IFB-Courtroom-AV-Schedule-D-Final-4-25-17.pdf
PDF 7 MB Posted
- Attached to
- Courtroom A/V Systems
- Solicitation number
- MC050317
- Issued by
- Monroe County, Wisconsin
About this file
This is a detailed technical specification and symbol schedule document for the Monroe County Justice Center audiovisual systems project in Sparta, Wisconsin. The document serves as a comprehensive guide for contractors bidding on the furnishing and installation of audio-visual systems in three courtrooms at the new Monroe County Justice Center. The specifications include detailed symbol legends, connector types, mounting requirements, and plate configurations necessary for integrating sophisticated courtroom technology systems. The project encompasses multiple components including microphone systems (bench conference, desk, wireless, and lavalier types), loudspeaker installations with various mounting options, cameras with pan/tilt/zoom capabilities, display monitors, projection screens, recording equipment, video conferencing capabilities, and an extensive network infrastructure utilizing RJ45 connections and fiber optics. The document specifies exact connector types (XLR 3-pin through 7-pin, BNC, HDMI, DVI-I, USB, and others), cable labeling requirements, and detailed plate drawings for courtroom areas, evidence presentation carts, and supplementary zones. All dimensions are provided in millimeters with metric-to-English conversion references, and the document emphasizes that contractors must verify existing site conditions and review all floor plans and ceiling plans for exact equipment locations and quantities.
The specification document includes comprehensive functional requirements, noting that system components shown represent signal flow requirements only and may not reflect all necessary components for complete working systems. The document establishes that some equipment is designated as Client Furnished Equipment (CFE), Owner Furnished Contractor Installed (OFCI), or Owner Furnished Owner Installed (OFOI), requiring coordination between multiple contractors on the project. Push-button switches are specified as momentary-action with illumination features, and all visible connector plates are to be color-determined by the architect or client representative, with engraved text and graphics in high-contrast colors. The specification provides plate details across multiple configurations (ranging from 2-gang to 4-gang setups) and identifies silver-anodized and black-anodized finish options depending on location. The document was finalized on February 28, 2017, with drawings prepared by RJW/jds, and requires contractors to submit detailed plate drawings as part of their bid submittals for architect review prior to fabrication to avoid rejection.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IFB-Courtroom-AV-Specifications-Final-4-25-17.pdf | ||
| IFB-Courtroom-AV-Rack-4-25-17.pdf | ||
| IFB-Courtroom-AV-AIA-A107-2007.pdf | ||
| IFB-Courtroom-AV-4-25-17.pdf | ||
| IFB Courtroom AV Schedule B Final 4-25-17.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THESE NOTES APPLY TO THE SYMBOL SCHEDULES IN THIS PACKAGE.
ONLY REFER TO THOSE SYMBOLS ON THE SCHEDULES THAT ARE SPECIFICALLY
REFERENCED ON A FLOOR OR CEILING PLAN. SOME SYMBOLS MAY NOT APPEAR
ANYWHERE ON A FLOOR OR CEILING PLAN.
THE 'PROVIDED EMPTY CONDUIT' COLUMNS IN THE SYMBOL SCHEDULES REPRESENT
EMPTY CONDUIT THAT IS PROVIDED BY OTHERS AND IS SHOWN HERE FOR CONVENIENCE
ONLY. UNLESS OTHERWISE NOTED.
SYMBOL SCHEDULE NOTES
GENERAL DRAWING NOTES
THESE NOTES APPLY TO ALL DRAWINGS IN THIS PACKAGE INCLUDING PLANS, SCHEDULES,
FUNCTIONAL REQUIREMENTS AND DETAILS.
SEE SPECIFICATIONS SECTION AND EQUIPMENT LIST FOR ADDITIONAL INFORMATION.
FIELD VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO ORDERING EQUIPMENT.
SYSTEM COMPONENTS SHOWN ON THE DRAWINGS DO NOT NECESSARILY REPRESENT
ALL NECESSARY COMPONENTS FOR A COMPLETE WORKING SYSTEM. SEE
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
ALL DIMENSIONS AND MEASUREMENTS ARE IN MILLIMETERS UNLESS INDICATED
OTHERWISE.
METRIC TO ENGLISH CONVERSION: 25.4MM = 1"
THESE NOTES ONLY APPLY WHERE DETAILS OF PLATES ARE SHOWN.
FIELD VERIFY SIZE OF PLATE PRIOR TO FABRICATING AND PRINTING.
NOTE THAT SOME PLATES MAY BE PROVIDED BY OTHERS.
VISIBLE PLATES ARE TO BE OF A COLOR DETERMINED BY THE ARCHITECT OR BY THE
CLIENT'S REPRESENTATIVE. PLATES THAT ARE LOCATED OUT OF SITE (INSIDE FLOOR
BOXES, UNDER DESKS, ETC.) SHALL BE PLAIN STEEL UNLESS OTHERWISE DIRECTED.
TEXT AND GRAPHICS ON PLATES SHALL BE ENGRAVED AND FILLED IN A HIGH
CONTRASTING COLOR.
CONNECTORS SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY. ACTUAL CONNECTORS
MAY VARY. WHERE PLATES ARE SHOWN WITH CONNECTORS UNDER OTHER CONTRACTS,
COORDINATE WITH THOSE CONTRACTORS TO PROVIDE A FINISHED PRODUCT
EQUIVALENT TO THAT SHOWN HEREIN.
PUSH-BUTTON SWITCHES TO BE MOMENTARY ACTION, NOT LATCHING, AND SHALL BE
ILLUMINATED WHEN CONDITION OF BUTTON LABEL IS TRUE. LETTER AT UPPER LEFT HAND
OF BUTTON DENOTES COLOR OF LENS WHEN CONDITION OF BUTTON LABEL IS TRUE. (DO
NOT ENGRAVE OR PRINT TOGGLE FUNCTION ON PLATE.) W = WHITE; R = RED; G = GREEN;
B = BLUE; Y = YELLOW
FUNCTIONAL REQUIREMENTS NOTES
THESE NOTES ONLY APPLY TO THE 'FUNCTIONAL REQUIREMENTS' DRAWINGS IN THIS
PACKAGE.
FUNCTIONAL REQUIREMENTS DRAWINGS SHOW A TYPICAL WORKING SYSTEM. REFER TO
SPECIFICATIONS SECTION AND EQUIPMENT LISTS TO DETERMINE THE ACTUAL REQUIRED
COMPONENT EQUIPMENT.
FUNCTIONAL REQUIREMENTS DRAWINGS DO NOT REPRESENT EXACT SIGNAL TYPES OR
WIRING. THE EQUIPMENT PROVIDED WILL DETERMINE THE TYPES OF SIGNALS. IT IS UP
TO THE CONTRACTOR PRIOR TO BID TO ENSURE THAT EACH COMPONENT EQUIPMENT
HAS COMPATIBLE SIGNALS OR PROVIDE SIGNAL CONVERTERS AS REQUIRED.
FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE INDICATES NEW/RE-WIRE
EQUIPMENT OR WIRING UNDER THIS CONTRACT.
FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE INDICATES EXISTING
EQUIPMENT OR WIRING THAT IS TO BE REUSED UNDER THIS CONTRACT.
FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE AND/OR LABELED AS (CFE)
INDICATES COURT FURNISHED EQUIPMENT OR WIRING UNDER THIS CONTRACT.
FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE AND/OR LABELED AS AN
ENCLOSURE OR A GROUP OF EQUIPMENT OR WIRING.
FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE AND/OR LABELED AS
(FUTURE) INDICATES FUTURE EQUIPMENT OR WIRING NOT INCLUDED IN THIS CONTRACT.
PLATE DETAILS NOTES
INCH
2-1/2
3-1/2
MILLIMETER
INCH MILLIMETER
BUILDING TRADES CONDUIT SIZES
(CFE) CLIENT FURNISHED EQUIPMENT
(OFCI) OWNER FURNISHED CONTRACTOR
INSTALLED
(OFOI) OWNER FURNISHED OWNER
INSTALLED
(PIA) PUBLIC INTERNET ACCESS
1/2
3/4
1-1/4
1-1/2
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
28 FEB 2017
RJW/jds
TA001
NONE
CONNECTOR LEGEND
XLR, 3-PIN FEMALE
SYMBOL DESCRIPTION
PUSH
XLR3F
XLR3M
PUSH
XLR4F
XLR4M
PUSH
XLR5F
XLR5M
PUSH
XLR6F
XLR6M
PUSH
XLR7F
XLR7M
PUSH
XLR3F
PUSH
XLR3F
PUSH
XLR4F
PUSH
XLR5F
XLR, 3-PIN MALE
XLR, 4-PIN FEMALE
XLR, 4-PIN MALE
XLR, 5-PIN FEMALE
XLR, 5-PIN MALE
XLR, 6-PIN FEMALE
XLR, 6-PIN MALE
XLR, 7-PIN FEMALE
XLR, 7-PIN MALE
XLR 3-PIN-1/4" COMBO, FEMALE
XLR, 3-PIN FEMALE, MINI
XLR, 4-PIN FEMALE, MINI
SYMBOL SYMBOL
XLR, 5-PIN FEMALE, MINI
DESCRIPTION DESCRIPTION
LOCKING
1/4"
1/4"
1/4"
3.5mm
RCA
BNC
HD15F
HD15M
HDMI
DVI-I
LIECHTENSTEIN
SPEAKON
SPEAKON
S-VIDEO
SPEAKON, 4-POLE
SPEAKON, 8-POLE
1/4" TR PHONE, LOCKING
1/4" TR PHONE
1/4" TRS PHONE
3.5mm TRS
RCA
S-VIDEO, 4-PIN
BNC
15-PIN HD (VGA), FEMALE
HDMI - Only captive type jacks shall be used.
DVI
25-PIN DB, FEMALE
15-PIN HD (VGA), MALE
9-PIN DB, FEMALE
9-PIN DB, MALE
RJ45
RJ45, LOCKING (XLR STYLE)
FIBER (LC TYPE)
FIBER (ST TYPE)
PHOENIX
USB TYPE A
USB TYPE B
PUSH BUTTON, SQUARE
TOGGLE SWITCH
VOLUME CONTROL/ATTENUATOR
PUSH BUTTON, ROUND
DB25F
DB9F
DB9M
RJ45
RJ45
FIBER
FIBER
PHX
USB
USB
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
28 FEB 2017
RJW/jds
TA002
FLOOR PLAN & REFLECTED CEILING PLAN SYMBOL LEGEND
L O
U D
S P
E A
K E
R S
EQUIPMENT
RACK(S)
E Q
U I P
M E
N T
R O
O M
L I S
T E
N I N
G
A S
S I S
T A
N C
E
N D
A N
G U
A G
E
F
R O
N T
IR
EMITTER
S I G
N A
L
D I S
T R
I B
U T
I O
N
SYMBOL DESCRIPTION MOUNTING REQUIREMENTS
HOOK UP TO TELEPHONE LINES, MULTIMEDIA BACKBONE, ETC. FROM THIS LOCATION.
BBXX BACKBOARD DESIGNATION NUMBER
S
X
S
X
S
X
S
X
ACTIVATED
FLOOR BOX
WALL
PLATE
EQUIPMENT
BACKBOARD
TABLE
PLATE
MOUNTED AT HORIZONTAL SURFACE OF
CASEWORK/MILLWORK
SURFACE MOUNTED IN CAVITY, ON WALL OR
CEILING
PLATE W/
INDICATORS
LOUDSPEAKER
FIRE RESISTANT PLYWOOD (BY
OTHERS)
EQUIPMENT RACK (CASTERS WHERE REQUIRED)
FLUSH MOUNTED INSIDE WALL CAVITY
MOUNTED AT VERTICAL SURFACE OF
CASEWORK/MILLWORK
A AMPLIFIER/LOUDSPEAKER COMBINATION
B BRACKET MOUNT
D SURFACE MOUNT LOUDSPEAKER
E EXISTING LOUDSPEAKER TO BE REUSED
F FLUSH MOUNT LOUDSPEAKER
H PROVIDE WITH HEADPHONE CONNECTION
I INTEGRATED LOUDSPEAKER IN DISPLAY
M MASKING SOUND ON LOUDSPEAKER DURING SIDEBAR
P PAGING LOUDSPEAKER
S COURTROOM SOUND ON LOUDSPEAKER MUTED DURING SIDEBAR
T TAMPER-RESISTANT LOUDSPEAKER
V FAR AND VIDEO CONFERENCE SOUND ONLY
Z ZONE FOR MIX
(#) SEE PLATE DRAWINGS FOR SERVICE REQUIREMENTS AT EACH LOCATION
S I G
N A
L
C N
T R
L
(#) SEE PLATE DRAWINGS FOR SERVICE REQUIREMENTS AT EACH LOCATION
B BACKBOX
C UNDER CARPET CONNECTION POINT, UNDER CARPET WIRING, ADAPT CONNECTIONS AS NEEDED
E EXISTING J-BOX OR FLOORBOX
M MULTIPIN QUICK-RELEASE CONNECTOR
P POKE THROUGH STYLE WIRING DEVICE, ADAPT PLATES AND CONNECTIONS AS NEEDED
U PROVIDE WITH UMBILICALS AND/OR CABLE WHIPS ONLY
NOTES
BBXX
USE PROVIDED INFRASTRUCTURE
X ANY COMBINATION BELOW
INTERFACE
PANEL
POKE THRU
UMBILICAL WITH
CABLE-END
CONNECTORS
ANCHOR UMBILICAL UNDER ACCESS FLOOR
LEAVING LOOSE END CAPABLE OF REACHING
FURNITURE WHICH CAN BE MOVED TO IT'S
DESIGNATED LOCATIONS.
MOUNTED AT VERTICAL SURFACE OF
CASEWORK/MILLWORK
X
S
LOUDSPEAKER
LOUDSPEAKER
LOUDSPEAKER
LOUDSPEAKER
IR
EMITTER
MOUNTED AT WALL
MOUNTED AT CEILING
PLATE FLUSH AT HEIGHT SPECIFIED
INSTALL CONNECTORS INSIDE BOX
RACK MOUNT - FRONT AND/OR REAR
NEAR WORKING SURFACE OF FURNITURE
ABOVE/BELOW TABLE TOP IN SPECIAL HOUSING
INSTALL CONNECTORS INSIDE BOX - SPLIT
BETWEEN LOW-VOLTAGE PARTITIONS
DOUBLE-GANG PLATE FLUSH IN WALL
UNLESS OTHERWISE SPECIFIED
U
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
28 FEB 2017
RJW/jds
TA003
FLUSH IN COUNTER TOP OR IN STAND-ALONE
BACKBOX
D I S
P L
Y
M
O N
I T
O R
S
PROJECTION SCREEN
VIDEO/DATA PROJECTOR
U.S. MARSHAL'S CAMERA
VIDEO/DATA PROJECTOR
FLAT PANEL DISPLAY
C A
M E
R A
C O
V E
R A
G E
V I D
E O
P R
O J E
C T
I O
N
SURFACE MOUNTED INSIDE CAVITY
PROVIDED & INSTALLED BY U.S. MARSHAL
SURFACE MOUNTED ON WALL OR SOFFIT
ON PORTABLE CART (PROVIDE UMBILICAL)
POSITIONED INSIDE CAVITY
LOW VOLTAGE CONTROL WIRING ONLY
ON CEILING PIPE MOUNT
IN RECESSED CAVITY
BUILT-IN OR
FREE-STANDING
CONTROL DEVICES
CONTROL TOUCH SCREEN
FLAT PANEL DISPLAY
VIDEO IMAGE PRINTER
C O
N T
R O
L
D E
V I C
E S
D E
V I C
E S
V
PC
LAPTOP
PC
X
TP
SYMBOL
CFE OR LOCATION SHOWN (SHOWN PROVIDED)
CFE OR LOCATION SHOWN (SHOWN CFE)
WALL MOUNT BRACKET
DESKTOP MODEL
DESKTOP OR FLUSH MOUNTED
DESCRIPTION MOUNTING REQUIREMENTS
A ANNOTATION INPUT MONITOR
B BRACKET MOUNT
C CONTROL COMPUTER
D DUAL INPUT
E(#) EVIDENCE DISPLAY SHOWING
NEAR OR FAR END WITH
PUBLISHING ZONE NUMBER
F FLUSH MOUNT
H CELL DISPLAY MONITOR WITH
PROGRAM AUDIO
K KNUCKLE MOUNT
L LOCAL COMPUTER MONITOR
A CAMERA FOCUS ON ATTORNEY
B PROVIDE PHYSICAL VIEW BARRIER AS REQ'D SO THAT
NO SHOTS OF JURORS ARE POSSIBLE
J CAMERA FOCUS ON JUDGE
L CAMERA FOCUS ON LECTERN
W CAMERA FOCUS ON WITNESS
ADJUST STOPS UNDER THIS CONTRACT FOR BEST PICTURE
NOT IN THIS CONTRACT. SHOWN FOR INFORMATIONAL & COORDINATION PURPOSES
ONLY.
X ANY COMBINATION BELOW
ROUTE ALL WIRING BACK TO EQUIPMENT BACKBOARD THROUGH CONDUIT OF
PATHWAY PROVIDED
A ATTORNEY CONTROL
B BAILIFF CONTROL
C COUNTDOWN / CLOCK
D DEPUTY CONTROL
F FLUSH MOUNT
I INTERPRETER MAIN CONTROL
J JUDGE CONTROL
X ANY COMBINATION BELOW
X ANY COMBINATION BELOW
NOTES
M WITH SOUND MASKING
N NTSC BASEBAND
P POST MOUNT
Q QUEUING MONITOR
R RESTRICTED ANGLE OVERLAY
S WITH COURTROOM SOUND
T TOGGLE AT MAIN CONTROL PANEL TO
SHOW EVIDENCE OR PEOPLE CAMERAS
V VIDEO CONFERENCE REMOTE PEOPLE
ONLY
W WALL MOUNT
Y TV
X
X
X
X
X
SHELF BELOW CLERK/COURTROOM DEPUTY'S
DESK
PAN/TILT/ZOOM/FOCUS
CAMERA
PAN/TILT/ZOOM/FOCUS
CAMERA
L LAW CLERK
O OFE/CFE
P PRISONER INTERCOM
R COURT REPORTER CONTROL
S ROUTER CONTROL SWITCH
T TECHNICAL DIRECTOR
V VOLUME CONTROL
W WIRELESS
ON SLIDING STAND
X
FLAT PANEL DISPLAY
FLAT PANEL DISPLAY
FLAT PANEL DISPLAY
FLOOR PLAN & REFLECTED CEILING PLAN SYMBOL LEGEND
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
28 FEB 2017
RJW/jds
TA004
I C
R O
P H
O N
E S
WHERE FURNITURE IS MOBILE, PROVIDE MULTI-CABLE "UMBILICAL" FOR
CONNECTION TO FLOOR BOX OR WALL PLATE
PLUGS INTO MILLWORK JACK OR WALL PLATE
PERMANENTLY MOUNTED
MOVABLE BASE MICROPHONE
FIXED BASE MICROPHONE
PORTABLE
PORTABLE
SINGLE CART B
ADDITIONAL POSITIONS FOR
SINGLE CART A
ADDITIONAL POSITIONS FOR
NOTESDESCRIPTION MOUNTING REQUIREMENTSSYMBOL
INSIDE CEILING CAVITY
W I T
N E
S S
B
O X
PROVIDE CUSTOM MOUNTING ARM
TABLE TOP
DOCUMENT CAMERA
ALL MISCELLANEOUS PROCESSORS, SWITCHERS AND CONVERTERS TO BE
INSIDE OF CART. PROVIDE MULTI-CABLE "UMBILICALS" FOR CONNECTION FROM
CART "B" TO CART "A" AND FOR CONNECTION FROM CART "A" TO FLOOR BOX
OR WALL PLATE(S).
CAMERA TARGET AREA
ZOOM/FOCUS CAMERA
CART 'B'
P O
R T
A B
E
R G
U M
E N
T
P R
E S
E N
T A
T I O
N
C
A R
T S
OVERHEAD MICROPHONE
BOUNDARY MICROPHONE PORTABLE OR MOUNTED
CART
B
CART
B
M
M
CART
A
CART
B
X
A ARRAY TYPE
B BENCH CONFERENCE
C CEILING MOUNTED
D DIRECTIONAL
M MOVABLE
R RECESSED IN CASEWORK OR FURNITURE
S STAND MOUNTED
V MOUNTED ON VERTICAL SURFACE
W WIRELESS
HANGING/DROP-DOWN FROM CEILING. PROVIDE
HOLLOW THREADED LAMP BASE WIRING SLEEVE
WITH WASHERS AND NUT IN COLOR TO MATCH
CEILING.
T
WALL MOUNT VOLUME
CONTROL
COUNTDOWN TIMER
CLOCK
MOUNTED AT VERTICAL SURFACE OF
WALL/CASEWORK/MILLWORK
MOUNTED AT HORIZONTAL SURFACE OF
CASEWORK/MILLWORK
V
LAVALIER MICROPHONE
PROVIDE 3 METERS OF EXTENSION CABLE & A
HOOK FOR STOWAGE UNDER COUNTERTOP.
(#) SEE PLATE DRAWINGS FOR SERVICE REQUIREMENTS AT EACH LOCATION
CART 'A', CONTAINS
EVIDENCE PRESENTATION
TOOLS
B BRACKET MOUNTED
F FLUSH MOUNTED
P PARTIALLY RECESSED
S SURFACE MOUNTED
X ANY COMBINATION BELOW
X ANY COMBINATION BELOW
NONE
B BRACKET MOUNTED
C CEILING MOUNTED
D DESKTOP
F FLUSH IN CEILING
S SURFACE MOUNTED
X ANY COMBINATION BELOW
X
B
X
M
L
NOT
SHOWN
X
X
X
X
X
X
FLOOR PLAN & REFLECTED CEILING PLAN SYMBOL LEGEND
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
28 FEB 2017
RJW/jds
TA005
D
E
F
I
C
USER VERIFICATION CODE:
BASIC CABLE ID TO AVOID
DOCUMENTATION LOOKUP.
CABLE LABELING REQUIREMENTS
NOTE: PROVIDE AT ALL
LOCATIONS WHERE DAILY
USERS MAY INTERACT WITH
CONNECTIONS.
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
28 FEB 2017
RJW/jds
TA006
SEE FLOOR PLANS
FOR LOCATIONS
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
2-GANG
PUSH
XLR3F
BENCH CONF MIC
Black Anodized
COURTROOM AREA - PLATE #1
PUSH
XLR3F
DESK MIC
TA701
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
28 FEB 2017
RJW/jds
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
2-GANG
RJ45
RTT
RJ45
MONITOR
Black Anodized
COURTROOM AREA - PLATE #2
RJ45
AV LAN
TA702
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
2-GANG
3.5mm
AUDIO IN
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
PC INPUT
PUSH
XLR3F
DESK MIC
Black Anodized
COURTROOM AREA - PLATE #3
PUSH
XLR7F
INTERPRETER
TA703
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
RJ45
AV IN
RJ45
MONITOR
2-GANG
COURTROOM AREA - PLATE #4
Black Anodized
TA704
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
2-GANG
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
COURTROOM AREA - PLATE #5
Black Anodized
BNC
ANTENNA B
BNC
ANTENNA A
NOTE: Extend antennas and mount under bench area for best reception. Do not install antennas directly to plate connectors.
TA705
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
2-GANG
RJ45
AV WAP
COURTROOM AREA - PLATE #6
Black Anodized
RJ45
AV LAN
TA706
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
COURTROOM AREA - PLATE #7
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
Black Anodized
2-GANG
RJ45
RTT IN
XLR7M
TABLETOP
NOTE: Provide 7-pin connector to ensure proper user connectivity.
All pins may not be used depending on the preferred configuration.
3.5mm
PLAYBACK
TA707
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
2-GANG
RJ45
RECORD AUDIO
COURTROOM AREA - PLATE #8
Black Anodized
XLR5M
RECORD
AUDIO 3&4
RJ45
AV LAN
XLR5M
RECORD
AUDIO 1&2
TA708
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
L
HEADPHONE
AMP
R
PWR
OUT L
OUT R
L
LEVEL
R
HEADPHONE
CCW
DUAL 10K
AUDIO
TAPER HEADPHONE
VOLUME
AUX MIX OUT
AUX MIX OUT
AUX VOLUME
POWER
SUPPLY
ANGLED 3-GANG SURFACE MOUNT/DESKTOP BOX
PLATE #17
VCA
PWR
10V
CTRL
LINE
CCW
10K LINEAR
TAPER
BENCH CONFERENCE SWITCH
EXISTING
REPORTER'S
PERSONAL PC OR
LAPTOP
LINE INPUT
NOTE: Use 3.5mm tip/ring/sleeve jack with tip and ring bridged for monaural operation.
LINE OUT
EXISTING
REPORTER'S
PERSONAL BACKUP
RECORDER
LINE INPUT
PLAYBACK
LIVE/PRIVATE
NOTE: CONTRACTOR
SHALL INSTRUCT USERS
THAT DUAL RECORDERS
MUST BE SET FOR
MATCHING IMPEDANCE
ROCKER SWITCH
NOTE: PROVIDE 3.5MM
CONNECTOR ON REAR OF
HOUSING FOR REPORTER'S
PRIVATE RECORDER
PLAYBACK CONNECTION.
MOMENTARY
MECHANICAL
SWITCH/LATCHING
FUNCTION
SEE FLOOR PLANS
FOR LOCATIONS
3.5mm
3-GANG
3.5mm
AUX MIX OUT
RCA
AUX MIX OUT
3.5mm
HEADPHONE
AUX VOLUME HEADPHONE VOLUME
ON
BENCH CONFERENCE
LIVE / PRIVATE PLAYBACK
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
COURTROOM AREA - PLATE #17
Black Anodized
SWITCHED LAMP POWER
SWITCH
Out
TO/FROM
CONNECTION
PLATES
TA717
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
COURTROOM AREA - PLATE #23
AUDIO FEED
COURT
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
SILVER ANODIZED
2-GANG
XLR3M
BALANCED LINE 1
XLR3M
BALANCED LINE 2
XLR3M
BALANCED LINE 3
XLR3M
BALANCED LINE 4
TA723
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
COURTROOM AREA - PLATE #25
AUDIO FEED
COURT
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
SILVER ANODIZED
2-GANG
XLR3M
BALANCED LINE 5
XLR3M
BALANCED LINE 6
XLR3M
BALANCED LINE 7
XLR3M
BALANCED LINE 8
TA725
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
4-GANG
COURTROOM AREA - PLATE #44
SILVER ANODIZED
PUSH
XLR3F
TABLE MIC
PUSH
XLR3F
AUDIO INPUT
RJ45
AV IN
SEE FLOOR PLANS
FOR LOCATIONS
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
NOTE: Tabletop connections are also required with this plate. See specifications.
TA744
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
4-GANG
COURTROOM AREA - PLATE #48
SILVER ANODIZED
PUSH
XLR3F
TABLE MIC
PUSH
XLR3F
AUDIO INPUT
RJ45
AV IN
PUSH
XLR7F
INTERPRETER
SEE FLOOR PLANS
FOR LOCATIONS
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
NOTE: Tabletop connections are also required with this plate. See specifications.
TA748
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
COURTROOM AREA - PLATE #54
RJ45
SWITCHER IN
RJ45
LECTERN MON
RJ45
VTC MON /
CONTROL
RJ45
AV LAN
RJ45
VTC CAM /
CONTROL
4-GANG
SILVER ANODIZED
SEE FLOOR PLANS
FOR LOCATIONS
DRAWING NOTE:
THE CONTRACTOR SHALL SUBMIT PLATE
DRAWINGS AS PART OF SUBMITTALS AS
DEFINED WITHIN THE SPECIFICATION.
PLATES FABRICATED WITHOUT PRIOR
REVIEW MAY BE REJECTED.
RJ45
EVIDENCE CAM
CONTROL
P U
S H
X L R
F
MICS
NOTE: Provide short extension umbilical for
VTC cart connection so the lectern does not have to be moved to connect to VTC cart.
X L R
M
VTC AUDIO
TA754
NONE
DRAWN BY:
SCALE:
DATE:
PROJECT TITLE:
The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in
Specifications and Design Intent Floor and
Ceiling Plans for contract inclusions, quantities and locations.
Monroe County Justice Center
Sparta, Wisconsin
| Drawings.pdf |
| MCJC TA001.pdf |
| Sheets and Views |
| Layout |
| MCJC TA002 |
| Sheets and Views |
| Layout |
| MCJC TA003 |
| Sheets and Views |
| Layout |
| MCJC TA004 |
| Sheets and Views |
| Layout |
| MCJC TA005 |
| Sheets and Views |
| Layout |
| MCJC TA006 |
| Sheets and Views |
| Layout |
| MCJC TA100 |
| MCJC TA101a |
| MCJC TA101b |
| MCJC TA101c |
| MCJC TA101d |
| MCJC TA101e |
| MCJC TA101f |
| MCJC TA601 |
| MCJC TA602 |
| MCJC TA603 |
| MCJC TA701 |
| Sheets and Views |
| Layout |
| MCJC TA702 |
| Sheets and Views |
| Layout |
| MCJC TA703 |
| Sheets and Views |
| Layout |
| MCJC TA704 |
| Sheets and Views |
| Layout |
| MCJC TA705 |
| Sheets and Views |
| Layout |
| MCJC TA706 |
| Sheets and Views |
| Layout |
| MCJC TA707 |
| Sheets and Views |
| Layout |
| MCJC TA708 |
| Sheets and Views |
| Layout |
| MCJC TA717 |
| Sheets and Views |
| Layout |
| MCJC TA723 |
| Sheets and Views |
| Layout |
| MCJC TA725 |
| Sheets and Views |
| Layout |
| MCJC TA744 |
| Sheets and Views |
| Layout |
| MCJC TA748 |
| Sheets and Views |
| Layout |
| MCJC TA754 |
| Sheets and Views |
| Layout |
File details come from the government source that posted it. Updated .