IFB_26-010-HG_Attachment_A_-_Carver_Heights_Stormwater_Improvement_-_Drawings.pdf
PDF 4 MB Posted
- Attached to
- Carver Heights Stormwater Improvement Project
- Solicitation number
- IFB 26-010-HG
- Issued by
- Lake County, Florida
About this file
This is a final construction drawing set prepared by Dewberry Engineers Inc. for the City of Leesburg, Florida, documenting the Carver Heights Stormwater Improvements project located in Lake County. The drawings include a cover sheet, general notes, existing conditions and control map, overall grading plan, and cross-sectional details for four streets (Waitman Avenue, Johns Avenue, Talladega Street, and Georgia Avenue). The project scope encompasses construction of a dry percolation pond with six-foot chainlink fencing and a fourteen-foot swing gate, a swale at the rear of 816 Georgia Avenue, tree removal between 816 Georgia Avenue and 817 Talladega Street, relocation of existing electrical lines and light poles on City property, and encasement of a 2.5-inch gas main with six inches of concrete on all sides for ten feet. An additive alternate includes installation of sidewalks with Miami curb and gutter along the four named streets. The project is scheduled for completion within 90 calendar days from the Notice to Proceed, with liquidated damages of $904 per day assessed for delays. Specification questions must be submitted by February 16, 2026, with addenda issued by February 20, 2026, and bids due by March 4, 2026, followed by public bid opening via Zoom.
The drawings reference Florida Department of Transportation Standard Plans and Specifications (July 2023), applicable interim revisions, and FDEP standards for erosion control and NPDES permit compliance. All work must conform to existing utility locations and protections, including a 2.5-inch coated steel gas main, various PVC force mains, water lines, sanitary and storm sewers, and electrical utilities identified through field verification (VVH surveys). The contractor bears responsibility for geotechnical testing, site preparation, proof-rolling to achieve 98 percent compaction on footings, stormwater pollution prevention plan development, temporary and permanent erosion control measures, and restoration of disturbed landscaping and fencing. The drawings establish site benchmarks at elevations 71.01 feet and 72.98 feet (NAVD 1988) and detail grading sections showing 2 percent road grades, 4:1 maximum side slopes for fill areas, and specifications for sodding all slopes 5:1 or greater and seeding and mulching disturbed areas within seven days of construction completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
© 2025 Microsoft Corporation © 2025 TomTom
PREPARED FOR:
PROJECT
LOCATION
CITY OF LEESBURG
CARVER HEIGHTS STORMWATER IMPROVEMENTS
SOURCE: GOOGLE MAPS
SOURCE: GOOGLE MAPS
FINAL DRAWINGS
LEESBURG, FLORIDA
PREPARED BY:
VICINITY MAP
SITE LOCATION MAP
October 25
WAITMAN AVE
G
EO
R G
IA
A
VE
JOHNS AVE
TA
LL
AD
EG
A
ST
ERRORS AND OMISSIONS IN THESE CONSTRUCTION
DOCUMENTS SHALL IMMEDIATELY BE BROUGHT TO THE
ATTENTION OF THE ENGINEER FOR RESOLUTION.
GENERAL CONTRACTOR TO THOROUGHLY INSPECT
EXISTING CONDITIONS PRIOR TO SUBMITTING
BIDS.ANY DISCREPANCIES BETWEEN PLANS AND FIELD
CONDITIONS SHALL BE NOTED AT ONCE AND CALLED
TO THE ENGINEER'S ATTENTION PRIOR TO SUBMITTING
BIDS.
ALL CORRESPONDENCE IN REGARDS TO THESE
CONSTRUCTION / BID DOCUMENTS SHALL BE
DIRECTED TO JEFF PEQUEEN AND / OR ALBA MAS AT
DEWBERRY ENGINEERS INC.
GOVERNING STANDARD PLANS:
Florida Department of Transportation, FY2025-26 Standard plans for Road and Bridge Construction and applicable Interim Revisions (Irs).
Standard Plans for Road Construction and associated Irs are availalbe at the following website:
HTTP://www.fdot.gov/design/standardplans.shtm APPLICABLE IRs: IR536-001-01, IR521-001-01 Standard Plans for Bridge Construction are included in the Structures Plans Component.
GOVERNING STANDARD SPECIFICATIONS:
Florida Department of Transportation, July, 2023 Standard Specifications for Road and Bridge Construction at the following website:
HTTP://www.fdot.gov/programmanagement/implemented/specbooks
Sheet List Table Sheet Number Sheet Title
G-001 COVER SHEET
G-002 GENERAL NOTES
G-003 EXISTING CONDITIONS & CONTROL
C-001 OVERALL GRADING PLAN
C-002 WAITMAN AVE SECTIONS
C-003 JOHNS AVE SECTIONS
C-004 TALLADEGA ST SECTIONS (1)
C-005 TALLADEGA ST SECTIONS (2)
C-006 GEORGIA AVE SECTIONS (1)
C-006 GEORGIA AVE SECTIONS (2)
AutoCAD SHX Text CITY OF LEESBURG PUBLIC WORKS DEPARTMENT 501 W. MEADOW STREET LEESBURG, FL 34748 (352) 728-9786
AutoCAD SHX Text
800 N MAGNOLIA BLVD, 32803 ORLANDO, FLORIDA
AutoCAD SHX Text
JEFFERY D. PEQUEEN, P.E. FL P.E. NO. 47664
AutoCAD SHX Text Q:\City of Leesburg\Carver Heights Drainage TBD\CAD\dwg\50185663 Cover.dwg
OCTOBER 2025
GENERAL NOTES
G-002 X
GENERAL
PUBLIC RIGHTS-OF-WAY
UTILITIES
EROSION CONTROL
DEMOLITION AND CLEARING
PAVING, GRADING & DRAINAGE
CONTRACTOR RESPONSIBILITIES
FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (FDEP)
FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT)
AMERICANS WITH DISABILITIES ACT (ADA) BY U.S. DEPARTMENT OF JUSTICE
"MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" (MUTCD) PUBLISHED BY THE U.S. DEPARTMENT OF TRANSPORTATION, FEDERAL
HIGHWAY ADMINISTRATION
1. UNLESS OTHERWISE SPECIFIED, ALL CONSTRUCTION SHALL BE PERFORMED CONSISTENT WITH THE MOST RECENT PUBLICATION OF THE FOLLOWING CODES, STANDARDS AND SPECIFICATIONS AS WELL AS THE LATEST EDITIONS OF ALL OTHER APPLICABLE SPECIFICATIONS &
STANDARDS:
2. ALL CONSTRUCTION IS TO BE GOVERNED BY ALL APPLICABLE FEDERAL, STATE AND LOCAL LAWS, ORDINANCES, BUILDING AND SAFETY CODES.
3. IN THE EVENT THAT ANY STANDARDS OR SPECIFICATIONS AS DESCRIBED HEREIN ARE IN CONFLICT WITH EACH OTHER, OR THAT SHOWN IN THE PLANS, THE MORE STRINGENT CRITERIA WILL APPLY. CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD IMMEDIATELY AND IN WRITING SHOULD THE MORE STRINGENT CRITERIA BE UNCLEAR, FOR ENGINEER'S INTERPRETATION OF THE MORE STRINGENT CRITERIA TO BE USED.
7. GEOTECHNICAL RECOMMENDATIONS OR RECOMMENDATIONS AS PROVIDED IN SUPPLEMENTAL REPORTS BY OTHERS ARE NOT THE RESPONSIBILITY OF DEWBERRY INC., WHO HAS RELIED UPON THE REFERENCED GEOTECHNICAL REPORT(S) IN THE PREPARATION OF THE PLANS. ANY CONFLICT BETWEEN INFORMATION CONTAINED IN THE REPORT(S) AND THESE PLANS SHALL BE REPORTED TO THE ENGINEER AND OWNER IMMEDIATELY AND IN WRITING. DEWBERRY INC. ASSUMES NO RESPONSIBILITY FOR THE CORRECTNESS, COMPLETENESS, OR ACCURACY OF THE REPORT(S). WHEN THE PLANS AND/OR SPECIFICATIONS CONTAIN THE RESULTS OF A SOILS SURVEY, THE CONTRACTOR SHALL NOT ASSUME THE INFORMATION IS A GUARANTEE OF THE DEPTH, EXTENT OR CHARACTER OF MATERIAL PRESENT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MAKE A NECESSARY EXAMINATION OF THE SITE AND OF ANY MATERIAL SOURCES INDICATED ON
THE PLANS TO BE INFORMED OF THE CONDITIONS UNDER WHICH CONSTRUCTION IS TO OCCUR.
8. THE CONTRACTOR SHALL OBTAIN FROM THE OWNER COPIES OF PERMITS FOR ALL AGENCIES HAVING JURISDICTION, SUCH AS GOVERNMENTAL, REGULATORY OR LOCAL ENTITIES. THE CONTRACTOR SHALL BE EXPECTED TO REVIEW AND ABIDE BY ALL THE TERMS, CONDITIONS, REQUIREMENTS AND LIMITATIONS SET FORTH IN ALL OF THESE PERMITS. A COPY OF THE PERMITS SHALL BE KEPT ON THE
CONSTRUCTION SITE AND MADE AVAILABLE FOR REVIEW AT ALL TIMES.
9. THE STANDARDS AND SPECIFICATIONS AS LISTED HEREIN, THE GEOTECHNICAL REPORT(S), BOUNDARY AND TOPOGRAPHIC SURVEY(S), AND REQUIRED PERMITS ARE HEREBY INCORPORATED ALONG WITH THE PLANS BY DEWBERRY INC. AS THE COMPLETE "SITE CIVIL CONSTRUCTION
DOCUMENTS."
10. IF ITEMS APPEARING TO BE HISTORICAL OR ARCHEOLOGICAL ARTIFACTS ARE DISCOVERED AT ANY TIME DURING CONSTRUCTION WITHIN THE PROJECT LIMITS, IMMEDIATE NOTIFICATION SHALL BE PROVIDED TO THE OWNER, THE ENGINEER, AND THE BUREAU OF HISTORICAL PRESERVATION, DIVISION OF HISTORICAL RESOURCES R.A. GRAY BUILDING, 500 S. BRONOUGH ST. TALLAHASSEE, FLORIDA 32399-0250.
4. THESE PLANS WERE BASED ON THE BOUNDARY AND TOPOGRAPHIC SURVEY BY JONATHAN H GIBSON, PROFESSIONAL LAND SURVEYORS.
5. ALL ELEVATIONS SHOWN ON THESE DRAWINGS REFER TO NORTH GEODETIC VERTICAL DATUM OF 1988 (NAVD 88).
6. THESE PLANS WERE BASED ON THE GEOTECHNICAL REPORT(S) BY ANDREYEV ENGINEERING, INC., PROJECT NO. GPGT-25-061, RAYMOND W JONES, P.E./FL. REG NO. 58079, PHONE: 727-527-5735. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ACQUIRE A COPY OF THE REPORT(S) FROM THE GEOTECHNICAL ENGINEER, FAMILIARIZE THEMSELVES WITH THE CONDITIONS AS DESCRIBED IN THE REPORT(S), AND COMPLY WITH ALL RECOMMENDATIONS MADE IN THE REPORT(S) SPECIFICALLY FOR SOIL PREPARATION ON THE SITE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN A COPY ALL SUPPLEMENTAL REPORTS FOR THIS PROJECT FROM THE OWNER AND TO FOLLOW THE SUPPLEMENTAL REPORTS' RECOMMENDATIONS. THE GEOTECHNICAL ENGINEER IS RESPONSIBLE FOR ALL SUBSURFACE EXISTING CONDITIONS PERTAINING TO SOILS
AND GROUNDWATER.
CITY OF LEESBURG
ST JOHNS RIVER WATER MANAGEMENT DISTRICT (SJRWMD)
1. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE SITE, INCLUDING ALL SURFACE AND SUBSURFACE CONDITIONS, THE WORK REQUIRED AND ALL OTHER CONDITIONS THAT MAY EFFECT THE SUCCESSFUL COMPLETION OF THE JOB PRIOR TO COMMENCEMENT OF WORK.
2. THE LOCATION OF EXISTING UTILITY SERVICES, FACILITIES, AND STRUCTURAL FEATURES SHOWN ON THESE PLANS HAVE BEEN DETERMINED FROM THE BEST INFORMATION AND ARE PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OR THE COMPLETENESS OF THE LOCATION INFORMATION PROVIDED. ANY INACCURACY OR OMISSION IN SUCH INFORMATION SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO PROTECT THE EXISTING FEATURES FROM DAMAGE OR UNSCHEDULED INTERRUPTION OF SERVICE. SHOULD A DISCREPANCY ARISE BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS, WHICH WOULD APPRECIABLY AFFECT THE EXECUTION OF THESE PLANS, THE CONTRACTOR SHALL STOP ALL CONSTRUCTION AND NOTIFY THE ENGINEER
IMMEDIATELY.
3. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND PERMIT CONDITIONS BEARING ON THE CONDUCT OF THE WORK, AS DRAWN AND SPECIFIED. IF THE CONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT VARIANCE THEREWITH, HE SHALL PROMPTLY NOTIFY THE ENGINEER, IN WRITING, AND ANY NECESSARY CHANGES
SHALL BE ADJUSTED, AS PROVIDED IN THE AGREEMENT FOR CHANGES IN THE WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL LANDSCAPE BUFFERS, RETENTION AND DETENTION FACILITIES UNTIL THE PROJECT HAS BEEN ACCEPTED BY THE OWNER. ALL DISTURBED AREAS SHALL BE RETURNED TO EQUAL OR BETTER CONDITION.
5. THE CONTRACTOR SHALL BE RESPONSIBLE TO THE OWNER AND THE ENGINEER FOR THE ACTS AND OMISSIONS OF CONTRACTOR'S EMPLOYEES AND ALL HIS SUBCONTRACTORS AND THEIR AGENTS AND EMPLOYEES AND OTHER PERSONS PERFORMING ANY OF THE WORK
UNDER A CONTRACT WITH THE CONTRACTOR.
6. ALL WORK AND FURNISHED MATERIALS SHALL BE IN REASONABLE CONFORMITY WITH THE LINES, GRADES, GRADING SECTIONS, CROSS SECTIONS, DIMENSIONS, MATERIAL REQUIREMENTS AND TESTING REQUIREMENTS THAT ARE SPECIFIED IN THE CONTRACT, PLANS, DETAILS
OR SPECIFICATIONS.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAKING ALL NECESSARY ARRANGEMENTS WITH GOVERNMENTAL DEPARTMENTS, PUBLIC UTILITIES, PUBLIC CARRIERS, SERVICE COMPANIES, AND CORPORATIONS OWNING OR CONTROLLING ROADWAYS, RAILWAYS, WATER, SEWER, GAS, ELECTRICAL, TELEPHONE, AND TELEGRAPH FACILITIES SUCH AS PAVEMENTS, TRACKS, PIPING, WIRES, CABLES, CONDUITS, POLES, GUYS, OR OTHER SIMILAR FACILITIES, INCLUDING INCIDENTAL STRUCTURES CONNECTED THEREWITH THAT ARE ENCOUNTERED IN THE
WORK IN ORDER THAT SUCH ITEMS MAY BE PROPERLY SUPPORTED, PROTECTED OR LOCATED.
8. PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL FURNISH, ERECT AND MAINTAIN ALL BARRICADES, LIGHTS, WARNING SIGNS, AND PAVEMENT MARKINGS FOR HAZARDS AND THE CONTROL OF TRAFFIC THROUGH THE CONSTRUCTION ZONE IN CONFORMITY WITH THE ALL AGENCIES HAVING JURISDICTION STANDARDS TO EFFECTIVELY PREVENT ACCIDENTS AT ALL LOCATIONS WHERE CONSTRUCTION CAUSES AN OBSTRUCTION TO THE NORMAL FLOW OF TRAFFIC OR CREATES A HAZARD IN ANY WAY TO THE PUBLIC.
9. IN THE EVENT THE CONTRACTOR DISCOVERS ANY ERRORS OR OMISSIONS IN THE PLANS HE SHALL IMMEDIATELY NOTIFY THE OWNER OR
OWNER'S AGENT.
10. THE CONTRACTOR SHALL COMPLY WITH ALL LEGAL LOAD RESTRICTIONS IN THE HAULING OF MATERIALS ON PUBLIC ROADS BEYOND THE LIMITS OF THE WORK. A SPECIAL PERMIT WILL NOT RELIEVE THE CONTRACTOR OF LIABILITY FOR ANY DAMAGE THAT MAY RESULT FROM THE
MOVING OF MATERIALS AND EQUIPMENT.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SURVEY MONUMENTATION, SUCH AS THE PRESERVATION OF ALL PERMANENT REFERENCE MONUMENTS, PERMANENT CONTROL POINTS, PERMANENT BENCH MARKS, PROPERTY CORNERS, POINTS OR MARKERS. IN THE EVENT ANY MONUMENTATION IS DISTURBED, IT SHALL BE RESTORED BY A FLORIDA LICENSED SURVEYOR AND MAPPER
SELECTED BY THE OWNER AT THE CONTRACTOR'S EXPENSE.
12. THE OWNER, OWNER'S REPRESENTATIVES AND INSPECTORS OF APPLICABLE GOVERNMENT AGENCIES HAVING JURISDICTION, SHALL AT ALL TIMES HAVE ACCESS TO THE WORK SITE WHEREVER AND WHENEVER IT IS IN PREPARATION OR PROGRESS. THE CONTRACTOR SHALL
PROVIDE PROPER FACILITIES FOR SUCH ACCESS AND INSPECTIONS.
13. IT IS THE CONTRACTOR'S RESPONSIBILITY TO TAKE ALL REASONABLE AND PRUDENT PRECAUTIONS TO INSURE THAT ALL COMPLETED WORK, MATERIALS AND EQUIPMENT STORED ON SITE ARE SAFE AND SECURED FROM UNAUTHORIZED ACCESS OR USE. SUCH PRECAUTIONS
MAY INCLUDE INSTALLATION OF SIGNS, FENCES, OR POSTING OF SECURITY GUARDS.
14. CONTRACTOR SHALL, AT ALL TIMES, UTILIZE ALL NORMALLY ACCEPTED AND REASONABLY EXPECTED SAFETY PRACTICES AND COMPLY WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS, ORDINANCES AND GUIDELINES PERTAINING TO SAFE UTILIZATION OF EQUIPMENT OR
MATERIALS AS PUBLISHED BY MANUFACTURER.
15. ADEQUATE TRAFFIC CONTROL, SIGNAGE, BARRICADES AND FLAGMAN SERVICES SHALL BE FURNISHED AND MAINTAINED BY THE CONTRACTOR AT ALL POINTS WHERE CONSTRUCTION EQUIPMENT ENGAGED IN WORK ENTERS ONTO OR CROSSES FUNCTIONING
TRAFFIC-CARRYING ROADWAY.
16. THOSE PARTS OF WORK IN PLACE THAT ARE SUBJECT TO DAMAGE BECAUSE OF OPERATIONS BEING CARRIED ON ADJACENT THERETO SHALL BE COVERED, BOARDED UP OR SUBSTANTIALLY ENCLOSED WITH ADEQUATE PROTECTION BY THE CONTRACTOR AT CONTRACTOR'S
EXPENSE, PROTECTING WORK COMPLETED.
17. THE CONTRACTOR SHALL COMPLY IN EVERY RESPECT WITH THE FEDERAL OCCUPATIONAL HEALTH AND SAFETY ACT OF 1970 AND ALL RULES AND REGULATIONS NOW OR HEREAFTER IN EFFECT UNDER SAID ACT, AND THE CONTRACTOR FURTHER AGREES TO COMPLY WITH ANY AND ALL APPLICABLE STATE LAWS AND REGULATIONS PERTAINING TO JOB SAFETY AND HEALTH.
18. THE CONTRACTOR SHALL PROTECT AND KEEP OWNER (INCLUDING THEIR AGENTS AND EMPLOYEES) FREE AND HARMLESS FROM ANY AND ALL LIABILITY, PUBLIC OR PRIVATE, PENALTIES, CONTRACTUAL OR OTHERWISE, LOSSES, DAMAGES, COSTS, ATTORNEY'S FEES, EXPENSES, CAUSES OF ACTION, CLAIMS OR JUDGMENTS RESULTING FROM THE FEDERAL OCCUPATIONAL HEALTH AND SAFETY ACT OF 1970 AS AMENDED OR ANY RULE OR REGULATION PROMULGATED THEREUNDER OR OF ANY STATE LAWS OR REGULATIONS PERTAINING TO JOB SAFETY AND HEALTH ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE PERFORMANCE OF WORK OR WORK TO BE PERFORMED UNDER THIS CONTRACT, AND CONTRACTOR SHALL INDEMNIFY OWNER FROM ANY SUCH CLAIMS, PENALTIES, SUITS OR ACTIONS, PUBLIC OR PRIVATE, ADMINISTRATIVE OR JUDICIAL, INCLUDING ATTORNEY'S FEES PAID OR INCURRED BY OR ON BEHALF OF OWNER, JOINTLY OR SEVERALLY, AND/OR THEIR AGENTS AND EMPLOYEES. THE CONTRACTOR FURTHER AGREES, IN THE EVENT OF A CLAIMED VIOLATION OF ANY FEDERAL OR STATE SAFETY AND HEALTH LAW OR REGULATION ARISING OUT OF OR IN ANY WAY CONNECTED WITH THE PERFORMANCE OF WORK OR WORK TO BE PERFORMED UNDER THIS CONTRACT, OWNER MAY IMMEDIATELY TAKE WHATEVER ACTION IS DEEMED NECESSARY BY OWNER TO REMEDY THE CLAIMED VIOLATION. ANY AND ALL COSTS OR EXPENSES PAID OR INCURRED BY OWNER IN TAKING SUCH ACTION SHALL BE BORNE BY CONTRACTOR, AND CONTRACTOR AGREES TO PROTECT, HOLD HARMLESS AND INDEMNIFY OWNER AGAINST ANY AND
ALL SUCH COSTS OR EXPENSES.
19. THE CONTRACTOR SHALL TAKE ALL REASONABLE PRECAUTIONS FOR THE SAFETY OF, AND SHALL PROVIDE ALL REASONABLE PROTECTION
TO PREVENT DAMAGE, INJURY OR LOSS TO:
A. ALL EMPLOYEES ON THE WORK SITE AND ALL OTHER PERSONS WHO MAY BE AFFECTED THEREBY;
B. ALL THE WORK AND ALL MATERIALS AND EQUIPMENT TO BE INCORPORATED THEREIN, WHETHER IN STORAGE ON OR OFF THE SITE, UNDER
THE CARE, CUSTODY OR CONTROL OF THE CONTRACTOR OR ANY OF ITS SUBCONTRACTORS; AND
C. OTHER PROPERTY AT THE SITE OR ADJACENT THERETO, INCLUDING TREES, SHRUBS, LAWNS WALKS, PAVEMENTS, ROADWAY, STRUCTURES AND UTILITIES NOT DESIGNATED FOR DEMOLITION IN THE COURSE OF CONSTRUCTION.
20. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE SAFETY CODES AND WITH ALL APPLICABLE LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC, QUASI PUBLIC OR OTHER AUTHORITY HAVING JURISDICTION FOR THE SAFETY OF PERSONS OR PROPERTY OR FOR THEIR PROTECTION AGAINST DAMAGE, INJURY OR LOSS, OR DESIGNED TO PROTECT THE ENVIRONMENT.
THE CONTRACTOR SHALL ERECT AND MAINTAIN, AS REQUIRED BY EXISTING CONDITIONS AND PROGRESS OF THE WORK, ALL REASONABLE SAFEGUARDS FOR SAFETY AND PROTECTION, INCLUDING POSTING DANGER SIGNS AND OTHER WARNINGS AGAINST HAZARDS, PROMULGATING SAFETY REGULATIONS AND NOTIFYING OWNERS AND USERS OF ADJACENT UTILITIES OF THE EXISTENCE OF HAZARDS AND
OF THE SAFETY REGULATIONS.
21. ALL DAMAGE OR LOSS TO ANY PROPERTY REFERRED TO IN HEREIN CAUSED IN WHOLE OR IN PART BY THE CONTRACTOR, A SUBCONTRACTOR, OR BY ANYONE FOR WHOSE ACTS ANY OF THEM MAY BE LIABLE, SHALL BE REMEDIED BY THE CONTRACTOR, EXCEPT DAMAGE OR LOSS PROPERLY ATTRIBUTABLE SOLELY TO THE ACTS OR OMISSIONS OF THE OWNER, OR THE ENGINEER OR ANYONE EMPLOYED BY THEM, OR FOR WHOSE ACTS ANY OF THEM MAY BE LIABLE, AND NOT PROPERLY ATTRIBUTABLE IN WHOLE OR IN PART, TO THE
FAULT OR NEGLIGENCE OF THE CONTRACTOR.
22. UNTIL FINAL ACCEPTANCE OF THE WORK BY OWNER, THE CONTRACTOR SHALL HAVE THE CHARGE AND CARE OF AND SHALL BEAR THE RISK OF INJURY OR DAMAGE, LOSS OR EXPENSE TO ANY PART THEREOF, OR TO ANY MATERIALS STORED ON SITE, BY THE ACTION OF THE ELEMENTS OR FROM ANY OTHER CAUSE WHETHER ARISING FROM THE EXECUTION OR NON-EXECUTION OF THE WORK. THE CONTRACTOR SHALL REBUILD, REPAIR, RESTORE AND MAKE GOOD ALL INJURIES OR DAMAGES TO ANY PORTION OF THE WORK OCCASIONED BY ANY OF
THE ABOVE CAUSES BEFORE FINAL ACCEPTANCE AND SHALL BEAR THE EXPENSES THEREOF.
23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEETING ALL INSPECTION CRITERIA AND SCHEDULES, AND SIGNING FOR SAID INSPECTIONS.
24. THE CONTRACTOR SHALL CONTROL AND BE RESPONSIBLE FOR THEIR OPERATIONS AND THOSE OF THEIR SUBCONTRACTORS AND ALL SUPPLIERS, TO ASSURE THE LEAST INCONVENIENCE TO THE PUBLIC. THE CONTRACTOR SHALL MAINTAIN FREE AND UNOBSTRUCTED MOVEMENT OF VEHICULAR TRAFFIC AND SHALL LIMIT THEIR OPERATIONS IN RELATION TO THE SAFETY AND CONVENIENCE OF THE TRAVELING PUBLIC. UNDER ALL CIRCUMSTANCES, SAFETY SHALL BE THE MOST IMPORTANT CONSIDERATION.
25. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE POLICIES AND GUIDELINES ESTABLISHED BY ALL AGENCIES HAVING JURISDICTION FOR THE PRESERVATION OF ALL PUBLIC AND PRIVATE PROPERTY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE OR INJURY TO PROPERTY OF ANY CHARACTER, DURING THE EXECUTION OF THE WORK, RESULTING FROM ANY ACT, OMISSION, NEGLECT, OR MISCONDUCT IN THEIR MANNER OR METHOD OF EXECUTING THE WORK, OR AT ANYTIME DUE TO DEFECTIVE WORK OR MATERIALS.
26. THE CONTRACTOR SHALL NOT EXCAVATE, REMOVE, OR OTHERWISE DISTURB ANY MATERIAL, STRUCTURE OR PART OF A STRUCTURE WHICH IS LOCATED OUTSIDE THE LINES, GRADES OR GRADING SECTIONS ESTABLISHED FOR THIS PROJECT, EXCEPT WHERE SUCH EXCAVATION OR
REMOVAL IS PROVIDED FOR IN THE CONTRACT, PLANS OR SPECIFICATIONS.
27. THE CONTRACTOR SHOULD VERIFY THE QUANTITIES AND LENGTHS OF MATERIALS SHOWN ON THE PLANS. ANY DISCREPANCY BETWEEN MATERIAL CALLOUTS AND ACTUAL SHOWN IN PLAN VIEW IS TO BE BROUGHT TO THE ENGINEER'S ATTENTION BY THE CONTRACTOR PRIOR TO
BIDDING. IT IS THE ENGINEER'S INTENTION TO CONSTRUCT WHAT IS SHOWN ON THE PLANS.
28. ANY DISCREPANCY BETWEEN THE DIMENSIONS AND MEASUREMENTS SHOWN ON THE PLANS AND THE ACTUAL FIELD CONDITIONS SHALL IMMEDIATELY BE BROUGHT TO THE ENGINEER'S ATTENTION. FAILURE TO DO SO AND TO CONTINUE CONSTRUCTION SHALL MAKE THE CONTRACTOR RESPONSIBLE FOR ALL ERRORS AND NECESSARY CORRECTIONS THAT MAY SUBSEQUENTLY ARISE.
1. THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE AND LOCAL LAWS AND ALL REGULATIONS CONTROLLING POLLUTION OF THE
ENVIRONMENT.
2. THE CONTRACTOR SHALL DEVELOP AND IMPLEMENT A STORMWATER POLLUTION PREVENTION PLAN (SWPPP) ACCORDING TO EPA/FDEP NPDES CRITERIA TO MINIMIZE EROSION AND INSURE PROPER FUNCTIONING OF STORM WATER MANAGEMENT SYSTEM UPON COMPLETION OF CONSTRUCTION. IN ADDITION TO MEETING EPA/FDEP NPDES CRITERIA, THE SWPPP SHALL BE SUBMITTED TO AND COMPLY WITH LOCAL AGENCY (CITY OF LEESBURG) HAVING JURISDICTION'S MINIMUM EROSION CONTROL CRITERIA.
3. CONTRACTOR SHALL EXECUTE ALL MEASURES NECESSARY TO LIMIT THE TRANSPORTATION OF SEDIMENTS OUTSIDE THE LIMITS OF THE PROJECT TO THE VOLUME AND AMOUNT AS THOSE THAT EXIST PRIOR TO COMMENCEMENT OF CONSTRUCTION. THIS CONDITION MUST BE SATISFIED UNTIL PROJECT IS FULLY COMPLETED AND ACCEPTED. CONTRACTOR SHALL PROVIDE ROUTINE MAINTENANCE ON TEMPORARY EROSION CONTROL FEATURES AT HIS EXPENSE. PROVISION MUST BE MADE TO PRESERVE THE INTEGRITY AND CAPACITY OF CHECK WEIRS, SEDIMENT BASINS, SLOPE DRAINS, GRADING PATTERNS, ETC. REQUIRED TO MEET THIS PROVISION THROUGH OUT THE LIFE OF CONSTRUCTION. CONTRACTOR SHALL PROVIDE HAY BALES, SILT BARRIERS, MURAFI FILTERS, TEMPORARY GRASSING, ETC., AS REQUIRED TO FULLY COMPLY WITH THE INTENT OF THIS SPECIFICATION. CONTRACTOR SHALL PROVIDE CONTINUOUS MONITORING OF EROSION AND SEDIMENT CONTROLS TAKEN AND SHALL DOCUMENT ALL CORRECTIVE MEASURES. A COPY OF THE APPROVED SWPPP SHALL BE KEPT ON SITE AT ALL TIMES FOR REVIEW BY OWNER'S REPRESENTATIVE AND BY NPDES INSPECTORS. THIS PERMIT MUST BE SUBMITTED TO CITY OF
LEESBURG BY THE CONTRACTOR PRIOR TO THE ISSUANCE OF PERMITS.
4. THE OWNER AND/OR CONTRACTOR SHALL PROVIDE A NOTICE OF INTENT IN ACCORDANCE WITH CRITERIA SET FORTH IN THE NPDES PERMIT
REQUIREMENTS 48 HOURS PRIOR TO BEGINNING CONSTRUCTION, CLEARING, OR DEMOLITION.
5. PROVIDE EFFECTIVE TEMPORARY AND PERMANENT EROSION CONTROL FOLLOWING THE REQUIREMENTS IN SECTION 104 OF THE STATE DEPT. OF TRANSPORTATION STANDARDS SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, LATEST EDITION (F.D.O.T. SECTION 104)
AND FDOT EROSION AND SEDIMENT CONTROL MANUAL AND THE FDEP NPDES REGULATIONS.
6. INLETS AND CATCH BASINS SHALL BE PROTECTED FROM SEDIMENTATION RESULTING FROM SURFACE RUNOFF UNTIL COMPLETION OF ALL CONSTRUCTION OPERATION THAT MAY CAUSE SEDIMENT RUNOFF. FILTER FABRIC SHALL BE PLACED AND MAINTAINED UNDER THE GRATE AND FILTER SOCKS PLACED IN FRONT OF THE THROAT OF CURB INLETS, DURING CONSTRUCTION.
7. TURBIDITY BARRIERS MUST BE INSTALLED AT ALL LOCATIONS WHERE THE POSSIBILITY OF TRANSFERRING SEDIMENTS AND SUSPENDED SOLIDS INTO THE RECEIVING WATER BODY EXISTS DUE TO CONSTRUCTION. TURBIDITY BARRIERS SHALL REMAIN IN PLACE UNTIL CONSTRUCTION IS COMPLETED, SOILS ARE STABILIZED AND VEGETATION HAS BEEN ESTABLISHED.
8. ALL SLOPES 5:1 OR GREATER SHALL BE SODDED. ALL POND SLOPES AND RIGHTS-OF-WAY SHALL BE SODDED.
9. IN ACCORDANCE WITH FDEP AND WATER MANAGEMENT DISTRICT PERMITS, ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED WITHIN
7 DAYS OF NO CONSTRUCTION ACTIVITES.
1. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL CLEARLY DESIGNATE THE LIMITS OF CONSTRUCTION ON-SITE. THE CONTRACTOR
SHALL NOT PERFORM ANY WORK OUTSIDE THE LIMITS OF CONSTRUCTION.
2. THE CONTRACTOR SHALL BE EXTREMELY CAUTIOUS WHEN WORKING NEAR TREES THAT ARE TO BE SAVED, WHETHER SHOWN IN THE PLANS
OR DESIGNATED IN THE FIELD.
3. ALL PRACTICAL AND NECESSARY EFFORT SHALL BE TAKEN DURING CONSTRUCTION TO PREVENT UNNECESSARY TREE REMOVAL.
4. ANY PROPOSED CUT OR FILL MATERIAL TO BE REMOVED OR PLACED WITHIN THE DRIP LINE OF SPECIMEN TREES TO REMAIN, INCLUDING TRENCHING FOR PROPOSED IMPROVEMENTS SUCH AS UTILITIES, WILL REQUIRE THE ADVANCED PRE-TREATMENT OF EACH IMPACTED TREE BY A QUALIFIED ARBORIST OR AT THE DIRECTION OF THE LANDSCAPE ARCHITECT TO MINIMIZE THE POTENTIALLY ADVERSE IMPACTS OF
CONSTRUCTION.
5. TREE PROTECTION BARRICADES OR EQUIVALENT PROTECTIVE MEASURES WILL BE CONSTRUCTED ACCORDING TO THE LOCAL
JURISDICTION'S CRITERIA FOR TREES TO REMAIN WITHIN THE LIMITS OF CONSTRUCTION.
6. IN AREAS REQUIRING FILL MATERIAL, THE CONTRACTOR SHALL STRIP OR OTHERWISE REMOVE ALL VEGETATION SUCH AS BRUSH, HEAVY SODS, HEAVY GROWTH OF GRASS, DECAYED VEGETATION MATTER, RUBBISH AND ANY OTHER DELETERIOUS MATERIAL BEFORE EMBANKMENT IS PLACED. IMMEDIATELY PRIOR TO THE PLACING OF FILL MATERIAL, THE ENTIRE AREA UPON WHICH FILL IS TO BE PLACED, SHALL BE SCARIFIED IN A DIRECTION APPROXIMATELY PARALLEL TO THE AXIS OF FILL. THE GEOTECHNICAL ENGINEER SHALL APPROVE
THE AREA PRIOR TO THE PLACEMENT OF FILL.
7. ANY FENCING REMOVED OR DAMAGED DURING CONSTRUCTION SHALL BE REPLACED.
1. THE CONTRACTOR SHALL PERFORM ALL WORK PERTAINING TO DRAINAGE INCLUDING EXCAVATION OF STORMWATER MANAGEMENT PONDS OR EQUIVALENT FACILITIES PRIOR TO THE COMMENCEMENT OF OTHER WORK INCLUDED IN THESE PLANS.
2. THE CONTRACTOR SHALL STAKE ALL IMPROVEMENTS USING THE RECORD PLAT. THE CONTRACTOR SHALL VERIFY WITH THE ENGINEER THAT THE PLAT IS CORRECT PRIOR TO ANY CONSTRUCTION. IF A PLAT DOES NOT EXIST, CONTRACTOR IS TO VERIFY USE OF THE SURVEY FOR LAYOUT WITH ENGINEER PRIOR TO STARTING WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLETELY STAKE AND CHECK ALL IMPROVEMENTS TO INSURE CORRECT POSITIONING, BOTH HORIZONTAL AND VERTICAL, INCLUDING MINIMUM BUILDING SETBACKS PRIOR TO THE INSTALLATION OF ANY IMPROVEMENT. ANY DISCREPANCY BETWEEN PLATTED INFORMATION AND THE PLANS SHALL BE
REPORTED TO THE ENGINEER IMMEDIATELY AND IN WRITING.
3. PRIOR TO INITIATING ANY EXCAVATION (INCLUDING BUT NOT LIMITED TO TUNNELS, DITCHES, STORM WATER PONDS, CANALS, ARTIFICIAL LAKES) CONTRACTOR SHALL INSTALL FENCES AND TAKE ALL OTHER REASONABLE AND PRUDENT STEPS TO INSURE THAT ACCESS TO
EXCAVATION BY UNAUTHORIZED PERSONNEL IS PREVENTED.
4. ALL DRAINAGE STRUCTURES ARE TO BE TRAFFIC BEARING UNLESS OTHERWISE NOTED. ALL PRECAST CIRCULAR STRUCTURES SHALL BE
CONSTRUCTED WITH A MINIMUM 5-INCH WALL THICKNESS.
5. ALL PROPOSED PAVING SURFACES IN INTERSECTIONS AND ADJACENT EXISTING SECTIONS SHALL BE GRADED TO DRAIN POSITIVELY IN THE DIRECTION SHOWN BY THE PROPOSED GRADES AND FLOW ARROWS ON THE PLANS AND TO PROVIDE A SMOOTHLY TRANSITIONED DRIVING SURFACE FOR VEHICLES WITH NO SHARP BREAKS IN GRADE, AND NO UNUSUALLY STEEP OR REVERSE CROSS SLOPES. APPROACHES TO INTERSECTIONS AND ENTRANCE AND EXIT GRADES TO INTERSECTIONS MAY REQUIRE MINOR LOCAL FIELD ADJUSTMENTS SHOULD ACTUAL CONDITIONS VARY FROM THE SURVEYED INFORMATION THE DESIGN WAS BASED UPON IN ORDER TO ACCOMPLISH THE INTENT OF THE PLANS.
IN ADDITION, THE STANDARD CROWN WILL HAVE TO BE CHANGED IN ORDER TO DRAIN POSITIVELY IN THE AREA OF INTERSECTIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ACCOMPLISH THE ABOVE AND CONSULT THE ENGINEER AS NEEDED TO MAKE ANY AND ALL REQUIRED INTERPRETATIONS OF THE PLANS OR GIVE SUPPLEMENTARY INSTRUCTIONS SHOULD THE INTENT OF THE PLANS BE UNCLEAR.
6. CONSTRUCTION OF ROADWAYS SHALL MEET THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE LOCAL AGENCY(S) HAVING JURISDICTION AND THE MINIMUM SUGGESTED SECTIONS AS OUTLINED IN THE SOILS REPORT'S RECOMMENDATIONS, UNLESS OTHERWISE
NOTED.
7. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING ANY EXCESS CUTS OR SUPPLYING FILL AS NECESSARY TO GRADE THE SITE TO THE PROPOSED ELEVATIONS AS DESIGNED WITHIN THE CONSTRUCTION DOCUMENTS. FLORIDA LAW (F.S. 556) UNDERGROUND FACILITY DAMAGE PREVENTION AND SAFETY ACT MANDATES THAT EXCAVATORS/CONTRACTORS SHALL CONTACT SUNSHINE 811 (FKA: SUNSHINE STATE ONE-CALL OF FLORIDA) BY CALLING 800-432-4770 OR 811 AT LEAST 2 FULL BUSINESS DAYS PRIOR TO BEGINNING ANY EXCAVATION OR DEMOLITION TO ALLOW MEMBER OPERATORS AN OPPORTUNITY TO IDENTIFY AND MARK THEIR UNDERGROUND FACILITIES AND APPROPRIATELY RESPONSE TO THE POSITIVE RESPONSE SYSTEM. TRENCHES SHALL CONFORM WITH THE REQUIREMENTS OF THE
FLORIDA TRENCH SAFETY ACT (F.S. 553, PART III).
8. IF LIMESTONE BEDROCK IS ENCOUNTERED DURING EXCAVATION OF THE RETENTION BASINS OR A SINKHOLE OR SOLUTION CAVITY FORMS DURING CONSTRUCTION, EXCAVATION OF THE BASIN MUST BE HALTED IMMEDIATELY, THE OWNER, ENGINEER, AND WATER MANAGEMENT DISTRICT MUST BE NOTIFIED, AND REMEDIAL ACTION WILL BE REQUIRED. THE PERMITEE MUST INSPECT ALL PERMITTED SURFACE WATER MANAGEMENT BASINS MONTHLY FOR THE OCCURRENCE OF SINKHOLES AND DOCUMENT THESE INSPECTIONS ON WATER MANAGEMENT DISTRICT CONDITION COMPLIANCE FORM NUMBER EN-33. TWO COPIES OF THE COMPLETED FORMS MUST BE SENT TO THE WATER MANAGEMENT DISTRICT AND THE LOCAL AGENCY HAVING JURISDICTION ANNUALLY BY MAY 31ST. OF EACH YEAR. THE PERMITEE MUST REPORT ANY SINKHOLE THAT DEVELOPS WITHIN THE SURFACE WATER MANAGEMENT SYSTEM. THE PERMITEE MUST NOTIFY THE WATER MANAGEMENT DISTRICT AND LOCAL AGENCY HAVING JURISDICTION OF ANY SINKHOLE DEVELOPMENT IN THE SURFACE WATER MANAGEMENT SYSTEM WITHIN 48 HOURS OF ITS DISCOVERY AND COMPLETE SINKHOLE REPAIR WITHIN 10 DAYS OF SUCH DISCOVERY
USING A DISTRICT APPROVED METHODOLOGY.
9. AFTER THE ROADWAY HAS BEEN CONSTRUCTED TO SUBGRADE, IT SHALL BE PROOF-ROLLED TO ASSURE THAT PROPER COMPACTION HAS BEEN ATTAINED. THE PROOF-ROLLING AND COMPACTION OPERATIONS SHALL BE INSPECTED AND TESTED BY A FLORIDA LICENSED GEOTECHNICAL ENGINEER TO ASSURE THAT THE SPECIFIED COMPACTION IS MAINTAINED AND ALL DELETERIOUS MATERIALS HAVE BEEN
REMOVED.
10. THE CONTRACTOR SHALL INSURE THAT A MINIMUM SOIL DENSITY OF 98% COMPACTION IS ACHIEVED UNLESS OTHERWISE NOTED FOR PLACEMENT OF ALL HEADWALL/ENDWALL FOOTINGS, RETAINING WALL FOOTINGS, AND IN GENERAL, ANY FOOTING SUPPORT DESCRIBED ON THESE PLANS. IT WILL ALSO BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSURE THAT SUFFICIENT GEOTECHNICAL TESTING AND
DESIGN HAS BEEN PERFORMED PRIOR TO CONSTRUCTION.
11. STORM PIPE LENGTHS SHOWN ON THE PLANS INCLUDE MITERED END SECTIONS. IF THE CONTRACTOR ELECTS TO USE AN APPROVED
ALTERNATE, THE PIPE LENGTHS MUST BE ADJUSTED.
12. INLET OFFSETS ARE TO THE CENTERLINES SHOWN ON F.D.O.T. DESIGN STANDARDS INDEXES.
13. THE CONTRACTOR IS RESPONSIBLE FOR PAVING ALL ROADWAYS TO DRAIN POSITIVELY. INTERSECTIONS SHALL BE TRANSITIONED TO PROVIDE A SMOOTH DRIVING SURFACE WHILE MAINTAINING POSITIVE DRAINAGE. IF AN AREA OF POOR DRAINAGE IS OBSERVED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER PRIOR TO PAVING SO THAT A SOLUTION OR RECOMMENDATION FOR CORRECTION MAY BE
MADE.
14. ALL REINFORCED CONCRETE PIPE (R.C.P.) SHALL BE MINIMUM CLASS III , UNLESS OTHERWISE APPROVED OR NOTED ON THE PLANS OR
SPECIFICATIONS.
15. ALL STORMWATER PIPE JOINTS SHALL BE WRAPPED WITH FILTER FABRIC.
1. THE CONTRACTOR SHALL COORDINATE ALL WORK WITHIN PUBLIC RIGHTS-OF-WAY WITH THE RESPECTIVE LOCAL AGENCY(S) HAVING JURISDICTION (CITY OR COUNTY) DIRECTOR OF PUBLIC WORKS AND THE JURISDICTION'S ENGINEER. IN ADDITION, ANY WORK WITHIN A STATE ROAD RIGHT-OF-WAY MUST BE APPROVED AND COORDINATED WITH THE FDOT THROUGH THE LOCAL MAINTENANCE OFFICE FOR
EACH DISTRICT.
2. PRIOR TO PERFORMING ANY WORK WITHIN ANY PUBLIC OR UTILITY RIGHT-OF-WAY, CONTRACTOR SHALL OBTAIN AUTHORIZATION AND
PERMIT FROM ALL JURISDICTIONS RESPONSIBLE FOR SUCH RIGHT-OF-WAY.
3. PRIOR TO PERFORMING ANY WORK WITHIN ANY PUBLIC RIGHT-OF-WAY, CONTRACTOR SHALL DEVELOP AND SUBMIT A MAINTENANCE OF TRAFFIC PLAN TO THE LOCAL AGENCY HAVING JURISDICTION OVER SAID ROW FOR THEIR APPROVAL. THIS PLAN MUST MEET THE MINIMUM REQUIREMENTS AS OUTLINED IN THE "MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES" PUBLISHED BY THE U.S. DEPARTMENT OF TRANSPORTATION, FEDERAL HIGHWAY ADMINISTRATION AND THE FLORIDA DEPARTMENT OF TRANSPORTATION DESIGN STANDARDS.
UTILITY PROVIDERS:
WATER: --------------------------
RECLAIMED WATER: -------
SANITARY SEWER: ----------
SOLID WASTE: ----------------
ELECTRIC: ----------------------
TELEPHONE: ------------------
CABLE: ---------------------------
GAS: ------------------------------
CITY OF LEESBURG
CENTURYLINK
COMCAST COMMUNICATION
CITY OF LEESBURG
1. THE EXISTING UTILITIES SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD LOCATE ALL EXISTING UTILITIES AS TO SIZE, LOCATION, AND ELEVATION. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY AND ALL CONFLICTS PRIOR TO BEGINNING
CONSTRUCTION.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND VERIFYING SIZE, TYPE, LOCATION, AND ELEVATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION AND NOTIFYING THE INVOLVED UTILITY PROVIDERS TO MAKE ANY NECESSARY ARRANGEMENTS FOR RELOCATION, DISRUPTION OF SERVICE, OR CLARIFICATION OF ACTIVITY REGARDING SAID UTILITY. THE CONTRACTOR SHALL USE EXTREME CAUTION WHEN CROSSING AN UNDERGROUND UTILITY, WHETHER SHOWN ON THESE PLANS OR FIELD LOCATED. THE RESPECTIVE UTILITY PROVIDERS SHALL RELOCATE UTILITIES THAT INTERFERE WITH THE PROPOSED CONSTRUCTION AND THE CONTRACTOR SHALL COOPERATE WITH THE UTILITY PROVIDERS DURING RELOCATION OPERATIONS. ANY DELAY OR INCONVENIENCE CAUSED BY THE INVOLVED UTILITIES SHALL BE INCIDENTAL TO THE CONTRACT. THE CONTRACTOR SHALL CONFORM TO FLORIDA
STATUTE CHAPTER 556 AND SUNSHINE 811.
3. FLORIDA LAW (F.S.556) UNDERGROUND FACILITY DAMAGE PREVENTION AND SAFETY ACT MANDATES THAT EXCAVATORS/CONTRACTORS SHALL CONTACT SUNSHINE 811 (FKA: SUNSHINE STATE ONE-CALL OF FLORIDA) BY CALLING 800-4432-4770 OR 811 AT LEAST 2 FULL BUSINESS DAYS PRIOR TO BEGINNING ANY EXCAVATION OR DEMOLITION TO ALLOW MEMBER OPERATORS AN OPPORTUNITY TO IDENTIFY AND MARK THEIR UNDERGROUND FACILITIES AND APPROPRIATELY RESPONSE TO THE POSITIVE RESPONSE SYSTEM.
4. UTILITY SERVICES TO THE PROPOSED BUILDING(S) SHALL TERMINATE 5 FEET OUTSIDE OF THE BUILDING UNLESS OTHERWISE NOTED.
PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL REVIEW BUILDING ARCHITECTURAL AND PLUMBING PLANS TO VERIFY PROPER CONTINUATION OF THE PROPOSED UTILITIES FOR LOCATION, ALIGNMENT AND ELEVATION(S) FOR EACH SERVICE TO THE BUILDING(S).
SHOULD UTILITY SERVICE LATERALS SHOWN ON THE SITE CIVIL CONSTRUCTION PLANS NOT CORRESPOND WITH BUILDING ARCHITECTURAL OR PLUMBING PLANS THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY.
5. THE POWER DISTRIBUTION SYSTEM SHALL BE DESIGNED AND INSTALLED BY THE POWER SERVICE PROVIDER. THE CONTRACTOR SHALL COORDINATE WITH SAID POWER SERVICE PROVIDER TO INSURE PROPER CONSTRUCTION PHASING IS ACHIEVED, AND TO ALLOW THE INSTALLATION OF STREET CROSSINGS, SLEEVES, CONDUITS, POLES, TRANSFORMERS, AND OTHER REQUIRED EQUIPMENT. IT IS THE OWNER'S RESPONSIBILITY TO ACQUIRE ANY NECESSARY EASEMENTS AS A RESULT OF THE POWER SERVICE PROVIDER'S DESIGN AND
RESPECTIVE INSTALLATION LOCATIONS.
6. THE TELEPHONE, CABLE TV, DATA, AND/OR COMMUNICATION SYSTEMS SHALL BE DESIGNED AND INSTALLED BY THEIR RESPECTIVE SERVICE PROVIDER. THE CONTRACTOR SHALL COORDINATE WITH SAID SERVICE PROVIDER TO INSURE PROPER CONSTRUCTION PHASING IS ACHIEVED, CONFLICT FREE, AND TO ALLOW THE INSTALLATION OF STREET CROSSINGS, SLEEVES, CONDUITS, POLES, AND OTHER REQUIRED EQUIPMENT. IT IS THE OWNER'S RESPONSIBILITY TO ACQUIRE ANY NECESSARY EASEMENTS AS A RESULT OF THE
SERVICE PROVIDERS' DESIGNS AND RESPECTIVE INSTALLATION LOCATIONS.
7. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROPERLY COORDINATE THE FINAL DESIGNS AND SUBSEQUENT INSTALLATIONS OF ALL SERVICE PROVIDERS' UTILITIES AND THEIR MINIMUM CRITERIA AS SET FORTH THEREIN FOR ITEMS SUCH AS MAINTAINING THE MINIMUM
SEPARATION DISTANCES BETWEEN THE VARIOUS UTILITIES.
8. UNLESS OTHERWISE NOTED, THE TOP 24 INCHES OF ALL UTILITY TRENCHES WITHIN ROADWAYS IN MAXIMUM 12" LIFTS, SHALL BE COMPACTED TO 98% OF THE MODIFIED PROCTOR MAXIMUM DENSITY; ALL OTHER UTILITY TRENCHES SHALL BE COMPACTED TO 95% OF
THE MODIFIED PROCTOR MAXIMUM DENSITY.
9. THE CONTRACTOR SHALL NOTIFY THE APPLICABLE UTILITIES CONSTRUCTION DEPARTMENT FOR THE CORRESPONDING LOCAL UTILITY PROVIDED A MINIMUM OF 2 BUSINESS DAYS PRIOR TO STARTING ANY UTILITIES CONSTRUCTION.
10. PIPE ALIGNMENT, DEFLECTION, AND INTEGRITY TESTING SHALL BE PERFORMED BY THE 'LAMPING' METHOD AND UTILIZING VIDEO INSPECTION. THE CONTRACTOR SHALL PERFORM INTERNAL VIDEO INSPECTION FOR THE GRAVITY SEWER TO CHECK PIPE ALIGNMENT
AND DEFLECTION.
XXX
CITY OF LEESBURG
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SEAL
C
IT
Y O
F
LE
ES
BU
R G
C
AR
VE
R
H
EI
G H
TS
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
FE
AS
IB
IL
IT
Y
ST
U D
Y
LA
KE
C O
U N
TY
, F
LO
R
ID
A
LKW
JDP
AM
50185663
OF ...Q
:\C ity o f L ee sb ur g\ C ar ve r H ei gh ts D ra in ag e
TB
D
\C A
D \d w g\
G en er al
N ot es .d w g
P
LO
TS
TY
LE
TA
B
LE
: D C
S .C
TB
P
LO
TT
E
D : 1
0/ 6/
:0
M
TT
E
D B
Y : W
E
LC
H , K
E V
IN
SCALE
P.E. JEFFREY D. PEQUEEN 47664P.E. No.
FINAL
DRAWINGS
CITY OF LEESBURG
CITY OF LEESBURG
+0
+0
+0
+0
+0
+0
+0
+0
+0
+0
30+00 31+00 32+00 33+00 34+00 35+00 36+00 36+64
40+00 41+00 42+00 43+00 44+00 45+00 46+00 46+65
L3 L5
L4
L6
JO
H
N S
AV
EN
U E
GEORGIA AVENUE
TALLADEGA STREET
W
AI
TM
AN
A
VE
N U
E
GEORGIA AVENUE
TALLADEGA STREET
30'0' 60'
SCALE: 1" = 30'
15'
EXISTING
CONDITIONS
& CONTROL
G-003
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SEAL
C
IT
Y O
F
LE
ES
BU
R G
C
AR
VE
R
H
EI
G H
TS
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
FE
AS
IB
IL
IT
Y
ST
U D
Y
LA
KE
C O
U N
TY
, F
LO
R
ID
A
LKW
JDP
AM
50185663
OF ...Q
:\C ity o f L ee sb ur g\ C ar ve r H ei gh ts D ra in ag e
TB
D
\C A
D \d w g\
C on tr ol
.d w g P
LO
TS
TY
LE
TA
B
LE
: D
C S
TT
E D
: 1 0/
6/
:0
TT
E D
B Y
: W E
LC
H
, K E
V
IN
SCALE
P.E. JEFFREY D. PEQUEEN 47664P.E. No.
FINAL
DRAWINGS
LINE TABLE
NUMBER
L3
L4
L5
L6
BEARING
S89°08'32"E
S89°21'42"E
S00°51'28"W
S00°51'28"W
LENGTH (FT)
305.00
305.00
663.64
664.81
START POINT
N1633062.6441 E368508.1473
N1632397.9088 E368498.1941
N1633058.0780 E368813.1121
N1633062.6441 E368508.1473
END POINT
N1633058.0780 E368813.1121
N1632394.5115 E368803.1763
N1632394.5115 E368803.1763
N1632397.9088 E368498.1941
AutoCAD SHX Text
AIR CONDITIONER
AutoCAD SHX Text
BAKCFLOW PREVENTER
AutoCAD SHX Text
BAKCFLOW PREVENTER
AutoCAD SHX Text
BAKCFLOW PREVENTER
AutoCAD SHX Text
BAKCFLOW PREVENTER
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
SHED
AutoCAD SHX Text
SHED
AutoCAD SHX Text
INLET TOP=71.21' W.INV.=66.73' E.INV.=66.73'
AutoCAD SHX Text
INLET TOP=70.59' S.INV.=68.19'
AutoCAD SHX Text
INLET TOP=70.46' N.INV.=67.73' E.INV.=67.69' W.INV.=67.67'
AutoCAD SHX Text
INLET TOP=70.69' E.INV.=67.87' W.INV.=67.87'
AutoCAD SHX Text
INLET TOP=69.84' N.INV.=69.01'
AutoCAD SHX Text
INLET TOP=70.93' BOTTOM=66.49'
AutoCAD SHX Text
INLET TOP=70.70' S.INV.=67.99'
AutoCAD SHX Text
INLET TOP=70.44' N.INV.=67.84' W.INV.=67.94'
AutoCAD SHX Text
INLET TOP=71.58' W.INV.=67.34'
AutoCAD SHX Text
INLET TOP=71.88' (FILLED WITH SAND)
AutoCAD SHX Text
INLET TOP=70.84' E.INV.=68.79' W.INV.=67.89' S.INV.=67.63'
AutoCAD SHX Text
EDGE OF WATER ELEVATION = 69.4' (1/12/2025)
AutoCAD SHX Text
SANITARY MANHOLE RIM=71.57'
AutoCAD SHX Text
SANITARY MANHOLE RIM=71.68'
AutoCAD SHX Text
SANITARY MANHOLE RIM=71.43'
AutoCAD SHX Text
SANITARY MANHOLE RIM=71.15'
AutoCAD SHX Text
SANITARY MANHOLE RIM=72.69'
AutoCAD SHX Text
STORM MANHOLE RIM=72.77'
AutoCAD SHX Text
STORM MANHOLE RIM=72.71' N.INV.=65.75' W.INV.=63.98' BOTTOM=63.98'
AutoCAD SHX Text
BRICK PLANTER
AutoCAD SHX Text
SIGN: JOHNS AVE/GEORGIA AVE
AutoCAD SHX Text
SIGN: TURN AHEAD/SPEED LIMIT 15MPH
AutoCAD SHX Text
SIGN: LEFT OR RIGHT TURN
AutoCAD SHX Text
SIGN: NO PARKING
AutoCAD SHX Text
SIGN: SPEED LIMIT 25MPH
AutoCAD SHX Text
SIGN: SPEED LIMIT 25MPH
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
STOP SIGN
AutoCAD SHX Text
INV.=66.89'
AutoCAD SHX Text
INV.=66.88'
AutoCAD SHX Text
INV.=68.81'
AutoCAD SHX Text
M.E.S. INV.48"RCP UNATTAINABLE
AutoCAD SHX Text M.E.S.
AutoCAD SHX Text M.E.S.
AutoCAD SHX Text
8"PVC
AutoCAD SHX Text
48"RCP
AutoCAD SHX Text
PIPE SIZE AND TYPE UNKNOWN
AutoCAD SHX Text
PIPE SIZE AND TYPE UNKNOWN
AutoCAD SHX Text
6"PVC
AutoCAD SHX Text
42"CMP
AutoCAD SHX Text
42"CMP
AutoCAD SHX Text
42"CMP
AutoCAD SHX Text
42"CMP
AutoCAD SHX Text
30"CMP
AutoCAD SHX Text
30"CMP
AutoCAD SHX Text
30"CMP
AutoCAD SHX Text
30"CMP
AutoCAD SHX Text
12"CMP
AutoCAD SHX Text
18"CMP
AutoCAD SHX Text
24"CMP
AutoCAD SHX Text
18"CMP
AutoCAD SHX Text
24"CMP
AutoCAD SHX Text
12"CMP
AutoCAD SHX Text SITE BENCHMARK (800) SET 4"x4" CONCRETE MONUMENT STAMPED "DEWBERRY TRAV PT LB 8011" NORTHING: 1632707.24' EASTING: 368761.26' ELEV: 71.01'71.01'
AutoCAD SHX Text SITE BENCHMARK (801) SET 4"x4" CONCRETE MONUMENT STAMPED "DEWBERRY TRAV PT LB 8011" NORTHING: 1632337.97' EASTING: 368772.93' ELEV: 72.98'72.98'
AutoCAD SHX Text PID #27-26-32-711006-004070 OWNER: CROWLEY, CAROLINE CROWLEY, CAROLINE SPILLANE MORB 13273, PG 1135
AutoCAD SHX Text PID #221924000300012700 OWNER: CITY OF LEESBURG CITY OF LEESBURG ORB 1680, PG 2387
AutoCAD SHX Text
PID #221924080000F00600 OWNER: HALL TAMEKA M ORB 3460, PG 257
AutoCAD SHX Text
PID #221924080000F00500 OWNER: RUCIEZ LLC ORB 6124, PG 219
AutoCAD SHX Text
PID #221924080000F00400 OWNER: EWING WILLIAM T ORB 5376, PG 2065
AutoCAD SHX Text
PID #221924080000F00300 OWNER: CASTILLO NATHALIA E ORB 5619, PG 1203
AutoCAD SHX Text PID #221924080000F00100 OWNER: LITTLE JOHN TWYINE LITTLE JOHN TWYINE ORB 1761, PG 956
AutoCAD SHX Text
PID #221924080000G00400 OWNER: CONNER KEVIN ORB 2001, PG 38
AutoCAD SHX Text
PID #221924080000G00200 OWNER: EDWARDS CHRISTOPHER ORB 3875, PG 1111
AutoCAD SHX Text
PID #221924080000G00100 OWNER: EDWARDS CHRISTOPHER ORB 3875, PG 1111
AutoCAD SHX Text
PID #221924080000A01200 OWNER: BONDS LINDA M BONDS LINDA M ORB 4888, PG 1463
AutoCAD SHX Text PID #221924080000A01300 OWNER: VPI FINANCIAL LLC VPI FINANCIAL LLC ORB 6438, PG 314
AutoCAD SHX Text PID #221924080000A01400 OWNER: MOSLEY ERNESTINE MOSLEY ERNESTINE ESTATE ORB 744, PG 2109
AutoCAD SHX Text PID #221924080000A01500 OWNER: HAMILTON CHRISTYNE B HAMILTON CHRISTYNE B TRUSTEE ORB 1618, PG 1560
AutoCAD SHX Text PID #221924080000E01100 OWNER: GREENIDGE KATIE BELL GREENIDGE KATIE BELL ESTATE ORB 359, PG 125
AutoCAD SHX Text PID #221924080000E01101 OWNER: JACKSON DOROTHY JACKSON DOROTHY LIFE ESTATE ORB 6357, PG 1744
AutoCAD SHX Text PID #221924080000E00100 OWNER: CONNER ABRAHAM CONNER ABRAHAM & JOHNNIE M LIFE ESTATE ORB 6418, PG 416
AutoCAD SHX Text
PID #221924080000E00400 OWNER: WRIGHT AUDREY D WRIGHT AUDREY D ORB 2191, PG 76
AutoCAD SHX Text
PID #221924080000E00500 OWNER: ADLAM MICHAEL ADLAM MICHAEL ORB 4125, PG 1045
AutoCAD SHX Text PID #221924080000E00600 OWNER: TORRES PAOLA B TORRES PAOLA B & JULIO A ORTIZ COLON ORB 6156, PG 1593
AutoCAD SHX Text PID #221924080000E00700 OWNER: CITY OF LEESBURG CITY OF LEESBURG ORB 3377, PG 1330
AutoCAD SHX Text
PID #221924080000E00800 OWNER: WILSON COREY K WILSON COREY K ORB 5471, PG 62
AutoCAD SHX Text PID #221924080000E00900 OWNER: CONNER ABRAHAM CONNER ABRAHAM & JOHNNIE M LIFE ESTATE ORB 6418, PG 408
AutoCAD SHX Text
PID #221924080000B00800 OWNER: HAWKEYE HAWKEYE PARTNERS II LLC ORB 4380, PG 583
AutoCAD SHX Text PID #221924080000B01000 OWNER: CHRISTIAN CHRISTIAN WORSHIP CENTER OF CENTRAL FLORIDA INC ORB 6410, PG 821
AutoCAD SHX Text
PID #221924080000B01200 OWNER: GRIFFIN LAKESHA GRIFFIN LAKESHA ORB 6421, PG 2125
AutoCAD SHX Text PID #221924080000B01100 OWNER: CHRISTIAN CHRISTIAN WORSHIP CENTER OF CENTRAL FLORIDA INC ORB 6410, PG 821
AutoCAD SHX Text
PID #221924080000B01300 OWNER: WADE LIZZIE WADE LIZZIE ORB 1221, PG 502
AutoCAD SHX Text PID #221924000300012700 OWNER: CITY OF LEESBURG CITY OF LEESBURG ORB 1680, PG 2387
AutoCAD SHX Text
PID #221924200000000100 OWNER: SINCLAIR AARON SINCLAIR AARON ORB 5327, PG 1999
AutoCAD SHX Text
PID #221924200000000200 OWNER: SMITH LESIA R SMITH LESIA R ORB 2209, PG 1301
AutoCAD SHX Text PID #221924200000000300 OWNER: AMY L EISMONT AND AMY L EISMONT AND HOWARD W SHOEMAKER TRUST ORB 6144, PG 2071
AutoCAD SHX Text PID #221924080000C01300 OWNER: CONNER ABRAHAM CONNER ABRAHAM & JOHNNIE LIFE ESTATE ORB 6418, PG 416
AutoCAD SHX Text PID #221924200000000400 OWNER: SANDERS CAMERON SANDERS CAMERON T & CARLA ORB 3089, PG 1067
AutoCAD SHX Text
PID #221924080000D00500 OWNER: BOOST MARK BOOST MARK ORB 4797, PG 1299
AutoCAD SHX Text
PID #221924080000D00400 OWNER: TYNDELL OLA MAE TYNDELL OLA MAE ORB 1567, PG 92
AutoCAD SHX Text
PID #221924080000D00300 OWNER: TYNDELL OLA MAE TYNDELL OLA MAE ORB 4643, PG 2491
AutoCAD SHX Text
PID #221924080000D00200 OWNER: LAW KIWANIS LAW KIWANIS ORB 4089, PG 1036
AutoCAD SHX Text
PID #221924080000D00000 OWNER: LOPEZ EDWARD D LOPEZ EDWARD D ORB 5096, PG 898
AutoCAD SHX Text
PID #221924080000D00700 OWNER: PARKER JOYCE L PARKER JOYCE L ORB 1673, PG 2053
AutoCAD SHX Text
PID #221924080000D00800 OWNER: VSP ORLANDO LLC VSP ORLANDO LLC ORB 5440, PG 1434
AutoCAD SHX Text
PID #221924080000D00900 OWNER: NIBLACK SIMONIA NIBLACK SIMONIA ORB 1824, PG 2006
AutoCAD SHX Text
PID #221924080000D01000 OWNER: HURST LESLIE O HURST LESLIE O ORB 5324, PG 454
AutoCAD SHX Text PID #221924080000D01100 OWNER: MONTOUTE TRALONIE MONTOUTE TRALONIE ORB 2215, PG 1342
AutoCAD SHX Text
6' TALL PVC FENCE
AutoCAD SHX Text
6' TALL WOOD FENCE
AutoCAD SHX Text
6' TALL PVC FENCE
AutoCAD SHX Text
6' TALL WOOD FENCE
AutoCAD SHX Text
GAS PUMP ISLAND
AutoCAD SHX Text
GAZEBO
AutoCAD SHX Text
GAZEBO
AutoCAD SHX Text
GAZEBO
AutoCAD SHX Text
GAZEBO
AutoCAD SHX Text
VVH 4 FOUND: 3.5" O/D PVC (BURIED ELECTRIC) 2.00' B.G. GROUND ELEV: 71.63'
AutoCAD SHX Text
VVH 3 FOUND: 2.5" O/D PVC (UNKNOWN UTILITY) 1.50' B.G. GROUND ELEV: 71.55'
AutoCAD SHX Text
ELECTRIC JUNCTION BOX
AutoCAD SHX Text
SEWER VALVE
AutoCAD SHX Text
VVH 1 FOUND: 6.5" O/D PVC (FORCE MAIN) 2.60' B.G. GROUND ELEV: 71.60'
AutoCAD SHX Text
VVH 2 FOUND: 2.0" O/D PVC (UNKNOWN UTILITY) 3.00' B.G. GROUND ELEV: 71.62'
AutoCAD SHX Text LEGEND B.G. BELOW GROUND BELOW GROUND O/D OUTER DIAMETER OUTER DIAMETER VVH VERIFIED VERTICAL HEIGHT VERIFIED VERTICAL HEIGHT PVC POLYVINYL CHLORIDE POLYVINYL CHLORIDE ELEV ELEVATION ELEVATION HDPE HIGH DENSITY POLYETHYLENEHIGH DENSITY POLYETHYLENE
AutoCAD SHX Text
VVH 5 FOUND: 2.5" O/D COATED STEEL (GAS MAIN) 2.00' B.G. GROUND ELEV: 71.65'
AutoCAD SHX Text
VVH 6 FOUND: 1.5" O/D PVC (BURIED ELECTRIC) 2.20' B.G. GROUND ELEV: 71.28'
AutoCAD SHX Text
VVH 7 FOUND: 6.5" O/D PVC (FORCE MAIN) 5.00' B.G. GROUND ELEV: 71.42'
AutoCAD SHX Text
VVH 11 FOUND: 1" O/D HDPE (WATER LINE) 0.5' B.G. GROUND ELEV: 70.40
AutoCAD SHX Text
VVH 9 FOUND: 6.5" O/D METAL (UNKNOWN UTILITY) 4.10' B.G. GROUND ELEV: 70.67'
AutoCAD SHX Text
VVH 8 FOUND: 6.5" O/D PVC (FORCE MAIN) 3.80' B.G. GROUND ELEV: 70.83'
AutoCAD SHX Text
VVH 10 FOUND: 1" O/D HDPE (WATER LINE) 1.35' B.G. GROUND ELEV: 70.84'
AutoCAD SHX Text SURVEYOR'S NOTES: 1. THIS SURVEY IS REFERENCED TO FLORIDA STATE PLANE COORDINATES, EAST ZONE, NAD 1983/2011, U.S. SURVEY FEET. 2. VERTICAL DATUM SHOWN HEREON IS REFERENCED TO NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88). 3. THIS SURVEY, MAP, AND REPORT IS NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 4. NO TITLE SEARCH, TITLE OPINION OR ABSTRACT WAS PERFORMED BY, NOR PROVIDED TO DEWBERRY ENGINEERS INC. FOR THE SUBJECT PROPERTY. THERE MAY BE DEEDS OF RECORD, UNRECORDED DEEDS, EASEMENTS, ENCROACHMENTS, RIGHT-OF-WAYS, BUILDING SETBACKS, RESTRICTIVE COVENANTS OR OTHER INSTRUMENTS WHICH COULD AFFECT THE BOUNDARIES OR USE OF THE SUBJECT PROPERTY. 5. NO ATTEMPT HAS BEEN MADE BY DEWBERRY ENGINEERS INC. TO LOCATE OR DETERMINE UNDERGROUND UTILITIES, UTILITY LINES, FOUNDATIONS, OR OTHER UNDERGROUND STRUCTURES, EXCEPT AS SHOWN. 6. NO ATTEMPT HAS BEEN MADE BY DEWBERRY ENGINEERS INC. TO LOCATE OR DETERMINE ENVIRONMENTAL WETLAND LINES, IF ANY EXIST. 7. THERE MAY BE ADDITIONAL RESTRICTIONS NOT SHOWN ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF LAKE COUNTY, FLORIDA. 8. DATE OF FIELD SURVEY: JANUARY 13, 2025.DATE OF FIELD SURVEY: JANUARY 13, 2025.
AutoCAD SHX Text
%%UTEMPORARY SITE CONTROL POINTS:
AutoCAD SHX Text DESCRIPTION NORTHING EASTING ELEV. (NAVD 1988) NORTHING EASTING ELEV. (NAVD 1988) EASTING ELEV. (NAVD 1988) ELEV. (NAVD 1988) 800 SET 4"x4" CONCRETE MONUMENT 1632707.24' 368761.26' 71.01' SET 4"x4" CONCRETE MONUMENT 1632707.24' 368761.26' 71.01' 1632707.24' 368761.26' 71.01' 368761.26' 71.01' 71.01' STAMPED "DEWBERRY TRAV PT LB 8011" 801 SET 4"x4" CONCRETE MONUMENT 1632337.97' 368772.93' 72.98' SET 4"x4" CONCRETE MONUMENT 1632337.97' 368772.93' 72.98' 1632337.97' 368772.93' 72.98' 368772.93' 72.98' 72.98' STAMPED "DEWBERRY TRAV PT LB 8011"
AutoCAD SHX Text
%%USOURCE CONTROL POINTS: (NOT GRAPHICALLY SHOWN)
DESCRIPTION NORTHING EASTING ELEV. (NAVD 1988) NORTHING EASTING ELEV. (NAVD 1988) EASTING ELEV. (NAVD 1988) ELEV. (NAVD 1988) ELEV. (NAVD 1988) Q 431 FOUND CONCRETE MONUMENT 497,020.1(m) 113,352.8(m) 78.99' FOUND CONCRETE MONUMENT 497,020.1(m) 113,352.8(m) 78.99' 497,020.1(m) 113,352.8(m) 78.99' 113,352.8(m) 78.99' 78.99' WITH 3.5" BRASS DISK "Q 431 1994" "Q 431 1994" 08-12-041-0 X CUT IN BOLT HEAD OF FIREHYDRANT 1628752.28' 366238.09' 86.384' X CUT IN BOLT HEAD OF FIREHYDRANT 1628752.28' 366238.09' 86.384' 1628752.28' 366238.09' 86.384' 366238.09' 86.384' 86.384'
JO
H
N S
AV
EN
U E
GEORGIA AVENUE
TALLADEGA STREET
W
AI
TM
AN
A
VE
N U
E
GEORGIA AVENUE
TALLADEGA STREET
40+00 41+00 42+00 43+00 44+00 45+00 46+00 46+65
+0
+0
+0
+0
+0
30+00 31+00 32+00 33+00 34+00 35+00 36+00 36+64
+0
+0
+0
+0
+0
10+50.00
11+00.00
11+50.00
12+00.00
12+50.00
20+50.00
21+00.00
21+50.00
22+00.00
22+50.00
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
+5
0.
+0
0.
SAN FM SAN FM SAN FM SAN FM SAN FM SAN FM
EE
U G
G
AS
UNKUNKUNKUNKUNKUNKUNKUNKUNKUNKUNK
W W W W W W W W W W W W W W W W W W W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW
W W
W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
WWWWWWWWWWWWW
W
WW
E E
E E
E E
E
30'0' 60'
SCALE: 1" = 30'
15'
OVERALL GRADING
PLAN
C-001
1479 Town Center Dr Suite D214 Lakeland, FL 33803 863.345.0838
CA #8794
Dewberry Engineers Inc.
C
B
A
D
E
APPROVED BY
CHECKED BY
SHEET NO.
DRAWN BY
DATE
PROJECT NO.
NO. DESCRIPTION DATE
TITLE
REVISIONS
SEAL
C
IT
Y O
F
LE
ES
BU
R G
C
AR
VE
R
H
EI
G H
TS
ST
O R
M W
AT
ER
IM
PR
O
VE
M
EN
TS
FE
AS
IB
IL
IT
Y
ST
U D
Y
LA
KE
C O
U N
TY
, F
LO
R
ID
A
LKW
JDP
AM
50185663
OF ...Q
:\C ity o f L ee sb ur g\ C ar ve r H ei gh ts D ra in ag e
TB
D
\C A
D \d w g\
G ra di ng
.d w g P
LO
TS
TY
LE
TA
B
LE
: D
C S
TT
E D
: 1 0/
6/
:0
TT
E D
B Y
: W E
LC
H
, K E
V
IN
SCALE
P.E. JEFFREY D. PEQUEEN 47664P.E. No.
FINAL
DRAWINGS
PROPOSED 2' MIAMI GUTTER
PROPOSED 2' MIAMI GUTTER
PROPOSED 4' SIDEWALK
PROPOSED 4' SIDEWALK
SIDEWALK EASEMENT REQUIRED
SIDEWALK EASEMENT REQUIRED
SIDEWALK EASEMENT REQUIRED
PROPOSED 2' MIAMI GUTTER SIDEWALK EASEMENT REQUIRED
SIDEWALK EASEMENT REQUIRED
STA 44+61± BEGIN MIAMI GUTTER
STA 46+32± END MIAMI GUTTER
STA 30+39± BEGIN MIAMI GUTTER
STA 36+55± END MIAMI GUTTER
SIDEWALK EASEMENT REQUIRED
70.00 SWALE
70.00 SWALE
69.4 TOP OF GAS
71 69
69 71
4:1
4:1
ENCASE 2.5" GAS MAIN WITH 6" CONC
ALL AROUND FOR A DISTANCE OF 10'
GRADE 2' BOTTOM WITH SWALE WITH
4:1 SIDE SLOPES TO DRAIN TO POND
PROPOSED 10'
DRAINAGE EASEMENT
PROPOSED 4' SIDEWALK
PROPOSED 4' SIDEWALK
RELOCATE EXIST ELECTRICAL LINE
CONST 6' CHAIN LINK FENCE
CONST 14' SWING GATE
EXIST TREES TO BE REMOVED.
COORDINATE WITH OWNER
EXIST GAS MAIN TO BE PROTECTED.
NOTE:
ANY EXIST FENCE THAT IS
DISTURBED MUST BE RESTORED.
AutoCAD SHX Text
AIR CONDITIONER
AutoCAD SHX Text
BAKCFLOW PREVENTER
AutoCAD SHX Text
BAKCFLOW PREVENTER
AutoCAD SHX Text
BAKCFLOW PREVENTER
AutoCAD SHX Text
BAKCFLOW PREVENTER
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
SHED
AutoCAD SHX Text
SHED
AutoCAD SHX Text
INLET TOP=71.21' W.INV.=66.73' E.INV.=66.73'
AutoCAD SHX Text
INLET TOP=70.59' S.INV.=68.19'
AutoCAD SHX Text
INLET TOP=70.46' N.INV.=67.73' E.INV.=67.69' W.INV.=67.67'
AutoCAD SHX Text
INLET TOP=70.69' E.INV.=67.87' W.INV.=67.87'
AutoCAD SHX Text
INLET TOP=69.84' N.INV.=69.01'
AutoCAD SHX Text
INLET TOP=70.93' BOTTOM=66.49'
AutoCAD SHX Text
INLET TOP=70.70' S.INV.=67.99'
AutoCAD SHX Text
INLET TOP=70.44' N.INV.=67.84' W.INV.=67.94'
AutoCAD SHX Text
INLET TOP=71.58' W.INV.=67.34'
AutoCAD SHX Text
INLET TOP=71.88' (FILLED WITH SAND)
AutoCAD SHX Text
INLET TOP=70.84' E.INV.=68.79' W.INV.=67.89' S.INV.=67.63'
AutoCAD SHX Text
EDGE OF WATER ELEVATION = 69.4' (1/12/2025)
AutoCAD SHX Text
SANITARY MANHOLE RIM=71.57'
AutoCAD SHX Text
SANITARY MANHOLE RIM=71.68'
AutoCAD SHX Text
SANITARY MANHOLE RIM=71.43'
AutoCAD SHX Text
SANITARY MANHOLE RIM=71.15'
AutoCAD SHX Text
SANITARY MANHOLE RIM=72.69'
AutoCAD SHX Text
STORM MANHOLE RIM=72.77'
AutoCAD SHX Text
STORM MANHOLE RIM=76.42' E.INV.=64.37' W.INV.=64.17
AutoCAD SHX Text
STORM MANHOLE RIM=72.71' N.INV.=65.75' W.INV.=63.98' BOTTOM=63.98'
AutoCAD SHX Text
BRICK PLANTER
AutoCAD SHX Text
INV.=66.89'
AutoCAD SHX Text
INV.=66.88'
AutoCAD SHX Text
INV.=68.81'
AutoCAD SHX Text
M.E.S. INV.48"RCP UNATTAINABLE
AutoCAD SHX Text M.E.S.
AutoCAD SHX Text M.E.S.
AutoCAD SHX Text
8"PVC
AutoCAD SHX Text
48"RCP
AutoCAD SHX Text
PIPE SIZE AND TYPE UNKNOWN
AutoCAD SHX Text
PIPE SIZE AND TYPE UNKNOWN
AutoCAD SHX Text
6"PVC
AutoCAD SHX Text
42"CMP
AutoCAD SHX Text
42"CMP
AutoCAD SHX Text
42"CMP
AutoCAD SHX Text
42"CMP
AutoCAD SHX Text
30"CMP
AutoCAD SHX Text
30"CMP
AutoCAD SHX Text
30"CMP
AutoCAD SHX Text
30"CMP
AutoCAD SHX…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .