IA02_Boise ESS Layout.pdf
PDF 1 MB Posted
- Solicitation number
- PANMCC-26-P-0000033396
About this file
This document consists of architectural floor plans and system diagrams for the Boise Military Entrance Processing Station (MEPS) facility, depicting physical security and surveillance infrastructure across two floors.
The first floor plan (approximately 300' x 115') shows the layout of sixteen numbered doors with associated access control components, including card readers, door contacts, request-to-exit sensors, push-to-exit buttons, and magnetic locks distributed throughout the space. The infrastructure includes a 12U cabinet with 24-port switch and 1500VA rack UPS, multiple camera locations (CAM 1, 2, 3, 5), passive infrared sensors, a duress button, siren, wireless transceiver, alarm keypad, master intercom station, and an exit alarm. The second floor plan (approximately 300' x 115') is similarly equipped with ten numbered doors and more extensive surveillance infrastructure, featuring thirty camera positions (CAM 9-30), multiple magnetic locks on three doors, additional security components including alarm panel, duress buttons, strobes, and multiple technical equipment rooms. The system architecture diagram illustrates the interconnected network topology, showing five major control points across the facility: HQ (Room 134), Medical (Room 267), Testing (Room 134), Operations (Room 214), and Control Desk (Room 210). Each location contains networked 32" or 43" decoders, NVR systems, network switches, UPS units (ranging from 1KVA to 2KVA capacity), patch panels, and cable management infrastructure connected through MX8 intercom units and distributed across multiple rooms to support integrated access control, video surveillance, and door intercom operations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U P
U P
U P
U P
U P
U P
Boise MEPS_1st Floor
CR
CR
CR
CR
DR
ID
MS
DC DC
ID
C
CAM 1
C
CAM 3
C
CAM 5
C
CAM 2
• 12U CABINET
• 24 P SWITCH
• 1500 Rack UPS
Door # 11
PTE
REX
Door # 13
PTE
REX
REX
REX
Door # 14
Door # 15
Remove
MX8
LEGEND
DB: Duress Button PIR: Passive Infrared Sensor DR: Door Release Button CR: Card Reader DC: Door Contact A: Exit Alarm TVR: Wireless Transceiver PTE: Push To Exit Button REX: Request To Exit Sensor KP: Alarm Keypad DI: Door Intercom Station MS: Master Intercom Station SR: Siren
KP
• Decoder
• 32"MTR Wall mount
• Mini Tower UPS
TVR
DB
SR
DC
MAGLOCK
DC
Door # 12
DC
DC
DC
Door # 16
A
A
P
STB
PIR
PIRPIR
PIRPIR
300'-0"
CRCR
CRCR
U P
U P
U P
U P
U P
U P
Boise MEPS 2ND FLOOR
CR
CR
CR
CR
MX8
ALARM
PANEL
A
A
CRCR
FE
C
CAM 17
C
CAM 18
C
CAM 20
C
CAM 12
C
CAM 27
C
CAM 11
C
CAM 30
A
CAM 19
MAGLOCK
PTE
PTE MAGLOCK
MAGLOCK
PTE
REX
REX
RB
DR
DR
300'-0"
Door # 5
Door # 6
Door # 7
Door # 8
Door # 10
Door # 2 Door # 3
Door # 4
KP
DC
CR
CR A
C
CAM 23
C
CAM 21
C
CAM 9
DC DC
DC
DC
CAM 29
DC
DCDC
DC
DC
• 12U CABINET
• 24 P SWITCH
• 1500 UPS
REX A
CR
• Remove
• Decoder
• 32 Monitor
• Wall mount
• Mini Tower UPS
• Decoder
• 32"MTR Wall mount
• Mini Tower UPS
• VSS Workstation
• 1500 Tower UPS
• Rack
• VSS NVR
• 24P Switch
• 2200 Rack UPS
• Extended Battery
CAM 13
TVR
DB
SR
LEGEND
DB: Duress Button PIR: Passive Infrared Sensor DR: Door Release Button CR: Card Reader DC: Door Contact EA: Exit Alarm TVR: Wireless Transceiver PTE: Push To Exit Button REX: Request To Exit Sensor KP: Alarm Keypad DI: Door Intercom Station MS: Master Intercom Station SR: Siren STB: Strobe
DC
Door # 1
TVR DB
DC
Door # 9
STB
STB
STB
• Decoder
• 32"MTR Wall mount
• Mini Tower UPS
PIR
PIRPIR
PIRPIR
PIRPIR
PIRPIR
PIRPIR
PIRPIR
PIRPIR
PIRPIR
Serial #
Model #
Switch 3300 TM
SuperStack3
6x
18x
1x
13x
12x
24x
7x
19x
1 2 3 4 5 6
13 14 15 16 17 18
13 14 15 16 17 18
1 2 3 4 5 6
7 8 9 10 11 12
19 20 21 22 23 24
19 20 21 22 23 24
7 8 9 10 11 12
Packet
Status
Packet
Status
1 2
7 8
5 6
3 4
10BAST-T/100BASE-TX
green = enabled, link OK flashing green = disabled, linkOK
1000BASE-T Unit
Power/Self Test
Test I
O www.apcc.com
Smart-UPS
1 5 0 0
Smart-UPS
1 5 0 0
Test I
O w w w .ap cc .c om
Test I
O www.apcc.com
Smart-UPS
1 5 0 0
Test I
O www.apcc.com
Smart-UPS
1 5 0 0
Test I
O www.apcc.com
Smart-UPS
1 5 0 0
Smart-UPS
1 5 0 0
Test I
O w w w .ap cc .c om
Switch 3300 TM
SuperStack3
6x
18x
1x
13x
12x
24x
7x
19x
1 2 3 4 5 6
13 14 15 16 17 18
13 14 15 16 17 18
1 2 3 4 5 6
7 8 9 10 11 12
19 20 21 22 23 24
19 20 21 22 23 24
7 8 9 10 11 12
Packet
Status
Packet
Status
1 2
7 8
5 6
3 4
10BAST-T/100BASE-TX
green = enabled, link OK flashing green = disabled, linkOK
1000BASE-T Unit
Power/Self Test
Smart-UPS
1 5 0 0
Test I
O w w w .ap cc .c om
Switch 3300 TM
SuperStack3
6x
18x
1x
13x
12x
24x
7x
19x
1 2 3 4 5 6
13 14 15 16 17 18
13 14 15 16 17 18
1 2 3 4 5 6
7 8 9 10 11 12
19 20 21 22 23 24
19 20 21 22 23 24
7 8 9 10 11 12
Packet
Status
Packet
Status
1 2
7 8
5 6
3 4
10BAST-T/100BASE-TX
green = enabled, link OK flashing green = disabled, linkOK
1000BASE-T Unit
Power/Self Test
Smart-UPS
6 2 0 www.apcc.com
32" Decoder
Testing Room 134
Smart-UPS
6 2 0 www.apcc.com
43" Decoder
HQ
Room 134
S m a rt
-U P
S
T es t I O w w w .a p cc
.c o m
First Floor Room 178A
Second Floor Room 231
Second Floor Room 223
Smart-UPS
6 2 0 www.apcc.com
32" Decoder
MEDICAL
Room 267
Smart-UPS
6 2 0 www.apcc.com
43" Decoder
CONTROL DESK
Room 210
Second Floor Room 214
C
C
C
C
Medical
HQ
Testing
Operations
Door Intercom
MX8
MX8
Master Station
Patch Panel Cable Mgnt Bay Switch
NVR
2KVA UPS (1)
EBT (4)
32"
Patch Panel Cable Mgnt Bay Switch
1KVA UPS (1)
Patch Panel Cable Mgnt Bay Switch
1KVA UPS (1)
| Boise 2025.vsdx |
| Page-1 |
| Page-2 |
| Page-3 |
File details come from the government source that posted it. Updated .