This federal contract opportunity solicitation seeks construction services for renovating common area restrooms at the Lake City VA Medical Center in Lake City, Florida. The project number is 573A4-18-606, with a site visit scheduled for August 15, 2022 at 10:00 AM. Proposals are due by August 31, 2022 at 3:30 PM. This is a set-aside opportunity for Service-Disabled Veteran-Owned Small Businesses. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8. Attached drawings related to the renovation project are provided in the J.02 Attachment 02 - Drawings.pdf file.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FL 941-556-0757

VA PROJECT NO. 573A4-18-606

RENOVATE COMMON AREA RESTROOMS

LAKE CITY

VETERANS AFFAIRS MEDICAL CENTER

DESIGNED FOR: ARCHITECT:

LAKE CITY VA MEDICAL CENTER

619 S MARION AVE, LAKE CITY, FL 32025

PROJECT LOCATION MAP

VICINITY MAP

PROJECT LOCATION

VICINITY MAP

LAKE CITY, FL

NOT TO SCALE

VAMC

PROJECT

LOCATION

247 N

WWW.ABOVEGROUPINC.COM

COA/CA Lic. No. 31120

305 EAST DR. SUITE H, MELBOURNE, FLORIDA 32904

PH: 321.345.9026

ENGINEER:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbourne, Florida 32904

PH: 321.345.9026

C U s e rs

\c v a n m e te r.

A

B O

V E

G R

O U

P \D o c u m e n ts

\0

R e n o v a te C o m m o n A re a R e s tr o o m s E

P

R c v a n m e te rP N

X X

.r v t

/2

/2

:4

:5

P

M

GI-001

COVER SHEET RENOVATE COMMON

AREA RESTROOMS

LAKE CITY VAMC, FL

573A4-18-606

03/01/2021 KJD MRK

100% CONSTRUCTION

DOCUMENTS

KYLE J. DAVIS, P.E.

FL License #84275

DRAWING INDEX

Sheet Number Sheet Name

E-123 ELECTRICAL LEVEL 2 - BLDG 82

E-131 ELECTRICAL LEVEL 3 - BLDG 82

E-141 ELECTRICAL LEVEL 4 - BLDG 64

E-142 ELECTRICAL LEVEL 4 - BLDG 82

E-501 ELECTRICAL DETAILS

E-502 ELECTRICAL DETAILS & SCHEDULES

PL-001 PLUMBING LEGENDS, NOTES & SYMBOLS

PL-101A PLUMBING BASEMENT GRAVITY LEVEL - BLDG. 64

PL-101B PLUMBING BASEMENT PRESSURE LEVEL - BLDG. 64

PL-110 PLUMBING LEVEL 1 - BLDG. 19

PL-111 PLUMBING LEVEL 1 - BLDG. 38

PL-112 PLUMBING LEVEL 1 - BLDG. 62

PL-113 PLUMBING LEVEL 1 - BLDG. 64

PL-114 PLUMBING LEVEL 1 - BLDG. 64

PL-115A PLUMBING GRAVITY LEVEL 1 - BLDG. 64

PL-115B PLUMBING PRESSURE LEVEL 1 - BLDG. 64

PL-116A PLUMBING GRAVITY LEVEL 1 - BLDG. 64

PL-116B PLUMBING PRESSURE LEVEL 1 - BLDG. 64

PL-117A PLUMBING GRAVITY LEVEL 1 - BLDG. 64

PL-117B PLUMBING PRESSURE LEVEL 1 - BLDG. 64

PL-118A PLUMBING GRAVITY LEVEL 1 - BLDG. 64

PL-118B PLUMBING PRESSURE LEVEL 1 - BLDG. 64

PL-119 PLUMBING LEVEL 1 - BLDG. 82

PL-121A PLUMBING GRAVITY LEVEL 2 - BLDG. 64

PL-121B PLUMBING PRESSURE LEVEL 2 - BLDG. 64

PL-122 PLUMBING LEVEL 2 - BLDG. 64

PL-123 PLUMBING LEVEL 2 - BLDG. 82

PL-131 PLUMBING LEVEL 3 - BLDG. 82

PL-141 PLUMBING LEVEL 4 - BLDG. 64

PL-142 PLUMBING LEVEL 4 - BLDG. 64

PL-143 PLUMBING LEVEL 4 - BLDG. 82

PL-201 PLUMBING DETAILS

PL-301 PLUMBING ISOMETRICS

F-001 FIRE PROTECTION LEGENDS, NOTES & SYMBOLS

FA-101 FIRE PROTECTION BASEMENT LEVEL - BLDG. 64

FA-111 FIRE PROTECTION LEVEL 1 - BLDG. 19

FA-112 FIRE PROTECTION LEVEL 1 - BLDG. 38

FA-113 FIRE PROTECTION LEVEL 1 - BLDG. 62

FA-114 FIRE PROTECTION LEVEL 1 - BLDG. 64

FA-115 FIRE PROTECTION LEVEL 1 - BLDG. 64

FA-116 FIRE PROTECTION LEVEL 1 - BLDG. 64

FA-117 FIRE PROTECTION LEVEL 1 - BLDG. 64

FA-118 FIRE PROTECTION LEVEL 1 - BLDG. 82

FA-121 FIRE PROTECTION LEVEL 2 - BLDG. 64

FA-122 FIRE PROTECTION LEVEL 2 - BLDG. 64

FA-123 FIRE PROTECTION LEVEL 2 - BLDG. 82

FA-131 FIRE PROTECTION LEVEL 3 - BLDG. 82

FA-141 FIRE PROTECTION LEVEL 4 - BLDG. 64

FA-142 FIRE PROTECTION LEVEL 4 - BLDG. 82

DRAWING INDEX

Sheet Number Sheet Name

GI-001 COVER SHEET

GI-002 SYMBOLS AND ABBREVIATIONS

AS100 BASEMENT LOCATION PLANS

AS101 FIRST FLOOR LOCATION PLANS

AS102 SECOND, THIRD & FOURTH FLOOR LOCATION PLANS

AD101 ENLARGED RESTROOM DEMOLITION PLANS

AD102 ENLARGED RESTROOM DEMOLITION PLANS

AE101 ENLARGED NEW WORK RESTROOM FLOOR PLANS

AE102 ENLARGED NEW WORK RESTROOM FLOOR PLANS

AE111 ENLARGED RESTROOM REFLECTED CEILING PLANS

AE112 ENLARGED RESTROOM REFLECTED CEILING PLANS

AE201 INTERIOR ELEVATIONS

AE202 INTERIOR ELEVATIONS

AE203 INTERIOR ELEVATIONS

AE500 DOOR SCHEDULE/DETAILS & WALL TYPES

AE501 FINISH SCHEDULE & DETAILS

M-001 MECHANICAL LEGENDS, NOTES & SYMBOLS

MH-101 MECHANICAL BASEMENT LEVEL - BLDG. 64

MH-111 MECHANICAL LEVEL 1 - BLDG. 19

MH-112 MECHANICAL LEVEL 1 - BLDG. 38

MH-113 MECHANICAL LEVEL 1 - BLDG. 62

MH-114 MECHANICAL LEVEL 1 - BLDG. 64

MH-115 MECHANICAL LEVEL 1 - BLDG. 64

MH-116 MECHANICAL LEVEL 1 - BLDG. 64

MH-117 MECHANICAL LEVEL 1 - BLDG. 64

MH-118 MECHANICAL LEVEL 1 - BLDG. 64

MH-119 MECHANICAL LEVEL 1 - BLDG. 82

MH-121 MECHANICAL LEVEL 2 - BLDG. 64

MH-122 MECHANICAL LEVEL 2 - BLDG. 64

MH-123 MECHANICAL LEVEL 2 - BLDG. 82

MH-131 MECHANICAL LEVEL 3 - BLDG. 82

MH-141 MECHANICAL LEVEL 4 - BLDG. 64

MH-142 MECHANICAL LEVEL 4 - BLDG. 82

M-201 MECHANICAL DETAILS

M-301 MECHANICAL SCHEDULES

E-001 ELECTRICAL LEGENDS

E-002 ELECTRICAL GENERAL NOTES

E-003 ELECTRICAL GENERAL NOTES

E-004 ELECTRICAL GENERAL NOTES

E-101 ELECTRICAL BASEMENT LEVEL - BLDG. 64

E-111 ELECTRICAL LEVEL 1 - BLDG 19

E-112 ELECTRICAL LEVEL 1 - BLDG 38

E-113 ELECTRICAL LEVEL 1 - BLDG 62

E-114 ELECTRICAL LEVEL 1 - BLDG 64

E-115 ELECTRICAL LEVEL 1 - BLDG 64

E-116 ELECTRICAL LEVEL 1 - BLDG 64

E-117 ELECTRICAL LEVEL 1 - BLDG 64

E-118 ELECTRICAL LEVEL 1 - BLDG 82

E-121 ELECTRICAL LEVEL 2 - BLDG 64

E-122 ELECTRICAL LEVEL 2 - BLDG 64

Revisions: Date:

NOTE: REFER TO STRUCTURAL,

MECHANICAL, AND/OR ELECTRICAL

DRAWINGS FOR ABBREVIATIONS

SPECIFIC TO EACH DISCIPLINE.

