The file's text, extracted by GovTribe without its formatting.
Attachment C Specifications for the Recycle/Disposal Of Nylon String Reinforced Blue Roof Plastic Sheeting
HSFE70-14-I-0013
January 15, 2014
TABLE 1
| ITEM |
| REQUIREMENTS |
| REFERENCE/TEST |
| Color: |
| Blue |
| Pantone 3005c to 2945c |
| Tensile Grab Strength |
| 50/50 lbf |
| ASTM D7004 |
| Elongation at Break |
| 550% |
| ASTM D7004 |
| Trapezoid Tear |
| 20/20 lbf |
| ASTM D4533 |
| Mullen Burst |
| 90 psi |
| ASTM D751 |
| Dimension Stability |
| <5% |
| ASTM D1204 |
| Oxidative Induction Time |
| 20 min |
| ASTM D3895 |
| Flame Retardant |
| Class A |
| ASTM E84-97a |
| Seam Strength (Shear Strength) |
| 80% of TD Tensile |
| ASTM D751 |
| (Peel Strength) |
| 10 ppi |
| ASTM D751 |
| UV Resistance |
| 80% after 200 hr |
| ASTM G23 |
| Thickness |
| 10 mil |
| ASTM D-5199-95 |
| Multi-Axial % Deflection |
| 20% |
| ASTM D5617 |
| Reinforcement |
| Polyester |
| 1000 Denier |