This set of documents includes construction plans and drawings for repairs to the National Grasslands Visitor Center in Wall, South Dakota, as well as the corresponding federal contract opportunity solicitation. The plans outline mechanical, crawlspace, and main floor repair work including replacing the HVAC unit, ductwork, insulation, vapor barrier, wall repairs, doors, and sump pump. The solicitation is from the US Department of Agriculture Forest Service for the 2023 National Grasslands Visitor Center Repairs requiring construction and repair services as detailed in the plans. The response due date and award date are not provided.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VISITOR CENTER
LOCATION
VICINITY MAP
TRAVEL DIRECTIONS:
SHEET OF
United States Department of Agriculture
Forest Service
NATIONAL GRASSLANDS VISITOR CENTER
Rapid City South Dakota Get on I-90 E from Theodore Roosevelt Expy 1. Head north on Mt Rushmore Rd toward St Joseph St 2. Use the 2nd from the left lane to turn left onto Omaha St 3. Turn right at the 1st cross street onto Theodore Roosevelt Expy 4. Keep left to stay on Theodore Roosevelt Expy 5. Keep right at the fork to continue on Exit 1B, follow signs for I-90 E/Sioux Falls and merge onto I-90 E Follow I-90 E. Take exit 109 from I-90 E 6. Merge onto I-90 E 7. Take exit 109 toward Wall/W 4th Ave Take Loop 90 to W 7th Ave in Wall 8. Turn left onto W 4th Ave 9. Turn right onto Loop 90 10. Turn left onto South Blvd 11. Turn left onto W 7th Ave National Grasslands Visitor Center 708 Main St, Wall, SD 57790 4 min (2.0 mi) 0.2 mi 0.2 mi 0.2 mi 1.0 mi 0.3 mi 43 min (52.0 mi) 51.7 mi 0.3 mi 3 min (1.1
mi) 0.3 mi 0.6 mi 128 ft 0.2 mi
WALL, SOUTH DAKOTA
RECOMMENDED BY:
APPROVED:
FOREST ENGINEER
DISTRICT RANGER
DATE
DATE
DIRECTOR OF ENGINEERING
DATE
FOREST SUPERVISOR DATE
RO FACILITIES PROGRAM MANAGER DATE
6/2 /23
:35
M
IC
HA
EL
W
EW
ER
KA
C :\U
SE
RS
\M
IC
HA
EL
W
EW
ER
KA
\B
OX
\M W
W
OR
K
SP
AC
E\
NF
G
VC
M
W \M
W N
GV
C
AR
CH
S
ET
.D W
G;
SOUTH DAKOTA
PENNINGTON COUNTY
R02-02
NEBRASKA NATIONAL FORESTS AND GRASSLANDS
WALL RANGER DISTRICT
INDEX OF SHEETS
SHE
ET
SHEET TITLE DATE
1 COVERSHEET 5/23/2023
2 MECHANICAL PLAN 5/23/2023
3 MAIN FLOOR REPAIR PLAN 5/23/2023
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
6/2 /23
:2
5 M
IC
HA
EL
W
EW
ER
KA C
:\U
SE
RS
\M
IC
HA
EL
W
EW
ER
KA
\B
OX
\E
P_
ON
ES
TO
PS
HO
P\
EP
P
RO
JE
CT
A
GR
EE
ME
NT
S\
NF
S\
R0 2-
\07
-N
EB
RA
SK
AN
FA
ND
NG
\C
LO
SE
D_
-E
NG
-0
7-
7\5
_W
OR
KI
NG
F
IL
ES
\F
IL
ES
\_0 2_
ME
CH
AN
IC
AL
PL
AN
.D
W G
R2
ROCKY MOUNTAIN REGION
NGVC - HVAC,
WALL, TRIM &
FINISH REPAIRS
NEBRASKA NATIONAL
FOREST & GRASSLANDS
WALL RANGER DISTRCT
MECHANICAL PLAN
04/26/2023
M.WEWERKA
D.KIMBALL
L.VAUGHAN
A-01 002 003
CRAWLSPACE MECHANICAL PLAN
20" X 20" UP
20" X 8"
OPEN TO
CRAWL
SPACE
20" X 20"
20" X 20"
20" X 20"
ACCESS HATCH
20" X 20" UP
20" X 20"
14" X 12"
20" X 14"
16" X 16"
14" X 12" 14" X 14"
30" X 6" UP
14" X 12" UP
GENERAL NOTES:
1. NEW DUCT SHALL NOT TOUCH GROUND IN ANY LOCATION. THIS MAY REQUIRE SOME
RE-GRADING OF CRAWLSPACE SOIL IN AREAS.
2. ANY ELECTRICAL JUNCTION BOXES IN CRAWLSPACE THAT DO NOT HAVE COVERS ON
THEM SHALL HAVE COVERS REINSTALLED.
3. GENERAL INTENT IS THE SYSTEM NEEDS TO GET BACK TO AN ORIGINAL FUNCTIONING
CONDITION. THIS MAY REQUIRE MINOR CONNECTIONS. IF ADDITIONAL DAMAGED
COMPONENTS NOT LISTED ARE DISCOVERED NOTIFY CO.
4. THERE IS EXISTING CONSTRUCTION DEBRIS THAT PAST CONTRACTORS HAVE LEFT IN
THE CRAWLSPACE. CONTRACTOR SHALL REMOVE ALL DEBRIS. THIS MAY INCLUDE BUT
NOT BE LIMITED TO PIPING, DUCT, AND INSULATION.
KEYED NOTES:
1 HEAT PUMP SHALL BE REMOVED AND REPLACED WITH WATERFURNACE
Model NBH072EL304PBVAN3B30SSD OR AN APPROVED EQUAL.
2 INLINE DUCT HEAT COILS SHALL BE REMOVED AND REPLACED WITH WARREN
TECHNOLOGIES CBK 24196-1, 10.80-20X20.0 HEAT COIL OR AN APPROVED EQUAL.
3 REPLACE INSULATED DUCT IN HATCHED AREAS. INTENT IS TO REPLACE ALL DUCT
THAT WATER REACHED. DUCTWORK THAT WATER DID NOT REACH DOES NOT NEED
TO BE REPLACED.
4 DISCONNECT AND CAP DUCT AS IT IMMEDIATELY ENTERS THE SPACE. REMOVE THE
REMAINING DUCT WORK TO WHERE IT EXHAUSTS INTO CRAWLSPACE. DISCONNECT
FAN THAT BLOWS INTO THIS DUCT ON MAIN LEVEL.
5 CLEAN SUMP OF SOIL AND REPLACE PUMP WITH
ZOELLER M98-
HP CAST IRON SUMP PUMP W/ VERTICAL FLOAT SWITCH
OR AN APPROVED EQUAL.
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text 4'
EXHIBITS RM
MULTIPUPOSE RM
PROJ. RM
MECH RM
MENS RM
WOMENS
STORAGE RM
MANAGER
OFFICE
OFFICE
OFFICE
VEST.
SALES STOR.
LOBBY
SALES
VESTIBULE
D F
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
6/2 /23
:2
5 M
IC
HA
EL
W
EW
ER
KA C
:\U
SE
RS
\M
IC
HA
EL
W
EW
ER
KA
\B
OX
\E
P_
ON
ES
TO
PS
HO
P\
EP
P
RO
JE
CT
A
GR
EE
ME
NT
S\
NF
S\
R0 2-
\07
-N
EB
RA
SK
AN
FA
ND
NG
\C
LO
SE
D_
-E
NG
-0
7-
7\5
_W
OR
KI
NG
F
IL
ES
\F
IL
ES
\_0 3_
MA
IN
FL
OO
RR
EP
AI
RP
LA
N.
DW
G
R2
ROCKY MOUNTAIN REGION
NGVC - HVAC,
WALL, TRIM &
FINISH REPAIRS
NEBRASKA NATIONAL
FORESTS &
GRASSLANDS
WALL RANGER DISTRCT
MAIN FLOOR REPAIR
PLAN
04/26/2023
M.WEWERKA
D.KIMBALL
L.VAUGHAN
A-02 003 003
MAIN FLOOR REPAIR PLAN
GENERAL NOTES:
1. CONTRACTOR IS RESPONSIBLE TO REPLACE ALL BASE BOARD AND TRIM BOARD THAT
HAS BEEN REMOVED.
