HSIP_11&12_Final_Plans_Rev.pdf
PDF 5 MB Posted
- Solicitation number
- IFB No. PW-0332
- Issued by
- Santa Cruz County, San Francisco City, California
About this file
HSIP 11 & 12: Unsignalized Crossing Improvement Project - Final Plans
This document consists of final construction plans for the Highway Safety Improvement Program (HSIP) 11 & 12 project in California, prepared for an unsignalized crossing improvement initiative. The project encompasses the installation of concrete curbs, gutters, sidewalks, curb ramps, roadway signs, pedestrian-activated beacons, and striping and pavement markings at designated locations. The scope of work requires contractors to furnish all necessary labor, materials, tools, equipment, and transportation to complete the project in accordance with the plans, City Standard Specifications, State Standard Specifications, and Special Provisions. The final plans document includes detailed technical drawings, specifications, and construction details necessary for bidders to accurately estimate project costs and execution requirements.
The plans serve as the contractual basis for competitive bidding and project execution. All work must be performed in strict compliance with the standards and specifications outlined in the documentation. Contractors are responsible for understanding the complete scope of work, including all items explicitly mentioned and any additional work required by the plans and applicable standards. The project focuses on pedestrian safety improvements at unsignalized crossings and represents a coordinated effort under California's Highway Safety Improvement Program to enhance traffic safety infrastructure.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HSIP_11&12_Final_Specifications_Rev.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REFERENCES
DRAWING #:
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
NOTES AND LEGENDS
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
2 14
PRECONSTRUCTION NOTES:
RAMP NOTES:
LEGEND:
PHONE NUMBERS:
(E) WATER LINE
SD SD (E) STORM DRAIN LINE
SS SS (E) SANITARY SEWER LINE
E E (E) ELECTRICAL LINE
x x x x x (E) FENCE LINE
(E) PARCEL LINE
(E) TRAFFIC PULL BOX
(E) WATER VALVE
(E) UTILITY POLE
(E) SIGN AND POLE
(E) CATCH BASIN
W
T
SD
SS
W
(E) TREE
(E) WATER MANHOLE
(E) SEWER MANHOLE
(E) STORM DRAIN MANHOLE
(E) 20-40 FT PALM
(E) FIRE HYDRANT
FLOW (E) STORM WATER SURFACE FLOW
(E) CABINET: ELECTRICAL, FIBER, ETC.
*AREA CODE IS 831 UNLESS OTHERWISE NOTED
POLICE DEPARTMENT...................... 420-5800 (ADMINISTRATION)
471-1130 (DISPATCH)
911 (EMERGENCY)
FIRE DEPARTMENT........................... 420-5280 (ADMINISTRATION)
471-1170 (ADMINISTRATION)
911 (EMERGENCY)
PUBLIC WORKS DEPARTMENT........ 420-5160
WATER DEPARTMENT...................... 420-5210
1. THE CONTRACTOR IS RESPONSIBLE FOR THE INTENT OF THESE PLANS AND S/HE SHALL REPORT ANY DISCREPANCIES FOUND IN THEM TO THE
ENGINEER PRIOR TO CONSTRUCTION.
2. UNDERGROUND UTILITY LOCATIONS AND DEPTHS, WHERE SHOWN ON THE PLANS, ARE BASED ON UTILITY COMPANY RECORDS AND ARE FOR GENERAL INFORMATION ONLY. THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF LOCATIONS AND DEPTHS FOR ALL EXISTING UTILITIES
IN THE FIELD.
3. THE CONTRACTOR SHALL POSSESS A CLASS A LICENSE AT THE TIME THIS CONTRACT IS AWARDED. THE CONTRACTOR SHALL HAVE A CITY
BUSINESS LICENSE PRIOR TO COMMENCING THE WORK.
4. CITY INSPECTOR SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ANY CONSTRUCTION.
5. THE CONTRACTOR SHALL CONTACT THE ENGINEER IF PRIVATE IMPROVEMENTS CONTINUE TO BE IN THE CITY RIGHT-OF-WAY PRIOR TO ANY DEMOLITION, CLEARING, AND GRUBBING. UPON DIRECTION OF THE ENGINEER, THE CONTRACTOR SHALL CAREFULLY REMOVE PRIVATE IMPROVEMENTS IN THE CONSTRUCTION AREA AND CAP ANY EXISTING IRRIGATION, ELECTRICAL, AND/OR DRAINAGE AT THE BACK OF NEW WALK.
1. PRESERVE AND PROTECT EXISTING UTILITIES (I.E. - MANHOLES, METERS, FIRE HYDRANTS, ETC.)
2. ALL CONCRETE SHALL BE SIX SACK, CLASS "A" CONCRETE.
3. CURB, GUTTER, SIDEWALK AND SPANDREL/VALLEY GUTTER SHALL BE A MONOLITHIC POUR WHEREVER POSSIBLE.
4. THE RAMP SHALL HAVE A ROUGH TRANSVERSE BROOMED TEXTURE.
5. NATIVE SUBBASE SHALL BE COMPACTED TO 95%. IF MATERIAL IS SILT OR CLAY IT SHALL BE "FIRM" ACCORDING TO ASTM D1556. OTHERWISE EXCAVATE TO 12" BELOW FINISH GRADE AND REPLACE WITH CLASS II AGGREGATE BASE AND COMPACT.
6. THE CURB AND GUTTER ADJACENT TO THE RAMP LANDING SHALL BE MODIFIED SO THAT THE CROSS SLOPE OF THE GUTTER DOES NOT EXCEED 5%.
7. ANY NEW PCC CURB, GUTTER, AND SIDEWALK NEXT TO THE EXISTING PCC, SHALL BE DOWELED INTO EXISTING PCC EVERY 24" ON CENTER.
USE 18" LONG #4 DOWELS.
8. SEE "STANDARD CURB, GUTTER & SIDEWALK" ON DETAILS SHEET FOR TYPICAL SECTION VIEW AND FURTHER REQUIREMENTS.
9. SPANDRELS SHALL BE REINFORCED WITH #4 BARS AT 18" O.C. BOTH WAYS OR WELDED WIRE MESH 4"X4" W4XW4, AND SHALL HAVE A MINIMUM
OF 2" OF COVER. SEE SPANDREL/VALLEY GUTTER DETAIL FOR FURTHER REQUIREMENTS.
10. ALL NEW AC SHALL BE INSTALLED PER AC CONFORM ON CURB, GUTTER, AND SIDEWALK DETAILS.
W M
(E) WATER METER
G (E) GAS
(E) STREETLIGHT
PARK & REC. DEPARTMENT............ 420-5270
PG&E................................................... 476-9393
PACIFIC BELL..................................... 611-CITY
U.S.A................................................... (800) 227-2600
CABLE T.V.......................................... 425-1739.
