PROJECT
LOCATION
N
LAKE
MERRITT
G R A N D
A V
EOAK
LAN
D A
VE
39TH STMACARTHUR BLVD
P E R
AL
TA
S T
A D E
LI
N E
S T
M A R K E T S T
B R O A D W A Y
PI
ED
M
ON
T
AV
E
TH
A
VE
FO
O
TH
ILL B
LVD
E.14TH
ST
7TH ST
14TH ST
S A N
P A B
LO
A V E
PAR
K
BL
VD
O
AK
S T
E.12TH ST
T E
LE
G R A P H
A V E
H A R R
IS
O N
S T
LAK
E S
ID
E
D R
12TH ST
C L A Y S T.
T H
S T
R E
E T
B R O A D W A Y
T H
S T
R E
E T
ELEVATORS
EXIT STAIRS
EXIT STAIRS
ACCESSIBLE RESTROOMS
ACCESSIBLE DRINKING
FOUNTAIN
ACCESSIBLE PATH OF TRAVEL
AREAS OF NO WORK
ETE
C-27362
RENEWAL
O
S T
T A
CI
L
E
T
AI
N
C
RDATE
F LA IC
FO
ES
N I
CHD AR
E R
IB
. HUS A
A M
R
C S
01-31-2019
ISSUE DATE: BY:
1/16" = 1'-0"GRAPHIC SCALES:
5'0 50' 0 5'
1/8" = 1'-0" 1/4" = 1'-0"
25' 0 1' 12'
1/2" = 1'-0"
0 1' 6' 0
1" = 1'-0"3/4" = 1'-0"
4' 0 1'
1 1/2" = 1'-0"
03' 2' 0
A REDUCED PRINT SCALE ACCORDINGLY
IF THIS SHEET IS NOT 30"x42" , IT IS
3" = 1'-0"
1'
Client Project Number:
Sheet
Drawn By:
Checked By:
Revit Version:
Facility
Project
Sheet Title
Scale:
Sheet
HY Architects Project number:
Revisions#
This document is the property of the Owner and is not to be used without his written permission
Architect/Engineer Of Record:_________________________________________________
SL7/28/17
100% CONSTRUCTION
DOCUMENTS
of
Issue Date:
/2
/2
:0
:2
P M
C
R e v it L o c a ls \G
S A th
F lo o r
C o n fe re n c e
R o o m
R
V T s d o s ic k .r v t
As indicated
FEMA REGION IX
12TH FLOOR CONFERENCE ROOM
1111 BROADWAY OAKLAND, CA 94607
SD
SL
12TH FLOOR CONFERENCE
ROOM
TITLE SHEET
A0.01
1111 BROADWAY OAKLAND, CA 94607
Client Proj. #
Project Number
7/28/17
ALL WORK PERFORMED UNDER THIS CONTRACT IS TO CONFORM TO THE FOLLOWING
CODES AND REGULATIONS:
2016 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE,
PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR)
2016 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24, CCR
BASED ON THE 2015 INTERNATIONAL BUILDING CODE (IBC)
2016 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24, CCR
BASED ON THE 2014 NATIONAL ELECTRICAL CODE (NEC)
2016 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24, CCR
BASED ON THE 2015 UNIFORM MECHANICAL CODE (UMC)
2016 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24, CCR
BASED ON THE 2015 UNIFORM PLUMBING CODE (UPC)
2016 CALIFORNIA ENERGY CODE, PART 6, TITLE 24 CCR
2007 SAFETY CODE FOR ELEVATORS AND ESCALATORS
(ASME A17.1-2007)
2016 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24, CCR
BASED ON THE 2015 INTERNATIONAL FIRE CODE (IFC)
2016 CALIFORNIA EXISTING BUILDING CODE, PART 10, TITLE 24 CCR
(2015 IEB CODE AND CALIFORNIA AMENDMENTS)
2016 CALIFORNIA GREEN BUILDING CODE (CALGreen), PART 11, TITLE 24, CCR
2016 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 CCR
TITLE 19 CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS 2016 EDITION
NFPA 14 INSTALLATION OF STANDPIPE SYSTEMS 2013 EDITION
NFPA 17 STANDARD FOR DRY CHEMICAL EXTINGUISHING SYS. 2013 EDITION
NFPA 17A STANDARD FOR WET CHEMICAL SYS. 2013 EDITION
NFPA 20 INSTALLATION OF STATIONARY PUMPS 2016 EDITION
NFPA 24 INSTALLATION OF PRIVATE FIRE MAINS 2016 EDITION
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2016 EDITION
NFPA 80 FIRE DOORS AND OTHER OPENING PROTECTIVES 2016 EDITION
NFPA 92 STANDARD FOR SMOKE CONTROL SYSTEMS 2015 EDITION
NFPA 253 CRITICAL RADIANT FLUX OF FLOOR COVERING SYS 2015 EDITION
NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEM 2015 EDITION
REFERENCE CODE SECTIONS FOR APPLICABLE STANDARDS - 2016 CBC CHAPTER 35 AND
2016 CFC CHAPTER 45
THE ABOVE CODES AND REGULATIONS REFER TO THE LATEST EDITION OR REVISION IN
FORCE ON THE DATE OF THE CONTRACT, UNLESS OTHERWISE STATED. NOTHING ON THE
DRAWINGS IS TO BE CONSTRUED AS REQUIRING OR PERMITTING WORK THAT IS
CONTRARY TO THE LISTED CODES AND REGULATIONS, OR OTHER LOCAL, STATE OR
FEDERAL CODES OR REGULATIONS WHICH MAY BE APPLICABLE.
COMPLIANCE WITH CFC CHAPTER 33, FIRE SAFETY DURING CONSTRUCTION AND
DEMOLITION, AND CBC CHAPTER 33, SAFETY DURING CONSTRUCTION WILL BE
ENFORCED.
ABBREVIATIONS GENERAL NOTESSYMBOLS APPLICABLE CODES CONTACTS INDEX OF DRAWINGS
SCOPE OF WORK
TWELFTH FLOOR
VICINITY MAP
BUILDING DATA
F.D. FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER
CABINET
F.H.C. FIRE HOSE CABINET
FIN. FINISH
FLASH. FLASHING
FLR. FLOOR
FLUOR. FLUORESCENT
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUDS
FT. FOOT OR FEET
FTG. FOOTING
FURR. FURRING
G.A. GRAB BAR
GA. GAUGE
GALV. GALVANIZED
GND. GROUND
H.B. HOSE BIB
H.C. HOLLOW CORE
HDWD. HARDWOOD
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HR. HOUR
HT. HEIGHT
I.D. INSIDE DIAMETER
INSUL. INSULATION
INT. INTERIOR
JAN JANITOR
JT JOINT
MAX. MAXIMUM
MECH. MECHANICAL
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MTL. METAL
N. NORTH
N.I.C. NOT IN CONTRACT
NO. OR # NUMBER
NOM. NOMINAL
N.T.S. NOT TO SCALE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
OFF. OFFICE
OPNG. OPENING
OPP. OPPOSITE
PL. PLATE
PLAS. PLASTER
P.LAM. PLASTIC LAMINATE
PLYWD. PLYWOOD
PTD. PAINTED
PTN. PARTITION
PVC POLYVINYL CHLORIDE
RAD. RADIUS
R.D. ROOF DRAIN
REF. REFERENCE
REINF. REINFORCED
REQ. REQUIRED
RM. ROOM
R.O. ROUGH OPENING
R.W.L. RAIN WATER LEADER
S.C. SOLID CORE
SCHED. SCHEDULE
SECT. SECTION
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION
SQ. SQUARE
SS. STAINLESS STEEL
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRL. STRUCTURAL
SUSP. SUSPENDED
THK. THICK
T.O.C. TOP OF CURB
T.O.P. TOP OF PARAPET
T.O.R. TOP OF ROOF
T.O.W. TOP OF WALL
TRD. TREAD
TYP. TYPICAL
U.N.O. UNLESS NOTED
OTHERWISE
VERT. VERTICAL
VEST. VESTIBULE
W.W.M. WOVEN WIRE MESH
w/ WITH
W.C. WATER CLOSET
WD. WOOD
W/O WITHOUT
WP. WATERPROOF
WSCT. WAINSCOT
WT. WEIGHT
& AND
< ANGLE
@ AT
CENTERLINE
[ CHANNEL
Ø DIAMETER OR ROUND
FLOOR LINE
// PARALLEL
丄 PERPENDICULAR
# POUND OR NUMBER
PROPERTY LINE
ABV. ABOVE
A.B. ANCHOR BOLT
ACC. ACESSSIBLE OR
ACCESSIBILITY
ACOUS. ACOUSTICAL
ACP SUSPENDED ACOUSTIC
PANEL CEILING
ACT ACOUSTIC PANEL
CEILING
A.C. ASPHALTIC CONCRETE
ADD. ADDITIONAL
ADJ. ADJACENT
A.D. AREA DRAIN
A.F.F. ABOVE FINISHED FLOOR
AGGR. AGGREGATE
AL/ALUM. ALUMINIUM
ALT. ALTERNATE
AMEN. AMENITIES
ANOD. ANODIZED
A.P. ACESS PANEL
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
ASB. ASBESTOS
ASPH. ASPHALT
BD. BOARD
BITUM. BITUMINOUS
BLDG. BUILDING
BLKG. BLOCKING
BM. BEAM OR BENCH MARK
BOT. BOTTOM
CAB. CABINET
C.B. CATCH BASIN
CEM. CEMENT
CER. CERAMIC
C.I. CAST IRON
C.J. CONTROL JOINT
CL./CLR. CLEAR
CLG. CEILING
CLKG. CAULKING
CLO. CLOSET
COL. COLUMN
COMPT. COMPACTOR
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CTR. CENTER
DBL. DOUBLE
DEPT. DEPARTMENT
DET./DTL. DETAIL
DIA. DIAMETER
DIM. DIMENSION
DIV. DIVISION
DN. DOWN
DR. DOOR
DWG. DRAWING
E.A. EXPANSION JOINT
E.F.S. EXTERIOR INSULATED
FINSH SYSTEM
EA. EACH
EL. ELEVATION
ELEC. ELECTRICAL
ELEV. ELEVATOR
EMER. EMERGENCY
ENCL. ENCLOSURE
EQ. EQUAL
EQUIP. EQUIPMENT
EXP. EXPANSION
EXST. EXISTING
EXT. EXTERIOR
F.A. FIRE ALARM
12TH FLOOR
OCCUPANCY GROUP: 'B' - A BUILDING OR STRUCTURE, OR A PORTION THEREOF,
FOR OFFICE, PROFESSIONAL OR SERVICE - TYPE TRANSACTIONS, INCLUDING
STORAGE OF RECORDS AND ACCOUNTS, AND EATING AND DRINKING
ESTABLISHMENTS WITH AN OCCUPANT LOAD LESS THAN 50.
