J.02 Attachment 02 - Drawings.pdf
PDF 40 MB Posted
- Solicitation number
- 36C24822R0148
About this file
This federal contract opportunity solicitation seeks construction services for renovating common area restrooms at the Lake City VA Medical Center in Lake City, Florida. The project number is 573A4-18-606, with a site visit scheduled for August 15, 2022 at 10:00 AM. Proposals are due by August 31, 2022 at 3:30 PM. This is a set-aside opportunity for Service-Disabled Veteran-Owned Small Businesses. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8. Attached drawings related to the renovation project are provided in the J.02 Attachment 02 - Drawings.pdf file.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| WAGE DETERMINATION.pdf | ||
| PRICE SCHEDULE.docx | DOCX document | |
| J.11 Attachment 11 - VHA Supplemental Contract Requirements for Combatting COVID-19 (2 pages).docx | DOCX document | |
| J.08 Attachment 08 - EMR.docx | DOCX document | |
| J.03 Attachment 03 - Specifications.pdf | ||
| J.10 Attachment 10 - Specialized Experience Form [pages].pdf | ||
| J.01 Attachment 01 - Statement of Work.docx | DOCX document | |
| J.07 Attachment 07 - Past Performance Questionnaire.docx | DOCX document | |
| J.06 Attachment 06 -Price Matric.xls | XLS spreadsheet | |
| J.05 Attachment 05 - LOS Certification.doc | DOC document | |
| J.09 Attachment 09 - Experience Information Sheet.docx | DOCX document | |
| S02 - SOLICITATION - BB OPEN MARKET.pdf | ||
| J.04 Attachment 04 - Wage Determination.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FL 941-556-0757
VA PROJECT NO. 573A4-18-606
RENOVATE COMMON AREA RESTROOMS
LAKE CITY
VETERANS AFFAIRS MEDICAL CENTER
DESIGNED FOR: ARCHITECT:
LAKE CITY VA MEDICAL CENTER
619 S MARION AVE, LAKE CITY, FL 32025
PROJECT LOCATION MAP
VICINITY MAP
PROJECT LOCATION
VICINITY MAP
LAKE CITY, FL
NOT TO SCALE
VAMC
PROJECT
LOCATION
247 N
WWW.ABOVEGROUPINC.COM
COA/CA Lic. No. 31120
305 EAST DR. SUITE H, MELBOURNE, FLORIDA 32904
PH: 321.345.9026
ENGINEER:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbourne, Florida 32904
PH: 321.345.9026
C U s e rs
\c v a n m e te r.
A
B O
V E
G R
O U
P \D o c u m e n ts
\0
R e n o v a te C o m m o n A re a R e s tr o o m s E
P
R c v a n m e te rP N
X X
.r v t
/2
/2
:4
:5
P
M
GI-001
COVER SHEET RENOVATE COMMON
AREA RESTROOMS
LAKE CITY VAMC, FL
573A4-18-606
03/01/2021 KJD MRK
100% CONSTRUCTION
DOCUMENTS
KYLE J. DAVIS, P.E.
FL License #84275
DRAWING INDEX
Sheet Number Sheet Name
E-123 ELECTRICAL LEVEL 2 - BLDG 82
E-131 ELECTRICAL LEVEL 3 - BLDG 82
E-141 ELECTRICAL LEVEL 4 - BLDG 64
E-142 ELECTRICAL LEVEL 4 - BLDG 82
E-501 ELECTRICAL DETAILS
E-502 ELECTRICAL DETAILS & SCHEDULES
PL-001 PLUMBING LEGENDS, NOTES & SYMBOLS
PL-101A PLUMBING BASEMENT GRAVITY LEVEL - BLDG. 64
PL-101B PLUMBING BASEMENT PRESSURE LEVEL - BLDG. 64
PL-110 PLUMBING LEVEL 1 - BLDG. 19
PL-111 PLUMBING LEVEL 1 - BLDG. 38
PL-112 PLUMBING LEVEL 1 - BLDG. 62
PL-113 PLUMBING LEVEL 1 - BLDG. 64
PL-114 PLUMBING LEVEL 1 - BLDG. 64
PL-115A PLUMBING GRAVITY LEVEL 1 - BLDG. 64
PL-115B PLUMBING PRESSURE LEVEL 1 - BLDG. 64
PL-116A PLUMBING GRAVITY LEVEL 1 - BLDG. 64
PL-116B PLUMBING PRESSURE LEVEL 1 - BLDG. 64
PL-117A PLUMBING GRAVITY LEVEL 1 - BLDG. 64
PL-117B PLUMBING PRESSURE LEVEL 1 - BLDG. 64
PL-118A PLUMBING GRAVITY LEVEL 1 - BLDG. 64
PL-118B PLUMBING PRESSURE LEVEL 1 - BLDG. 64
PL-119 PLUMBING LEVEL 1 - BLDG. 82
PL-121A PLUMBING GRAVITY LEVEL 2 - BLDG. 64
PL-121B PLUMBING PRESSURE LEVEL 2 - BLDG. 64
PL-122 PLUMBING LEVEL 2 - BLDG. 64
PL-123 PLUMBING LEVEL 2 - BLDG. 82
PL-131 PLUMBING LEVEL 3 - BLDG. 82
PL-141 PLUMBING LEVEL 4 - BLDG. 64
PL-142 PLUMBING LEVEL 4 - BLDG. 64
PL-143 PLUMBING LEVEL 4 - BLDG. 82
PL-201 PLUMBING DETAILS
PL-301 PLUMBING ISOMETRICS
F-001 FIRE PROTECTION LEGENDS, NOTES & SYMBOLS
FA-101 FIRE PROTECTION BASEMENT LEVEL - BLDG. 64
FA-111 FIRE PROTECTION LEVEL 1 - BLDG. 19
FA-112 FIRE PROTECTION LEVEL 1 - BLDG. 38
FA-113 FIRE PROTECTION LEVEL 1 - BLDG. 62
FA-114 FIRE PROTECTION LEVEL 1 - BLDG. 64
FA-115 FIRE PROTECTION LEVEL 1 - BLDG. 64
FA-116 FIRE PROTECTION LEVEL 1 - BLDG. 64
FA-117 FIRE PROTECTION LEVEL 1 - BLDG. 64
FA-118 FIRE PROTECTION LEVEL 1 - BLDG. 82
FA-121 FIRE PROTECTION LEVEL 2 - BLDG. 64
FA-122 FIRE PROTECTION LEVEL 2 - BLDG. 64
FA-123 FIRE PROTECTION LEVEL 2 - BLDG. 82
FA-131 FIRE PROTECTION LEVEL 3 - BLDG. 82
FA-141 FIRE PROTECTION LEVEL 4 - BLDG. 64
FA-142 FIRE PROTECTION LEVEL 4 - BLDG. 82
DRAWING INDEX
Sheet Number Sheet Name
GI-001 COVER SHEET
GI-002 SYMBOLS AND ABBREVIATIONS
AS100 BASEMENT LOCATION PLANS
AS101 FIRST FLOOR LOCATION PLANS
AS102 SECOND, THIRD & FOURTH FLOOR LOCATION PLANS
AD101 ENLARGED RESTROOM DEMOLITION PLANS
AD102 ENLARGED RESTROOM DEMOLITION PLANS
AE101 ENLARGED NEW WORK RESTROOM FLOOR PLANS
AE102 ENLARGED NEW WORK RESTROOM FLOOR PLANS
AE111 ENLARGED RESTROOM REFLECTED CEILING PLANS
AE112 ENLARGED RESTROOM REFLECTED CEILING PLANS
AE201 INTERIOR ELEVATIONS
AE202 INTERIOR ELEVATIONS
AE203 INTERIOR ELEVATIONS
AE500 DOOR SCHEDULE/DETAILS & WALL TYPES
AE501 FINISH SCHEDULE & DETAILS
M-001 MECHANICAL LEGENDS, NOTES & SYMBOLS
MH-101 MECHANICAL BASEMENT LEVEL - BLDG. 64
MH-111 MECHANICAL LEVEL 1 - BLDG. 19
MH-112 MECHANICAL LEVEL 1 - BLDG. 38
MH-113 MECHANICAL LEVEL 1 - BLDG. 62
MH-114 MECHANICAL LEVEL 1 - BLDG. 64
MH-115 MECHANICAL LEVEL 1 - BLDG. 64
MH-116 MECHANICAL LEVEL 1 - BLDG. 64
MH-117 MECHANICAL LEVEL 1 - BLDG. 64
MH-118 MECHANICAL LEVEL 1 - BLDG. 64
MH-119 MECHANICAL LEVEL 1 - BLDG. 82
MH-121 MECHANICAL LEVEL 2 - BLDG. 64
MH-122 MECHANICAL LEVEL 2 - BLDG. 64
MH-123 MECHANICAL LEVEL 2 - BLDG. 82
MH-131 MECHANICAL LEVEL 3 - BLDG. 82
MH-141 MECHANICAL LEVEL 4 - BLDG. 64
MH-142 MECHANICAL LEVEL 4 - BLDG. 82
M-201 MECHANICAL DETAILS
M-301 MECHANICAL SCHEDULES
E-001 ELECTRICAL LEGENDS
E-002 ELECTRICAL GENERAL NOTES
E-003 ELECTRICAL GENERAL NOTES
E-004 ELECTRICAL GENERAL NOTES
E-101 ELECTRICAL BASEMENT LEVEL - BLDG. 64
E-111 ELECTRICAL LEVEL 1 - BLDG 19
E-112 ELECTRICAL LEVEL 1 - BLDG 38
E-113 ELECTRICAL LEVEL 1 - BLDG 62
E-114 ELECTRICAL LEVEL 1 - BLDG 64
E-115 ELECTRICAL LEVEL 1 - BLDG 64
E-116 ELECTRICAL LEVEL 1 - BLDG 64
E-117 ELECTRICAL LEVEL 1 - BLDG 64
E-118 ELECTRICAL LEVEL 1 - BLDG 82
E-121 ELECTRICAL LEVEL 2 - BLDG 64
E-122 ELECTRICAL LEVEL 2 - BLDG 64
Revisions: Date:
NOTE: REFER TO STRUCTURAL,
MECHANICAL, AND/OR ELECTRICAL
DRAWINGS FOR ABBREVIATIONS
SPECIFIC TO EACH DISCIPLINE.
AB ANCHOR BOLT, AUGER BORING
ABI ALTERNATE BID ITEM
AC ACOUSTIC AIR CONDITIONING,
ASPHALTIC CONCRETE
AD ACCESS DOOR
ADD ALT ADDITIVE ALTERNATE
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
AP ACCESS PANEL
APC ACOUSTIC PANEL CEILING
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASB ASBESTOS
ASPH ASPHALT
AUTO AUTOMATIC
AWP ACOUSTIC WALL PANEL
BIT. CONC BITUMINOUS CONCRETE
BJ BAR JOIST
BLDG BUILDING
BLK BLOCK
BM BEAM, BENCHMARK
BOT BOTTOM
BRD BOARD
BRG BEARING
BS BOTTOM OF STEP
BSMT BASEMENT
BTWN BETWEEN
BW BOTTOM OF WALL
CAB CABINET
CAP CAPACITY
CC CENTER TO CENTER
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIR CIRCULATING
CJ CONSTRUCTION JOINT, CONTROL JOINT
CLG CEILING
CLO CLOSET
CLR CLEAR
CENTERLINE
CMU CONCRETE MASONRY UNITS
CMU G1 GLAZED CMU, ONE SIDE
CMU G2 GLAZED CMU, TWO SIDES
CO CLEANOUT
COL COLUMN
COMP'T COMPARTMENT
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CS/CI CONTRACTOR SUPPLIED/ CONTRACTOR
INSTALLED
CS/OI CONTRACTOR SUPPLIED/OWNER
INSTALLED
CSK COUNTER SUNK
CT CERAMIC TILE
CTE CONNECT TO EXISTING
CTR CENTER
CUH CABINET UNIT HEATER
O DIAMETER
DF DRINKING FOUNTAIN
DFD DOOR FRAME DIMENSION
DH DOUBLE HUNG
DIA DIAMETER
DIM DIMENSION
DN DOWN
DTL DETAIL
DWG DRAWING
E EAST
EA EACH
EL, ELEV ELEVATION
ELEC ELECTRIC
EMERG EMERGENCY
EPS EXTRUDED POLYSTYRENE
EQ EQUAL
EQUIP EQUIPMENT
ETC ETCETERA
EW EACH WAY
EXIST EXISTING
EXP EXPANSION, EXPOSED
EXP JT EXPANSION JOINT
EXT EXTERIOR
FBO FURNISHED BY OTHERS
FCO FLOOR CLEAN-OUT
FD FLOOR DRAIN, FOOTING DRAIN
FE FIRE EXTINGUISHER
FF FINISH FLOOR
FFE FINISHED FLOOR ELEVATION
FG FINISH GRADE, FIBERGLASS
FHC FIRE HOSE CABINET
FIG FIGURE
FIN FINISH
FO FUEL OIL
FOF FACE OF FOUNDATION
FOR FUEL OIL RETURN
FOS FACE OF STUD, FUEL OIL SUPPLY
FOUND FOUNDATION
FP FIREPROOF
FR FRAME, FIRE RESISTANT
FS FLOOR SINK
FT FOOT, FEET, FINNED TUBE
FTG FOOTING
FWP FABRIC WALL PANEL
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GF/GI GOVT. FURNISHED/GOVT. INSTALLED
GF/CI GOVT. FURNISHED/CONTRACTOR
INSTALLED
GI GALVANIZED IRON
GOV'T GOVERNMENT
GPM GALLONS PER MINUTE
GR GRADE
GRAN GRANULAR
GRD GROUND
GWB GYPSUM WALLBOARD
GYP GYPSUM
HGT HEIGHT
H&V HEATING AND VENTILATING
HB HOSE BIB
HC HANDICAPPED
HCWD HOLLOW CORE WOOD DOOR
HDC HANDICAPPED
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
HVAC HEATING, VENTILATING, AND AIR
CONDITIONING
IN INSIDE DIAMETER
INCL INCLUSIVE
INFO INFORMATION
INSUL INSLUATION, INSULATED
INT INTERIOR
IWP IMPACT RESISTANT WALL PROTECTION
JAN JANITOR CLOSET
JCT JUNCTION
KV KILOVOLT
KW KILOWATT
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET
LFC LINOLEUM FLOOR COVERING
LGR LEDGER
LP LOW POINT
LR LIVING ROOM
LT LIGHT
LWC LIGHT WEIGHT CONCRETE
MACH MACHINE
MANUF MANUFACTURER
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MC MEDICINE CABINET
MCB METAL CORNER BEAD
MECH MECHANICAL
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MM MILLIMETER
MO MASONRY OPENING
MR MOISTURE RESISTANT
MS METAL STRIP
MTD MOUNTED
MTL METAL
N NORTH
N.I.C. NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OVER ALL
OB GL OBSCURE GLASS
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OS/CI OWNER SUPPLIED/CONTRACTOR
INSTALLED
OS/OI OWNER SUPPLIED/OWNER INSTALLED
OVHD, OH OVERHEAD
P-1 PLUMBING FIXTURE TYPE
PART PARTITION
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLAST PLASTIC
PLYWD PLYWOOD
PNL PANEL
PNTD PAINTED
POL POLISHED
PRELIM PRELIMINARY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, POINT, PRESSURE TREATED
PT DISP PAPER TOWEL DISPENSER
PVC POLY VINYL CHLORIDE
PVMT PAVEMENT
QT QUARRY TILE
R RADIUS, RISER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN, ROAD
RECEP RECEPTACLE
REF REFRIGERATOR
REINF REINFORCEMENT
REQ'D REQUIRED
REV REVISION
RF RESINOUS FLOOR
RL RAIN LEADER
RM ROOM
RO ROUGH OPENING
RS RESILIENT STAIR ACCESSORY
RT RUBBER TILE
S SOUTH
S DISP SOAP DISPENSER
S&V STAIN AND VARNISH
SCONC SEALED CONCRETE
SCWD SOLID CORE WOOD DOOR
SCH SCHEDULE
SCR SUPPLY CEILING REGISTER
SECT SECTION
SF SQUARE FEET
SH SINGLE HUNG
SHT SHEET
SIM SIMILAR
SL SLOPE
SPECS SPECIFICATIONS
SQ SQUARE
SQ FT SQUARE FEET
SS SERVICE SINK, SANITARY
SEWER, STAINLESS STEEL
SSURFACE SOLID SURFACE
ST STREET
STA STATION
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUP SUPPORT
SUSP SUSPEND
SV SHEET VINYL
SYM SYMMETRICAL
T TOP, TANGENT, THERMOMETER
TB TACK BOARD
TBA TOILET BATH ACCESSORIES
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
T.O.C. TOP OF CONCRETE
T.O.M. TOP OF MASONRY
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TEL TELEPHONE
TEMP TEMPERATURE, TEMPORARY
TERM TERMINAL
THK THICK
THRU THROUGH
TP TOILET PARTITION
TPH TOILET PAPER HOLDER
TRAN TRANSOM
TS TOP OF STEP, TOP OF SILL
TV TELEVISION
TYP TYPICAL
TYPE "X" UL APPROVED GWB
U&D UP AND DOWN
UC UNDERCUT
UV UNIT VENTILATOR
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
W WEST
WAIN WAINSCOT
WB RESILIENT WALL BASE
WC WALL COVERING
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WIDTH, WINDOW DIMENSION,
WOOD
WGL WIRE GLASS
WP WATERPROOF, WEATHERPROOF
WS WEATHERSTRIPPING
WT WEIGHT
WW WELDED WIRE FABRIC
DRAWING REFERENCED
FROM ANOTHER SHEET
DRAWING TITLE
DRAWING
INDICATOR
SCALE OF
DRAWING
F
E
D
1 2 3
1 View Name
1/8" = 1'-0" R101
A1
SCALE: 1/8" = 1'-0"
4' 8'0 16'
B3
D
C
B
A
SHEET NUMBER
DETAIL IS DRAWN ON
ROOM NAME
ROOM NUMBER
BREAK LINE
GRAPHIC SCALE
REVISION NUMBER
REVISION CLOUD
ELEVATION MARKER - SECTION
ELEVATION MARKER - PLAN
DOOR NUMBER REFERENCE
WINDOW TYPE REFERENCE
WALL TYPE REFERENCE
COLUMN GRID REFERENCE
SHEET NUMBER ELEVATION
IS DRAWN ON
INTERIOR ELEVATION
REFERENCE
BUILDING / WALL
SECTION NUMBER
SHEET NUMBER BUILDING /
WALL SECTION IS DRAWN ON
BUILDING ELEVATION
NUMBER
SHEET NUMBER
ELEVATION IS DRAWN ON
DETAIL NUMBER
SYMBOLS
STEEL & OTHER METAL PATTERN
CONCRETE BLOCK PATTERN
STONE CUT PATTERN
TERRA COTTA
CARPET AND PAD PATTERN
TILE, ACOUSTICAL
CEILING PATTERN
WOOD FLOORING PATTERN
BRICK PATTERN, GLAZED
SAND CLAY GRAVEL PATTERN
BRICK PATTERN
EROSION AND SEDIMENTATION
CONTROL, FILTRATION BED
PATTERN
EARTHWORK GRAVEL
PATTERN, POROUS FILL
EARTHWORK ROCK PATTERN
EARTHWORK PATTERN,
COMPACTED FILL PATTERN
RIPRAP PATTERN
SAND PATTERN
GLASS ELEVATION PATTERN
GYPSUM BOARD FINISH PATTERN
SEALANT AND BACKER ROD
INSULATION, RIGID
BOARD PATTERN
INSULATION, LOOSE
FILL PATTERN
WOOD FINISH PATTERN
PARTICLE BOARD PATTERN
ORIENTED STRAND BOARD PATTERN
WOOD, GLUED-LAMINATED PATTERN
WOOD FRAMING,
CONTINUOUS PATTERN
WOOD BLOCKING OR SHIM PATTERN
HATCH PATTERNS
EARTH, UNDISTURBED
PATTERN
EARTH, CRUSHED ROCK
GRAVEL PATTERN
EARTH, CRUSHED ROCK
GRAVEL PATTERN
PLYWOOD PATTERN
10 '-0"
Room name
B
M2
A1
AE101
A101
SIM
A1
AE101
CONCRETE POURED IN
PLACE, PRECAST
ALUMINUM PATTERN
ASPHALT SHINGLE PATTERN
KEYNOTE REFERENCE
BUILDING STRUCTURE
FIRESAFING INSUL
UL 1479/ASTM E814
FIRESTOP SEALANT
UL 723/ASTM E119
GYPSUM
WALLBOARD
PTN TYPE
VARIES - SEE
PLAN
PARTITION TOP ASSEMBLY
1HR / 2HR FIRE - RATED
ANSI\UL #263 DESIGN HWS001
PT-1
BUILDING STRUCTURE
FIRESAFING INSUL
UL 1479/ASTM E814
FIRESTOP SEALANT
UL 723/ASTM E119
(ONE SIDE ONLY)
GYPSUM
WALLBOARD
PTN TYPE
VARIES - SEE
PLAN
PARTITION TOP ASSEMBLY
30 MIN FIRE - RATED PT-1A
HC OCCUPANCY CORRIDOR
2 HOUR RATED FIRE & SMOKE PARTITION
2 HOUR RATED PARTITION
1 HOUR RATED PARTITION
LINETYPES
SMOKE ZONE BARRIER
SMOKE RESISTIVE ENCLOSURE
EXISTING LIFE SAFETY INFORMATION:
NEW WORK TO BE PERFORM IN THIS PROJECT WILL NOT HAVE AN
AFFECT ON THE EXISTING LIFE SAFETY ARRANGEMENT. NO
CHANGES TO TRAVEL PATHS OR RATED PARTITIONS ARE
ANTICIPATED.
EXISTING PARTITION LIFE SAFETY DESIGNATION SHOWN ON THESE
DRAWINGS HAS BEEN TRANSLATED FROM EXISTING FACILITY LIFE
SAFETY DRAWINGS PROVIDED BY THE VA.
PLEASE ALERT A/E IF DISCREPANCIES ARE FOUND IN THE FIELD.
ALL PENETRATIONS IS RATED PARTITIONS ARE TO BE PROVIDED
WITH APPROPRIATE FIRESTOPPING - SEE DETAILS BELOW.
ANNULAR FIRESTOPPING
THINKNESS REQUIREMENTS
TO COMPLY WITH
ANSI/UL263-DESIGN No.
FC7009 OR APPROVED
EQUIVALENT
STEEL FLANGES
DUCTWORK
ASSEMBLY VARIES SEE
ARCHITECTURAL PLANS &
DETAILS
FIRESEAL ON
FIRESAFING SYSTEM
WALL PENETRATION FIRESTOP
1HR / 2HR FIRE - RATED (FD N-REQD)
ANSI\UL #263 WL7009
WP- 1
DUCTWORK
ANNULAR FIRESTOPPING
THINKNESS
REQUIREMENTS TO
COMPLY WITH ANSI/UL263-
DESIGN No. WL1049 OR
APPROVED EQUIVALENT
ASSEMBLY VARIES SEE
ARCHITECTURAL PLANS &
DETAILS
METALLIC PIPE 6"
DIA OR SMALLER
FIRESEAL ON
FIRESAFING SYSTEMS
SEE SPECS
WALL PENETRATION FIRESTOP
1HR / 2HR FIRE - RATED
ANSI\UL #263 DESIGN WL1049
WP- 3
METALLIC PIPE 6" DIA
OR SMALLER
NOMINAL 3/8" FIRESTOP
SYSTEM (ANSI/UL 263 -
DESIGN CAJ-2124)
ASSEMBLY VARIES SEE
ARCHITECTURAL PLANS &
DETAILS
CLIP AND STEEL
ANCHOR
WALL PENETRATION FIRESTOP
2HR/3HR FIRE BARRIER
ANSI\UL #263 DESIGN DS1076
WP- 4
PLASTIC PIPE
FIRESTOP WRAP
STRIP SYSTEM
SCREW AND CLAMP
ELECTRICAL CONDUIT /
CABLE (SINGLE OR BUNDLE
UP TO 4 1/2" DIA)
ASSEMBLY VARIES SEE
ARCHITECTURAL PLANS &
DETAILS
ANNULAR FIRESTOPPING
THICKNESS REQUIREMENTS
TO COMPLY WITH
ANSI/UL263 DESIGN No.
WL3076 OR APPROVED
EQUIVALENT
WALL PENETRATION FIRESTOP
1HR / 2HR FIRE - RATED
ANSI\UL #263 DESIGN WL3076
WP- 5
NOTE:
ANNULUS RANGING
FROM POINT
CONTACT TO 2"
MAXIMUM
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :4 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
GI-002
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC04/30/2021
100% CONSTRUCTION
DOCUMENTS
SYMBOLS AND ABBREVIATIONS
FULLY SPRINKLERED
ARCHITECTURAL ABBREVIATIONS DRAWING AREA
ARCHITECTURAL SYMBOLS
1 1/2" = 1'-0"
1 PT-1 PARTITION TOP FIRESTOP
1 1/2" = 1'-0"
2 PT-1A PARTITION TOP FIRESTOP
1 1/2" = 1'-0"
3 WP-1 WALL PENETRATION FIRESTOP
1 1/2" = 1'-0"
4 WP-3 WALL PENETRATION FIRESTOP
1 1/2" = 1'-0"
6 WP-4 WALL PENETRATION FIRESTOP
1 1/2" = 1'-0"
5 WP-5 WALL PENETRATION FIRESTOP
ARCHITECTURAL SHEET LIST
Sheet Number Sheet Name
GI-002 SYMBOLS AND ABBREVIATIONS
AS100 BASEMENT LOCATION PLANS
AS101 FIRST FLOOR LOCATION PLANS
AS102 SECOND, THIRD & FORTH FLOOR LOCATION PLANS
AD101 ENLARGED RESTROOM DEMOLITION PLANS
AD102 ENLARGED RESTROOM DEMOLITION PLANS
AE101 ENLARGED NEW WORK RESTROOM FLOOR PLANS
AE102 ENLARGED NEW WORK RESTROOM FLOOR PLANS
AE111 ENLARGED RESTROOM REFLECTED CEILING PLANS
AE112 ENLARGED RESTROOM REFLECTED CEILING PLANS
AE201 INTERIOR ELEVATIONS
AE202 INTERIOR ELEVATIONS
AE203 INTERIOR ELEVATIONS
AE500 DOOR SCHEDULE / DETAILS & WALL TYPES
AE501 FINSH SCHEDULE & DETAILS
BLDG. 82
BLDG. 64
BLDG. 64-2
BLDG. 64
B64-2 - CB4
B64-2 - CB5
B L D G
B L D G
B82 - 168
AD101
Sim
AD101
Sim
D1/AD101 - DEMOLITION PLAN
D1/AE101 - NEW WORK PLAN
D1/AE111 - REFLECTED
CEILING PLAN
B7/AD101 - DEMOLITION PLAN
B7/AE101 - NEW WORK PLAN
B7/AE111 - REFLECTED
CEILING PLAN
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :3 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AS100
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
BASEMENT LOCATION PLANS
FULLY SPRINKLERED
3/64" = 1'-0"
1 BASEMENT LEVEL - BUILDING 64 & 82
D N
D N
R A M P
R A M P
U P
D N
S M O K
IN
G
S H E L T E R
U P
B L D G
F E C
D N
R A M P
D N
R A M P
D N
B L D G
B L D G
BLDG. 64-2
BLDG. 64
BLDG. 82
BLDG. 64
B L D G
B L D G
B-64 - A137
B-38 - 123
B-64-2 - C144
B-64-2 - C138J
B-19 - 113
B-82 - 168
B-64-2 - C136
B-64 - A127, A129 & A130
B-64-2 - C132
B5/AD102 - DEMOLITION PLAN
B5/AE102 - NEW WORK PLAN
B5/AE112 - REFLECTED
CEILING PLAN
AD102
Sim
AD102
Sim
D7/AD102 - DEMOLITION PLAN
D7/AE102 - NEW WORK PLAN
D7/AE112 - REFLECTED
CEILING PLAN
AD102
Sim
F7/AD102 - DEMOLITION PLAN
F7/AE102 - NEW WORK PLAN
F7/AE112 - REFLECTED
CEILING PLAN
AD101
Sim
F7/AD102 - DEMOLITION PLAN
F7/AE102 - NEW WORK PLAN
F7/AE112 - REFLECTED
CEILING PLAN
AD101
Sim
D3/AD101 - DEMOLITION PLAN
D3/AE101 - NEW WORK PLAN
D3/AE111 - REFLECTED
CEILING PLAN
AD101
Sim
F7/AD101 - DEMOLITION PLAN
F7/AE101 - NEW WORK PLAN
F7/AE111 - REFLECTED
CEILING PLAN
AD102
Sim
F5/AD102 - DEMOLITION PLAN
F5/AE102 - NEW WORK PLAN
F5/AE112 - REFLECTED
CEILING PLAN
AD102
Sim
B7/AD102 - DEMOLITION PLAN
B7/AE102 - NEW WORK PLAN
B7/AE112 - REFLECTED
CEILING PLAN
AD101
Sim
B7/AD101 - DEMOLITION PLAN
B7/AE101 - NEW WORK PLAN
B7/AE111 - REFLECTED
CEILING PLAN
B-62 - 113 & 113A
AD101
Sim
F5/AD101 - DEMOLITION PLAN
F5/AE101 - NEW WORK PLAN
F5/AE111 - REFLECTED
CEILING PLAN
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :4 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AS101
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
FIRST FLOOR LOCATION PLANS
FULLY SPRINKLERED
3/64" = 1'-0"
2 1ST FLOOR - BUILDING 19, 38, 64, 64-2, 82
3/64" = 1'-0"
1 1ST FLOOR - BUILDING 62
B-64 - B204
B-64 - C-237
B-82 - 366
BLDG. 82
BLDG. 64
AD102
Sim
D5/AD102 - DEMOLITION PLAN
D5/AE102 - NEW WORK PLAN
D5/AE112 - REFLECTED
CEILING PLAN
AD101
Sim
B3/AD101 - DEMOLITION PLAN
B3/AE101 - NEW WORK PLAN
B3/AE111 - REFLECTED
CEILING PLAN
AD101
Sim
D7/AD101 - DEMOLITION PLAN
D7/AE101 - NEW WORK PLAN
D7/AE111 - REFLECTED
CEILING PLAN
BLDG. 82
BLDG. 64
AD101
Sim
B1/AD101 - DEMOLITION PLAN
B1/AE101 - NEW WORK PLAN
B1/AE111 - REFLECTED
CEILING PLAN
B-82 - 481
B-64 - A401A B-64 - A443
AD101
Sim
F3/AD101 - DEMOLITION PLAN
F3/AE101 - NEW WORK PLAN
F3/AE111 - REFLECTED
CEILING PLAN
AD101
Sim
F1/AD101 - DEMOLITION PLAN
F1/AE101 - NEW WORK PLAN
F1/AE111 - REFLECTED
CEILING PLAN
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :4 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AS102
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
SECOND, THIRD & FORTH FLOOR
LOCATION PLANS
FULLY SPRINKLERED
3/64" = 1'-0"
3 2ND FLOOR - BUILDINGS 64 & 82
3/64" = 1'-0"
1 3RD FLOOR - BUILDING 82
3/64" = 1'-0"
2 4TH FLOOR - BUILDINGS 64
B
A
C-234
C-224
MEN'S
RESTROOM
B38-123
R4 R4
R4
R3
R3
R4R4
R1
R5
R2
R2
(MIN.CLEAR)
5' - 0"
R10
R9
R8
R8
R4
R4
R3
R4
R7
B62-113
MEN'S
RESTROOM
R4 R4
R4
R3
R1
R1
R2
R2
(MIN. CLEAR)
5' - 0"
R9
UNISEX
RESTROOM
B64-A401A
R4
R4
R8R8
R9
WAITING
B64-A401
R1 R2
R14
(5 '-0 M
IN
C L E A R
R4R4
R11
R10
B64-A443
RESTROOM
B64-A444
B64-A444B
RESTROOM
R9
R9
WAITING
B64-A444A
R8
R8
R14
R9
R1
R1
(5'-0" MIN. CLEAR)
6' - 0"
MEN'S
RESTROOM
B64-C237
R4 R4
R2
R5
R3
R4
R1
R9
R7
R4
R4 R4 R4
R2
(M
IN
C L E A R
TOILET
B64-2-138J
R4
R4
R1
R2
R4
R4 R1
R2
R9
R8 R7 R7
B64-2-138L
STAFF
(M
IN
C L E A R
B64-2-138M
HAC
R7
R1
R9
R4
R8
R9
RESTROOM
B64-2-C144
R4
R4
R1
R2
CORRIDOR
B64A-C1-19
(5'-0" MIN. CLEAR)
5' - 9" R9
MEN
B64-2-CB4
WOMEN
B64-2-CB5
R4
R3
R4
R4
R3
R10
R1
R2
R4
R4
R1
R2
R8 R8
(5'-0" MIN. CLEAR)
5' - 6"
(5'-0" MIN. CLEAR)
5' - 6"
R9
R9
R4 R4 R4
R1
MEN'S
RESTROOM
B82-258
R8
WOMEN
B82-259
R2
(5'-0" MIN. CLEAR)
5' - 6"
R9
R4
R4 R4
R1
MEN'S
RESTROOM
B82-366
WOMEN
B82-368
R8
R2
(5'-0" MIN. CLEAR)
5' - 6"
R9 R1
R4
R4MEN'S
RESTROOM
B82-481
WOMEN
B82-482
R8
R2
(5'-0" MIN. CLEAR)
5' - 6"
R9
GENERAL DEMOLITION NOTES:
1. GENERAL CONTRACTOR (GC) SHALL FIELD VERIFY & REPORT EXISTING
CONDITIONS AND DIMENSIONS PRIOR TO REMOVALS. IF DISCREPANCIES ARE FOUND.
GC TO NOTIFY ARCHITECT FOR CLARIFICATION BEFORE COMMENCING WITH THE
WORK.
2. GC AND SUBCONTRACTORS (SC) FOR EACH TRADE ARE ADVISED THAT
INFORMATION PERTINENT TO THEIR WORK MAY BE INDICATED OR DESCRIBED IN
OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
3. REFER TO SPECIFIC DRAWINGS FOR PLUMBING, HVAC AND ELECTRICAL
REMOVALS WORK.
4. GC AND SC ARE RESPONSIBLE FOR PROVIDING ALL REMOVALS AND PATCHING
REQUIRED TO COMPLETE THEIR WORK IN ACCORDANCE WITH THE DESIGN INTENT.
5. THESE REMOVALS DRAWINGS HAVE BEEN PREPARED BASED UPON EXISTING
CONSTRUCTION DOCUMENT DRAWINGS AND FIELD OBSERVATIONS. THE EXACT
LOCATION OF THE BUILDING STRUCTURAL ELEMENTS (COLUMNS, BEAMS, LOAD
BEARING WALLS, ETC.) MAY BE DIFFERENT IN THE FIELD THAN WHAT IS INDICATED OR
ASSUMED ON THESE DRAWINGS. GC SHALL FIELD VERIFY THE LOCATION OF ALL
BUILDING STRUCTURAL ELEMENTS. ALL BUILDING STRUCTURAL ELEMENTS SHALL
REMAIN UNLESS INDICATED TO BE REMOVED ON THE STRUCTURAL DRAWINGS. ANY
BUILDING STRUCTURAL ELEMENT INDICATED AS BEING REMOVED ON THIS DRAWING
SHALL BE CONFIRMED WITH THE ARCHITECT PRIOR TO COMMENCING REMOVALS
6. GC SHALL PROTECT, REPLACE OR REPAIR ANY EXISTING CONSTRUCTION
SCHEDULED TO REMAIN WHICH IS DAMAGED DURING REMOVALS
7. GC SHALL PROVIDE REQUIRED SHORING OR TEMPORARY BRACING DURING
REMOVALS
8. REMOVE EXISTING CEILINGS AND SUPPORTS WHERE NEW CEILINGS ARE
SCHEDULED IN THE ROOM FINISH SCHEDULE.
9. REMOVE PARTITIONS, FIXTURES, TOILET ACCESSORIES, SHELVING, CABINETRY
AND ALL MISCELLANEOUS ITEMS SHOWN WITH DASHED LINES.
10. PATCH ALL FLOORS, WALLS, BASE AND CEILINGS WHERE PARTITIONS OR
MISCELLANEOUS ITEMS ARE REMOVED.
11. REMOVE DOORS, FRAMES AND SIDELIGHTS SHOWN WITH DASHED LINES,
UNLESS OTHERWISE NOTED.
12. REMOVE TOILET PARTITIONS AND GRAB BARS SHOWN WITH DASHED LINES.
REPAIR EXISTING CONSTRUCTION SCHEDULED TO REMAIN.
13. REMOVE EXISTING FLOR AND WALL TILE WHERE NEW IS SCHEDULED IN THE
ROOM FINISH SCHEDULE AND PREPARE EXISTING FLOOR AND WALL SURFACES TO
RECEIVE NEW FINISHES.
14. CONTRACTOR SHALL VERIFY WITH THE OWNER THOSE REMOVED ITEMS TO BE
TURNED OVER TO THE OWNER.
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
NEW PARTITION (SEE PARTITION
TYPES FOR ADDITIONAL INFO.)
TEMPORARY PARTITION
NOTES:
TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION
REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY
PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS
AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.
PARTITION LEGEND:
MEN'S
RESTROOM
B82-168
R4 R4 R4
R1
WOMEN
B82-167
R8
R2
(5'-0" MIN. CLEAR)
5' - 6"
R9
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :1 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AD101
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
ENLARGED RESTROOM
DEMOLITION PLANS
FULLY SPRINKLERED
1/4" = 1'-0" AS101
3 DEMOLITION PLAN B38 - RM 123
1/4" = 1'-0" AS101
6 DEMOLITION PLAN B62 - RM 113
1/4" = 1'-0" AS102
12 DEMOLITION PLAN B64 - RM A401A
1/4" = 1'-0" AS102
9 DEMOLITION PLAN B64 - RM A444
1/4" = 1'-0" AS102
2 DEMOLITION PLAN B64 - RM C237
1/4" = 1'-0" AS101
5 DEMOLITION PLAN B64-2 - RM C138J, C138L & C138M
1/4" = 1'-0" AS101
8 DEMOLITION PLAN B64-2 - RM C144
1/4" = 1'-0" AS100
11 DEMOLITION PLAN B64-2 - RMS CB4 & CB5
1/4" = 1'-0"
4 DEMOLITION PLAN B82 - RM 258
1/4" = 1'-0" AS102
7 DEMOLITION PLAN B82 - RM 366
1/4" = 1'-0" AS102
10 DEMOLITION PLAN B82 - RM 481
R1 REMOVE ALL FINISHES, INCLUDING TILE FLOORING, TILE WAINSCOT, ACT OR
GYPSUM CEILINGS. SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION.
R2 REMOVE ALL EXISTING TOILET ACCESSORIES.
R3 REMOVE ALL EXISTING TOILET PARTITIONS.
R4 REMOVE EXISTING PLUMBING FIXTURES - SEE PLUMBING DRAWINGS FOR
ADDITIONAL INFORMATION.
R5 REMOVE EXISTING CUBICLE CURTAIN AND TRACK.
R7 SLECTIVLY REMOVE PORTION OF EXISTING WALL TO PREPARE FOR
INSTATLLATION OF NEW DOOR AND FRAME - REFER TO NEW WORK PLANS FOR
ADDITIONAL INFORMATION.
R8 REMOVE EXISTING WALL SHOWN DASHED.
R9 REMOVE EXISTING DOOR AND FRAME.
R10 REMOVE EXISTING CASEWORK SHOWN DASHED.
R11 REMOVE EXISTING SHOWER FIXTURES AND ACCESSORIES.
R14 APPROXIMATE EXTENTS OF EXISTING VCT FLOORING OUTSIDE OF RESTROOM
REQUIRED TO BE DEMOLISHED TO EXPAND RESTROOM FOOTPRINT - REFER TO
NEW WORK PLANS FOR ADDITIONAL INFORMATION.
KEYNOTES
1/4" = 1'-0" AS100
1 DEMOLITION PLAN B82 - RM 168
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
NEW PARTITION (SEE PARTITION
TYPES FOR ADDITIONAL INFO.)
TEMPORARY PARTITION
NOTES:
TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION
REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY
PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS
AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.
PARTITION LEGEND:
GENERAL DEMOLITION NOTES:
1. GENERAL CONTRACTOR (GC) SHALL FIELD VERIFY & REPORT EXISTING
CONDITIONS AND DIMENSIONS PRIOR TO REMOVALS. IF DISCREPANCIES ARE FOUND.
GC TO NOTIFY ARCHITECT FOR CLARIFICATION BEFORE COMMENCING WITH THE
WORK.
2. GC AND SUBCONTRACTORS (SC) FOR EACH TRADE ARE ADVISED THAT
INFORMATION PERTINENT TO THEIR WORK MAY BE INDICATED OR DESCRIBED IN
OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
3. REFER TO SPECIFIC DRAWINGS FOR PLUMBING, HVAC AND ELECTRICAL
REMOVALS WORK.
4. GC AND SC ARE RESPONSIBLE FOR PROVIDING ALL REMOVALS AND PATCHING
REQUIRED TO COMPLETE THEIR WORK IN ACCORDANCE WITH THE DESIGN INTENT.
5. THESE REMOVALS DRAWINGS HAVE BEEN PREPARED BASED UPON EXISTING
CONSTRUCTION DOCUMENT DRAWINGS AND FIELD OBSERVATIONS. THE EXACT
LOCATION OF THE BUILDING STRUCTURAL ELEMENTS (COLUMNS, BEAMS, LOAD
BEARING WALLS, ETC.) MAY BE DIFFERENT IN THE FIELD THAN WHAT IS INDICATED OR
ASSUMED ON THESE DRAWINGS. GC SHALL FIELD VERIFY THE LOCATION OF ALL
BUILDING STRUCTURAL ELEMENTS. ALL BUILDING STRUCTURAL ELEMENTS SHALL
REMAIN UNLESS INDICATED TO BE REMOVED ON THE STRUCTURAL DRAWINGS. ANY
BUILDING STRUCTURAL ELEMENT INDICATED AS BEING REMOVED ON THIS DRAWING
SHALL BE CONFIRMED WITH THE ARCHITECT PRIOR TO COMMENCING REMOVALS
6. GC SHALL PROTECT, REPLACE OR REPAIR ANY EXISTING CONSTRUCTION
SCHEDULED TO REMAIN WHICH IS DAMAGED DURING REMOVALS
7. GC SHALL PROVIDE REQUIRED SHORING OR TEMPORARY BRACING DURING
REMOVALS
8. REMOVE EXISTING CEILINGS AND SUPPORTS WHERE NEW CEILINGS ARE
SCHEDULED IN THE ROOM FINISH SCHEDULE.
9. REMOVE PARTITIONS, FIXTURES, TOILET ACCESSORIES, SHELVING, CABINETRY
AND ALL MISCELLANEOUS ITEMS SHOWN WITH DASHED LINES.
10. PATCH ALL FLOORS, WALLS, BASE AND CEILINGS WHERE PARTITIONS OR
MISCELLANEOUS ITEMS ARE REMOVED.
11. REMOVE DOORS, FRAMES AND SIDELIGHTS SHOWN WITH DASHED LINES,
UNLESS OTHERWISE NOTED.
12. REMOVE TOILET PARTITIONS AND GRAB BARS SHOWN WITH DASHED LINES.
REPAIR EXISTING CONSTRUCTION SCHEDULED TO REMAIN.
13. REMOVE EXISTING FLOR AND WALL TILE WHERE NEW IS SCHEDULED IN THE
ROOM FINISH SCHEDULE AND PREPARE EXISTING FLOOR AND WALL SURFACES TO
RECEIVE NEW FINISHES.
14. CONTRACTOR SHALL VERIFY WITH THE OWNER THOSE REMOVED ITEMS TO BE
TURNED OVER TO THE OWNER.
R8R8
R9
R9
R10
R4
R4
R3
R3
R4
R4
R4
R4
R3
R9
R7
R7
R1
R2
B64-A130
LACTATION
B64-A129
RESTROOM
B64-A127
RESTROOM
R1
R2
R1
R2
WAITING
B64-A125
R2
R2
MEN
B64-C136
WOMEN
B64-C135
R4
R4
R4
R4
R4
R3
R1
R2
R4
CORRIDOR
B64-C1-9
R9
101 SF
BLOOD SPEC.
B64-2-C131
R4R4
R9
R9
R4R4
R8
R1
R2
R1
R2
B64-2-C132
TOILET
B64-2-C133
TOILET
R1
WAITING
B64-2-C1-2
R6 R12R12
MEN'S
RESTROOM
B19-113
R4
R4
R2
R1 R3
R13
CORRIDOR
B19-C1-7
R9
MEN
B64-B204
R1 R4 R4
R4
R9
R7
R2
R3R3
(5'-0" MIN. CLEAR)
6' - 0"
MEN'S
RESTROOM
B64-A137
R2
R3
R4
R4
R2 R2
R4
R2
R4
R1
(5 M
IN
C L E A R
R9
R15
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :1 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AD102
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
ENLARGED RESTROOM
DEMOLITION PLANS
FULLY SPRINKLERED
R1 REMOVE ALL FINISHES, INCLUDING TILE FLOORING, TILE WAINSCOT, ACT OR
GYPSUM CEILINGS. SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION.
R2 REMOVE ALL EXISTING TOILET ACCESSORIES.
R3 REMOVE ALL EXISTING TOILET PARTITIONS.
R4 REMOVE EXISTING PLUMBING FIXTURES - SEE PLUMBING DRAWINGS FOR
ADDITIONAL INFORMATION.
R6 REMOVE WALL AS SHOWN TO CREATE NEW WALL OPENING - REFER TO NEW
WORK PLANS FOR ADDITIONAL INFORMATION.
R7 SLECTIVLY REMOVE PORTION OF EXISTING WALL TO PREPARE FOR
INSTATLLATION OF NEW DOOR AND FRAME - REFER TO NEW WORK PLANS FOR
ADDITIONAL INFORMATION.
R8 REMOVE EXISTING WALL SHOWN DASHED.
R9 REMOVE EXISTING DOOR AND FRAME.
R10 REMOVE EXISTING CASEWORK SHOWN DASHED.
R12 EXTENTS OF EXISTING FLOORING TO BE REMOVED - REFER TO NEW WORK PLANS
FOR ADDITIONAL INFORMATION.
R13 EXISTING ELECTRICAL PANEL TO REMAIN - SEE ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
R15 REMOVE EXISTING RADIATOR UNIT - SEE MECHANICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
KEYNOTES
1/4" = 1'-0" AS101
1 DEMOLITION PLAN B64 - RM A127, A129, & A130
1/4" = 1'-0" AS101
3 DEMOLITION PLAN B64 - RM C136
1/4" = 1'-0" AS101
2 DEMOLITION PLAN B64-2 - RM C132 & C133
1/4" = 1'-0" AS101
4 DEMOLITION PLAN B19 - RM 113
1/4" = 1'-0" AS102
5 DEMOLITION PLAN B64 - RM B204
1/4" = 1'-0" AS101
6 DEMOLITION PLAN B64 - RM A137
GENERAL NOTES:
1. ALL WALL PARTITION TYPES ARE M4 UNLESS NOTED OTHERWISE. SEE SHEET AE500
FOR PARTITION TYPES.
2. REFER TO GI002 SHEET FOR ALL ABBREVIATIONS AND SYMBOLS.
3. REFER TO ALL DRAWINGS INCLUDING ARCHITECTURAL, MECHANICAL, PLUMBING,
AND ELECTRICAL DRAWINGS FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS, AND
SYMBOLS.
4. VERIFY ALL EQUIPMENT OPENINGS & RECOMMENDATIONS. LOCATION AND SIZES
SHOWN ARE FOR INTENT PURPOSES ONLY. ADJUST ROUGH OPENINGS AND
LOCATIONS AS REQUIRED PER ACTUAL EQUIPMENT.
5. DOOR JAMBS ARE 4" FROM NEAREST ADJACENT INTERSECTING PARTITION UNLESS
NOTED OTHERWISE. SEE DOOR DETAILS FOR FURTHER INFORMATION
6. G.C. TO PROVIDE & INSTALL ALL IN-WALL OR IN-CEILING BLOCKING / BRACING AS
REQUIRED FOR ALL MILLWORK ITEMS, EQUIPMENT, SHELVING, AND ACCESSORIES
WHETHER ITEMS ARE BY G.C. OR OTHERS COORDINATE WITH OWNER
7. G.C. SHALL BE RESPONSIBLE FOR LAYING OUT THE SPACE PRIOR TO COMMENCING
WORK AND SHALL NOTIFY THE ARCHITECT AND OWNER OF ANY DISCREPANCIES.
8. REFER TO SHEET AE500 FOR DOOR SCHEDULE AND FRAMING TYPES.
9. ALL INTERIOR DIMENSIONS SHOWN ARE TO FACE OF FRAMING UNLESS
SPECIFICALLY NOTED OTHERWISE.
10. ALL DRAWINGS ARE OF EQUAL IMPORTANCE IN DEFINING THE WORK OF THE
CONTRACT DOCUMENTS. CONTRACTORS SHALL REVIEW ALL DRAWINGS BEFORE THE
INSTALLATION OF THEIR WORK. SHOULD THERE BE A DISCREPANCY WITHIN AND
BETWEEN THE DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER
INSTALLATION NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO INSTALLATION OF
SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL
DRAWINGS, SHALL BE CORRECTED BY CONTRACTOR AT THEIR EXPENSE AND AT NO
ADDITIONAL COST TO THE OWNER OR ARCHITECT.
11. DO NOT SCALE DRAWINGS, THE DRAWINGS ARE NOT NECESSARILY TO SCALE -
USE GIVEN DIMENSIONS. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF
DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT FOR CLARIFICATION BEFORE
COMMENCING THE WORK.
12. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE
SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED
CONSULT ARCHITECT BEFORE PROCEEDING WITH THE WORK.
13. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE, UNLESS OTHERWISE
NOTED.
14. REFER TO MECHANICAL AND ELECTRICAL CONTRACTORS DRAWINGS AND
MANUFACTURES TEMPLATE DRAWINGS FOR ALL MECHANICAL AND ELECTRICAL
EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATIONS, SPRING ISOLATION,
ETC. NOT SHOWN ON THE DRAWINGS
15. OWNER FURNISHED ITEMS THE G.C. SHALL COORDINATE AND PROVIDE
ELECTRICAL, PLUMBING, AND MECHANICAL CONNECTIONS FOR ALL EQUIPMENT.
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
NEW PARTITION (SEE PARTITION
TYPES FOR ADDITIONAL INFO.)
TEMPORARY PARTITION
NOTES:
TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION
REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY
PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS
AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.
PARTITION LEGEND:
178 SF
MEN'S
RESTROOM
B38-123
AE201
9d
9a
9b
9c
MIN. CLEAR
5' - 0"
TBA-3
TBA-2
TBA-1
TBA-4
TBA-3
TBA-2
TBA-1
TBA-4
F3
F3
B38-123
M4A
M4A
F3
114 SF
WOMEN'S
RESTROOM
B62-113A
124 SF
MEN'S
RESTROOM
B62-113
AE201
3c
3a
3b
3d
AE201
8b
8c
8d
8a
B62-113F2F2
MIN. CLEAR
5' - 0"M4A
M4A
TBA-8
TBA-8 ALIGN
ALIGN
MA2
TBA-1
TBA-7
TBA-4
TBA-3 TBA-2
TBA-3
TBA-2
TBA-4
TBA-1
B62-113A
MA2
MA2
148 SF
MEN'S
RESTROOM
B64-C237
AE202
8d
8a
8b
8c
F1
B -C
M
IN
C L E A R
F3
F3 F3
TBA-3
TBA-2
TBA-1
TBA-4
TBA-8
TBA-2 TBA-2
TBA-3
TBA-3
1' - 0"
60 SF
UNISEX
RESTROOM
B64-A401A
AE202
10b
10c
10d
10a
B64-A401A
WAITING
B64-A401
(5 M
IN
C L E A R
M4A
M4
M4
M4AM4A
TBA-2
TBA-3
TBA-1
TBA-7
TBA-4
8' - 0"
(5'-0" MIN. CLR)
5' - 10"
AE202
9b
9c
9d
9a
61 SF
RESTROOM
B64-A444
WAITING
B64-A444A
B -A
B64-A444A
(5'-0" MIN. CLEAR)
6' - 0" M4A
M4A
M4
TBA-2
TBA-3
TBA-1
TBA-4TBA-7
F1
F1
M4A
M4A
61 SF
WOMEN
B64-2-CB5
100 SF
MEN
B64-2-CB4
AE202
1b
1a 1c
1d
AE2026a
6b
6c
6d
B64-2-CB4
B64-2-CB5
(5'-0" MIN. CLEAR)
5' - 6"
(5'-0" MIN. CLEAR)
5' - 6"
M4A
TBA-4
TBA-4
TBA-1
TBA-3
TBA-2
TBA-2
TBA-3
TBA-1
TBA-7
60 SF
TOILET
B64-2-138J
AE202 7c
7b
7a
7d
(M
IN
C L E A R
61 SF
STAFF
B64-2-138L
2' - 0" 8' - 7" 9' - 9"
AE202
3d
3a
3b
3c
F1 F1
10"
B -2 -C L
B -2 -C J
M6
MA2MA2
M4A M4A
M4A
TBA-3
TBA-2
TBA-8
TBA-4
TBA-7
TBA-1
TBA-1
TBA-4
TBA-3
TBA-2
57 SF
RESTROOM
B64-2-C144
AE202
2b
2c
2d
2aB64-2-C144
5'-0" MIN. CLR
5' - 9"
TBA-2
TBA-3
TBA-4
TBA-1
AE201
2b
2c
2d
2a
60 SF
MEN'S
RESTROOM
B82-258
B82-259
WOMEN
(5'-0" MIN. CLEAR)
5' - 6"
B82-258
M4A
TBA-3TBA-2
TBA-1
TBA-4
AE201
1b
1a
1d
1c
60 SF
MEN'S
RESTROOM
B82-366
B82-368
WOMEN
(5'-0" MIN. CLEAR)
5' - 6"
M4A
B82-336
TBA-3
TBA-1
TBA-4
TBA-2
AE201
6b
6c
6d
6a
60 SF
MEN'S
RESTROOM
B82-481
B82-481
B82-482
WOMEN
(5'-0" MIN. CLEAR)
5' - 6"
M4A
TBA-3TBA-2
TBA-4
TBA-1 AE201
7b
7c
7d
7a
60 SF
MEN'S
RESTROOM
B82-168
B82-167
WOMEN
(5'-0" MIN. CLEAR)
5' - 6"
M4A
B82-168
TBA-4
TBA-2
TBA-1
TBA-3
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :3 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AE101
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
ENLARGED NEW WORK
RESTROOM FLOOR PLANS
FULLY SPRINKLERED
F1 INFILL EXISTING DOOR OPENING TO MATCH EXISTING ADJACENT WALL
CONSTRUCITON.
F2 INFILL EXISTING WALL OPENING TO CREATE A FLUSH WALL TO RECIEVE NEW
FINISHES, BOTH SIDES OF THE WALL.
F3 TOILET PARTITION
KEYNOTES:
1/4" = 1'-0"
3 NEW FLOOR PLAN B38 - RM 123
1/4" = 1'-0"
6 NEW FLOOR PLAN B62 - RMS 113 & 113A
1/4" = 1'-0"
2 NEW FLOOR PLAN B64 - RM C237
1/4" = 1'-0"
12 NEW FLOOR PLAN B64 - RM A401A
1/4" = 1'-0"
9 NEW FLOOR PLAN B64 - RM A443 & A444B
1/4" = 1'-0"
11 NEW FLOOR PLAN B64-2 - RM CB4 & CB5
1/4" = 1'-0"
5 NEW FLOOR PLAN B64-2 - RMS C138J & C138L
1/4" = 1'-0"
8 NEW FLOOR PLAN B64-2 - RM C144
1/4" = 1'-0"
4 NEW FLOOR PLAN B82 - RM 258
1/4" = 1'-0"
7 NEW FLOOR PLAN B82 - RM 366
1/4" = 1'-0"
10 NEW FLOOR PLAN B82 - RM 481
1/4" = 1'-0"
1 NEW FLOOR PLAN B82 - RM 168
BLOOD SPEC.
B64-2-C131
61 SF
UNISEX
B64-C132
AE203
1a
1c
1d 1b
E.T. / 2
B64-C114
ELEC.
B64-C118
E.T. / 9
B64-C120 E.T. / 10
B64-C128
SATELLITE LAB
B64-C130
E.T. / 1
B64-C113
WAITING
B64-2-C1-2
B -C
M4AM4A
M4M4
TBA-8
TBA-2
TBA-1
TBA-7
TBA-3
/8
4' - 2"
60 SF
WOMEN
B64-A127
55 SF
LACTATION
B64-A129
60 SF
MEN
B64-A130 AE203 5b5d
5a
5c
AE203
3a
3c
3b3d
AE2034d
4c
4b
4a
5' - 0"
6' - 6" 10"
F1
F1
WAITING
B64-A125
B64-A127
B64-A129
B -A
TBA-2
TBA-3
TBA-4
TBA-1
TBA-7
TBA-8
TBA-2
TBA-3
TBA-2
TBA-8
TBA-4
TBA-1
TBA-3
M4
M4A M4A
M4
M4
M4A
M4A
145 SF
MEN
B64-C136
123 SF
WOMEN
B64-C135
AE203
2d 2c
2b2a
B64-C136
TBA-2
TBA-1TBA-4
TBA-2
TBA-3
TBA-3
F3
F3
F3
TBA-3
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
NEW PARTITION (SEE PARTITION
TYPES FOR ADDITIONAL INFO.)
TEMPORARY PARTITION
NOTES:
TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION
REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY
PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS
AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.
PARTITION LEGEND:
GENERAL NOTES:
1. ALL WALL PARTITION TYPES ARE M4 UNLESS NOTED OTHERWISE. SEE SHEET AE500
FOR PARTITION TYPES.
2. REFER TO GI002 SHEET FOR ALL ABBREVIATIONS AND SYMBOLS.
3. REFER TO ALL DRAWINGS INCLUDING ARCHITECTURAL, MECHANICAL, PLUMBING,
AND ELECTRICAL DRAWINGS FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS, AND
SYMBOLS.
4. VERIFY ALL EQUIPMENT OPENINGS & RECOMMENDATIONS. LOCATION AND SIZES
SHOWN ARE FOR INTENT PURPOSES ONLY. ADJUST ROUGH OPENINGS AND
LOCATIONS AS REQUIRED PER ACTUAL EQUIPMENT.
5. DOOR JAMBS ARE 4" FROM NEAREST ADJACENT INTERSECTING PARTITION UNLESS
NOTED OTHERWISE. SEE DOOR DETAILS FOR FURTHER INFORMATION
6. G.C. TO PROVIDE & INSTALL ALL IN-WALL OR IN-CEILING BLOCKING / BRACING AS
REQUIRED FOR ALL MILLWORK ITEMS, EQUIPMENT, SHELVING, AND ACCESSORIES
WHETHER ITEMS ARE BY G.C. OR OTHERS COORDINATE WITH OWNER
7. G.C. SHALL BE RESPONSIBLE FOR LAYING OUT THE SPACE PRIOR TO COMMENCING
WORK AND SHALL NOTIFY THE ARCHITECT AND OWNER OF ANY DISCREPANCIES.
8. REFER TO SHEET AE500 FOR DOOR SCHEDULE AND FRAMING TYPES.
9. ALL INTERIOR DIMENSIONS SHOWN ARE TO FACE OF FRAMING UNLESS
SPECIFICALLY NOTED OTHERWISE.
10. ALL DRAWINGS ARE OF EQUAL IMPORTANCE IN DEFINING THE WORK OF THE
CONTRACT DOCUMENTS. CONTRACTORS SHALL REVIEW ALL DRAWINGS BEFORE THE
INSTALLATION OF THEIR WORK. SHOULD THERE BE A DISCREPANCY WITHIN AND
BETWEEN THE DRAWINGS THAT WOULD CAUSE AN AWKWARD OR IMPROPER
INSTALLATION NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO INSTALLATION OF
SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL
DRAWINGS, SHALL BE CORRECTED BY CONTRACTOR AT THEIR EXPENSE AND AT NO
ADDITIONAL COST TO THE OWNER OR ARCHITECT.
11. DO NOT SCALE DRAWINGS, THE DRAWINGS ARE NOT NECESSARILY TO SCALE -
USE GIVEN DIMENSIONS. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AT THE JOB SITE PRIOR TO THE START OF CONSTRUCTION. IF
DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT FOR CLARIFICATION BEFORE
COMMENCING THE WORK.
12. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE SHOWN. WHERE
SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT CANNOT BE DETERMINED
CONSULT ARCHITECT BEFORE PROCEEDING WITH THE WORK.
13. FINISH FLOOR ELEVATIONS ARE TO TOP OF CONCRETE, UNLESS OTHERWISE
NOTED.
14. REFER TO MECHANICAL AND ELECTRICAL CONTRACTORS DRAWINGS AND
MANUFACTURES TEMPLATE DRAWINGS FOR ALL MECHANICAL AND ELECTRICAL
EQUIPMENT SUPPORTS, BOLT SETTING TEMPLATES, ISOLATIONS, SPRING ISOLATION,
ETC. NOT SHOWN ON THE DRAWINGS
15. OWNER FURNISHED ITEMS THE G.C. SHALL COORDINATE AND PROVIDE
ELECTRICAL, PLUMBING, AND MECHANICAL CONNECTIONS FOR ALL EQUIPMENT.
69 SF
MEN'S
RESTROOM
B19-113
AE201
4b
4a
4d
4c
CORRIDOR
B19-C1-7
B -1
F5TBA-2
TBA-1
TBA-4
TBA-3
69 SF
MEN
B64-B204 AE202
4a
4c
4b
4d
(5'-0" MIN. CLEAR)
6' - 0" 3' - 0"
B64-B204
TBA-2
TBA-3
TBA-4
TBA-1
EXISTING RESTROOM B204 IS TOO
NARROW TO ACCOMMODATE VA
REQUIRED TURNING RADIUS, OMIT
HANDICAPPED SIGNAGE ON DOOR
119 SF
MEN'S
RESTROOM
B64-A137
AE2025a
5b
5c
5d
(5 M
IN
C L E A R
TBA-1
TBA-4
TBA-8
TBA-2
TBA-3
B -A
F3
F3
/8 "2
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :3 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AE102
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
ENLARGED NEW WORK
RESTROOM FLOOR PLANS
FULLY SPRINKLERED
F1 INFILL EXISTING DOOR OPENING TO MATCH EXISTING ADJACENT WALL
CONSTRUCITON.
F3 TOILET PARTITION
F5 EXISTING ELECTRICAL PANEL TO REMAIN - SEE ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION.
KEYNOTES:
1/4" = 1'-0"
2 NEW FLOOR PLAN B64 - RM C132
1/4" = 1'-0"
1 NEW FLOOR PLAN B64 - RM A127, A129, & A130
1/4" = 1'-0"
3 NEW FLOOR PLAN B64 - RM C136
1/4" = 1'-0"
4 NEW FLOOR PLAN B19 - RM 113
1/4" = 1'-0"
5 NEW FLOOR PLAN B64 - RM B204
1/4" = 1'-0"
6 NEW FLOOR PLAN B64 - RM A137
MEN'S
RESTROOM
B38-123 8' - 0"ACP-1
WOMEN'S
RESTROOM
B62-113A
MEN'S
RESTROOM
B62-113
8' - 0"ACP-1
8' - 0"ACP-1
MEN'S
RESTROOM
B64-C237 8' - 0"ACP-1
NEW CUBICAL TRACK
AND CURTAIN
UNISEX
RESTROOM
B64-A401A
8' - 0"ACP-1
RESTROOM
B64-A444
8' - 0"ACP-1
MEN
B64-2-CB4
WOMEN
B64-2-CB5
8' - 0"ACP-1
8' - 0"ACP-1
TOILET
B64-2-138J
8' - 0"ACP-1
8' - 0"ACP-1
STAFF
B64-2-138L
RESTROOM
B64-2-C144
8' - 0"ACP-1
MEN'S
RESTROOM
B82-258 8' - 0"ACP-1
8' - 0"ACP-1
MEN'S
RESTROOM
B82-366
8' - 0"ACP-1
MEN'S
RESTROOM
B82-481
CEILING LEGEND
GWB ATTACHED
TO HM STUD
REFLECTED CEILING PLAN NOTES:
1. ALL CEILINGS TO BE 8'-0" AFF UNLESS NOTED OTHERWISE.
2. REFER TO SHEET GI002 FOR ALL ABBREVIATIONS
3. CONTRACTOR TO VERIFY LOCATIONS OF MAIN CEILING TEES BEFORE
PROCEEDING WITH FIXTURE INSTALLATION. NOTIFY ARCHITECT OF
INTERFERENCES.
4. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL
REFLECTED CEILING PLANS AND ELECTRICAL LIGHTING PLANS PRIOR TO
CONSTRUCTION.
5. REFER TO ELECTRICAL PLANS FOR LOCATIONS OF STROBES AND EXIT SIGNS.
6. ALL CEILING GRILLES, TRIM EDGES AND SLOT DIFFUSERS TO MATCH ADJACENT
CEILING COLOR.
7. ALL SPRINKLER HEADS TO OCCUR AT CENTER OF TILES.
8. LAYOUT TILES AS SHOWN IN REFLECTED CEILING PLANS.
9. REFER TO SPECIFICATIONS FOR ALL ACOUSTICAL PANEL CEILING TYPES.
10. SEE AS501 SHEETS FOR ROOM FINISH SCHEDULE FOR CEILING FINISH
INFORMATION.
11. WHERE NO CEILING MATERIAL IS SHOWN THE STRUCTURE ABOVE IS TO BE
EXPOSED, U.N.O.
12. SEE EL SHEETS FOR CONTINUED LIGHTING INFORMATION
13. SEE MH SHEETS FOR CONTINUED MECHANICAL INFORMATION.
ELECTRICAL SYMBOLS INDICATING LIGHTING LOCATIONS.
REFER TO EL SHEETS FOR SIZE/ TYPE OF LIGHTING FIXTURE
MECHANICAL SYMBOLS INDICATING SUPPLY DIFFUSER OR
EXHAUST/ RETURN GRILLE LOCATIONS. REFER TO MH
SHEETS FOR SIZE/ TYPE OF DIFFUSER/ GRILLE.
ACOUSTICAL TILE CEILING
2'-0" x 2'-0" ON METAL
SUSPENSION GRID
NO HATCH SHOWN
INDICATES EXISTING CEILING
TO REMAIN, UNLESS NOTED
OTHERWISE
SPRINKLER HEAD LOCATIONS - SEE FP DRAWINGS FOR
ADDITIONAL INFORMATIN
ROOM OCCUPANCY SENSOR - SEE ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
NEW PARTITION (SEE PARTITION
TYPES FOR ADDITIONAL INFO.)
TEMPORARY PARTITION
NOTES:
TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION
REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY
PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS
AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.
PARTITION LEGEND:
MEN'S
RESTROOM
B82-168
8' - 0"ACP-1
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :4 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AE111
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
ENLARGED RESTROOM
REFLECTED CEILING PLANS
FULLY SPRINKLERED
1/4" = 1'-0"
3 REFLECTED CEILING PLAN B38 - RM 123
1/4" = 1'-0"
6 REFLECTED CEILING PLAN B62 - RM 113 & 113A
1/4" = 1'-0"
2 REFLECTED CEILING PLAN B64 - RM C237
1/4" = 1'-0"
12 REFLECTED CEILING PLAN B64 - RM A401A
1/4" = 1'-0"
9 REFLECTED CEILING PLAN B64 - A443 & A444B
1/4" = 1'-0"
11 REFLECTED CEILING PLAN B64 - RMS CB4 & CB5
1/4" = 1'-0"
5 REFLECTED CEILING PLAN B64 - C138J & C138L
1/4" = 1'-0"
8 REFLECTED CEILING PLAN B64 - RM C144
1/4" = 1'-0"
4 REFLECTED CEILING PLAN B82 - RM 256
1/4" = 1'-0"
7 REFLECTED CEILING PLAN B82 - RM 366
1/4" = 1'-0"
10 REFLECTED CEILING PLAN B82 - RM 481
1/4" = 1'-0"
1 REFLECTED CEILING PLAN B82 - RM168
CEILING LEGEND
GWB ATTACHED
TO HM STUD
REFLECTED CEILING PLAN NOTES:
1. ALL CEILINGS TO BE 8'-0" AFF UNLESS NOTED OTHERWISE.
2. REFER TO SHEET GI002 FOR ALL ABBREVIATIONS
3. CONTRACTOR TO VERIFY LOCATIONS OF MAIN CEILING TEES BEFORE
PROCEEDING WITH FIXTURE INSTALLATION. NOTIFY ARCHITECT OF
INTERFERENCES.
4. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL
REFLECTED CEILING PLANS AND ELECTRICAL LIGHTING PLANS PRIOR TO
CONSTRUCTION.
5. REFER TO ELECTRICAL PLANS FOR LOCATIONS OF STROBES AND EXIT SIGNS.
6. ALL CEILING GRILLES, TRIM EDGES AND SLOT DIFFUSERS TO MATCH ADJACENT
CEILING COLOR.
7. ALL SPRINKLER HEADS TO OCCUR AT CENTER OF TILES.
8. LAYOUT TILES AS SHOWN IN REFLECTED CEILING PLANS.
9. REFER TO SPECIFICATIONS FOR ALL ACOUSTICAL PANEL CEILING TYPES.
10. SEE AS501 SHEETS FOR ROOM FINISH SCHEDULE FOR CEILING FINISH
INFORMATION.
11. WHERE NO CEILING MATERIAL IS SHOWN THE STRUCTURE ABOVE IS TO BE
EXPOSED, U.N.O.
12. SEE EL SHEETS FOR CONTINUED LIGHTING INFORMATION
13. SEE MH SHEETS FOR CONTINUED MECHANICAL INFORMATION.
ELECTRICAL SYMBOLS INDICATING LIGHTING LOCATIONS.
REFER TO EL SHEETS FOR SIZE/ TYPE OF LIGHTING FIXTURE
MECHANICAL SYMBOLS INDICATING SUPPLY DIFFUSER OR
EXHAUST/ RETURN GRILLE LOCATIONS. REFER TO MH
SHEETS FOR SIZE/ TYPE OF DIFFUSER/ GRILLE.
ACOUSTICAL TILE CEILING
2'-0" x 2'-0" ON METAL
SUSPENSION GRID
NO HATCH SHOWN
INDICATES EXISTING CEILING
TO REMAIN, UNLESS NOTED
OTHERWISE
SPRINKLER HEAD LOCATIONS - SEE FP DRAWINGS FOR
ADDITIONAL INFORMATIN
ROOM OCCUPANCY SENSOR - SEE ELECTRICAL
DRAWINGS FOR ADDITIONAL INFORMATION
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED
NEW PARTITION (SEE PARTITION
TYPES FOR ADDITIONAL INFO.)
TEMPORARY PARTITION
NOTES:
TEMPORARY WALL SHALL RESIST PASSAGE OF SMOKE PER NFPA 241. 1HR PARTITION
REQUIRED IF FIRE SUPPRESSION SYSTEM IS DISABLED. LOCATION OF TEMPORARY
PARTITIONS IS GENERAL IN NATURE. GC TO LOCATE ALL TEMPORARY PARTITIONS
AND DOORS AS REQUIRED TO PROTECT AREA UNDER CONSTRUCTION.
PARTITION LEGEND:
8' - 0"ACP-1
MEN
B64-C136
WOMEN
B64-C135
UNISEX
B64-C132
8' - 6"ACP-1
8' - 6"ACP-1
BLOOD SPEC.
B64-2-C131
C1
WOMEN
B64-A127
MEN
B64-A130
LACTATION
B64-A129
8' - 0"ACP-1
8' - 0"ACP-1
8' - 0"ACP-1
MEN'S
RESTROOM
B19-113
7' - 10"ACP-1
MEN
B64-B204
8' - 6"ACP-1
MEN'S
RESTROOM
B64-A137
8' - 0"ACP-1
VA FORM 08 - 6231
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
Project TitleDrawing Title
Approved:
Phase
Location
Issue Date
Project Number
Building Number
Drawing Number
Checked Drawn
TRUE NORTH WBRC
A R C H I T E C T S • E N G I N E E R S
WWW.WBRCAE.COM
BANGOR, MAINE 207-947-4511
PORTLAND, MAINE 207-828-4511
SARASOTA, FLORIDA 941-556-0757
www.abovegroupinc.com COA/CA Lic. No. 31120
305 East Dr., Suite H, Melbounre, Florida 32904
PH: 321.345.9026
/3 /2 :5 :4 A M
U A u to d e s k A u to s a ve s \R e v it \4 V A L A K E C
IT
Y R E N O V A T
IO
N S A R C H a d a m .c o m s to c k w b rc a e .c o m .r vt
AE112
573A4-18-606RENOVATE COMMON
AREA RESTROOMS
DWW AMC07/09/2021
100% CONSTRUCTION
DOCUMENTS
ENLARGED RESTROOM
REFLECTED CEILING PLANS
FULLY SPRINKLERED
C1 PROVIDE SOFFIT TO MATCH EXISTING WALL THICKNESS @ 7'-0" A.F.F.
KEYNOTES:
1/4" = 1'-0"
3 REFLECTED CEILING PLAN B64 - RM C136
1/4" = 1'-0"
2 REFLECTED CEILING PLAN B64 - RM C132
1/4" = 1'-0"
1 REFLECTED CEILING PLAN B64 - RM A127, A129 & A130
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .