Attachment_3_RBPR_Matrix_2nd_Half_.xlsx

XLSX spreadsheet 514 KB Posted

Attached to
Manufactured Housing Units Federal contract opportunity
Solicitation number
HSFE70-14-R-0005
Issued by
Federal Emergency Management Agency Logistics Section

About this file

Second Half of Attachment 3 in Excel format

View the file

Other files for this federal contract opportunity

Other files attached to Manufactured Housing Units, newest first.
File Type Posted
Attachment_2_F_R_B_Performance_Requirements__versionBB_23July2014.pdf PDF
HSFE70-14-R-0005_A00003.pdf PDF
MHU_Solictation_QA_Comment_Matrix_18_Jul_14.xlsx XLSX spreadsheet
Attachment_16_Section_E_MHU_Quality_Assurance_Plan_18Jul2014.pdf PDF
HSFE70-14-R-0005_Solicitation_A00002_.pdf PDF
Attachment_2_F_R_B_Performance_Requirements__versionBB_18July2014_1600_.pdf PDF
Attachment_3_FEMA_Rugged_Based_Performance_Requirements_Matrix_18July2014_1600.docx DOCX document
HSFE70-14-R-0005_A00002.pdf PDF
Responses_to_Draft_RFP_Comments_HSFE70-14-R-0005.pdf PDF
HSFE70-14-R-0005_A00001.pdf PDF
Attachment_20_Reference_Table.pdf PDF
Attachment_2_F_R_B_Performance_Requirements__versionBB.pdf PDF
Attachment_16_Section_E_MHU_Quality_Assurance_Plan.pdf PDF
Attachment_7_Delivery_Schedule_Template.xlsx XLSX spreadsheet
Attachment_17_MHU_sizing_table_for_Section_L.pdf PDF
Attachment_4_MHU_First_Article_Testing_Inspection_Checklist.xlsx XLSX spreadsheet
HSFE70-14-R-0005_Solicitation.pdf PDF
Attachment_6_MFG_shipment_sheet.xlsx XLSX spreadsheet
Attachment_8_Unit_Production_Report.xlsx XLSX spreadsheet
Attachment_12_Warranty_Repairs_In_The_Field_List.xlsx XLSX spreadsheet
Attachment_15_Comment_Matrix_.xlsx XLSX spreadsheet
Attachment_11_Design_Details_for_Accessible_Disaster_Relief_Housing_Guide.pdf PDF
Attachment_9_Invoice-Sample_Summary.pdf PDF
Attachment_19_MHU_Idenfication_Number_Summary.pdf PDF
Attachment_10_Production_Facility_Inspection_Report.pdf PDF
Attachment_13_Acronyms_and_Definitions.pdf PDF
Attachment_5_Manufactured_Home_Acceptance_Inspection_List.xlsx XLSX spreadsheet
Attachment_18_Minimum_Essential_Requirements.pdf PDF
Attachment_1_-_Pricing.xlsx XLSX spreadsheet
Attachment_3_FEMA_Rugged_Base_Performance_Requirements_Matrix.pdf PDF
Attachment_14_MHU_Past_Perofrmance_Questionnaire.pdf PDF
Attachment_3_HSFE70-14-R-0005_Requirement_Matrix.pdf PDF
Attachment_9_Invoice-Sample_Summary.docx DOCX document
Attachment_8Unit_Production_Report.xlsx XLSX spreadsheet
Attachment_2_F_R_B_Performance_Requirements__19dec2013_1517.docx DOCX document
Attachment_10_Production_Facility_Inspection_report.docx DOCX document
Section_B_CLIN_Table_and_Small_Business_Scenarios_1c_and_1d_01312014_1108_hrs.xlsx XLSX spreadsheet
HSFE70-14-R-0005_draft_Sol-2-6-14.pdf PDF
Attachment_11_Design_Details_for_Accessible_Disaster_Relief_Housing_Guid....pdf PDF
Attachment_7_Delivery_Schedule_Template.xlsx XLSX spreadsheet
Attachment_6_MFG_shipment_sheet.xlsx XLSX spreadsheet
Attachment_13_Acronyms_and_Definitions_17dec2013.docx DOCX document
Attachment_12_Chargeback_List_06Dec2013_1510_hrs.xlsx XLSX spreadsheet
MHU_PPQ_Form_12-18.docx DOCX document
Attachment_4_MHU_First_Article_Testing_Inspection_Checklist.xlsx XLSX spreadsheet
Attachment_15_Comment_Matrix_.xlsx XLSX spreadsheet
Attachment_5_Manufactured_Home_Acceptance_Inspection_List_19dec2013.xlsx XLSX spreadsheet
Section_B_CLIN_Table_and_Non_Small_Business_Scenarios_1a_and_1b__06022014.xlsx XLSX spreadsheet
Synopsis_For_MHU_Long_Term_1-8-14.pdf PDF
Show all 49

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

FEMA REQUIREMENT MATRIX
SectionFEMA Requirement:FEMA Requirement complianceRequirement metDescriptionLocationFEMA acceptance
(“shall(#)”).
Yes , No or N/A
1.0. Compliance With 24 CFR 3280
1.1 Compliance with 24 CFR 3280 (a.k.a. “HUD Code”)All units shall (1) be built to HUD Code as defined in 24 CFR 3280 & 3282.3 bedroom
2 bedroom
1 bedroom
Express unit
All units shall (2) bear the HUD label prior to shipment, …3 bedroom
2 bedroom
1 bedroom
Express unit
shall (3) meet any solicitation-specific HUD defined ratings for Wind Zone, Thermal Zone, and Roof Load.3 bedroom
2 bedroom
1 bedroom
Express unit
2.0 Compliance with International Building Code
2.1 International Building Code (IBC)Each unit shall (4) include full house wrap meeting the standards set forth in the 2009 International Building Code, Section 1403.2 Weather Protection.3 bedroom
2 bedroom
1 bedroom
Express unit
3.0 Compliance with Uniform Accessibility Standards(UFAS)
3.1 Uniform Federal Accessibility Standards (UFAS)All units designated as “UFAS” or “Accessible” shall (5) be fully compliant with UFAS and this document. UFAS “reminders” included throughout these requirements are used to highlight certain standards, but are not all-inclusive,…3 bedroom
2 bedroom
1 bedroom
Express unit
…the contractor shall (6) be responsible for ensuring full compliance with applicable UFAS requirements. Units designated as UFAS shall(6a) meet the Final Guidelines for Emergency Transportable Housing(36 CFR Part 1191)3 bedroom
2 bedroom
1 bedroom
Express unit
4.0 Zoning Requirements
4.1“FEMA Northern Units” Manufactured Housing Design Criteria shall (7) be in Accordance with 24 CFR 3280.506 Thermal Zone 3 ( a U-Value for Zone 3)3 bedroom
2 bedroom
1 bedroom
Express unit
4.1.1Thermal Identification shall (8) have a Painted Blue Draw Bar3 bedroom
2 bedroom
1 bedroom
Express unit
4.2FEMA “Southern Units” Manufactured Housing Design Criteria shall (9) be in Accordance with 24 CFR 3280.506 for Thermal Zone 2 (U-Value for Zone 2)…3 bedroom
2 bedroom
1 bedroom
Express unit
4.2.1Thermal Identification shall (10) have a Painted Red Draw Bar3 bedroom
2 bedroom
1 bedroom
Express unit
4.3FEMA “CONUS” unit shall (11) be able to be deployable in Contiguous United States.3 bedroom
2 bedroom
1 bedroom
Express unit
4.3.1Thermal Identification shall (12) have a painted Green Draw Bar3 bedroom
2 bedroom
1 bedroom
Express unit
4.4FEMA Units” (all) Manufactured Housing Design Criteria shall (13) be in Accordance with 24 CFR 3280.305(c) Structural design requirements - Wind, snow and roof loads for Wind Zone III.3 bedroom
2 bedroom
1 bedroom
Express unit
4.5“FEMA Units” (all expect Southern units), Manufactured Housing Design Criteria shall (14) be in Accordance with 24 CFR 3280.305(c) Structural design requirements – roof load Northern Zone3 bedroom
2 bedroom
1 bedroom
Express unit
5..0 Size and Configuration
5.1 Exterior LengthFinal dimensions shall (15) be proposed by contractor, but not to exceed sixty feet(60’)(box length)3 bedroom
2 bedroom
1 bedroom
Express unit
Final dimensions shall (16) be proposed by contractor3 bedroom
2 bedroom
1 bedroom
Express unit
1 bed Final dimensions shall (17) be proposed by contractor3 bedroom
2 bedroom
1 bedroom
Express unit
Final dimensions shall (18) be proposed by contractor, but not less than forty four (44) feet and not to exceed forty eight ( 48’) feet (box length)3 bedroom
2 bedroom
1 bedroom
Express unit
5.2 Exterior Width3 bed -Final Dimensions shall (19) not exceed fourteen feet (14’) (box width)3 bedroom
2 bedroom
1 bedroom
Express unit
2 bed Final dimensions shall (20) be proposed by contractor, but not to exceed fourteen feet (14’)(box width)3 bedroom
2 bedroom
1 bedroom
Express unit
1 bed Final dimensions shall (21) be proposed by contractor, but not to exceed fourteen feet (14’)(box width)3 bedroom
2 bedroom
1 bedroom
Express unit
Express: Final dimensions shall l(22) be proposed by the contractor, but not be less than eight (8’) and not to exceed eight and one half feet (8.6’) (transport width) Slide out portions of the MHU are not acceptable3 bedroom
2 bedroom
1 bedroom
Express unit
5.3 AreaAcceptable manufactured home size (Area) for the 3-Bedroom units shall (23) be a maximum of eight-hundred forty square feet (840 sq. ft.)3 bedroom
2 bedroom
1 bedroom
Express unit
Acceptable manufactured home size (Area) for the 2-Bedroom units shall (24) be a maximum of seven-hundred forty square feet (740 sq. ft.)3 bedroom
2 bedroom
1 bedroom
Express unit
Acceptable – manufactured home size for the 1- Bedroom units shall (25) be a maximum of five-hundred seventy-five square feet (575 sq. ft.)3 bedroom
2 bedroom
1 bedroom
Express unit
Acceptable manufactured home size (area) for the express unit shall (26) be between a minimum of three hundred and fifty two square feet (352 sq. ft.) and a maximum of four hundred and eight square feet (408 sq. ft.)(Refer to 5.4)3 bedroom
2 bedroom
1 bedroom
Express unit
5.4 Express unitExpress units shall (26a) be transportable without permits (24/7). The maximum height of the units shall (26b) be 13’ 6”.
6.0 Living Room
6.1 FurnishingEach unit shall (27) have a designated, usable living room area.3 bedroom
2 bedroom
1 bedroom
Express unit
Each living room area shall(28) be furnished with one (1) sofa (For Express units, a Loveseat as an alternative will meet the requirement)), one (1) armchair (constructed of non-permeable material such as wood, without fabric covering), one (1) coffee table, and one (1) end table.3 bedroom
2 bedroom
1 bedroom
Express unit
All furnishing shall (29) be standard sizes and commercially available.3 bedroom
2 bedroom
1 bedroom
Express unit
All furniture shall (30) be assembled with all packing material removed from the manufactured home.3 bedroom
2 bedroom
1 bedroom
Express unit
Furniture shall (31) be packed in a manner so that it is not damaged during multiple transportations and/or in the unpacking process.3 bedroom
2 bedroom
1 bedroom
Express unit
Quality furniture requires good construction (i.e., free of defects) and the sofa shall (32) be soft, comfortable (provide comfort or physical relief, free of causing affliction or pain to the occupant), safe, be free of sharp, abrasive surfaces, edges and durable for up to five (5) years in storage and/or eighteen (18) months during occupancy.3 bedroom
2 bedroom
1 bedroom
Express unit
All fabric or material used shall (33) sustain rough and tumble usage.3 bedroom
2 bedroom
1 bedroom
Express unit
Fabric or material shall (34) meet the federal flammability standards.3 bedroom
2 bedroom
1 bedroom
Express unit
All fabric or material shall (35) have stain resistance protection and sustain rough and tumble usage3 bedroom
2 bedroom
1 bedroom
Express unit
6.2 Telephone and cable television outletsCable Television Jack: Each unit shall (36) have a pre-wired television jack installed in the living room.3 bedroom
.2 bedroom
1 bedroom
Express unit
The cable jack shall (37) be wired to a designated junction box for easy connection by a service provider.3 bedroom
2 bedroom
1 bedroom
Express unit
Telephone Jack: Each unit shall (38) have a pre-wired telephone jack installed in the living room.3 bedroom
2 bedroom
1 bedroom
Express unit
The telephone jack shall (39) be wired for two lines or a telephone jack with double outlets.3 bedroom
2 bedroom
1 bedroom
Express unit
The telephone jack shall (40) be wired to a designated junction box for easy connection by a service provider.3 bedroom
2 bedroom
1 bedroom
Express unit
Cable and television jacks shall (41) be placed so that when the wires are plugged in it does not interfere with the usability of the unit and any safety issues such as trip hazards are avoided. At the same time, the jacks shall (42) be placed in a matter that furniture does not have to be moved to access the cable, and telephone jacks.3 bedroom
2 bedroom
1 bedroom
Express unit
7.0 Kitchen/ Dining Room
7.1 FurnishingEach unit shall (43) have a designated safe and usable kitchen/dining room area.3 bedroom
2 bedroom
1 bedroom
Express unit
3 bedroom
The dining room area shall (44) be furnished with dinette table.2 bedroom
1 bedroom
Express unit
The table shall (45) accommodate all chairs listed for the table size below without any extensions or folding portions of the table having to be open (table sizes are listed as the minimum acceptable size.)3 bedroom
2 bedroom
1 bedroom
Express unit
Furnishing designated for the dining area shall (46) not have any porous fabric material3 bedroom
2 bedroom
1 bedroom
Express unit
Furniture for the dining area shall (47) be composed of wood.3 bedroom
2 bedroom
1 bedroom
Express unit
All dining room area furniture shall (48) be assembled with all packing material removed from the manufactured home.3 bedroom
2 bedroom
1 bedroom
Express unit
All dining room area furniture shall (49) be secured in a manner so that it is not damaged during multiple transportations or in the unpacking process.3 bedroom
2 bedroom
1 bedroom
Express unit
3 bed- Furniture shall (50) be one (1) table, sized approx. 3’ x 6’6”, with six (6) chairs to accommodate six (6) adults3 bedroom
2 bedroom
Note: All chairs shall be the same size and matched1 bedroom
Express unit
2 bed - Furniture shall (51) be one (1) table, sized approx. 3’ x 5’, with four (4) chairs to accommodate four (4) adults3 bedroom
2 bedroom
Note: All chairs shall be the same size and matched1 bedroom
Express unit
1 bed - Furniture shall (52) be one (1) table, sized approx. 3’ x 5’, with four (4) chairs to accommodate four (4) adults3 bedroom
Note: All chairs shall be the same size and2 bedroom
matched1 bedroom
Express unit
Express- Furniture shall (53) be one (1) table, approx. sized 3’ x 5’, with four (4) chairs to accommodate four (4) adults3 bedroom
Note: All chairs shall
be the same size and2 bedroom
matched1 bedroom
Express unit
7.2 CabinetryThe manufacturer shall(54) provide and install upper and lower cabinets3 bedroom
2 bedroom
1 bedroom
Express unit
Cabinets upper and lower shall (55) be equal to or better than Kitchen Cabinet Manufacturers Association (KCMA) certified cabinets.3 bedroom
2 bedroom
The contractor have the option to perform self-certification (The contractor shall indicate in the Attachment 3 how the cabinets chosen or built will perform equal or better than the KCMA certified cabinets1 bedroom
Express unit
3 bedroom
The minimum acceptable linear feet length for the upper (wall) cabinet shall(56) be 3 feet2 bedroom
1 bedroom
Express unit
The manufacturer shall (57)explore the option of adding additional upper (wall) cabinets, additional upper cabinets are desirable.3 bedroom
2 bedroom
1 bedroom
Express unit
The minimum acceptable linear feet length for the lower cabinet shall(58)be 3 feet 0 inches.3 bedroom
2 bedroom
1 bedroom
Express unit
An acceptable lower cabinet shall (59) have a single drawer and two doors.3 bedroom
2 bedroom
1 bedroom
Express unit
The manufacturer shall (60) explore the option of adding additional lower cabinets, additional lower cabinets are desirable.3 bedroom
2 bedroom
1 bedroom
Express unit
The upper and lower cabinets shall (61) have fixed shelving.3 bedroom
2 bedroom
1 bedroom
Express unit
All cabinets shall (62) be constructed with a finish compatible with the interior decor3 bedroom
2 bedroom
1 bedroom
Express unit
7.3 Kitchen Counter TopsThe Manufacturer shall (63) install post formed laminated counter top(the counter top formed from a single piece of laminate that's shaped into a backsplash at the rear and a rounded drip edge in front) or shall (64) be an industry standard countertop with a back splash property sealed and water resistant to last for both, storage (nominal 5 years) and use (1-2 years).3 bedroom
2 bedroom
1 bedroom
Express unit
The minimum size of the backsplash height shall (65) be 4 inches above the finished surface of the counter top.3 bedroom
2 bedroom
1 bedroom
Express unit
All units shall (66) include a minimum of thirty-six inches (36”) of continuous counter top space in the kitchen supported by a base cabinet that has a single drawer and two doors.3 bedroom
2 bedroom
1 bedroom
Express unit
Kitchen space shall (67) accommodate food preparation.3 bedroom
2 bedroom
1 bedroom
Express unit
Access to counter top shall (68) be unobstructed.3 bedroom
2 bedroom
1 bedroom
Express unit
All surfaces subject to food preparation shall (69) be washable, without open joints or comprised of materials that cannot be sanitized and/or are not suited for long term use3 bedroom
2 bedroom
1 bedroom
Express unit
7.4 Kitchen SinkEach home shall (70) have a completely installed, self-rimming, double bowl, stainless steel sink with a faucet that have a one spray nozzle with at least twenty- four inch (24”) extension when extended.3 bedroom
2 bedroom
1 bedroom
Note: For express units a standard size commercially available single basin Kitchen sink will meet the requirement.Express unit
Each sink bowl shall (71) be fitted with a metal strainer basket assembly and an appropriately sized strainer basket.3 bedroom
2 bedroom
1 bedroom
Note: For express units a standard size commercially available single basin Kitchen sink will meet the requirement.Express unit
Kitchen sink shall (72) be a minimum of:3 bedroom
33"L x 22"H
Basin depth: 8"
Double equal basins2 bedroom
1 bedroom
Note: For express units a standard size commercially available single basin Kitchen sink will meet the requirement.Express unit
Hot water and drain pipes shall (73) be insulated to protect against contact unless they are contained in a kitchen sink base cabinet.3 bedroom
2 bedroom
1 bedroom
Express unit
Kitchen pipes and fixtures shall (74) have the adequate protection and insulation to avoid causing injuries whether the manufactured home is occupied or not.3 bedroom
2 bedroom
1 bedroom
Express unit
Kitchen pipes and fixtures shall (75) have the adequate protection and insulation to avoid freezing.3 bedroom
2 bedroom
1 bedroom
Note: All faucet assemblies in the home shall (143) include secondary shutoff valves (one for each, the hot and cold water supply).Express unit
