Environmental Design, LLC. r .,,,~ Septic Design~ Wetlands~ Site Planning ~Excavati~; ·" -1/AIIM£D
901 L Street, Centralia, WA 98531 Phone: (360) 219-3343
April 22, 2019 ~ ,,,,_,,,.... •C-o
1\PPiiUVt:.
Prepared For:_ THUP,STON 80UNTY HEALTH
IHS (Pierce) _ , _ -P/ J!Jfe, BY .
4060 Wheaton Way, Suite~,-.1 E u.f2'..t.~-..z-_.__
Bremerton, WA 98310
Site Address:
10427 Mullen Road SE, Olympia
County: Thurston REVISION Tax Parcel Number: 21831111300
THURSTON COUNlY
RECEIVED
AUG 02 2019
Purpose: DEVELOPMENT SERVICES A site and soil evaluation was completed for the property located 10427 Mullen Road SE in Olympia on February 17, 2019 by Environmental Design, LLC. The purpose of the site and soil evaluation is to determine the suitability of an On-Site Wastewater system. In order to determine if a site is suitable a minimum of three test pits were dug and evaluated for suitability. The site was evaluated to determine that the slope and size were suitable and to determine if the proposed on-site wastewater would be able to meet county and Washington State WAC 246-272A regulations.
Proposal:
The client has an existing 3 bedroom and 1 bedroom residence being served by a failing septic system.
For a)l'-bedroom system the estimated wastewater produced is 600 gallons per day based on the calculation of each bedroom prod,ucing 120 gallons per day. -11,-,u- t:r a. ·"{ ~ /~ wl1Z-'"1 160.,-CvlW1· <A.fity-'~ 'L,~b 'j..,/1/()AJ;f Pf.r,19..-...I Jv ~ l ~~ Site Description: .Jo 'K ~,.. ~ ~ r'Z./~ ~,? ~ The site has a 10-15% slope in the proposed drainfield. The parcel is about 0.4 acres in size and is J?/),'1 located in Section 10 of Township 18 North of Range 01 West.
Hydrology:
The site appears to be well drained and there did not appear to be any areas of ponding in the proposed on-site wastewater locations.
Water Source:
The water source is an existing shared well connection. The well is located 100 feet away from the proposed On-Site Wastewater system to meet the requirements of WAC 246-272A.
Soil Description:
According to the Natural Resources Conservation Service (NRCS) the property soil is mapped as a Indianola Laomy Sand Series according to the U.S.D.A Natural Resources Conservation Service Soil Survey of Thurston County, Washington (1980). The test pits were not consistent with the mapped series.
Job Number: 2018-341 Client Name: Pierce
The NRCS describes the Indianola Loamy Sandy series as very deep and somewhat excessively drained soil located on terraces. In a representative profile, the surface layer is dark reddish brown loamy sand about 6 inches thick. The upper portion of the subsoil extends to a depth of 7 inches and is dark reddish brown loamy sand. The lower 12 inches of the subsoil is dark brown loamy sand. The upper portion of the substratum is dark yellowish brown sand and extends to a depth of 10 inches. The lower portion extends to a depth of 60 inches or more and is olive brown sand.
Test Pit Description:
In order to complete a site and soil evaluation according to WAC 246-272A a minimum of three test pits need to be evaluated. For this site a total of 1 test pits were evaluated and labeled in the field. The test pits are as described below:
Test Pit#1 0-50" Brown coarse sand 50-70" Brown extremely gravelly coarse sand
Not restrictive
Soil Loading Rate:
The type of soil appears to be a Type 3 with a soil loading rate of 0.8 according to WAC 246-272A.
System Requirements:
The site appears to be suitable for a pressure distribution bed system in the proposed drainfield location. The system requirements are concluded based on the suitability of the soil, the slope of the site and the site conditions.
Conclusion:
The site described as 10427 Mullen Road SE in Olympia appears to have a slope of about 5-10% in the proposed drainfield area. The site has a suitable soil depth of 70+" in the proposed drainfield location and is suitable for a pressure distribution bed system to serve the existing residences.
Report Completed by:
Becky Rieger Licensed Designer
2 Job Number: 2018-341 Client Name: Pierce
-VICINITY MAP
EXISTING DRIVEWAY
EXISTING 3 BEDROOM
RESIDENCE
EXISTING 1 BEDROOM
RESIDENCE
I
I I
I
I I
I
I I
I
I I
I
I I I
I I I
I I
I
+/- 50 FT
I-u.
('I')
I , I
I I
I
I I
+/-50 FT
l
Ii w z :::::i w ll.
0::::
ll.
l:i:
r-- ('I') u~ ~<c~ cJi u~ ~<c~
<i:J~
:1/-'
/4 -~~ ,/c;
, 'S:-<v /' ..y , , I , , I I
I
I I
I
I I
I
I I
I
I I I
I I
Environmental Design, LLC.
Septic Design • Wetlands • Mapping
901 L Street Centralia, Wa. 98531
(360) 219-3343
N ,,,.
LEGEND
J: llJB lijiil TEST PIT
& EXISTING 'wELL
.t PRll'DSEll 'wELL
~ POWER
0 STlH'
0 40 80 - -- -1" = 40 FT
APPRO'VED
THURSTON COUNT~
DATE2-llj':lj~ BY , ~
THE PROPERTY LINES IN THIS MAP ARE
APPROXIMATE AND ARE NOT INTENDED
TO BE USED AS A SURVEY.
CUENT NAME: IHS (PIERCE)
MAIUNG ADDRESS: 4060 \./HEATON \,/ A Y, SUITE E
BREMERTON, \.IA 98310
PHONE NUMBER: 360-792-1235
SITE ADDRESS: 10427 MULLEN RD SE, DL YMPIA
PARCEL NUMBER: 21831111300
PERMIT NUMBER:
DRAITTD BY: BJR JOB NUMBER: 2018-341
REVIEWED BY: BJR DATE: 07/31/2019
S-T-R: 31-18N-01E
PAGE 1 OF4
EXISTING DRIVEWAY
PROPOSED 1 Ox25 BED SYSTEMS (X3)
SEE PAGE 4 FOR DETAILS
EXISTING 3 BEDROOM
RESIDENCE
I
I I
I I
I
I I
I
I I
I
PROPOSED PUMP CHAMBER/
SEE PAGE 3 FOR DETAIL/
PROPOSED SEPTIC TANK
SEE PAGE 3 FOR DET41LS
I I
I
EXISTING SEPTIC "fANK
TANK CAN BE RE-USED IF
TANK MEETS CURRENT CODE
AND IS WATER.'l"IGHT
SEE PAGE 3 FOR ~TAILS
I
EXISTING 1 sEbRoOM
RES}DENCE
99.0 w z :J w a..
0::
a..
I I
I I
I
I I
I
I I
I L-...L,----------':
I I I I r
EXISTING SEPTIC TANK SHALL
BE PUMPED BY AN APPROVED
PUMPER, HAVE LID REMOVED
AND VOID FILLED '111TH SOIL
OR GRAVEL AS PER
w'AC 246-272A--,0300, Environmental Design, LLC.
Septic Design • Wetlands • Mapping
901 L Street Centralia, Wa. 98531
(360) 219-3343
LEGEND
X lfJB
N
~ TEST PIT
& EXISTING \/ELL
f>w PRIPllSED 'JELL p~
PINER
0 ST\H'
0 30 60 - -- -1" = 30 FT
APPROVED
THURSTON COUNTY flE,lL~ DATE £/,I-? h BY fl~ -
--.....:l~~
CLIENT NAME: IHS (PIERCE)
MAIUNG ADDRESS: 4060 w'HEA TON \,,/ A Y, SUITE E BREMERTON, w'A 98310
PHONE NUMBER: 360-792-1235
SITE ADDRESS: 10427 MULLEN RD SE, □L YMPIA
PARCEL NUMBER: 21831111300
PERMIT NUMBER:
DRAFTED BY: BJR JOB NUMBER: 2018-341
REVIEWED BY: BJR DATE: 07/31/2019
S-T-R: 31-18N-01E
PAGE20F4
INSTALLATION NOTE: Pump and controls must be connected to the electrical system in the uphill 3-bedroom residence. There are no available breakers in the downhill 1-bedroom residence.
CLEANOUT 24" TANK LID
CLEAN OUT
ELE.: 78.7
TO GRADE
"PVC
SEPTIC TANK INSTALLATION:
24" TANK RISER
24" TANK ADAPTER
EFFLUENT FILTER
ORENCO BIOTUBE
#f:TPS043628
- 1 /16" MESH REQUIRED
1150 GALLON SEPTIC TANK
Scale: 1" = 2'
1) EXCAVATE HOLE DEEP ENOUGH FOR THE TANK AND BACK
FILL DEPTH.
2) IF SURFACE WATER IS ENCOUNTERED DURING EXCAVATION
TANKS MUST BE SECURED TO PREVENT FLOATING. IT IS THE
RECOMMENDATION OF ENVIRONMENTAL DESIGN THAT ALL
TANKS BE SECURED ON EACH INSTALL.
3) MAKE SURE BOTTOM OF TANK HOLE IS LEVEL AND THE SOIL IS
UNDISTURBED TO PREVENT SETTLING.
4) IF THE EXCAVTION IS TOO DEEP FILL THE HOLE IN AS
NECESSARY USING PEA GRAVEL OR WASHED SAND UNTIL THE
TANK IS AT THE PROPER ELEVATION
5) TANKS SHALL BE INSTALLED TO ENSURE POSITIVE FLOW AT
ALL TIME BY INSTALLING THE INLET INVERT OF THE SUCCESSIVE
TANK A MINIMUM OF 2 INCHES BELOW THE OUTLET INVERT OF
THE PRECEEDING TANK.
6) ALL CLEANOUTS, INSPECTION AND ACCESS RISERS MUST BE
ADEQUATELY SEALED SO THEY ARE WATER TIGHT.
7) BACKFILLING _THE TANKS MUST BE COMPLETED ACCORDING
TO THE MANUFACTURER'S RECOMMENDATIONS AND SHALL NOT
DAMAGE THE TANKS.
8) SLOPE GRADE AWAY FROM RISERS.
VALVc.:
MANUFACTURER: ZOELLER
VALVc.: #30-0101 TRI-CHECK CHECK VALVc. / BALL VALVc./ UNION COMBO
INLET TEE
SPLICE BOX
ORENCO #SB4
CONDUIT TO CONTROL PANEL
RHOMBUS PANEL ~FS
TIMER SETTINGS:
1.6 MIN ON / 4 HOURS OFF TO MEET: s::::::::~r:j
GAL / DAY = 600
GAL/ DOSE= 100
REDUNDANT OFF FLOAT
LIBERTY PUMP
#f'L150
PUMP ELEV. = 72.6
GAL / MIN = 62.3
HEAD (TOH) = 51.8
1150 GALLON PUMP CHAMBER
Scale: 1" = 2'
TESTING FOR WATER TIGHTNESS:
ALL TANKS MUST BE TESTED FOR WATER-TIGHTNESS AT THE
CONSTRUCTION SITE AND BE INSPECTED BY THE INSTALLER.
DESIGNER AND/OR THE LOCAL HEALTH OFFICER.
TO TEST FOR WATER TIGHTNESS:
1) SEAL THE EMPTY TANK
2) SEALALLACCESS OPENINGS, RISERS, INLET AND OUTLET
PIPES.
3) FILL THE EMPTY TANK WITH WATER UNTIL THE WATER IS 2
INCHES ABOVE THE RISER CONNECTION POINT.
4) LET THE TANK SIT FOR 1 HOUR.
5) IF THERE IS A MEASUREABLE DROP IN THE WATER ELEVATION·
REFILL THE TANK AND LET THE TANK STAND FOR ANOTHER
HOUR.
6) CHECK AROUND THE TANK TO LOOK FOR AREAS OF LEAKAGE.
7) THE TANK WILL PASS THE WATER-TIGHTNESS TEST WHEN THE
WATER LEVEL IS HELD FOR 1 HOUR WITH OUT ANY
MEASUREABLE LOSS.
8) IF REPAIRS HAVE TO BE MADE THE TANK WILL NEED TO BE
RETESTED AND INSPECTED BY THE INSTALLER, DESIGNER,
AND/OR LOCAL HEALTH OFFICER.
Environmental Design, LLC.
Septic Design • Wetlands • Mapping
901 L Street Centralia, Wa. 98531
(360) 219-3343
APPROVED
THURSTON COUNTY HEAL:
DATEcfU~//q_ BY /1, - r--
ALL TANKS MUST BE TESTED FOR
\./ATER TIGHTNESS DUE TO PROXIMITY
TO OPEN \./ATER,
EXISTING SEPTIC TANK SHALL BE
\ti ATER TESTED IF TO BE REUSED, IF
EXISTING TANK IS TO BE ABANDONED
THAN THE TANK SHALL BE
PUMPED BY AN APPROVED PUMPER,
HAVE LID REMOVED AND VOID FILLED
\./ITH SOIL OR GRAVEL AS PER
\t/AC 246-272A-0300, INST ALLER• PLEASE CALL
ENVIRONMENTAL DESIGN
REGARDING ANY QUESTIONS, CHANGES
OR CONCERNS,
PLEASE CALL BEFORE COVERING FOR
SCHEDULING OF A FINAL INSPECTION,
CUENT NAME: IHS (PIERCE)
MAILING ADDRESS: 4060 \t/HEA TON \,/ A Y, SUITE E BREMERTON, \t/A 98310
PHONE NUMBER: 360-792-1235
SITE ADDRESS: 10427 MULLEN RD SE, □L YMPIA
PARCEL NUMBER: 21831111300
PERMIT NUMBER:
DRAFTED BY: BJR JOB NUMBER: 2018-341
REVIEWED BY: BJR DATE: 07/31/2019
S-T-R: 31-18N-01E
PAGE 3 OF4
NATIVE GRADE
' . . ---xt-'f'U~~'§'")=r--~--6':.,;i~~"'t~>, ,'4, . <
~C;.-;~7,~)~'>.;:::,_,.,,,()6~-r)i. .... ,· .. ~-;,.,,...,.-.,.cc;":,, .. ~!ERA~- -- -s-:f..,S:..r 1-----"ILU===,:-_, -~~;&-~?~d,.S~:· .S:?_,g_,,S,,{,-l,..$f-~-~~, .. \-';,,J_-::- .J~- ...x .)s.:,',_1<'.-,it: ,:;d.CJ_';J-_ '57'>1....L~~ ,<.')(
7.
I•
DEPTH OF BACKALL
COVER SOIL
TYPE: LOAM
cu ms - g lRENCH DEPTH
I • DRAINROCK
3/4 - 2 1/2'
WASHED GRAVEL
CUYDS=B
DEPTH OF
3 • C-33 SAND
CU YOS ~ 27
VERTICAL
I • SEPARATION
1---------------------25••--------------------I
CLEAN-OUT/ACCESS
PORT DETAIL
I'
2.50'
1.25'
4 LATERALS AT 2:S fEET ts• SCHD 40 PVC
75 fEET H!llllf1JLD
IS' SCHD 40 PVC
TOR PORT
ORIFICES•
SIID ltB•
Q\JANTlY• 12
SPACING, 24•
LOCATIONi TOP
CLEANOUTS / MONITOR PORT
Environmental Design, LLC.
Septic Design • Wetlands• Mapping
901 LStreet Centralia, Wa. 98531
APP~~ED
THURSTON COUfHY HEALTH D,~TE c/ l:r/19 BY .iAM/
JJ~
LATERAL INLET ELEVATIONS
BED 1 (NORTHERN) = 99.2
BED 2 (MIDDLE) = 97.2
BED 3 (SOUTHERN) = 95.7
INSTALLER, PLEASE CALL
ENVIRONMENT AL DESIGN
REGARDING ANY GUESTJDNS, CHANGES
DR CONCERNS,
PLEASE CALL BEFORE COVERING FDR
SCHEDULING DF A FINAL INSPECTIDN,
WENT IWIE: !HS <PIERCE>
MAIUNG ADDRESS: 4060 WHEA TDN WAY, SUITE E
BREMERTON, WA 98310
PHONE NUMBER: 360-792-1235
SITT ADDRESS: 10427 MULLEN RD SE, DL YMPIA
PARCEL NUMBER:21831111300
PERMIT NUMBER:
DRAFTED BY: BJR JOB NUMB6!: 2018-341
REVIEWED BY: BJR DAlc:07/31/2019
5-T-R: 31-18N-01E
PAGE4 Of 4
NATIVE GRADE
7 I
VALVE BOX
ONG SWEEP ELBOW
ATERAL
CLEAN-OUT/ACCESS
PORT DETAIL
10'
DEPTH OF BACKALL
1 • COVER SOIL
TYPE: LOAM
CU VOS= g
DEPTH OF"
3 • C-33 SAND
CU YDS = 27
VERTICAL
1 • SEPARATION
l-------------------2s·------------------1
2.50'
1.25'
VALVES INSTALLED
AT EACH LATERAL
ORIFICES•
SIZE• 1/8'
QUANTIY• 12
SPACING• 24'
LOCA TION1 T□P
hl(_--------------23•----------------1
7,5 FEET MANIFOLD
1,S• SCHD 40 PVC
ONITDR PORT
CLEANOUTS I MONITOR PORT
En,,ironrr, SepLic .D. . enta/ Design ,_
'i!Srg,z • 'lfTeL/antfs • , Le.
C 9 0J L Street ~qPPing entra//a, Wa. 98531 .
(360) 219-3343
CUENT NAME: IHS (PIERCE)
MAIUNG ADDRESS: 4060 \./HEA
BREMERTON TO\./NA \./AY, SUITE E
' 98310
PHONE NUMBER· 360 ?
' - 92-1235
SITE ADDRESS: 10427 MUL
LEN RD SE 0
PARCEL NUMBER· 218311 ' l YMPI4
· 11300
PERMIT NUMBER: S-T-R: 3J-l8N -01t ec't..\on for a Pressurized System - Single Family Residence Pro1 ..
_ P\ERC'£
e l"',.sse-.nb1y S,ze 2._QQ inches art.Length "'185 feet sport. Pipe c,ass 40 2_00 inches nspo"-Line Siz.e None
,stnbu\ing Valve 1'ftodel
26.6 feet tlf\aX E.\e"8\io11 Litt 24 feet
\\l\anito\d Length
\11\anito\d Pipe Class
1.50 inches
Manito1d Pipe Size . 1"1urnbef" of Laterals per Cell 12
Latera1 Length 23 fe_et
Lateral Pipe Class
1.50 inches
Lateral Pipe-Size ,1/8 inches "i onficeSize Cl)
Orifice spacing 2 feet !:!:.
5 feet :c
Residual Head None inches
Q
Flow Meter I-
'A.dd-on' friction Losses 0 feet TS l3 ::c calculations u
;nimum Flow Rate per Orifice 0.43 gpm E ca 144 C
Number of Orifices per Zone >a
Total F\oW Rate per Zone 62,3 gpm Q
Number of Laterals per Zone _ 12 s % Flow Differential 1st/Last Orifice 0.2 % {!.
Transport Velocity 5.9 fps
Frictional Head Losses
LOSS through Discharge 7.8 feet
Loss in Transport 11.1 feet
LOSS through Valve 0,0 feet
Loss in Manifold 1.3 feet
Loss in Laterals 0.0 feet
Loss through Flowmeter 0.0 feet
'Add-on' Friction Losses 0.0 feet
Piee Volumes
Vol of Transport Line 32,2 gals
Vol of Manifold 2.5 gals Net Discharge (gpm) Vol of Laterals per Zone 29.2
Total Volume 63.9
Minimum Pump Requirements
Design Flow Rate Total Dynamic Head
.Orenco ·s,atem.
·lnco,porated
,CJ.,,,,,ging,J,,W,,_,,J,, U:i,,U o,,; If'..,,,,.,.,, 62,3 51.B gals gals
PumpData gpm feet
Legend
System Curve:-
Pump Curve:-
Pump Optimal Range
Operating PointQ
Design PointQ
. .. r- .;f
Dua/Sized Discharg_e
• • ' • ti • • •
1...---------'· · 1-1/211 or.2'_'
L 150-Series echnical Specifications
External Construction:
Pump Volute- Gray iron casting class 25 Pump Legs - Gray iron casting class 25 Motor Cover- Gray iron casting class 25 All casting shall be powder coated for corrosion resistance prior to assembly.
Motor:
Submersible 3450 RPM, oil filled and hennetically sealed.
Class B insulation rating. FL 150, 303 stainless steel rotor shaft. Thennally protected - single phase models. Three phase models shall have overloads incorporated into the control panel, properly sized for the horsepower and amperage of the pump.
Impeller:
Semi-open design. Cast iron construction.
Dual Shaft Seals:
FL 150-Series feature upper unitized silicon carbide, lower Viton double lip.
Models hp. Volts Phase Amps
FL152M-2 1-1/2 208-230 1 15
FL152A-2 1-1/2 208-230 1 15
FL153M-2 1-1/2 208/230 3 11.4
FL154M-2 1-1/2 440-480 3 5.7
FL155M-2 1-1/2 575 3 4.9
F.-~ ~ All fasteners shall be 300-series stair..
Power Cord: "'"" 25' length standard. Quick-disconnect design easy field replacement. (35' and 50' available o~
Level Control: ~ The pump shall be controlled by a wide angle mechanical float sealed in a PVC housing. The float shall have a series plug for manual by-pass operation.
A water-stop seal shall be incorporated into the cord entry to eliminate potential water wicking into the switch.
An adjustable clamp is provided for optional pipe mounting of the float.
Discharge:
2" FNPTwith 1-1/2" FNPT cast iron flange provided.
Maximum Fluid Temperature:
104° F (40° C) Continuous Duty 140°F (60° C) lntennittent
Discharge Automatic Cord Length Wgt.Lbs.
1-1/2" &2" No 25' 81 1-1/2" &2" Yes 25' 82 1-1/2" &2" No 25' 81 1-1/2" &2" No 25' 81 1-1/2" &2" No 25' 81
NOTE: 3-phase models require a control panel for automatic operation. See control panel literature for complete specifications on panels. 35' and 50' cord options available on 3-phase models. Add "-3" suffix or "-5" suffix to model number. Example: FL 153M-3 for 35' cord, FL 153M-5 for 50' cord.
60 hz Performance Cu,ve FL 150-Series
76 151 r--, Liters Per Minute 227 303 379
FL150
1-......., f--
' "'I\.. - ' 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 F10wlGPMI
181/4"
11 3/4"'
Certified
Specifications subject to change without notice.
Liberty Pumps • 7000 Apple Tree Avenue • Bergen, New York 14416 • Phone 800-543-2550 Fax (585) 494-1839 www.libertypumps.com Copyright© Liberty Pumps, Inc. 2011
All rights reserved. WT6770-R10/17