2. CONTRACTOR SHALL REPLACE ANY INSULATION AND VAPOR BARRIER THAT HAS BEEN
REMOVED ON EXTERIOR WALLS. INSULATION SHALL BE POLY ISO FOAM WHEN IN
CONTACT WITH CONCRETE AND R-21 BATT INSULATION WHEN ABOVE CONCRETE
FOUNDATION.
3. CONTRACTOR SHALL ASSUME THAT ALL REPAIRS TO VAPOR VAPOR BARRIER AND
WALLS AVERAGES A 24-INCH REPAIR HEIGHT.
4. ALL GYPSUM WALL REPAIRS SHALL BE TAPED, MUDDED, AND PAINTED TO MATCH
EXISTING WALLS AS CLOSE AS POSSIBLE.
5. AREAS THAT ARE TILE OR VINYL FLOOR AND ARE NOT IN THE SCOPE OF NEW CARPET
LEGEND
WALLS NEEDING INSULATION, VAPOR BARRIER, AND GYPSUM REPLACED. IF
INSULATION IS PRESENT AND GOOD CONDITION IT MAY REMAIN IN PLACE.
CONTRACTOR AND COR SHALL INSPECT AND AGREE ON WHAT INSULATION
NEEDS REPLACED PRIOR TO COMMENCEMENT OF WORK.
WALLS NEEDING GYPSUM REPLACED.
AREAS WHERE ONLY WORK IS REPAIR, REROUTE AND INSULATION OF 2 IN
WATER LINE AND FRESH AIR INLET/OUTSIDE AIR LEAKS.
WALL SECTION, N.T.S.
SCORE AND CUT W/O
CUTTING VAPOR BARRIER
6 MIL VAPOR BARRIER
REMOVE THIS SECTION
AND TAPE NEW
VAPOR BARRIER TO OLD
NEW VAPOR
BARRIER
RIGID INSUL
*THIS PARTIAL WALL SECTION IS PROVIDE FOR ILLUSTRATION OF COMPONENTS*
CURRENT DEMO CUT
SCORE AND CUT W/O
CUTTING VAPOR BARRIER
6 MIL VAPOR BARRIER
REMOVE THIS SECTION
AND TAPE NEW
VAPOR BARRIER TO OLD
NEW VAPOR
BARRIER
RIGID INSUL
CURRENT DEMO CUT
NEW DOOR AND OPENING- 3-0 X 7-4 (VERIFY W/ COR) PREHUNG SC
WOOD VENEER AND FINISH DOOR AND JAMB TO MATCH EXISTING
OFFICE DOORS. (HARDWARE SAME AS NEW DOOR LEAF BELOW.)
NEW DOOR LEAF IN EXISTING OPENING-
3-0 x 7-4 (VERIFY IN FIELD) SC WD VENEER AND FINISH TO
MATCH EXISTING. HINGES: 3- EVERBILT 4IN X
RADIUS
STAINLESS STEEL COMMERCIAL GRADE W/BALL BEARING
HINGE. LOCKSET: GLOBAL DOOR CONTROL GLC SERIES
BRUSHED CHROME GRADE 3 COMMERCIAL PRIVACY DOOR
HANDLE WITH LOCK
12 MIL REINFORCED VAPOR BARRIER
IN CRAWL SPACE
(OPTION#4)
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text 4'
| 2023-06-27_R2 - SD_Nebr - National Grasslands Visitor Center_Theater repairs and Upgrades_ 100% - Plans Cover sheet |
| Sheets and Views |
| COVER |
| 2023-06-27_R2 - SD_Nebr - National Grasslands Visitor Center_Theater repairs and Upgrades_ 100% - MECHANICAL Rev 1 |
| Sheets and Views |
| A-01 |
| 2023-06-27_R2 - SD_Nebr - National Grasslands Visitor Center_Theater repairs and Upgrades_ 100% _MAINFLOORREPAIRPLAN REV1 |
| Sheets and Views |
| A-02 |
File details come from the government source that posted it. Updated .