Attachment_5_Manufactured_Home_Acceptance_Inspection_List.xlsx

XLSX spreadsheet 53 KB Posted

Attached to
Manufactured Housing Units Federal contract opportunity
Solicitation number
HSFE70-14-R-0005
Issued by
Federal Emergency Management Agency Logistics Section

About this file

Attachment 5 - MHU Home Acceptance Inspection Checklist

View the file

Other files for this federal contract opportunity

Other files attached to Manufactured Housing Units, newest first.
File Type Posted
Attachment_3_RBPR_Matrix_2nd_Half_.xlsx XLSX spreadsheet
Attachment_2_F_R_B_Performance_Requirements__versionBB_23July2014.pdf PDF
HSFE70-14-R-0005_A00003.pdf PDF
MHU_Solictation_QA_Comment_Matrix_18_Jul_14.xlsx XLSX spreadsheet
Attachment_16_Section_E_MHU_Quality_Assurance_Plan_18Jul2014.pdf PDF
HSFE70-14-R-0005_Solicitation_A00002_.pdf PDF
Attachment_2_F_R_B_Performance_Requirements__versionBB_18July2014_1600_.pdf PDF
Attachment_3_FEMA_Rugged_Based_Performance_Requirements_Matrix_18July2014_1600.docx DOCX document
HSFE70-14-R-0005_A00002.pdf PDF
Responses_to_Draft_RFP_Comments_HSFE70-14-R-0005.pdf PDF
HSFE70-14-R-0005_A00001.pdf PDF
Attachment_20_Reference_Table.pdf PDF
Attachment_2_F_R_B_Performance_Requirements__versionBB.pdf PDF
Attachment_16_Section_E_MHU_Quality_Assurance_Plan.pdf PDF
Attachment_7_Delivery_Schedule_Template.xlsx XLSX spreadsheet
Attachment_17_MHU_sizing_table_for_Section_L.pdf PDF
Attachment_4_MHU_First_Article_Testing_Inspection_Checklist.xlsx XLSX spreadsheet
HSFE70-14-R-0005_Solicitation.pdf PDF
Attachment_6_MFG_shipment_sheet.xlsx XLSX spreadsheet
Attachment_8_Unit_Production_Report.xlsx XLSX spreadsheet
Attachment_12_Warranty_Repairs_In_The_Field_List.xlsx XLSX spreadsheet
Attachment_15_Comment_Matrix_.xlsx XLSX spreadsheet
Attachment_11_Design_Details_for_Accessible_Disaster_Relief_Housing_Guide.pdf PDF
Attachment_9_Invoice-Sample_Summary.pdf PDF
Attachment_19_MHU_Idenfication_Number_Summary.pdf PDF
Attachment_10_Production_Facility_Inspection_Report.pdf PDF
Attachment_13_Acronyms_and_Definitions.pdf PDF
Attachment_18_Minimum_Essential_Requirements.pdf PDF
Attachment_1_-_Pricing.xlsx XLSX spreadsheet
Attachment_3_FEMA_Rugged_Base_Performance_Requirements_Matrix.pdf PDF
Attachment_14_MHU_Past_Perofrmance_Questionnaire.pdf PDF
Attachment_3_HSFE70-14-R-0005_Requirement_Matrix.pdf PDF
Attachment_9_Invoice-Sample_Summary.docx DOCX document
Attachment_8Unit_Production_Report.xlsx XLSX spreadsheet
Attachment_2_F_R_B_Performance_Requirements__19dec2013_1517.docx DOCX document
Attachment_10_Production_Facility_Inspection_report.docx DOCX document
Section_B_CLIN_Table_and_Small_Business_Scenarios_1c_and_1d_01312014_1108_hrs.xlsx XLSX spreadsheet
HSFE70-14-R-0005_draft_Sol-2-6-14.pdf PDF
Attachment_11_Design_Details_for_Accessible_Disaster_Relief_Housing_Guid....pdf PDF
Attachment_7_Delivery_Schedule_Template.xlsx XLSX spreadsheet
Attachment_6_MFG_shipment_sheet.xlsx XLSX spreadsheet
Attachment_13_Acronyms_and_Definitions_17dec2013.docx DOCX document
Attachment_12_Chargeback_List_06Dec2013_1510_hrs.xlsx XLSX spreadsheet
MHU_PPQ_Form_12-18.docx DOCX document
Attachment_4_MHU_First_Article_Testing_Inspection_Checklist.xlsx XLSX spreadsheet
Attachment_15_Comment_Matrix_.xlsx XLSX spreadsheet
Attachment_5_Manufactured_Home_Acceptance_Inspection_List_19dec2013.xlsx XLSX spreadsheet
Section_B_CLIN_Table_and_Non_Small_Business_Scenarios_1a_and_1b__06022014.xlsx XLSX spreadsheet
Synopsis_For_MHU_Long_Term_1-8-14.pdf PDF
Show all 49

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

FEDERAL EMERGENCY MANAGEMENT AGENCY

MANUFACTURED HOME INSPECTION CHECKLIST (MHU)

1. FEMA Unit Identification Number 2. Date of Inspection

3. Serial Number4.Factory Location of the Inspection5. US Government Barcode
(added after inspection)6. Weather Conditions(External Temperature, humidity )

7. Printed Name of Exterior Inspector 8. Signature of Exterior Inspector 9. Date

10. Printed Name of Interior Inspector 11. Signature of Interior Inspector 12. Date

13.Recommendation to Accept / Deny14. Final Acceptance (Signature and Print Name)
*ACCEPT unit as is
*DENY unit as is
15. Unit Details16. Unit Type17. Instructions
1 Bedroom*Manufacturer• Indicate with an X in the Pass or Fail column if the unit passes or fails the requirement.

• When Requirements includes measurements, indicate measurement in the Notes column.

• Supplement checklist with additional information in the Notes column.

• Attach to this checklist a copy of the unit floor plan. Circle or mark areas that do not meet Requirements, and include the reference number.

• If Exterior and Interior Inspector is same person, then write "Same" in 10-12.

• If necessary, reattach all four pages before submitting checklist.

2 Bedroom*
3 Bedroom*
Northern*Year
Southern*
UFAS*
NON UFAS*
EXTERIOR
Exterior ConditionPassUFailNotes
18.Reserved for future use
19.Axles include grease fitting that are secured from environmental conditions when not being accessed during maintenance
20.If no shrink wrap, not covered in or has residue of materials including oil, tar, or grease
21.Manufacturer removed exterior shipping materials, like plastic, wrap, nails, etc.
22.Reserved for future use
23.Window screens secured with removable, reusable, non-corrosive shipping clips. No Tape or other temporary securing methods
24.Tires are new, size 8.00 x 14.5, Series "E," or better and not defective
25.Tire rims clamps, bolts, nuts, and related hardware are new
26.Adequate number of axles as per contract (to be filled in after award)
27.Transportation system components installed with locking nuts or lock washers
Exterior DocumentationPassUFailNotes
28.Documentation that the weight of the unit does not exceed the allowable weight for the number of axles provided
29.HUD label placed on unit exterior
30.Manufactured Home Serial Number stenciled in white or contrasting color, 2” tall on the tongue. Must match stamped serial number and serial number on HUD data plate.
31.Unit number placard on exterior left front corner between 3" from the bottom of adjacent roof eve and no more than 3" from left edge of unit
32.Manufactured Home ID is black, 3" high, and 2' from bottom of roof line
DrawbarPassUFailNotes
33.Painted Blue if Northern unit , Red if Southern unit, Green if CONUS Unit
34Drawbar welded (not bolted), made of 12" I-beam, and centered for towing
35All welds are continuous
36All welds are primed and painted with rust preventative paint
ExteriorPassUFailNotes
35.Reserved for future use
36.All exterior penetrations are properly sealed and caulked
37.Siding is light grey, manufacturer's full vinyl siding or similar material
38.Roof shingles are white or light colored composition shingle
39.Reserved for future use
40.Bottom board is secured, moisture resistant under whole unit, prevents rodents from entering, and allows for cross tie anchoring buckles
41.UL-approved weatherproof exterior light fixtures exist at each exterior door, are metal with non-breakable globe, have CFL bulb equal to 60 watt incandescent(does the light will be installed at the time of delivery?), and have interior wall switch near door the light serves
42.Exterior heat tape receptacle is a single outlet with weatherproof case, is within two feet of water pipe inlet, and is not a GFCI
43.Weatherproof outdoor duplex receptacle flush mounted on exterior wall about 5' from water inlet, and 6" up from floor level
44.Northern units have one additional weatherproof(Non GFCI) outdoor duplex receptacle within 2 feet of water pipe inlet
45.Wooden board or other material installed to deflect or prevent damage to “Bottom Board” or other items above the tires. Material will not rot or rust
46HVAC cover exists (Verify that the cover is not broken)
47Metal service entrance junction box mounted to floor joist between I-beam and sidewall, 8" maximum between box and floor joist. Box within 10' of right rear of unit without blocking exit
48Verify that the Junction box is rated NEMA 3 or better
49Verify that the Junction Box Size is 12"X 12"X 4"(minimum)
50Verify that the Service Entrance Junction Box connected to the circuit breaker panel
51Exterior doors are 36” x 76,” hinged toward rear of unit, and do not block/touch windows when open
52Exterior doors have 1 peephole 5' 3" from finished floor AND 1 peephole 3' 7" from finished floor
53Roof penetrations capped with a galvanized metal cap. No rubber grommets
Mark Location of Exterior Damage