W W sco (E) SEWER CLEANOUT
(E) FLASHING BEACON
(N) SIGN AND POLE
(E) ELECTRICAL PULL BOXE
(N) TRAFFIC PULL BOX
(N) ELECTRICAL PULL BOX
(N) STORM WATER SURFACE FLOW
(N) CONCRETE
(N) RED CURB
(N) DETECTABLE WARNING SURFACE
(N) A.C. CONFORM AREA
(N) RETAINING CURB
T E
FLOW
(E) WATER BACKFLOW DEVICE (E) INTERCONNECTSIC SIC
SC SC
(E) TRAFFIC SIGNAL
CONDUIT
E E (N) ELECTRICAL LINE
(E) INTERCONNECT PULL BOXIC
(N) RRFB ASSEMBLY COMBINED PUSH
BUTTON POST (2.5 In. NPS)
DEMO AREA
(N) RRFB ASSEMBLY (BI-DIRECTIONAL)
WITH TYPE 1B POST (4 In. NPS)
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
LAUREL ST
BLAC
KBU
R N
ST
M
YR
TLE ST
FE
LIX
S T
BLAC
KBU
R N
ST
LAUREL ST
REFERENCES
DRAWING #:
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
LAUREL STREET & BLACKBURN STREET
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
3 14
(E) S1-1 AND S4-3P SIGNS
(E) R1-5L SIGN TO REMAIN
(E) R1-5L SIGN TO REMAIN
LEGENDS: (THIS SHEET ONLY)
ACC: (N) AC CONFORM
CON: INSTALL (N) 2" SCHEDULE 40 CONDUIT AND CONDUCTORS WITH 5'
SLACK IN THE PULL BOX. COMPLETE CONNECTIONS FOR FULL
TRAFFIC SIGNAL OPERATION
DEMO: REMOVE (E) AC, SIDEWALK, RAMP, CURB AND GUTTER
DWSC: INSTALL DETECTABLE WARNING SURFACE (CAST IN PLACE)
PB: INSTALL CALTRANS #3-1/2 PULL BOX
PBAP: INSTALL PUSH BUTTON ASSEMBLY POST
RMP-C: CONSTRUCT (N) CALTRANS CASE 'C' PEDESTRIAN RAMP WITH
RETAINING CURB
RRFB: INSTALL (N) RECTANGULAR RAPID FLASHING BEACON ASSEMBLY.
RSP: REMOVE (E) SIGN POST
RLS2: RELOCATE (E) SIGNS (S1-1 AND W16-7P) TO (N) RRFB POST
RLS5: RELOCATE (E) SIGNS (S1-1(2 EA), W16-7P( L/R)(2 EA) AND R1-6) TO
(N) RRFB POST
SWK: (N) SIDEWALK
SCALE: 1" = 40' SEE DETAIL A
DETAIL A
SCALE: 1" = 20'
(E) R1-6 SIGN TO REMAIN
CONSTRUCTION NOTES: (THIS SHEET ONLY)
1. CONTRACTORS SHALL LOCATE EXISTING UNDERGROUND
UTILITIES PRIOR TO CONSTRUCTION.
RSP RLS2 1 EAPB 1 EA CON 20 LF
PBAP 1 EA
(E) R1-5
(E) R1-5
DEMO SWK 15 SF
(E) R1-6
RRFB 1 EA
RSP RLS5 1 EA
RRFB 1 EA
RSP RLS2 1 EA
RRFB 1 EA
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
DEMO 317 SF
ACC 60 SF
RMP-C 257 SF
DWSC 15 SF
BROADWAY
PEN
N
SYLVAN
IA
BROADWAY
P E
N N
S Y
LV
A
N
IA
A V
E
REFERENCES
DRAWING #:
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
BROADWAY & PENNSYLVANIA AVENUE
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
4 14
SCALE: 1" = 20'
CONSTRUCTION NOTES: (THIS SHEET ONLY)
1. CONTRACTORS SHALL VERIFY THE LOCATION OF EXISTING
UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION.
LEGENDS: (THIS SHEET ONLY)
39Z: DETAIL 39Z (PER CITY STD DETAIL T-10)
CON: INSTALL (N) 2" SCHEDULE 40 CONDUIT AND CONDUCTORS WITH 5' SLACK IN THE PULL BOX.
COMPLETE CONNECTIONS FOR FULL TRAFFIC SIGNAL OPERATION
CRBR: PAINT CURB RED
PB: INSTALL CALTRANS #3-1/2 PULL BOX
PBAP: INSTALL PUSH BUTTON ASSEMBLY POLE
PST: INSTALL (N) STANDARD SIGN POST
R1-5: (N) R1-5(L/R) SIGN (YIELD HERE) (24" x 24")
RLS4: RELOCATE (E) SIGNS (W11-2 (2 EA) AND W16-7P (2 EA)) TO (N) RRFB POST
RRFB: INSTALL (N) RECTANGULAR RAPID FLASHING BEACON ASSEMBLY.
RSP: REMOVE (E) SIGN POST
RSTR: REMOVE (E) STRIPES
YL: YIELD LINE (PER CITY STD DETAIL T-9)
SCALE: 1" = 40'
SEE DETAIL
THIS SHEET SEE DETAIL 1
ON SHEET 8
SEE DETAIL 2
ON SHEET 8
RSP RLS4 1 EA
PB 1 EA
CON 12 LF
PBAP 1 EA
RSP RLS4 1 EA
PB 1 EA
PBAP 6 LF
CON 12 LF
RSTR 100 LF
CWW 70 LF
RSTR 60 LF
CWW 70 LF
RSTR 80 LF
CWW 70 LF
PST RI-5L 1 EA
YL 14 LF
PST RI-5L 1 EA
YL 14 LF
CRBR 20 LF
CRBR 20 LF
39Z 45 LF
39Z 45 LF
RRFB 1 EA
RRFB 1 EA
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
R = 7.5 L
.6
R = 10 L = 6.2 R = 10 L = 4.2
L = 6.0 R = 8 L = 12.6
L = 10.0
R = 10.5 L = 8
R = 14.5 L = 11 L = 5.7 R = 8 L = 12.6 L = 6.9
R = 12 L = 8.1
R = 10.5 L = 7.2
REFERENCES
DRAWING #:
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
DETAIL - BROADWAY & PENNSYLVANIA AVENUE
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
5 14
CONSTRUCTION NOTES: (THIS SHEET ONLY)
1. CONTRACTORS SHALL VERIFY THE LOCATION OF EXISTING
UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION.
DETAIL 2
NO SCALE
LEGENDS: (THIS SHEET ONLY)
ACC: (N) AC CONFORM
AG: INSTALL ADA FRAME AND GRATE. FRAME SHALL BE IRONSMITH 9000F-X (OR
APPROVED EQUAL). GRATE SHALL BE IRONSMITH 9032-18 (OR APPROVED
EQUAL)
C&G: INSTALL (N) CURB AND GUTTER
DEMO: REMOVE (E) AC, SIDEWALK, RAMP, CURB AND GUTTER
DWS: INSTALL DETECTABLE WARNING SURFACE (CAST IN PLACE)
RMP-G: CONSTRUCT (N) CALTRANS CASE 'G' PEDESTRIAN RAMP
RRCK: 4" TO 6" DIA. GREY RIVER ROCK EMBEDDED 2" - 3" INTO WET CONCRETE.
ONE LAYER OF ROCKS WITH ROUNDED SIZE EXPOSED.
SWK: CONSTRUCT (N) SIDEWALK
DETAIL 1
NO SCALE
(E) A.C.
SECTION A-A
NTS
(N) A.C.
CONFORM
GUTTER
1.5% MAX
7.5% MAX
RAMP
5% MAX
8.33% MAX
6"
6"
MATCH (E)
FLOWLINE
6"
1'-6"
(N) COMPACTED
CLASS II A.B.
DEMO 780 SF
ACC 233 SF
RMP-G 83 SF
C&G 60 LF
DWS 15 SF
SWK 308 SF
DWS 15 SF
DEMO 612 SF
ACC 162 SF
RMP-G 55 SF
C&G 52 LF
SWK 237 SF
DWS 15 SF
DWS 15 SF
AG 1 EA
ADJUST (E) PULLBOX TO
FINISHED GRADE
PROTECT (E) STREET
LIGHT IN PLACE
PROTECT (E) FIRE
HYDRANT IN PLACE
ADJUST (E) WATER VALVE
TO FINISHED GRADE
SIDEWALK
(N) ADA GRATE
AND FRAME
FLOWFLOW
7'
FLOW
FL
O
W
FL
O
W
RRCK 14 SF
RRCK 21 LF
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
FLOW
7'
5' 21.5'
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text A
A
R = 2'
R = 6'
R = 1 0'
R = 6
L = 4'-5"
L
2'
R
SEABRIGHT AVE
LO
G
A N
S T
R = 2'
R = 6'
R = 1 0'
R = 6
L = 4'-5"
L
2'
R
LO
G
A N
S T
SEABRIGHT AVE
11' 17'
REFERENCES
DRAWING #:
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
SEABRIGHT AVENUE & LOGAN STREET
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
6 14
SCALE: 1" = 40'
SEE DETAIL
THIS SHEET
LEGENDS: (THIS SHEET ONLY)
ACC: (N) AC CONFORM
C&G: INSTALL (N) CURB AND GUTTER
CRBR: PAINT CURB RED
CWW CONTINENTAL CROSSWALK WHITE
(PER CITY STD DETAIL T-9)
D22: DETAIL 22 STRIPE
D39Z: DETAIL 39Z (PER CITY STD DETAIL T-10)
DEMO: REMOVE (E) AC, SIDEWALK, RAMP,
CURB AND GUTTER
DWSC: INSTALL DETECTABLE WARNING
SURFACE (CAST IN PLACE)
LL: LIMIT LINE (12" WHITE LINE)
PST: INSTALL (N) STANDARD SIGN POST
SWK: CONSTRUCK (N) SIDEWALK
R1-5L: (N) R1-5(L) SIGN (YIELD HERE) (24" x 24")
RMP-G CONSTRUCT (N) CALTRANS CASE 'G'
PEDESTRIAN RAMP
RRCK: 4" TO 6" DIA. GREY RIVER ROCK
EMBEDDED 2" - 3" INTO WET
CONCRETE. ONE LAYER OF ROCKS
WITH ROUNDED SIZE EXPOSED.
RRFB: INSTALL (N) RECTANGULAR RAPID
FLASHING BEACON ASSEMBLY.
RSP: REMOVE (E) SIGN POST
RLS2: RELOCATE (E) SIGNS (W11-2 AND
W16-7P) TO (N) RRFB POST
RMRK: REMOVE (E) MARKING
RSTR: REMOVE (E) STRIPES
STP: "STOP MARKING"
W11-2: (N) W11-2 SIGN (PEDESTRIAN
CROSSING) (30" x 30")
W16-7P: (N) W16-7P(R) SIGN (DIRECTIONAL
ARROW) (30" X 18")
YL: (N) YIELD LINE
RSP RLS2 1 EA
RSTR D22 30 LF
YL 14 LF
PST R1-5L 1 EA
YL 11 LF
(E) W11-2 SIGN
RSTR 72 LF
DEMO 680 SF
W11-2 W16-7P 1 EA
W11-2 W16-7P 1 EA
CONSTRUCTION NOTES: (THIS SHEET ONLY)
1. CONTRACTORS SHALL LOCATE EXISTING UNDERGROUND
UTILITIES PRIOR TO CONSTRUCTION.
CURB EXTENSION DETAIL
SCALE: 1" = 6'
ACC 255 SF
RMP-G 50 SF
DWSC 15 SF
SW 168 SF
PROTECT (E)
R1-1 SIGN AND
POST IN PLACE
RMP-G 40 SF
DWSC 15 SF
(E) GUTTER LIP
6'
6'
D22 25 LF
SCALE: 1" = 20'
SEE CURB EXTENSION
DETAIL THIS SHEET
C&G 48 LF
(E) 1B POLE TO REMAIN
CRBR 30 LF
RLS2 1 EA
D39Z 50 LF
RRFB 1 EA
RRFB 1 EA
RRCK 25 SF
LL 12 LF
PST R1-5L 1 EA
CWW 50 LF
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
RMRK STP 22 SF
HIGH ST
C A
R D
IFF P
L
WESTMOOR DR
REFERENCES
DRAWING #:
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
HIGH STREET & CARDIFF PLACE
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
7 14
LEGENDS: (THIS SHEET ONLY)
A4: CALTRANS ARROW TYPE 4(L/R)
BTAG: BIKE AND THROUGH ARROW WITH GREEN VIZIGRIP
CWY CONTINENTAL CROSSWALK YELLOW (PER CITY STD
DETAIL T-9)
D22: DETAIL 22 STRIPE
D27B: DETAIL 27B STRIPE
D29: DETAIL 29 STRIPE
D39A: DETAIL 39A STRIPE
D39: DETAIL 39 STRIPE
D39Z: DETAIL 39Z (MODIFIED BIKE LANE LINE PER CITY
STD DETAIL T-10)
DYLT: DAYLIGHTING STRIPE (PER CITY STD DETAIL T-12)
LL: LIMIT LINE (PER CITY STD DETAIL T-9)
N-5: TYPE N-5 (CA) OBJECT MARKER
PST: INSTALL (N) STANDARD SIGN POST
R1-5: R1-5 SIGN (24" x 24")
RMRK: REMOVE (E) MARKING
RS1: REMOVE (E) S1-1 SIGN
RSP: REMOVE (E) SIGN POST
RSTR: REMOVE (E) STRIPES
SHRG: SHARROW MARKING WITH GREEN VIZIGIP
STP: STOP LEGEND (PER CITY STD DETAIL T-9)
W11-15 (N) W11-15 SIGN (30" x 30") W16-9p: (N) W16-9P SIGN (30" x 18")
YL: YIELD LINE (PER CITY STD DETAIL T-9)
SEE DETAIL
ON SHEET 11
(E) MAILBOX
RSTR 120 LF
RSP RS1 1 EA
PST W11-15W16-9P 1 EA
RSP RS1 1 EA
PST W11-15W16-9P 1 EA
LL 16 LF
BTAG 1 EA
DYLT 30 LF
RMRK 74 SF
SHRG 1 EA
D22 50 LF
CWY 100 LF
D39Z 72 LF
YL 14 LF
YL 20 LF
PST R1-5 1 EA
STP 1 EA
A4 30 SF
BTAG 1 EA
D39 36 LF
RSTR 110 LF
D39 184 LF
D27B 238 LF
39A 50 LF
(E)
PATHWAY
PST N-5 1 EA
RSTR 50 LF
D29 82 LF
CWY 80 LF
PST R1-5 1 EA
13'
SCALE: 1" = 40'
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
MH
C A
R D
IFF P
L
HIGH ST
CONSTRUCTION NOTES: (THIS SHEET ONLY)
1. CONTRACTORS SHALL LOCATE EXISTING
UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION.
LEGENDS: (THIS SHEET ONLY)
ACC: (N) AC CONFORM
C&G: CONSTRUCT (N) CURB AND GUTTER
DEMO: REMOVE (E) AC, SIDEWALK, RAMP, CURB AND GUTTE
DWSC: INSTALL DETECTABLE WARNING SURFACE (CAST IN PLACE)
PST: INSTALL (N) STANDARD SIGN POST
RLS2: RELOCATE (E) SIGNS (R2-1(25) AND R26) TO (N) POST
RLS1-1: RELOCATE (E) SIGN (W16-7P) TO (N) RRFB POST
RLS1-2: RELOCATE (E) SIGN (R1-1) TO (N) RRFB POST
RS1: REMOVE (E) SIGN (S1-1)
RSP: REMOVE (E) SIGN POST
RRCK: 4" TO 6" DIA. GREY RIVER ROCK EMBEDDED 2" - 3" INTO WET
CONCRETE. ONE LAYER OF ROCKS WITH ROUNDED SIZE EXPOSED.
RMP-C: CONSTRUCT (N) CALTRANS CASE 'C' PEDESTRIAN RAMP WITH
RETAINING CURB
RRFB: INSTALL (N) RECTANGULAR RAPID FLASHING BEACON ASSEMBLY.
SWK: CONSTRUCT (N) SIDEWALK
TB3: (N) CALTRANS TYPE B3 CURB
W11-15: (N) W11-15 SIGN (30" x 30")
W16-7P: (N) MODIFIED W16-7P(L/R) SIGN (DIRECTIONAL ARROW) (30" X 18") (SEE
DETAIL THIS SHEET)
REFERENCES
DRAWING #:
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
DETAIL - HIGH STREET & CARDIFF PLACE
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
8 14
DEMO 217 SF
(E)
PATHWAY
ACC 48 SF
RMP-C 154 SF
DWSC 15 SF
DEMO 235 SF
SWK 136 SF
C&G 20 LF
ACC 42 SF
DEMO 225 SF
ACC 50 SF
RMP-C 160 SF
DWSC 15 SF
TYPE A PASSAGEWAY DETAIL
NOT TO SCALE
TYPE A PASSAGEWAY (SEE
DETAIL THIS SHEET AND CITY
STD DETAIL T-16)
9' 6' 9'
7'
R = 3.5' (TYP)
R = 1.5' (TYP)
TB3 28 LF
ACC 12 SF
TB3 28 LF
DEMO 66 SF
RRCK 44 SF
ACC 12 SF
TB3 28 LF
RRCK 44 SF
SWK 42 SF
DWSC 36 SF
RSP RLS2 PST 1 EA FROMTO
RSP RS1 RLS1-1 1 EA
RRFB RLS1-1W11-15 1 EA
DEMO 129 SF
ACC 29 SF
SWK 57 SF
C&G 14 LF
RSP RS1 RLS1-1 1 EA
RSP RRFB RLS1-2 1 EA
RRFB 1 EA
30"
18"
MODIFIED W16-7P(L/R)
NOT TO SCALE
W16-7PW11-15 2 EA
RRFB 1 EA
RRFB W11-15 1 EA
CORNER ISLAND DETAIL
NOT TO SCALE
9'-8"
R = 10'
R = 28' 3'
8'-8"R = 2'
TB3 56 LF
RRCK 145 SF
CORNER ISLAND
(SEE DETAIL THIS SHEET
AND CITY STD DETAIL T-16)
SCALE: 1" = 40'
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
MH
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
SOQUEL AVENUE & POPLAR STREET
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
09 14
SCALE: 1" = 30'
CONSTRUCTION NOTES:
1. CONTRACTORS SHALL LOCATE EXISTING UNDERGROUND UTILITIES PRIOR
TO CONSTRUCTION.
LEGENDS: (THIS SHEET ONLY)
12" Y: 12 INCH YELLOW THERMOPLASTIC STRIPE
CWW: CONTINENTAL CROSSWALK WHITE (PER CITY STD DETAIL T-9)
D21: DETAIL 21 STRIPE
RSTR: REMOVE (E) STRIPING LINE
YL: (N) YIELD LINE
SEE DETAIL ON
SHEET 13
(E) R1-5L SIGN TO
REMAIN
(E) W11-2 AND R81 SIGNS TO REMAIN
RSTR 70 LF
RSTR 50 LF
RSTR 80 LF
PROTECT (E) STREET
LIGHT IN PLACE CWW 60 LF
CWW 60 LF
CWW 50 LF
REMOVE (E) POST
RELOCATE (E) R1-5 SIGN
WITH (N) POST
FROM
TO
YL 23 LF
YL 17 LF
YL 20 LF
REMOVE (E) STREET
NAME SIGN AND POST
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
D21 15 LF
12" Y 20 LF
SD
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
DETAIL - SOQUEL AVENUE & POPLAR STREET
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 AS SHOWN
10 14
SCALE: 1" = 40'
CONSTRUCTION NOTES:
1. CONTRACTORS SHALL LOCATE EXISTING UNDERGROUND UTILITIES PRIOR TO
CONSTRUCTION.
LEGENDS: (THIS SHEET ONLY)
4" W: 4 INCH WHITE THERMOPLASTIC STRIPE
ACC: (N) AC CONFORM
CON: INSTALL (N) 2" SCHEDULE 40 CONDUIT AND CONDUCTORS WITH 5' SLACK IN
THE PULL BOX. COMPLETE CONNECTIONS FOR FULL TRAFFIC SIGNAL
OPERATION
DEMO: REMOVE (E) AC, SIDEWALK, RAMP, CURB AND GUTTER
DWSC: INSTALL DETECTABLE WARNING SURFACE (CAST IN PLACE)
PB: INSTALL CALTRANS #3-1/2 PULL BOX
PBAP: INSTALL PUSH BUTTON ASSEMBLY POST
PST: INSTALL (N) STANDARD SIGN POST
R1-5: (N) R1-5(L/R) SIGN (YIELD HERE) (24" x 24")
RMP-C CONSTRUCT (N) CALTRANS CASE 'C' PEDESTRIAN RAMP
RRFB: INSTALL (N) RECTANGULAR RAPID FLASHING BEACON ASSEMBLY.
RSP: REMOVE (E) SIGN POST
RLS2: RELOCATE (E) SIGNS (W11-2 AND W16-7P) TO (N) RRFB POST
RLS1: RELOCATE (E) SIGN (W11-2) TO (N) RRFB POST
RS1: REMOVE (E) SIGN (W16-7P)
SWK: CONSTRUCT (N) SIDEWALK
TB3: (N) CALTRANS TYPE B3 CURB
W16-7P: (N) MODIFIED W16-7P(L/R) SIGN (DIRECTIONAL ARROW) (30" X 18") (SEE DETAIL
THIS SHEET)
PST RI-5 1 EA
RSP RLS2 1 EA
RSP RS1 1 EA
RSP RLS2 1 EA
RRFB RLS2 1 EA
DEMO SWK 14 SF
DWS 15 SF
RMP-C 104 SFDEMO 1400 SF
SWK 302 SF
DWSC 81 SF
TRIM (E) ISLAND (SEE
DETAIL 1 THIS SHEET)
TB3 33 LF
TB3 31 LF
25'
25'
R = 37'
R = 37'
DETAIL 1
NOT TO SCALE
(E) POST AND R32 SIGN
TO REMAIN
TB3 22 LF
10'
10'
10'
4" W 26 LF
4" W 31 LFRRFB RLS2 1 EA
RRFB 1 EA
RRFB 1 EA
ACC 32 SF
ACC 25 SF
ACC 913 SF
RRFB RLS1 W16-7P 1 EA
30"
18"
MODIFIED W16-7P(L/R)
NOT TO SCALE
4" W 26 LF
CON 30 LF
PB 2 EA
PBAP 2 EA
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
AutoCAD SHX Text
SD
SD
7'
0" M
IN
W11-2 SIGN
RECTANGULAR RAPID
FLASHING BEACON (RRFB)
W16-7P SIGN
CONTROL CABINET
ENCLOSURE. MOUNT
CENTERED BEHIND SIGN
(IF BI-DIRECTIONAL SIGN,
MOUNT ABOVE SIGNS)
MOUNTING BRACKET
AND STEEL STRAP
SIDE ELEVATION
3'
6"
ACTIVATION PUSH BUTTON
AND R10-25 SIGN (NOTE 9)
(IF PUSH BUTTON IS REQUIRED ON
SEPARATE POLE, SEE DETAIL E)
4 NPS STANDARD PIPE
(THREAD BOTH END 5/8")
18" MIN.
(NOTE 8)
OR
S1-1 SIGN IN SCHOOL ZONE
(TABLE, NOTE 4)
SOLAR PANEL ASSEMBLY
WITH ROUND POST MOUNT
NOTE 5
FACE OF CURB
RRFB ELEVATION
2'-6"Ø
6'
/4
M
IN
T
O
M
A X
30" X 3/4"Ø
ANCHOR
BOLTS
(4 TOTAL)
DRAIN
HOLE
ANCHOR BOLT
THREAD TOP 8",
GALVANIZE 1'-0"
TOP OF
GRADE
MORTAR
(NOTE 2)
ANCHOR
PLATE
REBAR
(DETAIL C)
DETAIL A - FOUNDATION
AND ANCHORAGE
DETAIL B - POLE
BASE PLAN DETAIL C - FOUNDATION PLAN
3"
CLEARANCE
FROM
OUTER
EDGES AND
BOTTOM,
TYP.
#4 SPIRAL
REBAR AT 6"
#6 VERTICAL
REBAR
(10 TOTAL)
CONCRETE
PAD (NOTE 7)
4"x10" CLASS 250
GALV. CAST IRON
PIPE FLANGE
TOTAL
NUMBER
OF HOLES
MAY VARY
77/8" BOLT
CIRCLE
FOUNDATION
(DETAIL A)
TO PUSH
BUTTON POLE,
IF APPLICABLE
POLE BASE
(DETAIL B)
NOTES:
1. ALL EQUIPMENT AND APPURTENANCES TO BE INSTALLED PER MANUFACTURER SPECIFICATION AND LATEST CALTRANS
STANDARD PLANS.
2. GROUT FLUSH WITH BASE PLATE.
3. 4' MINIMUM (5' RECOMMENDED) CLEARANCE BETWEEN EDGE OF POLE AND BACK OF WALK.
4. EDGE OF SIGN SHALL BE SET BACK 6" MIN. FROM FACE OF CURB. SIGN MAY BE MOUNTED OFF CENTER FROM POST TO
ACCOMMODATE THE 6" SETBACK.
5. SIGN SHALL HAVE A FLUORESCENT YELLOW-GREEN BACKGROUND WITH BLACK LEGEND AND BORDER.
6. CONCRETE FOUNDATION SHALL BE CLASS "A" CONCRETE FIELD CAST, 4,500 PSI MIN.
7. CONCRETE PAD SHALL BE CLASS "A" CONCRETE FIELD CAST, 36" x 36" x 4", 4,000 PSI. CONCRETE PAD SHALL BE POURED
SEPARATELY FROM FOUNDATION AND INSTALLED AFTER LEVELING POLE.
8. LOCATION OF POLES AND PEDESTRIAN PUSH BUTTON SHALL BE APPROVED BY THE CITY ENGINEER BEFORE
INSTALLATION.
9. PEDESTRIAN PUSH BUTTON SHALL BE EQUIPPED WITH AUDIBLE INFORMATION AND BE COMPLIANT WITH THE LATEST
MUTCD AND ADA GUIDELINES.
SIGN DIMENSIONS
SIGN
W11-2 S1-1
W16-7P
DIMENSION (INCHES)
MINIMUM
£ 25 mph
CONVENTIONAL* OVERSIZED
*CONVENTIONAL DIMENSION SHALL BE USED
UNLESS SPECIFIED OTHERWISE
30X30 36X36 48X48 30X30 36X36 48X48 24X12 24X12 30X18
NOTE 2
ACTIVATION PUSH BUTTON
AND R10-25 SIGN (NOTE 9)
5/8" Ø x 1'
ANCHOR BOLTS
18" MIN.
(NOTE 8)
DETAIL E - PUSH BUTTON ASSEMBLY POLE
REMOVABLE RAIN
TIGHT CAP
4 NPS STANDARD PIPE
18" Ø
2'
3'
6"
CONCRETE
PAD (NOTE 7)
TABLE 1 - SIGN DIMENSIONS
TO RRFB POLE
CALTRANS 3-1/2
PULLBOX
4"
6" CL. 2 AB
14"
1" DIA. CONDUIT
SCH. 40 PVC
POLE BASE
(DETAIL F)
DETAIL F - POLE
BASE PLAN
7" BOLT CIRCLE
CUT HOLE TO
FIT PIPE
3/4" Ø HOLE
7"
7"
45° 45°
90° (TYP.)
REFERENCES
DRAWING #:
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
DETAIL SHEET
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 NO SCALE
11 14
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
DETAIL SHEET
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 NO SCALE
12 14
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
AutoCAD SHX Text
RAISED TRUNCATED DOME
AutoCAD SHX Text
RAISED TRUNCATED DOME PATTERN (IN-LINE)
AutoCAD SHX Text
DETECTABLE WARNING SURFACE
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text
RETAINING CURB IF NECESSARY AT EDGE OF SIDEWALK
AutoCAD SHX Text
CASE B
AutoCAD SHX Text
FRONT EDGE OF SIDEWALK
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
CROSSWALK IF PROVIDED
AutoCAD SHX Text
CROSSWALK IF PROVIDED
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text Max
AutoCAD SHX Text 1:1 Typ
AutoCAD SHX Text 1:1 Typ
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text
CASE D
AutoCAD SHX Text
FRONT EDGE OF SIDEWALK
AutoCAD SHX Text
PLANTING AREA
AutoCAD SHX Text
FRONT EDGE OF SIDEWALK
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text
CASE E
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text 6" Typ
AutoCAD SHX Text A
AutoCAD SHX Text Max
AutoCAD SHX Text
CASE A
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text 6" Typ
AutoCAD SHX Text 5'-0" Min
AutoCAD SHX Text A
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
LANDING
AutoCAD SHX Text
LANDING
AutoCAD SHX Text
FLARE
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
FLARE
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
DETAIL A
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 7.5%
AutoCAD SHX Text 7.5% Max
AutoCAD SHX Text 7.5% Max
AutoCAD SHX Text 7.5% Max
AutoCAD SHX Text 7.5%
AutoCAD SHX Text 7.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text T
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text
SECTION C-C
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 7.5% Max
AutoCAD SHX Text T
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text
SECTION B-B
AutoCAD SHX Text Depress entire sidewalk as required
AutoCAD SHX Text
ROUNDED
AutoCAD SHX Text
IF NECESSARY
AutoCAD SHX Text
RETAINING CURB
AutoCAD SHX Text T
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 7.5% Max
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text
SECTION A-A
AutoCAD SHX Text
ROUNDED
AutoCAD SHX Text
TOP OF RAMP
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text Max
AutoCAD SHX Text Max
AutoCAD SHX Text
FRONT EDGE OF SIDEWALK
AutoCAD SHX Text
CASE C
AutoCAD SHX Text
RETAINING CURB IF NECESSARY AT EDGE OF SIDEWALK
AutoCAD SHX Text 5'-0" Min
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text 7.5%
AutoCAD SHX Text 7.5%
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text
TYPICAL TWO-RAMP CORNER INSTALLATION
AutoCAD SHX Text
FLARE
AutoCAD SHX Text
FLARE
AutoCAD SHX Text
CROSSWALK IF PROVIDED
AutoCAD SHX Text
CROSSWALK IF PROVIDED
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
LANDING
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text WHERE A FLARED SIDE OCCURS PROVIDE 2'-0" Min OF CURB
AutoCAD SHX Text WHERE A FLARED SIDE OCCURS PROVIDE 2'-0" Min OF CURB
AutoCAD SHX Text
TYPICAL ONE-RAMP CORNER INSTALLATION
AutoCAD SHX Text
DETAIL B
AutoCAD SHX Text
FLARE
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
FLARE
AutoCAD SHX Text Gutter not shown
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 6" Typ
AutoCAD SHX Text
FRONT EDGE OF SIDEWALK
AutoCAD SHX Text
SEE NOTE 8
AutoCAD SHX Text
SEE NOTE 8
AutoCAD SHX Text
TOP OF RAMP
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text
GUTTER FLOWLINE
AutoCAD SHX Text
SEE NOTE 8
AutoCAD SHX Text
GUTTER FLOWLINE
AutoCAD SHX Text
RETAINING CURB IF NECESSARY
AutoCAD SHX Text
GUTTER FLOWLINE
AutoCAD SHX Text See Notes 1 and 3
AutoCAD SHX Text See Note 1
AutoCAD SHX Text 2.3" Min AND 2.4" Max CENTER TO CENTER SPACING
AutoCAD SHX Text 0.2"
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
SEE NOTE 10
AutoCAD SHX Text
SEE NOTE 10
AutoCAD SHX Text
SEE NOTE 10
AutoCAD SHX Text See Note 10
AutoCAD SHX Text
SEE NOTE 10
AutoCAD SHX Text
FRONT EDGE OF SIDEWALK
AutoCAD SHX Text
PLANTING AREA
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text
PLANTING AREA
AutoCAD SHX Text
RETAINING CURB
AutoCAD SHX Text
FRONT EDGE OF SIDEWALK
AutoCAD SHX Text
CASE F
AutoCAD SHX Text
CASE G
AutoCAD SHX Text
RETAINING CURB (BOTH SIDES OF RAMP)
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text 6" Typ
AutoCAD SHX Text 6" Typ
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text 7.5% Max
AutoCAD SHX Text 7.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text See Note 4
AutoCAD SHX Text 9.0% Max AT CURB
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text
SEE NOTE 10
AutoCAD SHX Text
SEE NOTE 10
AutoCAD SHX Text 0.9" Min AND 0.92" Max BASE Dia
AutoCAD SHX Text 0.45" Min AND 0.47" Max TOP Dia
AutoCAD SHX Text
GUTTER PAN TRANSITION
AutoCAD SHX Text
TYPICAL GUTTER PAN APPLIES TO ALL CASES
AutoCAD SHX Text
CURB
AutoCAD SHX Text
PAVEMENT
AutoCAD SHX Text
SEE NOTE 9
AutoCAD SHX Text
SEE NOTE 8
AutoCAD SHX Text
GUTTER IN FRONT OF DETECTABLE
AutoCAD SHX Text
WARNING
AutoCAD SHX Text
SEE NOTE 9
AutoCAD SHX Text
TRANSITION
AutoCAD SHX Text
TRANSITION
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text 6" Min HIGH RETAINING CURB
AutoCAD SHX Text 6" Min HIGH RETAINING CURB
AutoCAD SHX Text
SEE NOTE 10
AutoCAD SHX Text
CURB TO MATCH RAMP SLOPE
AutoCAD SHX Text 3'-0" Typ
AutoCAD SHX Text 3'-0" Typ
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 4'-2" Min
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text
RETAINING CURB (BOTH SIDES OF RAMP)
AutoCAD SHX Text 1.5% Max
AutoCAD SHX Text
1. As site conditions dictate, Case A through Case G curb ramps may be used As site conditions dictate, Case A through Case G curb ramps may be used for corner installations similar to those shown in Detail A and Detail B. The case of curb ramps used in Detail A do not have to be the same. Case A through Case G curb ramps also may be used at mid block locations, as site conditions dictate. For specific site condition configuration, including the conform to existing sidewalk, see Project Plans. 2. If distance from curb to back of sidewalk is too short to accommodate If distance from curb to back of sidewalk is too short to accommodate ramp and 4'-2" platform (landing) as shown in Case A, the sidewalk may be depressed longitudinally as in Case B or C or may be widened as in Case D. 3. When ramp is located in center of curb return, crosswalk configuration must When ramp is located in center of curb return, crosswalk configuration must be similar to that shown for Detail B. 4. As site conditions dictate, the retaining curb side and the flared side of the As site conditions dictate, the retaining curb side and the flared side of the Case G ramp shall be constructed in reversed position. 5. The ramp portion of the curb ramp is a typical rectangle, unless modified in The ramp portion of the curb ramp is a typical rectangle, unless modified in the Project Plans. 6. Side slope of ramp flares vary uniformly from a maximum of 9.0% at curb Side slope of ramp flares vary uniformly from a maximum of 9.0% at curb to conform with longitudinal sidewalk slope adjacent to top of the ramp, except in Case C and Case F. 7. The adjacent surfaces at transitions at curb ramps to walks, gutters, andThe adjacent surfaces at transitions at curb ramps to walks, gutters, andstreets shall be at the same level. 8. Counter slopes of adjoining gutters and road surfaces immediately adjacent Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches of the curb ramp shall not be steeper than 1V:20H (5.0%). Gutter pan slope shall not exceed 1" of depth for each 2'-0" of width. 9. Transition gutter pan slope from 1" of depth for each 2'-0" of width to Transition gutter pan slope from 1" of depth for each 2'-0" of width to match typical gutter pan slope per Standard Plan A87A. 10. The detectable warning surface will be a rectangle as shown at back of The detectable warning surface will be a rectangle as shown at back of curb, unless modified in the Project Plans. Curb ramps shall have a detectable warning surface that extends the full width and 3'-0" depth of the ramp. Detectable warning surfaces shall extend the full width of the ramp except a maximum gap of 1 inch is allowed on each side of the ramp. Detectable warning surfaces shall conform to the requirements in the Standard Specifications. 11. Sidewalk and ramp thickness, "T", shall be 3 1/2" minimum. Sidewalk and ramp thickness, "T", shall be 3 1/2" minimum. 12. Utility pull boxes, manholes, vaults and all other utility facilities within the Utility pull boxes, manholes, vaults and all other utility facilities within the boundaries of the curb ramp will be relocated or adjusted to grade by the owner prior to, or in conjunction with, curb ramp construction. 13. Detectable warning surface may have to be cut to allow removal of utility Detectable warning surface may have to be cut to allow removal of utility covers while maintaining detectable warning width and depth.
AutoCAD SHX Text
2018 STANDARD PLAN A88A
AutoCAD SHX Text 1-29-18
AutoCAD SHX Text A88A
AutoCAD SHX Text A
AutoCAD SHX Text A
STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION CURB RAMP DETAILS NO SCALE
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
DETAIL SHEET
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 NO SCALE
13 14
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text T
AutoCAD SHX Text Var
AutoCAD SHX Text Min
AutoCAD SHX Text
SECTION B-B
AutoCAD SHX Text
RETAINING CURB
AutoCAD SHX Text
CLEAR PASSAGEWAY
AutoCAD SHX Text 6"
AutoCAD SHX Text Typ
AutoCAD SHX Text
IF NECESSARY
AutoCAD SHX Text T
AutoCAD SHX Text
RETAINING CURB
AutoCAD SHX Text
SECTION A-A
AutoCAD SHX Text
AutoCAD SHX Text
GUTTER
AutoCAD SHX Text
FLOWLINE
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text Max
AutoCAD SHX Text
IF NECESSARY, CONSTRUCT RETAINING
AutoCAD SHX Text
CURB AT EDGE OF SIDEWALK
AutoCAD SHX Text
CASE CM CURB RAMP
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text
BCR
AutoCAD SHX Text
CROSSWALK
AutoCAD SHX Text
IF PROVIDED
AutoCAD SHX Text 6"
AutoCAD SHX Text Typ
AutoCAD SHX Text
TRAVELED WAY
AutoCAD SHX Text
TRAVELED WAY
AutoCAD SHX Text Min
AutoCAD SHX Text Min
AutoCAD SHX Text
RAISED ISLAND
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
TYPE B PASSAGEWAY
AutoCAD SHX Text
SLOPE PASSAGEWAY
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text TO DRAIN 1.5%%% Max
AutoCAD SHX Text 1.5%%% Max
AutoCAD SHX Text 1.5%%%
AutoCAD SHX Text Max
AutoCAD SHX Text 7.5%%%
AutoCAD SHX Text 1.5%%% Max
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text
SURFACE OF
AutoCAD SHX Text
RAISED ISLAND
AutoCAD SHX Text 5'-0" Min
AutoCAD SHX Text
IF CROSSWALK
AutoCAD SHX Text
PROVIDED
AutoCAD SHX Text Gutter not shown
AutoCAD SHX Text
CROSSWALK
AutoCAD SHX Text
IF PROVIDED
AutoCAD SHX Text 1.5%%%
AutoCAD SHX Text Max
AutoCAD SHX Text
SEE NOTE 3
AutoCAD SHX Text
SEE NOTE 3
AutoCAD SHX Text
SEE NOTE 7
AutoCAD SHX Text Min
AutoCAD SHX Text Min
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
TYPE C PASSAGEWAY
AutoCAD SHX Text Min
AutoCAD SHX Text
RAISED ISLAND
AutoCAD SHX Text
TRAVELED WAY
AutoCAD SHX Text
TRAVELED WAY
AutoCAD SHX Text
SLOPE PASSAGEWAY
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text TO DRAIN 1.5%%% Max
AutoCAD SHX Text
SEE NOTE 3
AutoCAD SHX Text
SEE NOTE 3
AutoCAD SHX Text
SEE NOTE 3
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
CURB RAMP,
AutoCAD SHX Text
SEE NOTE 7
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
CURB RAMP,
AutoCAD SHX Text
SEE NOTE 7
AutoCAD SHX Text Min
AutoCAD SHX Text
TYPE A PASSAGEWAY
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
RAISED ISLAND
AutoCAD SHX Text
TRAVELED WAY
AutoCAD SHX Text
TRAVELED WAY
AutoCAD SHX Text
RAISED ISLAND
AutoCAD SHX Text 4'-2"
AutoCAD SHX Text
SEE NOTE 3
AutoCAD SHX Text
SEE NOTE 3
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
PASSAGEWAY
AutoCAD SHX Text
TO DRAIN
AutoCAD SHX Text 1.5%%% Max
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
CURB RAMP,
AutoCAD SHX Text
SEE NOTE 7
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
CURB RAMP,
AutoCAD SHX Text
SEE NOTE 7
AutoCAD SHX Text Max
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text Min
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text 7.5%%%
AutoCAD SHX Text 1.5%%% Max
AutoCAD SHX Text 1.5%%% Max
AutoCAD SHX Text 1.5%%%
AutoCAD SHX Text Max
AutoCAD SHX Text 6"
AutoCAD SHX Text Typ
AutoCAD SHX Text
CASE CH CURB RAMP
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text 6" Min HIGH
AutoCAD SHX Text
RETAINING CURB
AutoCAD SHX Text
CURB TO MATCH
AutoCAD SHX Text
RAMP SLOPE
AutoCAD SHX Text 6" Min HIGH
AutoCAD SHX Text
RETAINING CURB
AutoCAD SHX Text
IF NECESSARY, CONSTRUCT RETAINING
AutoCAD SHX Text
CURB AT EDGE OF SIDEWALK
AutoCAD SHX Text
DETECTABLE WARNING
AutoCAD SHX Text
SURFACE, SEE NOTE 2
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
CURB
AutoCAD SHX Text
CROSSWALK
AutoCAD SHX Text
IF PROVIDED
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
CURB RAMP,
AutoCAD SHX Text
SEE NOTE 7
AutoCAD SHX Text
DETECTABLE
AutoCAD SHX Text
WARNING
AutoCAD SHX Text
SURFACE,
AutoCAD SHX Text
SEE NOTE 2
AutoCAD SHX Text
TRANSITION
AutoCAD SHX Text
FROM FULL
AutoCAD SHX Text
HEIGHT TO
AutoCAD SHX Text
ZERO HEIGHT
AutoCAD SHX Text
CURB
AutoCAD SHX Text
SIDEWALK
AutoCAD SHX Text
CURB RAMP,
AutoCAD SHX Text
SEE NOTE 7
AutoCAD SHX Text
CURB TO MATCH
AutoCAD SHX Text
RAMP SLOPE
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text 1.5%%% Max
AutoCAD SHX Text 1.5%%% Max
AutoCAD SHX Text
DETECTABLE
AutoCAD SHX Text
WARNING
AutoCAD SHX Text
SURFACE,
AutoCAD SHX Text
SEE NOTES 2
AutoCAD SHX Text
AND 8
AutoCAD SHX Text
DETECTABLE
AutoCAD SHX Text
WARNING
AutoCAD SHX Text
SURFACE,
AutoCAD SHX Text
SEE NOTES 2
AutoCAD SHX Text
AND 8
AutoCAD SHX Text
DETECTABLE
AutoCAD SHX Text
WARNING
AutoCAD SHX Text
SURFACE,
AutoCAD SHX Text
SEE NOTES 2
AutoCAD SHX Text
AND 8
AutoCAD SHX Text 6'-0"
AutoCAD SHX Text Min
AutoCAD SHX Text
2018 STANDARD PLAN A88B
AutoCAD SHX Text 1-29-18
AutoCAD SHX Text A88B
AutoCAD SHX Text
1. Sidewalk, ramp and passageway thickness, "T", shall be 31/2" minimum. Sidewalk, ramp and passageway thickness, "T", shall be 31/2" minimum. 2. For details of detectable warning surfaces, see Standard Plan A88A. For details of detectable warning surfaces, see Standard Plan A88A. 3. Where an island passageway length is greater than or equal to 6'-0", but Where an island passageway length is greater than or equal to 6'-0", but less than 8'-0", each detectable warning surface shall extend the full width and 2'-0" depth of the passageway length. Where an island passageway length is greater than or equal to 8'-0", each detectable warning surface shall extend the full width and 3'-0" depth of the passageway length. Detectable warning surfaces shall extend the full width of the island passageway except a maximum gap of 1 inch is allowed on each side of the passageway. 4. The adjacent surfaces at transitions at curb ramps to walks, gutters, and The adjacent surfaces at transitions at curb ramps to walks, gutters, and streets shall be at the same level. 5. Utility pull boxes, manholes, vaults and all other utility facilities within the Utility pull boxes, manholes, vaults and all other utility facilities within the boundaries of the curb ramp will be relocated or adjusted to grade by the owner prior to, or in conjunction with, curb ramp construction. 6. Detectable warning surface may have to be cut to allow removal of utility Detectable warning surface may have to be cut to allow removal of utility covers while maintaining detectable warning width and depth. 7. For additional curb ramp details, see Standard Plan A88A. For additional curb ramp details, see Standard Plan A88A. 8. The detectable warning surface will be a rectangle as shown at the face The detectable warning surface will be a rectangle as shown at the face of curb, unless modified in the Project Plans.
STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION CURB RAMP AND ISLAND PASSAGEWAY DETAILS NO SCALE
FIELD BOOK:
DESIGN
CHECKED
DATE
DRAWN
VAULT NO.
SCALE
SHEET OF
809 Center Street, Room 201 Santa Cruz, CA 95060
REVISIONS
P U B L I C W O R K S D E P A R T M E N T
C I T
Y
O F S A N T A C R
U Z
C
A L I F O R N
I
A
QUANTITY SHEET
UNSIGNALIZED CROSSING IMPROVEMENT PROJECT
HSIP CYCLE 11 & 12
DnC
DE
DnC
10/13/2026 NO SCALE
14 14
I A
RE
EN
I
GN
E L
V I LIC
ACF FIL OR
NSEF IS O
N
A
ETA
RP
E
TS
I G E R
ETS
R
D
O
O
No. C 088069
EXP. 3/31/28
QUANTITY
LAUREL ST -
BLACKBURN ST
BROADWAY -
PENNSYLVANIA AVE
SEABRIGHT AVE -
LOGAN ST
HIGH ST - CARDIFF
PL
SOQUEL AVE -
POPLAR AVE
RRFB ASSEMBLY
Install (N) RRFB Solar Assembly EA 3 2 2 5 5
Install (N) RRFB Light Bar EA 4 4 4 4 5 Install (N) Pedestrian Push Button EA 3 2 2 5 5
Install Pull Box (Caltrans #3-1/2) EA 1 2 0 0 2
Install Conduit and Conductors LF 20 24 0 0 30
POSTS
Install (N) City Standard Post EA 0 2 2 6 2 Remove (E) City Standard Post EA 3 2 1 6 5
Install (N) Type 1B Post (4 In. NPS) EA 1 2 1 1 0 Install (N) Combined Push Button Post (2.5 In. NPS) EA 2 0 0 3 5 Install (N) Pedestrian Push Button Post (2.5 In. NPS) EA 1 2 0 0 2
SIGNS
Relocate (E) Sign EA 9 8 4 4 10 Remove (E) Sign EA 0 0 0 4 2 Install (N) N-5 (CA) Object Marker Sign (24" x 24") EA 0 0 0 1 0 Install (N) R10-25 Sign (5" x 7") EA 3 2 2 5 5
Install (N) W11-15 Sign (Ped/Bike Crossing) (30" x 30") EA 0 0 0 6 0
Install (N) W11-2 Sign (Ped. Crossing) (30" x 30") EA 0 0 2 0 0
Install (N) W16-7P(R) Sign (Directional Arrow) (30" x 18") EA 0 0 2 0 0 Install (N) W16-7P(L&R) Sign (Directional Arrow) (30" X 18") EA 0 0 0 2 1 Install (N) W16-9P Sign (Ahead) (30" x 18") EA 0 0 0 2 0 Install (N) R1-5 Sign (Yield Here) (24" x 24") EA 0 2 2 2 1
| Sheet 01R |
| Sheet 02R |
| Sheets and Views |
| HSIP11-rev5D-02-Notes |
| Sheet 03R |
| Sheets and Views |
| HSIP11-rev5D-03-Laurel-Blackburn |
| Sheet 04R |
| Sheets and Views |
| HSIP11-rev5D-04-Broadway-Penn |
| Sheet 05R |
| Sheets and Views |
| HSIP11-rev5D-05-Broadway-Penn Detail |
| Sheet 06R |
| Sheets and Views |
| HSIP11-rev5D-06-Seabright-Logan (2) |
| Sheet 07R |
| Sheets and Views |
| HSIP11-rev5D-07-High-Cardiff |
| Sheet 08R |
| Sheets and Views |
| HSIP11-rev5D-08-High-Cardiff Detail |
| Sheet 09R |
| Sheets and Views |
| HSIP11-rev5D-09-Soquel-Poplar |
| Sheet 10R |
| Sheets and Views |
| HSIP11-rev5D-10-Soquel-Poplar Detail |
| Sheet 11R |
| Sheets and Views |
| HSIP11-rev5D-11-Detail |
| Sheet 12R |
| Sheets and Views |
| HSIP11-rev5D-12-Detail |
| Sheet 13R |
| Sheets and Views |
| HSIP11-rev5D-13-Detail |
| Sheet 14R |
| Sheets and Views |
| HSIP11-rev5D-14-Quantity |
File details come from the government source that posted it. Updated .