SECTION I: Requirement Information
1. Does this requirement contain performance-based components? If yes, please complete this form as a PWS and complete the Quality Assurance Surveillance Plan (QASP) in Section X.
[ ] Yes
[ x ] No
2. If there are no performance-based components, has a contract monitoring plan been attached to the SOW/PWS?
[ ] Yes
[ x ] No
SECTION II: Purpose
Product, Service or Outcome Needed:
The Transportation Security Administration (TSA) seeks to establish a Blanket Purchase Agreement (BPA) with a single contractor to procure explosives magazine for various approved locations following ATF guidelines.
Scope of the Product, Service, or Outcome:
The TSA seeks to establish a Blanket Purchas Agreement for five (5) years for the procurement of explosive magazines to be delivered throughout the CONUS and OCONUS. The contractor shall have the ability to provide a variety of magazines detailed in the Technical Requirements section below. The contractor will also provide a warranty to repair/repaint defective magazines.
SECTION III: Background
TSA utilizes this component in support of new and ongoing operations within the agency.
SECTION IV: Technical Requirements/Tasks/Outcomes
Technical Requirements 6ft L x 5 ft W x7 ft H Magazine
Contractor shall provide 6ft L x 5ft W x 7ft H magazines with the following specifications:
· Magazines must meet or exceed all U.S. Government (BATF) specifications found in Title 27, Code of Federal Regulations; Part 555; Subpart K; 555.208 (a-b)
· Magazines shall be a 6 feet L x 5 feet W x 7 feet H, Type 2 - outdoor, Class ABC, ATF spec (3 inch hardwood lined) magazine with (2) 6” “I” beam skids
· Magazines must have an entry door with two (2) high-security ATF approved hasps and hoods (must fit Medeco Lock 54-825K0 with 7/16” shackle)
· Magazines must have 110v NFPA approved explosion proof light (mounted as close to the inside wall as possible with externally mounted switch and disconnect)
· Magazines must have 20 inch wide reinforced non sparking plywood shelves. Three (3) rows of shelves on one side wall and the back wall forming an L Shape. Shelves to be spaced a minimum of 20” apart (horizontal separation) at 24inches, 44 inches, and 64 inches off the floor.
· Magazines must have 24 inch x 24 inch x 24 inch – Type 3, Class ABC, ATF spec (1/8 inch) aluminum, plywood lined day box with hinged lid bolted to floor of magazine
· Magazines must have NFPA ground kit with grounding rod, cable and brackets
· Magazines must have 30 inch x 30 inch x 30 inch, front opening, Type 2, Class ABC, ATF approved explosive storage magazine (attached to right exterior side of magazine) with 2 high security ATF approved hasps and hoods on door (must fit Medeco Lock 54-825K0 with 7/16” shackle).
· Magazines must be painted with rust and mold resistant gray paint 14ft Lx7 ft W x7 ft H Duplex Magazine Contractor shall provide 14ft L x 7t W x 7ft H duplex magazineswith the following specifications:
· Magazines must meet or exceed all U.S. Government (BATF) specifications found in Title 27, Code of Federal Regulations; Part 555; Subpart K; 555.208 (a-b)
· Magazines shall be a 14 feet L x 7 feet W x 7 feet H, Type 2 - outdoor, Class ABC, ATF spec (3 inch hardwood lined) magazine with (2) equal separated compartments of 7X7X7 (2) 6” “I” beam skids
· Magazines must have two entry doors with two (2) high-security ATF approved hasps and hoods each (must fit Medeco Lock 54-825K0 with 7/16” shackle)
· Magazines must have two 110v NFPA approved explosion proof lightis in each side of the magazine (mounted as close to the inside wall as possible with externally mounted switch and disconnect)
· Magazines must have 26 inch wide reinforced non sparking plywood shelves. Three (3) rows of shelves on one side wall and the back wall. Shelves to be spaced a minimum of 20” apart forming an L Shape (horizontal separation) at 24inches, 44 inches, and 64 inches off the floor.
· Magazines must have two (2) 30 inch x 24 inch x 24 inch – Type 3, Class ABC, ATF spec (1/8 inch) aluminum, plywood lined day box with hinged lid bolted to floor of magazine in each side of magazine.
· Magazines must have NFPA ground kit with grounding rod, cable and brackets
· Magazines must have two (2) 30 inch x 30 inch x 30 inch, front opening, Type 2, Class ABC, ATF approved explosive storage magazine (both attached to the right side of mag on top of each other separated by 10 inches) with 2 high security ATF approved hasps and hoods on each door must fit Medeco Lock 54-825K0 with 7/16” shackle.
· Magazines must be painted with rust and mold resistant gray paint 7ft L x 7ft W x7 ft H Magazine
Contractor shall provide 7ft L x 7ft W x 7ft H magazines with the following specifications:
· Magazines must meet or exceed all U.S. Government (BATF) specifications found in Title 27, Code of Federal Regulations; Part 555; Subpart K; 555.208 (a-b)
· Magazines shall be a 7 feet L x 7 feet W x 7 feet H, Type 2 - outdoor, Class ABC, ATF spec (3 inch hardwood lined) magazine with (2) 6” “I” beam skids
· Magazines must have an entry door with two (2) high-security ATF approved hasps and hoods (must fit Medeco Lock 54-825K0 with 7/16” shackle)
· Magazines must have 110v NFPA approved explosion proof light (mounted as close to the inside wall as possible with externally mounted switch and disconnect)
· Magazines must have 26 inch wide reinforced non sparking plywood shelves. Three (3) rows of shelves on one side wall and the back wall forming an L Shape. Shelves to be spaced a minimum of 20” apart (horizontal separation) at 24inches, 44 inches, and 64 inches off the floor.
· Magazines must have 30 inch x 24 inch x 24 inch – Type 3, Class ABC, ATF spec (1/8 inch) aluminum, plywood lined day box with hinged lid bolted to floor of magazine
· Magazines must have NFPA ground kit with grounding rod, cable and brackets
· Magazines must be painted with rust and mold resistant gray paint Special Delivery Instructions:
Contractor shall coordinate delivery with government POC which will be provided after contract award.
Contractor shall also coordinate delivery with site POCs provided at time of magazine order.
Performance/ Delivery Period:
The products due to, the the specified location, is no later than 60 days after contract award.
This BPA will be for five (5) years.
Place/ Location of Performance/ Delivery:
Delivery will be to various locations, both CONUS and OCONUS. TSA will provide the location and point of contact with each Delivery Order.
September 30, 2008 Version 2.0
HSTS02-13-R-NCP048