54 Left Side

55 Right Side

56 Front 57 Back

58 Roof

59 Undercarriage

INTERIOR
Living RoomPassUFailNotes
601 futon(Metal or wood frame only with) with a mattress and a cover , 1 arm chair(constructed of non-permeable material such as wood, without fabric covering), 1 coffee table, and 1 end table exist and are in new condition
61All furniture assembled with all packing material removed from the manufactured home.
62Furniture is not Damaged
63Furniture free from sharp, abrasive surfaces and edges.
64Wired Telephone Outlet jack installed(Have the contractor Open and check for connection)
65Wired Cable Television Outlet jack installed (Have the contractor Open and check for connection)
KitchenPassUFailNotes
663 sets of keys with serial / VIN number and space for barcode, placed in sink. Verify that the keys are pertinent for each unit
67The unit is equipped 18 cubic foot frost-free refrigerator with freezer,
68The frost-free refrigerator secured to the floor and wall stud(minimum)
69The frost-free refrigerator is not connected to the receptacle
70Minimum Linear inch length for the upper (wall) cabinet is 36 in
71The upper and lower cabinets have fixed shelving
72Cabinets are constructed with a finish compatible with the interior decor
73Installed Countertops are laminate countertops and have a post formed backsplash
74The counter top shall be formed from a single piece of laminate that's shaped into a backsplash at the rear and a rounded edge in front
75The minimum size of the backsplash height is 4 inches
76Minimum 36" of counter space, not including dining table
77Refrigerator is on its own circuit (check circuit breaker box for separate labeled refrigerator circuit breaker)
78Refrigerator can be opened from inside (there are no locks on the refrigerator door)
79When the refrigerator is open , it does not impede access when approaching from the Kitchen Area
80Stand alone 1.2 cubic foot microwave with child lock OR microwave/hood/fan/light combination exists
8130" self-cleaning 4 burner electric range with indicator light and thermostat-controlled oven
82Lighted, power-vented hood range hood (one-piece construction OR microwave/hood/fan/light combination)
83There is not a separate sidewall vent for range/oven
84Range is plugged in to the Range electric plug and secured to floor with a minimum 2 gusset angle brackets
85Cabinetry is wall-mounted in the kitchen, verify that the cabinets are not loose
86Sink is stainless steel , self-rimming double-bowl, minimum of 33"L x 22 "H basin depth : 8" with spray nozzle of 24" extension and metal strainer basket
87Reserved for Future Use
88All faucet assemblies are dual shutoff valve(Each line have shutoff valves, hot water and cold water)
89Minimum of four(4) receptacles are in the kitchen area above the counter
90Receptacle for range is flush mounted in the wall behind range
Dining AreaPassUFailNotes
91Dinette table is at least 3' x 5' (1 and 2 bedroom units), 4 dining chairs for adults exist
923 bedroom units: 6 dining chairs for adults exist. Table at least 3' x 6' 6".
93Furniture for the dining area is be composed of wood
94Furnishing designated for the dining area does not have any porous fabric material.
95Furniture is not Damaged
96All dining room area furniture is assembled with all packing material removed from the MH
BedroomsPassUFailNotes
98If 2 or 3 bedrooms, one bedroom(As described in Rugged Based Requirements Version BA) is larger
99Each bedroom has an enclosed closet (door) with minimum interior length of 32"
100Closets have shelf and rod running length of closet with support at both ends
101Each bedroom has a 5-drawer dresser minimum 48"H x 33"W x 18" D
102Each bedroom has at least one night stand or equivalent
103Reserved for Future Use
104Each bedroom has at least one mattress, box spring, and metal bed frame
105Master Bedroom(Bedroom1) has a standard 54" x 75" bed
106Bedrooms 2 has a standard 54" x 75" bed
107Bedroom 3 has two 39" x 80" mattresses placed on a free standing bunk bed
108Reserved for Future Use
109Each bedroom has a receptacle on each wall
110Reserved for Future Use
111Smoke alarms with strobe component installed in each bedroom(moved to smoke alarms)
112Wired Telephone Outlet jack installed
113Wired Cable Television Outlet jack installed
BathroomPassUFailNotes
114Standard 30" x 60" shower/tub combination exists
115Bathroom have UFAS compliant grabs bar in shower/tub area
116Curtain rod, wall mounted toilet paper roll holder, and 24 inch towel rack are installed
117MH have a round or elongated bowl
118Toiler is two piece(Tank and bowl are separate)
119MH have is bowl is standard height(approx.14-15”)
120The Manufactured home have a surface mounted medicine cabinet which dimensions are 15 ¼ inches by 30 inches(roughly)
121The medicine cabinet has a mirrored door.
122The medicine cabinet is installed above the sink. (A general rule of thumb is that the top of the cabinet box (not the door trim) should be 72 inches off the floor)
123All faucet assemblies include secondary dual shutoff valve for hot/cold water
124The MH is equipped with a wall mounted sink that include a properly plumbed faucet
125MH is equipped with a Lighted exhaust ceiling fan
3/4 Bathroom (3 bedroom units only)PassUFailNotes
126Shower has a minimum base of 36” x 36” (threshold)
127The base of the shower is rectangular or squared in shape and be commercially available (no custom made items)
128MH have a round or elongated bowl
129Toiler is two piece(Tank and bowl are separate)
130MH have is bowl is standard height(approx.14-15”)
131Wall mounted toilet paper roll holder and 24 inch towel rack are installed
132All faucet assemblies include secondary dual shutoff valve for hot/cold water
133Reserved for Future Use
134Reserved for Future Use
135Reserved for Future Use
Water Heater Closet and Water HeaterPassFailNotes
136Electric, 40 gallon (dual element) quick recovery water heater exists and it is installed on individual circuit and has pressure relief valve, corrosion resistant drain pan and metal tank drain valve.
137Water heater compartment is labeled and states “No additional items shall be stored in the compartment.”
138Water heater is in its own circuit.
139Water heater circuit is clearly marked and the circuit shall be taped in the off position and the tape shall be labeled: “Water Heater: Do not turn on until water service is turned on
140Interior access to water heater uses "SCHLAGE” brand key/dead bolt lock unique to closet (check to ensure that the key works)
AppliancesPassFailNotes
141Appliances are energy star high efficiency and/or energy star qualified (Check for labels)
142Refrigerator is disconnected
143Range is connected to the plug
Laundry AreaPassUFailNotes
144Laundry Area includes plumbing, electrical connections and dryer vent
145The Dryer vent exhaust to the exterior so that when connecting the dryer duct, the dryer exhaust to the outside.
146Dryer exhaust system does not terminate under the home.
147Washer and Dryer hookup does not require any modification to install a washer and/or dryer.
148The washer / dryer area should be able to accommodate a standard size side by side washer/dryer (i.e., 27" wide, 36" high and comes out from the wall 29 inches)
Plumbing, Electrical, and ElectronicsPassUFailNotes
Electrical, and Electronics(General)PassUFail
149Electric service of either 200 amp for 3 bedroom ,150 amp for 2 bedroom and 100 amp for express unit circuit breaker panel installed (minimum)
150All electrical circuits are clearly and legibly identified
151Switches are located 44" to 48" above finished floor
152Electrical outlets 18" above finished floor and not self-contained devices
153Receptacles near wet areas are protected with ground fault interrupter
HVACPassUFail
154Whole house electric HVAC system exists without individual/window HVAC appliances in individual rooms,

FEMA HVAC systems is one of the following

a) Central Air Conditioner/Split System, b) Mini Split / Ductless Split

c) Packaged Unit

155Digital thermostat with automatic settings exist and thermostat allows for temperature adjustment
156Digital thermostat is located 44" to 48" above finished floor
157HVAC does not require additional installation
158If no shrink wrap, weather proof covering on the external mounted portion of the HVAC("HVAC Cover")
159Heat duct openings covered with 4" x 10" metal, adjustable louvered register
Lighting RequirementPassUFailNotes
160Lighting fixture in living/dining room, kitchen, each bedroom, bathroom, hall
161All interior lighting fixtures are ceiling mounted
162All interior lighting fixtures are wall-switch controlled with dual sockets
163There are no hanging lights
164All fixtures are equipped with non-breakable shades (no glass permitted)
165All fixtures have CFL or LED bulb equivalent to 60 watt bulb installed
MoldingPassUFailNotes
166All trim molding is color matched/coordinated to the interior paneling
167All seals, joints, door/window frames, corners (visible or not) are finished
168Exposed panel edges covered with permanently attached non-plastic edging
Internal ConditionPassUFailNotes
169MHU must be free from defective materials or workmanship
170Reserved for Future Use
171Reserved for Future Use
172Reserved for Future Use
173Reserved for Future Use
174Furniture packed in a manner so that it is not damaged during multiple transportations or in the unpacking process and is in the room it will be used
Internal DocumentationPassUFailNotes
175Unit Contact Placard on interior side of exterior doors, adjacent to upper peephole, top of sign shall not be higher than 66” above finished floor
176Unit Contact Placard has white background, black 1” font stating “FEMA Owned & Maintained Unit Contact FEMA at 800-621-FEMA,” space to write barcode provided
177Unit Data Placard in interior side of water heater closet door, 3 inches from latch side, top of placard 5’ from bottom of the door, blue font 1/4" high
178HUD data plate exists on/near main electrical panel, in kitchen cabinet, or in bedroom closet
Safety DevicesPassUFailNotes
179Smoke alarms are audio/visual with a strobe component and have battery backup
180Smoke alarms are interconnected and utilize the electrical system of the home as the primary power source (with battery back-up included). (Have the vendor to cut off the electrical power (using the appropriate breaker) to verify if the battery backup works)
181Smoke alarms have push-button testing and temporary silencing devices
182Smoke alarms with strobe component installed in each bedroomSmoke alarms with strobe component installed in each bedroom(moved to smoke alarms)
183Smoke alarms exists in living room/dining/kitchen area
184NOAA/FCC Weather Radios are equipped with strobe component that works with electrical power and battery backup
185Reserved for Future Use
1865 pound A-B-C fire extinguisher exists with mounting bracket secured to wall stud in living room/kitchen area
Floor CoveringPassUFailNotes
187Interior floors are continuous roll, non-foam resilient, non-skid (no carpet)
188A rug or door mat about 30" x 15" is placed at each entrance
189Heat duct openings covered with 4" x 10" metal, adjustable louvered register
Windows (Egress window)PassUFailNotes
190Windows are double-paned, at least 30" x 54," w/ window screens & mini-blinds
191No shutters, and labeled as and affixed with operating instructions for egress
UFAS
Living RoomPassUFailNotes
192Electrical receptacle for TTY next to the living room phone jackX
KitchenPassUFailNotes
193Appliances are not obstructed, have 30" x 48" clear floor space for forward/parallel approachX
194Sink is a maximum of 6.5" deep, 34" high, with knee clearanceX
195Sinks and cabinets are wall-supported, finished floors/walls exist under base cabinetsX
196Self-cleaning oven with insulation on all sidesX
197Hot water and drain pipes insulated or protected and no sharp/abrasive surfaces under sink
198Reserved for Future UseX
BedroomsPassUFailNotes
199Reserved for Future UseX
BathroomPassUFailNotes
20030" x 60" roll in shower with non-skid surfaceX
201Folding seat in shower is 17" to 19" in height, secured to short wall, and perpendicular to control wallX
202Grab bars installed in shower on back wall and wall opposite seat between 33" and 36" above the finished floor (but not extended over seats)X
203Counter surface maximum 34" high, bottom of mirror maximum 40" highX
204Handicap toilet installed with top of seat 17" to 19" from the floorX
205Water closet between 15" and 19" from the top of the toilet seatX
206Clear floor space of 30" x 60"X
207Flush controls mounted on the wide side of toilet, maximum 44" above floorX
208Rubber stopper or a means to prevent water from running out of the shower exists
209Hot water/drain pipes under lavatories are insulated/coveredX
Washer / DryerPassUFailNotes
210Reserved for Future UseX
Visual Scan of Doorways, Hallways, Interior Receptacles and BathroomPassUFailNotes
211Switches/receptacles above obstructions/countertops are 44" above finish floorX
212Oven self-cleaning or adjacent to adjustable height counter with knee spaceX
213Controls do not require reaching across burnersX
214Switch to operate power vent operable with one handX
215Doors - Open 90°; minimum opening 32"; raised thresholds/floor level changes beveled (maximum slope 1:2 and height 1/2"); handles extend 2" from door surface and have 1.5" clearance on either sideX
216All rooms include a turning radius of 60" or a T-shaped spaceX
217Knee clearance at tables, counters, and work surfaces is at least 27" high, 30" wide, and 19" deepX
218Refrigerator either vertical side-by-side type or over-under type with at least 1/2 freezer space under 54" above floorX
219Work surfaces are between 28" and 34" from the groundX
220Reserved for Future Use
221Reserved for Future UseX
222Hallways are a minimum of 36” wideX
223Reserved for Future UseX
Shrink Wrapped unitsPassUFailNotes
224Either solar or wind vent fans exist. Fans placed in front of two windows on opposite sides (long side) of the unit (Shrink Wrapped Units Only)