AMEND001PRV130.pdf

PDF 8 MB Posted

Attached to
REPAIRS TO COAST GUARD HOUSING -NANTUCKET, MA
Solicitation number
HSCGG1-17-B-PRV130
Issued by

About this file

Amendment 001

View the file

Other files

File Type Posted
Abstract_of_Offers.pdf PDF
AMEND002PRV130.pdf PDF
P6376413DwgsC.pdf PDF
HSCGG117BPRV130.pdf PDF
P6376413DwgsB.pdf PDF
P6376413DwgsA.pdf PDF
P6376413Specs.pdf PDF
P6376413DwgsD.pdf PDF
WAGERATEPRV130.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

1. CONTRACT ID CODE

PAGE OF PAGES

1 2

2. AMENDMENT/MODIFICATION NO.

3. EFFECTIVE DATE

04/27/2017

4. REQUISITION/PURCHASE REQ. NO.

5. PROJECT NO. (If applicable)

6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE

Contracting Officer, CEU Providence Contracting/Inspection 475 Kilvert St. Suite 100 Warwick, Rhode Island 02886

G. J. Fortin Contracting Officer

(508) 968-6499 CEU Providence, Warwick, RI

8. NAME AND ADDRESS OF CONTRACTOR (NO., STREET, COUNTY, STATE AND ZIP CODE)

THIS AMENDMENT MUST BE ACKNOWLEDGED

9A. AMENDMENT OF SOLICITATION NO.

HSCGG1-17-B-PRV130

9B. DATED (SEE ITEM 11)

03/28/2017

10A. MODIFICATION OF CONTRACT/ORDER NO.

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

[X] The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers [ ] is extended, is not extended.

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing Items 8 and 15, and returning 001 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE REFERENCED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET

FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (SPECIFY TYPE OF MODIFICATION AND AUTHORITY)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

Solicitation HSCGG1-17-B-PRV130 identified in Block 9A, for Repairs to CG Loran Station Housing, Nantucket, MA, is amended as follows.

1. See attached amendment summary, revised window specification, and Asbestos/Radon report.

2. The due date for the proposal is not extended.

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or Print)

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

G. J. Fortin, Contracting Officer

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

15C. DATE SIGNED

16B UNITED STATES OF AMERICA

BY

(Signature of Contracting Officer)

16C. DATE SIGNED

Item No. 1

Project Drawing - Sheet G-003 – Specific Demolition Notes, Optional Bid Item #1, Note 1.1, note that reads:

“Remove and dispose of existing window system and casing in its entirety. Prepare existing opening as required for the installation of new specified hurricane impact resistant window system and associated casing and trim. Enlarge opening as required for egress window, infill opening as required to raise sill to appropriate height. Refer to demolition floor plans for “enlarge” and “infill” locations.

Change note to read, “Remove and dispose of existing window system and casing in its entirety. Prepare existing opening and ‘perform selective asbestos abatement’ as required for the installation of new specified hurricane impact resistant window system and associated casing and trim. Enlarge opening as required for egress window, infill opening as required to raise sill to appropriate height. Refer to demolition floor plans for “enlarge” and “infill” locations.

Item No. 2

Project Drawing - Sheet G-003 – General Notes Add General Note No. 6:

The existing walls and ceilings contain Asbestos, as such there will be limited selective asbestos abatement required in all units. For example, some bedroom windows will require the openings to be enlarged, walls where penetrations will need to occur, ceilings where soffits are being installed, walls where a pipe chase is installed, where electrical, plumbing or mechanical run, etc. The General Contractor shall take steps to provide an accurate accounting of all such locations and coordinate these locations with the abatement contractor. Any additional work or containment procedures required outside of the initial abatement effort will be at the contractor's expense.

Item No. 3

Project Specification Section 08 82 14 At the end of the section include the attached asbestos and radon reports for the buildings.

Item No. 4

Project Specification Section 07 31 29 – Section 3.2.3 Wall Shakes, Subsection “C” number “4” Where note reads: “Maintain weather exposure of 8 1/2 inches for 18-inch long shakes.” Change to read “Maintain weather exposure of 5 inches for 18-inch long shakes.”

Item No. 5

Project Specifications 08 5200

See attached revised Specification for Windows Section 08 52 00.

Repair Nantucket Housing 6376413

SECTION 08 52 00

ALUMINUM CLAD WOOD WINDOWS (OPTIONAL BID ITEM #1)

PART 1 GENERAL

1.1 RELATED DOCUMENTS

Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section.

1.2 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

AAMA 2605 (2005) Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels

AAMA 902 (1992; R 1999; R 2007) Voluntary Specification for Sash Balances

ASTM INTERNATIONAL (ASTM)

ASTM C 1036 (2006) Standard Specification for Flat Glass

ASTM E 1886 (2005) Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials

ASTM E 2190 Standard Specification for Insulating Glass Unit Performance and Evaluation

ASTM E 283 (2004) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM E 330 (2002; R 2010) Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference

ASTM E 514/E 514M (2009) Standard Test Method for Water Penetration and Leakage Through Masonry

ASTM E 547 (2009) Standard Test Method for Water Penetration of Exterior Windows, SECTION 08 52 00 Page 1

Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure

ASTM E 1996 Specification for performance of exterior windows, curtain walls, doors and impact protective systems impacted by windborne debris in hurricanes.

ASTM E 774 (1997) Classification of the Durability of Sealed Insulating Glass Units

INSULATING GLASS MANUFACTURERS ALLIANCE (IGMA)

IGMA TM-3000 (1997) Glazing Guidelines for Sealed Insulating Glass Units

GREEN SEAL (GS)

GS-36 (2000) Commercial Adhesives

NATIONAL FENESTRATION RATING COUNCIL (NFRC)

NFRC 100 (2004) Procedure for Determining Fenestration Product U-Factors

NATIONAL WOOD WINDOW AND DOOR ASSOCIATION (NWWDA)

AAMA/NWWDA 101/I.S.2 (1997) Voluntary Guide Specifications for Aluminum, Poly(Vinyl Chloride)(PVC) and Wood Windows and Glass Doors

U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA)

Energy Star (1992; R 2006) Energy Star Energy Efficiency Labeling System

WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)

WDMA I.S. 4 (2009) Water-Repellent Preservative Non-Pressure Treatment for Millwork

1.3 GENERAL REQUIREMENTS

1.3.1 Work Included

Work of this section includes, but is not necessarily limited to:

a. Removal of existing window systems, other accessories and existing construction as required for the proper installation and operation of the new window system.

(1) Removal or adjustment of other existing construction work as required for the proper installation and operation of the Aluminum Clad Window Systems.

b. Furnish and installation of window system in modified window openings as detailed.

c. Make field observations and take all field measurements of existing

SECTION 08 52 00 Page 2 openings and conditions prior to window fabrication. Dimensions shown on drawings are to be used as a guide and are not to be used as final measurements.

1.4 SUBMITTALS

The following shall be submitted in accordance with Section 01 33 00

SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Double Hung Aluminum Clad Wood windows;

Indicate elevations of units, full-size sections, fastenings, methods of installation and anchorage, method of glazing, locations of operating hardware, mullion details, method and material for weatherstripping, bar and muntin layouts, method of attaching insect screens , details of installation, and connections with other work.

SD-03 Product Data

Double Hung Aluminum Clad Wood windows;

Documentation for Energy Star Qualifications.

Documentation for Energy Star Qualifications.

Documentation for Energy Star Qualifications.

SD-04 Samples:

Window Sample

SD-07 Certificates

Installer Qualifications

SD-08 Manufacturer's Instructions

Double Hung Aluminum Clad Wood windows

Submit manufacturer's written instructions for installation.

SD-10 Operation and Maintenance Data

Double Hung Aluminum Clad Wood windows

Submit data package in accordance with Section 01 78 23 OPERATION

AND MAINTENANCE DATA.

1.5 QUALITY ASSURANCE

1.5.1 Installer Qualifications

Certified in writing that installer is approved by the manufacturer and has experience on at least ten projects of similar nature in past five years.

The installer shall warrant the satisfactory performance of the window installation which includes, but is not limited to, installation accessories (glazing, perimeter sealing), and anchorage as called for by

SECTION 08 52 00 Page 3 the specifications and approved shop drawings

1.5.2 Single Source Responsibility

Provide window units manufactured by one manufacturer

a. Glass and glazing for window units are required as work of this section for single source responsibility. Factory glaze units.

1.6 DELIVERY AND STORAGE

Deliver windows to site in sealed undamaged cartons or in palletized multiple units. Protect from damage, dampness and extreme temperature or humidity changes. Store under cover in well-ventilated enclosed space.

Store windows in upright position. Replace defective or damaged windows.Prime or seal wood surfaces.

1.6.1 Warranty

a. Windows shall be warranted to be free from defects in manufacturing, materials, and workmanship for a period of ten (10) years from purchase date.

b. Insulated glass shall be warranted against visible obstruction through the glass caused by a failure of the insulating glass air seal for a period of twenty (20) years from the date of original purchase.

1.7 WIND SPEED DESIGN

Wind speed for Sandwich Massachusetts: One Hundred Twenty Miles per Hour (120mph)

PART 2 PRODUCTS

2.1 DOUBLE HUNG ALUMINUM CLAD WOOD WINDOWS

Aluminum Clad Wood windows shall consist of complete units including sash, glass, frame, weatherstripping, insect screen and hardware. Window units and installation to be certified to meet the requirements of the International Building Code for glazed openings located in Wind Borne Debris Regeons.Window units shall be designed to comply withNFRC 100, ASTM E 1996, ASTM E 1886, ASTM E 330, ASTM C 1036, ASTM E 514/E 514M, and IGMA TM-3000 ASTM E 774, ASTM E 547, AAMA/NWWDA 101/I.S.2.Impact and Cycling per ASTM E 1886 with passing results for Missile Level D and Pressure Cycling of +55/-65 Psf.glazed systems (including frames and glass) shall be Energy Star qualified products as appropriate to Northern climate zone. In addition to general hardware requirements of AAMA 902, provide hardware for various window types as listed. Contractor to submit Window Sample of complete window unit

a. Manufacturers

(1) Marvin Windows and Doors, Tel: (888) 537-7828, P.O. Box 100, Warroad MN, 56763: Design is based on "Clad Ultimate Double hung Magnum Stormplus IZ3" but are not intended to be proprietary.

Products of other manufacturers listed below are acceptable if they are of the same capacity, performance, materials, sizes, and match other salient characteristics, and complies with the "Buy America Act".

SECTION 08 52 00 Page 4

(2) Other Manufacturers: In order to meet the requirements of this specification other manufacturer's custom product lines may have to be submitted to obtain the required capacity, performance, materials, sizes, and other salient characteristics listed in the system description below. Products that do not meet the requirements of these specified characteristics will not be accepted. Custom products from other manufacturers may result in additional cost to the contractor. Failure of the contractor to obtain "or equal" products from other manufacturer's shall not release the contractor from providing the specified Basis of Design product."

(a) Kolbe Windows

(b) Pella Windows

(c) Anderson Windows

2.1.1 System Description

2.1.1.1 Design and Performance Requirements

a. Window Units shall be designed to comply with 101/I.S.2-97 and

101/1.S.2/NAFS-02:

(1) Double Hung: (H-C50 up to CN 4848) (H-C35 up to CN 5436

b. Air leakage shall not exceed the following when tested at 1.57 psf according to ASTM E 283: 0.30 cfm per square foot of frame.

c. No water penetration shall occur when units are tested at the following pressure according to ASTM E 547: (H-C50 - 7.5)(H-C35 - 5.25)(F-C50 - 7.5)(TR-LC50 - 7.5) psf.

d. Window assembly shall withstand the following positive or negative uniform static air pressure difference without damage when tested according to ASTM E 330: (H-C50 - 75) (H-C35 - 52.5) (F-C50 - 75) (TR-LC50 - 75) psf.

2.1.2 Window Components

Windows shall meet the following minimum requirements of component construction;

2.1.2.1 Frame Description

a. Clear pine or finger jointed core with clear pine veneer.

(1) Kiln dried to a moisture content no greater than twelve (12) percent at the time of fabrication.

(2) Water repellent preservative treated in accordance with

WDMA I.S. 4

b. Frame thickness: 11/16 inch (17mm) head jamb, 1-11/32 inch (34mm) composite side jamb, 1-7/16 inch (37mm) sill, 8 degree bevel.

c. Frame width: 4-9/16 inch (116mm).

d. Exterior extruded aluminum clad 0.050 inch (1.3mm) thick.

SECTION 08 52 00 Page 5

2.1.2.2 Sash Description

a. Clear pine.

(1) Kiln dried to a moisture content no greater than twelve (12) percent at the time of fabrication.

(2) Water repellent preservative treated in accordance with

WDMA I.S. 4

b. Composite sash thickness: 1-9/16 inches (40mm). Corners are slot and tenoned.

c. Sash exterior extruded aluminum clad 0.045 inch (1.1mm) thick.

Operable sash tilt to interior for cleaning or removal after removal of an interior stop.

2.1.2.3 Glazing

2.1.2.3.1 Glass Type 2

a. Select quality complying with ASTM C 1036. Insulating glass SIGMA/IGCC certified to performance level CBA when tested in accordance with

ASTM E 2190.

b. Glazing method: Insulated glass (Altitude adjusted).

c. Glass type: Low E II-Argon gas (Clear).

d. Glazing seal: Silicone bedding on interior; acrylic foam tape on the exterior.

2.1.2.3.2 Glass Type 3

a. Select quality complying with ASTM C 1036. Insulating glass SIGMA/IGCC certified to performance level CBA when tested in accordance with

ASTM E 2190.

b. Glazing method: Insulated glass (Altitude adjusted).

c. Glass type: Low E II-Argon gas (Obscure).

d. Glazing seal: Silicone bedding on interior; acrylic foam tape on the exterior.

2.1.2.4 Hardware

a. Balance system: Spiral spring class five balance system and fiber filled nylon clutch. Meets or exceeds AAMA 902 requirements.

b. Jamb carrier: Vinyl extrusion with wood and aluminum inserts. Color:

White.

c. Lock: High pressure zinc die-cast cam lock and keeper. Finish: Powder coated and electro statically painted Satin Taupe.

d. Optional Sash Lift: High pressure zinc die-cast. Colors: Satin Taupe

SECTION 08 52 00 Page 6

2.1.2.5 Insect Screens

a. Factory installed full screen.

b. Screen cloth shall be 18 by 16 mesh; Charcoal fiberglass

c. Aluminum frame finish: Stone White

2.1.2.6 Simulated Divided Lites

Configuration as indicated on Window Types

a. 7/8 inch (22mm) wide (with internal spacer bars).

(1) Exterior muntins: 0.055 inch (1.4mm) thick extruded aluminum.

(2) Interior muntins: Pine. Muntins adhered to glass with double coated acrylic foam tape.

(3) Pattern: Rectangular

(4) Finish: Match sash finish.

2.2 ACCESSORIES

2.2.1 Adhesives

Comply with applicable regulations regarding toxic and hazardous materials, GS-36 and as specified in Section 07 92 00 JOINT SEALANTS.

2.2.2 Weather Striping

Operating Units: Continuous leaf weather strip at head jamb parting stop;

foam filled bulb weather strip along vertical sash edge; bulb weather strip at bottom rail. Color: Beige. Jamb weather strip.

2.2.3 Installation Flange

a. Head jamb flange/drip cap, side jamb and sill flange, Head nailing flange with drip cap not designed to replace proper flashing. Install on windows that do not indicate the manufacturer's aluminum extruded trim to be utilized.

2.3 FINISH, EXTERIOR AND INTERIOR

2.3.1 Paint

Furnish windows with factory-primed and finished interior surfaces. Color, White / Finish, Semi -Gloss

2.3.2 Aluminum Cladding

Exterior Casing shall be extruded aluminum clad, 0.050 inch (1.3mm) thick.

2.3.2.1 Aluminum Finish

Factory finish fluoropolymer modified acrylic topcoat applied over primer.

Color, Stone white. Conform to AAMA 2605.

SECTION 08 52 00 Page 7

PART 3 EXECUTION

3.1 INSTALLATION

3.1.1 Aluminum Clad Wood Windows

a. Verification of Conditions: Before installation, verify openings are plumb, square, and of proper dimension. Report frame defects or unsuitable conditions to the General Contractor before proceeding.

b. Acceptance of Conditions: Beginning of installation confirms acceptance of existing conditions.

c. Install in accordance with the approved installation instructions and reviewed shop drawings.. Securely anchor windows in place. Use nailing flanges as supplied by window manufacturer and pre-attached to window frame. Install and seal windows in a manner that will prevent entrance of water and wind.Install sealant and related backing materials at perimeter of unit or assembly in accordance with Section 07 92 00 Joint Sealants. Do not use expansive foam sealant.

3.2 ADJUSTMENTS

Make final adjustment for proper operation of ventilating unit after glazing. Make adjustments to operating sash or ventilators to assure smooth operation. Units shall be weathertight when locked closed. Verify products are properly installed, connected, and adjusted.

3.3 CLEANING

Clean windows on both exterior and interior in accordance with manufacturer's recommendations.Remove visible labels and adhesive residue from glass according to manufacturer's instructions.

3.4 PROTECTING INSTALLED CONSTRUCTION

Protect windows from damage by chemicals, solvents, paint, or other construction operations that may cause damage.

-- End of Section --

SECTION 08 52 00 Page 8

SanAir Technologies LaboratorySanAir Technologies Laboratory

Analysis Report prepared for

Environmental Consulting & Management Inc

Report Date: 9/21/2016 Project Name: USCG Housing - LS1 Project #: 160439 SanAir ID#: 16033389

804.897.1177 www.sanair.com804.897.1177 www.sanair.com

SanAir Technologies Laboratory, Inc.

1551 Oakbridge Drive, Suite B, Powhatan, VA 23139

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

September 21, 2016

SanAir ID # 16033389 Project Name: USCG Housing - LS1 Project Number: 160439

Dear Michael A. Berube, We at SanAir would like to thank you for the work you recently submitted. The 17 sample(s) were received on Thursday, September 15, 2016 via FedEx. The final report(s) is enclosed for the following sample(s): LS1-01A, LS1-02A, LS1-03A, LS1-04A, LS1-05A, LS1-06A, LS1-07A, LS1-08A, LS1-09A, LS1-010A, LS1-011A, LS1-011B, LS1-011C, LS1-012A, LS1-012B, LS1-012C, LS1-013A.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

17 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS1

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/21/2016 3:56:02 PM

Vaughan, Nathaniel

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-01A / 16033389-001 Beige 96% Other 4% Chrysotile Floor Tile Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-02A / 16033389-002 Black 97% Other 3% Chrysotile Mastic Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-03A / 16033389-003 Grey 96% Other 4% Chrysotile Floor Tile Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-04A / 16033389-004 Black 97% Other 3% Chrysotile Mastic Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-05A / 16033389-005 Beige 98% Other 2% Chrysotile Floor Tile Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-06A / 16033389-006 Black 97% Other 3% Chrysotile Mastic Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-07A / 16033389-007 Tan 95% Other 5% Chrysotile Floor Tile Non-Fibrous

Heterogeneous

16033389 SanAir ID Number

FINAL REPORT

Certification

Analyst: Approved Signatory:

Analysis Date: 9/21/2016 Date: 9/21/2016 Page 3 of 8

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS1

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/21/2016 3:56:02 PM

Vaughan, Nathaniel

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-08A / 16033389-008 Black 97% Other 3% Chrysotile Mastic Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-09A / 16033389-009 Black 100% Other None Detected Cove Base Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-010A / 16033389-010 Yellow 100% Other None Detected Adhesive Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-011A / 16033389-011 Beige 98% Other 2% Chrysotile Joint Compound Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-011B / 16033389-012 Not Analyzed Joint Compound

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-011C / 16033389-013 Not Analyzed Joint Compound

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-012A / 16033389-014 White 4% Cellulose 96% Other None Detected Sheetrock Non-Fibrous

Heterogeneous

16033389 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 9/21/2016 Date: 9/21/2016 Page 4 of 8

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS1

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/21/2016 3:56:02 PM

Vaughan, Nathaniel

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-012B / 16033389-015 White 4% Cellulose 96% Other None Detected Sheetrock Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-012C / 16033389-016 White 4% Cellulose 96% Other None Detected Sheetrock Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1-013A / 16033389-017 White 100% Other None Detected Sink Anti-Condensate Non-Fibrous

Heterogeneous

16033389 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 9/21/2016 Date: 9/21/2016 Page 5 of 8

Disclaimer

The final report cannot be reproduced, except in full, without written authorization from SanAir.

Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

NY ELAP lab ID 11983 prepared for

Environmental Consulting & Management Inc

Report Date: 9/22/2016 Project Name: USCG Housing - LS2 Project #: 160439 SanAir ID#: 16033392

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

September 22, 2016

SanAir ID # 16033392 Project Name: USCG Housing - LS2 Project Number: 160439

Dear Michael A. Berube, We at SanAir would like to thank you for the work you recently submitted. The 12 sample(s) were received on Thursday, September 15, 2016 via FedEx. The final report(s) is enclosed for the following sample(s): LS2-01A, LS2-02A, LS2-03A, LS2-04A, LS2-05A, LS2-05B, LS2-05C, LS2-06A, LS2-06B, LS2-06C, LS2-07A, LS2-08A.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

12 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS2

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 1:47:38 PM

Toth, Elizabeth

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-01A / 16033392-001 Green 100% Other None Detected 12x12 FT Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-02A / 16033392-002 Yellow 100% Other None Detected Mastic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-03A / 16033392-003 Beige 100% Other None Detected 12x12 FT Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-04A / 16033392-004 Black 4% Cellulose 94% Other 2% Chrysotile Mastic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-05A / 16033392-005 White 100% Other None Detected Joint Compound Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-05B / 16033392-006 White 98% Other 2% Chrysotile Joint Compound Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-05C / 16033392-007 Not Analyzed Joint Compound

16033392 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 9/22/2016 Date: 9/22/2016 Page 3 of 6

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS2

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 1:47:38 PM

Toth, Elizabeth

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-06A / 16033392-008 Off-White 3% Cellulose 97% Other None Detected Sheetrock Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-06B / 16033392-009 Off-White 5% Cellulose 95% Other None Detected Sheetrock Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-06C / 16033392-010 Off-White 5% Cellulose 95% Other None Detected Sheetrock Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-07A / 16033392-011 Grey 20% Glass 77% Other None Detected TSI Non-Fibrous 3% Min. Wool

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS2-08A / 16033392-012 Various 3% Cellulose 82% Other None Detected Vermiculite Non-Fibrous 15% Synthetic

Heterogeneous

16033392 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 9/22/2016 Date: 9/22/2016 Page 4 of 6 accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

prepared for

Environmental Consulting & Management Inc

Report Date: 9/22/2016 Project Name: USCG Housing - LSX 1/2 Project #: 160439 SanAir ID#: 16033427

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

September 22, 2016

SanAir ID # 16033427 Project Name: USCG Housing - LSX 1/2 Project Number: 160439

Dear Michael A. Berube, We at SanAir would like to thank you for the work you recently submitted. The 2 sample(s) were received on Thursday, September 15, 2016 via FedEx. The final report(s) is enclosed for the following sample(s): LS1X1A, LS1X1B.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

2 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LSX 1/2

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 2:16:07 PM

Tallert, Jonathan

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1X1A / 16033427-001 Black 60% Cellulose 40% Other None Detected Siding Paper Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS1X1B / 16033427-002 Black 60% Cellulose 40% Other None Detected Siding Paper Fibrous

Homogeneous

16033427 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 9/22/2016 Date: 9/22/2016 Page 3 of 5 accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

prepared for

Environmental Consulting & Management Inc

Report Date: 9/22/2016 Project Name: USCG Housing - LS3 Project #: 160439 SanAir ID#: 16033394

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

September 22, 2016

SanAir ID # 16033394 Project Name: USCG Housing - LS3 Project Number: 160439

Dear Michael A. Berube, We at SanAir would like to thank you for the work you recently submitted. The 17 sample(s) were received on Thursday, September 15, 2016 via FedEx. The final report(s) is enclosed for the following sample(s): LS3-01A, LS3-02A, LS3-03A, LS3-04A, LS3-05A, LS3-06A, LS3-07A, LS3-08A, LS3-08B, LS3-08C, LS3-09A, LS3-09B, LS3-09C, LS3-010A, LS3-011A, LS3-012A, LS3-013A.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

2 sample(s) in Discrepancy w/ COC condition 15 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS3

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 4:44:08 PM

Pisula, Nicholas

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-01A / 16033394-001 Grey 20% Cellulose 80% Other None Detected Linoleum, Linoleum Non-Fibrous

Homogeneous LS3-01A / 16033394-001 Tan 100% Other None Detected Linoleum, Mastic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-02A / 16033394-002 Tan 20% Cellulose 80% Other None Detected Linoleum Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-03A / 16033394-003 Grey 96% Other 4% Chrysotile Leveler, Floor Tile Non-Fibrous

Homogeneous LS3-03A / 16033394-003 Tan 100% Other None Detected Leveler, Mastic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-04A / 16033394-004 Green 97% Other 3% Chrysotile Flooring, Floor Tile Non-Fibrous

Homogeneous LS3-04A / 16033394-004 Tan 20% Cellulose 80% Other None Detected Flooring, Linoleum Non-Fibrous

Homogeneous LS3-04A / 16033394-004 Tan 100% Other None Detected Flooring, Mastic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-05A / 16033394-005 Grey 97% Other 3% Chrysotile Flooring Non-Fibrous

Homogeneous

16033394 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 9/22/2016 Date: 9/22/2016 Page 3 of 8

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS3

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 4:44:08 PM

Pisula, Nicholas

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-06A / 16033394-006 Black 98% Other 2% Chrysotile Mastic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-07A / 16033394-007 Beige 100% Other None Detected Sink Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-08A / 16033394-008 Grey 98% Other 2% Chrysotile Joint Compound Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-08B / 16033394-009 Not Analyzed Joint Compound

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-08C / 16033394-010 Not Analyzed Joint Compound

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-09A / 16033394-011 Grey 5% Cellulose 95% Other None Detected Sheetrock Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-09B / 16033394-012 Grey 98% Other 2% Chrysotile Sheetrock, Joint Compound Non-Fibrous

Homogeneous

16033394 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 9/22/2016 Date: 9/22/2016 Page 4 of 8

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS3

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 4:44:08 PM

Pisula, Nicholas

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-09C / 16033394-013 Not Analyzed Sheetrock

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-010A / 16033394-014 Grey 97% Other 3% Chrysotile FT Under Carpet Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-011A / 16033394-015 Black 98% Other 2% Chrysotile Mastic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-012A / 16033394-016 Grey 10% Min. Wool 90% Other None Detected TSI In Attic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3-013A / 16033394-017 Tan 100% Other None Detected Vermiculite Non-Fibrous

Homogeneous

16033394 SanAir ID Number

FINAL REPORT

Certification

Analysis Date: 9/22/2016 Date: 9/22/2016 Page 5 of 8 accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

prepared for

Environmental Consulting & Management Inc

Report Date: 9/22/2016 Project Name: USCG Housing - LS4 Project #: 160439 SanAir ID#: 16033381

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

September 22, 2016

SanAir ID # 16033381 Project Name: USCG Housing - LS4 Project Number: 160439

Dear James Gallagher, We at SanAir would like to thank you for the work you recently submitted. The 12 sample(s) were received on Thursday, September 15, 2016 via FedEx. The final report(s) is enclosed for the following sample(s): LS4-01A, LS4-02A, LS4-03A, LS4-04A, LS4-05A, LS4-06A, LS4-06B, LS4-06C, LS4-07A, LS4-07B, LS4-07C, LS4-08A.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS4

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 4:45:59 PM

Childress, Susan

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-01A / 16033381-001 Gold 100% Other < 1% Tremolite Vermiculite Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-02A / 16033381-002 Grey 96% Other 4% Chrysotile 9"x9" Tile Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-03A / 16033381-003 Black 98% Other 2% Chrysotile Mastic Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-04A / 16033381-004 Grey 30% Glass 70% Other < 1% Chrysotile TSI Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-05A / 16033381-005 Off-White 10% Cellulose 90% Other None Detected Sink Anti-Condensate Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-06A / 16033381-006 Beige 98% Other 2% Chrysotile Joint Compound Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-06B / 16033381-007 Not Analyzed Joint Compound

16033381 SanAir ID Number

FINAL REPORT

Certification

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LS4

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 4:45:59 PM

Childress, Susan

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-06C / 16033381-008 Not Analyzed Joint Compound

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-07A / 16033381-009 Off-White < 1% Cellulose 100% Other None Detected Sheetrock Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-07B / 16033381-010 Off-White < 1% Cellulose 100% Other None Detected Sheetrock Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-07C / 16033381-011 Off-White < 1% Cellulose 100% Other None Detected Sheetrock, Sheetrock Non-Fibrous

Homogeneous LS4-07C / 16033381-011 Beige 98% Other 2% Chrysotile Sheetrock, Joint Compound Non-Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS4-08A / 16033381-012 Black 8% Cellulose 92% Other None Detected Sealant Non-Fibrous

Homogeneous

16033381 SanAir ID Number

FINAL REPORT

Certification accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

prepared for

Environmental Consulting & Management Inc

Report Date: 9/22/2016 Project Name: USCG Housing -

LSX3/ 4

Project #: 160439 SanAir ID#: 16033404

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

September 22, 2016

SanAir ID # 16033404 Project Name: USCG Housing - LSX3/ 4 Project Number: 160439

Dear Michael A. Berube, We at SanAir would like to thank you for the work you recently submitted. The 6 sample(s) were received on Thursday, September 15, 2016 via FedEx. The final report(s) is enclosed for the following sample(s): LS3X 1A, LS3X 1B, LS3X 1C, LS3X 2, LS3X 3, LS3X 4.

These results only pertain to this job and should not be used in the interpretation of any other job.

This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information sample conditions:

6 sample(s) in Good condition

804.897.1177 Toll Free: 888.895.1177 Fax: 804.897.0070

Web: http://www.sanair.com E-mail: iaq@sanair.com

Name:

Address:

Environmental Consulting & Management Inc 50 Kickemuit Ave Bristol, RI 02809

Project Number:

P.O. Number:

Project Name:

160439

USCG Housing - LSX3/ 4

Collected Date:

Received Date:

Report Date:

Analyst:

8/31/2016

9/15/2016 10:00:00 AM

9/22/2016 2:16:41 PM

Pisula, Nicholas

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components Asbestos

SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3X 1A / 16033404-001 Black 7% Glass 90% Other None Detected Asphalt Shingles Non-Fibrous 3% Cellulose

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3X 1B / 16033404-002 Black 20% Cellulose 80% Other None Detected Asphalt Shingles Non-Fibrous

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3X 1C / 16033404-003 Black 7% Glass 90% Other None Detected Asphalt Shingles Non-Fibrous 3% Cellulose

Heterogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3X 2 / 16033404-004 Black 50% Cellulose 50% Other None Detected Tar Paper Fibrous

Homogeneous

Stereoscopic Components Asbestos SanAir ID / Description Appearance % Fibrous % Non-Fibrous Fibers LS3X 3 /…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .