INVENTORY - Reg C 24R1000.xlsx
XLSX spreadsheet 188 KB Posted
- Solicitation number
- W912HP24R1000
About this file
This document provides an inventory of facilities and equipment for a federal agency. It includes details on various HVAC, electrical, plumbing, and fire protection systems across multiple buildings and sites. Key information includes identification and specifications for air handling units, chillers, boilers, pumps, controls systems, lighting fixtures, kitchen equipment, overhead doors, gates, and other infrastructure assets. Serial numbers, manufacturer names and models are provided where available. The level of detail would aid in maintenance, repair, and capital planning activities for the agency's real property portfolio.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMD0001 PWS - Reg C 24R1000.pdf | ||
| AMD0001 ELINS_J 0200000 07 Exhibit Line Item Numbers_Reg C.xlsx | XLSX spreadsheet | |
| AMD0001 W912HP24R1000 81st RD FIS Region C.pdf | ||
| ELINS_J 0200000 07 Exhibit Line Item Numbers_Reg C.xlsx | XLSX spreadsheet | |
| PWS - Reg C 24R1000.pdf | ||
| B. RFP W912HP24R1000 81st FIS Region C.pdf | ||
| SITE VISIT SCHEDULE - Reg C 24R1000.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Region C Inventory
| Region | FACID | Bldg # | Funding | PWS Paragraph | Description | Extended Description | Location | Quantity | Barcode | Label | Manufacturer | Model # | Serial Number | Comments |
| C | AL028 | AL028-3150 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Air Cooled Chiller | 1 | Air Cooled Chiller | Trane | CGAFC504ARA1 | C09H02311 | |||
| C | AL028 | AL028-3150 | DPW | 3.2.01 | HVAC and Refrigeration Systems | AHU-1 | Mechancial Room | 1 | AHU-1 | Trane | CCDB14AENC | K83J03523 | ||
| C | AL028 | AL028-3150 | DPW | 3.2.01 | HVAC and Refrigeration Systems | AHU-2 | Mechancial Room | 1 | AHU-2 | Trane | 4TEC3F60B1000AA | 10091LAE1v | ||
| C | AL028 | AL028-3150 | DPW | 3.2.01 | HVAC and Refrigeration Systems | AHU-3 | Mechancial Room | 1 | AHU-3 | Trane | CCDE10AENC | K83J03525 | ||
| C | AL028 | AL028-3150 | DPW | 3.2.01 | HVAC and Refrigeration Systems | AHU-4 | Mechancial Room | 1 | AHU-4 | Trane | ||||
| C | AL028 | AL028-ALL | DPW | 3.2.01.01 | HVAC Seasonal Start-Up and Shutdown | ALL | ||||||||
| C | AL028 | AL028-ALL | DPW | 3.2.01.02 | HVAC Water Treatment Services | ALL | ||||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 01 | 1 | EF 01 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | Unit Heater - 01 | Mechanical Room | 1 | Unit Heater - 01 | Trane | UHSA038S8AAAC | D83E01606 | ||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-01 | 1 | VAV-01 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-02 | 1 | VAV-02 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-03 | 1 | VAV-03 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-04 | 1 | VAV-04 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-05 | 1 | VAV-05 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-06 | 1 | VAV-06 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-07 | 1 | VAV-07 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-08 | 1 | VAV-08 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-09 | 1 | VAV-09 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-10 | 1 | VAV-10 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-11 | 1 | VAV-11 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-12 | 1 | VAV-12 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-13 | 1 | VAV-13 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-14 | 1 | VAV-14 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-15 | 1 | VAV-15 | ||||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | PUMP-02 | Mechanical Room | 1 | PUMP-02 | Taco | F1120GE360HIL | 588751V | ||
| C | AL028 | AL028-3150 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | PUMP 01 | 1 | PUMP 01 | Bell & Gosset | |||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.12 | Mini-splits and Window Units | CU-01 | 1 | CU-01 | Trane | 4A6C3060A30000BA | 9423J3R2F | |||
| C | AL028 | AL028-3150 | DPW | 3.2.01.12 | Mini-splits and Window Units | CTR-01 | 1 | CTR-01 | Carrier | 38CKC01832 | 3397E11599 | |||
| C | AL028 | AL028-3150 | DPW | 3.2.01.13 | HVAC Control System | CTR 02 | Mechanical Room | ALL | CTR 02 | Johnson Controls | ||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.13 | HVAC Control System | CTR 03 | Mechanical Room | 1 | CTR 03 | |||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.13 | HVAC Control System | CTR 04 - 09 | Mechanical Room | 6 | CTR 04 - 09 | |||||
| C | AL028 | AL028-3150 | DPW | 3.2.01.13 | HVAC Control System | CTR 10 - 12 | Mechanical Room | 3 | CTR 10 - 12 | |||||
| C | AL028 | AL028-3150 | DPW | 3.2.03 & 3.3.04 | Boilers and UPVs | BU 01 | 1 | BU 01 | Raypack (Rheem) | H3-0724 | 611257462 | |||
| C | AL028 | AL028-3150 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | IM01 | 1 | IM01 | Varies | |||||
| C | AL028 | AL028-3150 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | REF 02 | 1 | REF 02 | Victory | |||||
| C | AL028 | AL028-ALL | DPW | 3.2.10.01 | Drinking Fountains and Bottle Filling Stations | ALL | ||||||||
| C | AL028 | AL028-3150 | DPW | 3.2.10.02 | Water Heaters | WH 01 | Scullery 128 (Main Mech Rm) | 1 | WH 01 | Hatco | CC-15 | 53480-IL39 | ||
| C | AL028 | AL028-3150 | DPW | 3.2.10.02 | Water Heaters | WH-01 | Mechanical Room | 1 | WH-01 | A.O. Smith Water Heater | BTH 500A 104 | 1224M002075 | ||
| C | AL028 | AL028-ALL | DPW | 3.2.10.04 & 3.3.02 | Backflow Prevention Devices | All Building Interiors and All Exterior/Site | ALL | |||||||
| C | AL028 | AL028-ALL | DPW | 3.2.10.08 | Roof Drains/Gutters | All Buildings & Site | ALL | |||||||
| C | AL028 | AL028-ALL | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | All Buildings & Site | ALL | |||||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Pull Handles | Various Locations | 15 | ||||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 72 | ||||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Strobes/Flashing Alarms | Various Locations | 50 | ||||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | FACP | 1 | ||||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Notification | Various Locations | 8 | ||||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Mass Notification System | MNS Panel & System | ALL | S54301-Z76-A1 | |||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | FACP | 1 | FT2015-U3 | |||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 72 | SD 01 - 72 | OP921 | ||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Heat Sensors | Various Locations | 11 | SD 73 - 83 | OH921 | ||||
| C | AL028 | AL028-3150 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Fire Extinguishers | Various Locations | 32 | ||||||
| C | AL028 | AL028-ALL | DPW | 3.4.01 | Interior and Exterior Lighting Systems | All Buildings & Site | ALL | |||||||
| C | AL028 | AL028-3150 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | Wall Pack Outside | 16 | |||||||
| C | AL028 | AL028-3150 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | Photocell | 2 | |||||||
| C | AL028 | AL028-3150 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | Wall Pack Outside Storage Building | 8 | |||||||
| C | AL028 | AL028-3150 | DPW | 3.4.01.01 | Exterior Lighting Photocell and Time Clocks | Photo-01 | Room 115 | 2 | Photo-01 | |||||
| C | AL028 | AL028-3150 | DPW | 3.4.01.02 | Privately Owned Vehicle (POV) Parking Area Lights | POV Lights | 30 ft POV Pole Lights | 5 | POV Lights | Varies | Various Model Numbers | |||
| C | AL028 | AL028-3150 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | EMER-01 - 06 | 6 | EMER-01 - 06 | ||||||
| C | AL028 | AL028-3150 | DPW-FP | 3.4.01.05 | Emergency Exit Signs | EMER 09 - 23 | 15 | EMER 09 - 23 | ||||||
| C | AL028 | AL028-3150 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen Hood & Exhaust (Southbend oven/stove unit) | Kitchen/Roof | 1 | HOOD 01 | |||||
| C | AL028 | AL028-3150 | DES | 3.4.04 | Gates (Motorized and Manual) | GATE-01 | Electric gate operator (west) | 1 | GATE-01 | |||||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CH-1 | Room 142 (Outside) | 1 | CH-1 | Carrier | 30RAP0305J-0GF14 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | DOAS-1 | Room 8 - Per TAB Report | 1 | DOAS-1 | Addison | MCOA0240BA2A12BD00D000AK3B00A | 200503802001 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | MAU-1 | Outside Kitchen, Serves Kitchen 136 | 1 | MAU-1 | Carrier | 39MW Size 06W | Coil - 28MH / Filter - 31K2C0000000220253 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | HV-1 | Assembly 146 | 1 | HV-1 | Carrier | 39MN08W0275FJ11XDE | 2420U39540 Coil - 28MH / Filter - 31K2B0000000416253 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | HV-2 | Assembly 146 | 1 | HV-2 | Carrier | 39MN08W0275FJ11XDE | 2420U39543 Coil - 28MH / Filter - 31K2B0000000416253 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | HV-3 | Training 126 | 1 | HV-3 | Carrier | 39MN10W0275FL11XDE | 2520U39575 Coil - 28MH / Filter - 31K2B0000000416253 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | HV-4 | Training 126 | 1 | HV-4 | Carrier | 39MN10W0275FM11XDE | 2520U39567 Coil - 28MH/28ME / Filter - 31K2B0000000820243 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | AHU-1 | Mech Room 119 | 1 | AHU-1 | Carrier | 39MN25W0275FH16XCE | 2520U39600 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-1 | Mech Room | 1 | CU-1 | Carrier | 38APD0405J-28184 | |||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Siemens_TC | 1 | Siemens_TC | Siemens | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Siemens_ADXR | 1 | Siemens_ADXR | Siemens | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Siemens_QMX | 1 | Siemens_QMX | Siemens | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Viconics_FCUStat | Mechanical Room | 1 | Viconics_FCUStat | Viconics | ||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | BACnetRouter | 1 | BACnetRouter | BacnetRouter | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | FunctionalDevices_RIBTW24B-BCAI | 1 | FunctionalDevices_RIBTW24B-BCAI | ||||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | TPLink_Switch | 1 | TPLink_Switch | TPLink | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ACI_PS_Liquid | 1 | ACI_PS_Liquid | ACI | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ACI_PS_Liquid_Install | 1 | ACI_PS_Liquid_Install | ACI | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ACI_TS_Immersion | 1 | ACI_TS_Immersion | ACI | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ACI_TS_RH_OA | 1 | ACI_TS_RH_OA | ACI | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ACI_TS_Space | 1 | ACI_TS_Space | ACI | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ACI_TS_Thermowell | 1 | ACI_TS_Thermowell | ACI | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ControlPanels | DDC CONTROL PANEL | 1 | ControlPanels | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ControlPanels_Layout | DDC CONTROL PANEL | 1 | ControlPanels_Layout | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Saginaw_Panels | 1 | Saginaw_Panels | Saginaw | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | FunctionalDevices_RIBU1C | 1 | FunctionalDevices_RIBU1C | ||||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | FunctionalDevices_RIBXGTA | 1 | FunctionalDevices_RIBXGTA | ||||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | FunctionalDevices_TR40VA013 | 1 | FunctionalDevices_TR40VA013 | ||||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | FunctionalDevices_TR100VA004 | 1 | FunctionalDevices_TR100VA004 | ||||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | SurgeProtector | 1 | SurgeProtector | ||||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | DampersValves | 1 | DampersValves | ||||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Siemens_1-2inch | 1 | Siemens_1-2inch | Siemens | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Siemens_GQD | 1 | Siemens_GQD | Siemens | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Siemens_ConduitAdapter | 1 | Siemens_ConduitAdapter | Siemens | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Niagara_Supervisor | 1 | Niagara_Supervisor | Niagara | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | Niagara_Supervisor_OWS | 1 | Niagara_Supervisor_OWS | Niagara | |||||
| C | AL042 | AL042-ALL | DPW | 3.2.01.01 | HVAC Seasonal Start-Up and Shutdown | ALL | ||||||||
| C | AL042 | AL042-ALL | DPW | 3.2.01.02 | HVAC Water Treatment Services | ALL | ||||||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-1 | Roof Mounted | 1 | EF-1 | Greenheck | CUE-200HP-B-VGD-20-G | 16922682 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-2 | Roof Mounted | 1 | EF-2 | Greenheck | CUE-080-VG-X | 16920942 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-3 | Roof Mounted | 1 | EF-3 | Greenheck | CUE-101-VG | 16920965 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-4 | Roof Mounted | 1 | EF-4 | Greenheck | G-123-VG-X | 16920992 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-5 | Roof Mounted | 1 | EF-5 | Greenheck | G-070-VG-X | 16921002 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-6 | Roof Mounted | 1 | EF-6 | Greenheck | G-080-VG-X | 16921011 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | GV-1 | Roof Mounted-Gravity Ventilator | 1 | GV-1 | Greenheck | FGR-24x24 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | GV-2 | Roof Mounted-Gravity Ventilator | 1 | GV-2 | Greenheck | FGI-42x42 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | GV-3 | Roof Mounted-Gravity Ventilator | 1 | GV-3 | Greenheck | FGI-24x72 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | GV-4 | Roof Mounted-Gravity Ventilator | 1 | GV-4 | Greenheck | FGR-24x72 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | GV-5 | Roof Mounted-Gravity Ventilator | 1 | GV-5 | Greenheck | FGR-42x42 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | GV-6 | Roof Mounted-Gravity Ventilator | 1 | GV-6 | Greenheck | FGI-20x24 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-125-1 | Various | 1 | FCU-125-1 | Carrier | 42CGB08VRAYAAYCR | 918761-10-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-127-1 | Various | 1 | FCU-127-1 | Carrier | 42CGB06VLAYAAYCR | 918761-20-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-130-1 | Various | 1 | FCU-130-1 | Carrier | 42DEA14HLAYBAYER | 918761-30-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-130-2 | Various | 1 | FCU-130-2 | Carrier | 42DEA14HLAYBAYER | 918761-30-2 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-130-3 | Various | 1 | FCU-130-3 | Carrier | 42DEA14HLAYBAYER | 918761-30-3 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-131-1 | Various | 1 | FCU-131-1 | Carrier | 42CGB02FRAYAAYER | 918761-40-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-133-1 | Various | 1 | FCU-133-1 | Carrier | 42DEA08HLAYBAYER | 918761-50-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-133-2 | Various | 1 | FCU-133-2 | Carrier | 42DEA08HLAYBAYER | 918761-50-2 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-134-1 | Various | 1 | FCU-134-1 | Carrier | 42DEA10KLAYBAYER | 918761-60-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-134-2 | Various | 1 | FCU-134-2 | Carrier | 42DEA10KLAYBAYER | 918761-60-2 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-135-1 | Various | 1 | FCU-135-1 | Carrier | 42CGB02FLAYAAYER | 918761-70-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-136-1 | Various | 1 | FCU-136-1 | Carrier | 42CGB10DRAYAAYER | 91876-80-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | FCU-137-1 | Various | 1 | FCU-137-1 | Carrier | 42CGB08DRAYAAYER | 91876-90-1 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-1 | Storage 129 | 1 | UH-1 | |||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-2 | Storage 140 | 1 | UH-2 | |||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-3 | Storage 145 | 1 | UH-3 | |||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-4 | Storage 145 | 1 | UH-4 | |||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | CUH-1 | Cooridor 139 | 1 | CUH-1 | Carrier | 42CEA02VRAYBAYCR | |||
| C | AL042 | AL042-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-X | Wall mounted Heater | 1 | UH-X | Broan | ||||
| C | AL042 | AL042-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-01 | Modine Hanging Heater | 1 | UH-01 | Modine | HC 18SB01FA | |||
| C | AL042 | AL042-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-02 | Modine Hanging Heater | 1 | UH-02 | Modine | HC 18SB01FA | |||
| C | AL042 | AL042-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-03 | Modine Hanging Heater | 1 | UH-03 | Modine | HC 18SB01FA | |||
| C | AL042 | AL042-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-03 | Modine Hanging Heater | 1 | UH-03 | Modine | HC 18SB01FA | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-1 | Room 117 | 1 | VAV-1 | Carrier | 35E Single Duct Terminals | 35EN3020R160DXX000000H000W1200000.0P0000295008851475 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-2 | Room 113 | 1 | VAV-2 | Carrier | 35E Single Duct Terminals | 35EN3020R100DXX000000H000W1200000.0P0000102003060510 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-3 | Room 114 | 1 | VAV-3 | Carrier | 35E Single Duct Terminals | 35EN3020R120DXX000000H000W1200000.0P0000112503300560 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-4 | Room 106 | 1 | VAV-4 | Carrier | 35E Single Duct Terminals | 35EN3020R160DXX000000H000W1200000.0P0000238007151190 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-5 | Admin Area | 1 | VAV-5 | Carrier | 35E Single Duct Terminals | 35EN3020R120DXX000000H000W1200000.0P0000148004400740 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-6 | Lobby 102 | 1 | VAV-6 | Carrier | 35E Single Duct Terminals | 35EN3020R220DXX000000H000W1200000.0P0000377011301885 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.08 | Variable Air Volume (VAV) and Other Boxes | VAV-7 | Room 116 | 1 | VAV-7 | Carrier | 35E Single Duct Terminals | 35EN3020R090DXX000000H000W1200000.0P0000073502200400 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | Potable Hot Water Circulator | Water Heater Area | 1 | Potable Hot Water Circulator | |||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | Heating Water Circulator | Mechanical Room | 1 | Heating Water Circulator | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | HWP-1 | Circulation Pump | 1 | HWP-1 | Bell & Gossett | e-1510 2BD | Suction Diffuser EC-3X/EC-3Z | ||
| C | AL042 | AL042-00002 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | CHP-1 or CWP-1 | Circulation Pump | 1 | CHP-1 or CWP-1 | Bell & Gossett | e-1510 1.25AD-es | Suction Diffuser BA-3X/BA-3Z | ||
| C | AL042 | AL042-00002 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | AS-1 | Air Separator | 1 | AS-1 | Bell & Gossett | R-2-1/2N | 5360-25N-12-002 | ||
| C | AL042 | AL042-00002 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | AS-1 | Air Separator | 1 | AS-1 | Bell & Gossett | R-2-1/2N | 5360-25N-12-003 | ||
| C | AL042 | AL042-00002 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | ET-1 | Expansion Tank | 1 | ET-1 | Bell & Gossett | HFT-30V | |||
| C | AL042 | AL042-00002 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | ET-2 | Expansion Tank | 1 | ET-2 | Bell & Gossett | HFT-30V | |||
| C | AL042 | AL042-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-2 | Mini Split AC | 1 | AC-2 | Greenheck | ||||
| C | AL042 | AL042-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | CU-2 | Mini Split AC | 1 | CU-2 | Greenheck | ||||
| C | AL042 | AL042-00002 | DPW | 3.2.01.13 | HVAC Control System | DDC Control Panel | Mechanical Room | ALL | DDC Control Panel | DDC CONTROLS | ||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | MAU-1 - VFD Drive | Mechanical Room | 1 | MAU-1 - VFD Drive | ALACH550-UH-06A6-2 | ||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HV-1 - VFD Drive | Mechanical Room | 1 | HV-1 - VFD Drive | ALACH550-UH-012A-2 | ||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HV-2 - VFD Drive | Mechanical Room | 1 | HV-2 - VFD Drive | ALACH550-UH-012A-2 | ||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HV-3 - VFD Drive | Mechanical Room | 1 | HV-3 - VFD Drive | ALACH550-UH-012A-2 | ||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HV-4 - VFD Drive | Mechanical Room | 1 | HV-4 - VFD Drive | ALACH550-UH-012A-2 | ||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | AHU-1 - VFD Drive | Mechanical Room | 1 | AHU-1 - VFD Drive | ALACH550-UH-059A-2 | ||||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HVAC and DDC Components | Mechanical Room | 1 | HVAC and DDC Components | Siemens | P1C42ML125CBST | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | VFD Drive | Mechanical Room | 1 | VFD Drive | Siemens | 17DUC92BF | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HVAC and DDC Components | Mechanical Room | 1 | HVAC and DDC Components | Siemens | HNF362 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HVAC and DDC Components | Mechanical Room | 1 | HVAC and DDC Components | Siemens | HNF361 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HVAC and DDC Components | Mechanical Room | 1 | HVAC and DDC Components | Siemens | HNF361R | |||
| C | AL042 | AL042-00001 | DPW | 3.2.01.13 | HVAC Control System | HVAC and DDC Components | Mechanical Room | 1 | HVAC and DDC Components | Siemens | MMSKG1 | |||
| C | AL042 | AL042-00001 | DPW | 3.2.03 & 3.3.04 | Boilers and UPVs | B-1 | Boiler Room | 1 | B-1 | Lochinvar | FBN1501 | 2024 119647577 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.03 & 3.3.04 | Boilers and UPVs | SU 42 | 1 | SU 42 | ||||||
| C | AL042 | AL042-00001 | DPW | 3.2.03 & 3.3.04 | Boilers and UPVs | SU 62 | 1 | SU 62 | ||||||
| C | AL042 | AL042-00002 | DPW | 3.2.04 | Compressed Air Systems | OMS Shop | 1 | |||||||
| C | AL042 | AL042-00001 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | IM01 | 1 | IM01 | Varies | |||||
| C | AL042 | AL042-00001 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | REF 01 | 1 | REF 01 | Koch | |||||
| C | AL042 | AL042-00001 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | RIF 01 | 1 | RIF 01 | Koch | KSAF 1 | 561763C | |||
| C | AL042 | AL042-00001 | DPW | 3.2.10.01 | Drinking Fountains and Bottle Filling Stations | Drinking Fountains | Corridor 138 | 1 | Plumbing Fixtures | |||||
| C | AL042 | AL042-00002 | DPW | 3.2.10.01 | Drinking Fountains and Bottle Filling Stations | Drinking Fountains | Cooridor | 1 | Plumbing Fixtures | Elkay | ||||
| C | AL042 | AL042-00001 | DPW | 3.2.10.02 | Water Heaters | WH 01 | Boiler Room | 1 | WH 01 | Raypak | Raythern | 403218156 | ||
| C | AL042 | AL042-00001 | DPW | 3.2.10.02 | Water Heaters | WH 02 | Boiler Room | 1 | WH 02 | Raypak | RSS115-5 | RP0304G00733 | ||
| C | AL042 | AL042-00002 | DPW | 3.2.10.02 | Water Heaters | 10 GA. | Electric Water Heater | 1 | 10 GA. | Vista Therm Miser | 8VP10-1 | 493300400 | ||
| C | AL042 | AL042-ALL | DPW | 3.2.10.04 & 3.3.02 | Backflow Prevention Devices | All Building Interiors and All Exterior/Site | ALL | |||||||
| C | AL042 | AL042-00001 | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 400' | |||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 25 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Strobes/Flashing Alarms | Various Locations | 38 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | FACP | 2 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Notification | Various Locations | 6 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Mass Notification System | MNS Panel & System | ALL | S54301-Z76-A1 | |||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | FACP | 2 | FT2015-U3 | |||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 25 | SD 01 - 30 | OP921 | ||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Heat Sensors | Various Locations | 35 | SD 31 - 60 | OH921 | ||||
| C | AL042 | AL042-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Fire Extinguishers | Various Locations | 20 | ||||||
| C | AL042 | AL042-00002 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Fire Extinguishers | Various Locations | 20 | ||||||
| C | AL042 | AL042-ALL | DPW | 3.4.01 | Interior and Exterior Lighting Systems | All Buildings & Site | ALL | |||||||
| C | AL042 | AL042-00001 | DPW | 3.4.01.01 | Exterior Lighting Photocell and Time Clocks | Photo-01 | 1 | Photo-01 | ||||||
| C | AL042 | AL042-00001 | DPW | 3.4.01.02 | Privately Owned Vehicle (POV) Parking Area Lights | POV Lights | 24 ft POV Pole Lights | 6 | POV Lights | Varies | HID | |||
| C | AL042 | AL042-00001 | DES | 3.4.01.03 | Military Equipment Parking Lights | MEP Lights | Exterior | 6 | MEP Lights | Varies | Sq. steel & tapered aluminum-HID 250W (+/-) | |||
| C | AL042 | AL042-00001 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | EMER-01-12 & 17 | 12 | EMER-01-12 & 17 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | EMER-19-21 | 3 | EMER-19-21 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | Emergency Exit Lights | Various | 20 | Emergency Exit Lights | |||||
| C | AL042 | AL042-00001 | DPW-FP | 3.4.01.05 | Emergency Exit Signs | EMER 04 | 1 | EMER 04 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.4.01.05 | Emergency Exit Signs | EMER 13 - 15 | 4 | EMER 13 - 15 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.4.01.05 | Emergency Exit Signs | EMER 16 & 18 | 1 | EMER 16 & 18 | ||||||
| C | AL042 | AL042-00001 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen Hood & Exhaust (Wet) | Kitchen/Roof | 1 | HOOD 01 | Walter Kidde | Aqua Blue | |||
| C | AL042 | AL042-00001 | DES | 3.4.04 | Gates (Motorized and Manual) | GATE-01 | South end of complex | 1 | GATE-01 | Elite | ||||
| C | AL042 | AL042-00002 | DPW | 3.4.06 | Oil Water Separators | OWS | Exterior | 1 | OWS | Unknown | Unknown | |||
| C | AL042 | AL042-00002 | DPW | 3.4.07 | Overhead Doors | OD-01 | 16' Main shop | 1 | OD-01 | |||||
| C | AL042 | AL042-00002 | DPW | 3.4.07 | Overhead Doors | OD-02 | 16' Main shop | 1 | OD-02 | |||||
| C | AL042 | AL042-00002 | DPW | 3.4.07 | Overhead Doors | OD-03 | 16' Main shop | 1 | OD-03 | |||||
| C | AL042 | AL042-00002 | DPW | 3.4.07 | Overhead Doors | Steel Roll up Door 3'x3' | 1 | |||||||
| C | AL042 | AL042-00002 | DPW | 3.4.07 | Overhead Doors | Steel Roll up Door 8'x4' | 1 | |||||||
| C | AL042 | AL042-00001 | DPW | 3.4.11 | Interior Roll-up Doors | OD-01 | 1 | OD-01 | ||||||
| C | AL042 | AL042-00001 | DPW | 3.4.11 | Interior Roll-up Doors | OD-02 | 1 | OD-02 | ||||||
| C | AL042 | AL042-00001 | DPW | 3.4.11 | Interior Roll-up Doors | OD-03 | 1 | OD-03 | ||||||
| C | AL042 | AL042-00002 | DPW | 3.4.12 | Vehicle Exhaust Systems | VES-01 | MAINTENANCE SHOP | 1 | VES-01 | |||||
| C | AL042 | AL042-00001 | DPW | 3.4.15 | Wash Racks | WSHRK | 1 | N/A | WSHRK | Unknown | Unknown | |||
| C | AL042 | AL042-EXTERIOR | DPW | 3.4.15 | Wash Racks | WSHRK | Exterior | 1 | N/A | WSHRK | Unknown | Unknown | ||
| C | AL086 | AL086-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | IAH-01 | 1 | IAH-01 | Trane | TWE061D300AA | 16151NL3BA | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | OAC-01 | 1 | OAC-01 | Trane | 4TTA3048D3000CA | 16176X9B3F | |||
| C | AL086 | AL086-ALL | DPW | 3.2.01.01 | HVAC Seasonal Start-Up and Shutdown | ALL | ||||||||
| C | AL086 | AL086-ALL | DPW | 3.2.01.02 | HVAC Water Treatment Services | ALL | ||||||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 01 | 1 | EF 01 | ||||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | Battery Room | 1 | Battery Room | Exhaust Fan | GC785657 | H1308283470 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-3 | 1 | EF-3 | ||||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-2 | 1 | EF-2 | ||||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | Storage shed | 1 | Storage shed | Schaefer Exhaust Fan | |||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 01 - 04 | 4 | UH 01 - 04 | Beacon Morris | BT125A1NSA11 | L05G0331500 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 05 & 06 | 2 | UH 05 & 06 | ||||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 07 & 08 | 2 | UH 07 & 08 | Beacon Morris | |||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 09 & 10 | 2 | UH 09 & 10 | ||||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH-X | Supply Storage Rm | 1 | UH-X | TPI Corporation | FX0727TYP-48 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | HP-01 | 1 | HP-01 | Mitsubishi | MUZ-A09NA | 8001204T | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | HP-02 | 1 | HP-02 | Fujitsu | AOU 9RLFW | ||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | HP-03 | 1 | HP-03 | Gree | GWH24AC-D3DNA2D-0 | ||||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | HP-04 | 1 | HP-04 | Mitsubishi | MUZ-A09NA | 8000422T | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | HP-05 | 1 | HP-05 | Mitsubishi | MUZ-A09NA | 8004456T | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | HP-06 | 1 | HP-06 | Frigidaire | FR522PYC2 | IK25253706 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | HP-07 | 1 | HP-07 | Mitsubishi | MUZ-A17NA | 80001878T | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-07 | 1 | AC-07 | Mitsibishi | MSZ-A17NA | 8004453 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-02 | 1 | AC-02 | FUJITSU | ASU9RLF1 | MXA031502 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-00 | 1 | AC-00 | Mitsibishi | MSZ-AO9NA | 8008941 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-03 | 1 | AC-03 | GREE | AOU9RLFW1 | MXN004502 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-04 | 1 | AC-04 | Mitsibishi | MSZ-A09NA | 8008942 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.12 | Mini-splits and Window Units | Battery Room | 1 | Battery Room | Bard - AC UNIT | W18A2 | 313K133052894-02 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.01.13 | HVAC Control System | DDC Control Panel | Mechanical Room | ALL | DDC Control Panel | DDC CONTROLS | ||||
| C | AL086 | AL086-00002 | DPW | 3.2.04 | Compressed Air Systems | Comp-01 | 1 | Comp-01 | Ingersoll Rand | Grainger 247 | 902040128 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.04 | Compressed Air Systems | Comp-02 | 1 | Comp-02 | Ingersoll Rand | 2475N7.5 | 706210037 | |||
| C | AL086 | AL086-00002 | DPW | 3.2.04 | Compressed Air Systems | Comp-03 | 1 | Comp-03 | Ingersoll Rand | |||||
| C | AL086 | AL086-00002 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | REF 01 | 1 | REF 01 | Whirlpool | ER2CHMXPL04 | EW3112297 | |||
| C | AL086 | AL086-00002 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | Ice Machine IM-01 | 1 | Ice Machine IM-01 | Scotsman | CU1526SA-1A | 12071320015824 | |||
| C | AL086 | AL086-00002 | DIL | 3.2.09 & 3.3.01 | Weight Handling Equipment (WHE) | Overhead Crane | 1 | Overhead Crane | Lodestar 5 ton | MW | H-002ES | |||
| C | AL086 | AL086-00002 | DPW | 3.2.10.01 | Drinking Fountains and Bottle Filling Stations | ALL | ||||||||
| C | AL086 | AL086-00002 | DPW | 3.2.10.02 | Water Heaters | WH 01 | Mechanical Room | 1 | WH 01 | Bradford White | MI75S6BN | EC10369775 | ||
| C | AL086 | AL086-00002 | DPW | 3.2.10.02 | Water Heaters | WH 02 | New Shop | 1 | WH 02 | GE | ||||
| C | AL086 | AL086-ALL | DPW | 3.2.10.04 & 3.3.02 | Backflow Prevention Devices | All Building Interiors and All Exterior/Site | ALL | |||||||
| C | AL086 | AL086-ALL | DPW | 3.2.10.08 | Roof Drains/Gutters | ALL | ||||||||
| C | AL086 | AL086-00002 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Fire Extinguishers | Various Locations | 12 | ||||||
| C | AL086 | AL086-00002 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | AMSA BAY BUILDING | Various Locations | 50 | AMSA BAY BUILDING | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.01.01 | Exterior Lighting Photocell and Time Clocks | Photo-01 | West wall | 1 | Photo-01 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.01.01 | Exterior Lighting Photocell and Time Clocks | Photo-02 | West wall | 1 | Photo-02 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.01.01 | Exterior Lighting Photocell and Time Clocks | Photo-03 | North wall | 1 | Photo-03 | |||||
| C | AL086 | AL086-00002 | DES | 3.4.01.03 | Military Equipment Parking Lights | MEP Lights | Exterior | 7 | MEP Lights | Varies | 35ft wood pole - 250W HPS - TC and P Cell (est) | |||
| C | AL086 | AL086-ALL | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | ALL | ||||||||
| C | AL086 | AL086-ALL | DPW-FP | 3.2.01.05 | Emergency Exit Signs | ALL |
| C | AL086 | AL086-ALL | DES | 3.4.04 | Gates (Motorized and Manual) | ALL | |||||||
| C | AL086 | AL086-EXTERIOR | DPW | 3.4.06 | Oil Water Separators | OWS | OWS/Wash Rack in 81st RD database and noted during site visit | 2 | OWS | Unknown | Unknown | ||
| C | AL086 | AL086-00002 | DPW | 3.4.07 | Overhead Doors | OD-01 | 1 | OD-01 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.07 | Overhead Doors | OD-02 | 1 | OD-02 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.07 | Overhead Doors | OD-03 | 1 | OD-03 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.07 | Overhead Doors | OD-04 | 1 | OD-04 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.07 | Overhead Doors | OD-05 | 1 | OD-05 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.07 | Overhead Doors | OD-06 | 1 | OD-06 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.07 | Overhead Doors | OD-07 | 1 | OD-07 | |||||
| C | AL086 | AL086-00002 | DPW | 3.4.11 | Interior Roll-up Doors | OD-01 | Supply Room Counter | 1 | OD-01 | ||||
| C | AL086 | AL086-00002 | DPW | 3.4.12 | Vehicle Exhaust Systems | VES-01 | MAINTENANCE SHOP | 1 | VES-01 | Cook | 120CPS | 316SC50353-00/0003201 | |
| C | AL086 | AL086-00002 | DPW | 3.4.12 | Vehicle Exhaust Systems | VES-02 | MAINTENANCE SHOP | 1 | VES-02 | Cook | |||
| C | AL086 | AL086-00002 | DPW | 3.4.15 | Wash Racks | WSHRK | 1 | WSHRK | Unknown | Unknown | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-01 | 1 | CU-01 | Trane | TTA120E300AA | 14293WATYA | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-02 | 1 | CU-02 | Trane | 4TTA304203000CA | 143041LX3F | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-03 | 1 | CU-03 | Trane | 4TTA3042D3000CA | 143041JL3F | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-04 | 1 | CU-04 | Trane | 4TTA3048D3000CA | 1427157S3F | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-05 | 1 | CU-05 | Trane | 4TTA3036B3000AA | 14272BTK3F | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-06 | 1 | CU-06 | Trane | 4TTA3036B3000AA | 142641HM3F | ||
| C | KY051 | KY051-ALL | DPW | 3.2.01.01 | HVAC Seasonal Start-Up and Shutdown | ALL | |||||||
| C | KY051 | KY051-ALL | DPW | 3.2.01.02 | HVAC Water Treatment Services | ALL | |||||||
| C | KY051 | KY051-00001 | DPW | 3.2.01.03 | Furnaces | 1 | FUR-01 | Trane | TUD080C948H4 | N315JHS1G | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01.03 | Furnaces | 1 | FUR-02 | Trane | 4TXCB042BC3HCBA | 142961DR5G | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01.03 | Furnaces | 1 | FUR-03 | Trane | 4TXCC043C3HCBA | 1423UYN5G | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01.03 | Furnaces | 1 | FUR-04 | Trane | 4TXCD05BC3HCBA | 143025DS5G | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01.03 | Furnaces | 1 | FUR-05 | Trane | 4TXCB036BC3HCBA | 14306AYC5G | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01.03 | Furnaces | 1 | FUR-06 | Trane | 4TXCB036BC3HCBA | 14306AWD5G | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 04 | 1 | EF 04 | Captive Aire | A1-D-250-G10 | 001180SE56-48PK | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 01 - 03 | 3 | EF 01 - 03 | Cook | ACE90GL001 | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 01 | 1 | UH 01 | Trane | GHND003ADF10000 | A98M50026 | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 02 | 1 | UH 02 | Reznor | XL125 | AFC3186N600 | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 03 | 1 | UH 03 | Trane | GHND003ADF10000 | A98M50022 | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 04 | 1 | UH 04 | Trane | GHND003ADF10000 | A98M50024 | ||
| C | KY051 | KY051-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 01 | 1 | UH 01 | 10-10#; 3-20#; 1-15#; 1-20#; 1-6L K | ||||
| C | KY051 | KY051-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 02 | 1 | UH 02 | Reznor | ||||
| C | KY051 | KY051-00002 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 03 | 1 | UH 03 | Trane | ||||
| C | KY051 | KY051-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | MUA 01 | Captive Aire | A1-D-250-G10 | |||
| C | KY051 | KY051-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 01 | Trane | 4YCC3024B1064BA | 1432HT89H | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | PUMP 01 | 2 | PUMP 01 | Bell & Gossett | NBF-22 | 103252LF1J31 | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | PUMP 02 | 2 | PUMP 02 | Bell & Gossett | NBF-22 | 103252LF1J31 | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC 01 | 1 | AC 01 | Mitsubishi Condensor | PUY-A12NHA4 | 33U07622B | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC 02 | 1 | AC 02 | Mitsubishi AHU | PKA-A12HA4 | 45A12382C | ||
| C | KY051 | KY051-00001 | DPW | 3.2.01.13 | HVAC Control System | DDC Control Panel | Mechanical Room | ALL | DDC Control Panel | DDC CONTROLS | |||
| C | KY051 | KY051-00001 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | IM01 | 1 | IM01 | Varies | ||||
| C | KY051 | KY051-00001 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | REF 01 | 1 | REF 01 | US Refrigeration | UMT-48 | A94BA00017Z | ||
| C | KY051 | KY051-00001 | DPW | 3.2.10.01 | Drinking Fountains and Bottle Filling Stations | Drinking Fountains | Cooridor | 2 | Plumbing Fixtures | Elkay | |||
| C | KY051 | KY051-00001 | DPW | 3.2.10.01 | Drinking Fountains and Bottle Filling Stations | Drinking Fountains | Assembly 127 | 1 | Plumbing Fixtures | Oasis | |||
| C | KY051 | KY051-00001 | DPW | 3.2.10.02 | Water Heaters | WH 01 | Mechanical Room | 1 | WH 01 | State | AT-H3-DV-N | 141017399 | |
| C | KY051 | KY051-00001 | DPW | 3.2.10.02 | Water Heaters | WH 02 | Mechanical Room | 1 | WH 02 | State | AT-H3-DV-N | 141016278 | |
| C | KY051 | KY051-00002 | DPW | 3.2.10.02 | Water Heaters | Water Heater | 1 | Hatco | 3CS | 18570-12 | |||
| C | KY051 | KY051-00002 | DPW | 3.2.10.02 | Water Heaters | Water Heater | 1 | Hatco | CC15 | 18550FLL2 | |||
| C | KY051 | KY051-ALL | DPW | 3.2.10.04 & 3.3.02 | Backflow Prevention Devices | All Building Interiors and All Exterior/Site | ALL | ||||||
| C | KY051 | KY051-00001 | DPW | 3.2.10.04 & 3.3.02 | Backflow Prevention Devices | BP 01 | Mech Room, Fire Prot Room | 1 | BP-01 | Wilkins | 975XL2 | ||
| C | KY051 | KY051-00002 | DPW | 3.2.10.06 | Lift Station/Sump Pumps/Septic Systems | Sewage Ejector Pump | Storage Rm 108 | 1 | Swaby | 5200X | B2166 | ||
| C | KY051 | KY051-00002 | DPW | 3.2.10.06 | Lift Station/Sump Pumps/Septic Systems | Sewage Ejector Pump | Storage Rm 108 | 1 | Swaby | 5200X | B2167 | ||
| C | KY051 | KY051-00001 | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 400' | ||||||
| C | KY051 | KY051-00002 | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 60' | ||||||
| C | KY051 | KY051-00002 | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 200' | ||||||
| C | KY051 | KY051-00002 | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 18 | ||||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Pull Handles | Various Locations | 7 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 31 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Heat Sensors | Various Locations | 4 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Strobes/Flashing Alarms | Various Locations | 5 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | FACP | 2 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Notification | Various Locations | 1 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | Main Building | 1 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | Main entrance | 1 | Fire-lite | MS-4 | |||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 31 | SD 01 - 31 | ||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Fire Extinguishers | Various Locations | 20 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Fire Extinguishers | Various Locations | 20 | |||||
| C | KY051 | KY051-00001 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | INTERIOR | Various Locations | ALL | INTERIOR | ||||
| C | KY051 | KY051-00002 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | LED Wall Pack Lights | 6 | ||||||
| C | KY051 | KY051-00002 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | Accent Lights | 3 | ||||||
| C | KY051 | KY051-00002 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | LED Wall Pack Lights | 4 | ||||||
| C | KY051 | KY051-00002 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | Accent Lights | 1 | ||||||
| C | KY051 | KY051-00001 | DPW | 3.4.01.01 | Exterior Lighting Photocell and Time Clocks | Photo-01 | Mech room | 1 | Photo-01 | ||||
| C | KY051 | KY051-00001 | DPW | 3.4.01.01 | Exterior Lighting Photocell and Time Clocks | Photo-02 | Mech room | 1 | Photo-02 | ||||
| C | KY051 | KY051-00001 | DPW | 3.4.01.01 | Exterior Lighting Photocell and Time Clocks | Photo-03 | Mech room | 1 | Photo-03 | ||||
| C | KY051 | KY051-00001 | DPW | 3.4.01.02 | Privately Owned Vehicle (POV) Parking Area Lights | POV Lights | xx ft POV Pole Lights | 3 | POV Lights | Varies | LED Pole Lights | ||
| C | KY051 | KY051-00001 | DES | 3.4.01.03 | Military Equipment Parking Lights | MEP Lights | Exterior | 2 | MEP Lights | Varies | Wood pole - Halogen | ||
| C | KY051 | KY051-00002 | DES | 3.4.01.03 | Military Equipment Parking Lights | MEP Lights | Exterior | 2 | MEP Lights | Varies | Wood pole - Halogen | ||
| C | KY051 | KY051-00001 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | EMER 01 & 02 | 2 | EMER 01 & 02 | |||||
| C | KY051 | KY051-00001 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | Emergency Exit Lights | Various | 6 | Emergency Exit Lights | ||||
| C | KY051 | KY051-00001 | DPW-FP | 3.4.01.05 | Emergency Exit Signs | EMER 03 - 12 | 10 | EMER 03 - 12 | |||||
| C | KY051 | KY051-00001 | DPW | 3.4.02 | Grease Traps | GT-01 | 1 | GT-01 | PDI | JA4 | |||
| C | KY051 | KY051-00001 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen Hood & Exhaust | Kitchen/Roof | 1 | EF 05 | Cook | 09 ACWH 90WL50H | 062SF3849D-00/0004601 | |
| C | KY051 | KY051-00001 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen Hood & Exhaust (8' Ansul) | Kitchen/Roof | 1 | HOOD 01 | Cyclovent | |||
| C | KY051 | KY051-00001 | DES | 3.4.04 | Gates (Motorized and Manual) | GATE-01 | Main entrance | 1 | GATE-01 | ||||
| C | KY051 | KY051-00001 | DES | 3.4.04 | Gates (Motorized and Manual) | GATE-02 | Motor pool lot | 1 | GATE-02 | ||||
| C | KY051 | KY051-00001 | DPW | 3.4.07 | Overhead Doors | OD-01 | 1 | OD-01 | Lift-Monster | ||||
| C | KY051 | KY051-00002 | DPW | 3.4.07 | Overhead Doors | OD-01 | 1 | OD-01 | Lift-Monster | ||||
| C | KY051 | KY051-00001 | DPW | 3.4.11 | Interior Roll-up Doors | OD-01 | 1 | OD-01 | JG Wilson | 108509 | |||
| C | KY051 | KY051-00001 | DPW | 3.4.11 | Interior Roll-up Doors | OD-02 | 1 | OD-02 | JG Wilson | 8540 | |||
| C | KY061 | KY061-ALL | DPW | 3.2.01 | HVAC and Refrigeration Systems | ALL | |||||||
| C | KY061 | KY061-ALL | DPW | 3.2.01.01 | HVAC Seasonal Start-Up and Shutdown | ALL | |||||||
| C | KY061 | KY061-ALL | DPW | 3.2.01.02 | HVAC Water Treatment Services | ALL | |||||||
| C | KY061 | KY061-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 02 | 1 | EF 02 | COOK | 120 ACE 120C150 | 062SF13257-00/0002101 | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 03 | 1 | EF 03 | PVC-Penn Ventilator CO | AB-35 | |||
| C | KY061 | KY061-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 05 & 06 | 2 | EF 05 & 06 | PVC-Penn Ventilator CO | ||||
| C | KY061 | KY061-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF-01 | ROOF EXHAUST FAN | 1 | EF-01 | 120 ACE 120CL50 | 062SF18257-00/0000701 | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | MUA-1 | ROOF EXHAUST FAN | 1 | MUA-1 | CAPTIVE AIRE | A1-D.250-G10 | 00150S3E56-48PK | |
| C | KY061 | KY061-00001 | DPW | 3.2.01.05 | Fan Coils and Unit Heaters | UH 01 | 1 | UH 01 | Berko | HUH524S5KW | |||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 01 | Trane | YCD150F3H03AA | 113910158D | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 02 | Trane | YSC090E3RHA0F000 | 115011145L | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 03 | Trane | YSC060E3RHA1B000 | 114911165L | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 04 | Trane | YSC090E3RHA0F000 | 115011310L | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 05 | Trane | YSC060E3RHA1B000 | 115011917L | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 06 | Trane | YSC060E3RHA1B000 | 115011903L | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 07 | Trane | YSC090E3RHA0F000 | 114910043L | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 08 | Trane | YSC090E3RHA0F000 | 115010819L | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 09 | Trane | YSC060E3RHA1B000 | 115011889L | ||
| C | KY061 | KY061-OMSSH | DPW | 3.2.01.07 | Rooftop Units | Roof | 1 | RTU 01 | Trane | YSC090E3RHAQF | 115011320L | ||
| C | KY061 | KY061-00001 | DPW | 3.2.01.09 | HVAC Water Distribution Systems | System | Mechanical Room | 1 | System | Bell & Gossett | NBF-22 | 103252LF | |
| C | KY061 | KY061-00001 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-01 | MITSIBISHI MINI SPLIT CONDENSER | 1 | AC-01 | MITSIBISHI | PUY-A12NHA4 | PUY-A12NHA4R1 | |
| C | KY061 | KY061-00001 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-01 | MITSIBISHI MINI SPLIT AIR HANDLER | 1 | AC-01 | MITSIBISHI | PKA-A12HA4 | 3ZA09227A | |
| C | KY061 | KY061-00001 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-02 | MITSIBISHI MINI SPLIT CONDENSER | 1 | AC-02 | MITSIBISHI | PUY-A18NHA4 | PUY-A18NHA4R1 | |
| C | KY061 | KY061-00001 | DPW | 3.2.01.12 | Mini-splits and Window Units | AC-02 | MITSIBISHI MINI SPLIT AIR HANDLER | 1 | AC-02 | MITSIBISHI | PKA-A18HA4 | 34A09872C | |
| C | KY061 | KY061-00001 | DPW | 3.2.01.12 | Mini-splits and Window Units | Includes EVAP and Condenser | MITSIBISHI MINI SPLIT DIGITAL THERMOSTS | 2 | Includes EVAP and Condenser | ||||
| C | KY061 | KY061-00001 | DPW | 3.2.01.13 | HVAC Control System | DDC Control Panel | Mechanical Room | ALL | DDC Control Panel | DDC CONTROLS | |||
| C | KY061 | KY061-OMSSH | DPW | 3.2.01.13 | HVAC Control System | DDC Control Panel | Mechanical Room | ALL | DDC Control Panel | DDC CONTROLS | |||
| C | KY061 | KY061-00001 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | IM01 | 1 | IM01 | Varies | ||||
| C | KY061 | KY061-00001 | DIL | 3.2.07 & 3.3.07 | Refrigerators, Freezers, and Ice Machines | RIF 01 | 1 | RIF 01 | Commander | ||||
| C | KY061 | KY061-00001 | DPW | 3.2.10.01 | Drinking Fountains and Bottle Filling Stations | Drinking Fountains | Corr. 128, Alcove 158 | 1 | Plumbing Fixtures | Elkay | |||
| C | KY061 | KY061-00001 | DPW | 3.2.10.02 | Water Heaters | WH-01 | Mechanical - 123 In Nook | 1 | WH-01 | A.O. SMITH | AT-H3-DV-N | 141004207 | |
| C | KY061 | KY061-00001 | DPW | 3.2.10.02 | Water Heaters | WH-02 | Mechanical - 123 In Nook | 1 | WH-02 | A.O. SMITH | AT-H3-DV-N | 141010088 | |
| C | KY061 | KY061-00001 | DPW | 3.2.10.02 | Water Heaters | WH-03 | Mechanical - 123 In Nook | 1 | WH-03 | A.O. SMITH | AT-H3-DV-N | 141009511 | |
| C | KY061 | KY061-00001 | DPW | 3.2.10.02 | Water Heaters | Water Heater | 1 | HATCO | 3CS | 81243-57 | |||
| C | KY061 | KY061-ALL | DPW | 3.2.10.04 & 3.3.02 | Backflow Prevention Devices | Building Interior and Exterior/Site | ALL | ||||||
| C | KY061 | KY061-00001 | DPW | 3.2.10.04 & 3.3.02 | Backflow Prevention Devices | Potable Water System, Fire Protection System | Mech Room, Fire Prot Room | 3 | |||||
| C | KY061 | KY061-00001 | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 2000' | ||||||
| C | KY061 | KY061-00001 | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 150' | ||||||
| C | KY061 | KY061-OMSSH | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 488' | ||||||
| C | KY061 | KY061-OMSSH | DPW | 3.2.10.08 | Roof Drains/Gutters | Building Exterior | 200' | ||||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Pull Handles | Various Locations | 7 | |||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 13 | |||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Heat Sensors | Various Locations | 4 | |||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Strobes/Flashing Alarms | Various Locations | 6 | |||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | Various Locations | 1 | |||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Notification | Various Locations | 1 | |||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | Various Locations | 1 | |||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | Common admin - 148 | 1 | Fire-lite Honeywell | sensiscan-1000 | |||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 13 | SD 01 - 13 | ||||
| C | KY061 | KY061-00001 | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Fire Extinguishers | Various Locations | 15 | |||||
| C | KY061 | KY061-OMSSH | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Pull Handles | Various Locations | 1 | |||||
| C | KY061 | KY061-OMSSH | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 2 | |||||
| C | KY061 | KY061-OMSSH | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Heat Sensors | Various Locations | ALL | |||||
| C | KY061 | KY061-OMSSH | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Strobes/Flashing Alarms | Various Locations | 1 | |||||
| C | KY061 | KY061-OMSSH | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | FACP | FACP | 1 | |||||
| C | KY061 | KY061-OMSSH | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Notification | Various Locations | 1 | |||||
| C | KY061 | KY061-OMSSH | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Smoke Detectors | Various Locations | 2 | SD 01 - 02 | ||||
| C | KY061 | KY061-OMSSH | DPW-FP | 3.2.11, 3.3.05 & 3.3.06 | Fire Protection Systems | Fire Extinguishers | Various Locations | 15 | |||||
| C | KY061 | KY061 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | WALL PACK LIGHTS LED | 8 | ||||||
| C | KY061 | KY061 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | INTERIOR | Various Locations | ALL | INTERIOR | ||||
| C | KY061 | KY061 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | INTERIOR | Various Locations | ALL | INTERIOR | ||||
| C | KY061 | KY061 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | EXTERIOR LIGHTING | ACCENT LIGHTS ON BUILDING | 12 | EXTERIOR LIGHTING | ||||
| C | KY061 | KY061 | DPW | 3.4.01 | Interior and Exterior Lighting Systems | WALL PACK LIGHTS LED | 18 | ||||||
| C | KY061 | KY061 | DPW | 3.4.01.02 | Privately Owned Vehicle (POV) Parking Area Lights | POV Lights | ALL | ||||||
| C | KY061 | KY061-ALL | DES | 3.4.01.03 | Military Equipment Parking Lights | MEP Lights | ALL | ||||||
| C | KY061 | KY061 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | ACCENT LIGHTS ON BUILDING | 3 | ||||||
| C | KY061 | KY061-00001 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | EMER 01 - 04 | 4 | EMER 01 - 04 | |||||
| C | KY061 | KY061-00001 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | Emergency Exit Lights | Various | 7 | Emergency Exit Lights | ||||
| C | KY061 | KY061-00001 | DPW-FP | 3.4.01.04 | Emergency Light Wall Packs | Emergency Exit Lights | Various | 30 | Emergency Exit Lights | McPhilben | |||
| C | KY061 | KY061-00001 | DPW-FP | 3.4.01.05 | Emergency Exit Signs | EMER 05 - 22 | 17 | EMER 05 - 22 | |||||
| C | KY061 | KY061-00001 | DPW | 3.4.02 | Grease Traps | GT-01 | 1 | GT-01 | Zurn | ||||
| C | KY061 | KY061-00001 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen Hood & Exhaust | Kitchen/Roof | 1 | EF 04 | PVC-Penn Ventilator CO | AB-35 | ||
| C | KY061 | KY061-00001 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen & Exhaust (10' Dry) | Kitchen/Roof | 1 | HOOD 01 | Duo-Aire | cw-130m3 | 63233 | |
| C | KY061 | KY061-00001 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen Hood & Exhaust | Kitchen/Roof | 1 | KEF-02 | CAPTIVE AIRE | DU30HFA | 1863242-03212014 | |
| C | KY061 | KY061-00001 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen Hood & Exhaust | Kitchen/Roof | 1 | KEF-03 | CAPTIVE AIRE | DU30HFA | 1863242-03212014 | |
| C | KY061 | KY061-00001 | DPW-FP | 3.4.03 | Exhaust Hoods and Ducts | Kitchen Hood & Exhaust | Kitchen/Roof | 1 | KEF-01 | CAPTIVE AIRE | NCA16FA | 1863242-03212014 | |
| C | KY061 | KY061-00001 | DES | 3.4.04 | Gates (Motorized and Manual) | GATE-01 | Main entrance | 1 | GATE-01 | ||||
| C | KY061 | KY061-00001 | DES | 3.4.04 | Gates (Motorized and Manual) | GATE-02 | Main gate | 1 | GATE-02 | ||||
| C | KY061 | KY061-OMSSH | DES | 3.4.04 | Gates (Motorized and Manual) | GATE-01 | Entry gate | 1 | GATE-01 | ||||
| C | KY061 | KY061-OMSSH | DES | 3.4.04 | Gates (Motorized and Manual) | GATE-02 | Main gate | 1 | GATE-02 | ||||
| C | KY061 | KY061-00001 | DPW | 3.4.07 | Overhead Doors | OD-01 | 1 | OD-01 | America | ||||
| C | KY061 | KY061-00001 | DPW | 3.4.07 | Overhead Doors | OD-02 | 1 | OD-02 | America | ||||
| C | KY061 | KY061-OMSSH | DPW | 3.4.07 | Overhead Doors | OD-01 | 1 | OD-01 | |||||
| C | KY061 | KY061-OMSSH | DPW | 3.4.07 | Overhead Doors | OD-02 | 1 | OD-02 | |||||
| C | KY061 | KY061-00001 | DPW | 3.4.11 | Interior Roll-up Doors | OD-01 | 1 | OD-01 | |||||
| C | KY061 | KY061-00001 | DPW | 3.4.11 | Interior Roll-up Doors | OD-02 | 1 | OD-02 | |||||
| C | MS002 | MS002-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | AHU-01 | 1 | AHU-01 | Carrier | 39ED11 | 3784T 23573 | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | AHU-02 | 1 | AHU-02 | Carrier | FY4ANF036000AAAA | 4008A84691 | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | MAU-01 | 1 | MAU-01 | Reznor | RG350-8 | BEC66J8N02128 | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | ACC-01 | South side of the building | 1 | ACC-01 | Trane | CGAM030A2L02AXD2A1A1B1AXXA1D1AXXXXXXXBXA3A1D1XXLXX | U14E42620 | |
| C | MS002 | MS002-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-01 | 1 | CU-01 | Sanyo | CH0971 | 33371 | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | CU-02 | 1 | CU-02 | Carrier | 25HCB336A300 | 4308E01038 | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01 | HVAC and Refrigeration Systems | AHU-01 | Mechanical Room | 2 | AHU-01 | Trane | CSAA017UAL00 | K19D27965 | |
| C | MS002 | MS003-00002 | DPW | 3.2.01 | HVAC and Refrigeration Systems | HVAC 01 | 1 | HVAC 01 | Apogee | SYSTEM 600 | |||
| C | MS002 | MS002-ALL | DPW | 3.2.01.01 | HVAC Seasonal Start-Up and Shutdown | ALL | |||||||
| C | MS002 | MS002-ALL | DPW | 3.2.01.02 | HVAC Water Treatment Services | ALL | |||||||
| C | MS002 | MS002-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 01 | ROOF | 1 | EF 01 | Penn Ventilator | BB 531 | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 02 | ROOF | 1 | EF 02 | Penn Ventilator | FMX-36-B | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 03 & 04 | ROOF | 2 | EF 03 & 04 | Penn Ventilator | FMX-18-8 | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 05 | ROOF | 1 | EF 05 | Penn Ventilator | CB18 | ||
| C | MS002 | MS002-00001 | DPW | 3.2.01.04 | Exhaust and Transfer Fans | EF 06 | ROOF | 1 | EF 06 | Centri Master | PV135 | 04C723301 |
This is the start of the file's text. The full file is on GovTribe.