This file is a bidders questions and responses document (ITB 1211) for the State of Idaho's procurement of a Combination Sewer Cleaner Truck. The document addresses 40 clarification questions submitted by prospective vendors regarding technical specifications outlined in sections 1.3.1 through 21.5.8 of the invitation to bid. Key specifications covered include equipment components such as debris tank features, dump height requirements, vacuum systems, water pumps, pressure gauges, hose reels, control panels, emergency stop mechanisms, pipe storage configurations, and toolbox dimensions and locations. The Idaho Transportation Department (ITD) responded to each question with acceptance or rejection of proposed alternatives, providing bidders with critical guidance on specification compliance and acceptable substitutions prior to bid submission.
The responses demonstrate ITD's flexibility on certain specifications while maintaining firm requirements on others. Notable acceptances include extending delivery timelines from 180 days to 365 days, accepting manual gauges and level indicators as alternatives to digital systems, reducing dump height from 60 inches to 50 inches, accepting dump bodies without ejectors, allowing single separators, accepting 4000 CFM vacuum systems instead of 4500 CFM, permitting tri-plex pumps as alternatives to single piston pumps, and accepting factory-standard storage configurations and toolbox dimensions. However, ITD maintained non-negotiable requirements including mandatory electronic overfill alarms, insulated water lines (rejecting rubber jacketed steel braided lines), remote emergency stops on all four sides of the truck, and a required drain valve from the lowest point of the debris tank. No pricing information, set-asides, incumbent information, or funding details are provided in this document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ITB 1211 Amendment 1 Administrative Document.docx | DOCX document | |
| State of Idaho Contract Terms and Conditions ITB 1211.docx | DOCX document | |
| Insurance Requirements ITB 1211.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
No ITB Section ITB Page Question Response
| 1 | 1.3.1 | 10 | Clarify if you must have an Idaho Worker's Compensation if you have no employee working or living in the State o Idaho? | No |
| 2 | 5.1 | 11 | Will delivery timeline of greater than 180 days be accepted? | ITD will accept 365 day delivery |
| 3 | 5.1 | 11 | Requested time delivery is currently delivery within 180 date from date of order. With Supply and demand issues during Covid, this drove up the build times to 24 months. We are currently getting back on track and these have been closer to 12 months. Would you consider changing the dilivery time frame to 12 months? | ITD will accept 365 day delivery |
| 4 | 13 | “Is this bid requesting a Wastewater Recycling System? | No. | |
| 5 | 9.1 | 14 | Is the digital level indicator mandatory? Our product uses a manual guage | ITD will accept a manual guage. |
| 6 | 9.1 | 14 | Will a Level Indicator on the outside of the debris tank work as an equal to the digital indicator? It is a more reliable Option. | ITD will accept a level indicator. |
| 7 | 9.2 | 14 | Is a minimum 60” dump height required? Our product performs a 50" dump height | ITD will accept a 50 inch dump height. |
| 8 | 9.2 | 14 | Is a high-pressure water system acceptable as an ejector? | ITD will accept a dump body without an ejector. |
| 9 | 9.2 | 14 | Spec calls for dump system to have min 60” dump height and be equipped with an ejector. Will ITD accept a dumping dump body with 60” dump height and not include an ejector? | ITD will accept a dump body without an ejector. |
| 10 | 9.2 | 14 | The spec calls for an ejector. Is a debris body washout nozzle considered an ejector? If not, can you please define? | ITD will accept a dump body without an ejector. |
| 11 | 9.2 | 14 | Will a debris tank that dumps work as an equal to an ejector plate as a means to dumping the load? | ITD will accept a dump body without an ejector. |
| 12 | 9.3 | 14 | Is a 5 o’clock position acceptable in lieu of a 3 o’clock? | ITD will accept either, 3 o'clock or 5 o'clock |
| 13 | 9.4 | 14 | Is a full-size bottom drain valve required? Our product offers a dumping body for safety and cleanliness. | ITD requires a drain valve from bottom lowest point. |
| 14 | 9.4 | 14 | Spec calls for debris tank to have a full-size bottom drain valve. Will a 6” port located at the bottom of the rear door be accepted? | ITD will accept bottom rear door mounted drain valve. |
| 15 | 9.5 | 14 | This section calls out for “separators”, due to efficiencies of the design is a single separator acceptable? | ITD will accept a single separator. |
| 16 | 10.1 | 14 | Is a 4000 vacuum system acceptable in lieu of 4500? | ITD will accept 4000 CFM. |
| 17 | 11.1 | 14 | Is an Electronic Overfill mandatory or is a manual overfill acceptable? | Electronic overfill alarm is required. |
| 18 | 11.1 | 14 | Will a water tank made out of a ½” welded poly tank material with a ten year warranty by acceptable in place of Aluminum Tanks? | ITD will accept a corrosion proof tank. |
| 19 | 11.2 | 14 | Is a tri-plex pump acceptable in lieu of a since piston pump? | ITD will accept tri-plex pump. |
| 20 | 11.2 | 14 | Will a Triplex Water pump with run dry capabilities with a 80 Gallons Per Minute Capability work as an equal to the Single Piston Water Pump? | ITD will accept tri-plex pump. |
| 21 | 11.3 | 14 | Can the pressure gauge be located at the control panel on the vehicle in lieu of at the front at ground level? | Pressure guage and control panel is required at the front at ground level. As stated in Section 15.1. |
| 22 | 13.2 | 14 | Due to reliability we do not hydraulically extend or retract, our real does not extend or retract, since we have a direct drive real is this specification mandatory? | ITD will accept a direct drive reel. |
| 23 | 13.3 | 14 | The term “installed safety covers”, does this refer to safety covers for the connecting of the Jet hose to hose reel or is the spec wanting a plexiglass cover over the hose reel? | Safety cover/covers must be installed to cover rotating components, pinch points, high pressure connections and hazards around the reel. |
| 24 | 15.2 | 14 | Is the intelligent control panel mandatory? We offer an external control panel located by the reel. | ITD will accept external control panel. |
| 25 | 15.2 | 14 | The In-Cab Dash mounted intelligent electronic control is a brand specific option requirement. Will a truck where the dash mounted intelligent controller is not needed be acceptable? The computerized controllers add a level of complexity and increased maintenance costs. | ITD will accept external control panel. |
| 26 | 15.4 | 15 | Spec calls for remote emergency stops on all four sides of the truck. Will a wireless remote with emergency stop that has an operating range of all sides of the truck be accepted where a physical remote stop is not located? | ITD requires remote emergency stops on all four sides of the truck. |
| 27 | 15.4 | 15 | Is it acceptable to have remote emergency stops on the front of the truck, curbside of the truck and on the remote instead of on all 4 sides of the truck? | ITD requires remote emergency stops on all four sides of the truck. |
| 28 | 17.1 | 15 | Is it acceptable to have storage for a total of 8 tubes in a different configuration than what is in specification? 6 tubes on curbside and 2 tubes on streetside of the truck? | ITD will accept factory standard storage for 8 pipes. |
| 29 | 21.5.5 | 16 | Will a similar amount of tool boxes for a total of 6 be in a different configuration be acceptable? The configuration in the specification is for specific brand of truck with tool boxes that fit there body configuration. | ITD will accept factory standard locations for 6 toolboxes. |
| 30 | 17.1.3 | 15 | Is a subframe mandatory, we can offer one single on the back as an option. | ITD will accept single mount on rear. |
| 31 | 21.5.1 | 16 | Are 18” width, 18” height, 60” long tool boxes acceptable? | ITD will accept. |
| 32 | 21.5.1 | 16 | Will two 30"x18"x18" passenger side toolboxes with retractable two-step ladder be acceptable | ITD will accept. |
| 33 | 21.5.2 | 16 | Are 18” width, 18” height, 60” long tool boxes acceptable? | ITD will accept. |
| 34 | 21.5.2 | 16 | Will two 30"x18"x18" passenger side toolboxes with retractable two-step ladder be acceptable | ITD will accept. |
| 35 | 21.5.3 | 16 | Is this tool storage box mandatory? | ITD requires tool storage box. |
| 36 | 21.5.4 | 16 | Will a 24”x42” x100” tool box mounted behind the cab be acceptable? | ITD will accept. |
| 37 | 21.5.5 | 16 | This is body Specific – Will storage boxes formed into front bumper with aluminum locking side access cover on Drivers and open top storage box for Tube clamps be acceptable? | ITD will accept. |
| 38 | 21.5.8 | 16 | Are heated cabinets mandatory? | ITD will accept non heated cabinets. |
| 39 | 21.5.8 | 16 | Spec calls for insulated lines. Will ITD accept rubber jacketed steel braided water lines as insulated? | ITD requires water lines to be insulated. Rubber jacketed steel braided lines is not insulated and not acceptable. |
| 40 | 21.5.8 | 16 | Spec calls for heated cabinets. With the recirculation of the water as called out, this is to prevent freezing on the rodder hose, washdown hoses, etc. With this feature, is there still a need to heat the cabinets? If yet, please specific which cabinet? | ITD will accept non heated cabinets. |