This is a Request for Quote (RFQ) issued by the Defense Health Agency for microbiology testing equipment and services at Keesler Medical Center, Keesler AFB, Mississippi. The requirement is for one automated system for microbial identification and antimicrobial susceptibility testing, and one automated microbial detection system for monitoring microorganisms in blood and sterile body fluid samples. The period of performance includes a base year (April 1, 2025 - March 31, 2026) and four one-year options extending through March 31, 2030.
The contractor must provide all equipment, reagents, maintenance, and services on either an equipment rental/lease basis or Cost Per Reportable Result basis. Key requirements include FDA-approved equipment, bi-directional interface with MHS Genesis, Authorization to Operate (ATO) approval, and estimated annual test quantities including 900 bacterial gram-negative identifications, 500 gram-positive identifications, and 1,500 each of aerobic and anaerobic monitoring bottles. The contractor must provide initial training for two key operators, ongoing annual training, 24/7 technical support with 24-hour response time, and 4-hour on-site response if both analyzers are down. Offers are due by January 2, 2025 at 1:00 PM Central Time, with a question deadline of December 19, 2024. Award will be made using lowest price technically acceptable (LPTA) criteria.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 3 Pricing_Microbiology Amend 0002.xlsx | XLSX spreadsheet | |
| HT940825R0004 0002.pdf | ||
| HT940825R0004 0001.pdf | ||
| Attachment 2_CyberLOG - MDERA.pdf | ||
| Attachment 3 Pricing_Microbiology.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE ADDENDUM
(No Collect Calls)
HT940825R0004 13-Dec-2024
b. TELEPHONE NUMBER
210-269-4696
8. OFFER DUE DATE/LOCAL TIME
01:00 PM 02 Jan 2025
5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
STANDARD FORM 1449 (REV. 2/2012)
Prescribed by GSA – FAR (48 CFR) 53.212
(TYPE OR PRINT)
(SIGNATURE OF CONTRACTING OFFICER)
ADDENDA ARE
26. TOTAL AWARD AMOUNT (For Gov t. Use Only )
23.
CODE 10. THIS ACQUISITION IS
SUCH ADDRESS IN OFFER
17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT
BELOW IS CHECKED
TELEPHONE NO.
HT94089. ISSUED BY
18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK
7. FOR SOLICITATION
INFORMATION CALL:
a. NAME
DAVID K ERPELDING
2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER
(TYPE OR PRINT)
30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER
30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA
0 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.
25. ACCOUNTING AND APPROPRIATION DATA
1. REQUISITION NUMBER
20.
ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.
OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
ARE NOT ATTACHED
27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED
(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE
SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:
. YOUR OFFER ON SOLICITATION
28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN
% FOR:SET ASIDE:UNRESTRICTED ORX
SMALL BUSINESS
17a.CONTRACTOR/ CODE FACILITY
OFFEROR CODE
DHA CONTRACTING OFFICE SA HT9408
7800 W IH-10
STE 235
SAN ANTONIO TX 78230
18a. PAYMENT WILL BE MADE BY CODE
RATED ORDER UNDER
DPAS (15 CFR 700)
13a. THIS CONTRACT IS A
13b. RATING
CODE15. DELIVER TO CODE HT1123 16. ADMINISTERED BY
12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-
TION UNLESS BLOCK IS
MARKED
SEE SCHEDULE
14. METHOD OF SOLICITATION
RFQ IFB RFPX
81ST MDG SGL - MM
LEN VAN SITTERT
CP 338 377 6365 301 FISHER ST STE 101
KEESLER AFB MS 39534-2519
TEL: 228-376-5000 FAX:
FAX:
TEL: SERVICE-DISABLED
VETERAN-OWNED
SMALL BUSINESS
8(A)
HUBZONE SMALL
BUSINESS
SIZE STANDARD:
1,250
NAICS:
325413
X
OFFER DATED
29. AWARD OF CONTRACT: REF.
DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY
COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND
EMAIL:
TEL:
31c. DATE SIGNED
SEE SCHEDULE
SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT
24.22.21.19.
WOMEN-OWNED SMALL BUSINESS (WOSB)
ELIGIBLE UNDER THE WOMEN-OWNED
SMALL BUSINESS PROGRAM
EDWOSB
32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE
SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS
(CONTINUED)
PAGE 2 OF61
ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________
32a. QUANTITY IN COLUMN 21 HAS BEEN
RECEIVED INSPECTED
32b. SIGNATURE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT
REPRESENTATIVE
32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE
37. CHECK NUMBER
FINALPARTIALCOMPLETE
36. PAYMENT35. AMOUNT VERIFIED
CORRECT FOR
34. VOUCHER NUMBER
FINAL
33. SHIP NUMBER
PARTIAL
38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY
41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT 41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE
42a. RECEIVED BY (Print)
42b. RECEIVED AT (Location)
42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS
STANDARD FORM 1449 (REV. 2/2012) BACK
Prescribed by GSA – FAR (48 CFR) 53.212
AUTHORIZED FOR LOCAL REPRODUCTION
PREVIOUS EDITION IS NOT USABLE
SEE SCHEDULE
20.
SCHEDULE OF SUPPLIES/ SERVICES
21.
QUANTITY UNIT
22. 23.
UNIT PRICE
24.
AMOUNT
19.
ITEM NO.
Section SF 1449 - CONTINUATION SHEET
STATEMENT OF OBJECTIVES
STATEMENT OF OBJECTIVES
The Keesler Medical Center Clinical Laboratory at Keesler AFB, Mississippi requires one (1) automated system that performs microbial identification and antimicrobial susceptibility testing and one (1) automated microbial detection system for the monitoring of the presence or absence of microorganisms from both blood and other sterile body fluid samples. The successful offeror shall furnish all equipment, reagents, and any necessary services (e.g., maintenance of furnished equipment) to Keesler Medical Center, Keesler AFB, MS for the purpose of Microbiology testing. This requirement will be met via equipment rental/lease or on a Cost Per Reportable Result (CPRR) basis. The requirement must include equipment and reagents to perform the following number of tests per year:
All equipment and reagents shall be supplied and serviced through the Contractor to include all parts, equipment, supplies, and other services required to ensure Keesler Medical Center is able to meet its objectives as listed herein.
Equipment and associated peripherals must be delivered in such a time that installation, set-up, and validations are completed and approved by the Laboratory Director to begin patient testing by the start of the base year of the period of performance. In addition, an approved authority to operate (ATO) is required prior to use and any subsequent billing. ATO approval must be maintained and valid through the life of the contract.
Period of Performance:
Base: 1 April 2025 – 31 March 2026 Option 1: 1 April 2026 – 31 March 2027 Option 2: 1 April 2027 – 31 March 2028 Option 3: 1 April 2028 – 31 March 2029 Option 4: 1 April 2029 – 31 March 2030
1. Authorization to Operate (ATO) Subfactor 1A)
Required capability Estimated test quantity per year Bacterial Gram-negative identification 900 Bacterial Gram-positive identification 500 Neisseria/Haemophilus identification 120 Anaerobic bacterial identification 100 Bacterial Gram-negative susceptibility testing 1,500 Bacterial Gram-positive susceptibility testing 1,300 Bacterial Streptococcus susceptibility testing 120 Aerobic bottles for microorganism monitoring 1,500 Anaerobic bottles for microorganism monitoring 1,500 Pediatric bottles for microorganism monitoring 600
1.1. Analyzers must have a bi-directional interface that can connect to and be fully interoperable with the laboratory information system (LIS) Military Health System Genesis, as listed on CSTAR https://info.health.mil/apps/HIT/cstar/Pages/Systems.aspx. The Contractor must have an approved ATO is required prior to use and any subsequent billing, and approval must be maintained and valid through the life of the contract.
1.2 Middleware must have an approved ATO prior to use and any subsequent billing, and approval must be maintained and valid through the life of the contract.
1.3. Each interface must allow for recognition and interpretation of MHS Genesis generated bar-code labels on all sample tube types. Connectivity between the Contractor instrument systems and middleware to each LIS will be required at varying times during the contracted period of performance. Location: 81MDTS/SGQC Clinical Laboratory, Keesler Medical Center, Keesler Air Force Base, MS.
2. Instruments/Equipment and Reagents/Consumables (Subfactor 1B)
2.1. Instruments/Equipment
2.1.1. The new equipment is to be in place and fully operational, i.e. ready for patient testing, no later than the start of the base year of the period of performance. The on-site installation process should begin no less than 90 days after award, but as soon as necessary to ensure equipment is fully operational on first day of the base year of the period of performance.
2.1.2. Instrument must be Food and Drug Administration (FDA) approved for microbial identification and antimicrobial susceptibility testing. Testing must include confirmatory identification and minimum inhibitory concentration of microorganisms. The testing must also be current with the Clinical Laboratory Standards Institute (CLSI) breakpoints through 2026.
2.1.3. Must supply benchtop for instrument to fit in a space approximately 28” wide by 27” deep with the instrument approximately 24” in height.
2.1.4. Instrument must use existing 100/120 VAC (50-60 HZ) power capability that is within 5’ of the installation location.
2.1.5. The instrument must have the capability of sample and reagent bar-code reading.
2.1.6. The instrument must have automatic dilution of patient samples, so that no manual predilutions are necessary. The instrument must have the ability to read panels manually.
2.1.7. The Contractor will include all equipment and supplies capable of comprehensive microbial identification and susceptibility testing to include Gram negative, Gram positive, aerobic, and anaerobic bacteria for the estimated annual quantities in the table below.
Required capability Estimated test quantity per year Bacterial Gram-negative identification 900 Bacterial Gram-positive identification 500 Neisseria/Haemophilus identification 120 Anaerobic bacterial identification 100 Bacterial Gram-negative susceptibility testing 1,500 Bacterial Gram-positive susceptibility testing 1,300 Bacterial Streptococcus susceptibility testing 120
2.1.8. Instrument and reagents must have the ability to determine inducible clindamycin resistance, extended-spectrum beta-lactamase producing organisms and methicillin resistant Staphylococcus aureus.
2.1.9. Instrument and reagents must have the ability to produce minimum inhibitory concentration results, following CLSI recommendations and breakpoints through 2026, for the following antimicrobials and organisms with the opportunity to expand to test for additional antimicrobials as deemed necessary by the Keesler Medical Center Antimicrobial Stewardship Committee. Expansion will include validation and will be at no cost to the government:
Gram Negative Organisms Ampicillin Ampicillin/Sulbactam Cefazolin Piperacillin/Tazobactam Ceftazidime Ceftriaxone Cefepime Aztreonam Ertapenem Meropenem Amikacin Gentamicin Ciprofloxacin Tigecycline Nitrofurantoin Trimethoprim/Sulfamethoxazole
Gram Positive Organisms Ampicillin Ciprofloxacin Clindamycin Daptomycin Doxycycline Erythromycin Gentamicin Gentamicin High Level
(synergy) Levofloxacin Linezolid Moxifloxacin Nitrofurantoin Oxacillin Rifampicin Tetracycline Streptomycin High Level
(synergy) Tigecycline Vancomycin Trimethoprim/Sulfamethoxazole
Streptococcus sp.
Ampicillin Benzylpenicillin Cefotaxime Ceftriaxone Clindamycin Erythromycin Levofloxacin Linezolid Moxifloxacin Tetracyclines Tigecycline Trimethoprim/Sulfamethoxazole Vancomycin
2.1.10. Contractor must perform periodic instrument preventative maintenance and calibration along with 24/7 technical support and service and repairs to keep instrumentation operational.
Response to service needs provided not later than 24 hours and resolution not later than 48 hours (local service personnel preferred) from report of service need or receipt of replacement parts within standard business hours (5 days, 8 hours).
2.2. Microbial detection system for the monitoring of the presence or absence of microorganisms.
2.2.1. Instrument must be Food and Drug Administration (FDA) approved for the monitoring of the presence or absence of microorganisms from both blood and other sterile body fluid samples.
2.2.2. The analyzers must meet all necessary power and waste requirements as dictated by the current laboratory workspace. Instrument must fit in a space approximately 48” wide by 36” deep for the blood culture platform. This equipment is 12” from an outlet. The microbial identification and susceptibility testing platform must fit into a space of 60” wide by 36” deep, with approximately 40” from two (2) wall outlets. For a benchtop instrument, a workbench must be provided.
2.2.3. Instrument must use existing 100/120 VAC (50-60 HZ) power capability.
2.2.4. Instrument must have minimum capacity to monitor 120 bottles at one time.
2.2.5. Bottles must be plastic and be FDA approved for the detection of microorganisms in blood and other sterile body fluids to include synovial fluid for the estimated quantities listed in the table below:
Required capability Estimated test quantity per year Aerobic bottles for microorganism monitoring 1,500 Anaerobic bottles for microorganism monitoring 1,500 Pediatric bottles for microorganism monitoring 600
2.2.6. Instrument must have the capability to interface and be fully interoperable with the laboratory information system (LIS), MHS Genesis, and must have an approved authorization to operate (ATO) on the DHA network as listed on CSTAR (https://info.health.mil/apps/HIT/cstar/Pages/Systems.aspx). An approved ATO is required prior to use and any subsequent billing and must be maintained and valid through the life of the contract.
2.2.8. Usage of all computer components, printers and accessories needed to operate instrument and middleware must be interoperable with MHS Genesis. Middleware must have an approved ATO prior to use and any subsequent billing. ATO approval must be maintained and valid through the life of the contract.
2.2.9. Each interface must allow for recognition and interpretation of MHS Genesis generated bar-code labels on all sample container types. Connectivity between the Contractor’s instrument systems and middleware to each LIS will be required at varying times during the contracted period of performance. Location: 81MDTS/SGQC Clinical Laboratory, Keesler Medical Center, Keesler Air Force Base, MS.
3. Service and Maintenance (Subfactor 1C). The Contractor shall meet the following service and maintenance requirements:
3.1 Contractor must perform periodic instrument preventative maintenance and calibration along with 24/7 technical support and service and repairs to keep instrumentation operational.
Response to service needs provided not later than 24 hours and resolution not later than 48 hours (local service personnel preferred) from report of service need or receipt of replacement parts within standard business hours (5 days, 8 hours). If both analyzers are down, service personnel must be on-site within 4 hours of initial notification.
3.2 Contractor shall provide product service and support to include updates to operational software throughout the life cycle of the equipment.
3.3. Any service technician provided by the Contractor shall adhere to all required reporting procedures for Keesler Air Force Base.
4. Training (Subfactor 1D) Instrument training.
4.1. Each Contractor will provide the training for each individual piece of equipment, software, middleware and accessories at no additional cost to the Government:
4.1.1. Initial training (upon award) for two (2) key operators including lodging (hotel), per diem, and travel (airfare, local transportation) expenses to/from Keesler AFB, hotel, and training location (offsite location). Additional training, upon request, for one operator per year per instrument (lodging (hotel), per diem, and travel (airfare, local transportation) expenses included to/from Keesler AFB, hotel, and training location). Alternative training delivery (i.e., distance training), if determined by the Government customer to be of equivalent quality, may be entertained in lieu of offsite, in-person training for non-initial training.
4.1.2 All training shall include basic analyzer operation for each piece of equipment, troubleshooting procedures, performance of operator level periodic preventive maintenance procedures, and the use of any data management/quality control software.
5. Delivery and Installation (Subfactor 1E).
5.1. All systems shall be delivered to the appropriate location indicated below.
Keesler Medical Center Clinical Laboratory 81 MDTS/SQQC 301 Fisher St Keesler AFB, MS 39534
5.2. The Contractor shall assign a Project Manager to oversee all operations required for successful implementation and execution of the requirement.
5.3. No less than 10 calendar days from the contract award, Contractor shall coordinate and conduct a post-award site visit for the purpose of coordinating the schedule for equipment installation and validations.
5.3.1. The Project Manager will provide a timeline identifying critical points in the delivery/installation phase, wherein Day 0 = Notice of Award.
5.3.2. Contractor must include Utility layout required and CAD drawing with detailed analyzer layout with proposal, including facility modifications proposed if applicable. See attachment 1 for current floorplan.
5.4. Contract must include instrument installation, set-up, validation with current breakpoints for 2026, supplies, and labor. The on-site installation process should begin no less than 90 days after award, but as soon as necessary to ensure equipment is fully operational on first day of the base year of the period of performance. This includes all correlation, precision, linearity, normal range, and any other required validation studies by a Contractor provided Clinical Application Specialist. The Clinical Application Specialist should possess a thorough knowledge of method validation/verification and, where applicable, is familiar with the use of clinical laboratory statistical evaluation software (e.g. EP Evaluator®). The assigned Clinical Application Specialist will be responsible for the entire method validation to the standards of the acting medical director. The completed validation studies and raw data must be provided to the Microbiology management staff electronically and, in a binder, at least 3 weeks prior to analyzer functionality.
5.5. Method validation/verification will be conducted in accordance with procedures as required by the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations and the College of American Pathologists (CAP) requirements.
5.6. The method validation/verification will be completed and approved by the Laboratory Director prior to reporting of patient results. Payment for services will not begin until the analyzer system has been approved for reporting of patient results.
5.7. All instrument reagents, calibrators, linearity materials and other required reagents/materials used in the method validation/verification study will be provided by the Contractor at no additional cost to the Government. Assay lots will be quality checked upon delivery. Contractor’s customer samples may also be used. These materials will not be used in the analysis of specimens for patient care.
5.8. The Contractor shall relocate/revalidate any instrument if requested by the Government at no additional cost. This includes any location within the Keesler AFB Medical Center.
HT940825R0004
Attachment 1
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 1 Job
Microbiology - Cost- er-
FFP
Microbiology equipment to include equipment, maintenance, supplies/reagents.
One (1) automated system that performs microbial identification and antimicrobial susceptibility testing and one (1) automated microbial detection system for the monitoring of the presence or absence of microorganisms from both blood and other sterile body fluid samples. Met via a Cost Per Test.
Service coverage for instruments: Periodic instrument preventative maintenance and calibration along with 24/7 technical support and service and repairs to keep instrumentation operational is included at no additional cost. Response to service needs provided not later than 24 hours and resolution not later than 48 hours from report of service need or receipt of replacement parts within standard business hours (5 days, 8 hours). If both analyzers are down, service personnel must be on-site within 4 hours of initial notification.
Initial training for two key operators and additional training, upon request, for one operator per year per instrument (on-site, off-site, e-Learning, and Virtual Instructor Led Training) is included at no additional cost.
Per monthly test quantity:
Bacterial Gram-negative identification - 75 Bacterial Gram-positive identification – 42 Neisseria/Haemophilus identification - 10 Anaerobic bacterial identification – 8 Yeast identification – 8.3 Bacterial Gram-negative susceptibility testing - 125 Bacterial Gram-positive susceptibility testing – 108 Bacterial Streptococcus susceptibility testing - 10 Yeast susceptibility testing – 8.3 Not to exceed the yearly test quantity located at paragraph 2.1.7 in the Statement of Objectives.
The Government will pay actual Cost-per- , not to exceed the estimated yearly test quantities.
Base Period of Performance: 01 APR 2025 - 31 MAR 2026
NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent.
FOB: Destination
NET AMT
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
Equipment Delivery and Install
FFP
From contract award date to 31 March 2025, there shall be no invoicing. This period is strictly to notify the vendor of award allowing time for delivery of equipment, installation, validation and proper Authorization to Operate approval by vendor prior to the base period of performance start date of 1 April 2025.
FOB: Destination
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
1001 1 Job OPTION Microbiology -
FFP
Microbiology equipment to include equipment, maintenance, supplies/reagents.
One (1) automated system that performs microbial identification and antimicrobial susceptibility testing and one (1) automated microbial detection system for the monitoring of the presence or absence of microorganisms from both blood and other sterile body fluid samples. Met via a Cost Per Test.
Service coverage for instruments: Periodic instrument preventative maintenance and calibration along with 24/7 technical support and service and repairs to keep instrumentation operational is included at no additional cost. Response to service needs provided not later than 24 hours and resolution not later than 48 hours from report of service need or receipt of replacement parts within standard business hours (5 days, 8 hours). If both analyzers are down, service personnel must be on-site within 4 hours of initial notification.
Initial training for two key operators and additional training, upon request, for one operator per year per instrument (on-site, off-site, e-Learning, and Virtual Instructor Led Training) is included at no additional cost.
Per monthly test quantity:
Bacterial Gram-negative identification - 75 Bacterial Gram-positive identification – 42 Neisseria/Haemophilus identification - 10 Anaerobic bacterial identification – 8 Yeast identification – 8.3 Bacterial Gram-negative susceptibility testing - 125 Bacterial Gram-positive susceptibility testing – 108 Bacterial Streptococcus susceptibility testing - 10 Yeast susceptibility testing – 8.3 Not to exceed the yearly test quantity located at paragraph 2.1.7 in the Statement of Objectives.
The Government will pay actual , not to exceed the estimated yearly test quantities.
Base Period of Performance: 01 APR 2026 - 31 MAR 2027
NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent. FOB:
Destination
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
2001 1 Job OPTION Microbiology -
FFP
Microbiology equipment to include equipment, maintenance, supplies/reagents.
One (1) automated system that performs microbial identification and antimicrobial susceptibility testing and one (1) automated microbial detection system for the monitoring of the presence or absence of microorganisms from both blood and other sterile body fluid samples. Met via a Cost Per Test.
Service coverage for instruments: Periodic instrument preventative maintenance and calibration along with 24/7 technical support and service and repairs to keep instrumentation operational is included at no additional cost. Response to service needs provided not later than 24 hours and resolution not later than 48 hours from report of service need or receipt of replacement parts within standard business hours (5 days, 8 hours). If both analyzers are down, service personnel must be on-site within 4 hours of initial notification.
Initial training for two key operators and additional training, upon request, for one operator per year per instrument (on-site, off-site, e-Learning, and Virtual Instructor Led Training) is included at no additional cost.
Per monthly test quantity:
Bacterial Gram-negative identification - 75 Bacterial Gram-positive identification – 42 Neisseria/Haemophilus identification - 10 Anaerobic bacterial identification – 8 Yeast identification – 8.3 Bacterial Gram-negative susceptibility testing - 125 Bacterial Gram-positive susceptibility testing – 108 Bacterial Streptococcus susceptibility testing - 10 Yeast susceptibility testing – 8.3 Not to exceed the yearly test quantity located at paragraph 2.1.7 in the Statement of Objectives.
The Government will pay actual not to exceed the estimated yearly test quantities.
Base Period of Performance: 01 APR 2027 - 31 MAR 2028
NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent. FOB:
Destination
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
3001 1 Job OPTION Microbiology -
FFP
Microbiology equipment to include equipment, maintenance, supplies/reagents.
One (1) automated system that performs microbial identification and antimicrobial susceptibility testing and one (1) automated microbial detection system for the monitoring of the presence or absence of microorganisms from both blood and other sterile body fluid samples. Met via a Cost Per Test.
Service coverage for instruments: Periodic instrument preventative maintenance and calibration along with 24/7 technical support and service and repairs to keep instrumentation operational is included at no additional cost. Response to service needs provided not later than 24 hours and resolution not later than 48 hours from report of service need or receipt of replacement parts within standard business hours (5 days, 8 hours). If both analyzers are down, service personnel must be on-site within 4 hours of initial notification.
Initial training for two key operators and additional training, upon request, for one operator per year per instrument (on-site, off-site, e-Learning, and Virtual Instructor Led Training) is included at no additional cost.
Per monthly test quantity:
Bacterial Gram-negative identification - 75 Bacterial Gram-positive identification – 42 Neisseria/Haemophilus identification - 10 Anaerobic bacterial identification – 8 Yeast identification – 8.3 Bacterial Gram-negative susceptibility testing - 125 Bacterial Gram-positive susceptibility testing – 108 Bacterial Streptococcus susceptibility testing - 10 Yeast susceptibility testing – 8.3 Not to exceed the yearly test quantity located at paragraph 2.1.7 in the Statement of Objectives.
The Government will pay actual not to exceed the estimated yearly test quantities.
Base Period of Performance: 01 APR 2028 - 31 MAR 2029
NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent. FOB:
Destination
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
4001 1 Job OPTION Microbiology -
FFP
Microbiology equipment to include equipment, maintenance, supplies/reagents.
One (1) automated system that performs microbial identification and antimicrobial susceptibility testing and one (1) automated microbial detection system for the monitoring of the presence or absence of microorganisms from both blood and other sterile body fluid samples. Met via a Cost Per Test.
Service coverage for instruments: Periodic instrument preventative maintenance and calibration along with 24/7 technical support and service and repairs to keep instrumentation operational is included at no additional cost. Response to service needs provided not later than 24 hours and resolution not later than 48 hours from report of service need or receipt of replacement parts within standard business hours (5 days, 8 hours). If both analyzers are down, service personnel must be on-site within 4 hours of initial notification.
Initial training for two key operators and additional training, upon request, for one operator per year per instrument (on-site, off-site, e-Learning, and Virtual Instructor Led Training) is included at no additional cost.
Per monthly test quantity:
Bacterial Gram-negative identification - 75 Bacterial Gram-positive identification – 42 Neisseria/Haemophilus identification - 10 Anaerobic bacterial identification – 8 Yeast identification – 8.3 Bacterial Gram-negative susceptibility testing - 125 Bacterial Gram-positive susceptibility testing – 108 Bacterial Streptococcus susceptibility testing - 10 Yeast susceptibility testing – 8.3 Not to exceed the yearly test quantity located at paragraph 2.1.7 in the Statement of Objectives.
The Government will pay actual not to exceed the estimated yearly test quantities.
Base Period of Performance: 01 APR 2029 - 31 MAR 2030
NOTE: The requirements in DFARS 252.211-7003, Item Identification and Valuation, are applicable for this line item. The contractor shall provide DoD unique identification or a DoD recognized unique identification equivalent. FOB:
Destination
INSPECTION AND ACCEPTANCE TERMS
Supplies/services will be inspected/accepted at:
CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY
0001 Destination Government Destination Government 0002 N/A N/A N/A Government 1001 Destination Government Destination Government 2001 Destination Government Destination Government 3001 Destination Government Destination Government 4001 Destination Government Destination Government
DELIVERY INFORMATION
CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
0001 31-MAR-2026 1 81ST MDG SGL - MM
LEN VAN SITTERT
CP 338 377 6365 301 FISHER ST
STE 101
KEESLER AFB MS 39534-2519
228-376-5000 FOB: Destination
HT1123
0002 31-MAR-2026 (SAME AS PREVIOUS LOCATION)
FOB: Destination
HT1123
1001 31-MAR-2027 1 (SAME AS PREVIOUS LOCATION)
FOB: Destination
HT1123
2001 31-MAR-2028 1 (SAME AS PREVIOUS LOCATION)
FOB: Destination
HT1123
3001 31-MAR-2029 1 (SAME AS PREVIOUS LOCATION)
FOB: Destination
HT1123
4001 31-MAR-2030 1 (SAME AS PREVIOUS LOCATION)
FOB: Destination
HT1123
CLAUSES INCORPORATED BY REFERENCE
52.203-3 Gratuities APR 1984 52.203-6 Alt I Restrictions On Subcontractor Sales To The Government
(JUN 2020) -- Alternate I
NOV 2021
52.203-12 Limitation On Payments To Influence Certain Federal Transactions
JUN 2020
52.204-7 System for Award Management NOV 2024 52.204-10 Reporting Executive Compensation and First-Tier
Subcontract Awards
JUN 2020
52.204-13 System for Award Management Maintenance OCT 2018 52.204-16 Commercial and Government Entity Code Reporting AUG 2020 52.204-18 Commercial and Government Entity Code Maintenance AUG 2020 52.204-21 Basic Safeguarding of Covered Contractor Information
Systems
NOV 2021
52.204-27 Prohibition on a ByteDance Covered Application JUN 2023 52.207-4 Economic Purchase Quantity-Supplies AUG 1987 52.209-6 Protecting the Government's Interest When Subcontracting
With Contractors Debarred, Suspended, or Proposed for Debarment
NOV 2021
52.209-7 Information Regarding Responsibility Matters OCT 2018 52.209-9 Updates of Publicly Available Information Regarding
Responsibility Matters
OCT 2018
52.209-10 Prohibition on Contracting With Inverted Domestic Corporations
NOV 2015
52.212-4 Contract Terms and Conditions--Commercial Products and Commercial Services
NOV 2023
52.214-34 Submission Of Offers In The English Language APR 1991 52.219-4 Notice of Price Evaluation Preference for HUBZone Small
Business Concerns
OCT 2022
52.222-22 Previous Contracts And Compliance Reports FEB 1999 52.222-25 Affirmative Action Compliance APR 1984 52.223-10 Waste Reduction Program MAY 2024 52.225-13 Restrictions on Certain Foreign Purchases FEB 2021 52.229-11 Tax on Certain Foreign Procurements--Notice and
Representation
JUN 2020
52.232-18 Availability Of Funds APR 1984 52.232-33 Payment by Electronic Funds Transfer--System for Award
Management
OCT 2018
52.232-39 Unenforceability of Unauthorized Obligations JUN 2013 52.233-3 Protest After Award AUG 1996 52.233-4 Applicable Law for Breach of Contract Claim OCT 2004 52.242-13 Bankruptcy JUL 1995 52.246-16 Responsibility For Supplies APR 1984 252.203-7000 Requirements Relating to Compensation of Former DoD
Officials
SEP 2011
252.203-7002 Requirement to Inform Employees of Whistleblower Rights DEC 2022 252.203-7003 Agency Office of the Inspector General AUG 2019 252.203-7005 Representation Relating to Compensation of Former DoD
Officials
SEP 2022
252.204-7000 Disclosure Of Information OCT 2016 252.204-7003 Control Of Government Personnel Work Product APR 1992 252.204-7012 (Dev) Safeguarding Covered Defense Information and Cyber
Incident Reporting (DEVIATION 2024-O0013 REVISION 1)
MAY 2024
252.204-7015 Notice of Authorized Disclosure of Information for Litigation Support
JAN 2023
252.204-7016 Covered Defense Telecommunications Equipment or Services -- Representation
DEC 2019
252.204-7017 Prohibition on the Acquisition of Covered Defense Telecommunications Equipment or Services -- Representation
MAY 2021
252.204-7018 Prohibition on the Acquisition of Covered Defense Telecommunications Equipment or Services
JAN 2023
252.209-7004 Subcontracting With Firms That Are Owned or Controlled By The Government of a Country that is a State Sponsor of Terrorism
MAY 2019
252.211-7008 Use of Government-Assigned Serial Numbers SEP 2010 252.215-7007 Notice of Intent to Resolicit JUN 2012 252.215-7008 Only One Offer DEC 2022 252.223-7006 Prohibition On Storage, Treatment, and Disposal of Toxic or
Hazardous Materials
SEP 2014
252.223-7008 Prohibition of Hexavalent Chromium JAN 2023 252.225-7012 Preference For Certain Domestic Commodities APR 2022 252.225-7048 Export-Controlled Items JUN 2013 252.225-7052 Restriction on the Acquisition of Certain Magnets, Tantalum, and Tungsten.
MAY 2024
252.226-7001 Utilization of Indian Organizations, Indian-Owned Economic Enterprises, and Native Hawaiian Small Business Concerns
JAN 2023
252.227-7015 Technical Data--Commercial Products and Commercial Services
MAR 2023
252.227-7037 Validation of Restrictive Markings on Technical Data JAN 2023 252.232-7003 Electronic Submission of Payment Requests and Receiving
Reports
DEC 2018
252.232-7010 Levies on Contract Payments DEC 2006 252.243-7001 Pricing Of Contract Modifications DEC 1991 252.243-7002 Requests for Equitable Adjustment DEC 2022 252.244-7000 Subcontracts for Commercial Products or Commercial
Services
NOV 2023
252.247-7023 Transportation of Supplies by Sea OCT 2024
CLAUSES INCORPORATED BY FULL TEXT
52.204-5 WOMEN-OWNED BUSINESS (OTHER THAN SMALL BUSINESS) (OCT 2014)
(a) Definition. Women-owned business concern, as used in this provision, means a concern that is at least 51 percent owned by one or more women; or in the case of any publicly owned business, at least 51 percent of its stock is owned by one or more women; and whose management and daily business operations are controlled by one or more women.
(b) Representation. [Complete only if the offeror is a women-owned business concern and has not represented itself as a small business concern in paragraph (c)(1) of FAR 52.219-1, Small Business Program Representations, of this solicitation.] The offeror represents that it ( ___ ) is a women-owned business concern.
(End of provision)
52.204-17 OWNERSHIP OR CONTROL OF OFFEROR (AUG 2020)
(a) Definitions. As used in this provision--
Commercial and Government Entity (CAGE) code means—
(1) An identifier assigned to entities located in the United States or its outlying areas by the Defense Logistics Agency (DLA) Commercial and Government Entity (CAGE) Branch to identify a commercial or government entity by unique location; or
(2) An identifier assigned by a member of the North Atlantic Treaty Organization (NATO) or by the NATO Support and Procurement Agency (NSPA) to entities located outside the United States and its outlying areas that the DLA Commercial and Government Entity (CAGE) Branch records and maintains in the CAGE master file. This type of code is known as a NATO CAGE (NCAGE) code.
Highest-level owner means the entity that owns or controls an immediate owner of the offeror, or that owns or controls one or more entities that control an immediate owner of the offeror. No entity owns or exercises control of the highest level owner.
Immediate owner means an entity, other than the offeror, that has direct control of the offeror. Indicators of control include, but are not limited to, one or more of the following: Ownership or interlocking management, identity of interests among family members, shared facilities and equipment, and the common use of employees.
(b) The Offeror represents that it [ ___ ] has or [ ___ ] does not have an immediate owner. If the Offeror has more than one immediate owner (such as a joint venture), then the Offeror shall respond to paragraph (c) and if applicable, paragraph (d) of this provision for each participant in the joint venture.
(c) If the Offeror indicates ``has'' in paragraph (b) of this provision, enter the following information:
Immediate owner CAGE code:
Immediate owner legal name: ___
(Do not use a ``doing business as'' name)
Is the immediate owner owned or controlled by another entity?:
[ ___ ] Yes or [ ___ ] No.
(d) If the Offeror indicates ``yes'' in paragraph (c) of this provision, indicating that the immediate owner is owned or controlled by another entity, then enter the following information:
Highest-level owner CAGE code:
Highest-level owner legal name:
(Do not use a ``doing business as'' name)
(End of provision)
52.204-24 REPRESENTATION REGARDING CERTAIN TELECOMMUNICATIONS AND VIDEO
SURVEILLANCE SERVICES OR EQUIPMENT (NOV 2021)
The Offeror shall not complete the representation at paragraph (d)(1) of this provision if the Offeror has represented that it "does not provide covered telecommunications equipment or services as a part of its offered products or services to the Government in the performance of any contract, subcontract, or other contractual instrument" in paragraph (c)(1) in the provision at 52.204-26, Covered Telecommunications Equipment or Services--
Representation, or in paragraph (v)(2)(i) of the provision at 52.212-3, Offeror Representations and Certifications- Commercial Products and Commercial Services. The Offeror shall not complete the representation in paragraph (d)(2) of this provision if the Offeror has represented that it "does not use covered telecommunications equipment or services, or any equipment, system, or service that uses covered telecommunications equipment or services" in paragraph (c)(2) of the provision at 52.204-26, or in paragraph (v)(2)(ii) of the provision at 52.212-3.
(a) Definitions. As used in this provision-
Backhaul, covered telecommunications equipment or services, critical technology, interconnection arrangements, reasonable inquiry, roaming, and substantial or essential component have the meanings provided in the clause 52.204-25, Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment.
(b) Prohibition.
(1) Section 889(a)(1)(A) of the John S. McCain National Defense Authorization Act for Fiscal Year 2019 (Pub. L.
115-232) prohibits the head of an executive agency on or after August 13, 2019, from procuring or obtaining, or extending or renewing a contract to procure or obtain, any equipment, system, or service that uses covered telecommunications equipment or services as a substantial or essential component of any system, or as critical technology as part of any system. Nothing in the prohibition shall be construed to--
(i) Prohibit the head of an executive agency from procuring with an entity to provide a service that connects to the facilities of a third-party, such as backhaul, roaming, or interconnection arrangements; or
(ii) Cover telecommunications equipment that cannot route or redirect user data traffic or cannot permit visibility into any user data or packets that such equipment transmits or otherwise handles.
(2) Section 889(a)(1)(B) of the John S. McCain National Defense Authorization Act for Fiscal Year 2019 (Pub. L.
115-232) prohibits the head of an executive agency on or after August 13, 2020, from entering into a contract or extending or renewing a contract with an entity that uses any equipment, system, or service that uses covered telecommunications equipment or services as a substantial or essential component of any system, or as critical technology as part of any system. This prohibition applies to the use of covered telecommunications equipment or services, regardless of whether that use is in performance of work under a Federal contract. Nothing in the prohibition shall be construed to--
(i) Prohibit the head of an executive agency from procuring with an entity to provide a service that connects to the facilities of a third-party, such as backhaul, roaming, or interconnection arrangements; or
(ii) Cover telecommunications equipment that cannot route or redirect user data traffic or cannot permit visibility into any user data or packets that such equipment transmits or otherwise handles.
(c) Procedures. The Offeror shall review the list of excluded parties in the System for Award Management (SAM) (https://www.sam.gov) for entities excluded from receiving federal awards for "covered telecommunications equipment or services."
(d) Representations. The Offeror represents that--
(1) It [ ___ ] will, [ ___ ] will not provide covered telecommunications equipment or services to the Government in the performance of any contract, subcontract or other contractual instrument resulting from this solicitation. The Offeror shall provide the additional disclosure information required at paragraph (e)(1) of this section if the Offeror responds "will" in paragraph (d)(1) of this section; and
(2) After conducting a reasonable inquiry, for purposes of this representation, the Offeror represents that--
It [ ___ ] does, [ ___ ] does not use covered telecommunications equipment or services, or use any equipment, system, or service that uses covered telecommunications equipment or services. The Offeror shall provide the additional disclosure information required at paragraph (e)(2) of this section if the Offeror responds "does" in paragraph (d)(2) of this section.
(e) Disclosures.
(1) Disclosure for the representation in paragraph (d)(1) of this provision. If the Offeror has responded "will" in the representation in paragraph (d)(1) of this provision, the Offeror shall provide the following information as part of the offer:
(i) For covered equipment--
(A) The entity that produced the covered telecommunications equipment (include entity name, unique entity identifier, CAGE code, and whether the entity was the original equipment manufacturer (OEM) or a distributor, if known);
(B) A description of all covered telecommunications equipment offered (include brand; model number, such as OEM number, manufacturer part number, or wholesaler number; and item description, as applicable); and
(C) Explanation of the proposed use of covered telecommunications equipment and any factors relevant to determining if such use would be permissible under the prohibition in paragraph (b)(1) of this provision.
(ii) For covered services--
(A) If the service is related to item maintenance: A description of all covered telecommunications services offered (include on the item being maintained: Brand; model number, such as OEM number, manufacturer part number, or wholesaler number; and item description, as applicable); or
(B) If not associated with maintenance, the Product Service Code (PSC) of the service being provided; and explanation of the proposed use of covered telecommunications services and any factors relevant to determining if such use would be permissible under the prohibition in paragraph (b)(1) of this provision.
(2) Disclosure for the representation in paragraph (d)(2) of this provision. If the Offeror has responded "does" in the representation in paragraph (d)(2) of this provision, the Offeror shall provide the following information as part of the offer:
(i) For covered equipment--
(A) The entity that produced the covered telecommunications equipment (include entity name, unique entity identifier, CAGE code, and whether the entity was the OEM or a distributor, if known);
(B) A description of all covered telecommunications equipment offered (include brand; model number, such as OEM number, manufacturer part number, or wholesaler number; and item description, as applicable); and
(C) Explanation of the proposed use of covered telecommunications equipment and any factors relevant to determining if such use would be permissible under the prohibition in paragraph (b)(2) of this provision.
(ii) For covered services--
(A) If the service is related to item maintenance: A description of all covered telecommunications services offered (include on the item being maintained: Brand; model number, such as OEM number, manufacturer part number, or wholesaler number; and item description, as applicable); or
(B) If not associated with maintenance, the PSC of the service being provided; and explanation of the proposed use of covered telecommunications services and any factors relevant to determining if such use would be permissible under the prohibition in paragraph (b)(2) of this provision.
(End of provision)
52.204-26 COVERED TELECOMMUNICATIONS EQUIPMENT OR SERVICES--REPRESENTATION (OCT
2020)
(a) Definitions. As used in this provision, “covered telecommunications equipment or services” and "reasonable inquiry" have the meaning provided in the clause 52.204-25, Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment.
(b) Procedures. The Offeror shall review the list of excluded parties in the System for Award Management (SAM) (https://www.sam.gov) for entities excluded from receiving federal awards for “covered telecommunications equipment or services”.
(c) Representations.
(1) The Offeror represents that it [ ___ ] does, [ ___ ] does not provide covered telecommunications equipment or services as a part of its offered products or services to the Government in the performance of any contract, subcontract, or other contractual instrument.
(2) After conducting a reasonable inquiry for purposes of this representation, the offeror represents that it [ ___ ] does, [ ___ ] does not use covered telecommunications equipment or services, or any equipment, system, or service that uses covered telecommunications equipment or services.
(End of provision)
52.209-5 CERTIFICATION REGARDING RESPONSIBILITY MATTERS (AUG 2020)
(a)(1) The Offeror certifies, to the best of its knowledge and belief, that-
(i) The Offeror and/or any of its Principals-
(A) Are ( ) are not ( ) presently debarred, suspended, proposed for debarment, or declared ineligible for the award of contracts by any Federal agency;
(B) Have ( ) have not ( ), within a three-year period preceding this offer, been convicted of or had a civil judgment rendered against them for: commission of fraud or a criminal offense in connection with obtaining, attempting to obtain, or performing a public (Federal, State, or local) contract or subcontract; violation of Federal or State antitrust statutes relating to the submission of offers; or commission of embezzlement, theft, forgery, bribery, falsification or destruction of records, making false statements, tax evasion, violating Federal criminal tax laws, or receiving stolen property (if offeror checks “have”, the offeror shall also see 52.209-7, if included in this solicitation); and
(C) Are ( ) are not ( ) presently indicted for, or otherwise criminally or civilly charged by a governmental entity with, commission of any of the offenses enumerated in paragraph (a)(1)(i)(B) of this provision;
and
(D) Have , have not , within a three-year period preceding this offer, been notified of any delinquent Federal taxes in an amount that exceeds the threshold at 9.104-5(a)(2) for which the liability remains unsatisfied.
(1) Federal taxes are considered delinquent if both of the following criteria apply:
(i) The tax liability is finally determined. The liability is finally determined if it has been assessed. A liability is not finally determined if there is a pending administrative or judicial challenge. In the case of a judicial challenge to the liability, the liability is not finally determined until all judicial appeal rights have been exhausted.
(ii) The taxpayer is delinquent in making payment. A taxpayer is delinquent if the taxpayer has failed to pay the tax liability when full payment was due and required. A taxpayer is not delinquent in cases where enforced collection action is precluded.
(2) Examples. (i) The taxpayer has received a statutory notice of deficiency, under I.R.C. Sec. 6212, which entitles the taxpayer to seek Tax Court review of a proposed tax deficiency. This is not a delinquent tax because it is not a final tax liability. Should the taxpayer seek Tax Court review, this will not be a final tax liability until the taxpayer has exercised all judicial appeal rights.
(ii) The IRS has filed a notice of Federal tax lien with respect to an assessed tax liability, and the taxpayer has been issued a notice under I.R.C. Sec. 6320 entitling the taxpayer to request a hearing with the IRS Office of Appeals contesting the lien filing, and to further appeal to the Tax Court if the IRS determines to sustain the lien filing. In the course of the hearing, the taxpayer is entitled to contest the underlying tax liability because the taxpayer has had no prior opportunity to contest the liability. This is not a delinquent tax because it is not a final tax liability.