND SIDE (4 LAYERS)
INTERIOR ASSEMBLY TAG LEGEND - WALL
BUILDING ENVELOPE LEGEND
SEE EXTERIOR ASSEMBLY TYPES, EXTERIOR DETAILS,
MATERIAL SCHEDULE, AND SPECIFICATIONS FOR
ADDITIONAL INFORMATION. PROJECTS MAY NOT INCLUDE
ALL BUILDING ENVELOPE CATEGORIES.
DIRECTION
OF DRYING
BE-1 OR 2: FOUNDATION MEMBRANE
BE-4: INTERIOR AIR/VAPOR BARRIER
BE-5 OR 6: EXTERIOR AIR/WATER BARRIER
BE-7,8, OR 9: ROOF UNDERLAY
BUILDING ENVELOPE COMPONENT
BUILDING ENVELOPE METAL FLASHING
DESCRIBES THE DIRECTION OF AIRFLOW IN A
VENTED OR VENTILATED ASSEMBLY
DESCRIBES THE DIRECTION AN ASSEMBLY
WILL DRY. PERMEABLE MATERIALS REQUIRED
TO DRY AS SHOWN
C-A1
CEILING ASSEMBLY CATEGORY
CEILING ASSEMBLY MODIFIER
CEILING ASSEMBLY CATEGORY
PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.
C CEILING
CEILING MATERIAL DESIGNATION
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF
ASSEMBLY TYPES. THE BELOW ARE COMMONLY USED
EXAMPLES. SEE ASSEMBLY TYPES FOR ADDITIONAL
DESIGNATIONS.
A ACOUSTIC CEILING TILE
G GYPSUM BOARD
S SPECIALTY MATERIAL
CEILING ASSEMBLY MODIFIER
NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.
SEE ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.
1 TYPICAL
INTERIOR ASSEMBLY TAG LEGEND - CEILING
CEILING MATERIAL DESIGNATION
F-W1
FLOOR ASSEMBLY CATEGORY - FUNCTION
FLOOR ASSEMBLY MODIFIER
FLOOR ASSEMBLY CATEGORY - FUNCTION
FLOORS ON GRADE OR THOSE COMPRISING THE EXTERIOR
ENVELOPE OF THE BUILDING ARE CONSIDERED EXTERIOR.
PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.
F FLOOR - INTERIOR
FLOOR MATERIAL DESIGNATION
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF
ASSEMBLY TYPES. THE BELOW ARE COMMONLY USED
EXAMPLES. SEE ASSEMBLY TYPES FOR ADDITIONAL
DESIGNATIONS.
W WOOD
FLOOR ASSEMBLY MODIFIER
NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.
SEE ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.
1 TYPICAL
2 FIRE RATED
INTERIOR ASSEMBLY TAG LEGEND - FLOOR
FLOOR MATERIAL DESIGNATION
WALL FRAMING MEMBER SIZE
FURRING AND METAL STUDS
0 7/8" FURRING CHANNELS
1 1 5/8" METAL STUDS
2 2 1/2" METAL STUDS
3 3 5/8" METAL STUDS
4 4" METAL STUDS
6 6" METAL STUDS
8 8" METAL STUDS
SHAFT WALLS
2 2 1/2" METAL CH STUDS
4 4" METAL CH STUDS
6 6" METAL CH STUDS
WOOD STUDS
4 2x4 WOOD STUDS 6 2x6 WOOD STUDS 8 2x8 WOOD STUDS
CMU
2 1 5/8" CMU
4 3 5/8" CMU
6 5 5/8" CMU
8 7 5/8" CMU
10 9 5/8" CMU
12 11 5/8" CMU
CONCRETE
# CONCRETE THICKNESS
WALL ASSEMBLY MODIFIER
LETTERS A THRU Z REPRESENT DESCRIPTIONS OF ASSEMBLY
TYPES. THE BELOW ARE COMMONLY USED EXAMPLES. SEE
ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.
- TYPICAL
A ACOUSTIC
F FIRE RATED
G FIRE AND SOUND RATED
H FIRE AND SOUND RATED - SEE ASSEMBLY TYPES
K TILE
L TILE AND SOUND RATED
P PLYWOOD
S SOUND RATED
W WOOD STUD
X WOOD STUD, FIRE RATED
Y WOOD STUD, FIRE AND SOUND RATED
Z WOOD STUD, SOUND RATED
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
ARCHITECTURAL NOTES DESCRIBE WORK COMPRISING
THE ENTIRE ARCHITECTURAL DISCIPLINE.
SHEET NOTES DESCRIBE WORK COMPRISING THE ENTIRE
SHEET ON WHICH THE NOTES APPEAR INCLUDING
SHEETS ON WHICH THE NOTES ARE REFERENCED.
CONSTRUCTION DOCUMENTS ARE PREPARED FOR THE
PURPOSES OF COMMUNICATING DESIGN INTENT.
DRAWINGS ARE GRAPHIC REPRESENTATIONS CONVEYING
THE QUANTITATIVE EXTENT AND RELATIONSHIP BETWEEN
PROJECT ELEMENTS.
SPECIFICATIONS ARE WRITTEN REPRESENTATIONS
CONVEYING THE QUALITATIVE REQUIREMENTS OF
PROJECT ELEMENTS.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A
COMPLETE AND FINISHED PRODUCT FULFILLING THE
INTENT OF THE CONSTRUCTION DOCUMENTS.
THE TERM 'NEW' MAY BE USED TO DISTINGUISH NEW
FROM EXISTING IN SOME INSTANCES. OMISSION OF THE
TERM 'NEW' IS NOT NECESSARILY AN INDICATION THAT
THE ELEMENT IS EXISTING.
THE TERM 'ALL' MAY BE USED TO CLARIFY SCOPE.
OMISSION OF THE TERM 'ALL' IS NOT NECESSARILY AN
INDICATION THAT THE SCOPE IS LIMITED.
SEE GENERAL CODE INFORMATION AND CODE PLAN.
PROVIDE CONSTRUCTION IN COMPLIANCE WITH OSHA.
COORDINATE ARCHITECTURAL WORK WITH CIVIL,
HAZARDOUS MATERIALS, STRUCTURAL, MECHANICAL,
FIRE PROTECTION, ELECTRICAL, AND OTHER DISCIPLINES.
SEE STRUCTURAL FOR SPECIFIC INFORMATION
REGARDING LOAD BEARING MEMBERS, MECHANICAL
FASTENERS, MASTIC ADHESION, AND STRUCTURE.
FURNITURE IS SHOWN FOR COORDINATION PURPOSES
ONLY. FURNITURE IS GOVERNMENT FURNISHED AND
GOVERNMENT INSTALLED UNLESS NOTED OTHERWISE.
PATCH, REPAIR, AND REFINISH EXISTING SURFACES TO
REMAIN, AFFECTED BY WORK.
FIELD VERIFY DIMENSIONS SHOWN TO EXISTING
CONSTRUCTION PRIOR TO WORK. NOTIFY ARCHITECT
WHERE DISCREPANCIES ARE DISCOVERED.
DIMENSIONS AT EXISTING CONSTRUCTION ARE
MEASURED FROM FACE OF EXISTING FINISH UNLESS
NOTED OTHERWISE.
DIMENSIONS AT NEW CONSTRUCTION ARE MEASURED
FROM FACE OF FRAMING UNLESS NOTED OTHERWISE.
CONFIRM DIMENSIONS INDICATED WITH 'FIELD VERIFY'
AND/ OR 'FV' PRIOR TO WORK.
DIMENSIONS INDICATED AS 'CLEAR' REQUIRE MINIMUM
CLEARANCE MEASURED TO FINISHED FACES, UNLESS
NOTED OTHERWISE.
DIMENSIONS INDICATED WITH '+/-' BRING THE
CONTRACTORS ATTENTION TO AREAS WITH FLEXIBILITY
GREATER THAN ADJACENT AREAS NOT OTHERWISE
INDICATED.
SEE SPECIFICATIONS FOR ALLOWABLE TOLERANCES.
CONFIRM MANUFACTURERS INSTRUCTIONS CONFORM TO
SPECIFIED TOLERANCES.
SEE DETAILS FOR DIMENSION AND LEVEL REFERENCE
POINTS.
ARCHITECTURAL…