Issued for Construction Drawing set 565-20-103 Renovate Audiology for Specialty Clinics.pdf

PDF 35 MB Posted

Attached to
Y1DA--Renovate Audiology for Specialty Clinics
Solicitation number
36C24623B0023
Issued by

About this file

This solicitation is for renovating audiology services for specialty clinics within the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 6. Offerors are sought to renovate the audiology area to improve specialty care services. The solicitation number is 36C24623B0023 and responses are due by the date listed on the Federal Business Opportunities website. Renovations should update the audiology facilities and allow for expanded audiology services for veterans. Interested contractors should monitor the website for additional details and response requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

ENVIRONMENTAL:

ECS SOUTHEAST

6714 NETHERLANDS DR.

WILMINGTON, NC 28405

POC: AMY DESAIX

T: 901-319-1000

SMEP:

CANNON DESIGN

1560 WILSON BLVD. STE. 200

ARLINGTON, VA 22209

POC: SCOTT PEGLER

T: 703-907-2384

ARCHITECT:

CB DESIGN GROUP

421 KING ST.

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

COST ESTIMATION:

OCMI

6110 EXECUTIVE BLVD. STE. 200

ROCKVILLE, MD 20852

POC: MIKE VELOSE

T: 704-280-8356

TELECOMMUNICATIONS:

SHEN MILSOM WILKE LLC

1220 N. FILLMORE ST. STE. 360

ARLINGTON, VA 22201

POC: GIDEON MAHN

T: 703-721-8039

# REVISION DATE

0 ISSUED FOR CONSTRUCTION 08/24/22

08/24/2022

565-20-103

COKJ

RENOVATE AUDIOLOGY FOR

SPECIALTY CLINICS

100% BID DOCUMENTS

COVER SHEET

GI100

-2

-1

G I1

.p d f

FAYETTEVILLE VAMC

2300 RAMSEY ST.

FAYETTEVILLE, NC 28301

Department of Veterans Affairs

RENOVATE AUDIOLOGY FOR SPECIALTY CLINICS

2300 RAMSEY STREET

FAYETTEVILLE, NC 28301

BID DOCUMENTS

LOCATION MAP DRAWING LIST PROJECT DIRECTORY

CONTRACTING OFFICER REPRESENTATIVE (COR)

KEVIN PEEL

FAYETTEVILLE VAMC

2300 RAMSEY ST. BLDG. 1-442

PHONE: (910) 551-6816

kevin.peel@va.gov

ARCHITECT

WES BRIDGES

CB DESIGN GROUP, INC

421 KING ST. STE. 301

ALEXANDRIA, VA 22314

PHONE: (888) 585-CBDG (2234)

wbridges@cbdg-ae.com

MEP/FP/STRUCTURAL ENGINEER

SCOTT PEGLER

CANNON DESIGN

1560 WILSON BLVD. STE. 200

ARLINGTON, VA 22209

PHONE: (703) 907-2384

spegler@cannondesign.com

CONTRACTING OFFICER (CO)

WAYNE GOODMOND

NCO-6: RPO EAST

2300 RAMSEY ST. BLDG. 4-006

PHONE: (910) 482-5112

wayne.goodmond@va.gov

FIRE PROTECTION

FP0001 LEGENDS, SYMBOLS & ABBREVIATIONS

D0501 BASEMENT LEVEL FIRE PROTECTION DEMOLITION PLAN

FP0101 BASEMENT LEVEL FIRE PROTECTION PLAN

ELECTRICAL

E0001 NOTES, LEGENDS, SYMBOLS, AND ABBREVIATIONS

ED0801 BASEMENT LEVEL DEMOLITION PLAN

E0101 BASEMENT LEVEL - LIGHTING PLAN

E0201 BASEMENT LEVEL - POWER AND SYSTEMS PLAN

E0521 POWER DEMO AND NEW RISER DIAGRAMS

E0621 POWER SCHEDULES

E0701 LIGHTING CALCULATIONS AND DETAILS

FIRE ALARM

FA0001 BASEMENT FIRE ALARM PLAN AND DETAILS

TELECOMMUNICATIONS

TT000 TELECOM SYMBOLS, ABBREVIATIONS & NOTES

TT100 TELECOM FLOOR PLAN - BASEMENT LEVEL

TT200 TELECOM REFLECTED CEILING PLAN - BASEMENT

LEVEL

TT501 TELECOM DETAILS

TT502 TELECOM DETAILS

QH100 EQUIPMENT PLANS / SCHEDULES

QH201 EQUIPMENT PLANS / SCHEDULES

QH202 EQUIPMENT PLANS / SCHEDULES

QH203 EQUIPMENT PLANS / SCHEDULES

QH204 EQUIPMENT PLANS / SCHEDULES

QH205 EQUIPMENT PLANS / SCHEDULES

QH206 EQUIPMENT PLANS / SCHEDULES

QH207 EQUIPMENT PLANS / SCHEDULES

QH208 EQUIPMENT PLANS / SCHEDULES

QH209 EQUIPMENT PLANS / SCHEDULES

QH210 EQUIPMENT PLANS / SCHEDULES

STRUCTURAL

S0100 GENERAL NOTES AND BASEMENT FRAMING PLAN

MECHANICAL

M0001 SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES

MD0601 BASEMENT LEVEL - HVAC DEMOLITION PLAN

MD0602 CRAWL SPACE - HVAC DEMOLITION PLAN

M0101 BASEMENT LEVEL - HVAC DUCTWORK PLAN

M0102 CRAWL SPACE - HVAC DUCTWORK PLAN

M0201 BASEMENT LEVEL - HVAC PIPING PLAN

M0202 CRAWL SPACE - HVAC PIPING PLAN

M0501 SCHEDULES

M0601 FLOW AND CONTROL DIAGRAMS

M0602 FLOW AND CONTROL DIAGRAMS

M0701 DETAILS

PLUMBING

P0001 LEGENDS, SYMBOLS & ABBREVIATIONS

D0300 CRAWL SPACE PLUMBING DEMOLITION PLAN

D0301 BASEMENT LEVEL PLUMBING DEMOLITION PLAN

P0100 CRAWL SPACE PLUMBING PLAN

P0101 BASEMENT LEVEL PLUMBING PLAN

P0401 CRAWL SPACE DOMESTIC WATER RISER DIAGRAM

P0402 BASEMENT LEVEL DOMESTIC WATER RISER DIAGRAM

P0403 SANITARY RISER DIAGRAM

P0501 SCHEDULES

GENERAL

GI100 COVER SHEET

GI200 SYMBOLS, ABBREVIATIONS & NOTES

GI300 GENERAL NOTES

GI301 TYPICAL MOUNTING HEIGHTS AND DIMENSIONING

CONVENTIONS

GC200 EXISTING CONDITIONS PLAN - BASEMENT LEVEL

GC400 ICRA PLAN

GC500 PSRA MATRIX

LIFE SAFETY

LS-100 LIFE SAFETY PLAN

ARCHITECTURAL

AD100 DEMOLITION PLAN

AS100 ARCHITECTURAL SITE PLAN

AE100 FLOOR PLANS

AE200 ELEVATIONS

AE300 SCHEDULES

AE301 WALL TYPES

AE302 DOOR SEQUENCE & OPERATION

AE400 BUILDING SECTIONS

AE410 WALL SECTIONS & DETAILS

AE500 ENLARGED PLANS

AE501 ENLARGED PLANS

AE510 DETAILS

AE601 INTERIOR ELEVATIONS

AE602 INTERIOR ELEVATIONS

AE603 INTERIOR ELEVATIONS

AE700 REFLECTED CEILING PLANS / DETAILS

AE710 CEILING DETAILS

AE800 SIGNAGE PLAN

AE801 SIGNAGE TYPES

AE900 MILLWORK DETAILS - SINKS

AE901 MILLWORK DETAILS - BREAK ROOM

IF001 FINISH SCHEDULE

IF100 FLOOR FINISH PLAN

EQUIPMENT (HOSPITAL)

PROJECT 565-20-103

NOT TO SCALE

FAYETTEVILLE

VAMC CAMPUS

BUILDING 1

B WING (PROJECT

LOCATION)

WOOD

ALUMINUM

STEEL

EARTH

CONCRETE MASONRY UNITS

RIGID INSULATION

CONCRETE

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE REMOVED

BRICK

WOOD-FINISHED

WOOD ROUGH

PLYWOOD

GYPSUM - PLASTER

ACOUSTIC TILE

CAST STONE

ALL METALS - SMALL SCALE

GLASS - LARGE SCALE

BATT INSULATION

CERAMIC TILE

CARPET

GRAVEL

CENTER LINE

DETAIL INDICATOR

DETAIL INDICATIOR

DIMENSION LINE

DRAWING BLOCK TITLE, TYPICAL

ELEVATION INDICATOR, EXTERIOR

INTERIOR ELEVATION INDICATOR, INTERIOR, MULTIPLE VIEW

ELEVATION INDICATOR, INTERIOR, SINGLE VIEW

SECTION INDICATOR

TYPICAL DETAIL INDICATOR

COLUMN GRID

KEYNOTE

NORTH ARROW

A

DETAIL NUMBER

SHEET WHERE

DRAWN

XXxxx

XXxxx

X

DRAWING TITLE

SCALE: 1 1/2" = 1'-0"

1 1/2"

XXxxx

XXxxx

XXxxx

REVISION

REVISION CLOUD

NORTH

BREAK LINE

DEMOLITION KEYNOTE

A

XXxxx

D

BC

COLUMN NUMBER

COLUMN LETTER

XXxxx

ELEVATION NUMBER

SHEET WHERE

DRAWN

SECTION NUMBER

SHEET WHERE

DRAWN

ELEVATION NUMBER

SHEET WHERE

DRAWN

DETAIL NUMBER

SHEET WHERE DRAWN

DETAIL NUMBER

SHEET WHERE DRAWN

SHEET WHERE

DRAWN

ELEVATION NUMBER

DOOR / BORROWED LIGHT TAG

FURNITURE, FIXTURE, & EQUIPMENT TAG

WALL/PARTITION TAG

x'-x" VERTICAL HEIGHT INDICATOR

ROOM NAME

This is a sample description

150 SF

500 SF

ROOM NAME

150 SF

A3

ROOM NUMBER

ROOM AREA

PROGRAM AREA

D1

& AND

@ AT

C CENTERLINE

# NUMBER

AB ANCHOR BOLT

ABV ABOVE

ACT ACOUSTIC CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH

DISABILITIES ACT

ADJ ADJUSTABLE

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF

ARCHITECTS

ALUM ALUMINUM

ALT ALTERNATE

AP ACCESS PANEL

APPROX APPROXIMATE

ARCH ARCHITECTURAL

AUTO AUTOMATIC

AVG AVERAGE

BD BOARD

BLDG BUILDING

BLK BLOCK

BM BEAM

BOT BOTTOM

BRG BEARING

BEL BELOW

BR BUMPER RAIL

BRWD BULLET RESISTANT WOOD

BRK BRICK

CAB CABINET

CB CATCH BASIN

CEM CEMENT

CCT CUBICLE CURTAIN TRACK

CG CORNER GUARD

CI CAST IRON

CIP CAST IN PLACE

CJ CONTROL JOINT

CT CERAMIC TILE

CLG CEILING

CL CLOSET

COL COLUMN

CONC CONCRETE

CONF CONFERENCE

CONT CONTINUOUS

CPT CARPET

CR CARD READER

CT CERAMIC TILE

CU CUBIC

DBL DOUBLE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DISP DISPENSER

DN DOWN

DO DOOR OPENING

DOZ DOZEN

DP DAMPPROOFING

DR DOOR

DWG DRAWING

DWGS DRAWINGS

DWR DRAWER

E EAST

EA EXHAUST AIR, EACH

EL ELEVATION

ELEV ELEVATION

ELEC ELECTRICAL

EMER EMERGENCY

ENCL ENCLOSURE

ENGR ENGINEER

EP ELECTRICAL PANELBOARD

EQ EQUAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWS EYE WASH STATION

EXP EXPANSION

EJ EXPANSION JOINT

EXIST EXISTING

EXT EXTERIOR

FA FIRE ALARM

FB FACE BRICK

FD FLOOR DRAIN

FDC FIRE DEPARTMENT

CONNECTION

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER

CABINET

FF FINISH FACE

FHC FIRE HOSE CABINET

FIN FINISH

FLR FLOOR

FLUOR FLUORESCENT

FO __ FACE OF __

FOC FACE OF CONCRETE

FOS FACE OF STUD

FOW FACE OF WALL

FPRF FIREPROOF(ING)

FR FIRE RATING, FRAME

FRMG FRAMING

FS FULL SIZE

FT FOOT OR FEET

FTG FOOTING

FUR FURRING

FUT FUTURE

GC GENERAL CONTRACTOR

GA GAUGE

GAL GALLON

GALV GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR

GD GUARD

GL GLASS

GND GROUND

GR GRADE

GWB GYPSUM WALLBOARD

GYP BD GYPSUM WALLBOARD

HB HOSE BIBB

HC HOLLOW CORE

HD HEAD

HDWR HARDWARE

HDWD HARDWOOD

HT HEIGHT

HNDRL HANDRAIL

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMF HOLLOW METAL FRAME

HR HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HP HIGH POINT

HR HOUR

HVAC HEATING, VENTILATION, AIR

CONDITIONING

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE

DIAMETER / DIMENSION

IN INCH

INCL INDLUDE(D)

INSUL INSULATION

INT INTERIOR

INV INVERT

JAN JANITOR

JST JOIST

JT JOINT

KP KICK PLATE

KO KNOCKOUT

L LENGTH

LAB LABORATORY

LAM LAMINATE

LAV LAVATORY

LBS POUND

LED LIGHT EMITTING DIODE

LF LINEAR FEET

LH LEFT HAND

LIN LINEAR

LIQ LIQUID

LKR LOCKER

LG LONG

LL LEAD LINED

LLV LONG LEG VERTICAL

LP LOW POINT

LRG LARGE

LT LIGHT

LT WT LIGHTWEIGHT

LVR LOUVER

MATL MATERIAL

MAS MASONRY

MAX MAXIMUM

MECH MECHANICAL

MTL METAL

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MP MOP PLATE

MTD MOUNTED

N NORTH

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER / DIMENSION

OFF OFFICE

OH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OH OVERHEAD

OZ OUNCE

PAV PAVING

PC PRECAST CONCRETE

PL PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLYWD PLYWOOD

PLBG PLUMBING

PMF PREMOLDED FILLER

PR PAIR

PT POINT

PTN PARTITION

QT QUARRY TILE

R RADIUS, RISER

RA RETURN AIR

RAD RADIUS

RB RESILIENT BASE, RUBBER

BASE

RD ROOF DRAIN

RL ROOF LEADER

REF REFERENCE

REFR REFRIGERATOR

REQ'D REQUIRED

REV REVISION

RFI REQUEST FOR

INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RM ROOM

RO ROUGH OPENING

S SOUTH

SA SUPPLY AIR

SAN SANITARY

SC SOLID CORE

SCWD SOLID CORE WOOD

SCHED SCHEDULE

SECT SECTION

SH SPRINKLER HEAD

SHT SHEET

SIM SIMILAR

SM SMOKE

SPEC SPECIFICATION

SPKR SPEAKER

SQ SQUARE

STA STATION

STD STANDARD

STO STORAGE

STL STEEL

SS STAINLESS STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

SYM SYMMETRICAL

SYS SYSTEM

T TREAD

TEL TELEPHONE

TEMP TEMPERED

T&G TONGUE AND GROOVE

THK THICK

TOC TOP OF CONCRETE

TOP TOP OF PAVEMENT

TOS TOP OF STEEL

TOW TOP OF WALL

TV TELEVISION

TYP TYPICAL

UNFIN UNFINISHED

UON UNLESS OTHERWISE

NOTED

VB BAPOR BARRIER

VERT VERTICAL

VCT VINYL COMPOSITION TILE

VIF VERIFY IN FIELD

VTR VET THRU ROOF

W WEST

W/ WITH

WD WOOD

W/O WITHOUT

WP WATERPROOF

WT WEIGHT

WWF WELDED WIRE FRAME

NOTE: ALL ABBREVIATIONS SHOWN

MAY NOT BE USED ON THIS PROJECT.

CERTAIN COMMON ABBREVIATIONS

MAY NOT BE SHOWN.

L

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

ENVIRONMENTAL:

ECS SOUTHEAST

6714 NETHERLANDS DR.

WILMINGTON, NC 28405

POC: AMY DESAIX

T: 901-319-1000

SMEP:

CANNON DESIGN

1560 WILSON BLVD. STE. 200

ARLINGTON, VA 22209

POC: SCOTT PEGLER

T: 703-907-2384

ARCHITECT:

CB DESIGN GROUP

421 KING ST.

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

COST ESTIMATION:

OCMI

6110 EXECUTIVE BLVD. STE. 200

ROCKVILLE, MD 20852

POC: MIKE VELOSE

T: 704-280-8356

TELECOMMUNICATIONS:

SHEN MILSOM WILKE LLC

1220 N. FILLMORE ST. STE. 360

ARLINGTON, VA 22201

POC: GIDEON MAHN

T: 703-721-8039

# REVISION DATE

0 ISSUED FOR CONSTRUCTION 08/24/22

08/24/2022

565-20-103

COKJ

RENOVATE AUDIOLOGY FOR

SPECIALTY CLINICS

100% BID DOCUMENTS

SYMBOLS, ABBREVIATIONS & NOTES

GI200

-2

-1

G I2

.p d f

FAYETTEVILLE VAMC

2300 RAMSEY ST.

FAYETTEVILLE, NC 28301

SYMBOLS OF MATERIALS DRAWING KEY ARCHITECTURAL ABBREVIATIONS

1. HOSPITAL STAFF SHALL ENSURE THE REMOVAL OF ANY MEDICAL WASTE, INCLUDING SHARPS CONTAINERS, FROM AREAS TO

BE RENOVATED, PRIOR TO THE START OF THE PROJECT.

2. INFECTION CONTROL SHALL BE NOTIFIED BY FACILITIES MANAGEMENT STAFF IMMEDIATELY IF UNEXPECTED MEDICAL WASTE

IS ENCOUNTERED.

IN STRIVING TO PROVIDE A HEALTHY AND SAFE ENVIRONMENT AT VA FACILITIES, VHA HAS A SMOKE-FREE POLICY FOR ALL VHA HEALTH CARE FACILITIES AND PROPERTY ASSIGNED TO VHA THAT IS UNDER THE CHARGE AND CONTROL OF VA. THE POLICY APPLIES TO CIGARETTES, CIGARS, PIPES OR ANY OTHER COMBUSTION OF TOBACCO, INCLUDING BUT NOT LIMITED TO ELECTRONIC

OR E-CIGARETTES, VAPE PENS OR E-CIGARS.

UNDER VHA DIRECTIVE 1085, ALL VHA HEALTH CARE FACILITIES ARE SMOKE-FREE FOR PATIENTS, VISITORS, CONTRACTORS, VOLUNTEERS AND VENDORS EFFECTIVE OCTOBER 1, 2019.

1. VA DESIGN MANUAL (PG-18-0)

2. VA DESIGN, QUALITY, AND STANDARD ALERTS

3. VA DESIGN GUIDES (PG-18-12)

4. VA DESIGN AND CONSTRUCTION

PROCEDURES (PG-18-3)

5. PHYSICAL SECURITY DESIGN MANUAL FOR VA

FACILITIES

6. VA FIRE PROTECTION DESIGN MANUAL

7. VA BARRIER FREE DESIGN GUIDE (PG-18-3)

8. VA SIGNAGE DESIGN GUIDE

9. VA MASTER SPECIFICATIONS

10. VA SUSTAINABLE DESIGN MANUAL

REFER TO "ASBESTOS AND LEAD PAINT SURVEY" IN APPENDIX OF PROJECT NARRATIVE AND ASBESTOS AND LEAD ABATEMENT

SPECIFICATION SECTIONS.

G1 ITEMS AND CONDITIONS NOTED, DETAILED, OR OTHERWISE IDENTIFIED ON DRAWINGS ARE APPLICABLE AND BINDING TO SIMILAR CONDITIONS ON ALL DRAWINGS. FOR CONDITIONS NOT NOTED OR NOT DETAILED, PROVIDE MATERIALS OF EQUAL QUALITY AND PERFORMANCE TO OTHER SIMILAR CONDITIONS ON

THE JOB.

G2 SECTIONS SHOWN ARE INTENDED TO SHOW THE SPECIFIC CONSTRUCTION WHERE INDEXED AS WELL AS ESTABLISH THE GENERAL CONSTRUCTION DETAILS FOR SECTIONS THROUGHOUT THE PROJECT WHICH DO NOT HAVE SPECIFIC SECTIONS DRAWN. THE MOST SIMILAR SECTION SHALL BE ADAPTED TO ANY SECTION NOT DETAILED. ANY SPECIFIC QUESTIONS CONCERNING CONSTRUCTION NOT ADEQUATELY COVERED BY THE ABOVE SHOULD BE DIRECTED TO THE ARCHITECT.

G3 ALL CONSTRUCTION IS TO BE ASSUMED NEW AND FURNISHED AND INSTALLED BY THE CONTRACTOR, UNLESS NOTED OTHERWISE.

G4 REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR NOTES PERTAINING TO THEIR PARTICULAR TRADES. COORDINATE THE WORK OF ALL TRADES AND REPORT TO THE ARCHITECT ANY PERCEIVED DISCREPANCIES. CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING SEQUENCES OF CONSTRUCTION AND MEANS AND METHODS FOR HOW TO PERFORM THE WORK REQUIRED IN THE CONTRACT DOCUMENTS. ALL CONTRACTORS SHALL CAREFULLY REVIEW ALL EXISTING CONDITIONS AND DETERMINE THE MOST FEASIBLE SEQUENCE FOR PERFORMING THE NEW WORK SO AS TO AVOID CONFLICTS IN THE FIELD.

G5 ANY AREAS OR SPACES NOT CLEARLY DEFINED OR INDICATED BY NOTES SHALL BE OF SAME MATERIAL AND FINISH AS AREAS OF SIMILAR USE OR FUNCTION

ELSEWHERE IN THE BUILDING.

G6 WALL AND CEILING FINISHES SHALL INCLUDE PROJECTIONS, BEAM ENCLOSURES, RECESSES, BULKHEADS, PILASTERS AND OTHER SIMILAR ITEMS.

G7 ALL APPURTENANCES BUILT INTO OR THROUGH WALLS, INCLUDING DOORS, WINDOWS, DUCTS, FRAMES, LOUVERS, GRILLES, MECHANICAL WORK, ETC., SHALL FIT SNUGLY AND BE THOROUGHLY SEALED AROUND PERIMETERS. INSTALL FIRE SEALANT AROUND ALL PENETRATIONS THROUGH FLOORS, FIRE RATED WALLS AND SMOKE PARTITIONS. WORK AT EXTERIOR WALLS SHALL BE FLASHED OR OTHERWISE WATERPROOF SEALED.

G8 FIELD CHECK ROUGH AND/OR FINISHED DIMENSIONS FOR ACCURATE FITTING OF CABINETS, COUNTERS, STOREFRONT, DOORS, FRAMES, FIXTURES, MILLWORK AND ALL OTHER INSTALLATIONS PRIOR TO SHOP OR FACTORY FABRICATION. PROVIDE AND INSTALL NECESSARY FILLER STRIPS, SCRIBE STRIPS, BASES, CLOSURES, FINISHES AND TRIM TO COMPLETE SUCH INSTALLATIONS. DIMENSIONS OF SUCH INSTALLATIONS SHALL BE CONSIDERED "NOMINAL".

CONTRACTORS SHALL ACCOUNT FOR ALL MANUFACTURER'S REQUIRED TOLERANCES, CLEARANCES AND SHIM SPACE TO ENSURE PROPER INSTALLATION OF THE

NEW WORK.

G9 SEE EQUIPMENT PLANS AND FLOOR PLANS FOR CASEWORK, CABINETS, MILLWORK AND OTHER BUILT-IN ITEMS. COORDINATE WITH MEP DRAWINGS FOR

SINKS, OUTLETS, AND OTHER ITEMS TO BE BUILT INTO SUCH ITEMS.

G10 IF A DISCREPANCY APPEARS TO EXIST BETWEEN DRAWINGS OF DIFFERENT SCALES, CONSULT ARCHITECT FOR CLARIFICATION.

G11 IF A DISCREPANCY APPEARS TO EXIST BETWEEN DRAWINGS AND/OR SPECIFICATIONS, THE MORE STRINGENT (TYPICALLY THE MORE COSTLY) REQUIREMENT SHALL APPLY. ITEMS DESCRIBED ON DRAWINGS, BUT NOT SPECIFIED, SHALL BE PROVIDED. CONTRACTOR SHALL BE RESPONSIBLE TO SUBMIT AN

RFI TO SEEK CLARIFICATION OF ANY PERCEIVED DISCREPANCY.

G12 WRITTEN INFORMATION ON DRAWINGS TAKES PRECEDENT OVER DRAWING LINES.

G13 IN THE ABSENCE OF A WRITTEN DIMENSION, OR IN CASE OF DOUBT AS TO THE PROPER MEASUREMENT, CONSULT ARCHITECT. DO NOT SCALE DRAWINGS.

ASSUMPTIONS MADE, OR ACTIONS TAKEN, BASED ON SCALED DIMENSIONS SHALL BE AT THE CONTRACTOR'S RISK AND ANY RESULTING CORRECTIONS SHALL BE

PERFORMED BY CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.

G14 EACH CONTRACTOR OR SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE WORK OF OTHER TRADES SHOWN THROUGHOUT THE COMPLETE SET OF CONTRACT DOCUMENTS. CHANGES RESULTING FROM A CONTRACTOR OR SUB-CONTRACTOR'S FAILURE TO OBTAIN AND REVIEW A COMPLETE SET OF CONTRACT DOCUMENTS SHALL BE CORRECTED AT NO ADDITIONAL COST TO THE GOVERNMENT.

G15 AT ALL CHANGES IN FLOOR FINISHES, PROVIDE AND INSTALL AN APPROPRIATE TRANSITION STRIP AS SHOWN ON THE DRAWINGS.

G16 CONSULT HVAC AND ELECTRICAL DRAWINGS FOR LOCATIONS AND DESCRIPTIONS OF ACCESS PANELS, LOUVER OPENINGS, VENTILATORS, GRILLES, VALVE CABINETS, FIRE DAMPERS OR OTHER APPURTENANCES AFFECTING WALLS, CEILINGS OR FLOORS AND PROVIDE NECESSARY LINTELS, SUPPORT OR ANCHORING.

G17 ELECTRIC SWITCHES, OUTLETS, THERMOSTATS, CONTROLS, CLOCKS, SPEAKERS, OR OTHER WALL-MOUNTED ACCESSORIES SHALL BE INSTALLED IN LOCATIONS WHICH ARE UNOBSTRUCTED BY CABINETS, COUNTERS, RACKS, MARKER AND TACKBOARDS, FIXTURES, SHELVING OR OTHER FURNISHING OR EQUIPMENT DESIGNATED FOR SPACES SHOWN ON DRAWINGS. ITEMS FOR WALL-MOUNTING ARE NOT TO BE INSTALLED ON, THROUGH, OR INTO, ANY EQUIPMENT

OTHER THAN WALLS, UNLESS SPECIFICALLY NOTED OTHERWISE.

G18 ELECTRICAL OUTLETS, CLOCKS, P.A. SPEAKERS, PULL STATIONS, EXIT SIGNS, OR OTHER DEVICES SHOWN DIAGRAMMATICALLY ON THE ARCHITECTURAL DRAWINGS SERVE TO ALERT CONTRACTORS OF THE PRESENCE OF SUCH DEVICES. CONSULT THE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION AND ADVISE ARCHITECT OF ANY PERCEIVED DISCREPANCY BETWEEN ARCHITECTURAL AND ELECTRICAL DRAWINGS REGARDING LOCATION OR TYPE OF DEVICES

SHOWN PRIOR TO PREPARING SUBMITTALS.

G19 ELECTRIC SWITCHES, THERMOSTATS OR OTHER ELECTRONIC CONTROLS IN THE SAME VICINITY SHALL BE MOUNTED AT THE SAME HEIGHT FROM FLOOR

(UNLESS NOTED OTHERWISE) IN A UNIFORM, ORDERLY FASHION.

G20 SUBMITTAL REVIEW - THE CONTRACT DOCUMENTS PROVIDE SIZES, DIMENSIONS, PRODUCT REQUIREMENTS, ETC. CONTRACTOR SHALL VERIFY THAT SUBMITTALS ARE COORDINATED WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS PRIOR TO SUBMISSION. A/E REVIEW OF SUBMITTALS IS NOT FOR THE PURPOSE OF DETERMINING THAT SIZES, DIMENSIONS, ETC MATCH WHAT HAS ALREADY BEEN PROVIDED IN THE CONTRACT DOCUMENTS. ALL DEVIATIONS FROM WHAT IS SHOWN ON THE CONTRACT DOCUMENTS SHALL BE CLOUDED ON THE SUBMITTAL OR OTHERWISE CLEARLY BROUGHT TO THE ATTENTION OF THE REVIEWER. FAILURE TO CLEARLY BRING ANY DEVIATION(S) TO THE ATTENTION OF THE REVIEWER SHALL BE UNDERSTOOD BY ALL PARTIES THAT WHAT IS SHOWN IN THE SUBMITTAL COMPLIES WITH THE CONTRACT DOCUMENTS REGARDLESS OF WHETHER OR NOT THE REVIEWER DISCOVERS THE DEVIATION.

CHANGES RESULTING FROM THE CONTRACTOR'S FAILURE TO CLEARLY IDENTIFY DEVIATIONS IN SUBMITTALS SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY AND SHALL BE CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.

G21 CONTRACTORS SHALL CAREFULLY REVIEW EXISTING FIELD CONDITIONS AND COORDINATE ALL QUANTITIES, DIMENSIONS, AND TOLERANCES REQUIRED TO PERFORM THE WORK SHOWN ON THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR DETERMINING INFORMATION THAT PERTAINS SOLELY TO FABRICATION PROCESSES, INSTALLATION TECHNIQUES (MEANS AND METHODS), AND SEQUENCING OF THE WORK TO MEET THE REQUIREMENTS OF THE PROJECT SCHEDULE. EACH SUBCONTRACTOR SHALL COORDINATE WITH OTHER TRADES PRIOR TO BEGINNING THEIR PORTION OF THE WORK.

G22 PUBLIC EXITS SHALL REMAIN CLEAR AT ALL TIMES WHILE THE BUILDING IS OCCUPIED. NO STORAGE SHALL BE PERMITTED IN THE EXIT ACCESS.

G23 PATCH ALL HOLES IN FLOORS, WALLS AND CEILINGS WITHIN THE PROJECT LIMITS AFTER DEMOLITION AND NEW WORK IS COMPLETE.

G24 UNLESS SPECIFIC DIMENSIONS ARE PROVIDED, MEP DRAWINGS ARE CONSIDERED "DIAGRAMMATIC". IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR(S) TO FIELD COORDINATE LOCATIONS, SEQUENCES, ETC FOR UNOBSTRUCTED INSTALLATION OF ITEMS THAT ARE SHOWN ON MEP DRAWINGS IN DIAGRAMMATIC FORM. COORDINATE ABOVE-CEILING WORK OF MEP TRADES TO THAT EACH TRADE LOCATES THEIR WORK AS TIGHT TO THE STRUCTURE / DECK ABOVE AS IS FEASIBLE. EACH SUCCESSIVE TRADE SHALL LOCATE THEIR WORK AS TIGHT TO THE TRADE BEFORE.

G25 THE DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND NEITHER SHALL TAKE PRECEDENT OVER THE OTHER. WHAT IS REQUIRED BY EITHER THE DRAWINGS OR SPECIFICATIONS SHALL BE INTERPRETED AS BEING REQUIRED AS PART OF THE SCOPE OF WORK FOR THIS PROJECT. ITEMS SPECIFIED, BUT NOT INDICATED ON THE DRAWINGS, SHALL BE PROVIDED. ITEMS SHOWN ON THE DRAWINGS, BUT NOT SPECIFIED, SHALL BE PROVIDED. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO SEEK CLARIFICATION IF THERE SHOULD APPEAR TO BE A DISCREPANCY BETWEEN DRAWINGS AND/OR THE SPECIFICATIONS. OTHERWISE, THE MOST STRINGENT (TYPICALLY THE MOST EXPENSIVE) REQUIREMENT SHALL APPLY AT THE DISCRETION OF THE COR.

G26 ABOVE-CEILING COORDINATION – PRIOR TO PERFORMING ANY ABOVE-CEILING WORK, CONTRACTOR, WORKING WITH ALL SUB-CONTRACTORS, SHALL CREATE DRAWINGS THAT SHOW COORDINATION OF ALL ABOVE-CEILING WORK ITEMS WITH EXISTING CONDITIONS AND PROPOSED CEILINGS. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE SEQUENCES OF INSTALLATION TO ENSURE THAT ABOVE-CEILING ITEMS CAN FIT ABOVE THE CEILING HEIGHTS INDICATED ON THE REFLECTED CEILING PLAN(S). CONTRACTOR SHALL BRING ALL PERCEIVED CONFLICTS TO THE ATTENTION OF THE ARCHITECT / ENGINEER FOR RESOLUTION PRIOR TO THE START OF THE WORK. CONFLICTS RESULTING FROM INACCURATE COORDINATION DRAWINGS AND / OR FAILURE TO IDENTIFY CONFLICTS PRIOR TO INSTALLATION OF THE WORK SHALL BE CORRECTED / ADJUSTED AT THE CONTRACTOR’S EXPENSE AND SHALL RESULT

IN NO ADDITIONAL COST TO THE GOVERNMENT.

G27 CONTRACTOR SHALL, AT ALL TIMES, MAINTAIN EXISTING UTILITY SERVICE TO THE MEDICAL CENTER. IF THE CONTRACTOR’S ABILITY TO PERFORM DEMOLITION ACTIVITIES OR NEW WORK REQUIRES TEMPORARY RELOCATION OF AN EXISTING MEDICAL CENTER UTILITY SERVICE, CONTRACTOR SHALL PROVIDE ALL WORK NECESSARY TO ENSURE CONTINUED OPERATION OF THE UTILITY TO BE RELOCATED. THIS REQUIREMENT APPLIES TO ALL EXISTING UTILITIES

WHETHER OR NOT TEMPORARY RELOCATION IS SPECIFICALLY CALLED OUT ON THE DRAWINGS.

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

ENVIRONMENTAL:

ECS SOUTHEAST

6714 NETHERLANDS DR.

WILMINGTON, NC 28405

POC: AMY DESAIX

T: 901-319-1000

SMEP:

CANNON DESIGN

1560 WILSON BLVD. STE. 200

ARLINGTON, VA 22209

POC: SCOTT PEGLER

T: 703-907-2384

ARCHITECT:

CB DESIGN GROUP

421 KING ST.

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

COST ESTIMATION:

OCMI

6110 EXECUTIVE BLVD. STE. 200

ROCKVILLE, MD 20852

POC: MIKE VELOSE

T: 704-280-8356

TELECOMMUNICATIONS:

SHEN MILSOM WILKE LLC

1220 N. FILLMORE ST. STE. 360

ARLINGTON, VA 22201

POC: GIDEON MAHN

T: 703-721-8039

# REVISION DATE

0 ISSUED FOR CONSTRUCTION 08/24/22

08/24/2022

565-20-103

COKJ

RENOVATE AUDIOLOGY FOR

SPECIALTY CLINICS

100% BID DOCUMENTS

GENERAL NOTES

GI300

-2

-1

G I3

.p d f

FAYETTEVILLE VAMC

2300 RAMSEY ST.

FAYETTEVILLE, NC 28301

HAZARDOUS MATERIALS NOTES

REFERENCES

SMOKING POLICY

NOTE: SEE LIFE SAFETY DRAWINGS FOR SPECIFIC EDITIONS OF APPLICABLE CODES

GENERAL NOTES

MEDICAL WASTE NOTES

EQUIPMENT, PANEL BOARD,

CABINET, OR SIMILAR FEATURE

CRASH RAIL (ALL TYPES), UON

TYPE NO 1 (SHOWN),

TYPE NO 2, OR TYPE

NO 4 CORNER OR

EDGE GUARD

WHERE BUMPER/CRASH

RAILS TERMINATE OR DO

NOT TURN CORNER

BUMPER RAIL

(ALL TYPES),

UON

DOOR FRAME OR

CASED OPENING

FRAME

OUTLET OR SIMILAR

OUTLET OR

SIMILAR WHEN

ADJ TO FRAME

WHERE

BUMPER/CRASH

RAILS TURN

CORNER

CORNER OR

EDGE GUARD

CORNER OR EDGE

GUARD

COMBINATION

HANDRAIL/CRASH

RAIL (ALL TYPES),

UON

WHERE

TERMINATES

WHERE

COMBINATION

HANDRAIL /

CRASH RAIL

TURNS CORNER

DOOR FRAME OR

CASED

OPENING FRAME

CORNER OR EDGE

GUARD

RECESSED CORNER OR EDGE

GUARD EXTENDING FROM

FLOOR TO CEILING OR

HEADER, TYPICAL UNLESS

OTHERWISE NOTED

EQUIPMENT,

PANEL BOARD,

CABINET, OR

SIMILAR FEATURE

2'

0"

U O

N

1'

U O

N

6" 3'

T

Y P

E

2" TYP 2" TYP 2" TYP

4" TYP 4" TYP

2" TYP

2'

0"

T O

P O

F R

A

IL

2" TYP 2" TYP 2" TYP

6" 6'

T Y

P E

N O

S

A N

D

42" TYP 2" TYP 2" TYP

T O

P O

F R

A

IL

2'

0"

6" 6'

T Y

P E

N O

S

A N

D

42" TYP

8" 4" TYP

8"

1'

2"

WP-01 WP-01

CLOCK OR

CLOCK

OUTLET

MANUAL FIRE

ALARM PULL

STATION

LIGHT

SWITCH &

DIMMER

DUPLEX

OUTLET

(LOW)

DUPLEX

OUTLET

(HIGH)

DESK

INTERCOM

OUTLET

INTERCOM

STATION

PHONE/DATA

OUTLET

THERMOSTAT SPECIAL

PURPOSE

OUTLETS

OR

JUNCTION

BOX

SPECIAL

PURPOSE

OUTLETS

DARK ROOM

STATUS LIGHT

SWITCH AT

DOOR OR

CASED OPENING

AUDIBLE

AND/OR VISUAL

FIRE ALARM

SECURITY

STROBE LIGHT

(BLUE LIGHT)

FIREMAN'S

TELEPHONE

JACK

EMERGENCY

STROBE OR

LIGHT

RACEWAY

T O

C O

N T

R O

LS

4'

-0

M A

X H

IG

H

R E

A C

H

3' -0

M

IN

T

O C

O N

T R

O

LS

1' -3

M

IN

L

O W

R E

A C

H

1'

A

LI

G N

W

IT

H T

O P

O F

A D

JA

C

E N

T F

R A

M

E 8" TYP 8" TYP

T O

P O

F B

O X

4'

NURSE CALL

STATION

WITH

CONTROLS

NURSE CALL

STATION

WITHOUT

CONTROLS

5'

NURSE CALL

CORRIDOR

LIGHT (DOME

LIGHT)

DUPLEX OUTLET

ABOVE

COUNTER /

BACKSPLASH

3"

WALL-MTD

TELEPHONE

OUTLET

CARD READER,

LOCAL ALARM,

OR ARMING

STATION

3'

COUNTER

TOP / TOP OF

BACKSPLASH

COAT

HOOKS

(WALL-MTD)

ACCESSIBLE COAT HOOK AT

DOOR/DOOR PARTITION

DOOR (DOOR-MTD)

6"

5'

EQ EQ

6'

T O

C O

N T

R O

LS

4'

-0

M A

X H

IG

H

R E

A C

H

3' -0

M

IN

T

O C

O N

T R

O

LS

1' -3

M

IN

L

O W

R E

A C

H

MEDICAL

GAS ALARM

PANEL

FEC OR

FHV CABINET

1' - 0"

3'

4'

MAX

12"

MIN

42"

40"

P L U

M B

IN

G

W A

L L

6"

MIN

36"

T O

IL

E

T S

ID

E

W A

L L

6" 36"

S

ID

E W

A L L

12"36"

C O

N T

R O

L W

A L

L IF A DOUBLE ROLL

DISPENSER IS PROVIDED,

DIMENSION IS TO ROLL

CLOSEST TO TOILET

TOILET PAPER

DISPENSER

S

ID

E W

A L L

15"

COUNTER

MOUNTED

LAVATORY

S

ID

E W

A L L

15"

WALL

MOUNTED

LAVATORY

C O

U N

T E

R H

E

IG

H T

6"

WALL MOUNTED

POSTURE MIRROR

WALL MOUNTED

MIRROR

T O

R

E F

L E

C T

IN

G

S U

R F

A C

E

18" MIRROR TO

BE 18" X 36" U.N.O

T O

O P

E R

T A

T

IO

N

CENTER

MIRROR

OVER SINK

U.N.O

S H

O W

E R

W A

L L

WALL MOUNTED

SHOWER SEAT

T O

9"

WALL MOUNTED

SOAP DISPENSER

T O

O P

E R

A T

IO

N

S H

O W

E R

W A

L L

T O

IL

E

T C

.L

18"

SWING UP

GRAB BAR

T O

O P

E R

T A

T

IO

N

T O

T O

P

FIRE

EXTINGUISHER IN

FULLY RECESSED CABINET

WALL MOUNTED

MOP HOLDER

T O

F R

O N

T T

P

D G

E O

F D

E C

K

L

IP

W H

N

L

W E

R E

D

WALL MOUNTED

HORIZONTAL

DIAPER CHANGING

STATION

WALL MOUNTED

GRAB BAR

(TOILET SIDE)

WALL MOUNTED

GRAB BAR

(TOILET REAR)

WALL MOUNTED

SHOWER

GRAB BARS

WALL MOUNTED PAPER

TOWEL DISPENSER

(WITH OR WITHOUT

INTEGRAL

TRASH RECEPTICLE)

OR TO TOP OF

RIM, WHICHEVER

IS GREATER.

SWING UP

GRAB BAR

M

IN

FINISHED CEILING

54" MIN MIN

12"

CL

MIN

24"

TRANSFER

SIDE

P L U

M B

IN

G

W A

L L

M

IN

CL

M A

X

3' - 0"

7"-9"

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

ENVIRONMENTAL:

ECS SOUTHEAST

6714 NETHERLANDS DR.

WILMINGTON, NC 28405

POC: AMY DESAIX

T: 901-319-1000

SMEP:

CANNON DESIGN

1560 WILSON BLVD. STE. 200

ARLINGTON, VA 22209

POC: SCOTT PEGLER

T: 703-907-2384

ARCHITECT:

CB DESIGN GROUP

421 KING ST.

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

COST ESTIMATION:

OCMI

6110 EXECUTIVE BLVD. STE. 200

ROCKVILLE, MD 20852

POC: MIKE VELOSE

T: 704-280-8356

TELECOMMUNICATIONS:

SHEN MILSOM WILKE LLC

1220 N. FILLMORE ST. STE. 360

ARLINGTON, VA 22201

POC: GIDEON MAHN

T: 703-721-8039

# REVISION DATE

0 ISSUED FOR CONSTRUCTION 08/24/22

08/24/2022

565-20-103

AuthorChecker

RENOVATE AUDIOLOGY FOR

SPECIALTY CLINICS

100% BID DOCUMENTS

TYPICAL MOUNTING HEIGHTS AND

DIMENSIONING CONVENTIONS

GI301

-2

-1

G I3

/2

/2

.p d f

FAYETTEVILLE VAMC

2300 RAMSEY ST.

FAYETTEVILLE, NC 28301

GENERAL MOUNTING HEIGHT NOTESTYPICAL MOUNTING HEIGHTS AND CLEARANCES

CORNER GUARD / BUMPER RAIL / CRASH RAIL / CORRIDOR HANDRAIL TYPICAL MOUNTING HEIGHTS AND CONFIGURATION DIAGRAMS

A. IT IS THE INTENT OF THE DESIGN THAT ALL ITEMS SHOWN MOUNTED AT TYPICAL HEIGHTS

BE ACCESSIBLE TO PERSONS WITH DISABILITIES.

B. THE PURPOSE OF THIS SHEET IS TO ILLUSTRATE TYPICAL MOUNTING HEIGHTS AND - WHERE

APPLICABLE - TYPICAL MINIMUM OR MAXIMUM CLEARANCES AND/OR TYPICAL MOUNTING

CONFIGURATIONS FOR A VARIETY OF ITEMS. CAUTION: THIS SHEET MAY ILLUSTRATE ITEMS

OR CONFIGURATIONS WHICH DO NOT OCCUR AS PART OF THE WORK OF THIS PROJECT.

REFER TO THE PLANS, ELEVATIONS, SECTIONS, DETAILS, AND SCHEDULES TO DETERMINE

WHICH ITEMS AND CONFIGURATIONS APPLY TO THE WORK OF THIS PROJECT.

C. THE MOUNTING HEIGHTS, CLEARANCES, AND CONFIGURATIONS SHOWN ON THIS SHEET ARE

TYPICAL AND SHALL APPLY TO ALL INSTANCES OF THE ITEM (OR GROUP OF ITEMS) SHOWN

UNLESS SPECIFICALLY NOTED OR DIMENSIONED OTHERWISE.

D. SPECIAL OR NON-TYPICAL MOUNTING HEIGHTS OCCUR ONLY WHERE INDICATED BY

ANNOTATED SYMBOLS; BY KEY NOTES; BY NOTES ON PLANS, ELEVATIONS, OR DETAILS; OR

BY UNIQUE DIMENSIONS ON ELEVATIONS OR DETAILS.

E. MOUNTING CONFIGURATION DIAGRAMS ARE ELEVATIONS WHICH ILLUSTRATE TYPICAL

RULES GOVERNING THE RELATIONSHIPS BETWEEN, AND PLACEMENT OF, ITEMS WHICH

OCCUR IN GROUPS OF RELATED ITEMS OR IN CLOSE PROXIMITY TO OTHER PARTS OF THE

WORK (SUCH AS SWITCHES AND DOOR FRAMES). UNLESS OTHER MOUNTING

CONFIGURATIONS ARE SPECIFICALLY NOTED, DIMENSIONED, OR ELEVATED, THE TYPICAL

RELATIONSHIPS, ARRANGEMENTS, AND THE TYPICAL CONFIGURATION DIAGRAMS APPLY

THROUGHOUT THE WORK OF THIS PROJECT.

UP

UP

UP

DATA CLOSET

B16

OFFICE

B17

OFFICE

B18A

SPEECH

THERAPY

WAITING

B18

SPEECH

THERAPY

B18BOFFICE

B54A

RECEPTION

B54Q

OFFICE

B20

OFFICE

B21

LOCKER ROOM

B22

OFFICE

B54P

EXAM

B54N

TREATMENT

ROOM

B54M

EXAM ROOM

B54L

CORRIDOR

B54I

TREATMENT

ROOM

B54F

EXAM ROOM

B54E

OFFICE

B54D

TREATMENT

ROOM

B54C

AHU-7

MECHANICAL

ROOM

B78

EXAM

B54G/H

ELEC. CL.

B54B

POLICE

DISPATCH

B12

EJ

UP

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

ENVIRONMENTAL:

ECS SOUTHEAST

6714 NETHERLANDS DR.

WILMINGTON, NC 28405

POC: AMY DESAIX

T: 901-319-1000

SMEP:

CANNON DESIGN

1560 WILSON BLVD. STE. 200

ARLINGTON, VA 22209

POC: SCOTT PEGLER

T: 703-907-2384

ARCHITECT:

CB DESIGN GROUP

421 KING ST.

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

COST ESTIMATION:

OCMI

6110 EXECUTIVE BLVD. STE. 200

ROCKVILLE, MD 20852

POC: MIKE VELOSE

T: 704-280-8356

TELECOMMUNICATIONS:

SHEN MILSOM WILKE LLC

1220 N. FILLMORE ST. STE. 360

ARLINGTON, VA 22201

POC: GIDEON MAHN

T: 703-721-8039

# REVISION DATE

0 ISSUED FOR CONSTRUCTION 08/24/22

08/24/2022

565-20-103

COKJ

RENOVATE AUDIOLOGY FOR

SPECIALTY CLINICS

100% BID DOCUMENTS

EXISTING CONDITIONS PLAN -

BASEMENT LEVEL

GC200

-2

-1

G C

/2

/2

.p d f

FAYETTEVILLE VAMC

2300 RAMSEY ST.

FAYETTEVILLE, NC 28301

3/32" = 1'-0"A16

BASEMENT FLOOR PLAN - EXISTING

KEY PLAN

PLAN

NORTH

TRUE

NORTH

NOT TO SCALE

BUILDING 1

B WING

NOT IN SCOPEIN SCOPE

AHU-7

IK1 IK1

IK1IK1

IK2

IK2 IK2

IK2

IK3

IK4

IK5

IK6 IK6IK6

F F F F F F

F

F

F F

EXISTING TREE

EXISTING SHRUB, TYP.

EXISTING MANHOLE

IK7

M

IN

3'

R3.1t R3.1tR3.1tR3.1t B18t

B54At

B B tB20t

B17t

UP

CONSTRUCTION

PROJECT TYPE

A B C D

LOW I II II III/IV

MEDIUM I II III IV

HIGH I II III/IV IV

HIGHEST II III/IV III/IV IV

PATIENT

RISK

GROUP

NOTE: ICRA

CLASSIFICATION

SUBJECT TO CHANGE

PER VA INFECTION

CONTROL NURSE.

DATA CLOSET

B16

OFFICE

B17

OFFICE

B18A

SPEECH

THERAPY

WAITING

B18

SPEECH

THERAPY

B18B

OFFICE

B54A

RECEPTION

B54Q

OFFICE

B20

OFFICE

B21

LOCKER ROOM

B22

OFFICE

B54P

EXAM

B54N

TREATMENT

ROOM

B54M

EXAM ROOM

B54L

CORRIDOR

B54I

TREATMENT

ROOM

B54F

EXAM ROOM

B54E

OFFICE

B54D

TREATMENT

ROOM

B54C

EXAM

B54G/H

ELEC. CL.

B54B

DEBRIS

REMOVAL ROUTE

AREA NOT IN

SCOPE

ABOVE CEILING

DEMOLITION

AREA

ICRA BARRIER

CONSTRUCTION

FENCE

KEYNOTE TAG

F

IK1

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

ENVIRONMENTAL:

ECS SOUTHEAST

6714 NETHERLANDS DR.

WILMINGTON, NC 28405

POC: AMY DESAIX

T: 901-319-1000

SMEP:

CANNON DESIGN

1560 WILSON BLVD. STE. 200

ARLINGTON, VA 22209

POC: SCOTT PEGLER

T: 703-907-2384

ARCHITECT:

CB DESIGN GROUP

421 KING ST.

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

COST ESTIMATION:

OCMI

6110 EXECUTIVE BLVD. STE. 200

ROCKVILLE, MD 20852

POC: MIKE VELOSE

T: 704-280-8356

TELECOMMUNICATIONS:

SHEN MILSOM WILKE LLC

1220 N. FILLMORE ST. STE. 360

ARLINGTON, VA 22201

POC: GIDEON MAHN

T: 703-721-8039

# REVISION DATE

0 ISSUED FOR CONSTRUCTION 08/24/22

08/24/2022

565-20-103

COKJ

RENOVATE AUDIOLOGY FOR

SPECIALTY CLINICS

100% BID DOCUMENTS

ICRA PLAN

GC400

-2

-1

G C

/2

/2

.p d f

FAYETTEVILLE VAMC

2300 RAMSEY ST.

FAYETTEVILLE, NC 28301

3/32" = 1'-0"A16

BASEMENT FLOOR PLAN - ICRA CONSTRUCTION

KEY PLAN

PLAN

NORTH

TRUE

NORTH

NOT TO SCALE

BUILDING 1

B WING

NOT IN SCOPEIN SCOPE

ICRA NOTES - CONSTRUCTION

IC1 ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION

OF DUCT SYSTEM.

IC2 COMPLETE ALL CRITICAL BARRIERS (I.E. SHEETROCK, PLYWOOD, & PLASTIC) TO SEAL AREA

FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH PLASTIC

COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR VACUUMING

PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.

IC3 MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR

FILTRATION UNITS. AIR PRESSURE SHALL BE CONTINUOUSLY MONITORED. THE

CONTRACTOR SHALL USE TEMPORARY PRESSURE SENSORS CONNECTED TO THE BUILDING

AUTOMATION SYSTEM (BAS) VIA AHU-7 CONNECTION. THE CONTRACTOR SHALL TRACK,

TREND, AND ALARM PROJECT AREA PRESSURE TO ENSURE PROOF OF NEGATIVE PRESSURE

ENVIRONMENT AT ALL TIMES UNTIL APPROVED BY VA COR TO REMOVE.

IC4 SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES AIRTIGHT AND/OR FIRE SEAL AS REQUIRED.

IC5 CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH THIS ROOM SO

THEY CAN BE VACUUMED USING A HEPA VACUUM CLEANER BEFORE LEAVING WORK SITE OR

THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH TIME THEY LEAVE

THE WORK SITE.

IC6 ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS. SHOE

COVERS MUST BE CHANGED EACH TIME THE WORKER EXITS THE WORK AREA.

IC7 DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS APPROVED BY

THE COR, INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION CONTROL

DEPARTMENT AND THOROUGHLY CLEANED BY THE OWNER'S ENVIRONMENTAL SERVICES

DEPARTMENT.

IC8 REMOVE CONSTRUCTION WASTE DAILY DURING THE HOURS OUTSIDE OF 0800-1630.

IC9 CONTRACTOR TO USE ROUTE AGREED UPON BY THE ICRA TEAM AND COR FOR TRANSPORT

OF CONTAINERS THROUGH THE FACILITY.

IC10 PLACE DUST MATS AT ENTRANCE AND EXIT OF WORK AREA.

ICRA NOTES - REMOVAL

IR1 REMOVE BARRIER MATERIAL CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS

ASSOCIATED WITH CONSTRUCTION.

IR2 CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.

IR3 COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.

IR4 VACUUM WORK AREA WITH HEPA FILTERED VACUUMS.

IR5 WET MOP AREA WITH DISINFECTANT. VA COR SHALL APPROVE DISINFECTANT.

IR6 REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.

ICRA NOTES - GENERAL

IG1 PROVIDE TEMPORARY / PERMANENT RATED ICRA PARTITIONS AS CONCEPTUALLY INDICATED

ON PLANS. CONTRACTOR SHALL SUBMIT AN ICRA PLAN FOR APPROVAL OF THE COR PRIOR

TO BEGINNING ANY WORK.

IG2 DOORS IN ICRA PARTITIONS SHALL HAVE CLOSERS, PANIC DEVICES, STOREROOM FUNCTION

LOCKS, AND ALARMS. DOORS SHALL AUTOMATICALLY LOCK UPON CLOSURE.

IG3 CONTRACTOR SHALL INSTALL "CONSTRUCTION ZONE - AUTHORIZED PERSONNEL ONLY" SIGN

ON THE PUBLIC SIDE OF ALL ICRA DOORS.

IG4 ALL ICRA PARTITIONS SHALL BE WALL TYPE "R3.1t". REFER TO AE301 FOR MORE

INFORMATION.

IG5 CONTRACTOR SHALL COMPLY WITH NFPA 241 FOR DURATION OF DEMOLITION AND

CONSTRUCTION.

ICRA MATRIX

ICRA NOTES - KEYNOTES

IK1 AIRTIGHT ANTEROOM. CONTRACTOR SHALL MAINTAIN 44" CLEAR IN CORRIDOR OUTSIDE.

IK2 TEMPORARY WALK-OFF MAT

IK3 HEPA FILTER EXHAUST FAN SYSTEM VENTED THROUGH EXISTING WINDOW. CONTRACTOR

SHALL VERIFY LOCATION WITH COR.

IK4 CONTRACTOR ENTRANCE AND DEBRIS REMOVAL DOOR.

IK5 CONSTRUCTION LAYDOWN/STAGING AREA. CONTRACTOR SHALL CONFIRM EXTENTS WITH

COR. SEE SITE PLAN FOR INFORMATION ON SEEDING/SODDING.

IK6 DOTTED AREA INDICATES AREA WHERE ABOVE-CEILING DEMOLITION SHALL OCCUR.

DEMOLITION IN THIS AREA SHALL OCCUR OUTSIDE OF BUSINESS HOURS. CONTRACTOR

SHALL SUBMIT FOR VA INFECTION CONTROL NURSE APPROVAL PLANS BEFORE

ACCOMPLISHING ANY WORK IN THESE AREAS.

IK7 CONSTRUCTION FENCE POSTS SHALL BE SET IN CONCRETE FOOTINGS ACCORDING TO

MANUFACTURER'S RECOMMENDATIONS. REFERENCE TO 010000 GENERAL REQUIREMENTS

FOR MORE INFORMATION ABOUT CONSTRUCTION FENCE.

LEGEND

OFFICE

B18

INTAKE

HALL

49 SF

WAITING

ROOM TOILET

B27B

ELECTRICAL

ROOM

B17

EXAM HALL

PATIENT

TOILET

(BARIATRIC)

B28

TEAM ROOM

B19

BREAK ROOM

B19B

STAFF TOILET

B19ACLEAN

SUPPLY

B35

EMS / SOILED

UTILITY

B34

CLEAN UTILITY

B33

PATIENT

STORAGE

B32

OBSERVATION

ROOM

B31

OBSERVATION

ROOM

B20

OBSERVATION

ROOM

B30

PATIENT

TOILET

B21

NURSE

STATION

B22

OBSERVATION

ROOM

(BARIATRIC)

B29

EXAM ROOM

B23

OBSERVATION

ROOM HALL

TRIAGE

B24

WAITING

ROOM

B27

RECEPTION

B26

SALLY PORT

B27A

EXAM ROOM

B25

MEDICATION

ROOM

B22A

IF300

IF300

4 4 4 4

PSRA MATRIX

Patient Safety Risk Assesment

SELF-HARM

NOT ANTICIPATED

LEVEL II LEVEL IV

LEVEL I LEVEL III

ACTIVELY

SUICIDAL

IN

T

E N

T F

O R

S E

L F

-H A

R M

1:1 OBSERVATION COMPLETELY ALONE

RESIDENTIAL

INSTITUTIONAL

C H

A R

A C

T E

R

OPPORTUNITY FOR SELF-HARM

LEVEL V

UNKNOWN

RISK

VA Project Number:

Building:

Drawing Number:

Project Title:

Project Location:

Issue Date:

Checked By: Drawn By:

Drawing Title:

FULLY

SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF RECORD:CONSULTANTS:

/8

/4

/8

/2

/4

-1

/2

ENVIRONMENTAL:

ECS SOUTHEAST

6714 NETHERLANDS DR.

WILMINGTON, NC 28405

POC: AMY DESAIX

T: 901-319-1000

SMEP:

CANNON DESIGN

1560 WILSON BLVD. STE. 200

ARLINGTON, VA 22209

POC: SCOTT PEGLER

T: 703-907-2384

ARCHITECT:

CB DESIGN GROUP

421 KING ST.

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL SEAL:

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

COST ESTIMATION:

OCMI

6110 EXECUTIVE BLVD. STE. 200

ROCKVILLE, MD 20852

POC: MIKE VELOSE

T: 704-280-8356

TELECOMMUNICATIONS:

SHEN MILSOM WILKE LLC

1220 N. FILLMORE ST. STE. 360

ARLINGTON, VA 22201

POC: GIDEON MAHN

T: 703-721-8039

# REVISION DATE

0 ISSUED FOR CONSTRUCTION 08/24/22

08/24/2022

565-20-103

AuthorChecker

RENOVATE AUDIOLOGY FOR

SPECIALTY CLINICS

100% BID DOCUMENTS

PSRA MATRIX

GC500

-2

-1

G C

/2

/2

.p d f

FAYETTEVILLE VAMC

2300 RAMSEY ST.

FAYETTEVILLE, NC 28301

3/16" = 1'-0"A15

BASEMENT LEVEL FLOOR PLAN - RISK AREAS

KEY PLAN

PLAN

NORTH

TRUE

NORTH

NOT TO SCALE

BUILDING 1

PATIENT

TOILET

(BARIATRIC)

B28

WAITING

ROOM TOILET

B27B

INTAKE HALL

ELECTRICAL

ROOM

B17

OFFICE

B18

TEAM ROOM

B19

PA

TH

T O

E

XI

T

'-1 0"

PA

TH

T O

E

XI

T

3' -0

DOOR

3' - 6"

210 10

DOOR

5' - 4"

320 10

2 HOUR BUILDING SEPERATION

HORIZONTAL EXIT

DOOR

3' - 4"

134 45

BUSINESS

HEALTHCARE

BUSINESS

HEALTHCARE

FEC

EXAM HALL

HEALTHCARE SUITE

SLEEPING

2,314 SF

OBSERVATION

ROOM

B20

PATIENT

TOILET

B21

OBSERVATION

ROOM

B30

OBSERVATION

ROOM

B31

OBSERVATION

ROOM

(BARIATRIC)

B29

NURSE

STATION

B22

EXAM ROOM

B23

TRIAGE

B24

EXAM ROOM

B25RECEPTION

B26

WAITING

ROOM

B27

SALLY PORT

B27A

STAFF TOILET

B19A BREAK ROOM

B19B

CLEAN

SUPPLY

B35

EMS / SOILED

UTILITY

B34

CLEAN UTILITY

B33

PATIENT

STORAGE

B32

CODE ANALYSIS LEGEND

1 HOUR FIRE BARRIER PER NFPA 101 SECTION

7.3. OPENINGS FIRE RATED FOR 45 MINUTES

UNLESS SHAFT, EXIT ENCLOSURE, OR EXIT

PASSAGEWAY WALLS WHICH REQUIRE 1 HOUR

RATED OPENINGS.

2 HOUR FIRE BARRIER PER NFPA 101 SECTION

7.3. OPENINGS FIRE RATED FOR 90 MINUTES.

EGRESS PATH WITH NAME, SEGMENT LENGTH,

AND DIRECTION INDICATEDPATH

DOOR/STAIR INDICATORS

DOOR

0"

WIDTH

EXPECTED EGRESS

CAPACITY

WIDTH

ACTUAL EGRESS

CAPACITY

DOOR/STAIR ID

OPENING RATING IN

OPENING RATING IN

FEC FIRE EXTINGUISHER CABINET

*NOTE: AS DEPICTED ON THE

SHEET, ALL FIRE EXTINGUISHER

CABINETS MEET MIN. 75 FT

REQUIREMENTS

EXIT SIGN

HEALTHCARE SUITE

NFPA 101 LIFE SAFETY CODE 2018 OUTPATIENT BEHAVIORAL HEALTH

THE OUTPATIENT BEHAVIORAL HEALTH AREA WILL HAVE THE ABILITY TO SEQUESTER UP

TO (4) PATIENTS IN THE ROOM MAKING THE PATIENTS INCAPABLE OF SELF-

PRESERVATION. PATIENTS CAN STAY IN THE ROOMS FOR MULTIPLE DAYS. THE PATIENT

AREA IS BEING EVALUATED AS CHAPTER 18: NEW HEALTHCARE, SEPARATED FROM THE

EXISTING BUSINESS OCCUPANCY BY A 2-HOUR BARRIER AND DESIGNATED AS A SLEEPING

SUITE.

BUILDING TYPE TYPE I (332)

TOTAL PROJECT AREA 1,344 SF – Business 2,314 SF – Healthcare 3,658 SF Total

TOTAL FLOOR AREA GROSS FLOOR AREA (100%

ALL SPACES): 3,310 SF

OCCUPANCY COUNT HEALTH CARE USE,

SLEEPING DEPARTMENTS:

2,314 SF / 120 SF PER

BUSINESS USE:

1,344 SF / 30 SF PER

OCCUPANTS HEALTHCARE = 20

BUSINESS = 45

EGRESS CAPACITY PROVIDED

HEALTHCARE EXIT DOOR: 42" DOOR 42/.2

=210 OCCUPANTS MAX.

HORZ EXIT DOOR: 64”/.2

= 320 OCCUPANTS MAX.

BUSINESS EXIT DOOR: 42" DOOR 42/.2

=210 OCCUPANTS MAX.

CORRIDOR MINIMUM 72" ALLOWED BY

VA STANDARDS

82" EXISTING EXIT CORRIDORS

7.1.10 MEANS OF EGRESS RELIABILITY

7.1.10.1 MEANS OF EGRESS SHALL BE CONTINUOUSLY MAINTAINED FREE OF ALL

OBSTRUCTIONS OR IMPEDIMENTS TO FULL INSTANT USE IN THE CASE OF FIRE OR

OTHER EMERGENCY.

9.2.1 AIR CONDITIONING, HEATING, VENTILATION DUCTWORK, AND RELATED EQUIPMENT.

AIR CONDITIONING, HEATING, VENTILATION DUCTWORK, AND RELATED EQUIPMENT SHALL

BE IN ACCORDANCE WITH NFPA 90A.

18.1.2 CLASSIFICATION OF OCCUPANCY

18.1.3 MULTIPLE OCCUPANCIES

18.1.3.1

MULTIPLE OCCUPANCIES SHALL BE IN ACCORDANCE WITH 6.1.14.

18.1.3.5.1

AMBULATORY CARE FACILITIES, MEDICAL CLINICS, AND SIMILAR FACILITIES THAT ARE

CONTIGUOUS TO HEALTH CARE OCCUPANCIES, BUT ARE PRIMARILY INTENDED TO

PROVIDE OUTPATIENT SERVICES, SHALL BE PERMITTED TO BE CLASSIFIED AS BUSINESS

OCCUPANCIES OR AMBULATORY HEALTH CARE FACILITIES, PROVIDED THAT THE

FACILITIES ARE SEPARATED FROM THE HEALTH CARE OCCUPANCY BY CONSTRUCTION

HAVING A MINIMUM 2-HOUR FIRE RESISTANCE RATING, AND THE FACILITY IS NOT

INTENDED TO PROVIDE SERVICES SIMULTANEOUSLY FOR FOUR OR MORE INPATIENTS

WHO ARE INCAPABLE OF SELF PRESERVATION.

18.1.3.5.2

AMBULATORY CARE FACILITIES, MEDICAL CLINICS, AND SIMILAR FACILITIES THAT ARE

CONTIGUOUS TO HEALTH CARE OCCUPANCIES SHALL BE PERMITTED TO BE USED FOR

DIAGNOSTIC AND TREATMENT SERVICES OF INPATIENTS WHO ARE CAPABLE OF SELF-

PRESERVATION.

18.1.3.7

ALL MEANS OF EGRESS FROM HEALTH CARE OCCUPANCIES THAT TRAVERSE NON-HEALTH

CARE SPACES SHALL CONFORM TO THE REQUIREMENTS OF THIS CODE FOR HEALTH CARE

OCCUPANCIES, UNLESS OTHERWISE PERMITTED BY 18.1.3.8.

18.1.3.8

EXIT THROUGH A HORIZONTAL EXIT INTO OTHER CONTIGUOUS OCCUPANCIES THAT DO

NOT CONFORM TO HEALTH CARE EGRESS PROVISIONS, BUT THAT DO COMPLY WITH

REQUIREMENTS SET FORTH IN THE APPROPRIATE OCCUPANCY CHAPTER OF THIS CODE,

SHALL BE PERMITTED, PROVIDED THAT BOTH OF THE FOLLOWING CRITERIA APPLY:

• (1) THE OCCUPANCY DOES NOT CONTAIN HIGH HAZARD CONTENTS.

• (2) THE HORIZONTAL EXIT COMPLIES WITH THE REQUIREMENTS OF 18.2.2.5.

18.2.2.2 DOORS

18.2.2.2.4 DOORS WITHIN A REQURIED MEANS OF EGRESS SHALL NOT BE EQUIPPED

WITH A LATCH OR LOCK THAT REQUIRES THE USE OF A TOOL OR KEY FROM THE EGRESS

SIDE, UNLESS OTHERWISE PERMITTED BY ONE OF THE FOLLOWING:

EXCEPTION NO. 1: KEY-LOCKING DEVICES THAT RESTRICT ACCESS TO THE ROOM

FROM THE CORRIDOR AND THAT ARE OPERABLE ONLY BY STAFF FROM THE CORRIDOR

SIDE SHALL BE PERMITTED. SUCH DEVICES SHALL NOT RESTRICT EGRESS FROM THE

ROOM.

18.2.2.2.5.1

DOOR-LOCKING ARRANGEMENTS SHALL BE PERMITTED WHERE THE CLINICAL NEEDS OF

PATIENTS REQUIRE SPECIALIZED SECURITY MEASURES OR WHERE PATIENTS POSE A

SECURITY THREAT, PROVIDED THAT STAFF CAN READILY UNLOCK DOORS AT ALL TIMES IN

ACCORDANCE WITH 18.2.2.2.6.

18.2.2.2.6

DOORS THAT ARE LOCATED IN THE MEANS OF EGRESS AND ARE PERMITTED TO BE

LOCKED UNDER OTHER PROVISIONS OF 18.2.2.2.5 SHALL COMPLY WITH BOTH OF THE

FOLLOWING:

(1) PROVISIONS SHALL BE MADE FOR THE RAPID REMOVAL OF OCCUPANTS BY MEANS OF

ONE OF THE FOLLOWING:

(A) REMOTE CONTROL OF LOCKS FROM WITHIN THE LOCKED SMOKE COMPARTMENT

(B) KEYING OF ALL LOCKS TO KEYS CARRIED BY STAFF AT ALL TIMES

(C)OTHER SUCH RELIABLE MEANS AVAILABLE TO THE STAFF AT ALL TIMES

(2) ONLY ONE LOCKING DEVICE SHALL BE PERMITTED ON EACH DOOR.

18.2.2.5 HORIZONTAL EXITS

HORIZONTAL EXITS COMPLYING WITH 7.2.4 AND THE MODIFICATIONS

OF 18.2.2.5.1 THROUGH 18.2.2.5.7 SHALL BE PERMITTED.

CODE DATA

18.2.3.1

THE CAPACITY OF MEANS OF EGRESS SHALL BE IN ACCORDANCE WITH SECTION 7.3

7.3 / TABLE 7.3.3.1 THE CAPACITY OF MEANS OF EGRESS PROVIDING TRAVEL BY MEANS OF

STAIRS SHALL BE 0.3 IN. PER PERSON, AND THE CAPACITY OF MEANS OF EGRESS PROVIDING

HORIZONTAL TRAVEL (WITHOUT STAIRS) BY MEANS SUCH AS DOORS, RAMPS, OR HORIZONTAL

EXITS SHALL BE 0.2 IN. PER PERSON.

18.2.3.4

AISLES, CORRIDORS, AND RAMPS REQUIRED FOR EXIT ACCESS IN A HOSPITAL OR NURSING

HOME SHALL BE NOT LESS THAN 8 FT IN CLEAR AND UNOBSTRUSCTED WIDTH.

18.2.5 ARRANGEMENT OF MEANS OF EGRESS

18.2.5.2 DEAD-END CORRIDORS. DEAD-END COORIDORS SHALL NOT EXCEED 30 FT

18.2.5.6.1 EVERY HABITABLE ROOM SHALL HAVE AN EXIT ACCESS DOOR LEADING DIRECTLY TO

AN EXIT ACCESS CORRIDOR

18.2.5.7.1.1 SUITE PERMISSION

SUITES COMPLYING WITH 18.2.5.7 SHALL BE PERMITTED TO BE USED TO MEET THE CORRIDOR

ACCESS REQUIREMENTS OF 18.2.5.6.

18.2.5.7.1.2 SUITE SEPARATION

SUITES SHALL BE SEPARATED FROM THE REMAINDER OF THE BUILDING, AND FROM OTHER

SUITES, BY WALLS AND DOORS MEETING THE REQUIREMENTS OF 18.3.6.2 THROUGH 18.3.6.5.

18.2.5.7.2 SLEEPING SUITES

SLEEPING SUITES SHALL BE IN ACCORDANCE WITH THE FOLLOWING:

(1) SLEEPING SUITES FOR PATIENT CARE SHALL COMPLY WITH THE PROVISIONS

OF 18.2.5.7.2.1 THROUGH 18.2.5.7.2.4.18.2.5.7.2.1 SLEEPING SUITE SUPERVISION.

(A) SLEEPING SUITES SHALL BE PROVIDED WITH CONSTANT STAFF SUPERVISION WITHIN

THE SUITE.

(B) SLEEPING SUITES SHALL BE ARRANGED IN ACCORDANCE WITH ONE OF THE

FOLLOWING:

(2) PATIENT SLEEPING ROOMS WITHIN SLEEPING SUITES SHALL PROVIDE ONE OF THE

FOLLOWING:

(A)THE PATIENT SLEEPING ROOMS SHALL BE ARRANGED TO ALLOW FOR DIRECT

SUPERVISION FROM A NORMALLY ATTENDED LOCATION WITHIN THE SUITE, SUCH AS IS

PROVIDED BY GLASS WALLS, AND CUBICLE CURTAINS SHALL BE PERMITTED.

(B)ANY PATIENT SLEEPING ROOMS WITHOUT THE DIRECT SUPERVISION REQUIRED

BY 18.2.5.7.2.1(B)(1)(A) SHALL BE PROVIDED WITH SMOKE DETECTION IN ACCORDANCE

WITH SECTION 9.6 AND 18.3.4.

(3) SLEEPING SUITES SHALL BE PROVIDED WITH A TOTAL (COMPLETE) COVERAGE AUTOMATIC

SMOKE DETECTION SYSTEM IN ACCORDANCE WITH 9.6.2.9 AND 18.3.4.

18.2.5.7.2.2 SLEEPING SUITE MEANS OF EGRESS

(A) SLEEPING SUITES SHALL HAVE EXIT ACCESS TO A CORRIDOR COMPLYING WITH 18.3.6 OR

TO A HORIZONTAL EXIT, DIRECTLY FROM THE SUITE.

(B) SLEEPING SUITES OF MORE THAN 1000 FT2 (93 M2) SHALL HAVE NOT LESS THAN TWO EXIT

ACCESS DOORS REMOTELY LOCATED FROM EACH OTHER.

(C) FOR SUITES REQUIRING TWO EXIT ACCESS DOORS, ONE OF THE EXIT ACCESS DOORS

FROM THE SUITE SHALL BE PERMITTED TO BE TO ONE OF THE FOLLOWING:

(1) AN EXIT STAIR

(2) AN EXIT PASSAGEWAY

(3) AN EXIT DOOR TO THE EXTERIOR

(4) ANOTHER SUITE, PROVIDED THAT THE SEPARATION BETWEEN THE SUITES COMPLIES

WITH THE CORRIDOR REQUIREMENTS OF 18.3.6.2 THROUGH 18.3.6.5

18.2.5.7.2.3 SLEEPING SUITE MAXIMUM SIZE

(B) SLEEPING SUITES SHALL NOT EXCEED 7500 FT2 (700 M2), UNLESS OTHERWISE PROVIDED

IN 18.2.5.7.2.3(C).

18.2.5.7.2.4 SLEEPING SUITE TRAVEL DISTANCE.

(A) TRAVEL DISTANCE BETWEEN ANY POINT IN A SLEEPING SUITE AND AN EXIT ACCESS DOOR

TO ANOTHER SUITE, AN EXIT ACCESS CORRIDOR DOOR, OR A HORIZONTAL EXIT DOOR FROM

THAT SUITE SHALL NOT EXCEED 100 FT (30 M).

(B) TRAVEL DISTANCE BETWEEN ANY POINT IN A SLEEPING SUITE AND AN EXIT SHALL NOT

EXCEED 200 FT (61 M).

18.2.6 TRAVEL DISTANCE TO EXITS

18.2.6.2.1 THE TRAVEL DISTANCE BETWEEN ANY POINT IN A ROOM AND AN EXIT SHALL NOT

EXCEED 200 FT.

18.2.6.2.3 THE TRAVEL DISTANCE BETWEEN ANY POINT IN A HEALTH CARE SLEEPING ROOM

AND AN EXIT ACCESS DOOR IN THAT ROOM SHALL NOT EXCEED 50 FEET.

18.3 PROTECTION.

18.3.4.1 GENERAL. HEALTH CARE OCCUPANCIES SHALL BE PROVIDED WITH A FIRE ALARM

SYSTEM IN ACCORDANCE WITH SECTION 9.6.

18.3.4.3.1 OCCUPANT NOTIFICATION. OCCUPANT NOTIFICATION SHALL BE ACCOMPLISHED

AUTOMATICALLY IN ACCORDANCE WITH 9.6.3.

18.3.4.5 DETECTION

18.3.4.5.1 GENERAL. DETECTION SYSTEMS, WHERE REQUIRED, SHALL BE IN ACCORDANCE

WITH SECTION 9.6.

18.3.5.1 BUILDINGS CONTAINING HEALTH CARE FACILITIES SHALL BE PROTECTED

THROUGHOUT BY AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN

ACCORDANCE WITH SECTION 9.7.

18.3.5.6 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN ALL HEALTH CARE

OCCUPANCIES IN ACCORDANCE WITH 9.7.4.1.

18.3.6 CORRIDORS

18.3.6.1 CORRIDORS SHALL BE SEPARATED FROM ALL OTHER AREAS BY PARTITIONS.

18.3.6.2 CONSTRUCTION OF CORRIDOR WALLS SHALL FORM A BARRIER TO LIMIT THE

TRANSFER OF SMOKE. SUCH WALLS SHALL BE PERMITTED TO TERMINATE AT THE CEILING

WHERE THE CEILING IS CONSTRUCTED TO LIMIT THE TRANSFER OF SMOKE. NO FIRE

RESISTANCE RATING REQUIRED FOR CORRIDOR WALLS.

18.3.6.3 CORRIDOR DOORS

18.3.6.3.1 CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE.

18.3.6.3.2 PROVIDED WITH POSITIVE LATCHING.

18.3.6.3.11 DOOR-CLOSING DEVICES SHALL NOT BE REQUIRED ON DOORS IN CORRIDOR WALL

OPENINGS OTHER THAN THOSE SERVING REQUIRED EXITS, SMOKE BARRIERS, OR

ENCLOSURES OF VERTICAL OPENINGS AND HAZARDOUS AREAS

18.3.7.1 (4) TO LIMIT THE TRAVEL DISTANCE FROM ANY POINT TO REACH A DOOR IN THE

REQUIRED SMOKE BARRIER TO A DISTANCE NOT EXCEEDING 200 FEET.

VA Project

Building:

Drawing

Project

Project

Issue

Checked Drawn By:

Drawing

FULLY

SPRINKLER

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

A

Submission:

ARCHITECT / ENGINEER OF

Revision Dat

CONSULTANTS:

/8

'-0

4 '

8 ' 6 '

/4

'-0

/8

'-0

/2

'-0

/4

'-0

'-0

-1

/2

'-0

'-0

ENVIRONMENTAL:

ECS SOUTHEAST

6714 NETHERLANDS

DR.

WILMINGTON, NC

28405

SMEP:

CANNON DESIGN

1560 WILSON BLVD. STE.

ARLINGTON, VA 22209

POC: SCOTT PEGLER

ARCHITECT:

CB DESIGN GROUP

421 KING ST.

SUITE 301

ALEXANDRIA, VA 22314

703-772-4213

PROFESSIONAL

2345678910111213141516

B

C

D

E

F

G

H

I

J

12345678910111213141516

DRAWINGS NOT INTENDED FOR

CONSTRUCTION.

COST ESTIMATION:

OCMI

6110 EXECUTIVE BLVD.

STE. 200

ROCKVILLE, MD 20852

POC: MIKE VELOSE

08/24/2022

565-20-103

JGJG

RENOVATE AUDIOLOGY FOR

SPECIALTY CLINICS

100% BID DOCUMENTS

CODE ANALYSIS / LIFE SAFETY PLAN

LS-100

5-

-1

. L

S-

0.

0/

/2 0.

pd f

FAYETTEVILLE VAMC

2300 RAMSEY ST.

FAYETTEVILLE, NC 28301

1/8" = 1'-0"1 LIFE SAFETY PLAN

KEY PLAN

PLAN

NORTH

TRUE

NORTH

NOT TO SCALE

SCOPE

OF WORK

RENOVATION

EXISTING

BUILDING

PLAN

NORTH

TRUE

NORTH

23 23

1 2.4 2.3 2.5 3

P

O

N

M

1 1 16 6

8 8 8 8 8 8

Q

4 5T

9 9 99 9

A8

AD100

1 2.4 2.3 2.5 3

P

O

N

M

8 8 8 8 8 8

Q

4 5T

DATA CLOSET

B16

OFFICE

B17

OFFICE

B18A

SPEECH

THERAPY

WAITING

B18

SPEECH

THERAPY

B18B

OFFICE

B54A

RECEPTION

B54Q

OFFICE

B20

OFFICE

B21

LOCKER ROOM

B22

OFFICE

B54P

EXAM

B54N

TREATMENT

ROOM

B54M

EXAM ROOM

B54L

CORRIDOR

B54I

TREATMENT

ROOM

B54F

EXAM ROOM

B54E

OFFICE

B54D

TREATMENT

ROOM

B54C

EXAM

B54G/H

ELEC. CL.

B54B

DATA CLOSET

B16

OFFICE

B17

OFFICE

B18A

SPEECH

THERAPY

WAITING

B18

SPEECH

THERAPY

B18B

OFFICE

B54A

RECEPTION

B54Q

OFFICE

B20

OFFICE

B21

LOCKER ROOM

B22

OFFICE

B54P

EXAM

B54N

TREATMENT

ROOM

B54M

EXAM ROOM

B54L

CORRIDOR

B54I

TREATMENT

ROOM

B54F

EXAM ROOM

B54E

OFFICE

B54D

TREATMENT

ROOM

B54C

EXAM

B54G/H

ELEC. CL.

B54B

CEILING SYSTEM TO

BE DEMOLISHED

EXISTING CONSTRUCTION

TO REMAIN

AREA NOT IN SCOPE

DEMOLITION PLAN LEGEND

BUILDING ELEMENT TO BE

DEMOLISHED

KEYNOTE TAG BUILDING ELEMENT TO BE

SALVAGED AND RETURNED TO VA

BASEMENT

0' - 0"

FIRST LEVEL

11' - 11"

SECOND LEVEL

24' - 3"

EXISTING BRICK WALL TO REMAIN

EXISTING WINDOWS TO REMAIN

EXISTING STONE MASONRY WALL TO REMAIN

EXISTING AWNING TO REMAIN

EXISTING STEPS TO BE DEMOLISHED

EXISTING DOOR AND FRAME TO BE

DEMOLISHED

EXISTING MASONRY BELOW EXISTING

DOOR TO BE REMOVED

VA Project Number:

Building:

Drawing Number:

Project…

This is the start of the file's text. The full file is on GovTribe.