This document provides details on a federal contract solicitation from the Department of the Air Force Pacific Air Forces. Solicitation number FA500422B0013 seeks proposals for the renovation of the Combat Alert Cell (CAC) in Building 1300. Offerors must submit proposals by October 14, 2022. The work includes renovating and upgrading the CAC to improve mission capabilities. It will replace or repair existing systems as needed. The contract is set aside for small businesses only. The solicitation and five attachments include the statement of work, evaluation criteria, and other requirements for the renovation project. Proposals are due by October 14th, with contract award anticipated by November 2022. The renovation work must be completed within 180 calendar days of the award date.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 View Name 1/8" = 1'-0"A101

Room name

GENERAL SYMBOLS

NAME

NUMBER

SHEET LOCATION

SCALE

TRUE NORTH

GRID LINE

ROOM NAME

ROOM NUMBER

PLAN NORTH

REVISION

SEE DISCIPLINES FOR SPECIFIC SYMBOLS

PROJECT TEAM

OWNER

354TH CIVIL ENGINEER SQUADRON

2310 CENTRAL AVENUE, BUILDING 2258

EIELSON AIR FORCE BASE, AK 99702

DESIGNER

DESIGN ALASKA

601 COLLEGE ROAD

FAIRBANKS, AK 99701

VICINITY MAP

PROJECT

LOCATION

BUILDING

R

ICH

ARD

SO

N

H

IG

H W

AY

MAIN ENTRY GATE

ALASKA MAP

PACIFIC OCEAN

ARCTIC OCEAN

BERING

SEA

KODIAK

ARCTIC CIRCLE

SEWARD

SITKA

JUNEAU

HAINES

WHITEHORSE YT

DAWSON YT

HAINES

JCT

HOMER

ANCHORAGE

EAGLE

CORDOVA

VALDEZ

GLENNALLEN

EIELSON

AFB

NENANA

TANANA CIRCLE

NOME

KOTZEBUE

UTQIAGVIK

(BARROW)

PRUDHOE BAY

U N

IT

ED

S

TA

TE

S

R U

SS

IA

U N

ITED

STATES

C

AN

AD

A

PROJECT

LOCATION

D ate

Project N o.

Architects Engineers

Surveyors 601 C ollege R oad Fairbanks AK 99701

907.452.1241 designalaska.com

AEC

C

Sht.

O f

354th C ivil Engineer Squadron

Eielson AFB, Alaska

Project Engineer

C hief Engineer

D raw n By

D esigned By

R eference

N o.

R ev

D escription

By D ate

22 A U G

FTQ

W

17-1015

R

EN

O

VATE C

O M

BAT ALER

T C

ELL (B1300)

COMM NUMBER: 022103 8/22/2022 3:40:18 PM

AJS

GENERAL INFORMATION

G

AJS

RENOVATE COMBAT ALERT CELL (B1300)

EIELSON AFB, ALASKA

354TH CIVIL ENGINEER SQUADRON

ARCHITECTURAL

A301 EXTERIOR ELEVATION - EAST AND SOUTH

A400 SECTION - BUILDING

A410 SECTION - WALL

A470 VERTICAL CIRCULATION - SECTIONS

A471 VERTICAL CIRCULATION - SECTIONS

A480 VERTICAL CIRCULATION - DETAILS

A500 EXTERIOR DETAILS - ASSEMBLY TYPE

A510 EXTERIOR DETAILS - TYPICAL

A551 EXTERIOR DETAILS - OPEN - DOOR

A552 EXTERIOR DETAILS - OPEN - WINDOW

A553 EXTERIOR DETAILS - OPEN - LOUVER

A554 EXTERIOR DETAILS - OPEN - SNOW HOOD

A555 EXTERIOR DETAILS - OPEN - O/H DOOR

A560 EXTERIOR DTL - WALL-ROOF TRANSITION

A580 EXTERIOR DETAIL - ROOF

A600 INTERIOR PLAN - ENLARGED

A610 INTERIOR PLAN - ACOUSTIC - CORE AREA

A622 INTERIOR PLAN - CEILING - CORE AREA

A631 INTERIOR PLAN - FINISH - STORAGE BAY

A632 INTERIOR PLAN - FINISH - SIGNAGE - CORE

A700 INTERIOR ELEVATION - ACCESSORY TYPE

A710 INTERIOR ELEVATION

A711 INTERIOR ELEVATION

A800 INTERIOR DETAILS - ASSEMBLY TYPE

A810 INTERIOR DETAILS

A811 INTERIOR DETAILS

A812 INTERIOR DETAILS

A813 INTERIOR DETAILS

A900 SCHEDULE AND TYPE - ROOM

A910 SCHEDULE AND TYPE - MATERIAL

A920 SCHEDULE AND TYPE - DOOR - WINDOW

A940 SCHEDULE AND TYPE - SIGNAGE

ARCHITECTURAL

A001 ARCHITECTURAL INFORMATION

A100 EXISTING PLAN - OVERALL

A111 DEMOLITION PLAN - STORAGE BAY

A112 DEMOLITION PLAN - CORE AREA

A121 DEMOLITION ROOF PLAN - APPARATUS

A122 DEMOLITION ROOF PLAN - CORE/ BAY

A211 RENOVATION PLAN - APPARATUS BAY

A212 RENOVATION PLAN - CORE AREA

A221 RENOVATION ROOF PLAN - APPARATUS

A222 RENOVATION ROOF PLAN - CORE/ BAY

A300 EXTERIOR ELEVATION - WEST AND NORTH

GENERAL

G001 GENERAL INFORMATION

G100 CODE INFORMATION

G101 CODE INFORMATION - OCCUPANCY

G110 CODE PLAN - OVERALL

G111 CODE PLAN - CORE - OCCUPANCY

G112 CODE PLAN - CORE - TRAVEL DISTANCE

G300 ELECTRICAL AREA CLASSIFICATION PLAN

STRUCTURAL

S001 STRUCTURAL GENERAL NOTES

S002 SPECIAL INSPECTIONS

S003 SPECIAL INSPECTIONS

S100 DEMOLITION PLAN - CORE AREA

S200 RENOVATION PLAN - CORE AREA

S210 RENOVATION PLAN - STORAGE BAYS

S211 RENOVATION PLAN - BAY 2

S400 HRV PLATFORM PLAN & DETAILS

S401 HRV PLATFORM DETAILS

S410 EXTERIOR STAIR STRUCTURAL PLAN

S411 EXTERIOR STAIR DETAILS

S500 OVERHEAD DOOR FRAMING

S501 CROSS BRACE REPAIRS

S510 WOOD, CFS, AND CONCRETE DETAILS

S511 WOOD, CFS, AND CONCRETE DETAILS

MECHANICAL

M303 REFRIGERANT PIPING PLANS

M310 HYDRONIC DIAGRAMS AND DETAILS

M401 PLUMBING PLANS

M402 1ST FLOOR PARTIAL PLUMBING PLAN

M404 UNDERFLOOR PLUMBING PLANS

M410 PLUMBING RISER DIAGRAMS AND DETAILS

MECHANICAL

M001 ABBREVIATIONS & LEGENDS

M002 MECHANICAL EQUIPMENT SCHEDULE

M003 MECHANICAL SCHEDULES

M101 VENTILATION DEMOLITION PLANS

M102 VENTILATION DEMOLITION ELEVATIONS

M103 HYDRONIC DEMOLITION PLANS

M104 PLUMBING DEMOLITION PLANS

M105 HEATING PLANT DEMOLITION DIAGRAM

M201 VENTILATION PLANS

M202 APPARATUS BAYS VENTILATION PLAN

M220 VENTILATION ELEVATIONS

M230 VENTILATION ELEVATIONS & DETAILS

M231 MECHANICAL DETAILS

M301 HYDRONIC PLANS

M302 ENLARGED BAY 3&4 HYDRONIC PLAN

ELECTRICAL

E001 LEGENDS SCHEDULES AND DETAILS

E002 POWER RISERS AND CALCULATIONS

E003 ADDITIONAL DETAILS

E101 LIGHTING DEMO PLANS

E102 POWER/SIGNAL DEMO PLANS

E200 LIGHTING PLANS

E300 POWER/SIGNAL PLANS

E500 PANEL SCHEDULES

E501 PANEL SCHEDULES

E502 PANEL SCHEDULES

E600 FIREFIGHTER ALERT SYSTEM PLANS

HAZARDOUS MATERIALS

H100 LOCATION MAPS, NOTES, LEGENDS, & ACRONYM KEY

H101 1ST FLOOR ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS

H102 2ND FLOOR ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS

H103 3RD FLOOR ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS

H104 BAY 3 & 4 ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS

H105 MECHANICAL ROOMS ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS

H106 LABORATORY REPORTS

H107 LABORATORY REPORTS

H108 LABORATORY REPORTS

H109 LABORATORY REPORTS

FIRE PROTECTION

F001 CODE COMPLIANCE SITE PLAN

F100 FIRE ALARM NOTES, LEGENDS, SYMBOLS

F101 FIRE ALARM DEMO OVERALL PLAN

F102 FIRE ALARM DEMO ENLARGED PLANS

F103 FIRE ALARM RENO OVERALL PLAN

F104 FIRE ALARM RENO ENLARGED PLANS

F200 FIRE SUPP. NOTES, LEGENDS, SYMBOLS

F201 FIRE SUPP. DEMO OVERALL PLAN

F202 FIRE SUPP. DEMO ENLARGED PLANS

F203 FIRE SUPP. RENO OVERALL PLAN

F204 FIRE SUPP. RENO ENLARGED PLANS

FTQW 17-1015

CIVIL

C200 SITE PLAN

C700 CIVIL DETAILS

CODE INFORMATION

SUPPORT / NOTES / CALCULATIONSAPPLICATION / REQUIREMENT

R-2 Residential S-2 Storage (Parking) S-1 Aircraft Hangar B Business

Use IBC Chapter 5

Building Height Limitations Section 504 Table 504.3 & 504.4 Section 508.4.3

Building Area Modifications IBC Section 506.2

PROJECT NAME:

AUTHORITY HAVING

JURISDICTION (AHJ):

GOVERNING CODES:

Fire-Resistance Rating for Exterior Walls Based on Fire Separation Distance IBC Table 602

Fire separation distance

Type VB - Separated Mixed Use - Fully Sprinklered

OCC ALLOWABLE ACTUAL

R-2

OCC ALLOWABLE

21,000 SF 26,250

Secondary means of escape per § 26.2.1.2 in accordance with § 24.2.2.. Per § 24.2.2.1.2(2) secondary means of escape is not required when fully sprinklered.

Building Area Limitations Section 506 Table 506.2

23,954 SF

Primary structural frame Interior bearing walls Exterior bearing walls Nonbearing walls and partitions *unless required by NFPA 101, see fire and smoke protection features below* Floor construction and secondary members

Roof construction and secondary members

Type VBBUILDING ELEMENT

TypeOccupancy Required rating

S-1, S-2, R-2, B X > 30 VB 0

See Occupancy Tabulation on Code Information - Occupancy Plan

IBC: Actual Floor Area by Occupancy First Floor

Second Floor

Third Floor

Total:

60'-0", 3 Stories

1,271 SF Group R-2 Occupancy

1,057 SF Group R-2 Occupancy

Group S-1 Occupancy

10,596 SF

Group R-2 Occupancy 1,213 SF

Building shall be fully sprinklered

Lodging or Rooming - Not required.

Industrial Special Purpose - Not required.

Storage (Ordinary Hazard) - Not required.

S-2 40,500 SF

60'-0", 2 StoriesS-1

50,625

Group

ALLOWABLE WITH

INCREASES

SUPPORT / NOTES / CALCULATIONSAPPLICATION / REQUIREMENT

Occ. Load UFC 3-600-01 Table 10-1 / NFPA 101

Minimum Egress Width

NFPA 101 § 7.3.4

Use UFC 3-600-01, 9-7

Dead End Corridor NFPA 101 - Chps. 26, 40, 42, and UFC 4-211-01

Max Travel Distance NFPA 101 - Chps. 26, 40, 42, and UFC 4-211-01

CHAPTER

UFC 1-200-01 2-3

Use and Occupancy Classification

UFC 1-200-01 2-4

Special Detailed Requirements Based on Use and Occupancy

UFC 1-200-01 2-5

General Building Heights and Areas

UFC 1-200-01 2-6

Types of Construction

Use IBC Chapter 3 and NFPA 101 via UFC 3-600-01

Use IBC Chapter 6 and UFC 3-600-01

Fire-Resistance Rating for Building Elements IBC Table 601

CHAPTER

UFC 1-200-01 2-8

Interior Finishes

Use UFC 3-600-01 and UFC 3-120-10

NFPA 101 Chp. 26, 40, 42 and Table A.10.2.2

UFC 1-200-01 2-9

Fire Protection Systems

Fire Extinguishers UFC

3-600-01, 9-17, NFPA

101, NFPA 10

Number of Exits

NFPA 101 § 7.4.1.1

UFC 1-200-01 2-10

Means of Egress

Use UFC 3-600-01

REFERENCE

REFERENCE

UFC 4-211-01 applies for Hangar Bays 1 & 2 per § 4-4.1 UFC 4-730-10 not addressed in UFC 3-600-01 however per SOW UFC applies to the greatest extent possible

Separated Mixed Use Building.

*Per NFPA 101 § 6.1.14.1.3 New Business is incidental to Lodging and Rooming House and areas shall be permitted to be considered part of the predominant (Lodging and Rooming House) occupancy and subject to the provisions that apply to the predominant occupancy.

Allowable Area Increase due to Frontage per 506.3

RENOVATE COMBAT ALERT CELL (B1300)

PACIFIC AIR FORCES (PACAF)

UFC 1-200-01 General Building Requirements (Change 1, 8 October 2019) UFC 3-600-01 Fire Protection Engineering for Facilities (Change 6, 6 May 2021) UFC 4-211-01 Aircraft Maintenance Hangars (Change 3, April 20, 2021) UFC 4-730-10 Fire Stations (Change 1, June 11, 2021) 2018 International Building Code (IBC), (as amended by UFC 1-200-01) 2021 NFPA 101- Life Safety Code 2019 Installation for Sprinkler Systems (NFPA) 13

CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE

PORTIONS OF THE GOVERNING CODES INCLUDING

REFERENCED CODES AND STANDARDS.

NOTE: PREVIOUS/ORIGINAL CODE ANALYSIS WAS

NOT PROVIDED FOR THIS RENOVATION. EXISTING

BUILDING INFORMATION FOR THIS ANALYSIS IS

DETERMINED FROM SITE OBSERVATION AND OWNER

PROVIDED INFORMATION / DRAWINGS.

NOTE: 'SECTION' IS REPLACED WITH

THE CHARACTER '§' THIS SHEET.

Fire Separation Distance Degree of Protection Allowable Area

30' or greater Unprotected, Sprinklered

Maximum Area of Exterior Wall Openings IBC Table 705.8 No Limit / Not Required No limit

UFC 1-200-01 2-7

Fire and Smoke Protection Features

IBC NFPA

Lodging or Rooming Houses Storage Ordinary Hazard Industrial Special Purpose New Business*

Lodging or Rooming Chp. 26, 10.2 Floor Class

Storage Chp. 42 Floor Class

Exits Exit Access Corridors Walls and Ceilings

Other Spaces

A, B, or C Minimum critical radiant flux of at least 0.1 W/cm2

A, B, or C A, B, or C Minimum critical radiant flux of at least

0.1 W/cm2

A or B I or II

A, B, or C I or II

A, B, or C

NA

Lodging § 26.2

Storage § 42.2.6

Not Required

400 ft.

Lodging § 26.2

Storage § 42.2.5

Not Required

100 ft.

Common Path of Travel NFPA 101 - Chps. 26, 40, 42, and UFC 4-211-01

Lodging § 26.2

Storage § 42.2.5

Not Required

100 ft.

Fire Alarm per UFC 3-600-01 and NFPA 101 / Mass Notification per UFC 4-010-01

Fire alarm required

Per § 9-7.2.1.2 Core area wet pipe system to be replaced. Remainder of building suppression system to remain as existing.

Group I and II Aircraft Hangar Roofs shall be FM Class 1 Roof Assembly per NFPA 409 § 7.6.2 and UFGS 07 54 19 § 1.3.1 a.

all PVC Roofing.

A, B, or C

Interior Walls / Ceilings

A, B, or C

Emergency Lighting NFPA 101 Chp. 7.8

Lodging Rooms per Chp. 7.8 Chp. 42 - Occupied Spaces only.

Provided at exit access and exits.

60'-0", 3 StoriesS-2

S-1 27,000 SF 33,750

Group S-2 Occupancy

9,169 SF

Industrial Special Purpose Chp. 40 Floor Class

A or B

I or II

A, B, or C

I or II

A, B, or C

NA

A, B, or C

Not required, but being provided in kitchen and laundry rooms per EAFB FD.

Industrial Special Purpose § 40.2.6.1

400 ft.

Hangars 150 ft. per

UFC 4-211-01

Bays 1 and 2 exiting per UFC 4-211-01 not evaluated as part of this project per the government

Industrial Special Purpose § 40.2.5.1

50 ft.

Industrial Special Purpose § 40.2.5.1

100 ft.

Occupancy Separations Per UFC 3-600-01 Use IBC Chapter 5

Interior Non- Load Bearing Partitions (Excluding Occupancy Separations) Per UFC 3-600-01 Use NFPA 101

36" or existing approved hallways which shall be permitted to continue to be used

Industrial Special Purpose = 22"

R-2

1-hr. Fire barrier between R-2 / S-2 *2-hr Fire Barrier between R / S-1 1-hr Fire Barrier between B / R-2 1-hr Fire Barrier between B / S-2

*Per UFC 4-211-01 § 3-3.1.3 Aircraft Hangars (S-1) are required to be separated from areas not directly supporting the hangar with 2-hr Fire Barriers

Fire Dampers are not required at Fire Barriers with a rating of 1-hour or less in buildings equipped with an automatic sprinkler system per IBC Section 717.5.2 Exception 2.

Per § 9-18.1.

Voice Evacuation required by 4-730-10. Mass Notification required by 4-211-01 § 3-6.19.1. Entire building system to be replaced with combination Fire Alarm / Mass Notification per EAFB FD.

32'-0", 1 Story 32'-0", 1 Story 32'-0", 3 Stories

Per UFC 4-211-01 § 3-3.1.1 Aircraft Hangars are limited to non-combustible construction ie. Type I or Type II. The core area is wood framed construction, hence the classification of Type V- B. Per the government, the facility is to remain classified as Fire Station and Aircraft Hangar for this project.

Vertical Openings Per UFC 3-600-01 Use NFPA 101

Special Hazard Protection Per UFC 3-600-01 Use NFPA 101 Section 8.7

Sleeping rooms shall be separated from escape route corridors by smoke partitions

Per § 26.3.5.1 smoke partitions in accordance with § 8.4. Penetrations of smoke partitions shall prohibit the transfer smoke per § 8.4.4.1.

Laundry Rooms shall be separated by smoke partitions

Per UFC 4-730-10 Table 4-28

Interior stairwell shall be unprotected but separated from all spaces on floors 1 & 2 with construction having a minimum 1/2 hour fire resistance rating

Doors into stairwell on floors 1 & 2 to be 20 minute fire doors

Per § 26.2.2.5 Stairways shall be permitted to be unenclosed in accordance with 26.3.1.1.2

Per Table 8.3.3.2.2

Equation 5-3 S-1: Aa = [At + (NS x If)] = 27,000 + (9,000 x 0.75) = 33,750 sf S-2: Aa = [At + (NS x If)] = 40,500 + (13,500 x 0.75) = 50,625 sf R-2: Aa = [At + (NS x If)] = 21,000 + (7,000 x 0.75) = 26,250 sf B: Aa = [At + (NS x If)] = 27,000 + (9,000 x 0.75) = 33,750 sf

506.3.2 Min. Frontage Distance Equation 5-4:

30' Clear Perimeter = 105+303+105+303 = 742 W = [(69x30) +(303x30) +(69x30) +(303x30)] / 742 = 30 ft

506.3.3 Amount of increase Equation 5-5:

[742/742 - 0.25] x 30 / 30 = 0.75

First Floor

S-1 9169/33750=.27 S-2 10596/50625=.21 R-2 1271/26250=.05 B 63/26250=.00

Ratio Sum = .53 < 1 OK

Second Floor

R-2 1049/26250=.04

Ratio Sum = .04 < 1 OK

Third Floor

R-2 1213/26250=.05 B 610/33750=.02

Ratio Sum = .07 < 1 OK

Allowable Area per Story per 508.4.2

Lodging or Rooming - Secondary means of escape is not required when fully sprinklered.

Storage (Ordinary Hazard) - 2 exits required due to common path of travel maximums exceeded - see code plan

Bays 1 and 2 exiting per UFC 4-211-01 not evaluated as part of this project per the government

Handrails

NFPA 101 § 7.2.2.4.1

Within dwelling units handrails shall extend to above the bottom and top risers

Per § 7.2.2.4.5.11

60'-0", 3 StoriesB 32'-0", 3 Stories

B 27,000 SF 33,750

63 SF Group B Occupancy

610 SF Group B Occupancy

Per UFC 3-600-01 § 34-1.2.8 Floor plan reconfigurations that exceed 50% of the floor area require that the entire floor be brought up to the requirements for new construction in UFC 3-600-01 and NFPA 101.

Primary means of escape complying with Chapter 24 Per § 26.2.1.1.1, Per § 24.2.6.1

Per § 40.2.5.3.1

D ate

Project N o.

Architects Engineers

Surveyors 601 C ollege R oad Fairbanks AK 99701

907.452.1241 designalaska.com

AEC

C

Sht.

O f

354th C ivil Engineer Squadron

Eielson AFB, Alaska

Project Engineer

C hief Engineer

D raw n By

D esigned By

R eference

N o.

R ev

D escription

By D ate

22 A U G

FTQ

W

17-1015

R

EN

O

VATE C

O M

BAT ALER

T C

ELL (B1300)

COMM NUMBER: 022103 8/19/2022 3:26:51 PM

AJS

CODE INFORMATION

G

AJS

AKAF AL

TS

TA E O

49 TH

S

ADAM J. SHILLING

No. 140520

REG ISTERED PROFESSIONAL ARCHITE

CT22-08-2022

OCCUPANCY TABULATION NOTES

1.

2.

OCCUPANT LOAD FOR PLUMBING FIXTURES PER

NUMBER OF SLEEPING ROOMS FOR INDIVIDUAL

FIREPERSONS

OCCUPANT LOAD FOR MEANS OF EGRESS PROVIDED

PER NFPA 101 IF NOT OVERRIDDEN BY UFC 3-600-01

SUPPORT / NOTES / CALCULATIONSAPPLICATION / REQUIREMENTCHAPTER REFERENCE

Use ABA Oct. 31, 2008 per UFC 1-200-01 § 2-11UFC 1-200-01, 2-11 Accessibility Building will not comply with ABA.

Use IBC Chp. 12 per

UFC 1-200-01 § 2-12,

UFC 4-730-10 Chp. 3 and Chp. 4.

Rooms containing showers shall be mechanically ventilated in accordance with the International Mechanical Code.

Building will only be occupied by able bodied personnel.

SEE PREVIOUS PAGE FOR PROJECT NAME, AUTHORITY HAVING JURISDICTION, REFERENCED CODES AND STANDARDS

UFC 1-200-01,

2-12 Interior Environment

Use IBC Chp. 29 as modified by UFC 3-420-01 § 4-5.3 and IPC 403.1

UFC 1-200-01 2-29

STC Ratings:

Offices = 39 Day room/Kitchen = 45 Dorm rooms = 55

Occupancy WC - Male WC - Female LAV - M + F Drinking Fountain Service Sink

R

S/Industrial Special Purpose

Provided 4 Unisex 4 Unisex 1 1

Occupancy: 6 M-80% 5 W-20% 1

1:10 = 1 1:10 = 1 1:10 = 2 1:100 = 1 1

Not Normally Occupied

4 Unisex

Showers

1:8 = 2

2 Unisex

Not Normally Occupied

Not Normally Occupied

Not Applicable

Not Normally Occupied

Not Applicable

D ate

Project N o.

Architects Engineers

Surveyors 601 C ollege R oad Fairbanks AK 99701

907.452.1241 designalaska.com

AEC

C

Sht.

O f

354th C ivil Engineer Squadron

Eielson AFB, Alaska

Project Engineer

C hief Engineer

D raw n By

D esigned By

R eference

N o.

R ev

D escription

By D ate

22 A U G

FTQ

W

17-1015

R

EN

O

VATE C

O M

BAT ALER

T C

ELL (B1300)

COMM NUMBER: 022103 8/19/2022 3:26:54 PM

AJS

CODE INFORMATION - OCCUPANCY

G

AJS

OCCUPANCY TABULATION (Per UFC 3-600-01, TABLE10-1 AND NFPA 101) FIRST FLOOR

ROOM AREA (SF)

OCCUPANCY

TYPE

SF PER

PERSON

NUMBER OF

PERSONS

No. NAME

REDUCTION

FACTOR TOTAL

UFC

10-1 NFPA

UFC

10-1 NFPA

100 DAY ROOM 0 666 R-2 0 200 4

101 KITCHEN 0 224 R-2 0 200 2

102 TOILET 0 49 R-2 0 200 1

103 TOILET 0 33 R-2 0 200 1

104 JAN 0 28 R-2 0 200 1

105 OFFICE 0 63 B 0 150 1

106 VESTIBULE 0 50 R-2 0 0

107 PANTRY 0 65 R-2 0 200 1

108 HALL 0 136 R-2 0 0

H103 APPARATUS BAY 3 0 3,185 S-2 200 0 16

H104 APPARATUS BAY 4 0 4,570 S-2 200 0 23

S1 STAIR 0 35 R-2 0 0

U101 FIRE PUMP 0 862 S-2 500 0 2

U102 BOILER TUBE SPACE 0 464 S-2 500 0 1

U103 BOILER 0 700 S-2 500 0 2

U104 GENERATOR 0 611 S-2 500 0 2

11,741 46 11

OCCUPANCY TABULATION (Per UFC 3-600-01, TABLE10-1 AND NFPA 101) SECOND FLOOR

ROOM AREA (SF)

OCCUPANCY

TYPE

SF PER

PERSON

NUMBER OF

PERSONS

No. NAME

REDUCTION

FACTOR TOTAL

UFC

10-1 NFPA

UFC

10-1 NFPA

201 BUNK 0 148 R-2 50 0 3

202 BUNK 0 147 R-2 50 0 3

203 BUNK 0 150 R-2 50 0 3

204 COMMONS 0 281 R-2 0 200 2

205 LAUNDRY 0 23 R-2 0 200 1

206 JAN 0 20 R-2 0 200 1

207 LINEN 0 39 R-2 0 200 1

208 UNISEX BATHROOM 0 94 R-2 0 200 1

S2 STAIR 0 155 R-2 0 0

1,057 9 6

OCCUPANCY TABULATION (Per UFC 3-600-01, TABLE10-1 AND NFPA 101) THIRD FLOOR

ROOM AREA (SF)

OCCUPANCY

TYPE

SF PER

PERSON

NUMBER OF

PERSONS

No. NAME

REDUCTION

FACTOR TOTAL

UFC

10-1 NFPA

UFC

10-1 NFPA

301 BUNK 0 149 R-2 50 0 3

302 BUNK 0 148 R-2 50 0 3

303 BUNK 0 148 R-2 50 0 3

304 COMMONS 0 347 R-2 0 200 2

305 LAUNDRY 0 20 R-2 0 200 1

306 JAN 0 17 R-2 0 200 1

308 UNISEX BATHROOM 0 94 R-2 0 200 1

309 LINEN 0 41 R-2 0 200 1

310 CLOSET 0 28 R-2 0 200 1

311 SERVER 0 110 R-2 300 0 1

312 OFFICE 0 211 B 0 150 2

313 MULTIPURPOSE ROOM 0 399 B 0 200 2

S3 STAIR 0 111 R-2 0 0

1,823 10 11

AKAF AL

TS

TA E O

49 TH

S

ADAM J. SHILLING

No. 140520

REG ISTERED PROFESSIONAL ARCHITE

CT22-08-2022

UP

USE GROUP LEGEND

B

R-2

S-1

S-2

APPARATUS

BAY 4

H104

APPARATUS

BAY 3

H103

HANGAR

BAY 2

H102

HANGAR

BAY 1

H101

FIRE PUMP

U101

BOILER

TUBE SPACE

U102

GENERATOR

U104

A

B

C

D

1 2

3 4

5 6

G111

HANGAR BAY EXITING PER UFC

4-211-01 NOT REQUIRED PER THE

GOVERNMENT AS PART OF THIS

PROJECT

HANGAR BAY EXITING PER UFC

4-211-01 NOT REQUIRED PER THE

GOVERNMENT AS PART OF THIS

PROJECT

BOILER

U103

DAY ROOM

CODE PLAN LEGEND

TRAVEL DISTANCE TO EXIT

FE FIRE EXTINGUISHER; 2A / BC

NON RATED WALLS

SEE G100 FOR CODE INFORMATION

1-HR FIRE BARRIER

SMOKE PARTITION

2-HR FIRE BARRIER

1/2 HR FIRE BARRIER

EXIT

A

B

C

D

1 2 3 4 5 6

COMMON

PATH OF

TRAVEL =

86'-5"

APPARATUS

BAY 4

H104

APPARATUS

BAY 3

H103

HANGAR

BAY 2

H102

HANGAR

BAY 1

H101

FIRE PUMP

U101

BOILER

TUBE SPACE

U102

GENERATOR

U104

PANTRY

OFFICE

DAY ROOM

KITCHEN

G112

MAX. TRAVEL

DISTANCE =

100'-7"

HANGAR BAY EXITING PER UFC

4-211-01 NOT REQUIRED PER THE

GOVERNMENT AS PART OF THIS

PROJECT

HANGAR BAY EXITING PER UFC

4-211-01 NOT REQUIRED PER THE

GOVERNMENT AS PART OF THIS

PROJECT

NOT AN EXIT

NOT AN EXIT

NOT AN EXIT

D ate

Project N o.

Architects Engineers

Surveyors 601 C ollege R oad Fairbanks AK 99701

907.452.1241 designalaska.com

AEC

C

Sht.

O f

354th C ivil Engineer Squadron

Eielson AFB, Alaska

Project Engineer

C hief Engineer

D raw n By

D esigned By

R eference

N o.

R ev

D escription

By D ate

22 A U G

FTQ

W

17-1015

R

EN

O

VATE C

O M

BAT ALER

T C

ELL (B1300)

COMM NUMBER: 022103 8/19/2022 3:26:59 PM

AJS

CODE PLAN - OVERALL

G

AJS

1/16" = 1'-0"G110

1 CODE PLAN - OVERALL - 1ST FLOOR - OCCUPANCY

KEYPLAN

A B

LS LIMITED

SCOPE (LS)

1/16" = 1'-0"G110

2 CODE PLAN - OVERALL - 1ST FLOOR - TRAVEL DISTANCE

AKAF AL

TS

TA E O

49 TH

S

ADAM J. SHILLING

No. 140520

REG ISTERED PROFESSIONAL ARCHITE

CT22-08-2022

USE GROUP LEGEND

B

R-2

S-1

S-2

APPARATUS

BAY 3

H103

HANGAR

BAY 2

H102

FIRE PUMP

U101

BOILER

TUBE SPACE

U102

BOILER

U103

GENERATOR

U104

PANTRY

OFFICE

DAY ROOM

KITCHEN

A

B

C

D

3 4

TOILET

TOILET

103 JAN

STAIR

S1

UP

'-2

A

B

C

D

3 4

UPDN

BUNK

BUNK

BUNK

COMMONS

LINEN

STAIR

S2

UNISEX

BATHROOM

OPEN TO

BELOW

LAUNDRY

JAN

A

B

C

D

3 4

BUNK

BUNK

BUNK

COMMONS

MULTIPURPOSE

ROOM

SERVER

UNISEX

BATHROOM

LAUNDRY

JAN

LINEN

STAIR

S3

DN

CLOSET

OFFICE

NEW ROOF

ACCESS STAIR

NOT AN EXIT

CODE PLAN LEGEND

NON RATED WALLS

SEE G100 FOR CODE INFORMATION

1-HR FIRE BARRIER

SMOKE PARTITION

2-HR FIRE BARRIER

1/2 HR FIRE BARRIER

D ate

Project N o.

Architects Engineers

Surveyors 601 C ollege R oad Fairbanks AK 99701

907.452.1241 designalaska.com

AEC

C

Sht.

O f

354th C ivil Engineer Squadron

Eielson AFB, Alaska

Project Engineer

C hief Engineer

D raw n By

D esigned By

R eference

N o.

R ev

D escription

By D ate

22 A U G

FTQ

W

17-1015

R

EN

O

VATE C

O M

BAT ALER

T C

ELL (B1300)

COMM NUMBER: 022103 8/19/2022 3:27:04 PM

AJS

CODE PLAN - CORE - OCCUPANCY

G

AJS

1/8" = 1'-0"G111

1 CODE PLAN - CORE AREA - 1ST FLOOR - OCCUPANCY

1/8" = 1'-0"G111

2 CODE PLAN - CORE AREA - 2ND FLOOR - OCCUPANCY

1/8" = 1'-0"G111

3 CODE PLAN - CORE AREA - 3RD FLOOR - OCCUPANCY KEYPLAN

A B

LS LIMITED

SCOPE (LS)

KEYPLAN

A B

LS LIMITED

SCOPE (LS)

KEYPLAN

A B

LS LIMITED

SCOPE (LS)

AKAF AL

TS

TA E O

49 TH

S

ADAM J. SHILLING

No. 140520

REG ISTERED PROFESSIONAL ARCHITE

CT22-08-2022

A

B

C

D

3 4

APPARATUS

BAY 3

H103

HANGAR

BAY 2

H102

FIRE PUMP

U101

BOILER

TUBE SPACE

U102

BOILER

U103

GENERATOR

U104

PANTRY

OFFICE

DAY ROOM

KITCHEN

TOILET

TOILET

JAN

STAIR

S1

UP

FE

76'-0"

17'-5"

5ABC

76'-0"

SECOND FLOOR MAX COMMON

PATH OF TRAVEL = 128'

THIRD FLOOR MAX COMMON

PATH OF TRAVEL = 141'

A

B

C

D

3 4

UPDN

FE

BUNK

BUNK

BUNK

COMMONS

LINEN

STAIR

S2

UNISEX

BATHROOM

JAN

LAUNDRY

OPEN TO

BELOW

2A

A

B

C

D

BUNK

BUNK

BUNK

COMMONS

MULTIPURPOSE

ROOM

SERVER

UNISEX

BATHROOM

LAUNDRY

JAN

LINEN

DN

FE 2A

CLOSET

NOT AN EXIT

OFFICE

CODE PLAN LEGEND

SEE G100 FOR CODE INFORMATION

TRAVEL DISTANCE TO EXIT

COMMON PATH OF TRAVEL

FE FIRE EXTINGUISHER

EXIT

D ate

Project N o.

Architects Engineers

Surveyors 601 C ollege R oad Fairbanks AK 99701

907.452.1241 designalaska.com

AEC

C

Sht.

O f

354th C ivil Engineer Squadron

Eielson AFB, Alaska

Project Engineer

C hief Engineer

D raw n By

D esigned By

R eference

N o.

R ev

D escription

By D ate

22 A U G

FTQ

W

17-1015

R

EN

O

VATE C

O M

BAT ALER

T C

ELL (B1300)

COMM NUMBER: 022103 8/19/2022 3:27:08 PM

AJS

CODE PLAN - CORE - TRAVEL DISTANCE

G

AJS

KEYPLAN

A B

LS LIMITED

SCOPE (LS)

KEYPLAN

A B

LS LIMITED

SCOPE (LS)

KEYPLAN

A B

LS LIMITED

SCOPE (LS)

1/8" = 1'-0"G112

1 CODE PLAN - CORE AREA - 1ST FLOOR - TRAVEL DISTANCE

1/8" = 1'-0"G112

2 CODE PLAN - CORE AREA - 2ND FLOOR - TRAVEL DISTANCE

1/8" = 1'-0"G112

3 CODE PLAN - CORE AREA - 3RD FLOOR - TRAVEL DISTANCE

AKAF AL

TS

TA E O

49 TH

S

ADAM J. SHILLING

No. 140520

REG ISTERED PROFESSIONAL ARCHITE

CT22-08-2022

HAZARDOUS MATERIAL NOTES

1. THESE HAZARDOUS MATERIAL NOTES APPLY TO ALL HAZARDOUS MATERIAL SHEETS.

2. A HAZARDOUS MATERIALS ASSESSMENT FOR THE PROPOSED CONSTRUCTION HAS BEEN COMPLETED AS PART OF THIS DESIGN. POTENTIALLY HAZARDOUS MATERIALS IN THE WORK AREA ARE IDENTIFIED ON THESE DRAWINGS. ALL SAMPLE LOCATIONS AND RESULTS COLLECTED AND UTILIZED AS PART OF THIS ASSESSMENT ARE IDENTIFIED ON THE PROJECT DRAWINGS. THE PROJECT DRAWINGS AND SPECIFICATIONS REPRESENT THE ENTIRETY OF THE HAZARDOUS MATERIALS ASSESSMENT FOR THIS PROJECT. A STANDALONE HAZARDOUS MATERIALS ASSESSMENT REPORT IS

NOT AVAILABLE.

3. THE DEMOLITION SCOPE OF WORK FOR EACH DISCIPLINE IS SHOWN IN THE DEMOLITION DRAWINGS FOR EACH DISCIPLINE. ABATEMENT OF HAZARDOUS MATERIALS IS ONLY NECESSARY TO THE EXTENT REQUIRED BY THE SELECTIVE DEMOLITION SCOPE OF WORK.

4. LOCATIONS OF SAMPLES AND MATERIALS SHOWN IN THESE DRAWINGS ARE SCHEMATIC AND APPROXIMATE. ADDITIONAL HAZARDOUS MATERIALS NOT IDENTIFIED IN THESE DRAWINGS MAY BE PRESENT AS HIDDEN HAZARDS. CONTRACTOR MUST IMMEDIATELY NOTIFY OWNER'S REPRESENTATIVE

OF ANY SUSPECTED HIDDEN HAZARD.

5. SAMPLE RESULTS DO NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO PERFORM HIS OWN ASSESSMENT PRIOR TO DEMOLITION TO VERIFY AND QUANTIFY THE PRESENCE OF HAZARDOUS MATERIALS AND POTENTIAL WORKER EXPOSURES.

6. REMOVE AND PROPERLY DISPOSE OF ALL HAZARDOUS MATERIALS RESULTING FROM DEMOLITION OPERATIONS WITHIN THE PROJECT AREA. ALL HAZARDOUS MATERIALS SHALL BE MANIFESTED AND DISPOSED OF IN A LEGAL MANNER, COMPLYING WITH ALL LOCAL, STATE, AND FEDERAL LAWS

AND REGULATIONS.

7. THE CONTRACTOR SHALL PROVIDE RECEIPTS TO THE OWNER'S REPRESENTATIVE INDICATING THE FINAL DISPOSITION OF ALL HAZARDOUS MATERIALS. RECEIPTS FOR ALL HAZARDOUS MATERIALS TRANSPORTED OFF SITE TO A PERMITTED FACILITY FOR DISPOSAL, REMEDIATION, OR TESTING WILL BE TRANSMITTED BY THE CONTRACTOR TO THE OWNER'S REPRESENTATIVE WITHIN 24 HOURS OF DELIVERY TO THE PERMITTED FACILITY. ALL MATERIALS REQUIRING A CHAIN OF CUSTODY WILL REMAIN IN THE CUSTODY OF THE CONTRACTOR UNTIL FINAL DISPOSITION. THE OWNER'S REPRESENTATIVE WILL NOT BE SIGNATORY TO A MANIFEST, CERTIFICATE OF FINAL DISPOSITION OR TRANSFER, OR CHAIN OF CUSTODY

FOR HAZARDOUS MATERIALS SCHEDULED FOR DEMOLITION OR REMOVAL.

PROJECT

LOCATION

LEAD BASED PAINT SAMPLE

(<1mg/cm sq)(HUD)

LEAD BASED PAINT SAMPLE

(>1mg/cm sq)(HUD)

SEE LEAD BASED PAINT TABULATION

RESULTS FOR CONCENTRATION FOR

LEAD SAMPLE NUMBER

ASBESTOS SAMPLE LOCATIONS

NEGATIVE (<1% ASBESTOS)

ASBESTOS SAMPLE LOCATIONS

POSITIVE (>1% ASBESTOS)

SEE ASBESTOS TABULATED RESULTS

FOR ACM SAMPLE NUMBER

LEGEND

ACRONYM KEY

ACM - ASBESTOS CONTAINING MATERIAL

LBP - LEAD BASED PAINT

LF - LINEAR FOOT

ND - NON-DETECT

PC - POINT COUNT

PCB - POLYCHLORINATED BIPHENYL

RACM - REGULATED ASBESTOS CONTAINING MATERIAL

RCRA - RESOURCE CONSERVATION AND RECOVERY ACT

TCLP - TOXICITY CHARACTERISTIC LEACHING PROCEDURE

TSI - THERMAL SYSTEMS INSULATION

STR/CM^2 - STRUCTURES PER SQUARE CENTIMETER

PROJECT

LOCATION

RENOVATE COM

BAT ALERT CELL (B1300)

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

LOCATION M

APS, NOTES, LEGEND, & ACRONYM

KEY

01234

01234

PCB PAINT SAMPLE LOCATIONS

NEGATIVE (NO PCBs DETECTED)

PCB PAINT SAMPLE LOCATIONS

POSITIVE (PCBs DETECTED)

SEE TABULATED RESULTS FOR

SAMPLE NUMBER & RESULTS

H

Peter Beardsley

CE 10934REG IS T ER ED P R O F E S S IO NA L ENGINEER

08/22/2022

NOTE: LIMIT ABATEMENT OF HAZARDOUS MATERIALS TO THE EXTENT NECESSARY TO COMPLETE THE

WORK SPECIFIED ELSEWHERE IN PROJECT DOCUMENTS.

HAZARDOUS MATERIALS QUANTITIES

DESCRIPTION

QUANTITY

1st FLOOR 2nd FLOOR 3rd FLOOR BAYS 3&4

METAL HALIDE BULBS - - - 22

4' MERCURY CONTAINING FLUORESCENT TUBES 36 26 64 -

U-SHAPED BENT MERCURY CONTAINING FLUORESCENT TUBES - 14 - -

MERCURY CONTAINING FLUORESCENT BULBS 1 - 5 -

ASSUMED PCB BALLAST - - - 22

EXIT SIGNS/EMERGENCY LIGHTS WITH LEAD ACID BATTERIES 4 3 5 1

REFRIDGERATOR 2 - 2 -

SMOKE DETECTOR 1 8 - -

ASBESTOS CONTAINING MATERIAL QUANTITIES

ACM CATEGORY DESCRIPTION QUANTITY

FRIABLE NONE IDENTIFIED -

NON-FRIABLE CATEGORY I NONE IDENTIFIED -

NON-FRIABLE CATEGORY II

TRANSITE WALL PANELS GENERATOR ROOM & BOILER ROOM

BLACK ADHESIVE 12 LINEAR FEET

ACM BLACK ADHESIVE

BOILER

TUBE PULL

SPACE

BOILER

ROOM

DE-BRIEF OFFICE

OFFICE

OFFICE

BREAK

COMMONS

MEN WOMEN

C O

R R

ID

O

R

VEST

JANITOR

22212216

A25

A24

A26

A29

A27

A28

STORAGE BAY 2

STORAGE BAY 3

PCB5

PCB6

PCB7

C2-2 C1-2

1/8" = 1'-0"H101

1 EXISTING PLAN - 1ST FLOOR

1st Floor Lead Sample Results

Number Color Surface Substrate Result (mg/cm²) 2205 white door frame metal 0.00 2206 cream door frame fiberglass 0.00 2207 white wall wallpaper 0.00 2208 white ceiling gwb 0.00 2209 cream door frame metal 0.00 2210 cream wall wallpaper 0.00 2211 white wall gwb 0.00 2212 cream wall wallpaper 0.00 2213 cream ceiling gwb 0.00 2214 red floor tile 0.00 2215 beige floor tile 0.01 2216 brown stall metal 0.00 2217 cream corner guard plastic 0.00 2218 brown cove rubber 0.00 2219 cream register cover metal 0.00 2220 cream door frame metal 0.00 2221 black wall wallpaper 0.00 2222 black stair tread rubber 0.00 2223 cream handrail metal 0.01 2224 cream ceiling gwb 0.00

RENOVATE COM

BAT ALERT CELL (B1300)

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

1ST FLOOR ASBESTOS & LEAD SAM

PLE LOCATIONS & RESULTS

LEAD BASED PAINT SAMPLE

(<1mg/cm sq)(HUD)

LEAD BASED PAINT SAMPLE

(>1mg/cm sq)(HUD)

SEE LEAD BASED PAINT TABULATION

RESULTS FOR CONCENTRATION FOR

LEAD SAMPLE NUMBER

ASBESTOS SAMPLE LOCATIONS

NEGATIVE (<1% ASBESTOS)

ASBESTOS SAMPLE LOCATIONS

POSITIVE (>1% ASBESTOS)

SEE ASBESTOS TABULATED RESULTS

FOR ACM SAMPLE NUMBER

LEGEND

01234

01234

PCB PAINT SAMPLE LOCATIONS

NEGATIVE (NO PCBs DETECTED)

PCB PAINT SAMPLE LOCATIONS

POSITIVE (PCBs DETECTED)

SEE TABULATED RESULTS FOR

SAMPLE NUMBER & RESULTS

1st Floor Asbestos Sample Results (Method EPA 600/R-93/116)

Sample ID Description Result A24 gray floor tile ND A24 tan grout ND A24 gray thinset ND A25 white joint compound ND A25 brown/gray gwb ND A26 brown cove ND A26 yellow mastic ND A27 brown/white wall core ND A28 pink floor tile ND A28 white thinset ND A29 white ceiling texture ND C1-2 white joint compound ND C2-2 white caulk ND C3-2 white vinyl tile ND

H

1st Floor PCB by 3546/8082A (mg/kg)

Analyte Sample ID PCB5 PCB6 PCB7

Description tan ceiling paint gray window caulk white wall sealant Aroclor-1016 ND ND ND Aroclor-1221 ND ND ND Aroclor-1232 ND ND ND Aroclor-1242 ND ND ND Aroclor-1248 ND ND ND Aroclor-1254 ND ND ND Aroclor-1260 ND ND ND Aroclor-1262 ND ND ND Aroclor-1268 ND ND ND

Peter Beardsley

CE 10934REG IST ER ED PR O F E S S IO NA L ENGINEER

08/22/2022

BATH

BUNK

JAN

BUNK CONF

BUNK

BUNK

HALL

STAIR

CONTROL

STORAGE BAY 2

STORAGE BAY 3

OPEN TO MECHANICAL

A5

A6

A2

A1 A4

A3

A8

A7

ROOM BELOW

PCB10

C4-2

1/8" = 1'-0"H102

1 EXISTING PLAN - 2ND FLOOR

2nd Floor Lead Sample Results

Number Color Surface Substrate Result (mg/cm²) 2225 off-white door frame metal 0.00 2226 off-white wall wallpaper 0.00 2227 brown stall metal 0.00 2228 cream wall wallpaper 0.00 2229 cream door metal 0.00 2230 white shelf wood 0.00 2231 cream window sill wood 0.00 2232 white ledge joint compound 0.00 2233 white window sill wood 0.00 2234 white wall gwb 0.00 2235 cream wall wallpaper 0.00 2236 cream door metal 0.00 2237 cream door frame metal 0.00 2238 cream handrail metal 0.00 RENOVATE COM

BAT ALERT CELL (B1300)

SU

STAIN

ABLE EN

VIR

O

N M

EN

T

Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

2ND FLOOR ASBESTOS & LEAD SAM

PLE LOCATIONS & RESULTS0123

LEAD BASED PAINT SAMPLE

(<1mg/cm sq)(HUD)

LEAD BASED PAINT SAMPLE

(>1mg/cm sq)(HUD)

SEE LEAD BASED PAINT TABULATION

RESULTS FOR CONCENTRATION FOR

LEAD SAMPLE NUMBER

ASBESTOS SAMPLE LOCATIONS

NEGATIVE (<1% ASBESTOS)

ASBESTOS SAMPLE LOCATIONS

POSITIVE (>1% ASBESTOS)

SEE ASBESTOS TABULATED RESULTS

FOR ACM SAMPLE NUMBER

LEGEND

01234

01234

PCB PAINT SAMPLE LOCATIONS

NEGATIVE (NO PCBs DETECTED)

PCB PAINT SAMPLE LOCATIONS

POSITIVE (PCBs DETECTED)

SEE TABULATED RESULTS FOR

SAMPLE NUMBER & RESULTS

2nd Floor Asbestos Sample Results (Method EPA 600/R-93/116) Sample ID Description Result

A1 white wallpaper ND A2 white joint compound ND A2 brown/white gwb ND A3 carpet ND A3 yellow mastic ND A3 beige adhesive ND A4 carpet ND A4 yellow mastic ND A5 gray/white ceiling tile #1 ND A6 white/yellow ceiling tile #2 ND A7 white joint compound ND A8 yellow mastic ND

C4-2 black mastic ND

H

2nd Floor PCB by 3546/8082A (mg/kg)

Analyte Sample ID PCB10

Description tan wall paint Aroclor-1016 ND Aroclor-1221 ND Aroclor-1232 ND Aroclor-1242 ND Aroclor-1248 ND Aroclor-1254 ND Aroclor-1260 ND Aroclor-1262 ND Aroclor-1268 ND

Peter Beardsley

CE 10934REG IS T ER ED P R O F E S S IO NA L ENG INEER

08/22/2022

KITCHEN

LIVING

PANTRY

CLOS

BATH

STAIR

SERVER

COMMON

LINEN

BUNK BUNK

OPEN TO MECHANICAL

ROOM BELOW

2241 2240

A20

A22

A12

A11

A13

A14

A21

A23

A19

A18

A17

A10

A9

A16

A15

STORAGE BAY 2

STORAGE BAY 3

PCB11

1/8" = 1'-0"H103

1 EXISTING PLAN - 3RD FLOOR

3rd Floor Lead Sample Results

Number Color Surface Substrate Result (mg/cm²) 2239 cream wall wallpaper 0.00 2240 white wall wallpaper 0.00 2241 light gray door frame metal 0.00 2242 cream window frame wood 0.00 2243 off-white wall plywood 0.00 2244 off-white wall gwb 0.00 2245 off-white door metal 0.00 2246 white wall gwb 0.00 2247 white pipe metal 0.00 2248 white door frame metal 0.00 2249 cream exterior siding metal 0.00 2250 cream fire extinguisher cabinet metal 0.00 2251 cream island framing plywood 0.02

RENOVATE COM

BAT ALERT CELL (B1300)

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

3RD FLOOR ASBESTOS & LEAD SAM

PLE LOCATIONS & RESULTS0123

LEAD BASED PAINT SAMPLE

(<1mg/cm sq)(HUD)

LEAD BASED PAINT SAMPLE

(>1mg/cm sq)(HUD)

SEE LEAD BASED PAINT TABULATION

RESULTS FOR CONCENTRATION FOR

LEAD SAMPLE NUMBER

ASBESTOS SAMPLE LOCATIONS

NEGATIVE (<1% ASBESTOS)

ASBESTOS SAMPLE LOCATIONS

POSITIVE (>1% ASBESTOS)

SEE ASBESTOS TABULATED RESULTS

FOR ACM SAMPLE NUMBER

LEGEND

01234

01234

PCB PAINT SAMPLE LOCATIONS

NEGATIVE (NO PCBs DETECTED)

PCB PAINT SAMPLE LOCATIONS

POSITIVE (PCBs DETECTED)

SEE TABULATED RESULTS FOR

SAMPLE NUMBER & RESULTS

3rd Floor Asbestos Sample Results (Method EPA 600/R-93/116)

Sample ID Description Result A9 yellow corner trim mastic ND

A10 beige wallpaper ND A10 white/yellow adhesive ND A11 brown floor tile ND A11 black mastic <0.25% Chrysotile A12 beige cove ND A12 yellow mastic ND A12 white joint compound ND A13 yellow mastic ND A14 carpet ND A14 yellow mastic 0.73% Chrysotile A15 white joint compound ND A16 brown/white wall core ND A17 pink wallpaper ND A17 white/yellow adhesive ND A18 brown cove ND A18 yellow mastic ND A19 brown floor tile ND A19 black adhesive ND A20 white/yellow ceiling tile #2 ND A21 black sink coating ND A22 black stair tread ND A22 red mastic ND A23 brown sheet vinyl ND A23 yellow adhesive ND

H

3rd Floor PCB by 3546/8082A (mg/kg)

Analyte Sample ID PCB11

Description white caulk Aroclor-1016 ND Aroclor-1221 ND Aroclor-1232 ND Aroclor-1242 ND Aroclor-1248 ND Aroclor-1254 ND Aroclor-1260 ND Aroclor-1262 ND Aroclor-1268 ND

Peter Beardsley

CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER

08/22/2022

STORAGE

BAY 3

STORAGE

BAY 4

BOILER

TUBE PULL

SPACE

BOILER

ROOM

DE-BRIEF

COMMONS

MEN WOMEN

VEST

JANITOR

FIRE PUMP

ROOM

22782279

227222712275 2274

A30

A31

A34

A33

A32

B7

B2

B3

B4

B1B5B6

A35

PCB2

PCB1

PCB12

PCB4 ADI

B8

PCB3

1/8" = 1'-0"H104

1 EXISTING PLAN - BAYS 3 & 4

Bays 3 & 4 Asbestos Sample Results (Method EPA 600/R-93/116) Sample ID Description Result

B1 fireproofing ND B2 fireproofing ND B3 fireproofing ND B4 fireproofing ND B5 pink sealant ND B6 black adhesive 7.9% Chrysotile B7 black panel backing ND B8 black apron sealant ND

Bay 3 & 4 Asbestos Sample Results (Method EPA 600/R-93/116) Sample ID Description Result

A30 black cove ND A30 yellow mastic ND A31 brown/white wall ND A32 brown/white gwb ND A32 white joint compound ND A33 tan floor sealant ND A34 duct covering ND A35 tan floor sealant ND A35 gray coating ND

Bay 3 & 4 Lead Sample Results

Number Color Surface Substrate Result (mg/cm²) 2252 red wall metal 0.17 2253 white wall transite 0.00 2254 gray floor epoxy 0.00 2255 yellow ramp concrete 0.00 2256 red cross-brace metal 0.00 2257 tan door metal 0.00 2258 white wall metal 0.00 2260 yellow floor epoxy 0.00 2261 red/brown column metal 6.0 2262 brown column metal 0.08 2263 red back of wall metal 0.11 2264 red front of wall metal 0.16 2265 brown doorway framing metal 2.3 2266 yellow floor epoxy 0.00 2267 yellow floor concrete 0.00 2268 red/brown column metal 7.2 2269 white wall transite 0.00 2270 red door step metal 7.5 2271 brown floor bumper metal 4.4 2272 gray door metal 0.00 2274 dark brown I-beam metal 0.02 2275 yellow original floor striping concrete 2.3 2276 yellow new floor striping epoxy 0.13 2277 white wall fireproofing 0.09 2278 black column metal 4.6 2279 gray column metal 7.8 2280 orange equipment support metal 9.4

LEAD BASED PAINT SAMPLE

(<1mg/cm sq)(HUD)

LEAD BASED PAINT SAMPLE

(>1mg/cm sq)(HUD)

SEE LEAD BASED PAINT TABULATION

RESULTS FOR CONCENTRATION FOR

LEAD SAMPLE NUMBER

ASBESTOS SAMPLE LOCATIONS

NEGATIVE (<1% ASBESTOS)

ASBESTOS SAMPLE LOCATIONS

POSITIVE (>1% ASBESTOS)

SEE ASBESTOS TABULATED RESULTS

FOR ACM SAMPLE NUMBER

LEGEND

RENOVATE COM

BAT ALERT CELL (B1300)

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

BAY 3 & 4 ASBESTOS & LEAD SAM

PLE LOCATIONS & RESULTS

01234

01234

PCB PAINT SAMPLE LOCATIONS

NEGATIVE (NO PCBs DETECTED)

PCB PAINT SAMPLE LOCATIONS

POSITIVE (PCBs DETECTED)

SEE TABULATED RESULTS FOR

SAMPLE NUMBER & RESULTS

Bay 3 & 4 Asbestos Wipe Sample Results (Method

Sample ID Description Result (str/cm²) ADI top of electrical panel <52,000

H

Bays 3 & 4 PCB by 3546/8082A (mg/kg)

Analyte

Sample ID PCB1 PCB2 PCB3 PCB4 PCB12

Description gray floor tar floor sealant red structural steel paint tan exterior paint original yellow floor striping Aroclor-1016 ND ND ND ND ND Aroclor-1221 ND ND ND ND ND Aroclor-1232 ND ND ND ND ND Aroclor-1242 ND ND ND ND ND Aroclor-1248 ND ND ND ND ND Aroclor-1254 ND ND ND ND ND Aroclor-1260 ND ND 0.50 ND ND Aroclor-1262 ND ND ND ND ND Aroclor-1268 ND ND ND ND ND

Peter Beardsley

CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER

08/22/2022

ACM BLACK ADHESIVE

BOILER

TUBE PULL

SPACE

GENERATOR

ROOM

BOILER

ROOM

MEN WOMEN

JANITOR

FIRE PUMP

ROOM

C5

C4

C6 C1

C2

C3

PCB8

PCB9

1/8" = 1'-0"H105

1 EXISTING PLAN - MECHANICAL ROOMS

Mechanical Rooms Asbestos Sample Results (Method EPA 600/R-93/116) Sample ID Description Result

C1 brown/white gwb ND C2 gray Transite 30% Chrysotile C3 white fiberglass sealant ND C4 white fiberglass wrap ND C5 red sealant ND C6 white/silver pipe wrap ND

RENOVATE COM

BAT ALERT CELL (B1300)

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

MECHANICAL ROOMS ASBESTOS & LEAD SAMPLE LOCATIONS & RESULTS0123

LEAD BASED PAINT SAMPLE

(<1mg/cm sq)(HUD)

LEAD BASED PAINT SAMPLE

(>1mg/cm sq)(HUD)

SEE LEAD BASED PAINT TABULATION

RESULTS FOR CONCENTRATION FOR

LEAD SAMPLE NUMBER

ASBESTOS SAMPLE LOCATIONS

NEGATIVE (<1% ASBESTOS)

ASBESTOS SAMPLE LOCATIONS

POSITIVE (>1% ASBESTOS)

SEE ASBESTOS TABULATED RESULTS

FOR ACM SAMPLE NUMBER

LEGEND

01234

01234

PCB PAINT SAMPLE LOCATIONS

NEGATIVE (NO PCBs DETECTED)

PCB PAINT SAMPLE LOCATIONS

POSITIVE (PCBs DETECTED)

SEE TABULATED RESULTS FOR

SAMPLE NUMBER & RESULTS

Mechanical Rooms Lead Sample Results

Number Color Surface Substrate Result (mg/cm²) 2281 gray wall transite 0.03 2282 white wall gwb 0.00 2284 red door wood 1.2 2285 gray door wood 2.4 2286 dark green floor cement 2.0 2287 salmon floor cement 2.0 2288 brown wall transite 0.05 2289 black column metal 10.1 3111 tan wall gwb 15.3 3112 white wall gwb 13.9 3113 tan floor cement 15.5

H

Mechanical Rooms PCB by 3546/8082A (mg/kg)

Analyte Sample ID 8 9

Description tan & green floor paint dark yellow floor sealant Aroclor-1016 ND ND Aroclor-1221 ND ND Aroclor-1232 ND ND Aroclor-1242 ND ND Aroclor-1248 ND ND Aroclor-1254 ND ND Aroclor-1260 2.6 ND Aroclor-1262 ND ND Aroclor-1268 ND ND

Peter Beardsley

CE 10934REG IS T ER ED P R O F E S S IO NA L ENG INEER

08/22/2022

NOTE: TRANSITE PANELS IDENTIFIED IN GENERATOR ROOM AND BOILER ROOM. KNOWN

TRANSITE WALLS ARE LABELED WITH WARNING ADHESIVE "DANGER-ASBESTOS" STICKERS.

RENOVATE COM

BAT ALERT CELL (B1300)

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

LABORATORY REPORTS

H

Peter Beardsley

CE 10934REGIS T ER E D P R O FE S S IO NA L ENGINEER

08/22/2022

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

LABORATORY REPORTS

H

Peter Beardsley

CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER

08/22/2022

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

LABORATORY REPORTS

H

Peter Beardsley

CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER

08/22/2022

SU

STAIN

ABLE EN

VIR

O N

M

EN

T Juneau: 5438 Shaune D rive

907.452.5688 Anchorage: 3105 Lakeshore D

rive

EN

ER

G Y, H

EALTH

& SAFETY

Fairbanks: 2400 C ollege R oad

C orporate N o.: AEC C

LABORATORY REPORTS

H

Peter Beardsley

CE 10934REG IST ER ED PR O FE S S IO NA L ENGINEER

08/22/2022

SUMP

EXISTING BOLLARD, TYP.

EXISTING FIRE HYDRANT

EXISTING ASPHALT

BUILDING 1300

EXTERNAL STAIRS TO ROOF

PROPOSED BOLLARDS

TYP. OF 10

S511

EXISTING LANDING

TO REMAIN

CONCRETE LANDING

1, 2

C700

CONCRETE LANDING

1, 2

C700

PROPOSED BOLLARDS

S511

PROPOSED BOLLARDS

CENTERED ON EDGE

OF DOORWAY

S511

2'-0"

2'-0"

5' -0

7'-0" 1'-6"

10" EACH SIDE

6"

SITE PLAN1

C200 1" = 10'

Jay A. Baxter

No. CE12976 19-Aug-2022

1' -0

1'

-0

6" BOLLARD, TYP. 3

S511

5' -0

5'-0"

CONCRETE LANDING PLAN VIEW1

C700 NOT TO SCALE

6"

ALIGN RELATIVE TO THE

HINGE SIDE OF THE JAMB

WIDTH PER PLANS

#4 REBAR AT 12" O.C. EACH WAY

EXISTING GRADE

FRONT PROFILE

IN SITU

SOIL

LANDING ELEVATION TO

MATCH INTERIOR FINISH

FLOOR ELEVATION

TOP OF

EXISTING

GRADE

CONNECTION TO DOORWAY

1/2" DEEP SEALANT W/

1/4" RAD AT SURFACE

SLOPE @ 2% (TYP.)

EXISTING WOOD

PLATFORM ON TOP

OF EXISTING APRON

LANDING ABOVE EXISTING GRADE2

C700 NOT TO SCALE

FELT

6" APPROX.

Jay A. Baxter

No. CE12976 19-Aug-2022

IN SITU SOIL

CONCRETE

EARTH

GYPSUM

RIGID INSULATION

MASONRY CONCRETE

PLYWOOD

MATERIAL LEGEND

BATT INSULATION

SPRAY FOAM INSULATION

EXISTING

CONSTRUCTION

NO ARCHITECTURAL WORK

THIS AREA

BATT INSULATION

EXISTING

CONSTRUCTION DETAIL

ARCHITECTURAL SYMBOL LEGEND

150 SF

Room Name

DETAIL NAME

DETAIL NUMBER

SHEET LOCATION

DETAIL SCALE

TRUE NORTH

GRID LINE

ROOM NAME

ROOM NUMBER

PLAN NORTH

DETAIL NUMBER

SHEET LOCATION

SIMILAR

REVISION

SPOT ELEVATION

SEE OTHER DISCIPLINES FOR ADDITIONAL SYMBOLS

KEYED NOTE

DOOR TAG

A100

A100

EXTERIOR ELEVATION

SHEET LOCATION

DETAIL NUMBER

INTERIOR ELEVATION

SHEET LOCATION

DETAIL NUMBER

DETAIL NUMBER 4

A

BUILDING SECTION

DETAIL NUMBER

SHEET LOCATION

SIMILAR

WALL SECTION

WINDOW TYPE

ROOM AREA

1/8" = 1'-0"A101 View Name

1/4" / 1'-0"

.SPOT SLOPE

101ROOM NUMBER

A101

SIM

A101

SIM

101A

1. SEE OTHER DISCIPLINES FOR ADDITIONAL ABBREVIATIONS.

2. SEE GENERAL SHEETS FOR CODE ABBREVIATIONS.

3. SEE ASSEMBLY TYPES FOR HYPHENATED ASSEMBLY TAGS

(I.E. C-A1, W01-3A, AND WX-3A).

4. SEE MATERIAL SCHEDULE FOR HYPHENATED MATERIAL TAGS

(I.E. ACT-1, CPT-1, AND RB-1).

5. SEE ROOM AND DOOR SCHEDULE FOR SPECIFIC RELEVANT

ABBREVIATIONS.

6. SOME ABBREVIATIONS LISTED BELOW MAY NOT BE USED IN

THIS PROJECT.

(E) EXISTING

ADA AMERICAN DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

CFCI CONTRACTOR FURNISHED CONTRACTOR INSTALLED

CFOI CONTRACTOR FURNISHED OWNER INSTALLED

CMU CONCRETE MASONRY UNIT

CONC CONCRETE

ELEC ELECTRICAL

FV FIELD VERIFY

GA GYPSUM ASSOCIATION

GYP GYPSUM BOARD

IBC INTERNATIONAL BUILDING CODE

INSUL INSULATION

ITSP INSULATED TRANSLUCENT SANDWICH PANEL

MAX MAXIMUM

MECH MECHANICAL

MFSD MANUFACTURER'S STANDARD

MIN MINIMUM

NIC NOT IN CONTRACT

OC ON CENTER

OD OVERFLOW DRAIN

OFOI OWNER FURNISHED OWNER INSTALLED

OFCI OWNER FURNISHED CONTRACTOR INSTALLED

OSB ORIENTED STRAND BOARD

OTS OPEN TO STRUCTURE

PLY PLYWOOD

RD ROOF DRAIN

SIP STRUCTURAL INSULATED PANEL

SPEC SPECIFICATION

STC SOUND TRANSMISSION CLASS

STRUC STRUCTURAL

TBD TO BE DETERMINED

TYP TYPICAL

UL UNDERWRITERS LABORATORY

VTR VENT THROUGH ROOF

ARCHITECTURAL STANDARD ABBREVIATIONS

ARCHITECTURAL PROJECT SPECIFIC ABBREVIATIONS

NA NOT APPLICABLE

WX-A1

WALL ASSEMBLY CATEGORY - FUNCTION

WALL BUILDING ENVELOPE DESIGNATION

WALL ASSEMBLY MODIFIER

WALL ASSEMBLY CATEGORY - FUNCTION

PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.

WF WALL - FOUNDATION

WP WALL - PARAPET

WR WALL - RETAINING

WX WALL - EXTERIOR

WALL BUILDING ENVELOPE DESIGNATION

A EIFS / FOUNDATION

B RAINSCREEN

C IMP

D OTHER

WALL ASSEMBLY MODIFIER

NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY TYPES.

THE BELOW ARE COMMONLY USED EXAMPLES. SEE

ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.

1 TYPICAL

EXTERIOR ASSEMBLY TAG LEGEND - WALL

R-A1

ROOF ASSEMBLY CATEGORY - FUNCTION

ROOF ASSEMBLY MODIFIER

ROOF ASSEMBLY CATEGORY - FUNCTION

R ROOF

RS ROOF - SOFFIT

ROOF BUILDING ENVELOPE DESIGNATION

A EIFS / EPDM / FOUNDATION

B RAINSCREEN / ATTIC

C IMP

D OTHER

ROOF ASSEMBLY MODIFIER

NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY

TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.

SEE ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.

1 TYPICAL

EXTERIOR ASSEMBLY TAG LEGEND - ROOF

ROOF BUILDING ENVELOPE DESIGNATION

W01-3A

WALL ASSEMBLY CATEGORY - FUNCTION

WALL SHEATHING DESIGNATION

WALL FRAMING MEMBER SIZE

WALL ASSEMBLY MODIFIER

WALL ASSEMBLY CATEGORY - FUNCTION

PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.

W WALL - INTERIOR

WALL SHEATHING DESIGNATION

ASSEMBLIES MAY NOT INCLUDE A SHEATHING DESIGNATION.

THE SHEATHING DESIGNATION REFERS TO THE NUMBER OF

SHEATHING LAYERS ON EACH SIDE OF THE FRAMING MEMBER.

00 FIRST SIDE (0 LAYERS) + SECOND SIDE (0 LAYERS)

01 FIRST SIDE (0 LAYERS) + SECOND SIDE (1 LAYERS)

02 FIRST SIDE (0 LAYERS) + SECOND SIDE (2 LAYERS)

03 FIRST SIDE (0 LAYERS) + SECOND SIDE (3 LAYERS)

04 FIRST SIDE (0 LAYERS) + SECOND SIDE (4 LAYERS)

11 FIRST SIDE (1 LAYERS) + SECOND SIDE (1 LAYERS)

12 FIRST SIDE (1 LAYERS) + SECOND SIDE (2 LAYERS)

13 FIRST SIDE (1 LAYERS) + SECOND SIDE (3 LAYERS)

14 FIRST SIDE (1 LAYERS) + SECOND SIDE (4 LAYERS)

22 FIRST SIDE (2 LAYERS) + SECOND SIDE (2 LAYERS)

23 FIRST SIDE (2 LAYERS) + SECOND SIDE (3 LAYERS)

24 FIRST SIDE (2 LAYERS) + SECOND SIDE (4 LAYERS)

33 FIRST SIDE (3 LAYERS) + SECOND SIDE (3 LAYERS)

34 FIRST SIDE (3 LAYERS) + SECOND SIDE (4 LAYERS)

44 FIRST SIDE (4 LAYERS) + SECOND SIDE (4 LAYERS)

INTERIOR ASSEMBLY TAG LEGEND - WALL

BUILDING ENVELOPE LEGEND

SEE EXTERIOR ASSEMBLY TYPES, EXTERIOR DETAILS,

MATERIAL SCHEDULE, AND SPECIFICATIONS FOR

ADDITIONAL INFORMATION. PROJECTS MAY NOT INCLUDE

ALL BUILDING ENVELOPE CATEGORIES.

DIRECTION

OF DRYING

BE-1 OR 2: FOUNDATION MEMBRANE

BE-4: INTERIOR AIR/VAPOR BARRIER

BE-5 OR 6: EXTERIOR AIR/WATER BARRIER

BE-7,8, OR 9: ROOF UNDERLAY

BUILDING ENVELOPE COMPONENT

BUILDING ENVELOPE METAL FLASHING

DESCRIBES THE DIRECTION OF AIRFLOW IN A

VENTED OR VENTILATED ASSEMBLY

DESCRIBES THE DIRECTION AN ASSEMBLY

WILL DRY. PERMEABLE MATERIALS REQUIRED

TO DRY AS SHOWN

C-A1

CEILING ASSEMBLY CATEGORY

CEILING ASSEMBLY MODIFIER

CEILING ASSEMBLY CATEGORY

PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.

C CEILING

CEILING MATERIAL DESIGNATION

LETTERS A THRU Z REPRESENT DESCRIPTIONS OF

ASSEMBLY TYPES. THE BELOW ARE COMMONLY USED

EXAMPLES. SEE ASSEMBLY TYPES FOR ADDITIONAL

DESIGNATIONS.

A ACOUSTIC CEILING TILE

G GYPSUM BOARD

S SPECIALTY MATERIAL

CEILING ASSEMBLY MODIFIER

NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY

TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.

SEE ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.

1 TYPICAL

INTERIOR ASSEMBLY TAG LEGEND - CEILING

CEILING MATERIAL DESIGNATION

F-W1

FLOOR ASSEMBLY CATEGORY - FUNCTION

FLOOR ASSEMBLY MODIFIER

FLOOR ASSEMBLY CATEGORY - FUNCTION

FLOORS ON GRADE OR THOSE COMPRISING THE EXTERIOR

ENVELOPE OF THE BUILDING ARE CONSIDERED EXTERIOR.

PROJECTS MAY NOT INCLUDE ALL ASSEMBLY CATEGORIES.

F FLOOR - INTERIOR

FLOOR MATERIAL DESIGNATION

LETTERS A THRU Z REPRESENT DESCRIPTIONS OF

ASSEMBLY TYPES. THE BELOW ARE COMMONLY USED

EXAMPLES. SEE ASSEMBLY TYPES FOR ADDITIONAL

DESIGNATIONS.

W WOOD

FLOOR ASSEMBLY MODIFIER

NUMBERS REPRESENT DESCRIPTIONS OF ASSEMBLY

TYPES. THE BELOW ARE COMMONLY USED EXAMPLES.

SEE ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.

1 TYPICAL

2 FIRE RATED

INTERIOR ASSEMBLY TAG LEGEND - FLOOR

FLOOR MATERIAL DESIGNATION

WALL FRAMING MEMBER SIZE

FURRING AND METAL STUDS

0 7/8" FURRING CHANNELS

1 1 5/8" METAL STUDS

2 2 1/2" METAL STUDS

3 3 5/8" METAL STUDS

4 4" METAL STUDS

6 6" METAL STUDS

8 8" METAL STUDS

SHAFT WALLS

2 2 1/2" METAL CH STUDS

4 4" METAL CH STUDS

6 6" METAL CH STUDS

WOOD STUDS

4 2x4 WOOD STUDS 6 2x6 WOOD STUDS 8 2x8 WOOD STUDS

CMU

2 1 5/8" CMU

4 3 5/8" CMU

6 5 5/8" CMU

8 7 5/8" CMU

10 9 5/8" CMU

12 11 5/8" CMU

CONCRETE

# CONCRETE THICKNESS

WALL ASSEMBLY MODIFIER

LETTERS A THRU Z REPRESENT DESCRIPTIONS OF ASSEMBLY

TYPES. THE BELOW ARE COMMONLY USED EXAMPLES. SEE

ASSEMBLY TYPES FOR ADDITIONAL MODIFIERS.

- TYPICAL

A ACOUSTIC

F FIRE RATED

G FIRE AND SOUND RATED

H FIRE AND SOUND RATED - SEE ASSEMBLY TYPES

K TILE

L TILE AND SOUND RATED

P PLYWOOD

S SOUND RATED

W WOOD STUD

X WOOD STUD, FIRE RATED

Y WOOD STUD, FIRE AND SOUND RATED

Z WOOD STUD, SOUND RATED

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

Q.

R.

S.

T.

U.

V.

W.

ARCHITECTURAL NOTES DESCRIBE WORK COMPRISING

THE ENTIRE ARCHITECTURAL DISCIPLINE.

SHEET NOTES DESCRIBE WORK COMPRISING THE ENTIRE

SHEET ON WHICH THE NOTES APPEAR INCLUDING

SHEETS ON WHICH THE NOTES ARE REFERENCED.

CONSTRUCTION DOCUMENTS ARE PREPARED FOR THE

PURPOSES OF COMMUNICATING DESIGN INTENT.

DRAWINGS ARE GRAPHIC REPRESENTATIONS CONVEYING

THE QUANTITATIVE EXTENT AND RELATIONSHIP BETWEEN

PROJECT ELEMENTS.

SPECIFICATIONS ARE WRITTEN REPRESENTATIONS

CONVEYING THE QUALITATIVE REQUIREMENTS OF

PROJECT ELEMENTS.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A

COMPLETE AND FINISHED PRODUCT FULFILLING THE

INTENT OF THE CONSTRUCTION DOCUMENTS.

THE TERM 'NEW' MAY BE USED TO DISTINGUISH NEW

FROM EXISTING IN SOME INSTANCES. OMISSION OF THE

TERM 'NEW' IS NOT NECESSARILY AN INDICATION THAT

THE ELEMENT IS EXISTING.

THE TERM 'ALL' MAY BE USED TO CLARIFY SCOPE.

OMISSION OF THE TERM 'ALL' IS NOT NECESSARILY AN

INDICATION THAT THE SCOPE IS LIMITED.

SEE GENERAL CODE INFORMATION AND CODE PLAN.

PROVIDE CONSTRUCTION IN COMPLIANCE WITH OSHA.

COORDINATE ARCHITECTURAL WORK WITH CIVIL,

HAZARDOUS MATERIALS, STRUCTURAL, MECHANICAL,

FIRE PROTECTION, ELECTRICAL, AND OTHER DISCIPLINES.

SEE STRUCTURAL FOR SPECIFIC INFORMATION

REGARDING LOAD BEARING MEMBERS, MECHANICAL

FASTENERS, MASTIC ADHESION, AND STRUCTURE.

FURNITURE IS SHOWN FOR COORDINATION PURPOSES

ONLY. FURNITURE IS GOVERNMENT FURNISHED AND

GOVERNMENT INSTALLED UNLESS NOTED OTHERWISE.

PATCH, REPAIR, AND REFINISH EXISTING SURFACES TO

REMAIN, AFFECTED BY WORK.

FIELD VERIFY DIMENSIONS SHOWN TO EXISTING

CONSTRUCTION PRIOR TO WORK. NOTIFY ARCHITECT

WHERE DISCREPANCIES ARE DISCOVERED.

DIMENSIONS AT EXISTING CONSTRUCTION ARE

MEASURED FROM FACE OF EXISTING FINISH UNLESS

NOTED OTHERWISE.

DIMENSIONS AT NEW CONSTRUCTION ARE MEASURED

FROM FACE OF FRAMING UNLESS NOTED OTHERWISE.

CONFIRM DIMENSIONS INDICATED WITH 'FIELD VERIFY'

AND/ OR 'FV' PRIOR TO WORK.

DIMENSIONS INDICATED AS 'CLEAR' REQUIRE MINIMUM

CLEARANCE MEASURED TO FINISHED FACES, UNLESS

NOTED OTHERWISE.

DIMENSIONS INDICATED WITH '+/-' BRING THE

CONTRACTORS ATTENTION TO AREAS WITH FLEXIBILITY

GREATER THAN ADJACENT AREAS NOT OTHERWISE

INDICATED.

SEE SPECIFICATIONS FOR ALLOWABLE TOLERANCES.

CONFIRM MANUFACTURERS INSTRUCTIONS CONFORM TO

SPECIFIED TOLERANCES.

SEE DETAILS FOR DIMENSION AND LEVEL REFERENCE

POINTS.

ARCHITECTURAL…