PRICING_SCHEDULE-COBB-ATTACHMENT_1-REV-AMEND_0002.xlsx
XLSX spreadsheet 17 KB Posted
- Solicitation number
- HSCG85-16-Q-P45T58
About this file
AMENDMENT NO 0002 Revised Pricing Schedule -Attachment 1
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMEND_NO_0002_-P45T58.pdf | ||
| NON_DISCLOSURE_AGREEMENT-ATTACHMENT_6.docx | DOCX document | |
| AMEND_NO_01_-P45T58.pdf | ||
| RFQ-P45T58-GEORGE_COBB-FINAL-AMEND_01.docx | DOCX document | |
| RFQ-P45T58-GEORGE_COBB-FINAL.docx | DOCX document | |
| RFQ-P45T58-GEORGE_COBB-FINAL.docx | DOCX document | |
| SECTION_B_PRICING-ATTACHMENT_1.xlsx | XLSX spreadsheet | |
| GOVERNMENT_PROPERTY_REPORT-ATTACHMENT_3.docx | DOCX document | |
| WORK_SPECIFICATIONS-ATTACHMENT_2.pdf | ||
| Past_Performance_Information_Form-ATTACHMENT_4.docx | DOCX document | |
| Request_for_Clarification-ATTACHMENT_5.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRICING SCHEDULE
| PRICING SCHEDULE FOR: |
| USCGC GEORGE COBB (WLM-175) DRYDOCK AVAILABILITY FY2016 |
| ITEM | DESCRIPTION | QTY | UNIT | UNIT PRICE | EXTENDED PRICE |
| D-001 | Hull Plating (U/W Body), Inspect | 1 | JOB | ||
| D-002 | Appendages (U/W), Leak Test | 1 | JOB | ||
| D-003 | Appendages (U/W) - Internal, Preserve | 1 | JOB | ||
| D-004 | Tanks (MP Fuel Service), Clean and Inspect | 1 | JOB | ||
| D-005 | Tanks (Hydraulic Oil Stowage and Service), Clean and Inspect | 1 | JOB | ||
| D-006 | Tanks (Potable Water), Clean and Inspect | 1 | JOB | ||
| D-007 | Tanks (Lube Oil), Clean and Inspect | 1 | JOB | ||
| D-008 | Tanks (Ballast), Clean and Inspect | 1 | JOB | ||
| D-009 | Voids (Accessible), Clean and Inspect | 1 | JOB | ||
| D-010 | Tanks (Dirty Oil and Waste), Clean and Inspect | 1 | JOB | ||
| O-011 | Z-Drive Propulsion Units, Overhaul | 1 | JOB | ||
| O-012 | Z-Drive Propulsion Unit, Renew (Drydock) | 1 | JOB | ||
| D-013 | SW Heat Exchangers, Clean, Inspect and Hydro | 1 | JOB | ||
| D-014 | Fathometer Transducer, General Maintenance | 1 | JOB | ||
| D-015 | Underwater (Speed) Log Transducer(s), Overhaul | 1 | JOB | ||
| D-016 | Sea Valves and Waster Pieces, Overhaul or Renew | 1 | JOB | ||
| D-017 | Sea Strainers - Duplex (All Sizes), Overhaul | 1 | JOB | ||
| O-018 | Sea Bay, Preserve - Partial | 1 | JOB | ||
| D-019 | Sea Bay, Clean and Inspect | 1 | JOB | ||
| O-020 | Sea Bay, Preserve 100% | 1 | JOB | ||
| D-021 | Compressed Air Receivers and System Valves (All), Clean, Inspect, Hydro and Lift | 1 | JOB | ||
| D-022 | Thruster Unit (General), Overhaul | 1 | JOB | ||
| D-023 | Hydraulic Chain Stoppers, Inspect and Test | 1 | JOB | ||
| D-024 | Anchor Chain(s) and Ground Tackle, Inspect and Repair | 1 | JOB | ||
| D-025 | Towing Bitts, Chocks, and Fairleads, Inspect and Test | 1 | JOB | ||
| D-026 | Grey Water Holding Tank(s), Clean and Inspect | 1 | JOB | ||
| D-027 | Sewage Holding Tank(s), Clean and Inspect | 1 | JOB | ||
| D-028 | Sewage Piping, Clean and Flush | 1 | JOB | ||
| O-029 | Tanks (Ballast), Preserve “100%” | 1 | JOB | ||
| O-030 | Tanks (Ballast), Preserve “Partial” | 1 | JOB | ||
| D-031 | Chain Locker, Preserve 100% | 1 | JOB | ||
| O-032 | Tanks (Dirty Oil and Waste), Preserve “100%” | 1 | JOB | ||
| O-033 | Tanks (Dirty Oil and Waste), Preserve “Partial” | 1 | JOB | ||
| O-034 | Tanks (Grey Water Holding), Preserve “100%” | 1 | JOB | ||
| O-035 | Tanks (Grey Water Holding), Preserve “Partial” | 1 | JOB | ||
| O-036 | Tanks (Sewage Holding), Preserve “100%” | 1 | JOB | ||
| O-037 | Tanks (Sewage Holding), Preserve “Partial” | 1 | JOB | ||
| O-038 | Tanks (Sewage Vacuum Collection), Preserve “100%” | 1 | JOB | ||
| O-039 | Tanks (Sewage Vacuum Collection), Preserve “Partial” | 1 | JOB | ||
| O-040 | Accessible Void(s), Preserve “Partial” | 1 | JOB |
ATTACHMENT 1
| ITEM | DESCRIPTION | QTY | UNIT | UNIT PRICE | EXTENDED PRICE |
| O-041 | Tanks (Potable Water), Preserve “100%” | 1 | JOB | ||
| O-042 | Tanks (Potable Water), Preserve “Partial” | 1 | JOB | ||
| O-043 | U/W Body, Preserve (Partial - Condition A) | 1 | JOB | ||
| O-044 | U/W Body, Preserve (Partial - Condition B) | 1 | JOB | ||
| O-045 | U/W Body, Preserve (Partial - Condition C) | 1 | JOB | ||
| D-046 | Cathodic Protection / Zinc Anodes, Renew WLM-175 | 1 | JOB | ||
| D-047 | Drydock | 1 | JOB | ||
| D-048 | Temporary Services, Provide - Cutter | 1 | JOB | ||
| D-049 | Sea Trial Performance, Support, Provide | 1 | JOB | ||
| D-050 | Main Mast, Preserve - Partial | 1 | JOB | ||
| D-051 | Compartment Insulation (General), Renew | 1 | JOB | ||
| D-052 | Buoy Deck Cleats, Modify | 1 | JOB | ||
| D-053 | Hull Plating (U/W Body), Ultrasonic Testing | 1 | JOB | ||
| D-054 | Tanks (MP Fuel Stowage and Overflow), Clean and Inspect | 1 | JOB | ||
| O-055 | Hull Plating Freeboard (Buoy Port Areas), Preserve | 1 | JOB | ||
| O-056 | Hull Plating Freeboard, Preserve - Partial | 1 | JOB | ||
| O-057 | Hull Plating Freeboard, Preserve “100%” | 1 | JOB | ||
| D-058 | Equipment Foundations, Preserve | 1 | JOB | ||
| D-059 | Internal Fume-Tight Joiner Door and Frame, Renew | 1 | JOB | ||
| D-060 | Deck Drain & Sounding Caps, Repair | 1 | JOB | ||
| D-061 | Sewage Vent Pipe, Renew | 1 | JOB | ||
| D-062 | Vent Duct Insulation, Renew | 1 | JOB | ||
| D-063 | Heat Pump 5 Bulkhead, Preserve | 1 | JOB | ||
| D-064 | Searchlights, Repair | 1 | JOB | ||
| O-065 | U/W Body, Preserve (100%) | 1 | JOB | ||
| O-00A | Composite Labor Rate | 810 | Hour | ||
| D-00B | GFP Report | EA | NSP | NSP | |
| O-00Z | Laydays | 5 | Day | ||
| Total Price of Definite Items | |||||
| Total Price of Option Items | |||||
| Total Price of Definite and Optional Items | |||||
| ATTACHMENT 1 |
Sheet2
Sheet3
File details come from the government source that posted it. Updated .