AB ANCHOR BOLT, AUGER BORING

ABI ALTERNATE BID ITEM

AC ACOUSTIC AIR CONDITIONING,

ASPHALTIC CONCRETE

AD ACCESS DOOR

ADD ALT ADDITIVE ALTERNATE

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

ANOD ANODIZE

AP ACCESS PANEL

APC ACOUSTIC PANEL CEILING

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASB ASBESTOS

ASPH ASPHALT

AUTO AUTOMATIC

AWP ACOUSTIC WALL PANEL

BIT. CONC BITUMINOUS CONCRETE

BJ BAR JOIST

BLDG BUILDING

BLK BLOCK

BM BEAM, BENCHMARK

BOT BOTTOM

BRD BOARD

BRG BEARING

BS BOTTOM OF STEP

BSMT BASEMENT

BTWN BETWEEN

BW BOTTOM OF WALL

CAB CABINET

CAP CAPACITY

CC CENTER TO CENTER

CEM CEMENT

CFM CUBIC FEET PER MINUTE

CFS CUBIC FEET PER SECOND

CG CORNER GUARD

CI CAST IRON

CIR CIRCULATING

CJ CONSTRUCTION JOINT, CONTROL JOINT

CLG CEILING

CLO CLOSET

CLR CLEAR

CENTERLINE

CMU CONCRETE MASONRY UNITS

CMU G1 GLAZED CMU, ONE SIDE

CMU G2 GLAZED CMU, TWO SIDES

CO CLEANOUT

COL COLUMN

COMP'T COMPARTMENT

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUOUS

CPT CARPET

CS/CI CONTRACTOR SUPPLIED/ CONTRACTOR

INSTALLED

CS/OI CONTRACTOR SUPPLIED/OWNER

INSTALLED

CSK COUNTER SUNK

CT CERAMIC TILE

CTE CONNECT TO EXISTING

CTR CENTER

CUH CABINET UNIT HEATER

O DIAMETER

DF DRINKING FOUNTAIN

DFD DOOR FRAME DIMENSION

DH DOUBLE HUNG

DIA DIAMETER

DIM DIMENSION

DN DOWN

DTL DETAIL

DWG DRAWING

E EAST

EA EACH

EL, ELEV ELEVATION

ELEC ELECTRIC

EMERG EMERGENCY

EPS EXTRUDED POLYSTYRENE

EQ EQUAL

EQUIP EQUIPMENT

ETC ETCETERA

EW EACH WAY

EXIST EXISTING

EXP EXPANSION, EXPOSED

EXP JT EXPANSION JOINT

EXT EXTERIOR

FBO FURNISHED BY OTHERS

FCO FLOOR CLEAN-OUT

FD FLOOR DRAIN, FOOTING DRAIN

FE FIRE EXTINGUISHER

FF FINISH FLOOR

FFE FINISHED FLOOR ELEVATION

FG FINISH GRADE, FIBERGLASS

FHC FIRE HOSE CABINET

FIG FIGURE

FIN FINISH

FO FUEL OIL

FOF FACE OF FOUNDATION

FOR FUEL OIL RETURN

FOS FACE OF STUD, FUEL OIL SUPPLY

FOUND FOUNDATION

FP FIREPROOF

FR FRAME, FIRE RESISTANT

FS FLOOR SINK

FT FOOT, FEET, FINNED TUBE

FTG FOOTING

FWP FABRIC WALL PANEL

GA GAUGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GF/GI GOVT. FURNISHED/GOVT. INSTALLED

GF/CI GOVT. FURNISHED/CONTRACTOR

INSTALLED

GI GALVANIZED IRON

GOV'T GOVERNMENT

GPM GALLONS PER MINUTE

GR GRADE

GRAN GRANULAR

GRD GROUND

GWB GYPSUM WALLBOARD

GYP GYPSUM

HGT HEIGHT

H&V HEATING AND VENTILATING

HB HOSE BIB

HC HANDICAPPED

HCWD HOLLOW CORE WOOD DOOR

HDC HANDICAPPED

HDW HARDWARE

HDWD HARDWOOD

HM HOLLOW METAL

HVAC HEATING, VENTILATING, AND AIR

CONDITIONING

IN INSIDE DIAMETER

INCL INCLUSIVE

INFO INFORMATION

INSUL INSLUATION, INSULATED

INT INTERIOR

IWP IMPACT RESISTANT WALL PROTECTION

JAN JANITOR CLOSET

JCT JUNCTION

KV KILOVOLT

KW KILOWATT

LAB LABORATORY

LAV LAVATORY

LBS POUNDS

LF LINEAR FEET

LFC LINOLEUM FLOOR COVERING

LGR LEDGER

LP LOW POINT

LR LIVING ROOM

LT LIGHT

LWC LIGHT WEIGHT CONCRETE

MACH MACHINE

MANUF MANUFACTURER

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MB MARKER BOARD

MC MEDICINE CABINET

MCB METAL CORNER BEAD

MECH MECHANICAL

MIN MINIMUM

MIR MIRROR

MISC MISCELLANEOUS

MM MILLIMETER

MO MASONRY OPENING

MR MOISTURE RESISTANT

MS METAL STRIP

MTD MOUNTED

MTL METAL

N NORTH

N.I.C. NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OA OVER ALL

OB GL OBSCURE GLASS

OC ON CENTER

OD OUTSIDE DIAMETER

OPNG OPENING

OPP OPPOSITE

OS/CI OWNER SUPPLIED/CONTRACTOR

INSTALLED

OS/OI OWNER SUPPLIED/OWNER INSTALLED

OVHD, OH OVERHEAD

P-1 PLUMBING FIXTURE TYPE

PART PARTITION

PL PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLAST PLASTIC

PLYWD PLYWOOD

PNL PANEL

PNTD PAINTED

POL POLISHED

PRELIM PRELIMINARY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, POINT, PRESSURE TREATED

PT DISP PAPER TOWEL DISPENSER

PVC POLY VINYL CHLORIDE

PVMT PAVEMENT

QT QUARRY TILE

R RADIUS, RISER

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN, ROAD

RECEP RECEPTACLE

REF REFRIGERATOR

REINF REINFORCEMENT

REQ'D REQUIRED

REV REVISION

RF RESINOUS FLOOR

RL RAIN LEADER

RM ROOM

RO ROUGH OPENING

RS RESILIENT STAIR ACCESSORY

RT RUBBER TILE

S SOUTH

S DISP SOAP DISPENSER

S&V STAIN AND VARNISH

SCONC SEALED CONCRETE

SCWD SOLID CORE WOOD DOOR

SCH SCHEDULE

SCR SUPPLY CEILING REGISTER

SECT SECTION

SF SQUARE FEET

SH SINGLE HUNG

SHT SHEET

SIM SIMILAR

SL SLOPE

SPECS SPECIFICATIONS

SQ SQUARE

SQ FT SQUARE FEET

SS SERVICE SINK, SANITARY

SEWER, STAINLESS STEEL

SSURFACE SOLID SURFACE

ST STREET

STA STATION

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUP SUPPORT

SUSP SUSPEND

SV SHEET VINYL

SYM SYMMETRICAL

T TOP, TANGENT, THERMOMETER

TB TACK BOARD

TBA TOILET BATH ACCESSORIES

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

T.O.C. TOP OF CONCRETE

T.O.M. TOP OF MASONRY

T.O.S. TOP OF STEEL

T.O.W. TOP OF WALL

TEL TELEPHONE

TEMP TEMPERATURE, TEMPORARY

TERM TERMINAL

THK THICK

THRU THROUGH

TP TOILET PARTITION

TPH TOILET PAPER HOLDER

TRAN TRANSOM

TS TOP OF STEP, TOP OF SILL

TV TELEVISION

TYP TYPICAL

TYPE "X" UL APPROVED GWB

U&D UP AND DOWN

UC UNDERCUT

UV UNIT VENTILATOR

VB VAPOR BARRIER

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VTR VENT THROUGH ROOF

W WEST

WAIN WAINSCOT

WB RESILIENT WALL BASE

WC WALL COVERING

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WIDTH, WINDOW DIMENSION,

WOOD

WGL WIRE GLASS

WP WATERPROOF, WEATHERPROOF

WS WEATHERSTRIPPING

WT WEIGHT

WW WELDED WIRE FABRIC

DRAWING REFERENCED

FROM ANOTHER SHEET

DRAWING TITLE

DRAWING

INDICATOR

SCALE OF

DRAWING

F

E

D

1 2 3

1 View Name

1/8" = 1'-0" R101

A1

SCALE: 1/8" = 1'-0"

4' 8'0 16'

B3

D

C

B

A

SHEET NUMBER

DETAIL IS DRAWN ON

ROOM NAME

ROOM NUMBER

BREAK LINE

GRAPHIC SCALE

REVISION NUMBER

REVISION CLOUD

ELEVATION MARKER - SECTION

ELEVATION MARKER - PLAN

DOOR NUMBER REFERENCE

WINDOW TYPE REFERENCE

WALL TYPE REFERENCE

COLUMN GRID REFERENCE

SHEET NUMBER ELEVATION

IS DRAWN ON

INTERIOR ELEVATION

REFERENCE

BUILDING / WALL

SECTION NUMBER

SHEET NUMBER BUILDING /

WALL SECTION IS DRAWN ON

BUILDING ELEVATION

NUMBER

SHEET NUMBER

ELEVATION IS DRAWN ON

DETAIL NUMBER

SYMBOLS

STEEL & OTHER METAL PATTERN

CONCRETE BLOCK PATTERN

STONE CUT PATTERN

TERRA COTTA

CARPET AND PAD PATTERN

TILE, ACOUSTICAL

CEILING PATTERN

WOOD FLOORING PATTERN

BRICK PATTERN, GLAZED

SAND CLAY GRAVEL PATTERN

BRICK PATTERN

EROSION AND SEDIMENTATION

CONTROL, FILTRATION BED

PATTERN

EARTHWORK GRAVEL

PATTERN, POROUS FILL

EARTHWORK ROCK PATTERN

EARTHWORK PATTERN,

COMPACTED FILL PATTERN

RIPRAP PATTERN

SAND PATTERN

GLASS ELEVATION PATTERN

GYPSUM BOARD FINISH PATTERN

SEALANT AND BACKER ROD

INSULATION, RIGID

BOARD PATTERN

INSULATION, LOOSE

FILL PATTERN

WOOD FINISH PATTERN

PARTICLE BOARD PATTERN

ORIENTED STRAND BOARD PATTERN

WOOD, GLUED-LAMINATED PATTERN

WOOD FRAMING,

CONTINUOUS PATTERN

WOOD BLOCKING OR SHIM PATTERN

HATCH PATTERNS

EARTH, UNDISTURBED

PATTERN

EARTH, CRUSHED ROCK

GRAVEL PATTERN

EARTH, CRUSHED ROCK

GRAVEL PATTERN

PLYWOOD PATTERN

10 '-0"

Room name

B

M2

A1

AE101

A101

SIM

A1

AE101

CONCRETE POURED IN

PLACE, PRECAST

ALUMINUM PATTERN

ASPHALT SHINGLE PATTERN

KEYNOTE REFERENCE

BUILDING STRUCTURE

FIRESAFING INSUL

UL 1479/ASTM E814

FIRESTOP SEALANT

UL 723/ASTM E119

GYPSUM

WALLBOARD

PTN TYPE

VARIES - SEE

PLAN

PARTITION TOP ASSEMBLY

1HR / 2HR FIRE - RATED

ANSI\UL #263 DESIGN HWS001

PT-1

BUILDING STRUCTURE

FIRESAFING INSUL

UL 1479/ASTM E814

FIRESTOP SEALANT

UL 723/ASTM E119

(ONE SIDE ONLY)

GYPSUM

WALLBOARD

PTN TYPE

VARIES - SEE

PLAN

PARTITION TOP ASSEMBLY

30 MIN FIRE - RATED PT-1A

HC OCCUPANCY CORRIDOR

2 HOUR RATED FIRE & SMOKE PARTITION

2 HOUR RATED PARTITION

1 HOUR RATED PARTITION

LINETYPES

SMOKE ZONE BARRIER

SMOKE RESISTIVE ENCLOSURE

EXISTING LIFE SAFETY INFORMATION:

NEW WORK TO BE PERFORM IN THIS PROJECT WILL NOT HAVE AN

AFFECT ON THE EXISTING LIFE SAFETY ARRANGEMENT. NO

CHANGES TO TRAVEL PATHS OR RATED PARTITIONS ARE

ANTICIPATED.

EXISTING PARTITION LIFE SAFETY DESIGNATION SHOWN ON THESE

DRAWINGS HAS BEEN TRANSLATED FROM EXISTING FACILITY LIFE

SAFETY DRAWINGS PROVIDED BY THE VA.

PLEASE ALERT A/E IF DISCREPANCIES ARE FOUND IN THE FIELD.

ALL PENETRATIONS IS RATED PARTITIONS ARE TO BE PROVIDED

WITH APPROPRIATE FIRESTOPPING - SEE DETAILS BELOW.

ANNULAR FIRESTOPPING

THINKNESS REQUIREMENTS

TO COMPLY WITH

ANSI/UL263-DESIGN No.

FC7009 OR APPROVED

EQUIVALENT

STEEL FLANGES

DUCTWORK

ASSEMBLY VARIES SEE

ARCHITECTURAL PLANS &

DETAILS

FIRESEAL ON

FIRESAFING SYSTEM

WALL PENETRATION FIRESTOP

1HR / 2HR FIRE - RATED (FD N-REQD)

ANSI\UL #263 WL7009

WP- 1

DUCTWORK

ANNULAR FIRESTOPPING

THINKNESS

REQUIREMENTS TO

COMPLY WITH ANSI/UL263-

DESIGN No. WL1049 OR

APPROVED EQUIVALENT

ASSEMBLY VARIES SEE

ARCHITECTURAL PLANS &

DETAILS

METALLIC PIPE 6"

DIA OR SMALLER

FIRESEAL ON

FIRESAFING SYSTEMS

SEE SPECS

WALL PENETRATION FIRESTOP

1HR / 2HR FIRE - RATED

ANSI\UL #263 DESIGN WL1049

WP- 3

METALLIC PIPE 6" DIA

OR SMALLER

NOMINAL 3/8" FIRESTOP

SYSTEM (ANSI/UL 263 -

DESIGN CAJ-2124)

ASSEMBLY VARIES SEE

ARCHITECTURAL PLANS &

DETAILS

CLIP AND STEEL

ANCHOR

WALL PENETRATION FIRESTOP

2HR/3HR FIRE BARRIER

ANSI\UL #263 DESIGN DS1076

WP- 4

PLASTIC PIPE

FIRESTOP WRAP

STRIP SYSTEM

SCREW AND CLAMP

ELECTRICAL CONDUIT /

CABLE (SINGLE OR BUNDLE

UP TO 4 1/2" DIA)

ASSEMBLY VARIES SEE

ARCHITECTURAL PLANS &

DETAILS

ANNULAR FIRESTOPPING

THICKNESS REQUIREMENTS

TO COMPLY WITH

ANSI/UL263 DESIGN No.

WL3076 OR APPROVED

EQUIVALENT

WALL PENETRATION FIRESTOP

1HR / 2HR FIRE - RATED

ANSI\UL #263 DESIGN WL3076

WP- 5

NOTE:

ANNULUS RANGING

FROM POINT

CONTACT TO 2"

MAXIMUM

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :4 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

GI-002

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC04/30/2021

100% CONSTRUCTION

DOCUMENTS

SYMBOLS AND ABBREVIATIONS

FULLY SPRINKLERED

ARCHITECTURAL ABBREVIATIONS DRAWING AREA

ARCHITECTURAL SYMBOLS

1 1/2" = 1'-0"

1 PT-1 PARTITION TOP FIRESTOP

1 1/2" = 1'-0"

2 PT-1A PARTITION TOP FIRESTOP

1 1/2" = 1'-0"

3 WP-1 WALL PENETRATION FIRESTOP

1 1/2" = 1'-0"

4 WP-3 WALL PENETRATION FIRESTOP

1 1/2" = 1'-0"

6 WP-4 WALL PENETRATION FIRESTOP

1 1/2" = 1'-0"

5 WP-5 WALL PENETRATION FIRESTOP

ARCHITECTURAL SHEET LIST

Sheet Number Sheet Name

GI-002 SYMBOLS AND ABBREVIATIONS

AS100 BASEMENT LOCATION PLANS

AS101 FIRST FLOOR LOCATION PLANS

AS102 SECOND, THIRD & FORTH FLOOR LOCATION PLANS

AD101 ENLARGED RESTROOM DEMOLITION PLANS

AD102 ENLARGED RESTROOM DEMOLITION PLANS

AE101 ENLARGED NEW WORK RESTROOM FLOOR PLANS

AE102 ENLARGED NEW WORK RESTROOM FLOOR PLANS

AE111 ENLARGED RESTROOM REFLECTED CEILING PLANS

AE112 ENLARGED RESTROOM REFLECTED CEILING PLANS

AE201 INTERIOR ELEVATIONS

AE202 INTERIOR ELEVATIONS

AE203 INTERIOR ELEVATIONS

AE500 DOOR SCHEDULE / DETAILS & WALL TYPES

AE501 FINSH SCHEDULE & DETAILS

BLDG. 82

BLDG. 64

BLDG. 64-2

BLDG. 64

B64-2 - CB4

B64-2 - CB5

B L D G

B L D G

B82 - 168

AD101

Sim

AD101

Sim

D1/AD101 - DEMOLITION PLAN

D1/AE101 - NEW WORK PLAN

D1/AE111 - REFLECTED

CEILING PLAN

B7/AD101 - DEMOLITION PLAN

B7/AE101 - NEW WORK PLAN

B7/AE111 - REFLECTED

CEILING PLAN

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :3 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AS100

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

BASEMENT LOCATION PLANS

FULLY SPRINKLERED

3/64" = 1'-0"

1 BASEMENT LEVEL - BUILDING 64 & 82

D N

D N

R A M P

R A M P

U P

D N

S M O K

IN

G

S H E L T E R

U P

B L D G

F E C

D N

R A M P

D N

R A M P

D N

B L D G

B L D G

BLDG. 64-2

BLDG. 64

BLDG. 82

BLDG. 64

B L D G

B L D G

B-64 - A137

B-38 - 123

B-64-2 - C144

B-64-2 - C138J

B-19 - 113

B-82 - 168

B-64-2 - C136

B-64 - A127, A129 & A130

B-64-2 - C132

B5/AD102 - DEMOLITION PLAN

B5/AE102 - NEW WORK PLAN

B5/AE112 - REFLECTED

CEILING PLAN

AD102

Sim

AD102

Sim

D7/AD102 - DEMOLITION PLAN

D7/AE102 - NEW WORK PLAN

D7/AE112 - REFLECTED

CEILING PLAN

AD102

Sim

F7/AD102 - DEMOLITION PLAN

F7/AE102 - NEW WORK PLAN

F7/AE112 - REFLECTED

CEILING PLAN

AD101

Sim

F7/AD102 - DEMOLITION PLAN

F7/AE102 - NEW WORK PLAN

F7/AE112 - REFLECTED

CEILING PLAN

AD101

Sim

D3/AD101 - DEMOLITION PLAN

D3/AE101 - NEW WORK PLAN

D3/AE111 - REFLECTED

CEILING PLAN

AD101

Sim

F7/AD101 - DEMOLITION PLAN

F7/AE101 - NEW WORK PLAN

F7/AE111 - REFLECTED

CEILING PLAN

AD102

Sim

F5/AD102 - DEMOLITION PLAN

F5/AE102 - NEW WORK PLAN

F5/AE112 - REFLECTED

CEILING PLAN

AD102

Sim

B7/AD102 - DEMOLITION PLAN

B7/AE102 - NEW WORK PLAN

B7/AE112 - REFLECTED

CEILING PLAN

AD101

Sim

B7/AD101 - DEMOLITION PLAN

B7/AE101 - NEW WORK PLAN

B7/AE111 - REFLECTED

CEILING PLAN

B-62 - 113 & 113A

AD101

Sim

F5/AD101 - DEMOLITION PLAN

F5/AE101 - NEW WORK PLAN

F5/AE111 - REFLECTED

CEILING PLAN

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :4 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AS101

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

FIRST FLOOR LOCATION PLANS

FULLY SPRINKLERED

3/64" = 1'-0"

2 1ST FLOOR - BUILDING 19, 38, 64, 64-2, 82

3/64" = 1'-0"

1 1ST FLOOR - BUILDING 62

B-64 - B204

B-64 - C-237

B-82 - 366

BLDG. 82

BLDG. 64

AD102

Sim

D5/AD102 - DEMOLITION PLAN

D5/AE102 - NEW WORK PLAN

D5/AE112 - REFLECTED

CEILING PLAN

AD101

Sim

B3/AD101 - DEMOLITION PLAN

B3/AE101 - NEW WORK PLAN

B3/AE111 - REFLECTED

CEILING PLAN

AD101

Sim

D7/AD101 - DEMOLITION PLAN

D7/AE101 - NEW WORK PLAN

D7/AE111 - REFLECTED

CEILING PLAN

BLDG. 82

BLDG. 64

AD101

Sim

B1/AD101 - DEMOLITION PLAN

B1/AE101 - NEW WORK PLAN

B1/AE111 - REFLECTED

CEILING PLAN

B-82 - 481

B-64 - A401A B-64 - A443

AD101

Sim

F3/AD101 - DEMOLITION PLAN

F3/AE101 - NEW WORK PLAN

F3/AE111 - REFLECTED

CEILING PLAN

AD101

Sim

F1/AD101 - DEMOLITION PLAN

F1/AE101 - NEW WORK PLAN

F1/AE111 - REFLECTED

CEILING PLAN

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :4 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AS102

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

SECOND, THIRD & FORTH FLOOR

LOCATION PLANS

FULLY SPRINKLERED

3/64" = 1'-0"

3 2ND FLOOR - BUILDINGS 64 & 82

3/64" = 1'-0"

1 3RD FLOOR - BUILDING 82

3/64" = 1'-0"

2 4TH FLOOR - BUILDINGS 64

B

A

C-234

C-224

MEN'S

RESTROOM

B38-123

R4 R4

R4

R3

R3

R4R4

R1

R5

R2

R2

(MIN.CLEAR)

5' - 0"

R10

R9

R8

R8

R4

R4

R3

R4

R7

B62-113

MEN'S

RESTROOM

R4 R4

R4

R3

R1

R1

R2

R2

(MIN. CLEAR)

5' - 0"

R9

UNISEX

RESTROOM

B64-A401A

R4

R4

R8R8

R9

WAITING

B64-A401

R1 R2

R14

(5 '-0 M

IN

C L E A R

R4R4

R11

R10

B64-A443

RESTROOM

B64-A444

B64-A444B

RESTROOM

R9

R9

WAITING

B64-A444A

R8

R8

R14

R9

R1

R1

(5'-0" MIN. CLEAR)

6' - 0"

MEN'S

RESTROOM

B64-C237

R4 R4

R2

R5

R3

R4

R1

R9

R7

R4

R4 R4 R4

R2

(M

IN

C L E A R

TOILET

B64-2-138J

R4

R4

R1

R2

R4

R4 R1

R2

R9

R8 R7 R7

B64-2-138L

STAFF

(M

IN

C L E A R

B64-2-138M

HAC

R7

R1

R9

R4

R8

R9

RESTROOM

B64-2-C144

R4

R4

R1

R2

CORRIDOR

B64A-C1-19

(5'-0" MIN. CLEAR)

5' - 9" R9

MEN

B64-2-CB4

WOMEN

B64-2-CB5

R4

R3

R4

R4

R3

R10

R1

R2

R4

R4

R1

R2

R8 R8

(5'-0" MIN. CLEAR)

5' - 6"

(5'-0" MIN. CLEAR)

5' - 6"

R9

R9

R4 R4 R4

R1

MEN'S

RESTROOM

B82-258

R8

WOMEN

B82-259

R2

(5'-0" MIN. CLEAR)

5' - 6"

R9

R4

R4 R4

R1

MEN'S

RESTROOM

B82-366

WOMEN

B82-368

R8

R2

(5'-0" MIN. CLEAR)

5' - 6"

R9 R1

R4

R4MEN'S

RESTROOM

B82-481

WOMEN

B82-482

R8

R2

(5'-0" MIN. CLEAR)

5' - 6"

R9

GENERAL DEMOLITION NOTES:

1. GENERAL CONTRACTOR (GC) SHALL FIELD VERIFY & REPORT EXISTING

CONDITIONS AND DIMENSIONS PRIOR TO REMOVALS. IF DISCREPANCIES ARE FOUND.

GC TO NOTIFY ARCHITECT FOR CLARIFICATION BEFORE COMMENCING WITH THE

WORK.

2. GC AND SUBCONTRACTORS (SC) FOR EACH TRADE ARE ADVISED THAT

INFORMATION PERTINENT TO THEIR WORK MAY BE INDICATED OR DESCRIBED IN

OTHER PORTIONS OF THE CONTRACT DOCUMENTS.

3. REFER TO SPECIFIC DRAWINGS FOR PLUMBING, HVAC AND ELECTRICAL

REMOVALS WORK.

4. GC AND SC ARE RESPONSIBLE FOR PROVIDING ALL REMOVALS AND PATCHING

REQUIRED TO COMPLETE THEIR WORK IN ACCORDANCE WITH THE DESIGN INTENT.

5. THESE REMOVALS DRAWINGS HAVE BEEN PREPARED BASED UPON EXISTING

CONSTRUCTION DOCUMENT DRAWINGS AND FIELD OBSERVATIONS. THE EXACT

LOCATION OF THE BUILDING STRUCTURAL ELEMENTS (COLUMNS, BEAMS, LOAD

BEARING WALLS, ETC.) MAY BE DIFFERENT IN THE FIELD THAN WHAT IS INDICATED OR

ASSUMED ON THESE DRAWINGS. GC SHALL FIELD VERIFY THE LOCATION OF ALL

BUILDING STRUCTURAL ELEMENTS. ALL BUILDING STRUCTURAL ELEMENTS SHALL

REMAIN UNLESS INDICATED TO BE REMOVED ON THE STRUCTURAL DRAWINGS. ANY

BUILDING STRUCTURAL ELEMENT INDICATED AS BEING REMOVED ON THIS DRAWING

SHALL BE CONFIRMED WITH THE ARCHITECT PRIOR TO COMMENCING REMOVALS

6. GC SHALL PROTECT, REPLACE OR REPAIR ANY EXISTING CONSTRUCTION

SCHEDULED TO REMAIN WHICH IS DAMAGED DURING REMOVALS

7. GC SHALL PROVIDE REQUIRED SHORING OR TEMPORARY BRACING DURING

REMOVALS

8. REMOVE EXISTING CEILINGS AND SUPPORTS WHERE NEW CEILINGS ARE

SCHEDULED IN THE ROOM FINISH SCHEDULE.

9. REMOVE PARTITIONS, FIXTURES, TOILET ACCESSORIES, SHELVING, CABINETRY

AND ALL MISCELLANEOUS ITEMS SHOWN WITH DASHED LINES.

10. PATCH ALL FLOORS, WALLS, BASE AND CEILINGS WHERE PARTITIONS OR

MISCELLANEOUS ITEMS ARE REMOVED.

11. REMOVE DOORS, FRAMES AND SIDELIGHTS SHOWN WITH DASHED LINES,

UNLESS OTHERWISE NOTED.

12. REMOVE TOILET PARTITIONS AND GRAB BARS SHOWN WITH DASHED LINES.

REPAIR EXISTING CONSTRUCTION SCHEDULED TO REMAIN.

13. REMOVE EXISTING FLOR AND WALL TILE WHERE NEW IS SCHEDULED IN THE

ROOM FINISH SCHEDULE AND PREPARE EXISTING FLOOR AND WALL SURFACES TO

RECEIVE NEW FINISHES.

14. CONTRACTOR SHALL VERIFY WITH THE OWNER THOSE REMOVED ITEMS TO BE

TURNED OVER TO THE OWNER.

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

NEW PARTITION (SEE PARTITION

TYPES FOR ADDITIONAL INFO.)

TEMPORARY PARTITION

NOTES:

TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION

REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY

PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS

AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.

PARTITION LEGEND:

MEN'S

RESTROOM

B82-168

R4 R4 R4

R1

WOMEN

B82-167

R8

R2

(5'-0" MIN. CLEAR)

5' - 6"

R9

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :1 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AD101

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

ENLARGED RESTROOM

DEMOLITION PLANS

FULLY SPRINKLERED

1/4" = 1'-0" AS101

3 DEMOLITION PLAN B38 - RM 123

1/4" = 1'-0" AS101

6 DEMOLITION PLAN B62 - RM 113

1/4" = 1'-0" AS102

12 DEMOLITION PLAN B64 - RM A401A

1/4" = 1'-0" AS102

9 DEMOLITION PLAN B64 - RM A444

1/4" = 1'-0" AS102

2 DEMOLITION PLAN B64 - RM C237

1/4" = 1'-0" AS101

5 DEMOLITION PLAN B64-2 - RM C138J, C138L & C138M

1/4" = 1'-0" AS101

8 DEMOLITION PLAN B64-2 - RM C144

1/4" = 1'-0" AS100

11 DEMOLITION PLAN B64-2 - RMS CB4 & CB5

1/4" = 1'-0"

4 DEMOLITION PLAN B82 - RM 258

1/4" = 1'-0" AS102

7 DEMOLITION PLAN B82 - RM 366

1/4" = 1'-0" AS102

10 DEMOLITION PLAN B82 - RM 481

R1 REMOVE ALL FINISHES, INCLUDING TILE FLOORING, TILE WAINSCOT, ACT OR

GYPSUM CEILINGS. SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION.

R2 REMOVE ALL EXISTING TOILET ACCESSORIES.

R3 REMOVE ALL EXISTING TOILET PARTITIONS.

R4 REMOVE EXISTING PLUMBING FIXTURES - SEE PLUMBING DRAWINGS FOR

ADDITIONAL INFORMATION.

R5 REMOVE EXISTING CUBICLE CURTAIN AND TRACK.

R7 SLECTIVLY REMOVE PORTION OF EXISTING WALL TO PREPARE FOR

INSTATLLATION OF NEW DOOR AND FRAME - REFER TO NEW WORK PLANS FOR

ADDITIONAL INFORMATION.

R8 REMOVE EXISTING WALL SHOWN DASHED.

R9 REMOVE EXISTING DOOR AND FRAME.

R10 REMOVE EXISTING CASEWORK SHOWN DASHED.

R11 REMOVE EXISTING SHOWER FIXTURES AND ACCESSORIES.

R14 APPROXIMATE EXTENTS OF EXISTING VCT FLOORING OUTSIDE OF RESTROOM

REQUIRED TO BE DEMOLISHED TO EXPAND RESTROOM FOOTPRINT - REFER TO

NEW WORK PLANS FOR ADDITIONAL INFORMATION.

KEYNOTES

1/4" = 1'-0" AS100

1 DEMOLITION PLAN B82 - RM 168

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

NEW PARTITION (SEE PARTITION

TYPES FOR ADDITIONAL INFO.)

TEMPORARY PARTITION

NOTES:

TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION

REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY

PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS

AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.

PARTITION LEGEND:

GENERAL DEMOLITION NOTES:

1. GENERAL CONTRACTOR (GC) SHALL FIELD VERIFY & REPORT EXISTING

CONDITIONS AND DIMENSIONS PRIOR TO REMOVALS. IF DISCREPANCIES ARE FOUND.

GC TO NOTIFY ARCHITECT FOR CLARIFICATION BEFORE COMMENCING WITH THE

WORK.

2. GC AND SUBCONTRACTORS (SC) FOR EACH TRADE ARE ADVISED THAT

INFORMATION PERTINENT TO THEIR WORK MAY BE INDICATED OR DESCRIBED IN

OTHER PORTIONS OF THE CONTRACT DOCUMENTS.

3. REFER TO SPECIFIC DRAWINGS FOR PLUMBING, HVAC AND ELECTRICAL

REMOVALS WORK.

4. GC AND SC ARE RESPONSIBLE FOR PROVIDING ALL REMOVALS AND PATCHING

REQUIRED TO COMPLETE THEIR WORK IN ACCORDANCE WITH THE DESIGN INTENT.

5. THESE REMOVALS DRAWINGS HAVE BEEN PREPARED BASED UPON EXISTING

CONSTRUCTION DOCUMENT DRAWINGS AND FIELD OBSERVATIONS. THE EXACT

LOCATION OF THE BUILDING STRUCTURAL ELEMENTS (COLUMNS, BEAMS, LOAD

BEARING WALLS, ETC.) MAY BE DIFFERENT IN THE FIELD THAN WHAT IS INDICATED OR

ASSUMED ON THESE DRAWINGS. GC SHALL FIELD VERIFY THE LOCATION OF ALL

BUILDING STRUCTURAL ELEMENTS. ALL BUILDING STRUCTURAL ELEMENTS SHALL

REMAIN UNLESS INDICATED TO BE REMOVED ON THE STRUCTURAL DRAWINGS. ANY

BUILDING STRUCTURAL ELEMENT INDICATED AS BEING REMOVED ON THIS DRAWING

SHALL BE CONFIRMED WITH THE ARCHITECT PRIOR TO COMMENCING REMOVALS

6. GC SHALL PROTECT, REPLACE OR REPAIR ANY EXISTING CONSTRUCTION

SCHEDULED TO REMAIN WHICH IS DAMAGED DURING REMOVALS

7. GC SHALL PROVIDE REQUIRED SHORING OR TEMPORARY BRACING DURING

REMOVALS

8. REMOVE EXISTING CEILINGS AND SUPPORTS WHERE NEW CEILINGS ARE

SCHEDULED IN THE ROOM FINISH SCHEDULE.

9. REMOVE PARTITIONS, FIXTURES, TOILET ACCESSORIES, SHELVING, CABINETRY

AND ALL MISCELLANEOUS ITEMS SHOWN WITH DASHED LINES.

10. PATCH ALL FLOORS, WALLS, BASE AND CEILINGS WHERE PARTITIONS OR

MISCELLANEOUS ITEMS ARE REMOVED.

11. REMOVE DOORS, FRAMES AND SIDELIGHTS SHOWN WITH DASHED LINES,

UNLESS OTHERWISE NOTED.

12. REMOVE TOILET PARTITIONS AND GRAB BARS SHOWN WITH DASHED LINES.

REPAIR EXISTING CONSTRUCTION SCHEDULED TO REMAIN.

13. REMOVE EXISTING FLOR AND WALL TILE WHERE NEW IS SCHEDULED IN THE

ROOM FINISH SCHEDULE AND PREPARE EXISTING FLOOR AND WALL SURFACES TO

RECEIVE NEW FINISHES.

14. CONTRACTOR SHALL VERIFY WITH THE OWNER THOSE REMOVED ITEMS TO BE

TURNED OVER TO THE OWNER.

R8R8

R9

R9

R10

R4

R4

R3

R3

R4

R4

R4

R4

R3

R9

R7

R7

R1

R2

B64-A130

LACTATION

B64-A129

RESTROOM

B64-A127

RESTROOM

R1

R2

R1

R2

WAITING

B64-A125

R2

R2

MEN

B64-C136

WOMEN

B64-C135

R4

R4

R4

R4

R4

R3

R1

R2

R4

CORRIDOR

B64-C1-9

R9

101 SF

BLOOD SPEC.

B64-2-C131

R4R4

R9

R9

R4R4

R8

R1

R2

R1

R2

B64-2-C132

TOILET

B64-2-C133

TOILET

R1

WAITING

B64-2-C1-2

R6 R12R12

MEN'S

RESTROOM

B19-113

R4

R4

R2

R1 R3

R13

CORRIDOR

B19-C1-7

R9

MEN

B64-B204

R1 R4 R4

R4

R9

R7

R2

R3R3

(5'-0" MIN. CLEAR)

6' - 0"

MEN'S

RESTROOM

B64-A137

R2

R3

R4

R4

R2 R2

R4

R2

R4

R1

(5 M

IN

C L E A R

R9

R15

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :1 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AD102

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

ENLARGED RESTROOM

DEMOLITION PLANS

FULLY SPRINKLERED

R1 REMOVE ALL FINISHES, INCLUDING TILE FLOORING, TILE WAINSCOT, ACT OR

GYPSUM CEILINGS. SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION.

R2 REMOVE ALL EXISTING TOILET ACCESSORIES.

R3 REMOVE ALL EXISTING TOILET PARTITIONS.

R4 REMOVE EXISTING PLUMBING FIXTURES - SEE PLUMBING DRAWINGS FOR

ADDITIONAL INFORMATION.

R6 REMOVE WALL AS SHOWN TO CREATE NEW WALL OPENING - REFER TO NEW

WORK PLANS FOR ADDITIONAL INFORMATION.

R7 SLECTIVLY REMOVE PORTION OF EXISTING WALL TO PREPARE FOR

INSTATLLATION OF NEW DOOR AND FRAME - REFER TO NEW WORK PLANS FOR

ADDITIONAL INFORMATION.

R8 REMOVE EXISTING WALL SHOWN DASHED.

R9 REMOVE EXISTING DOOR AND FRAME.

R10 REMOVE EXISTING CASEWORK SHOWN DASHED.

R12 EXTENTS OF EXISTING FLOORING TO BE REMOVED - REFER TO NEW WORK PLANS

FOR ADDITIONAL INFORMATION.

R13 EXISTING ELECTRICAL PANEL TO REMAIN - SEE ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

R15 REMOVE EXISTING RADIATOR UNIT - SEE MECHANICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

KEYNOTES

1/4" = 1'-0" AS101

1 DEMOLITION PLAN B64 - RM A127, A129, & A130

1/4" = 1'-0" AS101

3 DEMOLITION PLAN B64 - RM C136

1/4" = 1'-0" AS101

2 DEMOLITION PLAN B64-2 - RM C132 & C133

1/4" = 1'-0" AS101

4 DEMOLITION PLAN B19 - RM 113

1/4" = 1'-0" AS102

5 DEMOLITION PLAN B64 - RM B204

1/4" = 1'-0" AS101

6 DEMOLITION PLAN B64 - RM A137

GENERAL NOTES:

1. ALL WALL PARTITION TYPES ARE M4 UNLESS NOTED OTHERWISE. SEE SHEET AE500

FOR PARTITION TYPES.

2. REFER TO GI002 SHEET FOR ALL ABBREVIATIONS AND SYMBOLS.

3. REFER TO ALL DRAWINGS INCLUDING ARCHITECTURAL, MECHANICAL, PLUMBING,

AND ELECTRICAL DRAWINGS FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS, AND

SYMBOLS.

4. VERIFY ALL EQUIPMENT OPENINGS & RECOMMENDATIONS. LOCATION AND SIZES

SHOWN ARE FOR INTENT PURPOSES ONLY. ADJUST ROUGH OPENINGS AND

LOCATIONS AS REQUIRED PER ACTUAL EQUIPMENT.

5. DOOR JAMBS ARE 4" FROM NEAREST ADJACENT INTERSECTING PARTITION UNLESS

NOTED OTHERWISE. SEE DOOR DETAILS FOR FURTHER INFORMATION

6. G.C. TO PROVIDE & INSTALL ALL IN-WALL OR IN-CEILING BLOCKING / BRACING AS

REQUIRED FOR ALL MILLWORK ITEMS, EQUIPMENT, SHELVING, AND ACCESSORIES

WHETHER ITEMS ARE BY G.C. OR OTHERS COORDINATE WITH OWNER

7. G.C. SHALL BE RESPONSIBLE FOR LAYING OUT THE SPACE PRIOR TO COMMENCING

WORK AND SHALL NOTIFY THE ARCHITECT AND OWNER OF ANY DISCREPANCIES.

8. REFER TO SHEET AE500 FOR DOOR SCHEDULE AND FRAMING TYPES.

9. ALL INTERIOR DIMENSIONS SHOWN ARE TO FACE OF FRAMING UNLESS

SPECIFICALLY NOTED OTHERWISE.

10. ALL DRAWINGS ARE OF EQUAL IMPORTANCE IN DEFINING THE WORK OF THE

CONTRACT DOCUMENTS. CONTRACTORS SHALL REVIEW ALL DRAWINGS BEFORE THE

INSTALLATION OF THEIR WORK. SHOULD THERE BE A DISCREPANCY WITHIN AND

BETWEEN THE DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER

INSTALLATION NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO INSTALLATION OF

SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL

DRAWINGS, SHALL BE CORRECTED BY CONTRACTOR AT THEIR EXPENSE AND AT NO

ADDITIONAL COST TO THE OWNER OR ARCHITECT.

11. DO NOT SCALE DRAWINGS, THE DRAWINGS ARE NOT NECESSARILY TO SCALE -

USE GIVEN DIMENSIONS. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND

DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF

DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT FOR CLARIFICATION BEFORE

COMMENCING THE WORK.

12. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE

SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED

CONSULT ARCHITECT BEFORE PROCEEDING WITH THE WORK.

13. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE, UNLESS OTHERWISE

NOTED.

14. REFER TO MECHANICAL AND ELECTRICAL CONTRACTORS DRAWINGS AND

MANUFACTURES TEMPLATE DRAWINGS FOR ALL MECHANICAL AND ELECTRICAL

EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATIONS, SPRING ISOLATION,

ETC. NOT SHOWN ON THE DRAWINGS

15. OWNER FURNISHED ITEMS THE G.C. SHALL COORDINATE AND PROVIDE

ELECTRICAL, PLUMBING, AND MECHANICAL CONNECTIONS FOR ALL EQUIPMENT.

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

NEW PARTITION (SEE PARTITION

TYPES FOR ADDITIONAL INFO.)

TEMPORARY PARTITION

NOTES:

TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION

REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY

PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS

AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.

PARTITION LEGEND:

178 SF

MEN'S

RESTROOM

B38-123

AE201

9d

9a

9b

9c

MIN. CLEAR

5' - 0"

TBA-3

TBA-2

TBA-1

TBA-4

TBA-3

TBA-2

TBA-1

TBA-4

F3

F3

B38-123

M4A

M4A

F3

114 SF

WOMEN'S

RESTROOM

B62-113A

124 SF

MEN'S

RESTROOM

B62-113

AE201

3c

3a

3b

3d

AE201

8b

8c

8d

8a

B62-113F2F2

MIN. CLEAR

5' - 0"M4A

M4A

TBA-8

TBA-8 ALIGN

ALIGN

MA2

TBA-1

TBA-7

TBA-4

TBA-3 TBA-2

TBA-3

TBA-2

TBA-4

TBA-1

B62-113A

MA2

MA2

148 SF

MEN'S

RESTROOM

B64-C237

AE202

8d

8a

8b

8c

F1

B -C

M

IN

C L E A R

F3

F3 F3

TBA-3

TBA-2

TBA-1

TBA-4

TBA-8

TBA-2 TBA-2

TBA-3

TBA-3

1' - 0"

60 SF

UNISEX

RESTROOM

B64-A401A

AE202

10b

10c

10d

10a

B64-A401A

WAITING

B64-A401

(5 M

IN

C L E A R

M4A

M4

M4

M4AM4A

TBA-2

TBA-3

TBA-1

TBA-7

TBA-4

8' - 0"

(5'-0" MIN. CLR)

5' - 10"

AE202

9b

9c

9d

9a

61 SF

RESTROOM

B64-A444

WAITING

B64-A444A

B -A

B64-A444A

(5'-0" MIN. CLEAR)

6' - 0" M4A

M4A

M4

TBA-2

TBA-3

TBA-1

TBA-4TBA-7

F1

F1

M4A

M4A

61 SF

WOMEN

B64-2-CB5

100 SF

MEN

B64-2-CB4

AE202

1b

1a 1c

1d

AE2026a

6b

6c

6d

B64-2-CB4

B64-2-CB5

(5'-0" MIN. CLEAR)

5' - 6"

(5'-0" MIN. CLEAR)

5' - 6"

M4A

TBA-4

TBA-4

TBA-1

TBA-3

TBA-2

TBA-2

TBA-3

TBA-1

TBA-7

60 SF

TOILET

B64-2-138J

AE202 7c

7b

7a

7d

(M

IN

C L E A R

61 SF

STAFF

B64-2-138L

2' - 0" 8' - 7" 9' - 9"

AE202

3d

3a

3b

3c

F1 F1

10"

B -2 -C L

B -2 -C J

M6

MA2MA2

M4A M4A

M4A

TBA-3

TBA-2

TBA-8

TBA-4

TBA-7

TBA-1

TBA-1

TBA-4

TBA-3

TBA-2

57 SF

RESTROOM

B64-2-C144

AE202

2b

2c

2d

2aB64-2-C144

5'-0" MIN. CLR

5' - 9"

TBA-2

TBA-3

TBA-4

TBA-1

AE201

2b

2c

2d

2a

60 SF

MEN'S

RESTROOM

B82-258

B82-259

WOMEN

(5'-0" MIN. CLEAR)

5' - 6"

B82-258

M4A

TBA-3TBA-2

TBA-1

TBA-4

AE201

1b

1a

1d

1c

60 SF

MEN'S

RESTROOM

B82-366

B82-368

WOMEN

(5'-0" MIN. CLEAR)

5' - 6"

M4A

B82-336

TBA-3

TBA-1

TBA-4

TBA-2

AE201

6b

6c

6d

6a

60 SF

MEN'S

RESTROOM

B82-481

B82-481

B82-482

WOMEN

(5'-0" MIN. CLEAR)

5' - 6"

M4A

TBA-3TBA-2

TBA-4

TBA-1 AE201

7b

7c

7d

7a

60 SF

MEN'S

RESTROOM

B82-168

B82-167

WOMEN

(5'-0" MIN. CLEAR)

5' - 6"

M4A

B82-168

TBA-4

TBA-2

TBA-1

TBA-3

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :3 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AE101

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

ENLARGED NEW WORK

RESTROOM FLOOR PLANS

FULLY SPRINKLERED

F1 INFILL EXISTING DOOR OPENING TO MATCH EXISTING ADJACENT WALL

CONSTRUCITON.

F2 INFILL EXISTING WALL OPENING TO CREATE A FLUSH WALL TO RECIEVE NEW

FINISHES, BOTH SIDES OF THE WALL.

F3 TOILET PARTITION

KEYNOTES:

1/4" = 1'-0"

3 NEW FLOOR PLAN B38 - RM 123

1/4" = 1'-0"

6 NEW FLOOR PLAN B62 - RMS 113 & 113A

1/4" = 1'-0"

2 NEW FLOOR PLAN B64 - RM C237

1/4" = 1'-0"

12 NEW FLOOR PLAN B64 - RM A401A

1/4" = 1'-0"

9 NEW FLOOR PLAN B64 - RM A443 & A444B

1/4" = 1'-0"

11 NEW FLOOR PLAN B64-2 - RM CB4 & CB5

1/4" = 1'-0"

5 NEW FLOOR PLAN B64-2 - RMS C138J & C138L

1/4" = 1'-0"

8 NEW FLOOR PLAN B64-2 - RM C144

1/4" = 1'-0"

4 NEW FLOOR PLAN B82 - RM 258

1/4" = 1'-0"

7 NEW FLOOR PLAN B82 - RM 366

1/4" = 1'-0"

10 NEW FLOOR PLAN B82 - RM 481

1/4" = 1'-0"

1 NEW FLOOR PLAN B82 - RM 168

BLOOD SPEC.

B64-2-C131

61 SF

UNISEX

B64-C132

AE203

1a

1c

1d 1b

E.T. / 2

B64-C114

ELEC.

B64-C118

E.T. / 9

B64-C120 E.T. / 10

B64-C128

SATELLITE LAB

B64-C130

E.T. / 1

B64-C113

WAITING

B64-2-C1-2

B -C

M4AM4A

M4M4

TBA-8

TBA-2

TBA-1

TBA-7

TBA-3

/8

4' - 2"

60 SF

WOMEN

B64-A127

55 SF

LACTATION

B64-A129

60 SF

MEN

B64-A130 AE203 5b5d

5a

5c

AE203

3a

3c

3b3d

AE2034d

4c

4b

4a

5' - 0"

6' - 6" 10"

F1

F1

WAITING

B64-A125

B64-A127

B64-A129

B -A

TBA-2

TBA-3

TBA-4

TBA-1

TBA-7

TBA-8

TBA-2

TBA-3

TBA-2

TBA-8

TBA-4

TBA-1

TBA-3

M4

M4A M4A

M4

M4

M4A

M4A

145 SF

MEN

B64-C136

123 SF

WOMEN

B64-C135

AE203

2d 2c

2b2a

B64-C136

TBA-2

TBA-1TBA-4

TBA-2

TBA-3

TBA-3

F3

F3

F3

TBA-3

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

NEW PARTITION (SEE PARTITION

TYPES FOR ADDITIONAL INFO.)

TEMPORARY PARTITION

NOTES:

TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION

REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY

PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS

AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.

PARTITION LEGEND:

GENERAL NOTES:

1. ALL WALL PARTITION TYPES ARE M4 UNLESS NOTED OTHERWISE. SEE SHEET AE500

FOR PARTITION TYPES.

2. REFER TO GI002 SHEET FOR ALL ABBREVIATIONS AND SYMBOLS.

3. REFER TO ALL DRAWINGS INCLUDING ARCHITECTURAL, MECHANICAL, PLUMBING,

AND ELECTRICAL DRAWINGS FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS, AND

SYMBOLS.

4. VERIFY ALL EQUIPMENT OPENINGS & RECOMMENDATIONS. LOCATION AND SIZES

SHOWN ARE FOR INTENT PURPOSES ONLY. ADJUST ROUGH OPENINGS AND

LOCATIONS AS REQUIRED PER ACTUAL EQUIPMENT.

5. DOOR JAMBS ARE 4" FROM NEAREST ADJACENT INTERSECTING PARTITION UNLESS

NOTED OTHERWISE. SEE DOOR DETAILS FOR FURTHER INFORMATION

6. G.C. TO PROVIDE & INSTALL ALL IN-WALL OR IN-CEILING BLOCKING / BRACING AS

REQUIRED FOR ALL MILLWORK ITEMS, EQUIPMENT, SHELVING, AND ACCESSORIES

WHETHER ITEMS ARE BY G.C. OR OTHERS COORDINATE WITH OWNER

7. G.C. SHALL BE RESPONSIBLE FOR LAYING OUT THE SPACE PRIOR TO COMMENCING

WORK AND SHALL NOTIFY THE ARCHITECT AND OWNER OF ANY DISCREPANCIES.

8. REFER TO SHEET AE500 FOR DOOR SCHEDULE AND FRAMING TYPES.

9. ALL INTERIOR DIMENSIONS SHOWN ARE TO FACE OF FRAMING UNLESS

SPECIFICALLY NOTED OTHERWISE.

10. ALL DRAWINGS ARE OF EQUAL IMPORTANCE IN DEFINING THE WORK OF THE

CONTRACT DOCUMENTS. CONTRACTORS SHALL REVIEW ALL DRAWINGS BEFORE THE

INSTALLATION OF THEIR WORK. SHOULD THERE BE A DISCREPANCY WITHIN AND

BETWEEN THE DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER

INSTALLATION NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO INSTALLATION OF

SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL

DRAWINGS, SHALL BE CORRECTED BY CONTRACTOR AT THEIR EXPENSE AND AT NO

ADDITIONAL COST TO THE OWNER OR ARCHITECT.

11. DO NOT SCALE DRAWINGS, THE DRAWINGS ARE NOT NECESSARILY TO SCALE -

USE GIVEN DIMENSIONS. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND

DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF

DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT FOR CLARIFICATION BEFORE

COMMENCING THE WORK.

12. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE

SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED

CONSULT ARCHITECT BEFORE PROCEEDING WITH THE WORK.

13. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE, UNLESS OTHERWISE

NOTED.

14. REFER TO MECHANICAL AND ELECTRICAL CONTRACTORS DRAWINGS AND

MANUFACTURES TEMPLATE DRAWINGS FOR ALL MECHANICAL AND ELECTRICAL

EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATIONS, SPRING ISOLATION,

ETC. NOT SHOWN ON THE DRAWINGS

15. OWNER FURNISHED ITEMS THE G.C. SHALL COORDINATE AND PROVIDE

ELECTRICAL, PLUMBING, AND MECHANICAL CONNECTIONS FOR ALL EQUIPMENT.

69 SF

MEN'S

RESTROOM

B19-113

AE201

4b

4a

4d

4c

CORRIDOR

B19-C1-7

B -1

F5TBA-2

TBA-1

TBA-4

TBA-3

69 SF

MEN

B64-B204 AE202

4a

4c

4b

4d

(5'-0" MIN. CLEAR)

6' - 0" 3' - 0"

B64-B204

TBA-2

TBA-3

TBA-4

TBA-1

EXISTING RESTROOM B204 IS TOO

NARROW TO ACCOMMODATE VA

REQUIRED TURNING RADIUS, OMIT

HANDICAPPED SIGNAGE ON DOOR

119 SF

MEN'S

RESTROOM

B64-A137

AE2025a

5b

5c

5d

(5 M

IN

C L E A R

TBA-1

TBA-4

TBA-8

TBA-2

TBA-3

B -A

F3

F3

/8 "2

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :3 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AE102

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

ENLARGED NEW WORK

RESTROOM FLOOR PLANS

FULLY SPRINKLERED

F1 INFILL EXISTING DOOR OPENING TO MATCH EXISTING ADJACENT WALL

CONSTRUCITON.

F3 TOILET PARTITION

F5 EXISTING ELECTRICAL PANEL TO REMAIN - SEE ELECTRICAL DRAWINGS FOR

ADDITIONAL INFORMATION.

KEYNOTES:

1/4" = 1'-0"

2 NEW FLOOR PLAN B64 - RM C132

1/4" = 1'-0"

1 NEW FLOOR PLAN B64 - RM A127, A129, & A130

1/4" = 1'-0"

3 NEW FLOOR PLAN B64 - RM C136

1/4" = 1'-0"

4 NEW FLOOR PLAN B19 - RM 113

1/4" = 1'-0"

5 NEW FLOOR PLAN B64 - RM B204

1/4" = 1'-0"

6 NEW FLOOR PLAN B64 - RM A137

MEN'S

RESTROOM

B38-123 8' - 0"ACP-1

WOMEN'S

RESTROOM

B62-113A

MEN'S

RESTROOM

B62-113

8' - 0"ACP-1

8' - 0"ACP-1

MEN'S

RESTROOM

B64-C237 8' - 0"ACP-1

NEW CUBICAL TRACK

AND CURTAIN

UNISEX

RESTROOM

B64-A401A

8' - 0"ACP-1

RESTROOM

B64-A444

8' - 0"ACP-1

MEN

B64-2-CB4

WOMEN

B64-2-CB5

8' - 0"ACP-1

8' - 0"ACP-1

TOILET

B64-2-138J

8' - 0"ACP-1

8' - 0"ACP-1

STAFF

B64-2-138L

RESTROOM

B64-2-C144

8' - 0"ACP-1

MEN'S

RESTROOM

B82-258 8' - 0"ACP-1

8' - 0"ACP-1

MEN'S

RESTROOM

B82-366

8' - 0"ACP-1

MEN'S

RESTROOM

B82-481

CEILING LEGEND

GWB ATTACHED

TO HM STUD

REFLECTED CEILING PLAN NOTES:

1. ALL CEILINGS TO BE 8'-0" AFF UNLESS NOTED OTHERWISE.

2. REFER TO SHEET GI002 FOR ALL ABBREVIATIONS

3. CONTRACTOR TO VERIFY LOCATIONS OF MAIN CEILING TEES BEFORE

PROCEEDING WITH FIXTURE INSTALLATION. NOTIFY ARCHITECT OF

INTERFERENCES.

4. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL

REFLECTED CEILING PLANS AND ELECTRICAL LIGHTING PLANS PRIOR TO

CONSTRUCTION.

5. REFER TO ELECTRICAL PLANS FOR LOCATIONS OF STROBES AND EXIT SIGNS.

6. ALL CEILING GRILLES, TRIM EDGES AND SLOT DIFFUSERS TO MATCH ADJACENT

CEILING COLOR.

7. ALL SPRINKLER HEADS TO OCCUR AT CENTER OF TILES.

8. LAYOUT TILES AS SHOWN IN REFLECTED CEILING PLANS.

9. REFER TO SPECIFICATIONS FOR ALL ACOUSTICAL PANEL CEILING TYPES.

10. SEE AS501 SHEETS FOR ROOM FINISH SCHEDULE FOR CEILING FINISH

INFORMATION.

11. WHERE NO CEILING MATERIAL IS SHOWN THE STRUCTURE ABOVE IS TO BE

EXPOSED, U.N.O.

12. SEE EL SHEETS FOR CONTINUED LIGHTING INFORMATION

13. SEE MH SHEETS FOR CONTINUED MECHANICAL INFORMATION.

ELECTRICAL SYMBOLS INDICATING LIGHTING LOCATIONS.

REFER TO EL SHEETS FOR SIZE/ TYPE OF LIGHTING FIXTURE

MECHANICAL SYMBOLS INDICATING SUPPLY DIFFUSER OR

EXHAUST/ RETURN GRILLE LOCATIONS. REFER TO MH

SHEETS FOR SIZE/ TYPE OF DIFFUSER/ GRILLE.

ACOUSTICAL TILE CEILING

2'-0" x 2'-0" ON METAL

SUSPENSION GRID

NO HATCH SHOWN

INDICATES EXISTING CEILING

TO REMAIN, UNLESS NOTED

OTHERWISE

SPRINKLER HEAD LOCATIONS - SEE FP DRAWINGS FOR

ADDITIONAL INFORMATIN

ROOM OCCUPANCY SENSOR - SEE ELECTRICAL

DRAWINGS FOR ADDITIONAL INFORMATION

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

NEW PARTITION (SEE PARTITION

TYPES FOR ADDITIONAL INFO.)

TEMPORARY PARTITION

NOTES:

TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION

REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY

PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS

AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.

PARTITION LEGEND:

MEN'S

RESTROOM

B82-168

8' - 0"ACP-1

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :4 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AE111

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

ENLARGED RESTROOM

REFLECTED CEILING PLANS

FULLY SPRINKLERED

1/4" = 1'-0"

3 REFLECTED CEILING PLAN B38 - RM 123

1/4" = 1'-0"

6 REFLECTED CEILING PLAN B62 - RM 113 & 113A

1/4" = 1'-0"

2 REFLECTED CEILING PLAN B64 - RM C237

1/4" = 1'-0"

12 REFLECTED CEILING PLAN B64 - RM A401A

1/4" = 1'-0"

9 REFLECTED CEILING PLAN B64 - A443 & A444B

1/4" = 1'-0"

11 REFLECTED CEILING PLAN B64 - RMS CB4 & CB5

1/4" = 1'-0"

5 REFLECTED CEILING PLAN B64 - C138J & C138L

1/4" = 1'-0"

8 REFLECTED CEILING PLAN B64 - RM C144

1/4" = 1'-0"

4 REFLECTED CEILING PLAN B82 - RM 256

1/4" = 1'-0"

7 REFLECTED CEILING PLAN B82 - RM 366

1/4" = 1'-0"

10 REFLECTED CEILING PLAN B82 - RM 481

1/4" = 1'-0"

1 REFLECTED CEILING PLAN B82 - RM168

CEILING LEGEND

GWB ATTACHED

TO HM STUD

REFLECTED CEILING PLAN NOTES:

1. ALL CEILINGS TO BE 8'-0" AFF UNLESS NOTED OTHERWISE.

2. REFER TO SHEET GI002 FOR ALL ABBREVIATIONS

3. CONTRACTOR TO VERIFY LOCATIONS OF MAIN CEILING TEES BEFORE

PROCEEDING WITH FIXTURE INSTALLATION. NOTIFY ARCHITECT OF

INTERFERENCES.

4. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL

REFLECTED CEILING PLANS AND ELECTRICAL LIGHTING PLANS PRIOR TO

CONSTRUCTION.

5. REFER TO ELECTRICAL PLANS FOR LOCATIONS OF STROBES AND EXIT SIGNS.

6. ALL CEILING GRILLES, TRIM EDGES AND SLOT DIFFUSERS TO MATCH ADJACENT

CEILING COLOR.

7. ALL SPRINKLER HEADS TO OCCUR AT CENTER OF TILES.

8. LAYOUT TILES AS SHOWN IN REFLECTED CEILING PLANS.

9. REFER TO SPECIFICATIONS FOR ALL ACOUSTICAL PANEL CEILING TYPES.

10. SEE AS501 SHEETS FOR ROOM FINISH SCHEDULE FOR CEILING FINISH

INFORMATION.

11. WHERE NO CEILING MATERIAL IS SHOWN THE STRUCTURE ABOVE IS TO BE

EXPOSED, U.N.O.

12. SEE EL SHEETS FOR CONTINUED LIGHTING INFORMATION

13. SEE MH SHEETS FOR CONTINUED MECHANICAL INFORMATION.

ELECTRICAL SYMBOLS INDICATING LIGHTING LOCATIONS.

REFER TO EL SHEETS FOR SIZE/ TYPE OF LIGHTING FIXTURE

MECHANICAL SYMBOLS INDICATING SUPPLY DIFFUSER OR

EXHAUST/ RETURN GRILLE LOCATIONS. REFER TO MH

SHEETS FOR SIZE/ TYPE OF DIFFUSER/ GRILLE.

ACOUSTICAL TILE CEILING

2'-0" x 2'-0" ON METAL

SUSPENSION GRID

NO HATCH SHOWN

INDICATES EXISTING CEILING

TO REMAIN, UNLESS NOTED

OTHERWISE

SPRINKLER HEAD LOCATIONS - SEE FP DRAWINGS FOR

ADDITIONAL INFORMATIN

ROOM OCCUPANCY SENSOR - SEE ELECTRICAL

DRAWINGS FOR ADDITIONAL INFORMATION

EXISTING WALL TO REMAIN

EXISTING WALL TO BE DEMOLISHED

NEW PARTITION (SEE PARTITION

TYPES FOR ADDITIONAL INFO.)

TEMPORARY PARTITION

NOTES:

TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION

REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY

PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS

AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.

PARTITION LEGEND:

8' - 0"ACP-1

MEN

B64-C136

WOMEN

B64-C135

UNISEX

B64-C132

8' - 6"ACP-1

8' - 6"ACP-1

BLOOD SPEC.

B64-2-C131

C1

WOMEN

B64-A127

MEN

B64-A130

LACTATION

B64-A129

8' - 0"ACP-1

8' - 0"ACP-1

8' - 0"ACP-1

MEN'S

RESTROOM

B19-113

7' - 10"ACP-1

MEN

B64-B204

8' - 6"ACP-1

MEN'S

RESTROOM

B64-A137

8' - 0"ACP-1

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

Project TitleDrawing Title

Approved:

Phase

Location

Issue Date

Project Number

Building Number

Drawing Number

Checked Drawn

TRUE NORTH WBRC

A R C H I T E C T S • E N G I N E E R S

WWW.WBRCAE.COM

BANGOR, MAINE 207-947-4511

PORTLAND, MAINE 207-828-4511

SARASOTA, FLORIDA 941-556-0757

www.abovegroupinc.com COA/CA Lic. No. 31120

305 East Dr., Suite H, Melbounre, Florida 32904

PH: 321.345.9026

/3 /2 :5 :4 A M

U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C

IT

Y R E N O V A T

IO

N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt

AE112

573A4-18-606RENOVATE COMMON

AREA RESTROOMS

DWW AMC07/09/2021

100% CONSTRUCTION

DOCUMENTS

ENLARGED RESTROOM

REFLECTED CEILING PLANS

FULLY SPRINKLERED

C1 PROVIDE SOFFIT TO MATCH EXISTING WALL THICKNESS @ 7'-0" A.F.F.

KEYNOTES:

1/4" = 1'-0"

3 REFLECTED CEILING PLAN B64 - RM C136

1/4" = 1'-0"

2 REFLECTED CEILING PLAN B64 - RM C132

1/4" = 1'-0"

1 REFLECTED CEILING PLAN B64 - RM A127, A129 & A130