AREA SQ. FT. LOAD FACTOR OCCUPANTS
ARCHITECT
HIBSER YAMAUCHI ARCHITECTS, INC. TEL. (510) 446-2222
300 27TH STREET FAX. (510) 446-2211
OAKLAND, CA 94612
CONTACT: NINA IDZERDA
PROJECT MANAGER
CBRE TEL. (510) 874-1944
PROJECT MANAGEMENT FAX. (510) 834-9158
555 12TH STREET SUITE 900
OAKLAND, CA 94607
CONTACT: PATRICK TAHARA
EXITS
12TH FLOOR 24,000 100 240 2
- EXPANSION OF THE 12TH FLOOR CONFERENCE ROOM
- RELOCATION OF THE BREAK ROOM, WORK ROOM, (2) OFFICES
- CREATION OF (4) ROOMS FROM (2) LARGER EXISTING ROOMS
- EXPANSION OF OPEN OFFICE SPACE ADJACENT TO CONFERENCE ROOM
N
A
A3.01
A3.01
A5.01
A
C
D
CORR
CORRD
CORR
CORRD
DOOR SYMBOL
AREA OF NO WORK
SHEETNOTE TAG
REVISIONS
BUILDING OR WALL SECTION
INTERIOR ELEVATION(S)
DETAIL
BUILDING ELEVATION
ROOM IDENTIFICATION (TYPE 2)
ROOM IDENTIFICATION (TYPE 1)
(N) DOOR & DOOR FRAME
(E) DOOR TO REMAIN
(E) DOOR TO BE REMOVED
REFER TO SHEETNOTE LIST
LOCATED ON PLAN SHEETS
ELEVATION NOT SHOWN
DETAIL NO. OF ELEVATION
OR DATUM POINT
REVISION NUMBER
WORK POINT, CONTROL POINT
SECTION IDENTIFICATION
DETAIL IDENTIFICATION
SHEET WHERE DETAIL IS SHOWN
NO ARROWS MEAN
SHEET WHERE ELEVATION
IS SHOWN
( - MEANS DETAIL SHOWN ON
SAME SHEET)
SHEET WHERE SECTION
IS SHOWN
ELEVATION IDENTIFICATION
SHEET WHERE ELEVATION
IS SHOWN
COLUMN LINE
SEE DOOR SCHEDULE
DOOR MARK
9'-0"
ROOM NUMBER
ROOM NUMBER
KAISER ROOM CODE NAME
CEILING HEIGHT (OTHER THAN
EXISTING OR 8'-0" A.F.F.)
ROOM NAME
KAISER ROOM CODE NAME
ROOM NAME
A3.01
ELEVATION IDENTIFICATION
ARCHITECTURAL
A0.01 TITLE SHEET
A1.01 ACCESSIBLE PATH OF TRAVEL
A2.01 DEMOLITION PLAN
A2.11 IMPROVEMENT PLAN
A5.01 INTERIOR ELEVATIONS
A6.01 DEMOLITION RCP
A6.11 IMPROVEMENT RCP
A9.01 INTERIOR DETAILS
A9.02 INTERIOR DETAILS
1. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SEE TO IT THAT ALL
MATERIALS AND/OR WORK DESCRIBED, DEPICTED OR DETAILED WITHIN THESE
DOCUMENTS, BE FURNISHED AND OR INSTALLED REGARDLESS OF THE LOCATION OF THAT
MATERIAL OR WORK WITHIN THE DOCUMENTS OR OMISSION (WHETHER DELIBERATE OR
ACCIDENTAL) OF THAT MATERIAL OR WORK BY A SUBCONTRACTOR ON HIS/HER BID.
2. ALL CONTRACTORS, WHETHER THE GENERAL OR SUB, SHALL CONSIDER THESE
DOCUMENTS IN THEIR ENTIRETY. DISCREPANCIES OR CONTRADICTIONS BETWEEN
PORTIONS OF THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT AT LEAST 48 HRS PRIOR TO BID OPENING FOR CLARIFICATION. OTHERWISE
EITHER DESCRIPTION OR INSTRUCTION SHALL BE IN FORCE UNTIL ONE IS OMITTED BY THE
ARCHITECT, AT NO ADDITIONAL COST TO THE OWNER.
3. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND MAINTAINING TEMPORARY
FENCING AND GATES, SIGNAGE, SECURITY LIGHTING OR OTHER SECURITY AND CONTROL
MEASURES NECESSARY TO PROVIDE FOR THE SAFETY OF STUDENTS, FACULTY AND STAFF
AROUND THE WORK, UNTIL THE COMPLETION OF THE WORK UNLESS OTHERWISE
DETERMINED BY THE ARCHITECT OR CONSTRUCTION MANAGER.
4. THE CONTRACTOR IS RESPONSIBLE TO REPAIR AND/OR REPLACE ALL DISTRICT PROPERTY
DAMAGED DURING THE COURSE ON THE WORK, ESPECIALLY BUT NOT LIMITED TO ASPHALT
PAVING AROUND THE SITE, STAGING AREA OR PATH OF TRAVEL TO EITHER.
5. THE CONTRACTOR SHALL LIMIT HIS/HER ACTIVITY TO THE AREA DESCRIBED WITHIN THE
DOCUMENTS SO AS TO LIMIT HIS/HER LIABILITY FOR DAMAGED PROPERTY UNLESS
OTHERWISE PERMITTED BY THE CONSTRUCTION MANAGER OR OWNER.
6. ALL WORK SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF ALL APPLICABLE CODES.
SEE LIST THIS SHEET.
7. CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS PRIOR TO
COMMENCEMENT OF CONSTRUCTION EXCEPT DSA APPROVAL.
8. ALL DIMENSIONS SHALL BE FACE OF STUD, UNLESS OTHERWISE NOTED. DIMENSIONS
NOTED AS "CLR" MEAN CLEAR DIMENSION TO FACE OF FINISH. VERIFY ALL EXISTING
DIMENSIONS AND CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES FOUND.
9. ALL ITEMS IN THESE DRAWINGS ARE NEW UNLESS OTHERWISE NOTED.
10. SCHEDULE ALL WORK OUTSIDE THE "EXTENT OF WORK" SET FORTH IN THESE DOCUMENTS
WITH THE CONSTRUCTION MANAGER INCLUDING ACCESS AND STORAGE. THE
CONSTRUCTION SCHEDULE SHALL BE APPROVED BY THE OWNER PRIOR TO THE START OF
CONSTRUCTION.
11. ALL UTILITIES REQUIRED FOR THE CONTINUOUS OPERATION OF ALL EXISTING FACILITIES
TO REMAIN MUST BE MAINTAINED IN SERVICE AT ALL TIMES. ANY SHUT DOWNS FOR NEW
CONNECTIONS MUST BE COORDINATED WITH THE CONSTRUCTION MANAGER TWO WEEKS
PRIOR TO THE REQUESTED SHUT DOWN.
12. THE CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF ANY ITEMS
DAMAGED OR DISTURBED DURING THE COURSE OF THE WORK. INSTALLATION SHALL
MATCH EXISTING IN KIND, QUALITY, AND PERFORMANCE.
13. THE CONTRACTOR SHALL CONTAIN ALL DUST AND DEBRIS TO THE CONSTRUCTION AREA.
BROOM CLEAN ALL SIDEWALKS AND DRIVEWAYS EACH DAY. KEEP DIRT AND DUST TO A
MINIMUM.
14. ALL REMODELED ITEMS LISTED TO BE SALVAGED FOR THE OWNER SHALL BE DELIVERED
TO A PLACE OF STORAGE AS DIRECTED BY THE OWNER. ALL OTHER ITEMS MUST BE
DISPOSED OF OFF SITE IN A LEGAL MANNER.
15. ALL WORK SHALL BE EXECUTED IN A CAREFUL AND ORDERLY MANNER WITH THE LEAST
POSSIBLE DISTURBANCE TO THE PUBLIC AND TO OCCUPANTS OF EXISTING BUILDINGS.
16. THE CONTRACTOR SHALL ASSUME SOLE RESPONSIBILITY FOR THE SAFETY OF ALL
PERSONS ON OR ABOUT THE CONSTRUCTION SITE, IN ACCORDANCE WITH APPLICABLE
LAWS AND CODES. GUARD ALL HAZARDS IN ACCORDANCE WITH THE SAFETY PROVISIONS
OF THE LATEST MANUAL OF ACCIDENT PREVENTION PUBLISHED BY THE ASSOCIATED
GENERAL CONTRACTORS OF AMERICA.
A. COORDINATION WITH OTHER CONTRACTS: IF ANY PART OF THIS CONTRACTOR'S WORK
DEPENDS UPON THE WORK OF A SEPARATE CONTRACTOR, THIS CONTRACTOR SHALL
INSPECT SUCH OTHER WORK AND PROMPTLY REPORT IN WRITING TO THE
CONSTRUCTION MANAGER ANY DEFECTS IN SUCH OTHER WORK THAT RENDER IT
UNSUITABLE TO RECEIVE THE WORK OF THIS CONTRACTOR. FAILURE OF THIS
CONTRACTOR TO SO INSPECT AND REPORT SHALL CONSTITUTE AN ACCEPTANCE OF
THE OTHER CONTRACTOR'S WORK, EXCEPT AS TO DEFECTS WHICH MAY DEVELOP IN
OTHER CONTRACTOR'S WORK AFTER EXECUTION OF THIS CONTRACTOR'S WORK.
B. COORDINATION SCHEDULE: PORTIONS OF WORK UNDER THIS CONTRACTOR'S WORK
MUST BE COMPLETED ON SCHEDULE IN ORDER FOR OTHER NOT-IN-CONTRACT WORK TO
BE COMPLETED BY OTHERS. COORDINATION WITH THE CONSTRUCTION MANAGER AND
STRICT ADHERENCE TO THE COMPLETION DATES FOR DESIGNATED PORTIONS OF WORK
ARE IMPERATIVE. SEE SPECIFICATIONS FOR LIQUIDATED DAMAGES.
17. DEMOLITION IS NOT NECESSARILY LIMITED TO ONLY WHAT IS SHOWN ON THIS OR OTHER
DRAWINGS OR AS OUTLINED IN THE SPECIFICATIONS. THE INTENT IS TO INDICATE GENERAL
SCOPE OF DEMOLITION REQUIRED TO COMPLETE THE PROJECT WITH THE CONSTRUCTION
DOCUMENTS.
18. OF PARTICULAR IMPORTANCE IS THE NEED FOR CONTRACTOR TO ASSURE THAT ALL
PERSONS ENTERING A POSSIBLY HAZARDOUS AREA, INCLUDING SUPERINTENDENTS,
WORKERS, SUBCONTRACTORS, OTHER CONTRACTORS, AND OTHER PERSONS NOT UNDER
CONTRACTUAL CONTROL TO THE CONTRACTOR, ARE AWARE OF PROCEDURES.
19. SPECIAL ATTENTION IS CALLED TO THE REQUIREMENT OF THE CONTRACTOR TO COMPLY
WITH DSA REQUIREMENTS IN GENERAL AND WITH REGULATIONS INVOLVING ASBESTOS IN
PARTICULAR. THESE REGULATIONS ARE STATED IN SECTION 5208, ASBESTOS
REGULATIONS, OF TITLE 8, CALIFORNIA CODES OF REGULATIONS. THIS SECTION
STIPULATES THAT THE CONTRACTOR MUST INITIATE REPORTS, TESTS, SIGNS AND OTHER
ACTIVITIES UNDER CERTAIN JOB CONDITIONS.
20. STAGING AREA SHALL BE LOCATED WITHIN "EXTENT OF WORK" AREA.
21. ALL PIPE AND DUCT PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE FIRE
STOPPED AND SEALED TO MAINTAIN THE REQUIRED RATING.
22. DETAIL DRAWINGS WITH REFERENCES TO FIRE-RATED ASSEMBLIES OR CONSTRUCTION
WHICH HAVE BEEN TESTED BY UNDERWRITERS LABORATORIES, THE UNIFORM BUILDING
CODE OR ANY OTHER APPROVED TESTING AGENCY, SHALL BE CONSTRUED TO INDICATE
ALL CONSTRUCTION AND PROCEDURES CONTAINED IN THE REFERENCED ASSEMBLY FOR
CONSTRUCTION.
23. CONTRACTOR TO MAINTAIN RECORDED "AS-BUILT" INFORMATION ON ALL WORK INSTALLED
DURING CONSTRUCTION AND SHALL BE CLEARLY MARKED IN COLORED PENCIL ON A
REPRODUCIBLE PRINT OF SHOP DRAWINGS. THE CONTRACTOR SHALL TURN RECORDED
"AS BUILT" INFORMATION OVER TO OWNER'S REPRESENTATIVE IN THE FORM OF AUTOCAD
RELEASE 2000 OR NEWER ON CD-ROM, ALONG WITH ONE SET OF PLOTTED VELLUMS.
24. All ITEMS NEW, UNLESS OTHERWISE NOTED.
PROPERTY MANAGER
CBRE TEL. (510) 276-1126
BROADWAY FRANKLIN LLC
1111 BROADWAY
OAKLAND, CA 94607
CONTACT: TANICIA S. JACKSON
PRICING ALTERNATES
A1 TENANT ALTERNATE #1: PROVIDE FLOOR MOUNTED QUAD OUTLET AND
DATA. LOCATION TO BE VERIFIED WITH TENANT
A2 TENANT ALTERNATE #2: PROVIDE MOTORIZED FOLDING PARTITION
No. Revisions By Date Appr.
GENERAL PROJECT NOTES
1. THIS PROJECT SHALL BE DESIGN BUILD:
THE FOLLOWING CONTRACTORS SHALL PROVIDE SHOP DRAWINGS, MATERIALS
SPECIFICATIONS, AND SCHEDULES, WITH REQUIRED CALIFORNIA REGISTERED
ENGINEER'S SIGNATURES TO THE APPROPRIATE CITY DEPARTMENT(S) FOR PLAN
CHECK REVIEW PRIOR TO THE COMMENCEMENT OF WORK WHERE REQUIRED:
FIRE ALARM SUB CONTRACTOR
ELECTRICAL SUB-CONTRACTOR
MECHANICAL/PLUMBING SUB-CONTRACTOR
FIRE SPRINKLER SUB-CONTRACTOR
2. THE GENERAL CONTRACTOR SHALL PROVIDE ARCHITECT AND PLANNING
DEPARTMENT WITH SHOP DRAWINGS, MATERIAL SCHEDULES, AND SPECIFICATIONS
OF MATERIALS AND EQUIPMENT; AND WORKMANSHIP QUALITY, FOR CONTRACTOR'S
WORK, AND SUB-CONTRACTOR'S WORK, PRIOR TO THE COMMENCEMENT OF WORK.
3. THE ELECTRICAL CONTRACTOR IS REQUIRED TO SUBMIT TITLE 24 CALCULATIONS
AS PART OF THE DESIGN/BUILD SCOPE OF WORK.
4. THE FOLLOWING CONTRACTORS ARE TO SUBMIT AS-BUILTS W/ CERTIFICATION
THAT WORK CONFORMS TO DRAWINGS AND SPECIFICATIONS ELECTRICAL,
MECHANICAL/PLUMBING, FIRE SPRINKLER, AND FIRE ALARM SUBCONTRACTORS.
5. THE CONTRACTOR(S) SHALL PURCHASE AND MAINTAIN CERTIFICATES OF
INSURANCE WITH RESPECT TO WORKMAN'S COMPENSATION, PUBLIC LIABILITY AND
PROPERTY DAMAGE FOR THE LIMITS AS REQUIRED BY LAW. THE CONTRACTOR(S)
SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY
PRECAUTIONS IN CONJUNCTION WITH THE WORK.
6. THE CONTRACTOR IS RESPONSIBLE FOR PAYMENT AND OBTAINING OF ALL
PERMITS REQUIRED FOR THE PROJECT.
7. NO WORK DEFECTIVE IN CONSTRUCTION OR QUALITY WILL BE ACCEPTABLE IN
CONSEQUENCE OF THE OWNER'S OR ARCHITECT'S FAILURE TO DISCOVER OR POINT
OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION. DEFECTIVE WORK
REVEALED WITHIN THE TIME REQUIRED BY GUARANTEES SHALL BE REPLACED BY
WORK CONFORMING WITH THE INTENT OF THE CONTRACT. NO PAYMENT, EITHER
PARTIAL, OR FINAL, SHALL BE CONSTRUED AS AN ACCEPTANCE OF DEFECTIVE WORK
OR IMPROPER MATERIALS.
8. THE ARCHITECT WHO SIGNS AND STAMPS PLANS, SPECIFICATIONS, OR
DOCUMENTS WILL NOT BE RESPONSIBLE FOR DAMAGE CAUSED BY SUBSEQUENT
CHANGES TO OR USES OF THOSE PLANS, SPECIFICATIONS, DOCUMENTS, WHERE THE
SUBSEQUENT CHANGES OR USES, INCLUDING CHANGES OR USES MADE BY STATE
OR LOCAL GOVERNMENTAL AGENCIES, ARE NOT AUTHORIZED OR APPROVED BY THE
ARCHITECT WHO ORIGINALLY SIGNED THE PLANS, SPECIFICATIONS, OR DOCUMENTS.
9. THE SIGNING AND STAMPING OF PLANS, SPECIFICATIONS, OR DOCUMENTS WHICH
RELATE TO THE DESIGN OF FIXED WORKS SHALL NOT IMPOSE A LEGAL DUTY OR
RESPONSIBILITY UPON THE PERSON SIGNING THE PLANS, SPECIFICATIONS, OR
DOCUMENTS TO OBSERVE THE CONSTRUCTION OF THE FIXED WORKS WHICH ARE
THE SUBJECT OF THE PLANS, SPECIFICATIONS, OR DOCUMENTS.
10. ALL DESIGN/BUILD WORK SHALL CONFORM TO 180 GRAND BUILDING STANDARDS.
DRAWINGS MUST BE SUBMITTED TO BUILDING MANAGEMENT FOR REVIEW &
APPROVAL PRIOR TO SUBMITTING FOR PERMIT.
11. ALL (N) AND RE-INSTALLED POWER & DATA SWITCHES AND OUTLETS TO MATCH
COLOR OF (E) DEVICES.
AREA 1
AREA 2
BUILDING STORAGE
STORAGE
BUILDING
STORAGE
GAS ROOM
FOUNTAIN
PUMP ROOM
AREA
PITS
ELEV.
SVC.
ELEV.
SVC.
LOBBY
PITS
ELEV. MAIN TEL. RM.
MAIN ELECTRICAL ROOM
LOBBY
PARKING
ELEV.
#1 & #2
STAIR #1 STAIR #4
STAIR #5
STORAGE
BUILDING
RAMP
STAIR #3
ELEV.
BUILDING
SHAFT #4
SHAFT #3
SHAFT #2
SHAFT #1
PARKING
PARKING LEVEL 1
A B.5 C D E F G H J K K.5 L M
12.9
12.3
B
HIGH RISE
LOBBY
ELEVATOR
LOW RISE
ELEVATOR
LOBBY
DN
UP
DN
HR1
P2
P1
HR2
HR3
HR4
HR5
SVC
SVC
LOBBY
ELEC.
LR3
LR2
LR1
TELE.
LR4
LR5
UP
LR6
MANAGEMENT
OFFICE
LOBBY
T H
S T R E E T
CLAY
STREET
T H
S T R E E T
BROADWAY
PEET'S
COFFEE
TOTAL NUMBER OF PARKING PROVIDED: 240
ACCESSIBLE PARKING: 7
VAN ACCESSIBLE PARKING: 1 *BUILDING MANAGEMENT HAS BEEN NOTIFIED THAT TOTAL
NUMBER OF VAN SPACES NEEDS TO BE 2. THEY WILL PERFORM THE REQUIRED UPGRADES.
A
ETE
C-27362
RENEWAL
O
S T
T A
CI
L
E
T
AI
N
C
RDATE
F LA IC
FO
ES
N I
CHD AR
E R
IB
. HUS A
A M
R
C S
01-31-2019
ISSUE DATE: BY:
1/16" = 1'-0"GRAPHIC SCALES:
5'0 50' 0 5'
1/8" = 1'-0" 1/4" = 1'-0"
25' 0 1' 12'
1/2" = 1'-0"
0 1' 6' 0
1" = 1'-0"3/4" = 1'-0"
4' 0 1'
1 1/2" = 1'-0"
03' 2' 0
A REDUCED PRINT SCALE ACCORDINGLY
IF THIS SHEET IS NOT 30"x42" , IT IS
3" = 1'-0"
1'
Client Project Number:
Sheet
Drawn By:
Checked By:
Revit Version:
Facility
Project
Sheet Title
Scale:
Sheet
HY Architects Project number:
Revisions#
This document is the property of the Owner and is not to be used without his written permission
Architect/Engineer Of Record:_________________________________________________
SL7/28/17
100% CONSTRUCTION
DOCUMENTS
of
Issue Date:
/2
/2
:0
:2
P M
C
R e v it L o c a ls \G
S A th
F lo o r
C o n fe re n c e
R o o m
R
V T s d o s ic k .r v t
1/16" = 1'-0"
SD
SL
12TH FLOOR CONFERENCE
ROOM
ACCESSIBLE PATH OF
TRAVEL
A1.01
1111 BROADWAY OAKLAND, CA 94607
Client Proj. #
Project Number
7/28/17 1/16" = 1'-0"
ACCESSIBLE PATH OF TRAVELACCESSIBLE PATH OF TRAVEL
ELEVATORS FROM
PARKING GARAGE
ACCESSIBLE ROUTE FROM
SIDEWALK
ACCESSIBLE ROUTE FROM
SIDEWALK
ACCESSIBLE PARKING VAN ACCESSIBLE
PARKING
N
LEGEND
ACCESSIBLE PATH OF TRAVEL
No. Revisions By Date Appr.
H
FSFE
H
FS
H H
FS
HHH HHH
FS
HH
J
J
T
T
J
T
H H
T
J
J
J
J
C
T
FSFS FS
C
FS
C
T
FS
FS
T
T
FE
J
J
C
C
C C.5 D D.5 E E.5 F F.5 G G.5 H H.5 J J.5 K K.5 L M
10.5
9.5
(RE)
(RE)
(RE) (RE) (RE) (RE)(RE)
(RE)
213 206
(RE)
215215215
206 206
+ 60" A.F.F.+ 60" A.F.F.
+ 60" A.F.F.
207207
FP B FP FP FP FP
FP FPFPFPFP
FP FP FP
FP FP
FP
(RE)
(RE)
218220
219219
B
B
B
B B
B
(RE)
(RE)(RE)
223222
225 230 229 226 227
(E) WALL MOUNTED DUPLEX TO REMAIN
(E) WALL MOUNTED DUPLEX TO BE REMOVED
(E) HIGH WALL MOUNTED DUPLEX @ 8'-0" A.F.F. TO REMAIN
(E) HIGH WALL MOUNTED DUPLEX @ 8'-0" A.F.F. TO BE REMOVED
(E) DUPLEX FLOOR MONUMENT TO REMAIN
FACE PLATE AT (E) DUPLEX FLOOR MONUMENT TO BE REMOVED
(E) QUAD FLOOR MONUMENT TO REMAIN
FACE PLATE AT (E) QUAD FLOOR MONUMENT TO BE REMOVED
(E) WALL MOUNTED FIRE STROBE TO REMAIN
(E) WALL MOUNTED FIRE STROBE TO BE REMOVED
(E) WALL MOUNTED THERMOSTAT TO REMAIN
(E) WALL MOUNTED THERMOSTAT TO BE REMOVED OR RELOCATED
(E) WALL MOUNTED HDMI TO REMAIN
(E) WALL MOUNTED HDMI TO BE REMOVED
(E) WALL MOUNTED FIRE EXTINGUISHER CABINET TO REMAIN
WALL TYPES
(E) CEILING HEIGHT NON-RATED PARTITION TO REMAIN
(E) CEILING HEIGHT NON-RATED PARTITION TO BE REMOVED
DOOR & WINDOW TYPES
(E) DOOR, FRAME & HARDWARE TO REMAIN
POWER & DATA
(E) FULL HEIGHT 1-HR RATED WALL TO BE REMOVED
(E) FULL HEIGHT 1-HR RATED WALL TO REMAIN
(E) DOOR, FRAME & HARDWARE TO BE RELOCATED OR REMOVED
ACCESSORIES
(RE) DENOTES ITEM TO BE RELOCATED
H
H
(E) J - BOX TO REMAIN
(E) J - BOX TO BE REMOVED
(E) ITEM TO BE REMOVED
AREA OF NO WORK
(E) WALL MOUNTED DUPLEX TO REMAIN
(E) WALL MOUNTED DUPLEX TO BE REMOVED
(E) HIGH WALL MOUNTED DUPLEX @ 8'-0" A.F.F. TO REMAIN
(E) HIGH WALL MOUNTED DUPLEX @ 8'-0" A.F.F. TO BE REMOVED
H
H
FINISHES
DEMO (E) CARPETING AND PREP SLAB FOR NEW FLOORING
PER IMPROVEMENT PLAN
DEMO (E) VCT AND PREP SLAB FOR NEW FLOORING PER
IMPROVEMENT PLAN
FP
FP
(E) FULL HEIGHT NON- RATED WALL TO REMAIN
(E) WALL MOUNTED CAMERA TO REMAIN
(E) WALL MOUNTED CAMERA TO BE REMOVED OR RELOCATED PER
TENANT'S INSTRUCTIONS
REPLACE (E) QUAD FLOOR MONUMENT WITH NEW BRASS MONUMENT
B
ETE
C-27362
RENEWAL
O
S T
T A
CI
L
E
T
AI
N
C
RDATE
F LA IC
FO
ES
N I
CHD AR
E R
IB
. HUS A
A M
R
C S
01-31-2019
ISSUE DATE: BY:
1/16" = 1'-0"GRAPHIC SCALES:
5'0 50' 0 5'
1/8" = 1'-0" 1/4" = 1'-0"
25' 0 1' 12'
1/2" = 1'-0"
0 1' 6' 0
1" = 1'-0"3/4" = 1'-0"
4' 0 1'
1 1/2" = 1'-0"
03' 2' 0
A REDUCED PRINT SCALE ACCORDINGLY
IF THIS SHEET IS NOT 30"x42" , IT IS
3" = 1'-0"
1'
Client Project Number:
Sheet
Drawn By:
Checked By:
Revit Version:
Facility
Project
Sheet Title
Scale:
Sheet
HY Architects Project number:
Revisions#
This document is the property of the Owner and is not to be used without his written permission
Architect/Engineer Of Record:_________________________________________________
SL7/28/17
100% CONSTRUCTION
DOCUMENTS
of
Issue Date:
/2
/2
:0
:2
P M
C
R e v it L o c a ls \G
S A th
F lo o r
C o n fe re n c e
R o o m
R
V T s d o s ic k .r v t
As indicated
SD
SL
12TH FLOOR CONFERENCE
ROOM
DEMOLITION PLAN
A2.01
1111 BROADWAY OAKLAND, CA 94607
Client Proj. #
Project Number
7/28/17
1. TENANT TO PROVIDE & INSTALL ALL FURNITURE & EQUIPMENT AS SHOWN.,
U.O.N
2. (N) PAINT THROUGHOUT AS INDICATED ON FINISH LEGEND AND FLOOR PLAN.
3. (E) BLINDS @ EXTERIOR TO REMAIN, TYP., U.O.N.
4. PATCH AND REPAIR (E) WALLS WHERE REQUIRED FOR (N) FINISHES PER
BUILDING STANDARDS.
5. ALL NEW HARDWARE TO MATCH (E).
6. SEE A2.11 FOR DOOR NOTES & HARDWARE GROUPS.
7. WHERE EXISTING CONSTRUCTION IS OR HAS BEEN CUT, DAMAGED, OR
REMODELED, PATCH WITH MATERIALS TO MATCH IN KIND, QUALITY AND
PERFORMANCE.
8. WORK SHALL BE EXECUTED IN A CAREFUL AND ORDERLY MANNER WITH THE
LEAST POSSIBLE DISTURBANCE TO PUBLIC AND TO OCCUPANTS OF BUILDING.
9. ALL REMOVED ITEMS DEEMED TO HAVE VALUE BY THE OWNER SHALL BE
DELIVERED TO A PLACE OF STORAGE IN THE BUILDING AS DIRECTED. ALL OTHER ITEMS
MUST BE DISPOSED OF OFF SITE IN A LEGAL MANNER.
10. CONTRACTOR RESPONSIBLE FOR PROTECTING ALL (E) ITEMS TO REMAIN.
11. CONTRACTORS & SUBS TO BE RESPONSIBLE FOR CHECKING CONTRACT
DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS FOR ACCURACY AND CONFIRMING
THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH PRICING OR
CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE OR OTHER
COORDINATION QUESTIONS, THE CONTRACTOR SHALL CONTACT BUILDING ARCHITECT/
BUILDING ENGINEER BEFORE PROCEEDING WITH THE WORK IN QUESTION.
12. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT AND
FIXTURES AS REQUIRED FOR NEW WORK.
13. REPAIR ALL EXISTING-TO-REMAIN PARTITIONS AFFECTED BY DEMOLITION.
PROVIDE A SEAMLESS FINISH.
14. TENANT TO REMOVE (E) FURNITURE, U.O.N.
15. RELOCATE FIRE ALARM DEVICES PER BUILDING CODE.
1/8" = 1'-0"
DEMOLITION PLANDEMOLITION PLAN
N
GENERAL NOTES SHEET NOTES
LEGEND
201 DEMO (E) UPPER AND LOWER CASEWORK, P.LAM COUNTER, AND SINK.
206 REMOVE (E) WALL MOUNTED CONFERENCE TV AND RELOCATE PER
IMPROVEMENT PLAN
207 REMOVE (E) CARD READER AND PATCH AND REPAIR WALL AS NEEDED.
RELOCATE CARD READER PER IMPROVEMENT PLAN
208 REMOVE (E) DISHWASHER
211 DEMO (E) LOWER CASEWORK, COUNTER, AND SUPPORTS
212 REMOVE (E) FOLDING PARTITION
213 DEMO (E) UPPER & LOWER CASEWORK, COUNTER, AND SUPPORTS
214 (E) VCT MOVABLE SHELVES AND TRACKS. PATCH AND REPAIR SLAB
215 REMOVE (E) WALL MOUNTED OFFICE TV AND RELOCATE PER
IMPROVEMENT PLAN
217 REMOVE (E) P. LAM. COUNTER AND LOWER CABINETRY
218 REMOVE (E) OCCUPANCY SIGN AND PATCH AND REPAIR WALL AS
NEEDED. RELOCATE SIGN PER IMPROVEMENT PLAN
219 REMOVE (E) FEMA SIGN AND PATCH AND REPAIR WALL AS NEEDED.
RELOCATE SIGN PER NEW LOCATION. LOCATION TO BE PROVIDED BY
TENANT
220 (E) OCCUPANCY SIGN TO REMAIN
221 RELOCATE (E) CLOCK PER IMPROVEMENT PLAN
222 REUSE DOOR AT 1228A
223 REUSE DOOR AT 1228B
224 REUSE DOOR AT 1228C
225 REUSE DOOR AT 1202
226 REUSE DOOR AT 1204
227 REUSE DOOR AT 1205
228 REUSE DOOR AT 1212
229 REUSE DOOR AT 1220
230 REUSE DOOR AT 1210A
231 REUSE DOOR AT 1208DA
FSFE
H H
FS
J
T
HHHH
H H
H H
H H
H H
T
FS
T
H H
C
T T
T
T
J
J
J
J
J
J
J
J
J
J
FS
FS
T
T
FE
J
J
C
C C.5 D D.5 E E.5 F F.5 G G.5 H H.5 J J.5 K K.5 L M
10.5
9.5
OFFICE
OFFICE
CONFERENCE
OFFICE
OFFICE
OFFICE
1210A
OFFICE
1210B
MEETING
MEETING
OFFICE
OFFICE
LUNCH ROOM
1228B
CONFERENCE
ROOM
1228A
CONFERENCE
ROOM
1228C
CONFERENCE
ROOM
LOBBY
21' - 6 1/2"19' - 6"
STORAGE
WORK
12131
OFFICE
OFFICE
5' - 0"
ELEVATOR
LOBBY
(RE)
B
B
A
AC
C
C
OC
OC
FP FP FP FP FP
FP FPFPFPFP
FP FP FP
+ 56" A.F.F.
N
OC
N
OC
+ 52" A.F.F.
N N
N
N
NN
N
N
N
N
N
+ 42" A.F.F.
AV
N N
N
N
N
N
N
N
N
N
OPEN OFFICE
1208D
CORRIDOR
1208E
12201212
1210A
1210B
1208Db
1228B1228A
1208E
1229A
1208Da
1229B
(RE) (RE)
(RE)
(RE)
(RE)
(RE) (RE)
NN
N
N
(RE)
(RE)
FP FP
FP
A5.01 B
A5.01 D B
A5.01
C
N
N
+ 60" A.F.F.
N
+ 60" A.F.F.+ 60"
A.F.F.
+ 42" A.F.F.
+ 42" A.F.F.
+ 42" A.F.F.
N
N
N
+ 56" A.F.F.
B-1
C-1
PT-1
B-1 C-1
PT-1
B-1
RF-1
PT-1
B-1
C-1
PT-1
B-1
C-1
PT-1
B-1
C-1
PT-1
B-1 C-1
PT-1
B-1
RF-1
PT-1
B-1
RF-1
PT-1
B-1
C-1
PT-1
B-1
C-1
PT-1
B-1
C-1
PT-1
B-1
C-1
PT-1
B-1 C-1
PT-1
B-1
C-1
PT-1
B-1
C-1
PT-1
12' - 2"
10' - 5" 10' - 5 1/2"
/4
10' - 4" 10' - 5" 9' - 11 1/2" 24' - 10"
18' - 9" 17' - 9 1/4"
OPEN OFFICE
1208C
OPEN OFFICE
1208F
B-1 C-1
PT-1
OCOC
N
N
N
N + 42" A.F.F.
+ 42" A.F.F.
OC
OC
N
N
OC
N
OC
N
OC
OC
OC
OC
OC
OC
N
N
C
OC
OC
OC
OC
N
N
B
C
C
C
N
265265
+ 50" A.F.F.
+ 50" A.F.F.
+ 50" A.F.F.
(RE) (RE)
1228C
266266
OC
N
D
D
D
275275
OC
19' - 6"10' - 2 3/4"16' - 7 1/2"
ALIGN
ALIGN
A L
IG
N
B
B
B
B
B B
B
A1
(RE)(RE)
N N
N
24' - 10" N
OC
N N
A2 A2
(E) WALL MOUNTED DUPLEX
WALL MOUNTED DUPLEX
(E) HIGH WALL MOUNTED DUPLEX @ 8'-0" A.F.F.
HIGH WALL MOUNTED DUPLEX @ 8'-0" A.F.F.
(E) FLOOR MOUNTED DUPLEX
FLOOR MOUNTED DUPLEX
(E) FLOOR MOUNTED QUAD
FLOOR MOUNTED QUAD
(E) WALL MOUNTED FIRE STROBE
WALL MOUNTED FIRE STROBE
(E) WALL MOUNTED THERMOSTAT
WALL MOUNTED THERMOSTAT
(E) WALL MOUNTED HDMI
WALL MOUNTED HDMI
(E) WALL MOUNTED FIRE EXTINGUISHER CABINET
WALL TYPES
(E) CEILING HEIGHT NON-RATED PARTITION
CEILING HEIGHT NON-RATED PARTITION, SEE 4/A9.01
DOOR & WINDOW TYPES
POWER & DATA
FULL HEIGHT 1-HR RATED WALL, SEE 15/A9.01
(E) FULL HEIGHT 1-HR RATED WALL
ACCESSORIES
H
H
(E) WALL MOUNTED J - BOX
POWER AND DATA FEED FOR ELECTRIFIED WORKSTATIONS.
WORKSTATIONS WILL HAVE CONTROLLED OUTLETS IN ADDITION
TO STANDARD OUTLETS
AREA OF NO WORK
FULL HEIGHT NON-RATED PARTITION, SEE 10/A9.01
A
B
C
N
N
N
N
N
(E) DOOR, FRAME & HARDWARE
(N) OR (RE) DOOR TO MATCH (E).
(N) TEMPERED GLASS SIDELIGHT INTEGRAL
TO DOOR FRAME PER BUILDING STANDARS, W.O.
# DOOR MARK
NOTE: SEE DOOR SCHEDULE
FOR MORE INFORMATION
N
N
N
DENOTES RELOCATED ITEM(RE)
(E) WALL MOUNTED DUPLEX
WALL MOUNTED DUPLEX
(E) HIGH WALL MOUNTED DUPLEX @ 8'-0" A.F.F.
HIGH WALL MOUNTED DUPLEX @ 8'-0" A.F.F.
H
H
N
N
AV INPUTAV
FLOOR MOUNTED QUAD OUTLET AND DATA.
PROVIDE BLANK BRASS FACEPLATE @ (E) DUPLEX FLOOR MONUMENT
FP
PROVIDE BLANK BRASS FACEPLATE @ (E) QUAD FLOOR MONUMENT
FP
FINISHES
CARPETING TO MATCH (E) PER FINISH LEGEND
LUXURY VINYL TILE TO MATCH (E) PER FINISH LEGEND
WALL MOUNTED QUAD OUTLET WITH 2 STANDARD RECEPTACLES
AND 2 CONTROLLED RECEPTACLES PER TITLE 24. CONTROLLED
RECEPTACLES TO HAVE PERMANENT MARKING & BLACK COLOR
(SIMILAR TO LEVITON 5362-1PE) TO BE VERIFIED W/BLDG. ENGINEER.
OC
REPLACE (E) QUAD FLOOR MONUMENT WITH NEW BRASS
MONUMENT
B
FULL HEIGHT EXTENSION NON-RATED PARTITION, SEE 3/A9.01
D
(E) WALL MOUNTED THERMOSTAT
PT-1 PAINT (TYPICAL THROUGHOUT)
MANUFACTURER: KELLY MOORE PAINTS
COLOR: WESTERN ACOUSTIC
FINISH:
C-1 CARPET (TYPICAL THROUGHOUT)
MANUFACTURER: SHAW
STYLE/PATTERN: 5T064 AUGMENT TILE 24" X 24"
COLOR: 64150 “INSPIRE”
B-1 RUBBER BASE (TYPICAL THROUGHOUT)
MANUFACTURER: JOHNSONITE
COLOR: 440146010 "SEAWEED" 4"
RF-1 LUXURY VINYL TILE
MANUFACTURER: ARMSTRONG
STYLE/PATTERN: NATURAL CREATION, ARBOR ART
COLOR: TBD
PL-1 PLASTIC LAMINATE - CABINETS
MANUFACTURER: FORMICA
COLOR: TBD
PL-2 PLASTIC LAMINATE - COUNTERTOP
MANUFACTURER: FORMICA
COLOR: TBD
GENERAL NOTES:
A) ALL DOOR LEVERS SHALL BE SCHLAGE L SERIES, 17A LEVER, FINISH 625
B) ALL DOORS LISTED ON SCHEDULE ABOVE ARE (N). U.O.N.
1. DOOR & FRAME TYPES:
2. THICKNESS: MATCH (E) U.O.N.
3. DOOR MATERIAL: TYP = MATCH (E) IN SUITE
4. FACING AND FINISH: MATCH (E) U.O.N.
5. GLASS: TYP = MATCH (E) U.O.N.
6. REFER TO HARDWARE SCHEDULE FOR HARDWARE GROUPS (VERIFY ALL LOCK FUNCTIONS WITH
BUILDING ENGINEER & TENANT):
QUANTITY DESCRIPTION MODEL # FINISH MFR.
4 EA HINGES 5BB1HW 4.5"X4" 625 IVE
1 SET OFFICE LOCKSET L9050 625 SCH
1 EA CLOSER 1461 626 LCN
1 EA DOME STOP FS13 625 IVE
HW-1 (HARDWARE GROUP 1):
QUANTITY DESCRIPTION MODEL # FINISH MFR.
3 EA HINGES 5BB1HW 4.5"X4" 625 IVE
1 EA ELECTRIC HINGE 5BB1HW 4.5"X4" TWB 625 IVE
(CONCEALED CONTACT HINGE)
1 SET ELECTRIC LOCK LV9080 EL 625 SCH
1 EA CLOSER 1461 626 LCN
1 EA DOME STOP FS13 625 IVE
1 SET SEALS 2525 BLK NGP
HW-3 (HARDWARE GROUP 3): CARD READER DOOR
A
A9.02
(AA DOUBLE) (BB DOUBLE)
B
A9.02
A9.02
MATCH (E)
2 3
WALL
INSIDE
QUANTITY DESCRIPTION MODEL # FINISH MFR.
4 EA HINGES 5BB1HW 4.5"X4" 625 IVE
1 SET OFFICE LOCKSET L9050 625 SCH
1 EA DOME STOP FS13 625 IVE
HW-2 (HARDWARE GROUP 2): OFFICE / MEETING
NOTES:
1. SPECIFIC MANUFACTURER'S BRAND NUMBERS ARE
LISTED IN THE BUILDING STANDARDS AS A QUALITY, FUNCTION
& APPEARANCE STANDARD.
2. ALL FINISHES SHALL BE PER BUILDING STANDARDS.
3. ALL LEVER RETURNS SHALL BE WITHIN 1/2" OF THE FACE
OF DOORS AS SHOWN BELOW.
FACE OF DOOR
LEVER OF LOCKSET / LATCHSET
1/2" MAX.
TYPICAL DETAIL
4. ALL LOCKSETS OR LATCHSETS SHALL BE PER SPECIFICATIONS
W/ LEVER CONFORMING TO CCR. TITLE 19 & 24 REQUIREMENTS.
CENTER LEVER BETWEEN 30" & 44" ABOVE FINISHED FLOOR.
5. ADJUST DOOR CLOSER FOR MAXIMUM PUSH/PULL EFFORT TO
OPERATE DOOR AS FOLLOWS: (EFFORT SHALL BE APPLIED AT RIGHT
ANGLES TO CENTER PLANE OF DOOR):
A. INTERIOR DOORS: NOT TO EXCEED 5 POUNDS.
B. FIRE RATED DOORS: NOT TO EXCEED 15 POUNDS.
6. SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT
FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT
LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES FROM THE LATCH,
MEASURED TO THE LEADING EDGE OF THE DOOR.
7. HARDWARE SHALL MATCH DOOR FIRE RATING.
8. ALL EXIT DOORS SHALL BE OPENABLE IN THE DIRECTION OF EXIT
TRAVEL AT ALL TIMES WITHOUT SPECIAL KNOWLEDGE OR EFFORT
AND WITHOUT LOCKING DEVICES.
9. RATING OF DOORS & FRAMES: TYP. = NON-RATED.
20 = 20MIN. RATING
10. ALL OFFICE DOORS AND STAFF AREA SHALL HAVE PASSAGE
STYLE LEVER HARDWARE, U.O.N. (MEETING ADA COMPLIANCE).
STORAGE ROOM DOORS TO HAVE LOCKABLE LEVER STYLE
HARDWARE (MEETING ADA COMPLIANCE) WITH MASTER KEY
(COORDINATE KEYING SCHEDULE WITH TENANT AND PROVIDE
FINISHED KEYS). ALL DOORS AND DOOR FRAMES TO BE BUILDING
STANDARD EXCEPT AS NOTED. THROUGHOUT SUITE UNLESS NOTED
OTHERWISE. SUBMIT SAMPLE MATERIALS AND FINISHES TO AOR FOR
APPROVAL.
11. VERIFY THAT ALL CLOSERS ON NEW AND EXISTING DOORS
COMPLY WITH ADA, TITLE III REQUIREMENTS INCLUDING MAXIMUM
OPENING FORCE OF 5 LBS AND MINIMUM CLOSING SWEEP PERIOD OF
3 SECONDS.
12. ALL HARDWARE TO BE BUILDING STANDARD, UON. FINISH -SATIN
NICKEL.
13. NEW DOORS TO MATCH BUILDING STANDARDS.
14. ALL HARDWARE TO BE (N) PER HARDWARE GROUP LISTED.
15. TENANT TO PROVIDE AND INSTALL ANY SECURITY DEVICES AND
HARDWARE AS NEEDED. TENANT AND THEIR SECURITY VENDOR TO
COORDINATE KEYING REQUIREMENTS WITH BUILDING MANAGEMENT.
ALL LOCKED DOORS NEED KEYS PER BUILDING STANDARD.
CONTRACTOR TO COORDINATE WITH TENANT AND BUILDING
MANAGEMENT THE LOCATIONS AND QUANTITY OF DOORS REQUIRING
ELECTRIFIED HARDWARE FOR PROPER RACEWAY CONDITIONS AT
NEW/ EXISTING DOORS. TENANT IS RESPONSIBLE FOR ANY
ADDITIONAL COSTS FOR SECURITY REQUIREMENTS BEYOND
BUILDING STANDARD.
ETE
C-27362
RENEWAL
O
S T
T A
CI
L
E
T
AI
N
C
RDATE
F LA IC
FO
ES
N I
CHD AR
E R
IB
. HUS A
A M
R
C S
01-31-2019
ISSUE DATE: BY:
1/16" = 1'-0"GRAPHIC SCALES:
5'0 50' 0 5'
1/8" = 1'-0" 1/4" = 1'-0"
25' 0 1' 12'
1/2" = 1'-0"
0 1' 6' 0
1" = 1'-0"3/4" = 1'-0"
4' 0 1'
1 1/2" = 1'-0"
03' 2' 0
A REDUCED PRINT SCALE ACCORDINGLY
IF THIS SHEET IS NOT 30"x42" , IT IS
3" = 1'-0"
1'
Client Project Number:
Sheet
Drawn By:
Checked By:
Revit Version:
Facility
Project
Sheet Title
Scale:
Sheet
HY Architects Project number:
Revisions#
This document is the property of the Owner and is not to be used without his written permission
Architect/Engineer Of Record:_________________________________________________
SL7/28/17
100% CONSTRUCTION
DOCUMENTS
of
Issue Date:
/2
/2
:0
:2
P M
C
R e v it L o c a ls \G
S A th
F lo o r
C o n fe re n c e
R o o m
R
V T s d o s ic k .r v t
As indicated
SD
SL
12TH FLOOR CONFERENCE
ROOM
IMPROVEMENT PLAN
A2.11
1111 BROADWAY OAKLAND, CA 94607
Client Proj. #
Project Number
7/28/17
1. TENANT TO PROVIDE & INSTALL ALL FURNITURE & EQUIPMENT AS SHOWN., U.O.N
2. (N) PAINT THROUGHOUT TO MATCH (E) THROUGHOUT SUITE.
3. (E) BLINDS @ EXTERIOR TO REMAIN, TYP., U.O.N.
4. PATCH AND REPAIR (E) WALLS WHERE REQUIRED FOR (N) FINISHES PER 1
BUILDING STANDARDS. NEW PAINT, BASE, VCT WHERE DAMAGED. PATCH
CARPET AND VCT IN ALL AREAS DAMAGED BY CONSTRUCTION.
5. ALL NEW HARDWARE TO MATCH (E).
6. PROVIDE REQUIRED LIFE SAFETY DEVICES THROUGHOUT SUITE PER BLDG.
STANDARD & CODE REQUIREMENTS.
7. WHERE EXISTING CONSTRUCTION IS OR HAS BEEN CUT, DAMAGED, OR
REMODELED, PATCH WITH MATERIALS TO MATCH IN KIND, QUALITY AND
PERFORMANCE.
8. WORK SHALL BE EXECUTED IN A CAREFUL AND ORDERLY MANNER WITH THE
LEAST POSSIBLE DISTURBANCE TO PUBLIC AND TO OCCUPANTS OF BUILDING.
9. ALL REMOVED ITEMS DEEMED TO HAVE VALUE BY THE OWNER SHALL BE
DELIVERED TO A PLACE OF STORAGE IN THE BUILDING AS DIRECTED. ALL OTHER
ITEMS MUST BE DISPOSED OF OFF SITE IN A LEGAL MANNER.
10. CONTRACTOR RESPONSIBLE FOR PROTECTING ALL (E) ITEMS TO REMAIN.
11. CONTRACTORS & SUBS TO BE RESPONSIBLE FOR CHECKING CONTRACT
DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS FOR ACCURACY AND
CONFIRMING THAT WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING WITH
PRICING OR CONSTRUCTION. IF THERE ARE ANY QUESTIONS REGARDING THESE
OR OTHER COORDINATION QUESTIONS, THE CONTRACTOR SHALL CONTACT
BUILDING ARCHITECT/ BUILDING ENGINEER BEFORE PROCEEDING WITH THE
WORK IN QUESTION.
12. REPAIR ALL EXISTING-TO-REMAIN PARTITIONS AFFECTED BY DEMOLITION.
PROVIDE A SEAMLESS FINISH.
13. ALL (N) ITEMS TO BE CONSTRUCTED TO BUILDING STANDARDS U.O.N.
14. MAINTAIN INTEGRITY OF EXISTING FIRE RATED PARTITIONS FOR ALL
PENETRATIONS.
15. FOR ACCESSIBLE CLR. SPACE REQ'D @ DOORS, SEE DET. 16/A9.01
16. ALL (N) AND RE-INSTALLED POWER & DATA SWITCHES AND OUTLETS TO MATCH
COLOR OF (E) DEVICES.
17. ALL DOORS WITHIN AREA OF WORK TO RECIEVE SIGNAGE PER DOOR SCHEDULE.
18. RELOCATE FIRE ALARM DEVICES PER BUILDING CODE.
1/8" = 1'-0"
IMPROVEMENT PLANIMPROVEMENT PLAN
GENERAL NOTES
LEGEND
N
SHEET NOTES
251 PROVIDE P. LAM. COUNTER AND LOWER CABINETRY
252 PROVIDE P. LAM. COUNTER AND UPPER AND LOWER CABINETRY
253 COPIER MACHINE N.I.C. PROVIDE 20 A DEDICATED CIRCUIT AND DATA
254 X-RAY MACHINE PROVIDED BY TENANT.
255 METAL DETECTOR PROVIDED BY TENANT
256 LOBBY DESK PROVIDED BY TENANT
257 FILES, N.I.C.
258 VENDING MACHINE PROVIDED BY TENANT
259 REFRIGERATOR PROVIDED BY TENANT
261 42" HIGH COUNTER
262 DISHWASHER
264 PROVIDE P.LAM COUNTER, UPPER AND LOWER CABINETRY,
ACCESSIBLE SINK AND GARBAGE DISPOSAL. PROVIDE INSTA-HOT
AND LEAK DETECTOR
265 MODERNFOLD MODEL #932, FULL-HEIGHT, ACOUSTICAL PARTITION -
APPROX. 29'-0" IN LENGTH, INCLUDING POCKET, TRACK AND
STRUCTURAL SUPPORT. SEE DETAIL 8/A9.02. PROVIDE NG-70 JAMB
AT DOOR END.
266 (RE) CARD READER
267 PROVIDE WALL MOUNTED DUPLEX 3" FROM CEILING
268 (RE) WALL MOUNTED CONFERENCE TV
269 (RE) WALL MOUNTED OFFICE TV
270 TO EXIT SIGN, SEE DETAIL 1/A9.02
271 EXIT ROUTE SIGN, SEE DETAIL 1/A9.02
273 (RE) OCCUPANCY SIGN
274 (RE) CLOCK
275 EXTEND (E) WALL TO DECK. ADD INSULATION FOR SOUND
ATTENUATION. SEE DETAIL 3/A9.01 FOR WALL EXTENSION TO DECK
AND DETAIL 10/A9.01 FOR SOUND ATTENUATION INSULATION
276 CONVERT (E) FURNITURE CIRCUIT TO ACCOMMODATE CONTROLLED
OUTLETS IN FURNITURE SYSTEM
A1 TENANT ALTERNATE #1: PROVIDE FLOOR MOUNTED QUAD OUTLET
AND DATA. LOCATION TO BE VERIFIED WITH TENANT
A2 TENANT ALTERNATE #2: PROVIDE MOTORIZED FOLDING PARTITION
DOOR AND FRAME SCHEDULE
D O
O R
M A
R K
DOOR FRAME
H D
W E
G R
O U
P
Fire Rating R E
M A
R K
SNOMINAL SIZE
M A
T E
R
IA
L
TYPE M
A
T E
R
IA
L
T Y
P E
G L
A S
S
DETAILS
WIDTH
PER LEAF HEIGHT HEAD JAMB SILL
1202 3' - 0" 7' - 0" (RE) A TYP. 2 TYP. 2/A9.01 8/A9.01 11/A9.01 2 -
1203 3' - 0" 7' - 0" TYP. A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 2 -
1204 3' - 0" 7' - 0" (RE) A TYP. 2 TYP. 2/A9.01 8/A9.01 11/A9.01 2 -
1205 3' - 0" 7' - 0" (RE) A TYP. 2 TYP. 2/A9.01 8/A9.01 11/A9.01 2 -
1206 3' - 0" 7' - 0" TYP. A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 2 20 MIN.
1208Da 3' - 0" 7' - 0" (RE) A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 1 20 MIN. CARD READER (BY TENANT)
1208Db 3' - 0" 7' - 0" (E) (E) (E) (E) - (E) (E) (E) - (E)
1208E 3' - 0" 7' - 0" TYP. A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 3 20 MIN. CARD READER (BY TENANT)
1210A 3' - 0" 7' - 0" (RE) A TYP. 2 TYP. 2/A9.01 8/A9.01 11/A9.01 2 -
1210B 3' - 0" 7' - 0" (E) (E) (E) (E) - (E) (E) (E) - (E)
1211 3' - 0" 7' - 0" TYP. A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 2 -
1212 3' - 0" 7' - 0" (RE) A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 1 20 MIN.
1220 3' - 0" 7' - 0" (RE) A TYP. 2 TYP. 2/A9.01 8/A9.01 11/A9.01 2 -
1221 3' - 0" 7' - 0" TYP. A TYP. 2 TYP. 2/A9.01 8/A9.01 11/A9.01 2 -
1228A 3' - 0" 7' - 0" TYP. A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 3 20 MIN. CARD READER (BY TENANT)
1228B 3' - 0" 7' - 0" (RE) A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 3 20 MIN. CARD READER (BY TENANT)
1228C 3' - 0" 7' - 0" (RE) A TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 3 20 MIN.
1229A 3' - 0" 7' - 0" TYP. B TYP. 1 - 2/A9.01 2/A9.01 11/A9.01 2 20 MIN.
1229B 4' - 0" 6' - 8" TYP. A TYP. 3 - 2/A9.01 - - 2 20 MIN.
FINISH LEGEND
(E)
(E)
32"30" 23"
30"30" 13"
TYP. OF (4)
TYP. OF (4)
505500 509
TYP. 102
32"32" 23"
TYP OF (3)
32"32" 23"
TYP OF (4)
32"36" 23"
TYP OF (4)
509 521521
A2 A2
TYP.
30"33" 13"
TYP. OF (4)
32"36" 24"32"36" 22"
TYP. OF (2)
502514503513
517500
TYP.
ETE
C-27362
RENEWAL
O
S T
T A
CI
L
E
T
AI
N
C
RDATE
F LA IC
FO
ES
N I
CHD AR
E R
IB
. HUS A
A M
R
C S
01-31-2019
ISSUE DATE: BY:
1/16" = 1'-0"GRAPHIC SCALES:
5'0 50' 0 5'
1/8" = 1'-0" 1/4" = 1'-0"
25' 0 1' 12'
1/2" = 1'-0"
0 1' 6' 0
1" = 1'-0"3/4" = 1'-0"
4' 0 1'
1 1/2" = 1'-0"
03' 2' 0
A REDUCED PRINT SCALE ACCORDINGLY
IF THIS SHEET IS NOT 30"x42" , IT IS
3" = 1'-0"
1'
Client Project Number:
Sheet
Drawn By:
Checked By:
Revit Version:
Facility
Project
Sheet Title
Scale:
Sheet
HY Architects Project number:
Revisions#
This document is the property of the Owner and is not to be used without his written permission
Architect/Engineer Of Record:_________________________________________________
SL7/28/17
100% CONSTRUCTION
DOCUMENTS
of
Issue Date:
/2
/2
:0
:2
P M
C
R e v it L o c a ls \G
S A th
F lo o r
C o n fe re n c e
R o o m
R
V T s d o s ic k .r v t
1/4" = 1'-0"
SD
SL
12TH FLOOR CONFERENCE
ROOM
INTERIOR ELEVATIONS
A5.01
1111 BROADWAY OAKLAND, CA 94607
Client Proj. #
Project Number
7/28/17
1/4" = 1'-0"
WORK ROOM 1213 - BWORK ROOM 1213 - B
1/4" = 1'-0"
CONFERENCE ROOMS - CCONFERENCE ROOMS - C
B
1/4" = 1'-0"
LUNCH ROOM 1228 - B & D
D
GENERAL NOTES
SHEET NOTES
500 4" HIGH RESILIENT BASE
502 DISHWASHER, O.F.C.I.
503 REFRIGERATOR PROVIDED BY TENANT
505 (RE) P. LAM. COUNTER AND LOWER CABINETRY
509 PROVIDE P. LAM. COUNTER AND LOWER CABINETRY
513 VENDING MACHINE PROVIDED BY TENANT
514 PROVIDE P.LAM COUNTER, UPPER AND LOWER CABINETRY, ACCESSIBLE
SINK AND GARBAGE DISPOSAL. PROVIDE INSTA-HOT AND LEAK
DETECTOR
517 42" HIGH COUNTER X 18" DEEP
518 PROVIDE P. LAM. COUNTER AND UPPER AND LOWER CABINETRY
521 MODERNFOLD MODEL #932, FULL-HEIGHT, ACOUSTICAL PARTITION -
APPROX. 29'-0" IN LENGTH, INCLUDING POCKET, TRACK AND STRUCTURAL
SUPPORT. SEE DETAIL 8/A9.02. PROVIDE NG-70 JAMB AT DOOR END.
A2 TENANT ALTERNATE #2: PROVIDE MOTORIZED FOLDING PARTITION
(E) FIRE SPRINKLER HEAD TO REMAIN
(E) RECESSED DOWNLIGHT TO REMAIN
(E) 2X4 LIGHT FIXTURE TO REMAIN
(E) SUPPLY DIFUSER TO REMAIN
(E) RETURN REGISTER TO REMAIN
(E) RETURN REGISTER TO REMOVE
(E) SUPPLY DIFUSER TO REMOVE
(RE)
(E) FIRE SPRINKLER HEAD TO REMOVE
(E) 2X4 LIGHT FIXTURE TO REMOVE
(E) 2 X 2 SUSPENDED CEILING TO REMAIN
(E) 2X4 LIGHT FIXTURE TO REMAIN
(E) 2X4 LIGHT FIXTURE TO REMOVE
(E) RECESSED DOWNLIGHT TO REMOVE
(E) SPEAKER TO REMAIN
(E) SPEAKER TO REMOVE
(E) FIRE SPEAKER TO REMAIN
(E) FIRE SPEAKER TO REMOVE
(E) FIRE STROBE TO REMAIN
(E) FIRE STROBE TO REMOVE
(E) CAMERA TO REMAIN
(E) CEILING IN GRID MICROPHONE TO REMAIN
(E) EXIT SIGN TO REMAIN
(E) EXIT SIGN TO REMOVE
DENOTES ITEM TO BE RELOCATED
(E) 2 X 2 SUSPENDED CEILING TO BE REMOVED
AREA OF NO WORK
(E) CAMERA TO REMAIN
C C.5
D D.5 E E.5 F F.5 G G.5 H H.5 J J.5 K K.5 L M
10.5
9.5
(RE)
(RE)
(RE)
(RE)
(RE) (RE) (RE)
(RE)
(RE)
(RE)
(RE)
(RE)(RE)(RE)
(RE)
(RE)
(RE)
(RE)
(RE)(RE)
ETE
C-27362
RENEWAL
O
S T
T A
CI
L
E
T
AI
N
C
RDATE
F LA IC
FO
ES
N I
CHD AR
E R
IB
. HUS A
A M
R
C S
01-31-2019
ISSUE DATE: BY:
1/16" = 1'-0"GRAPHIC SCALES:
5'0 50' 0 5'
1/8" = 1'-0" 1/4" = 1'-0"
25' 0 1' 12'
1/2" = 1'-0"
0 1' 6' 0
1" = 1'-0"3/4" = 1'-0"
4' 0 1'
1 1/2" = 1'-0"
03' 2' 0
A REDUCED PRINT SCALE ACCORDINGLY
IF THIS SHEET IS NOT 30"x42" , IT IS
3" = 1'-0"
1'
Client Project Number:
Sheet
Drawn By:
Checked By:
Revit Version:
Facility
Project
Sheet Title
Scale:
Sheet
HY Architects Project number:
Revisions#
This document is the property of the Owner and is not to be used without his written permission
Architect/Engineer Of Record:_________________________________________________
SL7/28/17
100% CONSTRUCTION
DOCUMENTS
of
Issue Date:
/2
/2
:0
:2
P M
C
R e v it L o c a ls \G
S A th
F lo o r
C o n fe re n c e
R o o m
R
V T s d o s ic k .r v t
As indicated
SD
SL
12TH FLOOR CONFERENCE
ROOM
DEMOLITION RCP
A6.01
1111 BROADWAY OAKLAND, CA 94607
Client Proj. #
Project Number
7/28/17
GENERAL NOTES
SHEET NOTES
LEGEND
1. RELOCATE (E) EXIT SIGNS, SPEAKERS, FIRE SMOKE DETECTOR & OTHER CEILING
PARAPHERNALIA AS REQ'D - VERIFY W/ BLDG ENGINEER.
2. EXISTING CEILING TILES, GRID AND ALL CEILING ACCESSORIES (LIGHT
FIXTURES, HVAC GRILLES, FLS COMPONENTS ETC.) TO REMAIN
THROUGHOUT, UNLESS REQUIRED TO BE MODIFIED BY DEMO & NEW
ROOM CONFIGURATION, OR UNLESS OTHERWISE NOTED (RRCC TO GET NEW
CEILING. NEW CEILING TILE AND GRID SHOULD MATCH EXISTING AND SHOULD
BE FROM THE SAME MANUFACTURER AS (E).
3. CONTRACTOR TO CLEAN ALL HVAC GRILLES (RETURN AND SUPPLY) TO
LIKE NEW CONDITION TO INSURE OPTIMAL PERFORMANCE. REPLACE PER
BUILDING STANDARDS AS NEEDED. RELOCATE HVAC GRILL, AS REQ'D - TO BE
DESIGN-BUILD - COORDINATE W/ BUILDING ENGINEER.
4. VERIFY EXISTING CONDITIONS IN FIELD INCLUDING LIGHT FIXTURE COUNT, EXIT
SIGNAGES, OCCUPANCY SENSORS, ETC. AND MODIFY AND REPLACE AS
NECESSARY TO MEET ALL LOCAL CODES.
5. REUSE AS MUCH EXISTING WIRE HANGERS & COMPRESSION STRUTS AS
POSSIBLE.
6. INSTALL/RELOCATE THERMOSTATS AS NECESSARY. COORDINATE LOCATION OF
THERMOSTATS WITH BUILDING ENGINEER.
7. SWITCHES AND ALL OTHER CONTROLS SHALL BE INSTALLED 36"-48" A.F.F.
8. PROVIDE REQUIRED LIFE SAFETY DEVICES THROUGHOUT SUITE PER CODE
AND BUILDING STANDARDS. WORK TO BE DESIGN-BUILD. COORDINATE WITH
BUILDING ENGINEER.
9. ISOLATE LIGHTING CIRUCUITS & REPROGRAM FOR NEWLY CREATED SPACES,
WHERE REQUIRED BY (N) CONSTRUCTION. SEE BUILDING STANDARDS FOR
CIRCUITING REQUIREMENTS.
10. REPAIR/REPLACE DAMAGED OR BROKEN CEILING TILES AS REQUIRED.
11. ASSUME (E) CLG HGT IS ±8'-10", V.I.F.
12. PROVIDE ALLOWANCE TO REPLACE 20% OF THE CEILING TILES
13. RELOCATE ILLUMINATED EXIT SIGNS PER BUILDING CODE. ILLUMINATED EXIT
SIGNS TO BE DESIGN BUILD.
14. RELOCATE FIRE ALARM DEVICES PER BUILDING CODE. FIRE ALARMS TO BE
DESIGN BUILD.
1/8" = 1'-0"
DEMOLITION RCPDEMOLITION RCP
N
C C.5 D D.5 E E.5 F F.5 G G.5 H H.5 J J.5 K K.5 L M
10.5
9.5
OFFICE
CONFERENCE
OFFICE
LUNCH ROOM
CONFERENCE
ROOM
1228A
CONFERENCE
ROOM
1228B
CONFERENCE
ROOM
1228C
OFFICE
OFFICE
1210A
OFFICE
1210B
MEETING
MEETING
OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
WORK
(RE)
(RE)
(RE)
(RE)
(RE)
(RE) (RE) (RE)
(RE)(RE)
(RE) (RE)
(RE) (RE)
(RE)
(RE)
(RE)
(RE)
(RE) (RE)
D
D
D
(E) FIRE SPRINKLER HEAD
(E) RECESSED DOWNLIGHT
(E) 2X2 LIGHT FIXTURE
(E) SUPPLY DIFUSER
(E) RETURN REGISTER
RETURN REGISTER
SUPPLY DIFUSER
(RE)
2X2 LIGHT FIXTURE
(E) 2 X 2 SUSPENDED CEILING
(E) 2X4 LIGHT FIXTURE
2X4 LIGHT FIXTURE
RECESSED DOWNLIGHT
(E) SPEAKER
SPEAKER
(E) FIRE SPEAKER
(E) FIRE STROBE
(E) CAMERA
CAMERA, MOUNT 9" FROM CEILING
(E) EXIT SIGN
RELOCATED
2 X 2 SUSPENDED CEILING TO MATCH (E)
AREA OF NO WORK
CEILING IN-GRID MICROPHONE, COORDINATE WITH TENANT
WALL TYPES
(E) CEILING HEIGHT NON-RATED PARTITION
CEILING HEIGHT NON-RATED PARTITION, SEE 4/A9.01
FULL HEIGHT 1-HR RATED WALL, SEE 15/A9.01
(E) FULL HEIGHT 1-HR RATED WALL
FULL HEIGHT NON-RATED PARTITION, SEE 10/A9.01
A
B
C
FULL HEIGHT EXTENSION NON-RATED PARTITION, SEE 3/A9.01
D
CEILING FIXTURES
(E) CEILING IN-GRID MICROPHONE
ETE
C-27362
RENEWAL
O
S T
T A
CI
L
E
T
AI
N
C
RDATE
F LA IC
FO
ES
N I
CHD AR
E R
IB
. HUS A
A M
R
C S
01-31-2019
ISSUE DATE: BY:
1/16" = 1'-0"GRAPHIC SCALES:
5'0 50' 0 5'
1/8" = 1'-0" 1/4" = 1'-0"
25' 0 1' 12'
1/2" = 1'-0"
0 1' 6' 0
1" = 1'-0"3/4" = 1'-0"
4' 0 1'
1 1/2" = 1'-0"
03' 2' 0
A REDUCED PRINT SCALE ACCORDINGLY
IF THIS SHEET IS NOT 30"x42" , IT IS
3" = 1'-0"
1'
Client Project Number:
Sheet
Drawn By:
Checked By:
Revit Version:
Facility
Project
Sheet Title
Scale:
Sheet
HY Architects Project number:
Revisions#
This document is the property of the Owner and is not to be used without his written permission
Architect/Engineer Of Record:_________________________________________________
SL7/28/17
100% CONSTRUCTION
DOCUMENTS
of
Issue Date:
/2
/2
:0
:2
P M
C
R e v it L o c a ls \G
S A th
F lo o r
C o n fe re n c e
R o o m
R
V T s d o s ic k .r v t
As indicated
SD
SL
12TH FLOOR CONFERENCE
ROOM
IMPROVEMENT RCP
A6.11
1111 BROADWAY OAKLAND, CA 94607
Client Proj. #
Project Number
7/28/17
1. RELOCATE (E) EXIT SIGNS, SPEAKERS, FIRE SMOKE DETECTOR & OTHER CEILING
PARAPHERNALIA AS REQ'D - VERIFY W/ BLDG ENGINEER.
2. EXISTING CEILING TILES, GRID AND ALL CEILING ACCESSORIES (LIGHT FIXTURES,
HVAC GRILLES, FLS COMPONENTS ETC.) TO REMAIN THROUGHOUT, UNLESS
REQUIRED TO BE MODIFIED BY DEMO & NEW ROOM CONFIGURATION, OR
UNLESS OTHERWISE NOTED (RRCC TO GET NEW CEILING. NEW CEILING TILE
AND GRID SHOULD MATCH EXISTING AND SHOULD BE FROM THE SAME
MANUFACTURER AS (E).
3. CONTRACTOR TO CLEAN ALL HVAC GRILLES (RETURN AND SUPPLY) TO LIKE NEW
CONDITION TO INSURE OPTIMAL PERFORMANCE. REPLACE PER BUILDING
STANDARDS AS NEEDED. RELOCATE HVAC GRILL, AS REQ'D - TO BE DESIGN-
BUILD - COORDINATE W/ BUILDING ENGINEER.
4. VERIFY EXISTING CONDITIONS IN FIELD INCLUDING LIGHT FIXTURE COUNT, EXIT
SIGNAGES, OCCUPANCY SENSORS, ETC. AND MODIFY AND REPLACE AS
NECESSARY TO MEET ALL LOCAL CODES.
5. REUSE AS MUCH EXISTING WIRE HANGERS & COMPRESSION STRUTS AS
POSSIBLE.
6. INSTALL/RELOCATE THERMOSTATS AS NECESSARY. COORDINATE LOCATION OF
THERMOSTATS WITH BUILDING ENGINEER.
7. SWITCHES AND ALL OTHER CONTROLS SHALL BE INSTALLED 36"-48" A.F.F.
8. PROVIDE REQUIRED LIFE SAFETY DEVICES THROUGHOUT SUITE PER CODE
AND BUILDING STANDARDS. WORK TO BE DESIGN-BUILD. COORDINATE WITH
BUILDING ENGINEER.
9. ISOLATE LIGHTING CIRCUITS & REPROGRAM FOR NEWLY CREATED SPACES,
WHERE REQUIRED BY (N) CONSTRUCTION. SEE BUILDING STANDARDS FOR
CIRCUITING REQUIREMENTS.
10. REPAIR/REPLACE DAMAGED OR BROKEN CEILING TILES AS REQUIRED.
11. ASSUME (E) CLG HGT IS ±8'-10", V.I.F.
12. PROVIDE ALLOWANCE TO REPLACE 20% OF THE CEILING TILES
13. RELOCATE ILLUMINATED EXIT SIGNS PER BUILDING CODE. ILLUMINATED EXIT
SIGNS TO BE DESIGN BUILD.
14. LOCATE FIRE SPRINKLERS PER BUILDING CODE. FIRE SPRINKLERS TO BE DESIGN
BUILD.
15. RELOCATE FIRE ALARM DEVICES PER BUILDING CODE. FIRE ALARMS TO BE
DESIGN BUILD.
GENERAL NOTES
SHEET NOTES
LEGEND
1/8" = 1'-0"
IMPROVEMENT RCPIMPROVEMENT RCP
N
HEAD
BASE
PLAN
UNDERSIDE OF (E) STRUCT.
(E) TOP RUNNER
(E) ACOUS. CLG.
MATCH (E) STUD SIZE &
THICKNESS, TYP., U.O.N. W/
SOUND INSULATION, TYP.
5/8" GYP. BD. TO UNDERSIDE OF
STRUCTURE
ACC SEALANT, TYP.
BASE & FLOORING WHERE
OCCURS, TYP.
#10 S.M.S. @ EACH STUD TYP.
TOP & BOTTOM
CONT. 20GA. BASE RUNNER,
TYP. (TOP RUNNER SIM.)
S E
E R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
0.145"∅ X 1 1/4" LOW
VELOCITY POWDER DRIVEN
PINS @ 16" O.C.
STAGGERED, TYP. U.O.N.
3" ACC. BATT INSULATION
5/8"
DOOR, W.O.
1/4" THICK CLEAR
TEMPERED GLASS
SET IN SEALANT &
GLAZING STOP
ALUMINUM FRAME
5/8"
2"
JAMB ANCHOR
5/8" GYP. BD.
1/4" THICK CLEAR
TEMPERED GLASS SET
IN SEALANT &
GLAZING STOP
ALUMINUM FRAME
SEE PLAN FOR
WALL ASSEMBLY
/8
1/2"1/2"
DIAGONAL BRACING. @ 24" O.C. TYP
- SEE 1 / -
CEILING W.O., TYP
5/8" GYP. BD. TO UNDERSIDE OF T-
BAR CEILING
20GA. MET STUDS TO MATCH (E) @
24" MAX. O.C. TYP. U.O.N. W/3 1/2"
THK. SOUND ATTENUATING BATT
INSULATION. TYP. U.O.N
0.145" DIA. X 1 1/4" LOW VELOCITY POWDER
DRIVEN PINS @ 16" O.C STAGGERED. TYP.
U.O.N
CONT. 20GA. BASE RUNNER. TYP. (TOP
RUNNER SIM.)
BASE & FLOORING WHERE OCCURS. TYP
#10 S.M.S @ EA. STUD. TYP. TOP & BOT.
CAULKING. TYP
(E) STRUCT.
S E
E R
E F
L E
C T
E D
C L G
P
L A
N
STD. S
TUD SPACIN
G
LENGTH AS REQ'D. TO
SUPPORT ITEM. (MIN.
OVER 3 STUDS U.O.N.,
TYP.)
MET. STUDS, TYP.
6" X 16 GA. STL. PL.,
SECURE TO STUDS W/ 2
- #10 X 1/2" S.M.S. @
EA. STUD. USE
ADDITIONAL PL. AS
NECESSARY
1/4" DIA. X 2" WEDGE ANCHORS
ANGLE 3" X 2" X 12" GA. X 1'-3" L.
3 #12 SELF TAPPING TEK SCREWS, TYP
2 1/2" MIN. X 1 3/8" X 16GA. BRACE
STUD @ 24 O.C. TYP.
NOTE: SIM. @ (E)
WALL-WALL BRACING
FOR BOOKCASES.
8" 8" 1" 1"
2"
TYP.
/2
U .O
.N
/8
2"
TYP.
SHIM AS REQ'D
JAMB ANCHOR, TYP.
3 5/8 20 GA. MET.STUDS
TO MEETBLDG STD, TYP.
U.O.N.
SEE DOOR SCHED.
FOR FRAME MATERIAL
DOOR (W.O.)
5/8" GYP BD (TYPE
'X' WHERE OCCURS)
1/2" EACH SIDE
HEAD
BASE
PLAN
UNDERSIDE OF (E) STRUCT.
FIRE SEALANT, TYP.
TOP RUNNER
ACOUS. CLG.
MATCH (E) STUD SIZE &
THICKNESS, TYP., U.O.N. W/
3" BATT INSULATION, TYP.
5/8" TYPE "X" GYP. BD. @
BOTH SIDES TO UNDERSIDE
OF STURCTURE
FIRE SEALANT, TYP.
BASE & FLOORING WHERE
OCCURS, TYP.
#10 S.M.S. @ EACH STUD
TYP. TOP & BOTTOM
CONT. 20GA. BASE RUNNER,
TYP. (TOP RUNNER SIM.)
S E
E R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N
0.145"Ø X 1 1/4" LOW
VELOCITY POWDER DRIVEN
PINS @ 16" O.C.
STAGGERED, TYP. U.O.N.
STUDS @ 24" O.C. MAX, TYP.
METAL STUD
16 GA. SLOTTED SLIP TRACK.
FOR FIRE RATED PARTITION
CONNECTION SEE DET.
STRUCTU…