HSCG85-17-Q-P45120

USCGC FRANK DREW REPAIRS

Amendment 0001

1. QUESTION: Item 20 – Paragraph 1.1 requires renewal of (2) 8” Simplex

Strainers and (1) 3” Duplex Strainer but paragraph 1.2 , GFP only has (1) 3”

Duplex Strainer. Please confirm the GFP quantity and the contractor has to replace the (2) Simplex Strainers.

ANSWER: The KTR will need to replace the Simplex strainers. The simplex strainers should be relatively available and inexpensive. We typically only provide the items that are long lead time etc.