US Department of Agriculture (USDA)
Statement of Work
Montrose Building Mezzanine and Storage Metal Cages
Contents Project General Information
1.0 Scope of Work
Contractor Requirements
2.0 Technical Requirements / Tasks
3.0 Place of Performance
4.0 Deliverables
Attachment
Project Montrose Building Mezzanine and Storage Metal Cages
General Information
1.0 Scope of Work
Provide and install a pre-engineered free-standing steel mezzanine with integrated storage wire cage system.
Contractor Requirements
2.0 Technical Requirements / Tasks
The project consists in providing all material and workmanship to construct a pre-engineered free-standing steel mezzanine with integrated storage wire cage system.
• Mezzanine system o Minimum system requirements:
Designed for 125 PSF Approximate deck dimensions: 28’W x 20’D Clear height 7’ Include a 6’ lift gate, stairs, landing and railing.
o See specification section 134400 and drawings for additional information.
• Wire mesh partitions for storage cages:
o Provide seven cages integrated to the mezzanine system.
o Minimum cages requirements:
Cage # Approx. Dimensions Door type Door Handles
1 7'W x 20'L x 7'H 3' Sliding Door Front key lock with back lever handle 2 7'W x 20'L x 7'H 3' Sliding Door Front key lock with back lever handle 3 7'W x 20'L x 7'H 3' Sliding Door Front key lock with back lever handle 4 7'W x 20'L x 7'H 3' Sliding Door Front key lock with back lever handle 5 7'W x 15'L x 7'H 3' Sliding Door Front key lock with back lever handle 6 7'W x 15'L x 7'H 3' Sliding Door Front key lock with back lever handle 7 7'W x 15'L x 7'H 3' Sliding Door Front key lock with back lever handle o See specification section 102213 and drawings for additional information.
3.0 Place of Performance
Location: This project is located at the Montrose Administrative site located at 1318 6400 Rd, Montrose
CO 81403.
Points of Contact for this project are: Daris M Matos - 970-964-8803.
Roads are accessible all year around under normal circurtances.
Project Scheduling: Work hours for this project are between 8:00 AM – 5:00 PM Monday through Friday.
4.0 Deliverables
• Provide project schedule and estimated material delivery time with proposal.
• Provide manufacture’s product data or brochure of mezzanine and wire mesh partitions with proposal.
• Provide description on how the two systems will be integrated (use manufacturers recommendations or general constructions standards)
• Provide submittals for mezzanine system and wire mesh partitions after contract award, before ordering or manufacturing any equipment.