USDA FOREST SERVICE, R4

D2 DISTRICT RAC FENCING PROJECT

Diamond Mountain Wildlife Exclosure- BIG GAME EXCLOSURE FENCE

a. Removal and disposal of all existing structures including steel and/or wood fence posts, t-posts, net wire, wood stays, poles and barbed wire. The dimensions of the existing exclosure are the same as the new exclosure shown on the drawings

b. Clear woody vegetation 4’ swath along entire outside edge of exclosure

c. Grading along the fence line is not required. In general, the fence shall be erected on the undisturbed, natural ground. The style of fence construction including the post spacing shall be as shown on the drawings.

d. New fencing is to be constructed of 2 rows of 48” "no climb" horse fencing with 2"x4" spaces.

e. New posts shall be 10’ t-posts, pounded to a depth of 12" @ 10’ O.C. spacing

f. Corner braces and h-braces shall be steel pipe w/ 10’ length pounded or cemented to a depth of 24”, 3-post design, with single 10’ cross member placed 3/4 up the post. Corners shall have a 2 7/8” top rail and 2 rows of 48” “no climb” horse fencing

g. Contractor is responsible for cutting the steel pipe to the specific lengths and providing their own equipment to cut the pipe

h. Install a 4’x 6-8’ green gate

i. Fence is approximately 740 ft

Diamond Mountain Wildlife Exclosure- CATTLE EXCLOSURE FENCE

a. Remove all existing fencing

b. Clear woody vegetation 4’ swath along entire outside edge of exclosure.

c. Grading along the fence line is not required. In general, the fence shall be erected on the undisturbed, natural ground. The style of fence construction including the post spacing shall be as shown on the drawings.

d. New Fencing is to be constructed of standard, wildlife-friendly 4 strand barbed wire, 5.5-6 ft t-posts and steel pipe double H braces

e. Barbed wire shall be 2 strands of 12-12.5 gauge zinc-coated wire wrapped around each other, 14 gauge barbs spaced 5-6 inches apart.

f. Staples shall be 9 gauge or heavier and have a minimum length of 1-1/2 inches.

g. Wire clips shall be 12.5 gauge galvanized steel wire fasteners.

h. New posts shall be 5.5-6 ft. t-posts, pounded to a depth of 12" @ 10’ O.C. spacing

i. Two wood stays will be placed evenly between t-posts. Wood stays shall be minimum 2 inch diameter, maximum 3 inch diameter

j. Corner braces and h-braces shall be steel pipe w/ 7’ length pounded or cemented to a depth of 24”, 3-post design, with single 7’ cross member placed 3/4 up the post

k. All pipe will be welded together

l. Contractor is responsible for cutting the steel pipe to the specific lengths and providing their own equipment to cut the pipe

m. Fence is approximately 455 ft

GARTRELL SPRING EXCLOSURE FENCE

1 The Contractor shall construct a post and pole fence in accordance with these specifications and the location as shown on the drawing and as staked by the Project Manager.

2. Grading along the fence line is not required. In general, the fence shall be erected on the undisturbed, natural ground. The style of fence construction including the post spacing shall be as shown on the drawings.

3. Construct Gartrell Spring Exclosure with cedar posts buried 2 1/2-3 feet and 8 feet apart

4. Poles shall be sound Lodgepole Pine, free from rot, disease, or insects. Poles shall have a

3 inch minimum tip diameter and an 18-foot minimum length. Poles shall be peeled or unpeeled and trimmed smooth of limbs and snags.

5. Poles shall be fastened to the post using 3/8-1/2 inch bolts

6. Install one 4 ft green 1600 series powder river gate (see drawing)

7. Fence perimeter is approximately 900 ft.

READER/BASSETT/HWY 191 BOUNDARY FENCE

a. Remove all existing fencing. All trees, brush and other obstacles which interfere with proper construction of the fence shall be removed in advance. Material so removed shall be disposed of properly off the Forest.

b. Clear woody vegetation along entire fenceline (8’ swath)

c. Grading along the fence line is not required. In general, the fence shall be erected on the undisturbed, natural ground. The style of fence construction including the post spacing shall be as shown on the drawings.

d. New Fencing is to be constructed of standard, wildlife-friendly 4 strand barbed wire, t-posts and steel pipe double H braces

e. Barbed wire shall be 2 strands of 12-12.5 gauge zinc-coated wire wrapped around each other, 14 gauge barbs spaced 5-6 inches apart. Smooth wire shall be 12-12.5 gauge zinc-coated wire.

f. Staples shall be 9 gauge or heavier and have a minimum length of 1-1/2 inches.

g. Wire clips shall be 12.5 gauge galvanized steel wire fasteners.

h. New t-posts shall be 5.5-6 ft. 1.33 lb. @ 10’ O.C. spacing in trees and 12’ O.C. in open areas.

i. All steel posts (line posts) shall be driven to depths shown on drawings with the top of the anchor plate is embedded 4 inches minimum.

j. Two wood stays will be placed evenly between t-posts. Wood stays shall be minimum 2 inch diameter, maximum 3 inch diameter

k. Corner braces and h-braces shall be steel pipe w/ 7’ length pounded or cemented to a depth of 24”, 3-post design, with single 7’ cross member placed 3/4 up the post

l. All pipe will be welded together

m. Contractor is responsible for cutting the steel pipe to the specific lengths and providing their own equipment to cut and weld the pipe

n. When a fence line approaches a ditch, gully, or depression, the last post on level ground shall be placed close enough to the edge of the drop-off that the wire may be strung to a post in the depression without touching the ground.

o. When the depth of a depression on a fence exceeds the total vertical wire spacing over a maximum horizontal run of 2 spaces, an extra fence shall be constructed through the depression or sag bracing installed.

p. Gates shall be 12 feet wide in length and placed in the original locations. Gates shall be green 1600 series 6 rail powder river tube gates.

q. Fence is approximately 2.0 miles

CATTAIL POND DIAMOND MOUNTAIN

a. Reconstruct existing pond (currently 45 ft diameter)

b. Clean and restructure dam and overflow according to drawings and specifications

ATV CATTLEGUARDS AND GATES

a. Install five 84-inch wide custom ATV cattleguards in COR designated areas along fence as manufactured by EASY FENCE Company or approved equal

b. Install H-braces using steel pipe w/ 7’ length pounded or cemented to a depth of 24”, 3-post design, with single 7’ cross member placed 3/4 up the post

c. Install 5 gates that shall be 12 feet wide in length and placed adjacent to each cattleguard (see drawings). Gates shall be green 1600 series 6 rail powder river tube gates.

CLEARING AND GRUBBING

Live pines (lodgepole and ponderosa) and spruce if in abundance. These guidelines do not pertain to aspen, Douglas-fir, or subalpine fir).

1. In areas of abundant tree growth, all lopped slash greater than 3 inches in diameter should be cut to two-foot lengths and scattered in areas of maximum sunlight to promote drying.

2. In the event that cut trees are kept for later administrative use: older dead trees (one year after the tree has died) can be safely stored or used in susceptible sites because the living tissue under the outer bark has dried sufficiently and is not attractive to the insect.

3. Stumps along the fenceline must be cut less than 6 inches.

4. A 8 -foot corridor on the wire side of the fence and 4 ft corridor on the other side will be cleared.

5. A wood cutting permit must be obtained if wood is removed for personal use (see Forest Products Removal Permit conditions form FS-2400-1).

FIELD WELDING

1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.

2. Obtain fusion without undercut or overlap.

3. Remove welding flux immediately.

4. At exposed connections, finish exposed welds and surfaces smooth and blended so no roughness shows after finishing and contour of welded surface matches that of adjacent surface.

5. Welded connections shall be made by certified welders in accordance with AWS B1.1 structural welding code. All connections shall be made by minimum 3/16” continuous fillet welds.

6. The exclosures shall be fabricated in accordance with the dimensions and details shown on the drawings. Ends of pipe members shall be coped to approximately fit and welded, using a continuous fillet weld. All exposed pipe ends shall be ground smooth.

7. Post shall be erected plumb and at the desired elevation. Posts shall be pounded into the ground to the depths indicated on the drawings.

8. The Contractor will be required to cut all pipes to correct lengths specified on the drawings.

Saddles shall be cut into pipe to ensure snug fit between top-rail and posts and H-braces and posts.

9. Welding must be pre-approved by the District Ranger before construction begins

10. Weld in the spring or with sufficient soil moisture to reduce chance of fire (fire restriction may inhibit construction beginning in late July or August and may require the following:

welding only with winds less than 10 mph, provide fire extinguisher, shovel, and an additional person to watch for sparks, provide 50 gallons of water and pump to distinguish sparks as needed).