There shall (76) be no sharp or abrasive surfaces under the kitchen sink.3 bedroom
2 bedroom
1 bedroom
Express unit
7.5 AppliancesThe Contractor shall (77) ensure that all appliances are high-efficiency and Energy Star qualified (The US Department of Energy list of appliances with Energy Star ratings)3 bedroom
2 bedroom
1 bedroom
Express unit
The Contractor shall (78) leave in place all labels that are affixed to the appliances and which designate that the appliances are high-efficiency and/or Energy Star qualified.3 bedroom
2 bedroom
1 bedroom
Express unit
All appliances shall (79 )be unpacked, installed and packing material shall (80) be removed from the manufactured home.3 bedroom
2 bedroom
1 bedroom
Express unit
All appliances shall (81) be secured in a manner so that it is not damaged during multiple transportations or interfere when the unit is occupied.3 bedroom
2 bedroom
1 bedroom
Express unit
Items used to secure appliance doors shall (82) be easily removed (i.e., refrigerator door, oven door)3 bedroom
2 bedroom
1 bedroom
Express unit
7.5.1 Range/OvenThe contractor shall (83) install a thirty inch (30”) self-cleaning electric cooking range / oven.3 bedroom
2 bedroom
1 bedroom
For express units: 24 in is acceptable, 30 in is preferredExpress unit
It shall (84) include four (4) burners, a thermostatically controlled lighted oven, and indicator lights that show that the burners are operating or are hot3 bedroom
2 bedroom
1 bedroom
For express units: 3 burners is acceptable, 4 burners is preferred.Express unit
Range / oven controls shall (85) be located so that the user does not have to reach across burners to use the range / oven.3 bedroom
2 bedroom
1 bedroom
Express unit
The oven shall (86) have insulation on all sides to prevent excessive heat exposure.3 bedroom
2 bedroom
1 bedroom
Express unit
The range / oven shall (87) be secured to the floor to ensure that it is not damaged during multiple transportations, affects the structure of the MHU, interfere when the unit is occupied, compromise safety of the occupants or becomes damaged or damage the MHU unit during transportation.3 bedroom
2 bedroom
1 bedroom
Express unit
The range/oven shall (88) be secured using a minimum of two brackets.3 bedroom
2 bedroom
1 bedroom
Express unit
The range / oven shall (89) be plugged into the receptacle (receptacle for range is flush mounted in the wall behind range). Brackets used can include the typical angle bracket / gusset that supplied with a range / oven and an additional angle bracket / gusset.3 bedroom
2 bedroom
1 bedroom
Express unit
7.5.2 Power Vented RangeA lighted, power-vented range hood shall (90) be installed (one-piece construction) unless a combination microwave / hood / fan / light is installed.3 bedroom
2 bedroom
1 bedroom
Express unit
7.5.3 RefrigeratorEach unit shall (91) be equipped an 18 cubic feet (c.f.) or equivalent frost-free refrigerator with freezer3 bedroom
2 bedroom
1 bedroom
For the express unit 12 cubic feet (c.f.) refrigerator is acceptable, 18 (c.f.) preferred.Express unit
The refrigerator shall (92) be secured to the floor. Also, the refrigerator shall (93) be secured at least to one wall stud.3 bedroom
2 bedroom
1 bedroom
Express unit
The refrigerator shall (94) be on its own receptacle and in a dedicated circuit.3 bedroom
2 bedroom
1 bedroom
Express unit
.The refrigerator shall (95) be located in the kitchen area inside of the MHU. The refrigerator shall (96) be located so that when the door swings open it does not impede access when approaching from the stove, sink, and food preparation area3 bedroom
2 bedroom
1 bedroom
Express unit
3 bedroom
The refrigerator shall (97) not be plugged in at time of delivery to FEMA.2 bedroom
1 bedroom
Express unit
7.5.4 Microwave OvenEach unit shall (98) include a 1.2 c.f. microwave (minimum) with child lock unless this requirement is met through the use of a combination microwave / hood / fan / light3 bedroom
2 bedroom
1 bedroom
Express unit
7.6 Laundry Area, Washer and dryer hook upAll Manufactured Homes shall (99) have a laundry area designated for the washer and dryer including the plumbing, electrical connections, and dryer vent.3 bedroom
2 bedroom
1 bedroom
Express unit
3 bedroom
The washer / dryer area shall (100) be designed to accommodate a standard size side by side washer/dryer (i.e., 27" wide, 36" high and extends from the wall 29 inches).
Note: For express units, the washer and dryer designated area has to be for side by side Washer and Dryer unless the Offeror can demonstrate that there is a significant commercial market that produces stackable washer/dryer combination that are UFAS/ADA compliant; however they can be (24” to 25” wide) units, under or not under the counter.2 bedroom
1 bedroom
Express unit
The Dryer vent shall (101) have an exhaust to the exterior so that when connecting the dryer duct, the dryer exhaust to the outside.3 bedroom
2 bedroom
1 bedroom
Express unit
The Dryer exhaust system shall (102) not terminate under the home.3 bedroom
2 bedroom
1 bedroom
Express unit
3 bedroom
The Washer and Dryer hookup shall (103) not require any modification to install a washer and/or dryer.2 bedroom
1 bedroom
Express unit
The manufactured home shall (104) not include a washer and dryer3 bedroom
2 bedroom
1 bedroom
Express unit
8.0 Bedrooms
8.1 FurnishingAll units shall (105) provide sleeping capacity to accommodate two persons in each bedroom.3 bedroom
2 bedroom
1 bedroom
Express unit
On the floor plan the bedrooms shall (106) be designated as follows:3 bedroom
· Master bedroom – Bedroom 1
· Second bedroom – Bedroom 2
· Third bedroom – Bedroom 32 bedroom
1 bedroom
Express unit
Bedrooms shall (107) be designated by size with the smallest bedroom being designated with the highest number3 bedroom
2 bedroom
1 bedroom
Express unit
Each bedroom shall (108) be furnished with the following:3 bedroom
Bed(s) for two persons (including mattress, box spring and metal bed frame) defined as one of the following:2 bedroom
· Master Bedroom – One standard full size bed (54” x 75”);1 bedroom
· Second Bedroom – One standard full size bed (54” x 75”);Express unit
· Third Bedroom – Two XL twin size mattresses (each 39” x 80”) placed on a free standing bunk bed frame, and not built into the manufactured housing unit
One five-drawer dresser (minimum 48” H x 33” W x 18” D)
One nightstand or equivalent
In Bedrooms 1 and 2:3 bedroom
· One of the short sides of the bed shall (109) be designated as the head of the bed, and that short side shall (110) be placed against a wall
· Of the three remaining sides, two shall (111) have a minimum of twelve inches (12”) between the bed and the nearest wall
· The final side of the bed shall (112) have open access of at least twenty-four inches (24”) from the nearest wall2 bedroom
1 bedroom
Express unit
In Bedroom 3:3 bedroom
· One of the short sides of the bed shall (113) be designated as the head of the bed and that short side shall (114) be placed against a wall
· One long side shall (115) be placed against a wall located perpendicular to the wall where the head of the bed is located
· There shall (116) be a minimum of twelve inches (12”) between the non-head, short edge of the bed and the nearest wall2 bedroom
· The final long side of the bunk bed shall (117) be open to the room1 bedroom
Express Unit
8.2 ClosetsEach bedroom shall (118) have an enclosed closet space (enclosed by a door(s)), with a minimum interior length of thirty-two inches (32”), equipped with a shelf and rod running the length of the closet and supported on both ends, and fully compliant with 24 CFR 3280 (“HUD Code”).3 bedroom
2 bedroom
1 bedroom
Express unit
8.3 Telephone and Cable Television outletsTelephone Outlet (“Jack”): Each unit shall (119) have a pre-wired telephone jack installed in each bedroom. The Telephone Jack shall (120) be wired for two lines or be a telephone jack with double outlets.3 bedroom
2 bedroom
1 bedroom
Express unit
Cable Television Outlet (“Jack”): Each unit shall (121) have a pre-wired television jack installed in each bedroom.3 bedroom
2 bedroom
1 bedroom
Express unit
The telephone and cable jack shall (122) be wired to a designated junction box for easy connection by a service provider.3 bedroom
2 bedroom
1 bedroom
Express unit
Cable and television jacks shall (123) be placed so that when the wires are plugged in it does not interfere with the usability of the unit and any safety issues such as trip hazards are avoided. At the same time, they jacks shall (124) be placed in a matter that furniture does not have to be moved to access the cable, and telephone jacks.3 bedroom
2 bedroom
1 bedroom
Express unit
9.0 Bathroom
9.1 Full Bathroom(Non-UFAS)The contractor shall (125) design and install a full bathroom in all non-UFAS units that meet the following requirements (From 9.1 to 9.1.6) and be only accessible from the common area and not from an individual bedroom.3 bedroom
2 bedroom
1 bedroom
Express unit
9.1.1 Shower and TubThe contractor shall (126) equip all standard (non-UFAS) manufactured homes with thirty inches by sixty inches (30” x 60”) shower / tub with a non-skid surface.3 bedroom
For express units: A 36” x 36” UFAS compliant shower will meet the requirement for Standard and UFAS units.2 bedroom
1 bedroom
Express unit
The shower / tub shall (127) be installed in accordance with the shower / tub manufacturer’s instructions, and be leveled so that water drains completely3 bedroom
2 bedroom
1 bedroom
Express unit
Contractor shall (128) install UFAS compliant grabs bar in shower / tub area of all manufactured homes.3 bedroom
2 bedroom
1 bedroom
Express unit
3 bedroom
The manufactured home shall (129) include an installed curtain rod2 bedroom
1 bedroom
Express unit
9.1.2 CommodeThe manufacturer shall (130) equip the bathroom with a round or elongated bowl.3 bedroom
2 bedroom
1 bedroom
Express unit
The commode shall (131) be two piece (tank and bowl are separate) and be an standard height (approx.14-15”), when measured above the floor..3 bedroom
2 bedroom
1 bedroom
Express unit
The manufacturer shall (132) install UFAS compliant grabs bar in the commode area of all manufactured homes.3 bedroom
2 bedroom
1 bedroom
Express unit
9.1.3 Bathroom SinkThe manufacturer shall (133) equip the manufactured home with a wall mounted sink3 bedroom
2 bedroom
1 bedroom
Express unit
The sink shall (134) include a properly plumbed faucet.3 bedroom
2 bedroom
1 bedroom
Express unit
9.1.4 Bathroom Medicine CabinetThe bathroom shall (135) include commercially available surface mounted medicine cabinet.3 bedroom
2 bedroom
1 bedroom
Express unit
The dimensions of the medicine cabinet shall (136) be roughly 15 ¼ inches by 30 inches.3 bedroom
2 bedroom
1 bedroom
Express unit
The medicine cabinet shall (137) be installed above the sink.3 bedroom
2 bedroom
1 bedroom
Express unit
The medicine cabinet shall (138) have a mirrored door. (a Common practice is that the top of the cabinet box (not the door trim) should be approx. 72 inches off the floor)3 bedroom
2 bedroom
1 bedroom
Express unit
9.1.5 Bathroom LightingThe bathroom lighting shall (139) be ceiling mounted, be wall-switched controlled, have dual bulb sockets, have non-breakable shades, and have two (2) compact fluorescent light (CFL) or Lighting emitting Diode (LED) bulb equivalent to sixty (60) watt bulb (120W Total), each, installed. No glass is permitted except for the bulb itself.3 bedroom
2 bedroom
1 bedroom
Express unit
In addition, there shall (140) be light specific to the medicine cabinet and sink .This lighting shall (141) be supplied either by a light fixture placed over the vanity or a light fixture placed in the ceiling above the medicine cabinet/sink.3 bedroom
2 bedroom
1 bedroom
Express unit
9.1.6 Bathroom AccessoriesOther bathroom accessories (including wall mounted toilet paper roll holder and 24 inch towel rack) shall (142) be provided.3 bedroom
2 bedroom
1 bedroom
Express unit
All faucet assemblies in the home shall (143) include secondary shutoff valves (one for each the hot and cold water supply).3 bedroom
2 bedroom
1 bedroom
Express unit
The bathroom shall (144) have an exhaust ceiling fan controlled by its own switch.3 bedroom
2 bedroom
1 bedroom
Express unit
9.2 Additional Three Quarters(3/4) BathroomThe ¾ bathroom shall (145) include all items listed in the full bathroom numbers 9.1.2 through 9.1.63 bedroom
2 bedroom
3 bedroom unit only1 bedroom
Express unit
The ¾ bathroom shall (146) not have item number 9.1.1 (Shower and Tub). Instead, the contractor shall (147) install a shower. The shower shall (148) have a minimum base of 36” x 36” (threshold). The base of the shower shall (149) be rectangular or squared in shape, and be commercially available (no custom made items).3 bedroom
Note: Threshold means the minimum acceptable.2 bedroom
1 bedroom
Express unit
10.0 Unit Hallways
10.1 Hallway WidthAll hallways shall (150) be a minimum of thirty-six inches (36”) wide.3 bedroom
2 bedroom
1 bedroom
Express unit
Designers and builders shall (151) minimize the overlap of door swings.3 bedroom
2 bedroom
1 bedroom
Express unit
11.0 Electrical
11.1 Electrical SystemElectrical systems shall (152) be in compliance with the National Electrical Code, 24 CFR 3280 and be able to supply sufficient and adequate power to the entire MHU without having breakers tripped and/or fire hazard.3 bedroom
2 bedroom
1 bedroom
Express unit
All exposed non-current carrying metals parts that may become energized shall (153) be bonded to the grounding terminal or enclosure of the distribution panel board.3 bedroom
2 bedroom
1 bedroom
Express unit
3 bedroom
All units shall (154) be ready for hook up to municipal electric service2 bedroom
1 bedroom
Express unit
The unit electrical service shall (155) consist of a 120 / 240 volts 4-wire panel board, complete with master and branch circuit breakers.3 bedroom
2 bedroom
1 bedroom
Express unit
The distribution panel board shall (156) be flush mounted inside the manufactured home in the rear bedroom on the right side of the bedroom (when facing the tongue). The panel board shall (157) be of a dead front, safety type, equipped with thermal magnetic molded case circuit breakers of the quick break type having trip indicators and common trip on all multiple breakers.3 bedroom
2 bedroom
1 bedroom
Express unit
A circuit directory shall (158) be permanently affixed to the inside of the circuit breaker access door. All circuits shall (159) be clearly and legibly identified.3 bedroom
2 bedroom
1 bedroom
Express unit
The acceptable amperage shall (160) be as defined below.3 bedroom
Amperage
· 3 bedroom: 200A
· 2 bedroom: 150A (minimum) 200 A (Maximum)
· 1 bedroom: 150A (minimum) 200 A (Maximum)
· Express Unit:100A (minimum) 200 A (Maximun)
Volts:
120/240V2 bedroom
1 bedroom
Express unit
11.2 Water Heater Specific RequirementsThe contractor shall (161) place the water heater on an dedicated circuit. This circuit shall (162) be clearly marked and the circuit shall (163) be taped in the off position. The tape shall (164) be labeled: “Water Heater: Do not turn on until water service is turned on and tank is filled”3 bedroom
2 bedroom
1 bedroom
Express unit
11.3 Interior LightingAll interior lighting fixtures shall (165) be ceiling mounted, be wall-switched controlled, have dual bulb sockets, , have non-breakable shades, and have two (2) compact fluorescent light (CFL) or Lighting emitting Diode (LED) bulb equivalent to sixty (60) watt bulb (120W Total), each, installed. No glass is permitted except for the bulb itself.3 bedroom
2 bedroom
1 bedroom
Express unit
Lighting fixtures shall (166) be provided in the living room, kitchen, all bedrooms, bathroom, hallways, and dining area. No glass is permitted.3 bedroom
2 bedroom
1 bedroom
Express unit
11.4 Service Entrance Junction BoxEach home shall (167) be equipped with a hinged, metal service entrance junction box mounted to a floor joist between the I-beam and the sidewall in such a manner that the distance from the bottom side of the junction box to the floor joist is no more than eight inches (8")3 bedroom
The junction box shall (168) be mounted at a sufficient distance from the outer edge and beneath the unit to prevent rainwater penetration (A special rain shield shall not be installed.)2 bedroom
In addition, the junction box shall (169) be located within ten feet (10’) of the right rear (when facing the tongue) of the manufactured home.1 bedroom
Express unit
The junction box shall (170) be rated NEMA 3 at a minimum and the size of the junction box shall (171) be a minimum of 12inx12inx4in.3 bedroom
2 bedroom
1 bedroom
Express unit
The junction box selection shall (172 )consider all the various angles so that the power cables can be pulled toward the box to get the lug nuts.3 bedroom
2 bedroom
1 bedroom
Express unit
The service entrance box shall (173) be connected to the circuit breaker panel using seal tight electrical conduit.3 bedroom
2 bedroom
1 bedroom
Express unit
The fittings in the junction box shall (174) be appropriate for copper that may be used to connect the junction box to the electrical service.3 bedroom
2 bedroom
1 bedroom
Express unit
The inlet shall (175) be functional, accessible and does not obstruct access to and/or from the door.3 bedroom
2 bedroom
1 bedroom
Express unit
The conductors shall (176) be continuously and appropriately color-coded or coded using colored tape wrapped around both ends of the conductors for a minimum of three inches (3"). Paint is not acceptable for coding wires.3 bedroom
2 bedroom
1 bedroom
Express unit
The contractor shall (177) not use aluminum wire to connect the service entrance box to the circuit breaker panel. The contractor shall (178) ensure that the wire used to connect the breaker panel to the service entrance box meets the minimum electrical code (NEC) and/or minimum for the forty-eight (48) contiguous United States and District of Columbia (whichever is most stringent).3 bedroom
2 bedroom
1 bedroom
Express unit
11.5 Service Junction Box For Telephone and CableEach manufactured home shall (179) be equipped with a telephone and cable inlet. The junction box shall (180) be mounted at a sufficient distance from the outer edge and beneath the unit to prevent rainwater penetration (Note: A special rain shield shall not be installed.) In addition, the junction box for telephone and cable shall (181) be located within four feet (4’) of the right rear (when facing the tongue) of the manufactured home.3 bedroom
2 bedroom
1 bedroom
Express unit
12.0 Plumbing
12.1 Plumbing SystemThe manufactured home shall(182) have at three-quarters inch (3/4”) main water supply inlet pipe and shall (183) be equipped with a metal, three-quarters inch (3/4”) master shutoff gate valve3 bedroom
2 bedroom
1 bedroom
Express unit
The manufactured home shall (184) be equipped with a frost free faucet (hose bib).3 bedroom
2 bedroom
1 bedroom
Express unit
The main water supply pipe shall (185) be comprised of three-quarters inch (3/4”) chlorinated polyvinyl chlorine (CPVC) or Cross-linked polyethylene (PEX) and extend from the water heater compartment to a point not more than six inches (6”) below the bottom board of the home.3 bedroom
Shall 186 is reserved for future use2 bedroom
1 bedroom
Express unit
Distribution lines shall (187) comply with HUD code. When using CPVC and PEX, then the piping material used may be run directly to the fixture.3 bedroom
Secondary shut off valves are still required
2 bedroom
1 bedroom
Express unit
The bathroom and washer / dryer area shall (188) be located within the same area of the home.3 bedroom
2 bedroom
1 bedroom
Express unit
The contractor shall (189) provide access panels in the walls at all points where plumbing joints exist. The access panels shall (190) match the wall and finish.3 bedroom
2 bedroom
1 bedroom
Express unit
An individual shutoff valve shall (191) be provided at each installed plumbing fixture except for the tub / shower.3 bedroom
2 bedroom
1 bedroom
Express unit
All units shall (192) be ready to connect to municipal water or local water well.3 bedroom
2 bedroom
1 bedroom
Express unit
Note: Water piping shall (193) be tested appropriately for the type of piping used. When the manufactured home is delivered to FEMA the entire water system shall (194) be dry without any water in it.3 bedroom
2 bedroom
1 bedroom
Express unit
12.2 Drainage SystemAll fixtures shall (195) be provided with an adequate drainage system, each fixture connecting to a main sewer line. The main sewer line shall (196) run below the floor and above the bottom board to the place of exit in the rear of the axles.3 bedroom
2 bedroom
1 bedroom
Express unit
The sewer line shall (197) exit the home not less than two feet (2’) but not more than three feet (3’) behind the rear axle.(It is expected that the manufacturer use a standard location among the different type of units to allow easier connectivity) The exit pipe shall (198) protrude at least six inches (6”), but not more than eight inches (8”), from the bottom board, shall (199) have a threaded end, and shall (200) be capped with a removable plastic cap and chain.3 bedroom
2 bedroom
1 bedroom
Express unit
The drainage system shall (201) be accessible without removing the wheels and/or axles during the installation and deactivation (un-installation) process.3 bedroom
2 bedroom
1 bedroom
Express unit
The drainage system shall (202) meet HUD code3 bedroom
2 bedroom
1 bedroom
Express unit
All water lines shall (203) be installed to a point above the flooring in such a manner that opening of the valves result in the complete drainage of the water lines. The drain valves shall (204) be brass.3 bedroom
2 bedroom
1 bedroom
Express unit
All units shall (205) be ready to hook up to municipal sewage or an on-site septic system.3 bedroom
2 bedroom
1 bedroom
Express unit
12.3 Water Heater / Furnace CompartmentThe manufactured home manufacturer shall (206) provide interior access to the water heater. The interior access door shall (207) be appropriately sized and located as to allow easy replacement of the water heater.3 bedroom
2 bedroom
1 bedroom
Express unit
The water heater compartment shall (208) be labeled as a “water heater compartment.” The label shall (209) include an admonition that states “No additional items should be stored in the compartment.”3 bedroom
2 bedroom
1 bedroom
Express unit
The compartment shall (210) have a light fixture and bulb to allow for maintenance. The light shall (211) be equipped with a light switch and shall (212) not have a pull string.3 bedroom
2 bedroom
1 bedroom
Express unit
Access shall (213) be provided through a door that is keyed with a single master key.3 bedroom
The master key for access to the water heater compartment shall (214) be unique and not match any other key used for interior or exterior locks providing access to the manufactured home unless specifically designated (e.g., fire sprinkler compartment). See requirement for “Water Heater Compartment Standard Key.”2 bedroom
1 bedroom
Express unit
The manufacturer shall (215) ensure that there is adequate warm air from the interior of the manufactured home into the water heater compartment so that the water heater compartment is maintained at a temperature high enough that water stored in the water heater or flowing through the compartment piping does not freeze.3 bedroom
2 bedroom
1 bedroom
Express unit
There shall (216) not be an exterior door that provides access to the water heater compartment.3 bedroom
2 bedroom
1 bedroom
Express unit
If the manufactured home is equipped with a split HVAC system, then the air handler and the furnace portion of the HVAC shall (217) be placed in the water heater / furnace compartment.3 bedroom
2 bedroom
1 bedroom
Express unit
12.4 Water HeaterA 40-gallon electric dual element quick recovery water heater shall (218) be installed. The water heater shall (219) be complete with a pressure relief valve, corrosion resistant drain pan, and a metal tank drain valve.3 bedroom
2 bedroom
1 bedroom
Express unit
The valves and drain pan shall (220) be separately piped four inches (4”) to six inches (6”) below the bottom board of the home and shall (221) be at least five inches (5”) away from the water inlet pipe. The corrosion resistant water drip collection pan, relief valve, and corrosion resistant drain pan shall (222) be separately piped to the exterior.3 bedroom
2 bedroom
1 bedroom
Express unit
Piping shall (223) be installed at the factory.3 bedroom
2 bedroom
1 bedroom
Express unit
Relief valve shall (224) be placed to exterior but pointed down with downward directed outlet to ground.3 bedroom
2 bedroom
1 bedroom
Express unit
12.5 Plumbing Controls and Faucet AssembliesAll faucet assemblies in the home shall (225) include secondary shutoff valves (one for each the hot and cold water supply).The secondary shutoff shall (226) be located in close proximity to the faucet assembly (i.e., under the sink).). A secondary shutoff valve is not required for the tub/shower assembly.3 bedroom
2 bedroom
1 bedroom
Express unit
13.0 Attic
13.0 Radiant BarrierThe contractor shall (227) install a reflective insulation system in the attic with either a radiant barrier or reflective insulation product as a component. A radiant barrier is made of highly reflective material and may be reinforced with a middle fabric layer making it puncture and tear resistant.3 bedroom
2 bedroom
1 bedroom
Express unit
Radiant barrier insulation shall (228) be energy star compliant: ninety-five to ninety-seven percent (95-97%) of the radiant heat will reflect back to its source when installed properly. Radiant reflective paint [Interior Radiation Control Coatings (IRCC)] is not acceptable.3 bedroom
2 bedroom
1 bedroom
Express unit
14.0 Structural System
14.1 Transportation System and Main FrameThe main frame of the unit shall (229) be a twelve inch (12”) steel I-beam3 bedroom
2 bedroom
1 bedroom
Express unit
The contractor shall (230) provide and install two (2) additional I-beams of the same material and composition as the main frame shall (231) extend a minimum of eighteen inches (18”) on each side of the axle group, with each additional I-beam measuring fourteen feet (14’0”) minimum in length.3 bedroom
2 bedroom
1 bedroom
Express unit
The additional I-beams shall (232) be installed in accordance with DAPIA approved designs and centered over the axle area in such a manner that the main frame I-Beam is doubled forward and aft through the axle area.3 bedroom
2 bedroom
1 bedroom
Express unit
The frame shall (233) be secured to the floor joist system and the frame alignment shall (234) be maintained by installing appropriate steel fasteners and lag bolts at every floor joist3 bedroom
2 bedroom
1 bedroom
Express unit
The contractor shall (235) provide documentation that the manufactured home complies with 24 CFR 3280.903.3 bedroom
2 bedroom
1 bedroom
Express unit
14.2 OutriggersThe manufacturer shall (236) provide and install industry standard tapered outriggers (minimum twelve gauge), preformed C- or Z-type, and twelve (12) gauge outriggers having a base of nine inches (9”) nominal3 bedroom
2 bedroom
1 bedroom
Express unit
Outriggers shall (237) be installed the entire length of the home at forty-eight inch (48”) on center (o.c.). The outriggers shall (238) be mounted to the main frame I-Beam by DAPIA approved on both sides. The outriggers shall (239) terminate flush with the perimeter floor joist and be secured at this point with a lag bolt.3 bedroom
2 bedroom
1 bedroom
Express unit
Additional outriggers shall (240) be provided and installed at each location where a shackle (spring hanger) is mounted to the main frame I-Beam.3 bedroom
2 bedroom
1 bedroom
Express unit
Tolerances shall (241) be in compliance with the DAPIA approved designs and specifications.3 bedroom
2 bedroom
1 bedroom
Express unit
14.3 Front/Rear Cross-MembersThe contractor shall (242) provide and install front and rear cross-members (aprons). Each cross-member shall (243) be the width of the unit and constructed of a minimum twelve inch (12”) I-Beam. Each cross-member shall (244) be fastened to the front and rear perimeter floor joists, respectively, with a minimum of six (6) lag bolts evenly spaced from corner to corner along the length of the cross-member.3 bedroom
2 bedroom
1 bedroom
Express unit
14.4 Cross- MembersThe contractor shall (245) provide and install cross-members. The cross-members shall (246) be installed the entire length of the home, located between the two main frame I-Beams, be forty-eight inches (48”) on center, and in accordance with the DAPIA approved designs and specifications.3 bedroom
2 bedroom
1 bedroom
Express unit
14.5 ConnectionsAll lag bolts shall (247) be at least five-sixteenths of an inch by three inches (5/16” x 3”; acceptable alternative is 9 mm x 76 mm) and be fully threaded. At least one lag bolt shall (248) be used to connect each outrigger to the perimeter joist and at least one lag bolt shall (249) be used to connect the 1” x 1 1/2” x 12 gauge clip that is welded to each main I-beam and connected to each floor joist at sixteen inches (16”) on center.3 bedroom
2 bedroom
1 bedroom
Express unit
14.6 CoatingsAll exposed surfaces of the entire frame shall (250) be completely coated after welding. This coating shall (251) be waterproof. The serial number shall (252) be painted with rust resistant contrasting color paint, 2 inches (2”) tall.3 bedroom
2 bedroom
1 bedroom
Express unit
14.7 Floor JoistsThe floor joists shall (253) be two inches by eight inches (2” x 8”) nominal and run transverse to the length of the unit. Floor joists shall (254) be spaced sixteen inches (16”) on center and splicing of the floor joists is not acceptable. A two inches by eight inches (2” x 8”) nominal rim member shall (255) be installed to enclose the floor perimeter. The floor joists shall (256) be SPF # 2 or better or equivalent.3 bedroom
2 bedroom
Note: Alternatives methods used shall be approved by the DAPIA prior submission. However. Southern Yellow Pine (SYP) will not be accepted1 bedroom
Express unit
14.8 Floor DeckingThe floor decking shall (257) be composed of 3/4” (23/32”) minimum thickness material that meets the requirements set forth in 24 CFR 3280.308; panels with joists spacing index of 24 (long edges of the panel shall (258) be tongue and groove, and with sixteen inches (16”) on center floor joists. The decking should be placed perpendicular to the joist length.3 bedroom
2 bedroom
1 bedroom
Express unit
Shall (259) is reserved for future use.3 bedroom
2 bedroom
1 bedroom
Express unit
Floor shall (260) be designed and constructed to resist floor loads to which it may be exposed.3 bedroom
2 bedroom
1 bedroom
Express unit
14.9 Floor and CeilingFloor and ceiling cavities shall (261) be insulated with flame retardant insulation and shall (262) have a minimum R rating of nineteen(R-19) in accordance with 24 CFR 3280.506.3 bedroom
2 bedroom
1 bedroom
Express unit
Condensation control (vapor barriers) shall (263) be installed in accordance with section 24 CFR 3280.504.3 bedroom
2 bedroom
1 bedroom
Express unit
14.10 Ceiling HeightThe interior height of the ceiling shall (264) be eight feet (8’).3 bedroom
2 bedroom
1 bedroom
Express unit
The ceiling shall (265) have a nominal height between seven feet eleven inches (7’ 11”) and eight feet one inch (8’ 1”).3 bedroom
2 bedroom
1 bedroom
Express unit
14.11 Interior WallsA minimum one inch by three inch (1” x 3”) bottom plate shall (266) be installed at all locations of interior walls3 bedroom
2 bedroom
1 bedroom
Express unit
All interior walls studs shall (267) be framed (studded) with minimum two inch by three inch (2” x 3”) nominal lumber spaced on 16” centers.3 bedroom
2 bedroom
1 bedroom
Express unit
Interior walls shall (268) be secured to a minimum two inch by three inch (2” x 3”) top plate3 bedroom
2 bedroom
1 bedroom
Express unit
All openings for interior doors and alcoves shall (269) be double framed with the same materials as the interior door studs and shall (270) have headers/framing member from the top of the door to the ceiling.3 bedroom
2 bedroom
1 bedroom
Express unit
14.12 Roof TrussesRoof trusses shall (271) be installed the entire length of the home with a maximum of sixteen inch (16”) on centers (o.c.) and each shall (272) align with an exterior wall stud.3 bedroom
2 bedroom
1 bedroom
Express unit
The exterior walls shall (273) be connected to the roof trusses with a hurricane strap (also known as hurricane clip).3 bedroom
2 bedroom
1 bedroom
Express unit
The roof trusses shall (274) not be cut for the passage of any electrical, plumbing, and/or mechanical system.3 bedroom
2 bedroom
1 bedroom
Express unit
Exterior roof coverings shall (275) be secured to minimum three-eighths inch (3/8”) structural rating sheathing. See Part 3280.305 (HUD Standard, Table of Design Wind Pressures, Footnote 7).3 bedroom
2 bedroom
1 bedroom
Express unit
14.13 Exterior WallsThe exterior wall framing (studs) shall (276) be two inches by six inches (2” x 6”) nominal installed at a maximum spacing no greater than sixteen inches on center(16” o.c.), and secured to the top and bottom plate3 bedroom
2 bedroom
1 bedroom
Express unit
The strapping of the wall studs to roof trusses and perimeter joists shall (277) be twenty-six (26) gauge minimum steel straps or brackets at sixteen inches on center(16” o.c.), to conform to the requirements of Wind Zone III conforming to 24 CFR 3280.305 (e)(2).3 bedroom
2 bedroom
1 bedroom
Express unit
The exterior walls shall (278) be connected to the roof trusses with a hurricane strap (also known as hurricane clip).3 bedroom
2 bedroom
1 bedroom
Express unit
The exterior walls shall (279) be insulated with flame retardant insulation having a minimum R rating of nineteen (19).3 bedroom
2 bedroom
1 bedroom
Express unit
Condensation control (vapor barriers) shall (280) be installed in accordance with Part 3280 (HUD Standard) 24 CFR 3280.504.3 bedroom
2 bedroom
1 bedroom
Express unit
The insulation shall (281) be “batt” wall insulation for this application.3 bedroom
2 bedroom
1 bedroom
Express unit
Anchoring strap shall (282) be secured to each full length wall stud on each side of all double-framed door and window openings. (Straps are not required on jack studs.)3 bedroom
2 bedroom
1 bedroom
Express unit
All exterior openings such as windows, doors, drain pipes, etc., shall (283) be caulked to prevent air and moisture penetration.3 bedroom
2 bedroom
1 bedroom
Express unit
All exterior penetrations (e.g. doors, windows, vents, exterior lighting, and power outlets) shall (284) be equipped with ice and water shields.3 bedroom
2 bedroom
1 bedroom
Express unit

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .