Informational_Quote_Request.docx.pdf
PDF 65 KB Posted
- Solicitation number
- Not on record
About this file
This document is an Informational Quote Request form for tower and shelter space to support NOAA Weather Radio broadcast operations. The form seeks detailed market information from tower owners about potential lease sites in Denison, IA and Yakima, WA, with specific queries regarding tower characteristics, mounting space, shelter availability, and associated rental considerations. Key details include requirements for 25-30 linear feet of antenna mounting space, climate-controlled shelter with 12-36 square feet of floor space, electrical connections, potential standby power, and other site-specific infrastructure needs. The government emphasizes this is a non-binding request to gather market information for negotiating succeeding leases necessary to maintain uninterrupted National Weather Radio broadcast service.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INFORMATIONAL QUOTE
TOWER & SHELTER SPACE
Important: This is a request for an informational quote. The quotations furnished are not formal offers.
This request does not commit or obligate the Government. The Government is currently broadcasting NOAA Weather Radio on a nearby tower and is seeking market information.
Owner / Tower Company name: ____________________________
Lessor address: __________________________________________
Tower site address: _______________________________________
Asset Number & Name: ___________________________________
Tower site elevation (AMSL): _____________
Tower height (AGL): _______________
Is the tower constructed? [ ] Yes [ ] No
Is there 25 linear feet to 30 linear feet mounting space at, near or above:
X feet above AGL for an antenna attachment? [ ] Yes [ ] No
FYI – assume the antenna specifications are as described on - https://swr-rf.com/wrx-8/
If mounting space is available, what is your asking rental rate?
Are there any escalations associated with the asking rate?
Is there available climate controlled [HVAC] shelter space with electrical connections?
[ ] Yes [ ] No
If yes, is climate controlled [HVAC] shelter space with electrical connections part of the rental consideration (asking rate)? [ ] Yes [ ] No
If so, is there at least 12 to 36 square feet of floor space? [ ] Yes [ ] No
Is electricity provided as part of the rental consideration (asking rate)? [ ] Yes [ ] No
Are maintenance costs (landscaping and site upkeep) part of the rental consideration (asking rate)?
[ ] Yes [ ] No
Is standby power provided as part of the rental consideration (asking rate)? [ ] Yes [ ] No
If standby power is not provided, is ground space available for a Government generator and fuel tank?
[ ] Yes [ ] No
Any Additional costs [i.e. structural analysis or application fee, required?]: