J-2a ENA Appendices 012626.pdf
PDF 3 MB Posted
- Solicitation number
- ENA01
About this file
This document is an Appendix containing existing condition photographs, project location information, and an asbestos survey report for the refurbishment of the ENA (Enid Anna) Facility located at 505 N Willow Street, Kenai, Alaska 99611.
The existing condition photos document five envelopes of work required at the facility. Envelope 01 addresses the roof system, which requires replacement of patched roof materials, flashing, and roof drains, along with testing and replacement of a leaking roof hatch. Envelope 02 identifies rusted guard rails requiring rust treatment and repainting with marine-grade paint, as well as catwalk structure rust treatment and repainting of base and railing with marine-grade paint. Envelope 03 documents peeling paint and rusted panels on exterior surfaces requiring treatment and marine-grade paint application, and rusted panels at the building entrance requiring removal and replacement with design-match siding and insulation. Envelope 04 includes an emergency ladder requiring repainting or replacement if needed, and the ENA Air Traffic Control Tower (ATCT) requiring marine-grade sealant and paint application with color matching to existing materials where possible. Envelope 05 addresses tower cap joints and roof leaks penetrating building interiors.
The asbestos bulk sample analysis report, dated August 24, 2016, was conducted by WEC White Environmental Consultants on samples collected August 23, 2016 from the ENA Tower roof. Testing identified asbestos-containing materials in two of four samples analyzed: Sample ENA-0816-A02 from the southeast edge of the ATCT roof contained 10% chrysotile asbestos in tar mastic material (layer 1 of 2), and Sample ENA-0816-A02B from the same location contained 5% chrysotile asbestos in silver seal material (layer 2 of 2).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 697DCK-26-R-00120 - FE.pdf | ||
| J-1 Statement Of Work ENA Envelope 012626.pdf | ||
| J-2 20011949 ENA Spec 012626.pdf | ||
| J-3 Wage Determination.pdf | ||
| J-2b Drawings.pdf | ||
| J-4 Price Proposal Spreadsheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX A
EXISTING CONDITION PHOTOS
REFURBISH ENA FACILITY ENVELOPE 01 of 05
Patched roof system, flashing and roof drains to be replaced.
Roof hatch leaking, to be tested by contractor and replace it if needed.
REFURBISH ENA FACILITY ENVELOPE 02 of 05
Rusted guard rails, repaint with marine grade paint after rust treatment.
Catwalk structure, rust treatment and repaint base and railing with marine grade paint.
REFURBISH ENA FACILITY ENVELOPE 03 of 05
Peeling paint and/or rusted panels, treat it and apply marine grade paint for exteriors surfaces.
Building entrance showing rusted panels which seems to be throughout the siding, remove and replace with design match siding and insulation.
REFURBISH ENA FACILITY ENVELOPE 04 of 05
Emergency ladder rusted and required repaint or replacement if needed.
ENA ATCT, using marine grade sealant and paint, match existing color if possible.
REFURBISH ENA FACILITY ENVELOPE 05 of 05
Tower cap joints / roof leaking into building interiors.
APPENDIX B
PROJECT LOCATION
-ii- u
-z.'&
=- I l
·u 505 N Willow St, Kenai, AK 99611
Razak A Albarqaawee Callout Access Road
APPENDIX C
ASBESTOS SURVEY REPORT
| APPENDIX A |
| A-ENA ATCT Photos |
| 5.0 Pictures |
| APPENDIX B |
| B- ENA ATCT Location |
| APPENDIX C |
| C- SUPPLEMENTARY INSTRUCTIONS TO BIDDERS |
| APPENDIX D |
| D- ENA ATCT Roof ACM PLM 2016-08-23 |
File details come from the government source that posted it. Updated .