This is a detailed technical specification and symbol schedule document for the Monroe County Justice Center audiovisual systems project in Sparta, Wisconsin. The document serves as a comprehensive guide for contractors bidding on the furnishing and installation of audio-visual systems in three courtrooms at the new Monroe County Justice Center. The specifications include detailed symbol legends, connector types, mounting requirements, and plate configurations necessary for integrating sophisticated courtroom technology systems. The project encompasses multiple components including microphone systems (bench conference, desk, wireless, and lavalier types), loudspeaker installations with various mounting options, cameras with pan/tilt/zoom capabilities, display monitors, projection screens, recording equipment, video conferencing capabilities, and an extensive network infrastructure utilizing RJ45 connections and fiber optics. The document specifies exact connector types (XLR 3-pin through 7-pin, BNC, HDMI, DVI-I, USB, and others), cable labeling requirements, and detailed plate drawings for courtroom areas, evidence presentation carts, and supplementary zones. All dimensions are provided in millimeters with metric-to-English conversion references, and the document emphasizes that contractors must verify existing site conditions and review all floor plans and ceiling plans for exact equipment locations and quantities.

The specification document includes comprehensive functional requirements, noting that system components shown represent signal flow requirements only and may not reflect all necessary components for complete working systems. The document establishes that some equipment is designated as Client Furnished Equipment (CFE), Owner Furnished Contractor Installed (OFCI), or Owner Furnished Owner Installed (OFOI), requiring coordination between multiple contractors on the project. Push-button switches are specified as momentary-action with illumination features, and all visible connector plates are to be color-determined by the architect or client representative, with engraved text and graphics in high-contrast colors. The specification provides plate details across multiple configurations (ranging from 2-gang to 4-gang setups) and identifies silver-anodized and black-anodized finish options depending on location. The document was finalized on February 28, 2017, with drawings prepared by RJW/jds, and requires contractors to submit detailed plate drawings as part of their bid submittals for architect review prior to fabrication to avoid rejection.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THESE NOTES APPLY TO THE SYMBOL SCHEDULES IN THIS PACKAGE.

ONLY REFER TO THOSE SYMBOLS ON THE SCHEDULES THAT ARE SPECIFICALLY

REFERENCED ON A FLOOR OR CEILING PLAN. SOME SYMBOLS MAY NOT APPEAR

ANYWHERE ON A FLOOR OR CEILING PLAN.

THE 'PROVIDED EMPTY CONDUIT' COLUMNS IN THE SYMBOL SCHEDULES REPRESENT

EMPTY CONDUIT THAT IS PROVIDED BY OTHERS AND IS SHOWN HERE FOR CONVENIENCE

ONLY. UNLESS OTHERWISE NOTED.

SYMBOL SCHEDULE NOTES

GENERAL DRAWING NOTES

THESE NOTES APPLY TO ALL DRAWINGS IN THIS PACKAGE INCLUDING PLANS, SCHEDULES,

FUNCTIONAL REQUIREMENTS AND DETAILS.

SEE SPECIFICATIONS SECTION AND EQUIPMENT LIST FOR ADDITIONAL INFORMATION.

FIELD VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO ORDERING EQUIPMENT.

SYSTEM COMPONENTS SHOWN ON THE DRAWINGS DO NOT NECESSARILY REPRESENT

ALL NECESSARY COMPONENTS FOR A COMPLETE WORKING SYSTEM. SEE

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

ALL DIMENSIONS AND MEASUREMENTS ARE IN MILLIMETERS UNLESS INDICATED

OTHERWISE.

METRIC TO ENGLISH CONVERSION: 25.4MM = 1"

THESE NOTES ONLY APPLY WHERE DETAILS OF PLATES ARE SHOWN.

FIELD VERIFY SIZE OF PLATE PRIOR TO FABRICATING AND PRINTING.

NOTE THAT SOME PLATES MAY BE PROVIDED BY OTHERS.

VISIBLE PLATES ARE TO BE OF A COLOR DETERMINED BY THE ARCHITECT OR BY THE

CLIENT'S REPRESENTATIVE. PLATES THAT ARE LOCATED OUT OF SITE (INSIDE FLOOR

BOXES, UNDER DESKS, ETC.) SHALL BE PLAIN STEEL UNLESS OTHERWISE DIRECTED.

TEXT AND GRAPHICS ON PLATES SHALL BE ENGRAVED AND FILLED IN A HIGH

CONTRASTING COLOR.

CONNECTORS SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY. ACTUAL CONNECTORS

MAY VARY. WHERE PLATES ARE SHOWN WITH CONNECTORS UNDER OTHER CONTRACTS,

COORDINATE WITH THOSE CONTRACTORS TO PROVIDE A FINISHED PRODUCT

EQUIVALENT TO THAT SHOWN HEREIN.

PUSH-BUTTON SWITCHES TO BE MOMENTARY ACTION, NOT LATCHING, AND SHALL BE

ILLUMINATED WHEN CONDITION OF BUTTON LABEL IS TRUE. LETTER AT UPPER LEFT HAND

OF BUTTON DENOTES COLOR OF LENS WHEN CONDITION OF BUTTON LABEL IS TRUE. (DO

NOT ENGRAVE OR PRINT TOGGLE FUNCTION ON PLATE.) W = WHITE; R = RED; G = GREEN;

B = BLUE; Y = YELLOW

FUNCTIONAL REQUIREMENTS NOTES

THESE NOTES ONLY APPLY TO THE 'FUNCTIONAL REQUIREMENTS' DRAWINGS IN THIS

PACKAGE.

FUNCTIONAL REQUIREMENTS DRAWINGS SHOW A TYPICAL WORKING SYSTEM. REFER TO

SPECIFICATIONS SECTION AND EQUIPMENT LISTS TO DETERMINE THE ACTUAL REQUIRED

COMPONENT EQUIPMENT.

FUNCTIONAL REQUIREMENTS DRAWINGS DO NOT REPRESENT EXACT SIGNAL TYPES OR

WIRING. THE EQUIPMENT PROVIDED WILL DETERMINE THE TYPES OF SIGNALS. IT IS UP

TO THE CONTRACTOR PRIOR TO BID TO ENSURE THAT EACH COMPONENT EQUIPMENT

HAS COMPATIBLE SIGNALS OR PROVIDE SIGNAL CONVERTERS AS REQUIRED.

FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE INDICATES NEW/RE-WIRE

EQUIPMENT OR WIRING UNDER THIS CONTRACT.

FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE INDICATES EXISTING

EQUIPMENT OR WIRING THAT IS TO BE REUSED UNDER THIS CONTRACT.

FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE AND/OR LABELED AS (CFE)

INDICATES COURT FURNISHED EQUIPMENT OR WIRING UNDER THIS CONTRACT.

FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE AND/OR LABELED AS AN

ENCLOSURE OR A GROUP OF EQUIPMENT OR WIRING.

FUNCTIONAL REQUIREMENTS DRAWINGS LINETYPE AND/OR LABELED AS

(FUTURE) INDICATES FUTURE EQUIPMENT OR WIRING NOT INCLUDED IN THIS CONTRACT.

PLATE DETAILS NOTES

INCH

2-1/2

3-1/2

MILLIMETER

INCH MILLIMETER

BUILDING TRADES CONDUIT SIZES

(CFE) CLIENT FURNISHED EQUIPMENT

(OFCI) OWNER FURNISHED CONTRACTOR

INSTALLED

(OFOI) OWNER FURNISHED OWNER

INSTALLED

(PIA) PUBLIC INTERNET ACCESS

1/2

3/4

1-1/4

1-1/2

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

28 FEB 2017

RJW/jds

TA001

NONE

CONNECTOR LEGEND

XLR, 3-PIN FEMALE

SYMBOL DESCRIPTION

PUSH

XLR3F

XLR3M

PUSH

XLR4F

XLR4M

PUSH

XLR5F

XLR5M

PUSH

XLR6F

XLR6M

PUSH

XLR7F

XLR7M

PUSH

XLR3F

PUSH

XLR3F

PUSH

XLR4F

PUSH

XLR5F

XLR, 3-PIN MALE

XLR, 4-PIN FEMALE

XLR, 4-PIN MALE

XLR, 5-PIN FEMALE

XLR, 5-PIN MALE

XLR, 6-PIN FEMALE

XLR, 6-PIN MALE

XLR, 7-PIN FEMALE

XLR, 7-PIN MALE

XLR 3-PIN-1/4" COMBO, FEMALE

XLR, 3-PIN FEMALE, MINI

XLR, 4-PIN FEMALE, MINI

SYMBOL SYMBOL

XLR, 5-PIN FEMALE, MINI

DESCRIPTION DESCRIPTION

LOCKING

1/4"

1/4"

1/4"

3.5mm

RCA

BNC

HD15F

HD15M

HDMI

DVI-I

LIECHTENSTEIN

SPEAKON

SPEAKON

S-VIDEO

SPEAKON, 4-POLE

SPEAKON, 8-POLE

1/4" TR PHONE, LOCKING

1/4" TR PHONE

1/4" TRS PHONE

3.5mm TRS

RCA

S-VIDEO, 4-PIN

BNC

15-PIN HD (VGA), FEMALE

HDMI - Only captive type jacks shall be used.

DVI

25-PIN DB, FEMALE

15-PIN HD (VGA), MALE

9-PIN DB, FEMALE

9-PIN DB, MALE

RJ45

RJ45, LOCKING (XLR STYLE)

FIBER (LC TYPE)

FIBER (ST TYPE)

PHOENIX

USB TYPE A

USB TYPE B

PUSH BUTTON, SQUARE

TOGGLE SWITCH

VOLUME CONTROL/ATTENUATOR

PUSH BUTTON, ROUND

DB25F

DB9F

DB9M

RJ45

RJ45

FIBER

FIBER

PHX

USB

USB

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

28 FEB 2017

RJW/jds

TA002

FLOOR PLAN & REFLECTED CEILING PLAN SYMBOL LEGEND

L O

U D

S P

E A

K E

R S

EQUIPMENT

RACK(S)

E Q

U I P

M E

N T

R O

O M

L I S

T E

N I N

G

A S

S I S

T A

N C

E

N D

A N

G U

A G

E

F

R O

N T

IR

EMITTER

S I G

N A

L

D I S

T R

I B

U T

I O

N

SYMBOL DESCRIPTION MOUNTING REQUIREMENTS

HOOK UP TO TELEPHONE LINES, MULTIMEDIA BACKBONE, ETC. FROM THIS LOCATION.

BBXX BACKBOARD DESIGNATION NUMBER

S

X

S

X

S

X

S

X

ACTIVATED

FLOOR BOX

WALL

PLATE

EQUIPMENT

BACKBOARD

TABLE

PLATE

MOUNTED AT HORIZONTAL SURFACE OF

CASEWORK/MILLWORK

SURFACE MOUNTED IN CAVITY, ON WALL OR

CEILING

PLATE W/

INDICATORS

LOUDSPEAKER

FIRE RESISTANT PLYWOOD (BY

OTHERS)

EQUIPMENT RACK (CASTERS WHERE REQUIRED)

FLUSH MOUNTED INSIDE WALL CAVITY

MOUNTED AT VERTICAL SURFACE OF

CASEWORK/MILLWORK

A AMPLIFIER/LOUDSPEAKER COMBINATION

B BRACKET MOUNT

D SURFACE MOUNT LOUDSPEAKER

E EXISTING LOUDSPEAKER TO BE REUSED

F FLUSH MOUNT LOUDSPEAKER

H PROVIDE WITH HEADPHONE CONNECTION

I INTEGRATED LOUDSPEAKER IN DISPLAY

M MASKING SOUND ON LOUDSPEAKER DURING SIDEBAR

P PAGING LOUDSPEAKER

S COURTROOM SOUND ON LOUDSPEAKER MUTED DURING SIDEBAR

T TAMPER-RESISTANT LOUDSPEAKER

V FAR AND VIDEO CONFERENCE SOUND ONLY

Z ZONE FOR MIX

(#) SEE PLATE DRAWINGS FOR SERVICE REQUIREMENTS AT EACH LOCATION

S I G

N A

L

C N

T R

L

(#) SEE PLATE DRAWINGS FOR SERVICE REQUIREMENTS AT EACH LOCATION

B BACKBOX

C UNDER CARPET CONNECTION POINT, UNDER CARPET WIRING, ADAPT CONNECTIONS AS NEEDED

E EXISTING J-BOX OR FLOORBOX

M MULTIPIN QUICK-RELEASE CONNECTOR

P POKE THROUGH STYLE WIRING DEVICE, ADAPT PLATES AND CONNECTIONS AS NEEDED

U PROVIDE WITH UMBILICALS AND/OR CABLE WHIPS ONLY

NOTES

BBXX

USE PROVIDED INFRASTRUCTURE

X ANY COMBINATION BELOW

INTERFACE

PANEL

POKE THRU

UMBILICAL WITH

CABLE-END

CONNECTORS

ANCHOR UMBILICAL UNDER ACCESS FLOOR

LEAVING LOOSE END CAPABLE OF REACHING

FURNITURE WHICH CAN BE MOVED TO IT'S

DESIGNATED LOCATIONS.

MOUNTED AT VERTICAL SURFACE OF

CASEWORK/MILLWORK

X

S

LOUDSPEAKER

LOUDSPEAKER

LOUDSPEAKER

LOUDSPEAKER

IR

EMITTER

MOUNTED AT WALL

MOUNTED AT CEILING

PLATE FLUSH AT HEIGHT SPECIFIED

INSTALL CONNECTORS INSIDE BOX

RACK MOUNT - FRONT AND/OR REAR

NEAR WORKING SURFACE OF FURNITURE

ABOVE/BELOW TABLE TOP IN SPECIAL HOUSING

INSTALL CONNECTORS INSIDE BOX - SPLIT

BETWEEN LOW-VOLTAGE PARTITIONS

DOUBLE-GANG PLATE FLUSH IN WALL

UNLESS OTHERWISE SPECIFIED

U

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

28 FEB 2017

RJW/jds

TA003

FLUSH IN COUNTER TOP OR IN STAND-ALONE

BACKBOX

D I S

P L

Y

M

O N

I T

O R

S

PROJECTION SCREEN

VIDEO/DATA PROJECTOR

U.S. MARSHAL'S CAMERA

VIDEO/DATA PROJECTOR

FLAT PANEL DISPLAY

C A

M E

R A

C O

V E

R A

G E

V I D

E O

P R

O J E

C T

I O

N

SURFACE MOUNTED INSIDE CAVITY

PROVIDED & INSTALLED BY U.S. MARSHAL

SURFACE MOUNTED ON WALL OR SOFFIT

ON PORTABLE CART (PROVIDE UMBILICAL)

POSITIONED INSIDE CAVITY

LOW VOLTAGE CONTROL WIRING ONLY

ON CEILING PIPE MOUNT

IN RECESSED CAVITY

BUILT-IN OR

FREE-STANDING

CONTROL DEVICES

CONTROL TOUCH SCREEN

FLAT PANEL DISPLAY

VIDEO IMAGE PRINTER

C O

N T

R O

L

D E

V I C

E S

D E

V I C

E S

V

PC

LAPTOP

PC

X

TP

SYMBOL

CFE OR LOCATION SHOWN (SHOWN PROVIDED)

CFE OR LOCATION SHOWN (SHOWN CFE)

WALL MOUNT BRACKET

DESKTOP MODEL

DESKTOP OR FLUSH MOUNTED

DESCRIPTION MOUNTING REQUIREMENTS

A ANNOTATION INPUT MONITOR

B BRACKET MOUNT

C CONTROL COMPUTER

D DUAL INPUT

E(#) EVIDENCE DISPLAY SHOWING

NEAR OR FAR END WITH

PUBLISHING ZONE NUMBER

F FLUSH MOUNT

H CELL DISPLAY MONITOR WITH

PROGRAM AUDIO

K KNUCKLE MOUNT

L LOCAL COMPUTER MONITOR

A CAMERA FOCUS ON ATTORNEY

B PROVIDE PHYSICAL VIEW BARRIER AS REQ'D SO THAT

NO SHOTS OF JURORS ARE POSSIBLE

J CAMERA FOCUS ON JUDGE

L CAMERA FOCUS ON LECTERN

W CAMERA FOCUS ON WITNESS

ADJUST STOPS UNDER THIS CONTRACT FOR BEST PICTURE

NOT IN THIS CONTRACT. SHOWN FOR INFORMATIONAL & COORDINATION PURPOSES

ONLY.

X ANY COMBINATION BELOW

ROUTE ALL WIRING BACK TO EQUIPMENT BACKBOARD THROUGH CONDUIT OF

PATHWAY PROVIDED

A ATTORNEY CONTROL

B BAILIFF CONTROL

C COUNTDOWN / CLOCK

D DEPUTY CONTROL

F FLUSH MOUNT

I INTERPRETER MAIN CONTROL

J JUDGE CONTROL

X ANY COMBINATION BELOW

X ANY COMBINATION BELOW

NOTES

M WITH SOUND MASKING

N NTSC BASEBAND

P POST MOUNT

Q QUEUING MONITOR

R RESTRICTED ANGLE OVERLAY

S WITH COURTROOM SOUND

T TOGGLE AT MAIN CONTROL PANEL TO

SHOW EVIDENCE OR PEOPLE CAMERAS

V VIDEO CONFERENCE REMOTE PEOPLE

ONLY

W WALL MOUNT

Y TV

X

X

X

X

X

SHELF BELOW CLERK/COURTROOM DEPUTY'S

DESK

PAN/TILT/ZOOM/FOCUS

CAMERA

PAN/TILT/ZOOM/FOCUS

CAMERA

L LAW CLERK

O OFE/CFE

P PRISONER INTERCOM

R COURT REPORTER CONTROL

S ROUTER CONTROL SWITCH

T TECHNICAL DIRECTOR

V VOLUME CONTROL

W WIRELESS

ON SLIDING STAND

X

FLAT PANEL DISPLAY

FLAT PANEL DISPLAY

FLAT PANEL DISPLAY

FLOOR PLAN & REFLECTED CEILING PLAN SYMBOL LEGEND

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

28 FEB 2017

RJW/jds

TA004

I C

R O

P H

O N

E S

WHERE FURNITURE IS MOBILE, PROVIDE MULTI-CABLE "UMBILICAL" FOR

CONNECTION TO FLOOR BOX OR WALL PLATE

PLUGS INTO MILLWORK JACK OR WALL PLATE

PERMANENTLY MOUNTED

MOVABLE BASE MICROPHONE

FIXED BASE MICROPHONE

PORTABLE

PORTABLE

SINGLE CART B

ADDITIONAL POSITIONS FOR

SINGLE CART A

ADDITIONAL POSITIONS FOR

NOTESDESCRIPTION MOUNTING REQUIREMENTSSYMBOL

INSIDE CEILING CAVITY

W I T

N E

S S

B

O X

PROVIDE CUSTOM MOUNTING ARM

TABLE TOP

DOCUMENT CAMERA

ALL MISCELLANEOUS PROCESSORS, SWITCHERS AND CONVERTERS TO BE

INSIDE OF CART. PROVIDE MULTI-CABLE "UMBILICALS" FOR CONNECTION FROM

CART "B" TO CART "A" AND FOR CONNECTION FROM CART "A" TO FLOOR BOX

OR WALL PLATE(S).

CAMERA TARGET AREA

ZOOM/FOCUS CAMERA

CART 'B'

P O

R T

A B

E

R G

U M

E N

T

P R

E S

E N

T A

T I O

N

C

A R

T S

OVERHEAD MICROPHONE

BOUNDARY MICROPHONE PORTABLE OR MOUNTED

CART

B

CART

B

M

M

CART

A

CART

B

X

A ARRAY TYPE

B BENCH CONFERENCE

C CEILING MOUNTED

D DIRECTIONAL

M MOVABLE

R RECESSED IN CASEWORK OR FURNITURE

S STAND MOUNTED

V MOUNTED ON VERTICAL SURFACE

W WIRELESS

HANGING/DROP-DOWN FROM CEILING. PROVIDE

HOLLOW THREADED LAMP BASE WIRING SLEEVE

WITH WASHERS AND NUT IN COLOR TO MATCH

CEILING.

T

WALL MOUNT VOLUME

CONTROL

COUNTDOWN TIMER

CLOCK

MOUNTED AT VERTICAL SURFACE OF

WALL/CASEWORK/MILLWORK

MOUNTED AT HORIZONTAL SURFACE OF

CASEWORK/MILLWORK

V

LAVALIER MICROPHONE

PROVIDE 3 METERS OF EXTENSION CABLE & A

HOOK FOR STOWAGE UNDER COUNTERTOP.

(#) SEE PLATE DRAWINGS FOR SERVICE REQUIREMENTS AT EACH LOCATION

CART 'A', CONTAINS

EVIDENCE PRESENTATION

TOOLS

B BRACKET MOUNTED

F FLUSH MOUNTED

P PARTIALLY RECESSED

S SURFACE MOUNTED

X ANY COMBINATION BELOW

X ANY COMBINATION BELOW

NONE

B BRACKET MOUNTED

C CEILING MOUNTED

D DESKTOP

F FLUSH IN CEILING

S SURFACE MOUNTED

X ANY COMBINATION BELOW

X

B

X

M

L

NOT

SHOWN

X

X

X

X

X

X

FLOOR PLAN & REFLECTED CEILING PLAN SYMBOL LEGEND

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

28 FEB 2017

RJW/jds

TA005

D

E

F

I

C

USER VERIFICATION CODE:

BASIC CABLE ID TO AVOID

DOCUMENTATION LOOKUP.

CABLE LABELING REQUIREMENTS

NOTE: PROVIDE AT ALL

LOCATIONS WHERE DAILY

USERS MAY INTERACT WITH

CONNECTIONS.

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

28 FEB 2017

RJW/jds

TA006

SEE FLOOR PLANS

FOR LOCATIONS

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

2-GANG

PUSH

XLR3F

BENCH CONF MIC

Black Anodized

COURTROOM AREA - PLATE #1

PUSH

XLR3F

DESK MIC

TA701

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

28 FEB 2017

RJW/jds

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

2-GANG

RJ45

RTT

RJ45

MONITOR

Black Anodized

COURTROOM AREA - PLATE #2

RJ45

AV LAN

TA702

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

2-GANG

3.5mm

AUDIO IN

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

PC INPUT

PUSH

XLR3F

DESK MIC

Black Anodized

COURTROOM AREA - PLATE #3

PUSH

XLR7F

INTERPRETER

TA703

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

RJ45

AV IN

RJ45

MONITOR

2-GANG

COURTROOM AREA - PLATE #4

Black Anodized

TA704

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

2-GANG

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

COURTROOM AREA - PLATE #5

Black Anodized

BNC

ANTENNA B

BNC

ANTENNA A

NOTE: Extend antennas and mount under bench area for best reception. Do not install antennas directly to plate connectors.

TA705

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

2-GANG

RJ45

AV WAP

COURTROOM AREA - PLATE #6

Black Anodized

RJ45

AV LAN

TA706

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

COURTROOM AREA - PLATE #7

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

Black Anodized

2-GANG

RJ45

RTT IN

XLR7M

TABLETOP

NOTE: Provide 7-pin connector to ensure proper user connectivity.

All pins may not be used depending on the preferred configuration.

3.5mm

PLAYBACK

TA707

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

2-GANG

RJ45

RECORD AUDIO

COURTROOM AREA - PLATE #8

Black Anodized

XLR5M

RECORD

AUDIO 3&4

RJ45

AV LAN

XLR5M

RECORD

AUDIO 1&2

TA708

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

L

HEADPHONE

AMP

R

PWR

OUT L

OUT R

L

LEVEL

R

HEADPHONE

CCW

DUAL 10K

AUDIO

TAPER HEADPHONE

VOLUME

AUX MIX OUT

AUX MIX OUT

AUX VOLUME

POWER

SUPPLY

ANGLED 3-GANG SURFACE MOUNT/DESKTOP BOX

PLATE #17

VCA

PWR

10V

CTRL

LINE

CCW

10K LINEAR

TAPER

BENCH CONFERENCE SWITCH

EXISTING

REPORTER'S

PERSONAL PC OR

LAPTOP

LINE INPUT

NOTE: Use 3.5mm tip/ring/sleeve jack with tip and ring bridged for monaural operation.

LINE OUT

EXISTING

REPORTER'S

PERSONAL BACKUP

RECORDER

LINE INPUT

PLAYBACK

LIVE/PRIVATE

NOTE: CONTRACTOR

SHALL INSTRUCT USERS

THAT DUAL RECORDERS

MUST BE SET FOR

MATCHING IMPEDANCE

ROCKER SWITCH

NOTE: PROVIDE 3.5MM

CONNECTOR ON REAR OF

HOUSING FOR REPORTER'S

PRIVATE RECORDER

PLAYBACK CONNECTION.

MOMENTARY

MECHANICAL

SWITCH/LATCHING

FUNCTION

SEE FLOOR PLANS

FOR LOCATIONS

3.5mm

3-GANG

3.5mm

AUX MIX OUT

RCA

AUX MIX OUT

3.5mm

HEADPHONE

AUX VOLUME HEADPHONE VOLUME

ON

BENCH CONFERENCE

LIVE / PRIVATE PLAYBACK

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

COURTROOM AREA - PLATE #17

Black Anodized

SWITCHED LAMP POWER

SWITCH

Out

TO/FROM

CONNECTION

PLATES

TA717

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

COURTROOM AREA - PLATE #23

AUDIO FEED

COURT

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

SILVER ANODIZED

2-GANG

XLR3M

BALANCED LINE 1

XLR3M

BALANCED LINE 2

XLR3M

BALANCED LINE 3

XLR3M

BALANCED LINE 4

TA723

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

COURTROOM AREA - PLATE #25

AUDIO FEED

COURT

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

SILVER ANODIZED

2-GANG

XLR3M

BALANCED LINE 5

XLR3M

BALANCED LINE 6

XLR3M

BALANCED LINE 7

XLR3M

BALANCED LINE 8

TA725

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

4-GANG

COURTROOM AREA - PLATE #44

SILVER ANODIZED

PUSH

XLR3F

TABLE MIC

PUSH

XLR3F

AUDIO INPUT

RJ45

AV IN

SEE FLOOR PLANS

FOR LOCATIONS

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

NOTE: Tabletop connections are also required with this plate. See specifications.

TA744

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

4-GANG

COURTROOM AREA - PLATE #48

SILVER ANODIZED

PUSH

XLR3F

TABLE MIC

PUSH

XLR3F

AUDIO INPUT

RJ45

AV IN

PUSH

XLR7F

INTERPRETER

SEE FLOOR PLANS

FOR LOCATIONS

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

NOTE: Tabletop connections are also required with this plate. See specifications.

TA748

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

COURTROOM AREA - PLATE #54

RJ45

SWITCHER IN

RJ45

LECTERN MON

RJ45

VTC MON /

CONTROL

RJ45

AV LAN

RJ45

VTC CAM /

CONTROL

4-GANG

SILVER ANODIZED

SEE FLOOR PLANS

FOR LOCATIONS

DRAWING NOTE:

THE CONTRACTOR SHALL SUBMIT PLATE

DRAWINGS AS PART OF SUBMITTALS AS

DEFINED WITHIN THE SPECIFICATION.

PLATES FABRICATED WITHOUT PRIOR

REVIEW MAY BE REJECTED.

RJ45

EVIDENCE CAM

CONTROL

P U

S H

X L R

F

MICS

NOTE: Provide short extension umbilical for

VTC cart connection so the lectern does not have to be moved to connect to VTC cart.

X L R

M

VTC AUDIO

TA754

NONE

DRAWN BY:

SCALE:

DATE:

PROJECT TITLE:

The items shown on this drawing are for signal flow requirements only. Items shown may not be required or are shown in partial quantities. Refer to equipment list in

Specifications and Design Intent Floor and

Ceiling Plans for contract inclusions, quantities and locations.

Monroe County Justice Center

Sparta, Wisconsin

Drawings.pdf
MCJC TA001.pdf
Sheets and Views
Layout
MCJC TA002
Sheets and Views
Layout
MCJC TA003
Sheets and Views
Layout
MCJC TA004
Sheets and Views
Layout
MCJC TA005
Sheets and Views
Layout
MCJC TA006
Sheets and Views
Layout
MCJC TA100
MCJC TA101a
MCJC TA101b
MCJC TA101c
MCJC TA101d
MCJC TA101e
MCJC TA101f
MCJC TA601
MCJC TA602
MCJC TA603
MCJC TA701
Sheets and Views
Layout
MCJC TA702
Sheets and Views
Layout
MCJC TA703
Sheets and Views
Layout
MCJC TA704
Sheets and Views
Layout
MCJC TA705
Sheets and Views
Layout
MCJC TA706
Sheets and Views
Layout
MCJC TA707
Sheets and Views
Layout
MCJC TA708
Sheets and Views
Layout
MCJC TA717
Sheets and Views
Layout
MCJC TA723
Sheets and Views
Layout
MCJC TA725
Sheets and Views
Layout
MCJC TA744
Sheets and Views
Layout
MCJC TA748
Sheets and Views
Layout
MCJC TA754
Sheets and Views
Layout

File details come from the government source that posted it. Updated .