Hydac Filter Specifications.pdf

PDF 378 KB Posted

Attached to
4410--Filter Boiler Reheat System
Solicitation number
36C24625Q0426
Issued by

About this file

This document contains technical specifications and configuration details for the Schroeder Industries AutoFilt RF3-2.5 Backflushing Filter system. The specifications outline a filter system with a flow range of 1760-2640 gpm (6670-10,000 L/min), working pressure of 150 psi (10 bar), and maximum working temperature of 194°F (90°C).

The document provides detailed dimensional drawings, installation configurations, and a model number selection guide for ordering. Key specifications include a 10" ANSI flange size, filter area of 1940 in², 6 filter elements, and backflush volume options of 17 gallons per cycle for Electric-Pneumatic Controls or 85 gallons per cycle for All Electric Controls. The system weighs 990 lbs empty and has a housing volume of 50 gallons. The specifications include pressure drop flow curves and multiple configuration options for housing materials, control types, and element sets ranging from 25 micron to 3000 micron filtration ratings.

View the file

Other files

File Type Posted
Supply eCMS Line Item Template.xlsx XLSX spreadsheet
36C24625Q0426.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCHROEDER INDUSTRIES | PROCESS FILTRATION20

1760-2640 gpm

6670-10,000 L/min

150 psi 10 bar

RF3-2.5 Backflushing Filter AutoFilt® RF3

Specifications

Pressure Drop

Information Based on Flow Rate and Viscosity

NOTES:

1. Metric di men sions in ( ).

2. Drawings may change without notice. Contact factory for certified drawings.

57.11

69.31

47.11

6.7

.22

.70

69.31

SNOITARUGIFNOC EGNALF TELTUO

TELNI

.54

00.6

.32

.79

.01 43

8.7

8.7

35.7

°94

17.

SECALP )3(

Flange Size: 10"ANSI

Flow Range: 1760-2640 gpm (6670-10,000 L/min)

Working Pressure: 150 psi (10 bar)

Max. Working Temperature: 194°F (90°C)

Empty Weight: 990 lbs. (450 kg)

Housing Volume: 50 gallons (190 L)

Filter Area: 1940 in.2 (12,500 cm2)

No. of Filter Elements 6

Backflush Flange Size: 2"ANSI

Backflush Volume: 17 gallons (65 L/cycle) Electric-Pneumatic Controls (EPT) 85 gallons (325 L/cycle) All Electric Controls (EU) sevruC wolF 3FR

5.2-3FR

00001

000001

55.445.335.225.115.00 )disp( pord erusserP

Fl ow

R at e (g pm

= )ylppa snoitidnoc( etar wolf xam

:etoN sgnitar noitartlif mµ0003 - mµ001 rof era sevruc esehT rof %03 yb sesaercni pord erusserp ehT .snoitidnoc naelc rednu roF .8 hguorht 0-3FR sezis gnisu nehw noitartlif mµ05 - mµ52 .sgnitar noitartlif lla ot seilppa nwohs evruc eht ,C-3FR

RF3-C

RF3-0

RF3-1

RF3-2

RF3-2.5

RF3-3

RF3-4

RF3-5

RF3-6

RF3-7

RF3-8

RF5

RF7

RF10

RF4

RF4-1

RF4-2

RF12

BTU

ATF

PLF1

PVD

SCHROEDER INDUSTRIES | PROCESS FILTRATION

Filter Model Number Selection

Backflushing Filter AutoFilt® RF3

RF3-2.5

RF3-2.5

EPT = Electric pneumatic cycle control, ∆p dependent

EU = Electric control, ∆p dependent

PT = Pneumatic cyclic control, ∆p dependent

PTZ = Pneumatic cyclic timed control

7 = 3X415V/N/PE 60Hz

8 = 3X460V/X/PE 60Hz

B = 3X575V/X/PE 60Hz

E = 1X230V/N/PE 60Hz

F = 1X110V/N/PE 60Hz

BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11

Vessel Certification

Omit = Standard Version

ASME = ASME Version

Size of Element Set

2.5

Modification Number

2 = Latest version supplied by factory

Shut-Off Valve Material

N = Standard Steel

E = Stainless Steel

Housing Material and Coating

N = Standard Steel 1.0038, outside primed

NM = Standard Steel 1.0038, outside primed, inside metallogal painted

NG =Standard Steel 1.0038, outside primed, inside rubber coated

E = Stainless Steel 1.4571

A = With ANSI-flanged, add. A at the end

Drive Control / Connecting Voltage

Filter Series

Filter Size

RF3 2.5

How to Build a Valid Model Number for a RF3:

Example: NOTE: One option per box

BOX 1 BOX 2 BOX 3 BOX 4 BOX 5

BOX 6 BOX 7 BOX 8 BOX 9

Flange Position

1 = Filter outlet opposite filter inlet (standard)

2 = Filter outlet offset 90˚ clockwise to standard

3 = Filter outlet offset by 180˚ clockwise to standard

4 = Filter outlet offset by 270˚ clockwise to standard

BOX 10 BOX 11

RF3 ASME2.5KS1000235NNGEPT82.5 = RF3-2.5-EPT8-NG-N-5-3-2

/KS1000-2.5-ASME

Element Set

KD25 = Conical SuperMesh™

KD40 = Conical SuperMesh™

KS50 = Conical Slotted Tubes

KS100 = Conical Slotted Tubes

KS200 = Conical Slotted Tubes

KS300 = Conical Slotted Tubes

KS400 = Conical Slotted Tubes

KS500 = Conical Slotted Tubes

KS1000 = Conical Slotted Tubes

KS1500 = Conical Slotted Tubes

KS2000 = Conical Slotted Tubes

KS2500 = Conical Slotted Tubes

KS3000 = Conical Slotted Tubes

NOTES:

Box 3. Needs to have control type and voltage selected

ex. EPT8.

Box 4. can contain two options ex. NMA.

note.IfANSIflanges
arenotspecified

DIN style will be provided.

Differential Pressure Gauge

1 = Pressure Chamber, Aluminum 3.258302

2 = Pressure Chamber, Stainless Steel 1.4305

3 = With Chemical Seal Stainless Steel 316TI

5 = HDA 4700

Stainless Steel

6 = HDA 4300 Duplex Stainless Steel

BOX 1 BOX 2 BOX 3 BOX 4 BOX 5 BOX 6 BOX 7 BOX 8 BOX 9 BOX 10 BOX 11

RF3 2.5