SECS-RI34.0: Oklahoma City Tote/Package Conveyor Interface
The Oklahoma City Tote/Package Conveyor Interface establishes communications between the ECS and the Oklahoma City Tote/Package Conveyor System.
Communications protocol – RS-232 Serial ASCII-7 bit 9600-Baud Asynchronous No ACK’s or NAK’s (acknowledgments) or check-sums will be sent. Messages will end in a carriage return. Mis-reads will be represented by question marks. Internal message from AWOS to Tote Package will be called T48 message.
Oklahoma City Tote/Package Conveyor Host (ECS) to Tote/Package Conveyor Message Formats
TABLE 1: Tote/Package Conveyor Host to Tote/Package Conveyor Message Formats
| MESSAGE TYPE |
| MESSAGE DESCRIPTION |
| MESSAGE FORMAT |
| Move Msg for PPP&M Receiving, Packing |
| Movement command of package |
| STX – Start of Text |
Scanner Number – Char 2 Destination – Char 7 CR – Carriage Return
| Move Msg for Storage |
| Movement command of package |
| STX – Start of Text |
Scanner Number – Char 2 Destination – Char 8 CR – Carriage Return
| Move Msg for Shipping |
| Movement command of package |
| STX – Start of Text |
Scanner Number – Char 2 Destination – Char 7 CR – Carriage Return LF – Line Feed